notification_type|material|defect_date|priority|notification_origin|customer_name|region|notification_desc|notification_status|root_cause|damage_group_desc|damage_desc|object_part_group_desc_1|object_part_desc_1|cause_group_desc|cause_desc
ZF|P6000066700|15/09/2011|priority 1 |Q3|HOUSTON STOCKING V2|Unknown|Missing HC in SCM OKONO|NOCO ATCO NOTE|Human error  process not maintained|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
Q3|7105128|10/10/2003|priority 2 |Q3|TOTAL|Unknown|GIR-125 SCM S/N 19P no comm SEM B|NOCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7102643|13/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 14 ÅsgA R1-H LP Leak in bottom Acc.|NOCO ATCO NOPT NOTI|Due to overpressurizing on WOCS LP-syste|102-Hydraulic|Accumulators|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Damages
ZB|P6000039844|11/10/2018|priority 4 |Q1|Unknown|Unknown|SCM #6 due for delivery|NOTI OSTS NOPR|Unknown|Project|Project Requested Unfinished shipment|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Second tier supplier issue
Q3|7101463|25/06/2002|priority 3 |Q3|Unknown|Unknown|DHI-failure|NOCO NOPT ATCO NOTI|Unknown|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q1|7101172|26/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 20 GFA D-1H PT Func AWV malfunction|NOCO NOTI NOPT|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|P7000016420|05/09/2011|priority 1 |Q3|Unknown|Unknown|Bucha -Revestimento não Conforme- P55/09|ATCO NOCO NOPT NOTE|REVESTIMENTO|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|QA/QS/QI Related|Goods Receiving Inspection error
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 48 ÅsgB J-3H SEM A shortcircuit|NOTI NOCO NOPT|Unknown|103-Electrical|SEM Powersupply|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
ZF|P6000037215|07/06/2011|priority 3 |Q3|ENGIE|NORTH SEA|Short circuit of low amp board to earth|NOCO ATCO NOPT NOTE|Change in procedure|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Other Electric Products|FMC Engineering related |Procedure error
ZE|P6000084906|12/09/2015|priority 2 |Q3|Unknown|Unknown|Plastic cover found inside new SCM|ATCO NOTE NOCO|SCM not thoroughly checked before closed|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Other hydraulic components|QA/QS/QI Related|Operator error
ZF|100030542|17/08/2007|priority 3 |Q3|Unknown|Unknown|Drawing errors found at Final Inspection|NOPT ATCO NOCO NOTE|Product revision|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|100016110|01/05/2001|priority Unknown|Q3|Unknown|Unknown|Damaged shipping container upon reciept|NOCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100035118|10/02/2005|priority Unknown|Q3|ENFIELD|Unknown|SCM prod # 5  failure of SEM A|NOPT NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7103233|13/12/2004|priority 3 |Q3|Unknown|Unknown|CSA factory audit of SCMs  4 findings|NOCO NOPT ATCO NOTE|No manual to comply with CSA|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes|Miscellaneous
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM S/N 7 I-1H GFA AI card malfunct.SEMB|NOPT ATCO NOTI NOCO|AI-card on SEM B|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
Q3|7104670|24/02/2000|priority 4 |Q3|Unknown|Unknown|All SCMs to have hyd. flow restrictors|NOTI NOCO NOPT ATCO|Instructions from system engineering|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q2|7105128|Unknown|priority 3 |Q2|Unknown|Unknown|SCM P 01|NOPT NOCO NOTE|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000110991|20/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extended test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000068912|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100015538|27/02/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|ATCO NOPT NOCO NOTE|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000064909|19/01/2012|priority 2 |Q3|TOTAL|Unknown|Temp sens indicates to high temp (SCM)|NOTE NOCO NOPT ATCO|Follow-up in SN 300307969|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|P6000050867|26/10/2010|priority 1 |Q3|Unknown|Unknown|FAT stopped due to software problems|NOCO NOPT NOTE|FMC Engineering related: Engineering Err|Test Related |OBS-Function|SS - Controls -Computer system software|Electrical solution SW|FMC Engineering related |Engineering Error
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|Unknown|Trafo problems on Agbami S/N 27|NOPT NOTE NOCO ATCO|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|ATCO NOPT NOTE NOCO|PSM not followed  short mob time|Assembly/Test Related |Do Not Use|FKS Quality system issues|Resource Management|FMC Assy |Missing Operation
ZF|100048038|16/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|batch missing|NOTE NOCO NOPT|New requirements|Marking |No Marking|Common/Misc - Fasteners - Imperial|Screw|FMC Engineering related |Engineering Error
ZF|7103234|11/05/2007|priority 2 |Q3|Unknown|Unknown|Communication missing|NOTE NOPT NOCO|See SN 300160640|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |QN Cancelled
ZF|P6000104116|13/05/2014|priority 3 |Q3|Unknown|Unknown|Mangler risteprofil til DIU|ATCO NOTE NOPT NOCO|No procedure fault Lack of OPRexperience|Documentation |Procedure / Process Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |No Non-Compliance
ZF|P6000101955|18/02/2014|priority 3 |Q3|Unknown|Unknown|Low voltage during EEtest|NOCO NOTE NOPT ATCO|Minor impedance-increase  Faston contact|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Other causes/damage |QN Cancelled
ZF|100037967|20/01/2009|priority 1 |Q3|BP|Unknown|B18 MCM N1 - lost comunication to SEM A|NOCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 04|NOPT NOTE NOCO ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000104111|10/06/2014|priority 4 |Q3|Unknown|Unknown|Damage base plate|NOTE ATCO NOPT NOCO|Damaged during dissassembly|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Assy |Operator Error
Q3|3812476|04/07/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM Press. transm. faults well C4-H|NOPT NOCO NOTI|Refer to QN200008584|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
ZF|100031193|27/01/2004|priority 2 |Q3|PETROBRAS|Unknown|THE DRAINHOLE IS TOO BIG|NOTE NOCO ATCO NOPT|Drain hole too large|Assembly / Test related |Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Design Specification/Drawing error
ZF|100056443|29/11/2018|priority 2 |Q3|Unknown|Unknown|SCM B side DHI Card in-operational|NOPT NOCO ATCO NOTE|Unknown|Electrical |Component Failure|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
Q3|7102643|27/04/2000|priority 3 |Q3|Unknown|Unknown|Function PT for AWV not working (R-1-H)|NOTI NOPT ATCO NOCO|Refer to QN 200003653|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|100020562|27/10/2004|priority 3 |Q3|Unknown|Unknown|SCM marking labels are peeling off|NOTE NOPT ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7105128|04/08/2000|priority Unknown|Q3|Unknown|Unknown|SCM P 01|NOCO ATCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000088604|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100048038|30/11/2010|priority 2 |Q3|CHEVRON|WEST AFRICA|Class 1 ECN 6083510|NOCO NOTE ATCO NOPT|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000024191|28/09/2012|priority 2 |Q3|Unknown|Unknown|DPT B values|NOTE NOCO ATCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000116166|01/06/2016|priority 3 |Q3|Unknown|Unknown|Bladder in outercan bursded|NOTE ATCO NOPT NOCO|Silicon bladder changed|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Damaged during assembly
ZF|P6000079984|07/02/2013|priority 1 |Q3|Unknown|Unknown|Wrong SEM supply voltage reading at ST|NOTE NOCO ATCO|Lack of calibr. procedure  ref NRB text|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Procedure error
ZF|P6000088614|25/06/2015|priority 3 |Q3|Unknown|Unknown|Wedge disc holes are too small|NOPT ATCO NOTE NOCO|Holes on part not acc. to DWG|Machining Related |OBS-Hole Size Error|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Vendor related |Specification not followed
ZF|P6000073687|25/06/2012|priority 3 |Q3|Unknown|Unknown|Missing info on GA dwg.|ATCO NOTE NOCO|Missing info on GA dwg.ZE QN:200269754|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|100048038|10/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|SILICONE CONTAMINATION|ATCO NOPT NOTE NOCO|SILICON CONTAMINATION|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Packaging & Storage
ZB|100020562|07/06/2006|priority 2 |Q1|BP|GOM|PT reading for SCSSV B below acceptable|NOTE NOCO NOPT ATCO|Sensors failed in Control Module|Damage |Wear & Tear|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Vendor related |Component error
ZF|100017278|18/03/2004|priority 3 |Q3|STATOIL|NORTH SEA|DHI-109 problemer|ATCO NOCO NOPT NOTE|Lack of updated test procedure|Design |Do Not Use|Subsea Control Module (SCM) Electrical|DHI PCBs|FMC Manufacturing related |Do Not Use
Q3|7102643|Unknown|priority 3 |Q3|Unknown|Unknown|Leak from SCM accumulator offshore|NOCO NOTI NOPT ATCO|Test error (accumulator over pressured)|102-Hydraulic|Accumulators|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Service
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrade Marlim SCM 06-ALFA to 06-GAMA|ATCO NOTI NOPT NOCO|Wrong material|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|100064910|25/03/2015|priority 3 |Q3|Unknown|Unknown|Wrong bolts in BOM for SEM el-can.|ATCO NOTE NOCO|Incorrect part in BOM/DBI|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P7000024900|15/08/2013|priority 1 |Q3|Unknown|Unknown|SOLICITAÇÃO DE CONCESSÃO|NOPT ATCO NOTE NOCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|100037966|27/06/2012|priority 2 |Q3|Unknown|Unknown|SCM P9  HFT  PRD voltage clarification|NOTE NOPT NOCO|Typo in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000039672|08/08/2014|priority 1 |Q3|Unknown|Unknown|Vazamento no Manifold Block|ATCO NOCO NOTE NOPT|FMC Dunfermline|124086 PARNOX IND E COM DE ARTIGOS IND L|Assembly Related |OBS-imension (tolerance)|Common/Misc - Fasteners - Metric|Hydraulic Manifold / Adapter Plate|Intercompany|Final Inspection Error
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Bytting av PT'er.|NOCO NOTE ATCO NOPT|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-016: RAM Warning Error|NOCO NOTE|Error Message|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZE|7100320|12/06/2015|priority 3 |Q3|PETROBRAS|Unknown|Queda de SCM Hercules durante instalação|DLFL NOCO|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZB|100054943|10/10/2011|priority 1 |Q1|Unknown|Unknown|Client notified in short notice|NOPT NOTE NOCO|Lack of communication and process|FMC Other Defect |Functional|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Planning error
ZF|P6000068924|31/01/2012|priority 3 |Q3|TOTAL|Unknown|Current reading outside accept crit.|NOTE ATCO NOCO NOPT|Corrected by SW-calibration|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #9 Wiring|ATCO NOPT NOCO NOTE|BPTH SKOFLO SCM SN #9 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000105542|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000088626|14/05/2018|priority 3 |Q3|Unknown|Unknown|SCM  HCM HFT on BP SD 2 PMA's WF1 & 2|NOTE NOCO ATCO|Update of procedure.|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Causes for Improvement|Documentation
ZF|P6000088751|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOPT NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7102969|Unknown|priority 3 |Q1|Unknown|Unknown|LP Control Valve line 11  leaking subsea|NOTI NOCO ATCO NOPT|Back wall of CV not secured|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Leakage
Q3|100017305|01/11/2002|priority 3 |Q3|Unknown|Unknown|FlowMeter inputs(Counter Interfaces)def.|NOCO NOTI NOPT ATCO|Unknown|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Function
Q3|7102643|21/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|Feil på SCM|NOCO NOPT ATCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|100018531|11/09/2002|priority 3 |Q1|SHELL|Unknown|SCM 2 Bijup.& Salema PTCD card malfunct.|NOCO NOTI NOPT ATCO|Unknown|103-Electrical|SEM Powersupply|Defect locations - offshore/field|Sahara (Biju)|Initial/Direct product problem|Function
ZF|P6000042969|02/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Change hydraulic coupler|ATCO NOTE NOPT NOCO|Sharp edge on Male coupler   test equip.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZF|100035013|15/10/2010|priority 3 |Q3|SHELL|Unknown|O.L. D3 SEM A fiber fault|NOTE NOCO ATCO|Transfered to QN 200084493|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000008275|24/01/2012|priority 1 |Q3|Unknown|Unknown|Issue on PT 16.|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000084242|15/08/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Rebuild to Copi South Belut from Bawal|ATCO NOTE NOCO|Requested rebuilt for new project|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000064911|30/11/2011|priority 1 |Q3|TOTAL|NORTH SEA|couplers loose on two modules|ATCO NOCO NOTE NOPT|Couplers were not torqued.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000016420|13/09/2011|priority 1 |Q3|Unknown|Unknown|Revestimento do Pino Guia|NOTE NOPT ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
Q3|7102643|30/12/1999|priority 2 |Q3|Unknown|Unknown|Possible miscoupled wires for LD & LVDT|NOCO ATCO NOTI NOPT|See long text|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Problem causes  defect causes|Production personnel
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|HFT ACCEPTANCE CRITERIA NOT MET|NOPT NOTE NOCO ATCO|HFT DOC. & TEST UNIT DISCREPANCY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|P6000050867|28/09/2011|priority 3 |Q3|Unknown|Unknown|Upgrade with new software|NOTE ATCO NOCO NOPT|Product update|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZD|100049000|20/07/2007|priority 1 |Q2|BP|Unknown|Incorrect Nameplate SEM Markings|NOPT ATCO NOCO NOTE|Incorrect SEM address on SCM nameplate|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|Unknown|Trafo problems on Agbami S/N 29|NOTE NOPT NOCO ATCO|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100048038|21/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|Change of restrictors|ATCO NOTE NOPT NOCO|FMC Houston - restrictor size change|Change/Deviation Request |Part substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P7000008275|27/06/2012|priority 1 |Q3|Unknown|Unknown|Vazamento de silicone pelo strainer|ATCO NOPT NOTE NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Compensator|FMC Assy |Operator Error
ZD|P6000084242|08/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PARTNUMBER|NOCO NOTE NOPT ATCO|INCORRECT PARTNUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P7000001621|24/11/2010|priority 1 |Q3|Unknown|Unknown|Compensador fora da classe de limpeza.|NOTE NOCO NOPT ATCO|Classe limpeza acima do especificado|Test Related |OBS-Cleanliness|SS - Controls - Hydraulic Products|Compensator|Vendor related |Specification not followed
ZF|P6000108984|14/11/2013|priority 3 |Q3|Unknown|Unknown|Wrong in configuaration file BAYU UNDAN|ATCO NOPT NOTE NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P6000145982|20/04/2018|priority 2 |Q3|Unknown|Unknown|SEM  DHI issue during EFAT test|NOTE NOPT ATCO NOCO|Board loose data on power loss.|TEST |Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Software |Other- Specify in comments
ZF|100056443|03/04/2017|priority 3 |Q3|EDISON/EDF|NORTH SEA|Uncontrolled DCV operations|NOTE NOCO|Followed up on ZE Qn 200533520|Damage |Damage from corrosion|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Other causes/damage |Cause not found
ZF|100036936|20/03/2007|priority 2 |Q3|STATOIL|NORTH SEA|Missing filters seawater compensator SCM|NOPT NOTE NOCO ATCO|No external inspection before transport|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Logist.-Handling/Packing/Shipping error
ZF|P6000039844|06/05/2009|priority 3 |Q3|SHELL|Unknown|Communication problems in hyperbaric|NOTE NOCO NOPT|Error to be confirmed in QN200124450|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|Vendor related |Unknown
Q3|7100320|Unknown|priority 3 |Q3|Unknown|Unknown|Upgrading of Hercules SCM SN 08|ATCO NOPT NOTI NOCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|P6000064909|14/04/2011|priority 3 |Q3|Unknown|Unknown|Spec error: Wrong temp sensor position|ATCO NOCO NOPT NOTE|Human failure  misunderstanding|Documentation |Procedure / Process Error|SS - Controls - Electronic Boards|Power units|FMC Engineering related |Specification error
Q2|7105130|28/11/2000|priority Unknown|Q2|Unknown|Unknown|SCM M 06|NOTI NOCO ATCO NOPT|Unknown|103-Electrical|SEM Powersupply|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Function
ZF|P6000107981|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7105128|12/12/2001|priority 3 |Q3|TOTAL|Unknown|SCM HP leak SCSSV Girassol S/N 4|NOPT ATCO NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Girassol FPSO|Initial/Direct product problem|Leakage
ZF|P7000008275|05/12/2012|priority 2 |Q3|Unknown|Unknown|Top plate TBU SN 05 danificada|NOTE ATCO NOCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Planning error
ZF|100048038|31/03/2007|priority 1 |Q3|AGBAMI|Unknown|Check valve - High leak|ATCO NOCO NOTE NOPT|scratch on the surfice inside the valve|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|7104670|14/04/2000|priority 1 |Q3|Unknown|Unknown|Short circuit on Sand Detector|NOPT NOTI ATCO NOCO|SIO card|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-EFAT|Initial/Direct product problem|Function
ZF|P6000073613|13/05/2013|priority 3 |Q3|Unknown|Unknown|we have get wrong pn and w15L is marked|NOTE NOPT NOCO ATCO|Fault in BOM  update part nr|Design |Specification Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Specification error
ZF|100033987|07/10/2004|priority 3 |Q3|STATOIL|NORTH SEA|Damage to COV and wiring|NOPT ATCO NOTE NOCO|Interference outer can / COV & wiring|Assembly / Test related |Handling Damage|Subsea Control Module (SCM) Electrical|Wiring|FMC Engineering related|Design Specification/Drawing error
ZF|P6000042968|20/01/2011|priority 2 |Q3|Unknown|Unknown|AI Ch. 10 don`t work during testing|NOPT NOCO NOTE|Follow-up covered by QN200192345|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Harness|Vendor related |Clarification
ZF|100030711|14/03/2014|priority 2 |Q3|STATOIL|Unknown|CPU card revision Level|NOTE NOCO|Current SW will work for new (Rev J) HW|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|20/04/2015|priority 1 |Q3|Unknown|Unknown|Extension Rod oxidada|NOTE NOPT NOCO ATCO|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Final Inspection Error
ZF|P6000121958|13/03/2015|priority 2 |Q3|Unknown|Unknown|Pt 62 has wrong threads|NOTE NOCO NOPT ATCO|Drawing error|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |DWG Error
Q3|7105129|03/10/2003|priority Unknown|Q3|TOTAL|Unknown|SCM 06 SCM 06 Wo/DHI Damaged Ext Rod|NOPT NOCO ATCO NOTE|Not  yet found  to be stated.|101-Mechanical|Locking Mechanism|Ext. Loc. - Luanda (Angola)|Work Shop|Unknown|Unknown
ZF|P6000028371|11/04/2008|priority 3 |Q3|SHELL|GOM|Batch numbers missing in iBASE list|NOTE NOCO NOPT|Change: batch cert. to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #20 Wiring|NOTE NOCO ATCO NOPT|BPTH SKOFLO SCM SN #20 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100049000|12/10/2010|priority 3 |Q3|BP|GOM|Dropped below 2% pressure drop|NOCO NOTE NOPT|Not noticed during pressure test|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
Q3|3794920|16/01/2003|priority 3 |Q3|STATOIL|NORTH SEA|DHI-problemer|NOTE ATCO NOCO NOPT|Power Supply 24V|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|P7000024900|24/07/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|NOCO NOTE ATCO NOPT|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7102643|Unknown|priority 1 |Q1|Unknown|Unknown|Connector EC2 is mounted 90 deg. wrong|NOCO NOPT NOTI ATCO|Assembly error|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|7103233|06/01/2006|priority 2 |Q3|Unknown|Unknown|Leaking SCM Production.|NOCO NOPT ATCO NOTE|Leaked onbord  no leak during test at Ko|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q2|100016711|15/01/2003|priority 3 |Q2|Unknown|Unknown|SEM A 12 VDC converter failed|NOPT NOCO NOTE ATCO|Unknown|103-Electrical|SEM El.Rack|Ext. loc. - KOS Houston|Work Shop|Initial/Direct product problem|Function
ZF|P6000043122|07/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Flow meter not working|ATCO NOCO NOPT NOTE|Contamination in control system|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|FMC Test |Damaged during testing
ZF|P6000074156|03/04/2012|priority 3 |Q3|Unknown|Unknown|Dhi 204|NOTE NOCO ATCO NOPT|All eight DHI204 with erratic FW  traced|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Design Error
ZF|100054943|04/10/2018|priority 3 |Q3|Unknown|Unknown|Vincent OH09 OH & SEM615 Incomplete MRB|NOTE ATCO NOCO|Unknown|Documentation Requirement |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Documentation Requirement |Input requirements missing
ZF|P7000000897|06/10/2016|priority 1 |Q3|SHELL|Unknown|MMR - Change Over HP with reversed link|NOPT ATCO NOCO NOTE|Unknown|TEST |Function|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Operator Error
ZF|P6000080343|30/09/2013|priority 4 |Q3|TULLOW|WEST AFRICA|MMRSCM Jubilee SN2  Leakage|ATCO NOTE NOCO|Leakage likely caused by particles|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO ATCO NOPT NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|100016901|28/04/2010|priority 3 |Q1|SHELL|GOM|EC connector sealing faces corroded|ATCO NOTE NOCO|EC connector sealing faces corroded|Damage |Damage from corrosion|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |No Non-Compliance
ZF|7102969|07/03/2006|priority 3 |Q3|EXXONMOBIL|Unknown|INTERFACE ERROR|ATCO NOPT NOTE NOCO|BLADDER NIPPLE THREAD LENGTH EXCESSIVE|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|P6000063531|09/04/2018|priority 3 |Q3|Unknown|Unknown|Cancelled|DLFL NOCO|Unknown|Software |Program configuration|Object Types to Eng Matl CLASS|scm_mkIII|Software |Other- Specify in comments
Q3|7104033|19/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|Silicon leak on compensation system SCM|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|100049000|18/12/2006|priority 3 |Q3|Unknown|Unknown|BP instruction for AI150 card upgrade|NOTE NOPT NOCO ATCO|Customer instruction|Change/Deviation Request |Part substitution request|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes |No Non-Compliance
ZF|P7000000229|10/02/2015|priority 1 |Q3|CHEVRON|Unknown|MMR - Process error|NOCO ATCO NOTE|Missed Operation|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|100030542|23/07/2014|priority 3 |Q3|Unknown|Unknown|Too high temperature causing failures.|NOTE NOPT NOCO|Temperature too high in workshop|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P7000001843|04/11/2014|priority 1 |Q3|PETROBRAS|Unknown|MMR - Hyperbaric Setup|NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100056261|06/03/2008|priority 2 |Q3|MURPHY|WEST AFRICA|Replacement of DCV's|NOPT NOCO ATCO NOTE|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000031350|16/04/2009|priority 1 |Q3|Unknown|Unknown|He leak test not performed iaw process|NOPT NOCO ATCO NOTE|communication problems in workshop.|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P6000062454|05/12/2011|priority 3 |Q3|DAEWOO|Unknown|Verify test equipment  HPU/SCMTS|ATCO NOCO NOTE|Damage during incorrect testing|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|P6000103208|17/10/2016|priority 4 |Q3|Unknown|Unknown|(E) - SCM Communication Issues|NOCO NOPT NOTE ATCO|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Electrical |Design Error
ZF|100048038|20/03/2012|priority 3 |Q3|CHEVRON|WEST AFRICA|PIV  PT and SEM Temp Anomaly Readings|NOCO NOTE NOPT ATCO|PIV  PT and SEM Temp Anomaly Readings|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |No Non-Compliance
ZB|100020278|12/05/2010|priority 2 |Q1|EXXONMOBIL|Unknown|SCM comm's fault found during CDT|NOCO NOTE ATCO|SCM comm's fault found during CDT|Test Related |OBS-Component Error|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Test |Damaged during testing
ZF|P7000001621|27/07/2015|priority 2 |Q3|Unknown|Unknown|MMR - Falha de leitura de PTs internos|ATCO NOTE NOCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM el/opt components|Other el/opt components|FMC Materials/Stores related |Improper Handling
ZF|P6000091085|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000064909|13/04/2012|priority 4 |Q3|TOTAL|NORTH SEA|We did not get communicaton with the SCM|NOCO NOPT NOTE|SCM was sent back to the workshop|Documentation |Procedure / Process Error|SS - Controls -Computer system software|Network config|Intercompany|FMC Kongsberg
ZF|P6000101955|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000104111|08/06/2017|priority 2 |Q1|Unknown|Unknown|Egina WC 0020 SCM PT failure MIV1|NOTI OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7102643|23/02/2004|priority 3 |Q3|Unknown|Unknown|FAIL WITH VALVE HP|ATCO NOTE NOPT NOCO|SCM return overpressurised|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Assembly/Test related|Operator error
ZF|100034440|05/04/2005|priority 3 |Q3|Unknown|Unknown|Re-test of  Accumulator on MKIV|ATCO NOTE NOPT NOCO|Acc. not available when perf. press test|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Handling
ZB|7104670|07/12/2010|priority 4 |Q1|STATOIL|NORTH SEA|F&D Recall the backup SCM|NOCO NOPT NOTE|Unknown|Change/Deviation Request |Raw Material substitution request|Customer Compliant|Noncompliance to Customer Requirement|FMC Engineering related |Specification error
ZD|P6000028371|15/09/2015|priority 3 |Q2|Unknown|Unknown|Damage EC|ATCO NOCO NOTE|damage ec|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|3794920|19/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|Batch numbers missing|NOPT NOCO NOTE|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P1000018406|03/02/2009|priority 1 |Q3|BP|GOM|DFCM will not build pressure|NOTE NOPT NOCO ATCO|DFCM will not build pressure|Test Related |OBS-Function|SS - Controls - Sensors|SCM Flowmeter|Vendor related |Equipment Malfunction
ZE|100046112|04/05/2013|priority 2 |Q3|Unknown|Unknown|Angel - SCM Issue|NOTE ATCO NOCO NOPT|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P7000001621|14/10/2013|priority 1 |Q3|PETROBRAS|Unknown|MMR - DHI 1 SEM A NÃO COMUNICA|NOCO NOPT ATCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Other causes/damage |Cause not found
ZF|P6000063531|22/10/2014|priority 3 |Q3|STATOIL|NORTH SEA|Vigdis VEPIII rebuild flowmeter|NOTE NOCO| F.M. not reading minimum flow|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
Q3|7101172|02/11/1999|priority 3 |Q3|Unknown|Unknown|CIDV supply pressure drops  well H-1H|ATCO NOCO NOPT NOTI|Unknown|Product defects for dept. 1650|1651 Flow Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|7105129|18/08/2003|priority 3 |Q3|GIRASSOL OPTION|Unknown|INCORRECT ASSEMBLY|NOTE NOPT NOCO|Error in configuration engineering|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Engineering related|Design Specification/Drawing error
ZF|100048038|17/12/2006|priority 1 |Q3|CHEVRON|Unknown|POD LEAKING AT RELIEF VALVES|NOCO NOPT NOTE ATCO|Vendor-Component Error|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|100013155|23/01/2001|priority 3 |Q3|OVERALL PROJECT ROLL-UP|Unknown|Control valve test results out of limits|NOCO NOPT NOTI ATCO|No fault found. Procedure to be changed|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Tank test|Root cause Engineering|Test Procedure error
ZF|100017997|13/09/2006|priority 3 |Q3|BP|Unknown|Leakage   Water in silicone.|NOTE NOPT ATCO NOCO|interface connection leak|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100038200|05/08/2011|priority 2 |Q3|SHELL|Unknown|Perosity in the Welds of EC Seal Surface|NOCO NOTE NOPT ATCO|Perosity in the Welds of EC Seal Surface|Damage |Damage from corrosion|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Damaged during assembly
ZF|P6000122574|19/07/2018|priority 2 |Q3|Unknown|Unknown|Missing information in Documentation|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100050383|11/05/2016|priority 3 |Q3|Unknown|Unknown|Company decide to not upgrade el.boards|NOCO NOTE ATCO|Unknown|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Customer Error
ZF|P7000039672|27/05/2013|priority 1 |Q3|Unknown|Unknown|Wrong Pressure transducer delivered.|NOPT ATCO NOTE NOCO|SCANSENSE - PO 47456838|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Wrong Part Delivered
ZF|P6000104111|16/06/2015|priority 3 |Q3|Unknown|Unknown|Lost communication to CPU in burn in|NOCO NOPT NOTE|Failure in test equipment|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|08/03/2017|priority 2 |Q3|Unknown|Unknown|ECN 6209019 - P7000039672 - CDM|ATCO NOCO DLFL|CORRECTION OF PART NAME ON DBI. DURING L|Design |DBI Error|Object Types to Eng Matl CLASS|clamps_common|FMC Other causes/damage |QN Cancelled
ZF|P6000088604|14/11/2012|priority 3 |Q3|Unknown|Unknown|dokuneent is not correct|NOPT NOTE NOCO ATCO|Incorrect linking in DBI/DWG|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P6000105542|30/07/2013|priority 1 |Q3|Unknown|Unknown|Removal of SCM interchangeability|NOCO ATCO NOTE|Removal of SCM interchangeability|Documentation |Missing Certificates / Records|MLA - Raw Material|Forgings|QA/QS/QI Related|Goods Receiving Inspection error
ZF|100006609|12/04/2010|priority 2 |Q3|Unknown|Unknown|Conexão presa a rosca|NOTE ATCO NOPT NOCO|Degradação submarina|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Damaged during assembly
ZF|100037965|30/11/2016|priority 4 |Q3|Unknown|Unknown|No communication with Sem A or Sem B|ATCO NOTE NOCO NOPT|Transformer failure caused short circuit|TEST |Component Error|Subsea Control Module (SCM) Electrical|Processor PCBs|FMC Test |Damaged during testing
ZF|P7000039672|08/01/2016|priority 1 |Q3|Unknown|Unknown|DCV low pressure inoperante|NOPT ATCO NOTE NOCO|Unknown|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Damaged during assembly
ZF|P6000107981|10/07/2014|priority 4 |Q3|Unknown|Unknown|Check valve on outercan is skewed.|NOCO NOPT NOTE|OC check valve interface not askew|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000069820|09/05/2011|priority 3 |Q3|Unknown|Unknown|Wiring fault on CVHP22 and CVHP23|NOTE NOPT NOCO|Wrong wiring  human error.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100036936|20/09/2007|priority 2 |Q3|STATOIL|NORTH SEA|Problem with connecting MFM|NOTE ATCO NOCO NOPT|No error in SCM  Simulator is corrected|Assembly/Test Related |Interface of components issue|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes |No Non-Compliance
Q3|7102643|24/02/2000|priority 4 |Q3|Unknown|Unknown|All SCMs to have hyd. flow restrictors|NOPT NOCO ATCO NOTI|Instructions from system engineering|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000108984|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOPT ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|13/02/2016|priority 1 |Q3|Unknown|Unknown|PT does not fit on Manifold Block|NOPT NOCO NOTE ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Final Inspection Error
ZF|P6000109194|27/02/2014|priority 3 |Q3|Unknown|Unknown|LP Return Flowmeter not working properly|NOTE NOPT ATCO NOCO|Unstable readings  follow-up QN200369178|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|P6000121958|25/02/2015|priority 3 |Q3|Unknown|Unknown|Wrong hole size in manifold block|NOTE ATCO NOPT NOCO|Machined M8 threads  specified M10|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|P6000069056|13/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000067533|08/01/2013|priority 1 |Q3|Unknown|Unknown|SCM Modules stored outside with no PSM|NOTE NOCO ATCO|Improper Storage|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
ZB|P6000063531|11/09/2018|priority 3 |Q1|Unknown|Unknown|Bad jumper connector or SCM-socket|NOPR OSTS NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOTE NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000104112|19/08/2015|priority 3 |Q3|Unknown|Unknown|diam out of tollerance|NOTE NOPT NOCO ATCO|Diam out of tolerance|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Damaged during assembly
ZF|P6000077632|04/02/2013|priority 1 |Q3|Unknown|Unknown|FAT parcially done w/o Proj DLL|NOCO NOTE NOPT ATCO|Wrong DLL loaded at the begining.|Test Related |OBS-Missed Operation|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Test |Operator Error
ZD|100038200|18/06/2011|priority 3 |Q2|SHELL|Unknown|Contamination/Perosity in Welds|ATCO NOPT NOCO NOTE|Contamination/Perosity in Welds|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Outer Can|Intercompany|FMC Kongsberg
ZF|P7000000897|23/02/2011|priority 1 |Q3|Unknown|Unknown|OTFF board out of work|NOPT ATCO NOCO NOTE|No 24 voltage on output|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Power units|Vendor related |Equipment Malfunction
Q3|7103233|14/03/2001|priority 4 |Q3|Unknown|Unknown|Suspect SCM HP rtn was over pressured|ATCO NOPT NOTI NOCO|FMC test procedure error has damaged SCM|102-Hydraulic|Hydraulic Control Valves|Ext. Loc. - St.Johns (Canada)|Work Shop|Root cause Engineering|Test Procedure error
ZF|100017278|11/03/2008|priority 4 |Q3|STATOIL|NORTH SEA|Jumpers did not reach parking recept|NOPT NOCO NOTE|Unknown reason for failure|Design |Specification Error|SS - Controls - Electric/Optical Jumpers|Electric Flying Lead|FMC Other causes/damage |No Non-Compliance
Q3|7104670|24/09/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM 06 Heidrun Possible SIO-failure|ATCO NOPT NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100051269|10/05/2007|priority 2 |Q3|Unknown|Unknown|Incorrect drawings during SCM Final Insp|NOCO NOPT NOTE ATCO|incorrect marking on drawings|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100029564|05/09/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Absence of Shackles|OSTS NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOCO NOTE NOPT|ECN 7058839 - P7000017839|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|17/10/2013|priority 1 |Q3|Unknown|Unknown|Arranhão na Base Plate|NOTE ATCO NOPT NOCO||1756 - UVDAL MASKINFABRIKK A/S|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Damage during transport
ZF|100037965|22/08/2005|priority 3 |Q3|BP|Unknown|HYDRAULIC COUPLER HC 1 IS LEAK|NOTE ATCO NOPT NOCO|Unknown|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - Hydraulic Products|Coupler|Vendor related |Fabrication error
ZF|P6000029772|27/08/2009|priority 2 |Q3|Unknown|Unknown|Hose clip on Opt. con. must be changed|NOPT NOTE NOCO|See ZF-QN 200137582|Design |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Design Error
Q3|7102969|Unknown|priority 2 |Q3|Unknown|Unknown|Feil i Hyperbaric-test.TPR-0010405|NOPT ATCO NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Documentation
Q3|7104033|04/07/2002|priority 3 |Q3|STATOIL|NORTH SEA|Flowmeter ?|NOPT NOCO NOTI ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q2|7104075|12/07/2000|priority 2 |Q2|Unknown|Unknown|Elektronikk B feilet etter SCM er fylt.|NOPT ATCO NOTE NOCO|Elkort feilet|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
ZD|100055600|21/09/2011|priority 3 |Q2|REMINGTON OIL AND GASHOUSTON STOCKING SCM MK II (15K)|Unknown|Outer Can sandblasting|NOCO NOPT ATCO NOTE|Outer Can Sandblasting|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|100046112|19/05/2010|priority 3 |Q3|Unknown|Unknown|No information in test procedures.|NOCO NOTE ATCO|Procedure error|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZE|P6000090632|25/09/2013|priority 3 |Q3|Unknown|Unknown|Variance in flow restrictors|ATCO NOCO NOTE|Improve naming and tolerances|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Variance|Enhance Process
ZF|100037966|22/03/2008|priority 1 |Q3|BP|Unknown|FPSO NCR 26 - SCM Failure|NOTE NOPT NOCO ATCO|Unknown|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|P6000039844|22/08/2018|priority Unknown|Q3|Unknown|Unknown|Missing test equipment / CR request|NOPT NOCO NOTE|Unknown|Electrical |Other- Specify in comments|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Incorrect set up/testing
ZB|100017278|14/09/2008|priority 3 |Q1|STATOIL|NORTH SEA|Leakage in solenoide valve in SCM|NOCO NOTE NOPT ATCO|Unknown|Change/Deviation Request |Unknown|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Other causes/damage |Unknown
ZF|P6000065886|10/02/2011|priority 2 |Q3|Unknown|Unknown|DHI107 not working Sem B  SCM wiring err|ATCO NOTE NOPT NOCO|Human failure  checklist not followed|Design |Specification Error|SS - Controls - Electric Products|Electrical Harness|FMC Engineering related |Specification error
ZB|100030542|15/05/2009|priority 3 |Q1|BAOBAB|Unknown|Delay in sending of SCM RAM chip lettte.|ATCO NOTE NOCO NOPT|Slow process of product defect notice.|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |Unknown
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|Unknown|Possible chips inside the HP-Config Plug|NOTE NOCO|Cleanliness requirement not followed.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZF|100035013|15/10/2010|priority 2 |Q3|SHELL|Unknown|Material not delivered to plant|NOTE NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZE|P6000145982|21/11/2018|priority 3 |Q3|Unknown|Unknown|SEM  Damaged MRM/LNCT Card|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104075|11/05/2000|priority Unknown|Q3|Unknown|Unknown|LP supply line subjected to 276 bar|NOCO ATCO NOPT NOTI|Check valve installed wrong way round|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Tank test|Initial/Direct product problem|Function
ZF|100035118|18/02/2005|priority 3 |Q3|PETRONAS|Unknown|SCM FAILED DURING X-TREE FAT|NOPT ATCO NOTE NOCO|Power unit failure  24V output.|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
Q3|7101172|21/09/2000|priority 2 |Q3|Unknown|Unknown|SCM hydraulic leak  ca 18 l/d  well H-1H|ATCO NOTI NOPT NOCO|Leaking control valve|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZD|P6000068902|05/10/2011|priority 3 |Q2|Unknown|Unknown|Protector Cover for PT and valves|NOPT ATCO NOTE NOCO|PT covers full of plastic burrs & chips|Machining Related |OBS-Burr/Chips|SS - Controls - Electric Products|Electrical Protection Cap|Vendor related |Specification not followed
Q3|7102643|11/09/2001|priority Unknown|Q3|STATOIL|NORTH SEA|EPROM SW-failure alternativly prog.SEM B|NOCO NOPT ATCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P6000065528|14/04/2011|priority 3 |Q3|Unknown|Unknown|Ethernet test outside criteria|NOTE NOCO ATCO NOPT|No SCM deviation  error in TestSt wiring|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|7103905|30/03/2007|priority 2 |Q3|FPS-PRODUCT & SYSTEM SALE - ABERDEEN & D|Unknown|SCM LP Acc. charging fitting discrepency|NOTE ATCO NOPT NOCO|Valve changed on Accumulator|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Accepted -&|Accepted
ZF|P7000024191|11/10/2012|priority 1 |Q3|Unknown|Unknown|Furos da Protection Ring fora de centro|NOCO NOTE NOPT ATCO|Peça ovalizada|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P6000063531|27/12/2010|priority 1 |Q3|Unknown|Unknown|CPU600 improving startup on long umbilic|NOCO NOTE ATCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000105542|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|SO due to DC/DC Issue on AI150 card|NOTE ATCO NOPT NOCO|Component Failure/Poor Workmanship|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZF|7103233|24/08/2011|priority 2 |Q3|SUNCOR|Unknown|Missing bolts and leaking SCM|NOCO NOTE NOPT ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Assy |Missing Parts
ZF|P6000098616|15/10/2013|priority 1 |Q3|SHELL|Unknown|MMRSCM Shell SN 422 Outercan Coating|NOCO ATCO NOPT NOTE|Faded spot painting after hyperbaric|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZB|100036936|18/02/2009|priority 4 |Q1|STATOIL|NORTH SEA|F&D Problems with communication Sem A|NOTE NOCO ATCO NOPT|SCM did not work as intended|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage during transport
ZF|P6000037365|04/07/2008|priority 3 |Q3|Unknown|Unknown|Too high leakage on control valve|NOCO NOTE ATCO NOPT|High leakage during testing|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Vendor related |Specification not followed
ZF|P6000088751|03/10/2012|priority 3 |Q3|Unknown|Unknown|Problems with eth. connection on EC3|NOTE ATCO NOPT NOCO|Follow-up covered by QN 200290318|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZF|100018531|04/08/2011|priority 1 |Q3|Unknown|Unknown|Sensor 4-20 mA readings issue|NOCO NOPT NOTE ATCO|Reading out of acceptance criteria|Test Related |OBS-Function|SS - Controls -Instrumentation|Other SCM instruments|FMC Other causes/damage |Damage from Wear and Tear
ZF|7105597|21/10/2010|priority 2 |Q3|PETRO SA; MOSSEL BAY|Unknown|Material not delivered to plant|NOTE NOCO|Unknown|Documentation |Procedure / Process Error|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|Projects Related|Documentation error
ZB|P6000029772|11/10/2011|priority 1 |Q1|ENGIE|NORTH SEA|Gjøa Claim 046 SRM SN 4 & 5|ATCO NOTE NOCO NOPT|Batch of leaking fibrepenetrators|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Assembly error
ZF|P7000000897|04/10/2011|priority 1 |Q3|SHELL|Unknown|Danos na área de vedação.|ATCO NOCO NOPT NOTE|Uvdal|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Packaging/Handling
ZF|P7000008275|25/06/2013|priority 1 |Q3|Unknown|Unknown|Center tubing com erro TBU #01|NOCO ATCO NOTE NOPT|SCM MMR|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Machine Shop Personnel |Operator error
ZF|P7000039672|23/05/2013|priority 1 |Q3|Unknown|Unknown|Solda da adapter plate LP danificada|NOCO NOPT NOTE ATCO|BOSCH REXROTH - 123643 - PO 47586275-6|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Equipment Malfunction
ZF|100025661|14/07/2006|priority 3 |Q3|SHELL|GOM|DAMAGE TO EC CONNECTORS|NOPT NOTE NOCO ATCO|DAMAGE TO EC CONNECTORS|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
Q3|7100320|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Hercules SCM 15|ATCO NOCO NOTI NOPT|Wrong material|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|100037966|21/03/2007|priority 3 |Q3|BP|Unknown|SCM Pressure sensor show incorrect data|NOCO NOPT NOTE ATCO|awaiting results of failure investigatio|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
Q3|7103233|16/02/2001|priority 4 |Q3|OVERALL PROJECT ROLL-UP|Unknown|SCM PTs to be upgraded/tested|ATCO NOPT NOTI NOCO|Supplier design error|103-Electrical|Pressure Transducer|Ext. loc. - KOS Houston|Work Shop|Root cause Vendor|Design error
ZF|P6000104111|25/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100049000|25/09/2007|priority 2 |Q1|BP|GOM|SEM A failed to restart.|ATCO NOTE NOCO NOPT|SCM need to be sent back to Norway.|Assembly/Test Related |Function|Control System Topside Electrical Eq.|Other Control Syst. Topside El. Equip.|Vendor audit related|Unknown
ZF|7105128|06/03/2004|priority 2 |Q3|TOTAL|Unknown|SCM 15P from GIR 102 LP A Leak|NOCO ATCO NOPT NOTE|Overpressurisation of LP A during WO.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Other causes|Miscellaneous
ZB|100066325|09/04/2018|priority 3 |Q1|Unknown|Unknown|Cancelled|NOTI NOCO DLFL|Unknown|TEST |Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
Q3|100018600|06/02/2003|priority Unknown|Q3|Unknown|Unknown|Fluctation of external sensor readings|NOTI NOPT ATCO NOCO|Test cable caused crosstalk|Unknown|Unknown|Unknown|Unknown|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|100018820|13/06/2003|priority 3 |Q3|EXXONMOBIL|NORTH SEA|LEAKAGE  IN HP LINE|ATCO NOCO NOTE NOPT|Brocken bolt in SCM Manifold Block|Service/maintenance related|Unknown|Standard Components Norway|Fixing Device|Vendor related|Material error
ZF|P7000001621|07/05/2012|priority 1 |Q3|Unknown|Unknown|Parafusos menores que os especificados|ATCO NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Purchasing Error
Q3|7105597|Unknown|priority 3 |Q3|Unknown|Unknown|Center lock damage.|ATCO NOPT NOCO NOTI|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-EFAT|Initial/Direct product problem|Material
ZF|100030665|20/03/2013|priority 1 |Q3|SHELL|Unknown|MMRSCM Pierce 16 SEM Bracket|NOPT NOCO ATCO NOTE|Torque applied by customer is uncertain|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Cause not found
ZF|100037427|06/05/2013|priority 1 |Q3|Unknown|Unknown|DHI 113 functionalty Rosa Capital Spare|NOPT NOTE ATCO NOCO|IgnoreStatusFlag-Doc.update QN200323348|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000105542|12/12/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100020562|31/01/2007|priority 2 |Q1|BP|GOM|PT reading for SCSSV B below acceptable|NOCO NOPT NOTE|PT reading for SCSSV B below acceptable|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P7000039672|30/03/2016|priority 1 |Q3|Unknown|Unknown|Vazamento no Manifold Block|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZD|100016901|20/05/2010|priority 2 |Q2|SHELL|GOM|Surface rusted and holes filled|ATCO NOCO NOPT NOTE|Surface rusted and holes filled|Machining Related |OBS-Burr/Chips|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZD|P6000114972|27/05/2014|priority 3 |Q2|ANADARKO|GOM|Marking|ATCO NOTE NOPT NOCO|See Attached email.|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P7000024191|04/03/2013|priority 1 |Q3|Unknown|Unknown|Possível obstrução da linha de retorno|NOCO NOPT ATCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZF|P6000079433|09/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|DHI simulator not working properly|NOTE ATCO NOCO NOPT|Old SMART-TOOL config file used|FMC Other Defect |Functional|SS - Controls - Test and Transportation|Sensor Simulator (SESI)|FMC Test |Incorrect set up/testing
ZF|P7000008275|10/01/2013|priority 1 |Q3|Unknown|Unknown|ECN NUMERO 7047483  _ PN P700013324|NOCO NOTE NOPT ATCO|ECN|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|7103234|04/01/2012|priority 2 |Q3|SUNCOR CPI|Unknown|Material not delivered to plant|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000043122|25/08/2009|priority 3 |Q3|TOTAL|WEST AFRICA|Documentation must be updated|NOCO NOPT NOTE ATCO|BOM is correct already|Design |DBI Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000024191|01/06/2012|priority 1 |Q3|Unknown|Unknown|Testado em desacordo com o Procedimento|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
Q3|7104670|07/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM failed in operating choke to closed|ATCO NOPT NOCO NOTI|Control Valve Leaking?|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #10 Wiring|NOPT NOTE ATCO NOCO|BPTH SKOFLO SCM SN #10 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 25|NOPT NOCO ATCO NOTE|Investigate Coupler Rotation-BPAT SCM 25|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZB|3812476|29/07/2010|priority 3 |Q1|STATOIL|NORTH SEA|F&D23 Wrong orient. of SCM in skid|NOCO ATCO NOPT NOTE|SCM not correctly install on the transp|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000000897|01/09/2017|priority 3 |Q3|SHELL|Unknown|MMR - Broken Coupler Return line HC 61|NOCO NOTE NOPT ATCO|Coupler Broke due to Assembly Failure|Assembly |Over Torqued|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Assembly |Over torqued
ZF|100026328|26/04/2016|priority 1 |Q3|Unknown|Unknown|MMR - Leakage through Strainer|NOCO NOTE NOPT ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Compensator|Intercompany|FMC Kongsberg
ZF|P6000116166|19/11/2014|priority 3 |Q3|Unknown|Unknown|Wiring fault CAN-bus|NOPT ATCO NOTE NOCO|Wiring error by technician|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZE|P6000091085|13/05/2016|priority 4 |Q3|Unknown|Unknown|Child CAR - OWIRS Deadman sequence|NOCO DLFL OSTS NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000093498|05/09/2014|priority 2 |Q3|Unknown|Unknown|Cell voltage out of balance|NOPT ATCO NOTE NOCO|SW error in previous revision|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
Q3|7105128|23/11/1999|priority 1 |Q3|Unknown|Unknown|SCM P 03|NOPT NOTI ATCO NOCO|Locking mech. center rod  O-ring leaking|101-Mechanical|Locking Mechanism|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Leakage
ZF|3812695|30/04/2003|priority 3 |Q3|Unknown|Unknown|CHANGING BOLTS|NOTE NOCO ATCO NOPT|Change of 12.9 EZ with 12.9 uncoated.|Assembly / Test related |Material Faulty|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Engineering related|Design Specification/Drawing error
ZF|100020562|31/10/2005|priority 3 |Q3|BP|GOM|Thunderhorse HFT document errors|NOTE NOCO ATCO NOPT|Thunderhorse HFT document errors|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|100025661|23/04/2003|priority 3 |Q3|SHELL|GOM|HC51 & HC52 marked opposite of dwg.|ATCO NOTE NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000064911|14/08/2015|priority 3 |Q3|Unknown|Unknown|loose couplers on SRM|NOTE ATCO NOCO|Incorrect couplers in BOM|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|100056176|16/01/2008|priority 3 |Q3|STATOIL|NORTH SEA|missing batch numbers|NOCO NOPT NOTE|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZE|100056443|25/01/2016|priority 2 |Q3|Unknown|Unknown|VEGA HFT60041111 3.9.11 DHI card(DHI204)|NOCO NOTE ATCO|Improve procedure|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|100036232|18/05/2016|priority 2 |Q3|Unknown|Unknown|Cust Con - Protector Caps|NOCO NOTE NOPT ATCO|Customer requirement|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|Unknown|SCM Ruptured Bladder (CNR Baobab)|ATCO NOCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Unqualified Vendor used
ZF|P6000069056|15/08/2011|priority 3 |Q3|STATOIL|NORTH SEA|A small crack on the outercan flange.|NOCO ATCO NOPT NOTE|Crack in Outercan flange|Raw Material |OBS-Defects in material|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Material error
ZF|P6000055213|05/07/2010|priority 2 |Q3|STATOIL|NORTH SEA|Change hydraulic coupler|NOPT ATCO NOCO NOTE|Sharp edge on Male coupler   test equip.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZE|P6000105542|25/01/2016|priority 4 |Q3|Unknown|Unknown|Safe Transport declaration - text colour|ATCO NOCO NOTE|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Test |Wear and Tear
ZF|P7000039672|29/05/2013|priority 1 |Q3|Unknown|Unknown|Missing O-Ring from top/bottom WedgeDisk|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOTE NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000102554|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100001156|18/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|SCM 15 GFA M-3H AI-card SEMB|NOPT NOTE NOCO ATCO|No error in AI150 detected|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Compl. & W.Over - XT - R. Tools|Xmas Tree Running Tool for CXT|FMC Other causes |Do Not Use
ZB|7104033|08/05/2007|priority 2 |Q1|STATOIL|NORTH SEA|Bursted silicone bladder on SCM for mob|ATCO NOCO NOTE NOPT|Customer resp. Storage error|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
Q1|100015538|04/05/2001|priority 3 |Q1|Unknown|Unknown|Pressure Transducers & Hydr.Couplers|NOCO ATCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000016420|30/08/2011|priority 1 |Q3|Unknown|Unknown|Manifold Block P55-09|NOTE ATCO NOPT NOCO|Bosch - manifold block|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|P6000093498|31/07/2014|priority 3 |Q3|Unknown|Unknown|Error in wiring list|NOCO ATCO NOPT NOTE|Wiring list error (human mistak)|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000068902|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000042968|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|SCM to be upgraded acc. to DRM60046044/A|NOTE NOPT ATCO NOCO|Designe error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Specification error
ZF|P6000104115|23/05/2014|priority 3 |Q3|Unknown|Unknown|Wrong drilling of center hole of trafo|ATCO NOTE NOCO NOPT|Follow-up against vendor by QN 200384061|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Clarification
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|Shell control module # 3|ATCO NOPT NOCO NOTI|See description|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Repair
ZF|100037130|06/12/2004|priority 1 |Q3|BOURI  FEAD|Unknown|Leakage of hydraulic oil in EFAT area|NOPT ATCO NOTE NOCO|SCM sprayed with Brayco in workshop|Assembly / Test related |Handling Damage|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Assembly/Test related|Miscellaneous
ZF|P6000058949|14/01/2014|priority 4 |Q3|Unknown|Unknown|CF leakage on accumulator on SCM|NOCO NOTE|Seal in bottom of accumulator leaking.|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Assy |Damaged during assembly
Q3|7104075|Unknown|priority 3 |Q3|Unknown|Unknown|Kort som ikke er kjørt i burn-in.|ATCO NOTI NOCO NOPT|Ombyttning unner test|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|100034440|25/04/2006|priority 4 |Q3|Unknown|Unknown|Corroded SCM-missing catodic protection|NOTE NOCO ATCO NOPT|new system replacing present MK4 system|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |QN Cancelled
ZD|100049000|02/07/2008|priority 3 |Q2|Unknown|Unknown|No DBI referencing this material|ATCO NOPT NOCO NOTE|Missing Documentation|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|ATCO NOPT NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100027228|23/01/2012|priority 3 |Q3|Unknown|Unknown|BOM/DWG need update|NOCO NOTE|Unknown|Design |Material Master Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 08 ÅsgA G4-H PT LP Func. malfunction|NOCO NOTI NOPT ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|P6000098616|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|Rette opp underlag DWG-212820 rev. B|NOCO ATCO NOTI NOPT|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
Q1|7104075|27/12/2000|priority Unknown|Q1|SHELL|GOM|Faulty Pressure transmitter|ATCO NOTE NOCO NOPT|Manufacturing defect|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Shell Alliance GOM|Root cause Vendor|Assembly/Fabrication/Test error
Q3|7105597|21/03/2000|priority 3 |Q3|Unknown|Unknown|Lost comms. with SCM during bad weather|NOPT NOTI ATCO NOCO|SCM damaged during workover|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Initial/Direct product problem|Function
Q3|100025735|03/01/2003|priority Unknown|Q3|Unknown|Unknown|On the ETU no data was read from Annulus|NOPT NOCO NOTI ATCO|Unknown|103-Electrical|SEM El.Rack|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P6000068924|03/11/2011|priority 3 |Q3|Unknown|Unknown|Short circuit when operating EC3|NOCO NOTE NOPT|Improper handling of test cables|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Improper handling
ZF|P6000122626|24/08/2015|priority 3 |Q3|Unknown|Unknown|Bad O-ring|ATCO NOCO NOPT NOTE|O-ring possible long storage time|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Shelf Life Expiry
ZE|P6000105542|18/09/2013|priority 2 |Q3|Unknown|Unknown|Pressure procedures need to be update|ATCO NOPT NOCO NOTE|Improvement of procedures|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Accumulator|Causes for Improvement|Documentation
ZB|100052134|28/11/2007|priority 2 |Q1|PETROBRAS|GOM|COVLP Low Pressure Change Over Valve|NOTE NOCO ATCO|Unknown|Damage |Wear & Tear|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes |No Non-Compliance
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOPT NOTI ATCO NOCO|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
Q3|3787102|Unknown|priority Unknown|Q3|Unknown|Unknown|Unknown|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100046112|24/07/2006|priority 2 |Q3|WOODSIDE|Unknown|ASD does not respond on SEM B.|NOPT NOTE NOCO ATCO|Error in SIO150 board|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZF|P6000064909|30/05/2011|priority 3 |Q3|Unknown|Unknown|Missing serial nr profile in SAP ?|NOTE NOCO NOPT|s/n profile to be implem.  => QN20021167|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|7104033|02/10/2006|priority 4 |Q3|STATOIL|NORTH SEA|Leakage on SCM|NOTE ATCO NOCO|Unknown cause|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100020562|25/05/2006|priority 3 |Q3|Unknown|Unknown|sensor will not read with new ETU|NOPT ATCO NOTE NOCO|Operator Mistake|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q1|7101172|22/04/2002|priority 3 |Q1|Unknown|Unknown|SCM 14 H-1H DHPT failure(gauge-prob.)|NOTI NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104020|Unknown|priority 3 |Q3|Unknown|Unknown|Share-pin function activated|NOTI NOCO ATCO NOPT|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production
ZF|100056443|26/11/2009|priority 1 |Q3|STATOIL|NORTH SEA|Internal communication between PSD A & B|ATCO ORAS NOTE NOCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|P6000029772|03/12/2013|priority 2 |Q3|ENGIE|NORTH SEA|Debris in Strainer|NOTE ATCO NOCO|Contamination  similar QN 200286860|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000067533|27/12/2010|priority 2 |Q3|KIRINSKOYE SPS|Unknown|CPU600 improving startup on long umbilic|NOCO ATCO NOTE|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
Q3|7103553|06/09/2000|priority 3 |Q3|Unknown|Unknown|LP hydraulic leak of 600 litres/day|ATCO NOCO NOTI NOPT|Control valve leaking|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Leakage
ZF|100037966|06/02/2008|priority 3 |Q3|BP|Unknown|Batch numbers missing in iBASE list|NOCO NOTE NOPT|Change: batch cert. to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P7000039672|22/03/2016|priority 1 |Q3|Unknown|Unknown|Base Plate Danificada|NOPT NOTE NOCO ATCO|Unknown|Damage |Damage during transport|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Assy |Operator Error
Q3|100009059|14/02/2001|priority Unknown|Q3|EXXONMOBIL|GOM|M&M SCM transport-damage in US|NOTI ATCO NOCO NOPT|SCM damaged during transportation in US|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Other|Logistics-Packing/Shipping Damage
ZF|P6000108025|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100049000|06/02/2009|priority 3 |Q1|BP|GOM|SEM A failed to restart.|NOPT NOTE NOCO|Defective RAM-chip  reduced lifetime|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZB|P7000000897|Unknown|priority 3 |Q1|SHELL|Unknown|BC10 - SCM Locking Mechanism Not Working|OSNO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000100953|25/11/2013|priority 3 |Q3|Unknown|Unknown|Discolored outercan marking|ATCO NOPT NOCO NOTE|Faded paint lines on outercan|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZB|7104075|27/03/2008|priority 2 |Q1|SHELL|GOM|SCM 8 HP-LP Leak  Macaroni A4|NOTE NOPT ATCO NOCO|SCM 8 HP-LP Leak  Macaroni A4|Test Related |OBS-Leakage (Fluid)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|Vendor related |Equipment Malfunction
Q3|3794920|16/03/2000|priority Unknown|Q3|Unknown|Unknown|Downhole monitoring P/T after SCM modifi|NOTI ATCO NOPT NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
ZF|100016901|02/02/2004|priority Unknown|Q3|BP|GOM|PT failure|NOTE NOCO NOPT|Unknown error. It may be a PT error.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Operation/maintenance related |Expected wear and tear
ZF|P7000024900|25/01/2013|priority 1 |Q3|Unknown|Unknown|SCM BC 10 39 - lack of el can orin|NOTE NOPT NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|P7000020444|17/10/2012|priority 1 |Q3|Unknown|Unknown|Pino guia não monta - MARLIM SN 03|NOPT ATCO NOCO NOTE|Sem evidência da causa|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|P7000039672|05/11/2015|priority Unknown|Q3|Unknown|Unknown|Base Connector Damaged|NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|El. Connector|FMC Assy |Damaged during assembly
ZF|P7000001621|02/04/2013|priority 1 |Q3|Unknown|Unknown|Hércules  Lab Test box Max. Voltage|NOTE NOPT NOCO ATCO|SCM MMR|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100056261|10/01/2008|priority 3 |Q3|MURPHY|WEST AFRICA|Batch numbers missing in iBASE list|NOTE NOCO NOPT|change batch sertificat to batch managem|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100033987|26/08/2004|priority 2 |Q3|Unknown|Unknown|Unstable readings from analog DHI gauge|NOPT NOTE NOCO|Simulator instability  long term use.|Vendor related|Unknown|Subsea sensors (not in SCM)|Other Subsea sensors|FMC Operation/maintenance related |Expected wear and tear
ZF|100038200|04/07/2013|priority 3 |Q3|Unknown|Unknown|Anadarko RIT Procedure Update|NOTE NOCO ATCO|RIT procedure needs to be revised|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000008275|22/11/2011|priority 1 |Q3|Unknown|Unknown|Troca de fluido SCM Tambau SN 11|NOPT ATCO NOCO NOTE|Unknown|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000064911|20/04/2015|priority 2 |Q3|TOTAL|NORTH SEA|OC in outercan|NOCO NOTE ATCO|Outer Can not produced within SPC|Test Related |OBS-Function|SS - Controls -SCM el/opt components|Opt. Connector|Vendor related |Specification not followed
ZF|P6000039844|19/10/2010|priority 2 |Q3|SHELL|Unknown|Material not delivered to plant|NOTE NOCO|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
Q3|7104075|28/02/2001|priority Unknown|Q3|SHELL|GOM|CVLP-23 will not close|NOCO NOPT ATCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100035013|12/10/2006|priority 4 |Q3|Unknown|Unknown|Workshop error  Documentation|ATCO NOCO NOPT NOTE|Unknown|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100035400|27/05/2005|priority 3 |Q3|Unknown|Unknown|SCM 55/llog 1 broken EC connector|ATCO NOPT NOTE NOCO|Broken plastic boot on EC7|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100027228|18/09/2003|priority 2 |Q3|Unknown|Unknown|HP return line overpressurised|NOPT NOTE NOCO ATCO|HP return line overpressurised|Service/maintenance related|Off-limit Pressure|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Assembly/Test related|Operator error
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 07  Bytting av trykktrandsusere.|NOTE ATCO NOPT NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|P6000083428|06/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100020278|01/12/2010|priority 2 |Q3|Unknown|Unknown|Pin not fit|NOCO NOTE NOPT|Change pin to smaller one which fits|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|P7000001843|02/02/2017|priority 3 |Q3|PETROBRAS|Unknown|MMR - EC6  EC7 and EC8 Damaged|NOTE NOPT NOCO ATCO|Absence of Guide Bush on SCMTS|Damage |Damage during assembly|SS - Controls -SCM el/opt components|El. Connector|FMC Test |Incorrect set up/testing
ZB|P6000080678|02/12/2014|priority 1 |Q1|Unknown|Unknown|SCM inability to read MLCS PTTT|ATCO NOCO NOTE|SCM inability to read MLCS PTTT|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZF|P6000069056|20/02/2012|priority 3 |Q3|Unknown|Unknown|Damage on pipe to accumulator.|NOPT NOTE NOCO|Damage on tubing to accumulator.|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Other causes/damage |QN Cancelled
ZF|100056443|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|FKS Quality system issues|Management Responsibility|FMC Other causes/damage |Planning error
ZB|P6000055605|14/09/2011|priority 2 |Q1|Unknown|Unknown|Correct to RAL 1004 in PRD-0000024062|NOCO NOPT ATCO NOTE|Procedure corrected to RAL 1004|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000039672|28/12/2015|priority 1 |Q3|Unknown|Unknown|ANOMALIA NA COLORAÇÃO.|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
Q3|100009059|13/03/2001|priority 1 |Q3|EXXONMOBIL|GOM|Observed water in silicone after H.test|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Tank test|Initial/Direct product problem|Leakage
ZF|P6000077638|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000024900|07/08/2013|priority 1 |Q3|Unknown|Unknown|DCV without the centralizer of th O'ring|NOTE NOCO ATCO NOPT|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |Cause not found
Q1|7100320|05/03/2002|priority 3 |Q1|PETROBRAS|Unknown|PLFD-150 card malfunction|NOPT NOTI NOCO|PTC-element on PLFD card damaged|Unknown|Unknown|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Damages
ZF|P6000105542|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 05  Bytting av PT'er.|NOCO ATCO NOPT NOTE|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000104111|16/05/2014|priority 3 |Q3|Unknown|Unknown|High flow restriction through HC53|NOCO ATCO NOPT NOTE|Loose metal part found in HP supp.header|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|Unknown|Too high cracing pressure on check valve|NOTE NOPT NOCO ATCO|Cracing pressure not verified on SCM|Assembly / Test related |Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Procedure error
Q3|7105129|05/06/2000|priority Unknown|Q3|Unknown|Unknown|SCM I 01|NOTI ATCO NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7102643|02/10/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 10 ÅsgA Y2-H PT Func.MV1 open malf.|NOTE NOPT ATCO NOCO|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
ZD|P6000132097|05/08/2016|priority 3 |Q2|Unknown|Unknown|cert issue(serialisation)|NOCO ATCO NOTE|Unknown|Marking | Marking Content Error|Object Types to Eng Matl CLASS|scm_mkIII|Vendor related |Clarification
ZF|100036936|03/06/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOCO ATCO NOTE NOPT|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|100035013|04/03/2009|priority 3 |Q3|SHELL|Unknown|SCM 13 not comunication with SPCTU|NOCO NOPT NOTE|See QN no 200120994|FMC Other Defect |Unknown|FKS Quality system issues|Noncompliance to Industrial Standard|Other external causes |Unknown
ZF|P6000083428|01/08/2013|priority 1 |Q3|Unknown|Unknown|Leaking Valve on SCM|ATCO NOCO NOTE|Unknown|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000100953|28/11/2013|priority 3 |Q3|Unknown|Unknown|To short threads in outercan|NOPT NOCO NOTE|Interface with EC adapter not verified|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
ZF|7102643|22/03/2010|priority 4 |Q3|STATOIL|NORTH SEA|F&D 16 Socket left on SCM|NOPT ATCO NOCO NOTE|Socket left on SCM|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Final Inspection error
ZF|P6000064909|11/02/2014|priority 1 |Q3|TOTAL|NORTH SEA|SCM#5 unusual value for PT16|NOCO ATCO NOTE|Unstable PT readings  S1 300408311|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZB|100035118|23/05/2016|priority 1 |Q1|Unknown|Unknown|Vincent WOCM DCV Leak Test|NOPT NOCO ATCO NOTE|Contamination during test|TEST |Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZB|100049000|22/05/2009|priority 2 |Q1|Unknown|Unknown|DHFC SCM 05 RAM Warning|NOCO NOTE|Defective RAM chip|Change/Deviation Request |Part substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|100035014|09/05/2005|priority 1 |Q3|SHELL|Unknown|SCM not able to install or pull off|NOPT NOTE NOCO ATCO|Chatter marks might be root cause.|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|MIssing batch numbers|NOPT NOTE NOCO|Unknown|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P7000039672|26/02/2016|priority 1 |Q3|Unknown|Unknown|Não Atendimento do Critério Hiperbárico|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000108469|27/05/2014|priority 3 |Q3|Unknown|Unknown|Wrong routing file on N: Drive|NOCO NOPT NOTE ATCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|Network config|FMC Engineering related |Engineering Error
ZF|P7000008275|31/03/2010|priority 2 |Q3|Unknown|Unknown|SCM TBU 03|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|100037967|09/11/2006|priority 3 |Q3|Unknown|Unknown|MCM Lock/Unlock marking difficult to see|NOCO NOTE ATCO NOPT|MCM Funnel orientation on Manifold|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|7103233|11/05/2007|priority 2 |Q3|Unknown|Unknown|Unknown|NOTE NOCO NOPT|Unknown|FMC Other Defect |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
Q3|7101172|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM sand detector sensors no readings|NOPT NOCO NOTI ATCO|SIO card had not been upgraded at Kitron|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Function
ZF|P6000068912|12/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|7103382|07/06/2018|priority 3 |Q3|Unknown|Unknown|SCM  Problem filling nitrogen on SCM.|ATCO NOTE NOCO|Procedure updated with Pn for tool.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000104111|10/06/2014|priority 4 |Q3|Unknown|Unknown|Damage parts|NOPT NOTE ATCO NOCO|Damaged during dissassembly|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Operator Error
ZE|P6000068912|26/04/2015|priority 2 |Q3|Unknown|Unknown|Markup SCM/SRM HFT/PSM  Luanda Workshop|NOCO ATCO NOTE|Documents updated|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT ATCO NOTE NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
Q3|3794920|24/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|Readings unstable from ext. sensors|NOCO NOPT NOTI ATCO|DHI card fault|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Statfjord C|Initial/Direct product problem|Function
ZB|100048038|27/09/2007|priority 2 |Q1|AGBAMI|Unknown|No communicate with SEM B (address 530)|NOTE NOCO|Defective Tantal Capacitor C25|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Modem PCBs|Vendor related |Component error
ZF|100016711|11/11/2003|priority 3 |Q3|BP|GOM|Lee Plug has loosened|NOTE NOCO NOPT|Engineering failure|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Hydraulic manifolds|FMC Engineering related|Design Specification/Drawing error
ZF|100026567|24/06/2004|priority Unknown|Q3|Unknown|Unknown|Use of wrong technical document|NOPT ATCO NOCO NOTE|Document not linked correctly|Operator did not see version indicator|Assembly / Test related |Miscellaneous|FKS Quality system issues|FKS Quality system issue|FMC Engineering related|Material Master/DBI error
ZF|100017278|08/02/2013|priority 2 |Q3|Unknown|Unknown|Wrong PN in BOM for SCM PN 100017278|NOCO NOTE ATCO|Wrong parts in stock  due to DBI error|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DBI error
ZF|P6000102687|09/03/2015|priority 1 |Q3|Unknown|Unknown|WOCM installed with plastic protection|NOPT NOTE ATCO NOCO|Protection caps not removed|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Improper handling
ZF|100046387|05/02/2015|priority 3 |Q3|Unknown|Unknown|CITV and MPFM test in FAT|ATCO NOCO NOTE NOPT|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100001156|24/05/2006|priority 3 |Q3|STATOIL|NORTH SEA|Too high voltage supplied to SCM|NOTE NOPT NOCO ATCO|Too high voltage supplied to SCM|Damage |Damage during testing|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Assy |Operator Error
ZB|100056261|01/02/2010|priority 2 |Q1|Unknown|Unknown|SCM Alarms and loss of Comms to SCMs|NOTE NOCO ATCO|SCM Alarms and loss of Comms to SCMs|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Test |Damaged during testing
ZF|100037965|22/03/2008|priority 1 |Q3|BP|Unknown|FPSO NCR 27 - Com. Issues on SEM A/B|ATCO NOTE NOCO NOPT|Unknown|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|P6000063531|07/03/2011|priority 2 |Q3|Unknown|Unknown|Availability of NAXYS/ALD simulator|NOTE NOCO NOPT ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100001156|08/09/2014|priority 2 |Q3|Unknown|Unknown|Reduction of mobilization scope|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000042308|11/06/2009|priority 4 |Q3|TULLOW|WEST AFRICA|Framo MPFM incompatibilities|ATCO NOCO NOTE|Framo MPFM incompatibilities|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|P6000104112|27/09/2018|priority 4 |Q3|Unknown|Unknown|Concession to deviate from procedure|NOTE ATCO NOPT NOCO|Unknown|TEST |Test Omitted|Object Types to Eng Matl CLASS|scm_mkIII|Test |Tool out of Calibration
ZD|P6000055605|11/04/2013|priority 3 |Q2|Unknown|Unknown|PROBLEM WITH COMM. - SCM315 SEM B.|ATCO NOPT NOTE NOCO|Problem With Comm. SEM B.|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Manufacturing Engineering|ME programming
ZF|P6000101955|06/07/2014|priority 3 |Q3|STATOIL|NORTH SEA|2- Drained sil. fluid in SCM S/N 2 and 3|ATCO NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZB|P6000088604|29/07/2016|priority 3 |Q1|Unknown|Unknown|Chevron  SCM  Warranty Claim|NOPT NOCO NOTE ATCO|Unknown|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Singapore
ZF|P7000001621|04/06/2012|priority 1 |Q3|Unknown|Unknown|PT de LP danificado durante montagem|NOCO NOTE NOPT ATCO|PT danificado ( reparo hercules)|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM S/N 11 G-2H GFA PT MV2-Open(manif.)|ATCO NOCO NOTI NOPT|PT|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|100048038|31/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|Trafo problems on Agbami S/N 28|ATCO NOTE NOCO NOPT|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100048038|08/11/2006|priority 3 |Q3|AGBAMI|Unknown|Nitrogen leakage internal|NOPT NOCO NOTE ATCO|fitting not tightened enough|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|3812476|12/04/2002|priority 3 |Q3|STATOIL|NORTH SEA|Forurensning fra XT under HFT|NOPT NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Change of pressure transducers|ATCO NOPT NOTE NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
Q3|7100320|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrade Hercules SCM 18|NOPT NOTI NOCO ATCO|Aluminium washers in solenoids|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|7104075|21/06/2005|priority 3 |Q3|MARUBENI|GOM|SCM INTERNAL  PT  FAILURE|NOCO NOPT NOTE ATCO|Internal PT failure|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100052701|03/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|Operation problems during FAT|NOTE ATCO NOPT NOCO|Error to be confirmed in QN200124450|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Unknown
ZF|P6000079984|10/04/2012|priority 3 |Q3|EXXONMOBIL|NORTH ATLANTIC|Problems with DHI 205|NOTE NOPT ATCO NOCO|DHI not configured for specific project|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Incorrect set up/testing
ZF|P7000000897|02/10/2012|priority 2 |Q3|Unknown|Unknown|SCM - SEM LEITURA|NOTE NOCO NOPT ATCO|PN P7000031845  - PO 47353105|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100036936|26/02/2008|priority 2 |Q3|STATOIL|NORTH SEA|No final inspection performed on SCM|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZE|100035118|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|NOTE ATCO NOCO NOPT|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZE|P7000001621|18/04/2018|priority 4 |Q3|Unknown|Unknown|MMR - Compensator Bladder Leakage|OSTS OSNO|Inspeção visual não identificou rebarba|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_components|Assembly |Lack of Awareness
ZE|P7000039672|30/08/2018|priority 2 |Q3|Unknown|Unknown|Anomalia na leitura do PT55 pela SEM A|OSTS OSNO|Anomalia na leitura do PT55 pela SEM A|Unknown|Unknown|SS - Controls -Instrumentation|SCM Pressure Transmitter|Test |Component Malfunction
ZF|P6000105542|29/07/2014|priority 3 |Q3|Unknown|Unknown|Flow restriction in SCM HP supply header|NOCO NOPT ATCO NOTE|Error during manuf. of M.B|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000098616|11/06/2013|priority 1 |Q3|Unknown|Unknown|Silicone drainport loose.|NOTE NOCO|Drain port not torqued  see RCA.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
Q3|3812476|08/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM press. transm. faults well C4-H|NOTI NOCO ATCO NOPT|DC/DC converter in AI-150 card|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
ZF|100048038|03/05/2006|priority 2 |Q3|Unknown|Unknown|Change of IWC Compensation|ATCO NOCO NOPT NOTE|Unknown|Change/Deviation Request |Part substitution request|FKS Quality system issues|Quality Management System|FMC Engineering related |DWG Error
Q3|7101172|20/12/2000|priority 3 |Q3|Unknown|Unknown|Communication errors with SCM (Subsea)|NOPT NOCO ATCO NOTI|PLMS card defective/card replaced|103-Electrical|Modems/Communications|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Function
ZF|100050383|15/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|Diode missing between SEM A and SEM B|NOTE NOPT NOCO ATCO|Missing diode-coupling in DO-outputs|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000088751|19/09/2012|priority 1 |Q3|Unknown|Unknown|QAM to FSK - Make 150 Startup permanent|NOTE NOCO NOPT|Unknown|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Engineering related |Engineering Error
ZD|P6000028371|25/02/2015|priority 3 |Q2|Unknown|Unknown|Coating specifications|ATCO NOCO NOTE NOPT|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|100031223|09/02/2015|priority 2 |Q3|Unknown|Unknown|Missing GA Drawing for SCM PN 100031223|NOPT ATCO NOTE NOCO|DWG linked to P/N|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000063531|19/06/2018|priority 2 |Q1|Unknown|Unknown|DHG Configuration (Emerson|NOTE NOPT NOCO ATCO|Unknown|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Planning error
ZF|100030542|26/04/2015|priority 1 |Q3|Unknown|Unknown|SCM bladder issue|NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Unqualified Vendor used
ZB|100052850|19/08/2009|priority 2 |Q1|REPSOL|Unknown|REV Com: Lack of comm. with SEM A in SCM|NOTE NOCO ATCO NOPT|Unknown|FMC Other Defect |Unknown|Customer Compliant|Noncompliance to Customer Requirement|Other external causes |Customer Error/responsibility
ZF|P7000024900|04/06/2013|priority 1 |Q3|Unknown|Unknown|DAMAGE ON THE THREAD|ATCO NOTE NOCO NOPT|115215 - TESS DRAMMEN AS  AVD. KONGSBERG|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Final Inspection Error
ZF|P6000105542|21/10/2013|priority 3 |Q3|Unknown|Unknown|Bad thread check valve|NOTE ATCO NOCO NOPT|Bad threads on check valve|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZE|100017997|02/09/2010|priority 1 |Q3|Unknown|Unknown|SCM EC port corrosion|NOTE NOCO ATCO NOPT|Unknown|Unknown|Unknown|Customer Compliant|Unsatisfactory Customer Satisfaction|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000093498|07/04/2014|priority 4 |Q3|Unknown|Unknown|Cant mount the valves isnt space enough|ATCO NOPT NOTE NOCO|Lack of interface check prior to release|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000043122|19/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Material not delivered to plant|NOPT NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|100048038|21/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|Customer request change in Flow Restrico|ATCO NOCO NOPT NOTE|Customer Requested Change|Change/Deviation Request |Process substitution request|FKS Quality system issues|Product Realization|Other external causes |Customer Error/responsibility
Q3|7102969|Unknown|priority 3 |Q3|Unknown|Unknown|Feil i prosedyre om change over valve.|NOCO NOPT NOTI ATCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZE|P1000018406|08/11/2010|priority 3 |Q3|BP|GOM|Escape: Assembly/ QC- Wrong N/A FAT proc|OSTS NOCO DLFL NOPT|Traiing|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
Q3|7105129|10/04/2000|priority Unknown|Q3|Unknown|Unknown|SCM I 01|NOPT NOCO ATCO NOTI|Wrong thickness on anodes|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Dimension
ZF|P7000024900|02/12/2013|priority 2 |Q3|Unknown|Unknown|FALTA DE ORING NO COUPLER|NOPT ATCO NOTE NOCO|1242 - HTS maskinteknikk as|FMC Other Defect |Part Lost|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Missing Parts
ZF|100066325|15/12/2012|priority 1 |Q3|Unknown|Unknown|SCM interface showing signs of corrosion|ATCO NOPT NOCO NOTE|SCM interface showing signs of corrosion|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Packaging/Handling
ZF|P6000116166|19/11/2014|priority 3 |Q3|Unknown|Unknown|Dirty retur compensator|NOCO ATCO NOPT NOTE|Outside cleanliness requirement|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Compensator|Vendor related |Specification not followed
ZF|100035014|23/10/2012|priority 4 |Q3|Unknown|Unknown|Failed to call in customer to witness FA|NOTE NOPT ATCO NOCO|Customer witness not informed|FMC Other Defect |Functional|FKS Quality system issues|Quality Management System|QA/QS/QI Related|Final Inspection error
ZF|P6000068924|14/12/2011|priority 3 |Q3|TOTAL|Unknown|Problem with CWDM|ATCO NOCO NOTE NOPT|Replaced according to QN200238941|Raw Material |OBS-Incorrect Material|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZD|P6000084242|21/12/2011|priority 1 |Q2|CONOCOPHILLIPS|Unknown|(SS) Error on SCM Name Plate|ATCO NOCO NOPT NOTE|Marking error on name plate|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|7100320|05/09/2003|priority 3 |Q3|PETROBRAS|Unknown|SCM 19 Herc. SEMA AI/SEMB DC/DC failure|NOTE NOCO NOPT ATCO|AD converter with known weakness.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|I/O PCBs|Vendor related|Component error
Q3|7101172|Unknown|priority 3 |Q3|Unknown|Unknown|kommunikasjonsfeil på rack.|NOTI NOCO ATCO NOPT|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|100026567|31/10/2003|priority 3 |Q3|Unknown|Unknown|Difference on drawings regarding marking|NOPT NOCO ATCO NOTE|Missing marking on assy dwg|Assembly / Test related |Marking|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Engineering related|Design Specification/Drawing error
ZF|100037428|20/02/2006|priority 2 |Q3|TOTAL|WEST AFRICA|SCM production error - ROSA P3 XT|ATCO NOTE NOPT NOCO|Damaged during field-testing.|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000069820|10/01/2012|priority 1 |Q3|CONOCOPHILLIPS|Unknown|(SS) MRM Software Version update|ATCO NOCO NOTE|MRM Software Version update|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|GFA Bundle(Haliburton) IR very low|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZB|100018600|30/04/2004|priority 3 |Q1|PETROBRAS|Unknown|Water found in dielectric fluid|NOCO NOPT ATCO NOTE|Leak in vacuum port plug.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Assembly/Test related|Assembly/Test error
ZF|P6000055605|24/08/2012|priority 3 |Q3|Unknown|Unknown|filling port check valve missing|NOPT NOTE NOCO|Filling port not assembled in mech assy.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Assy |Operator Error
ZF|P6000065886|15/12/2010|priority 2 |Q3|Unknown|Unknown|Akkumulator assy må rettes opp|NOPT NOTE NOCO|Design error on DWG|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Engineering related |DWG Error
ZB|P6000091085|06/05/2015|priority 2 |Q1|Unknown|Unknown|Shell OWIRS Claim 002 SNTBD (PSD)|NOTE NOCO ATCO|Component error|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Equipment Malfunction
ZF|P6000068912|21/11/2012|priority 3 |Q3|Unknown|Unknown|Additional  testing SEM|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |No Non-Compliance
Q3|3801623|03/01/2001|priority 2 |Q3|Unknown|Unknown|Collet Connector needs refurbishment|ATCO NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Cleanliness
ZF|100054943|18/09/2007|priority 3 |Q3|Unknown|Unknown|Incorrect SEM adresses|NOTE NOPT NOCO ATCO|Missed single address in series|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|7102969|05/04/2007|priority 2 |Q1|Unknown|Unknown|SCM unable to access and send +30VDC|NOTE NOCO ATCO|Electronic component interface issue|Assembly/Test Related |Interface of components issue|Subsea sensors (not in SCM)|Pressure Transmitter (PT)|FMC Engineering related |Lack of Training
ZF|100037427|26/12/2006|priority 1 |Q3|TOTAL|WEST AFRICA|no communication on SEM B|NOPT NOTE ATCO NOCO|Activity transferred to SN300117777|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes |QN Cancelled
ZF|P6000123495|09/02/2016|priority 1 |Q3|Unknown|Unknown|CV to be changed out on SCM|NOTE ATCO NOCO|Unknown|FMC Other Defect |Functional|SS - Compl. & W.Over - XT - General|Tree Assembly|Vendor related |Specification not followed
Q3|3812476|06/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  DHI card on SEM A not functioning|ATCO NOCO NOPT NOTI|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
ZB|P6000065886|24/04/2012|priority 1 |Q1|ENI|NORTH SEA|Problem with communication|ATCO NOTE NOCO|Faulty board|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000063632|23/12/2010|priority 1 |Q3|AQUILA PHASE 2|Unknown|CPU600 improving startup on long umbilic|NOTE NOCO ATCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZE|P6000104112|18/09/2015|priority 2 |Q3|Unknown|Unknown|Name plate has wrong max VAC|NOTE NOCO ATCO|Engineering error  marking on name plate|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000126219|15/11/2016|priority 3 |Q3|Unknown|Unknown|PT's increased after storage of SCM|NOTE NOCO NOPT ATCO|High values on PT|TEST |Component Error|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Other causes/damage |Cause not found
ZF|P6000042969|25/11/2010|priority 2 |Q3|Unknown|Unknown|Feil plukk av hydralic  plug hex hea|NOCO NOTE|Picking fault in warehouse|FMC Other Defect |Part Lost|SS - Controls -SCMMB|Other hydraulic components|Intercompany|FMC Kongsberg
ZF|100018531|07/05/2010|priority 1 |Q3|Unknown|Unknown|Mecanismo de travamento|NOTE NOCO ATCO|Erro no isolamento da Extension Rod|Coating/Plating |Coating defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Paintshop Related|Operator error
ZF|P6000079984|22/11/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000069056|30/11/2012|priority 3 |Q3|Unknown|Unknown|Voltage is beyond the criteria|NOTE NOPT NOCO ATCO|voltage drop due bad Faston cable-conn.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|P6000042969|24/06/2011|priority 1 |Q3|TOTAL|WEST AFRICA|LP1 and LP2 is leaking oil|NOCO NOPT NOTE ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Other causes/damage |Cause not found
ZF|100048038|18/12/2006|priority 3 |Q3|CHEVRON|WEST AFRICA|Water inside SCM after hyperbaric test|NOCO ATCO NOPT NOTE|PT hose not tighten enough|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|7104670|Unknown|priority Unknown|Q3|Unknown|Unknown|SCM Sn.01|NOCO NOTI NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7102643|28/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|Low IR values on SCM SEMB  well J-3H|NOCO NOPT NOTI ATCO|PLFS160 card damaged|103-Electrical|SEM Powersupply|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|100050519|29/11/2007|priority 2 |Q3|Unknown|Unknown|SCM accumulator|ATCO NOTE NOCO|Unknown|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZC|100020562|06/10/2005|priority 2 |Q2|BP|GOM|SCM Bladder burst (QTY5)|NOTE NOCO ATCO NOPT|"2 root causes  see text in ""follow up"""|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100025661|20/03/2006|priority 3 |Q3|SHELL|GOM|Damaged Bladder|NOPT ATCO NOTE NOCO|Bladder Failure|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZD|7104075|11/11/2014|priority 3 |Q2|Unknown|Unknown|ECs failed roughness inspection|NOCO ATCO NOTE NOPT|Unknown|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|100037428|30/12/2007|priority 1 |Q3|TOTAL|WEST AFRICA|No communication with DHG|ATCO NOPT NOCO NOTE|faulty CPU card|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|100037428|10/05/2007|priority 2 |Q3|TOTAL|WEST AFRICA|Failed PT53 on SCM #9|NOPT NOTE NOCO|Unknown|Damage |Wear & Tear|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Vendor audit related|Unknown
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-017: RAM Warning Error|NOTE NOCO|Error Message|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|Rosa 401 invalid pressure sensor reading|NOCO NOTE|Unknown|FMC Other Defect |Unknown|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Unknown
Q3|7100320|03/11/1999|priority 3 |Q3|PETROBRAS|Unknown|Failure on SCM sn. 4 adress 4B|NOCO NOPT NOTI ATCO|Failure of AIDO board in SCM|Failure of AIDO board in SCM|Failure of AIDO board in SCM|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Function
ZF|7102969|26/05/2006|priority 3 |Q3|Unknown|Unknown|Wrong nipple PN on MEGI Phase II SCM BOM|NOPT NOTE NOCO ATCO|BOM Error|Design |Material Master Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000083428|15/08/2012|priority 3 |Q3|Unknown|Unknown|Wrong o-rings|ATCO NOCO NOTE NOPT|Wrong O-rings in Outercan BOM|Design |Material Master Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Specification error
ZF|P7000024191|12/12/2012|priority 1 |Q3|Unknown|Unknown|Leakage out of acceptance criteria|NOPT NOCO NOTE ATCO|1659 - Oceaneering Rotator - SN 72173|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|100037428|11/04/2011|priority 1 |Q3|TOTAL|WEST AFRICA|Down Hole Gauge testing failure with SCM|NOPT NOTE NOCO|DHG cards|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Intercompany|FMC Kongsberg
Q3|7102643|06/12/1999|priority 3 |Q3|STATOIL|NORTH SEA|Åsg SCM 24  AWV PT not working well I2-H|NOTI ATCO NOCO NOPT|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|100035400|28/11/2007|priority 1 |Q3|WALTER|GOM|New Pod Software to be downloaded.|NOPT NOCO NOTE ATCO|New Pod Software to be downloaded.|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P7000000897|19/06/2012|priority 1 |Q3|SHELL|Unknown|SEM B communication failure|NOCO NOPT NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|P6000076121|15/11/2011|priority 3 |Q3|CNOOC|Unknown|Chips found inside the HP-Config Plug|NOTE NOCO ATCO|Plugs not cleaned by supplier.|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|100031193|05/01/2004|priority 3 |Q3|Unknown|Unknown|FAIL WITH CHECK VALVES|NOPT NOTE ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100037229|15/08/2005|priority 3 |Q3|PETROBRAS|Unknown|SCM stuck in EHXT|ATCO NOCO NOTE NOPT|No failure found on parts|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P6000028371|25/02/2008|priority 3 |Q3|SHELL|GOM|Batch numbers missing in iBASE list|NOTE NOCO NOPT|Change: batch cert. to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|7102643|17/02/2000|priority 3 |Q3|Unknown|Unknown|SCMs  7L of silicone oil drained out|NOCO NOPT NOTI ATCO|Important notice attached to wrong SCM|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Documentation
Q3|7102643|04/01/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  communication failure SEM B (Y1-H)|ATCO NOTI NOCO NOPT|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|P7000024900|08/08/2014|priority 1 |Q3|Unknown|Unknown|Arranhão na adapter plate CVLP|NOTE NOCO ATCO NOPT|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Damage during transport
ZD|P6000066700|24/11/2010|priority 1 |Q2|Unknown|Unknown|CERT ISSUE/WRONG PART|NOPT ATCO NOTE NOCO|VL-INCORRECT CERTS|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZF|P6000064909|20/03/2012|priority 3 |Q3|Unknown|Unknown|Change of Hydraulic Fluid in LT prod 10|NOTE NOCO|Hydraulic Fluid change in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100068622|28/10/2014|priority 3 |Q3|Unknown|Unknown|SCM not according to Bills of Material.|ATCO NOTE NOCO|Part obsolesce  replaced with new P/N|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000068912|28/11/2012|priority 3 |Q3|Unknown|Unknown|Silicon pressure will not follow|NOCO ATCO NOTE NOPT|Grease inside the gauge port (baseplate)|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000068902|20/09/2011|priority 3 |Q3|Unknown|Unknown|Wiring error|NOPT ATCO NOCO NOTE|Human error  process not maintained|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000000897|17/10/2011|priority 1 |Q3|SHELL|Unknown|Downhole failure of DHI 113.|NOCO NOTE ATCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|Other external causes |Customer Error/responsibility
ZF|7103382|10/03/2004|priority 3 |Q3|Unknown|Unknown|BOURI SCSSV hyd leak /stuck possition|ATCO NOCO NOTE NOPT|See attached Report|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Unknown
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-016: RAM Warning Error|NOTE NOCO|Error Message|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|100056261|22/02/2011|priority 2 |Q3|MURPHY|WEST AFRICA|Missing Engineer Sign offs|NOCO ATCO NOTE NOPT|Section not N/A'd|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av Pressure transmittere.|NOPT NOCO NOTE ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|100037426|02/05/2005|priority 3 |Q3|TOTAL|WEST AFRICA|Corrosion on serrated lock washers|NOTE NOCO NOPT|Unknown|Coating |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100027228|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|Silicon Leakage on SCM  SN 5 6134 SVAN|ATCO NOCO NOPT NOTE|Root cause unknown.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Engineering related |DWG Error
ZF|100050383|09/05/2007|priority 4 |Q3|STATOIL|NORTH SEA|Replace control valves on TORDIS|NOCO ATCO NOPT NOTE|Unknown|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Engineering related |Engineering Error
Q3|7101172|18/09/2000|priority 2 |Q3|STATOIL|NORTH SEA|Leak under SCM when operating SIV (D-3H)|NOTI NOCO ATCO NOPT|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZF|P7000024900|30/07/2013|priority 1 |Q3|Unknown|Unknown|Check valve out of acceptance criteria|ATCO NOCO NOTE NOPT|1242 - HTS Maskinteknikk AS|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZE|P6000121268|27/03/2015|priority 4 |Q3|Unknown|Unknown|(CDM)SCM EC6 Damage - ENI Jangkrik|NOTE ATCO NOCO NOPT|Electrical connector damage|Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|El. Connector|FMC Test |Damaged during testing
ZF|P6000088604|08/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000043766|19/06/2009|priority 2 |Q1|PETROBRAS|Unknown|Communication to Pig Detector|NOPT NOCO NOTE ATCO|Communication To Pig Detector|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZE|100051992|04/05/2013|priority 2 |Q3|Unknown|Unknown|Vincent - SC  Issue|NOCO NOTE NOPT ATCO|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZB|100068622|02/03/2017|priority 1 |Q1|Unknown|Unknown|No contact w/gauges SCM PN100068622 SN10|NOPT NOTE ATCO NOCO|RFQ incomplete|Documentation Requirement |Incorrect user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|3787102|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|Lekkasje mellom solenoide og pilot|NOTE NOCO NOPT ATCO|Screw not tightened / not correct screws|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Operator Error
ZF|P6000101955|03/02/2014|priority 3 |Q3|Unknown|Unknown|Wrong subnet adress on subsea routers|NOPT ATCO NOTE NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|Network config|FMC Engineering related |Engineering Error
ZF|P6000105542|07/07/2014|priority 3 |Q3|Unknown|Unknown|EC adapter don`t fit.|NOCO NOTE NOPT ATCO|Hole pattern outside of specification|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000064909|25/05/2011|priority 3 |Q3|TOTAL|NORTH SEA|Wiring error and cut on hose from EC5|NOCO NOPT NOTE|Follow up in ZF QN:200209938|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Machine Shop Personnel |Operator error
ZF|P7000039672|08/10/2013|priority 1 |Q3|Unknown|Unknown|ECN  6147855 - PN  P7000039672|NOPT NOTE ATCO NOCO|ECN|Design |DBI Error|SS - Controls -Hydraulic Distribution|Other hydraulic components|FMC Engineering related |ECN Change
ZF|P6000102554|08/01/2014|priority 3 |Q3|Unknown|Unknown|MISSING BOLTS ON EC ASSY|NOTE ATCO NOCO NOPT|Bolts lost in FMC wearehouse/workshop|Procurement |Incomplete Kit Of Parts|SS - Controls - Electric/Optical Jumpers|Other Electric/Optical Products|FMC Fabrication Shop Personnel |Improper Handling
ZF|P6000028371|31/07/2009|priority 1 |Q3|SHELL|GOM|Lock/Unlock indicator line on SCM|NOTE NOPT ATCO NOCO|Unknown|Marking |Marking Location Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Operator Error
Q3|3812476|08/02/2001|priority 3 |Q3|Unknown|Unknown|SCM  DH press/temp. sensor malfunction|NOPT NOCO ATCO NOTI|Not known  Service Notification?|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
ZF|P7000000897|06/12/2012|priority 2 |Q3|Unknown|Unknown|PERDA DE COMUNICAÇÃO COM  A SEM A|NOPT NOTE ATCO NOCO|Sem evidência da causa|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000000897|09/01/2012|priority 1 |Q3|Unknown|Unknown|Coupler vazando|NOPT NOTE NOCO ATCO|HTS MASKINTEKNIKK AS|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Products|Coupler|Vendor related |Equipment Malfunction
ZF|P6000108984|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100035118|14/03/2005|priority 2 |Q3|PETRONAS|Unknown|Leakage in SCM.|NOPT NOTE ATCO NOCO|Contaminated hydraulic fluid|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Other external causes |Customer Error/responsibility
Q1|7102643|Unknown|priority 1 |Q1|Unknown|Unknown|PT for SIV not working  Ågotnes|NOPT NOCO ATCO NOTI|PT failure  PT replaced|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZF|P6000060453|29/03/2010|priority 3 |Q3|HEIDRUN NORTH|Unknown|Nitrogen leakage inside SCM|NOCO ATCO NOTE NOPT|Nitrogen leakage due to loose fitting|Test Related |OBS-Leakage (gas)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000058949|08/02/2010|priority 3 |Q3|Unknown|Unknown|Wrong tubing in BOM|NOPT NOCO NOTE ATCO|Design error  wrong material specified|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO NOPT NOTE ATCO|ECN 7058839 - P7000017839|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|100048038|17/08/2008|priority 3 |Q1|CHEVRON|Unknown|SCSSV 1 PT reading improperly|NOPT NOTE NOCO|Unknown|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P6000069056|06/03/2012|priority 2 |Q3|STATOIL|NORTH SEA|Recalibration of  cards|ATCO NOCO NOTE|Most likely irregularities in test setup|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100001156|08/04/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOTE NOPT ORAS ATCO NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100037428|16/05/2011|priority 3 |Q3|Unknown|Unknown|Extertnal 4-20ma sensors not working|ATCO NOTE NOCO NOPT|FMC opr mistake during SCM wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000064911|14/12/2011|priority 3 |Q3|TOTAL|Unknown|Problems with CWDM|NOTE NOCO ATCO NOPT|Follow-up in QN200238941&200238942|Raw Material |OBS-Incorrect Material|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZF|P6000104114|19/01/2015|priority 3 |Q3|Unknown|Unknown|Faulty wiring on secondary side of TA1|ATCO NOCO NOPT NOTE|SCM wiring fault (opr error)|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|P6000088751|30/08/2016|priority 3 |Q1|Unknown|Unknown|FMC Quality Rep not witnessing SCM FAT|NOPT NOCO NOTE ATCO|Misaligned H and W presence duration|Documentation Requirement |Other- Specify in comments|FKS Quality system issues|Quality Management System|Intercompany|FMC Kongsberg
ZB|P6000088751|10/04/2018|priority 3 |Q1|Unknown|Unknown|GWF-2/Transportation Issue|NOTE ATCO NOCO|No Procedure in place|FMC Other Defect |Physical|Object Types to Eng Matl CLASS|scm_mkIIE|Documentation Requirement |Other- Specify in comments
ZF|P6000110991|07/11/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|NOCO ATCO NOTE NOPT|CPI SPCTU and config not available.|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Missed operation
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT ATCO NOCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|P6000043122|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM SSS 03|NOPT NOTE NOCO|New SW downloaded  QN cancelled|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Other causes/damage |QN Cancelled
ZF|100048038|04/01/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|Leak from IWC return|ATCO NOTE NOPT NOCO|failure to put Loctite on threads|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000079032|24/01/2012|priority 3 |Q3|Unknown|Unknown|PSD A card  doesn't  boot|NOCO NOTE NOPT|Opr.failure caused SCM wiring error|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|BURNT RESISTOR ON AICF BOARD|NOCO NOTE ATCO NOPT|BURNED RESISTOR ON AICF BOARD|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P7000016420|05/12/2011|priority 1 |Q3|PETROBRAS|Unknown|Revestimento não conforme.|NOCO ATCO NOTE NOPT|Revestimento|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|QA/QS/QI Related|Final Inspection error
ZB|100020562|20/02/2009|priority 1 |Q1|BP|GOM|SEM A not responding|NOPT ATCO NOCO NOTE|No Non-conformance|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |No Non-Compliance
ZF|P7000001843|03/02/2011|priority 1 |Q3|Unknown|Unknown|Funcionamento de sensor - Flow meter|NOTE NOPT NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZB|100017278|29/09/2008|priority 3 |Q1|STATOIL|NORTH SEA|Leakage in solenoide valve in SCM|NOPT NOCO NOTE ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Unknown
ZF|100050383|19/06/2013|priority 2 |Q3|STATOIL|NORTH SEA|Lack of external test equipment|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100049000|26/04/2010|priority 1 |Q3|BP|Unknown|Incomplete databook|NOPT NOCO NOTE ATCO|Incomplete databook - missing signatures|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
Q3|100018600|24/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|The centre rod is slow to operate|NOPT NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000042308|06/11/2009|priority 2 |Q3|Unknown|Unknown|Remove SCM & send to CS|NOTE NOPT ATCO NOCO|Unknown|Change/Deviation Request |Process substitution request|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |No Non-Compliance
ZB|7104075|10/03/2009|priority 1 |Q1|MARUBENI|GOM|Loss of Communication SEM-A|NOPT NOTE NOCO ATCO|Loss of Communication SEM-A|FMC Other Defect |Functional|Subsea Control Module (SCM) Electrical|Power supply|Vendor related |Equipment Malfunction
Q3|100018600|28/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|B electronic don't switch off MFM power|ATCO NOCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q2|7104020|Unknown|priority 3 |Q2|Unknown|Unknown|Change of solenoids|ATCO NOTE NOPT NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|7101401|01/06/2004|priority 2 |Q3|PETROBRAS|Unknown|Marlim SCM Extencion Rod|NOPT NOTE ATCO NOCO|Wrong P/N in spare part list|Assembly / Test related |Part Incorrect|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Engineering related|Design Specification/Drawing error
ZF|100018600|30/03/2005|priority 1 |Q3|PETROBRAS|Unknown|East Marimba Manifold. SCM A  SEM B.|NOPT NOCO ATCO NOTE|Electrical overstress in tantalum cap.|Assembly/Test Related |Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Engineering related |DWG Error
ZF|P6000063632|04/11/2010|priority 1 |Q3|Unknown|Unknown|Et rettur hull for mye i baseplata|NOPT ATCO NOCO NOTE|DWG error|Machining Related |OBS-Position Error|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Engineering related |DWG Error
ZF|3794920|17/01/2016|priority 3 |Q3|Unknown|Unknown|PT for Statfjord SCM MKI is obsolete|NOPT NOTE ATCO NOCO|Not able to purchase PN 3792826|Obsolescence Issue:&|Not Available|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Shelf Life Expiry
ZF|100036936|08/01/2005|priority 1 |Q3|Unknown|Unknown|SCM NSAT - SW fault|ATCO NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|100020562|03/08/2010|priority 3 |Q3|BP|GOM|Escape: Databook Incorrect|ATCO NOCO NOTE|Missing signatures|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Documentation error
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte solonoider på ventiler.|NOTI ATCO NOCO NOPT|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
Q3|3801623|04/11/1999|priority 3 |Q3|Unknown|Unknown|Control module skifting Heidrun  CM 11|NOTI NOPT ATCO NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Unknown|Unknown|Initial/Direct product problem|Damages
ZF|P6000068924|30/10/2012|priority 1 |Q3|Unknown|Unknown|Not able to switch off IXT7 and 8|NOTE NOPT NOCO|Coating has penetrated relay in PSDM600|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Coating Defect
ZF|100001156|08/11/2005|priority 3 |Q3|STATOIL|NORTH SEA|TESTING MED FEIL REV. PÅ PROSEDYRE|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7100320|02/12/1999|priority 3 |Q3|Unknown|Unknown|Upgrade Hercules SCM 16-GAMA to 16-OMEGA|NOTI NOPT NOCO ATCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZE|P7000024191|23/11/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Pin of Extension Rod Smashed|ATCO NOTE NOCO|Unknown|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Assembly |Improperly Protected
ZF|P6000079433|22/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|NOPT NOTE ATCO NOCO|Coupler Interface on m.block (spc error)|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Specification error
ZB|100041493|04/09/2009|priority 3 |Q1|STATOIL|NORTH SEA|F&D SCM for URT sent in wrong position|NOPT NOCO NOTE|Procedure not followed|FMC Other Defect |Physical|SS - Intervention - Running Tool|SCM Running Tool|FMC Other causes/damage |Planning error
ZF|P6000064910|02/12/2010|priority 2 |Q3|Unknown|Unknown|Feil i tegning for P6000065013 Mech Assy|ATCO NOCO NOTE NOPT|DWG error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZB|7103234|05/11/2014|priority 3 |Q1|Unknown|Unknown|NCR 313417 SCM Accumulator no pre-charge|ATCO NOPT NOTE NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Service Related:|Improper job preparation
ZF|100049000|21/06/2011|priority 1 |Q3|BP|Unknown|Investigate Coupler Rotation-BPAT SCM 27|NOTE ATCO NOCO NOPT|Investigate Coupler Rotation-BPAT SCM 27|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZB|100048038|09/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|SCM #1 PT51 (HP SUPPLY) SEM A FAILURE|NOCO NOTE|SCM #1 PT51 (HP SUPPLY) SEM A FAILURE|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|100030542|26/02/2004|priority 2 |Q3|Unknown|Unknown|Blind plug for silicon relief installed|NOCO NOTE NOPT|"""Important Notice"" not read/understood"|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Assembly/Test related|Operator error
ZB|7101401|Unknown|priority 3 |Q1|PETROBRAS|Unknown|P-35 - Vazamento de HW no Slot A|NOTI OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100027228|03/08/2005|priority 3 |Q3|STATOIL|NORTH SEA|Change of parts on locking mechanism.|ATCO NOTE NOCO NOPT|Unknown|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|100037130|06/12/2004|priority 1 |Q3|BOURI  FEAD|Unknown|Leakage of hydraulic oil in EFAT area|NOCO ATCO NOTE NOPT|SCM sprayed with Brayco in workshop|Assembly / Test related |Handling Damage|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Assembly/Test related|Miscellaneous
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|ureinheter i hydraulikksystem fra kunde|NOPT NOTE NOCO ATCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000110991|20/12/2013|priority 3 |Q3|Unknown|Unknown|Update BOM and Drawing|NOCO NOTE NOPT ATCO|Old SCM rebuild to SEM 615|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100051269|18/10/2013|priority 2 |Q3|STATOIL|NORTH SEA|Damage to SEM bracket and outercan tube|NOCO ATCO NOTE|outercan tubing damged during lifting|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|P6000121268|13/04/2015|priority 3 |Q3|Unknown|Unknown|Leakage test failed|NOTE NOCO ATCO NOPT|COV leaking outside acceptance criteria|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P7000039672|13/08/2014|priority 1 |Q3|Unknown|Unknown|Base Plate danificada|ATCO NOTE NOPT NOCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|P7000000897|05/04/2012|priority 1 |Q3|Unknown|Unknown|SRT Software|NOPT NOCO NOTE ATCO|delay in delivering for workshop test|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Purchasing Error
ZF|P7000039672|26/06/2018|priority 4 |Q3|PETROBRAS|Unknown|MMR - Broken Screw on Base Plate|NOCO ATCO NOTE|Incorrect Tool|Machining |Thread Error|Object Types to Eng Matl CLASS|scm_mkIIE|Machining |incorrect tool
ZF|100036936|01/09/2008|priority 3 |Q3|STATOIL|NORTH SEA|Scm not locked in skid.|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P7000039672|12/02/2014|priority 1 |Q3|Unknown|Unknown|Continuidade eletrica acima do critério.|NOPT ATCO NOTE NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |DBI error
ZF|P6000039844|30/08/2011|priority 1 |Q3|Unknown|Unknown|Use of HW540 for FAT instead of HW443|NOPT ATCO NOTE NOCO|Lack of Gumusut SCMTS at FMC Kongsberg|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000064911|01/08/2017|priority 2 |Q3|TOTAL|Unknown|Strainer contact to ground|NOPT ATCO NOCO NOTE|Extra isolation of strainer needed|Assembly |Other- Specify in comments|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Continuous Improvement
ZF|P6000064911|06/10/2014|priority 2 |Q3|Unknown|Unknown|Short-circuit in SRM4 SEM 1|NOTE NOPT ATCO NOCO|Damage due to Leakage in FiberOptic pen.|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Second tier supplier issue
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|Unknown|Gluing of DHI212 board|NOCO NOTE ATCO|WD design improvement.|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P7000024900|04/01/2013|priority 1 |Q3|Unknown|Unknown|RCA|NOPT NOCO NOTE ATCO|Falta de treinamento específico|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of training
ZF|P6000077638|04/02/2013|priority 1 |Q3|Unknown|Unknown|Order started w/o ITP ready|ATCO NOPT NOCO NOTE|Unclear roles/responsibility processes|Documentation |Procedure / Process Error|FKS Quality system issues|Quality Management System|QA/QS/QI Related|Documentation error
ZF|P6000104116|20/10/2014|priority 3 |Q3|Unknown|Unknown|Multiple distance housings missing paint|NOCO NOPT ATCO NOTE|Paint not applied acc. to dwg.|Coating/Plating |Painting Not Applied|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000068902|11/01/2015|priority 3 |Q3|Unknown|Unknown|check valve cap to be replaced|NOPT NOCO ATCO NOTE|Part substitution|Change/Deviation Request |Part substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Missing Parts
ZF|P7000024191|05/09/2012|priority 4 |Q3|Unknown|Unknown|LA TEST BOX - QN|NOTE NOCO ATCO NOPT|Lab test box with problem.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000039844|20/03/2009|priority 3 |Q3|SHELL|Unknown|CPU init. fails at Poweron  OK & Reset|NOCO NOTE NOPT|Error to be confirmed in QN200124450|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Unknown
ZF|3787102|08/12/2011|priority 2 |Q3|STATOIL|NORTH SEA|Snorre FD 15 Welding on deck w/ WCM|NOTE NOCO NOPT|Precipitate mobilization due to weather|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
Q1|7103233|27/02/2003|priority 3 |Q1|SUNCOR NGXT|Unknown|SCM flowmeter reading failure on SEM B|ATCO NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
ZF|P6000105542|20/09/2013|priority 3 |Q3|Unknown|Unknown|Config problem with CITV's|NOTE NOPT NOCO ATCO|Unknown|Design |Procedure Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZB|100035013|02/06/2015|priority 3 |Q1|Unknown|Unknown|Ormen Lange Claim SCM 22|NOTE ATCO NOCO|Unknown|Change/Deviation Request |Part substitution request|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Operator Error
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Oppgrader Marlim 01-ALFA til 01-GAMA|ATCO NOCO NOPT NOTI|Unknown|101-Mechanical|Mechanical Components|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|3812476|04/07/2007|priority 3 |Q3|STATOIL|NORTH SEA|Clash between the SCM and URT|NOPT NOTE NOCO|Mismatch between DWG and cable tray|Assembly/Test Related |Interface of components issue|SS - Intervention - Running Tool|SCM Running Tool|FMC Other causes/damage |Planning error
ZF|100049000|30/11/2010|priority 2 |Q3|BP|Unknown|Class 1 ECN 6083510|NOTE ATCO NOPT NOCO|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|100005667|12/02/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 226|NOTE ATCO NOCO|Bladder leak due to FMC error|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|3812476|28/07/2010|priority 3 |Q1|STATOIL|NORTH SEA|F&D23 Loose items on top of SCM|NOTE ATCO NOCO NOPT|Loose item not found during final inspec|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Final Inspection error
ZF|P6000088626|19/10/2015|priority 1 |Q3|Unknown|Unknown|Bandak used wrong lift-test procedure.|NOTE ATCO NOCO NOPT|No error from supplier|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000104112|04/04/2014|priority 3 |Q3|Unknown|Unknown|Re assemble FO on ESRS with clips|NOCO ATCO NOPT NOTE|Design improved  ref ECN6158709|Design |Drawing Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Continuous Improvement
ZD|P7000039672|28/07/2014|priority 2 |Q2|Unknown|Unknown|ECN:6164886 - PN:P7000039672 - CDM|NOPT NOTE NOCO ATCO|ECN:6164886 - PN:P7000039672 - CDM|Raw Material |OBS-Incorrect Material|FKS Quality system issues|Quality Management System|FMC Engineering related |ECN Change
ZF|100018531|23/04/2010|priority 1 |Q3|Unknown|Unknown|Falha de leitura de sensor externo|NOPT NOTE NOCO ATCO|cutted wire|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Damaged during assembly
ZF|100036936|22/04/2005|priority Unknown|Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOTE NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|3794920|28/02/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 57 SFC SEMB malfunction|NOCO NOTE NOPT ATCO|Unknown|103-Electrical|SEM El.Rack|Defect locations - offshore/field|Statfjord C|Initial/Direct product problem|Function
Q3|7101172|Unknown|priority 3 |Q3|Unknown|Unknown|GFS SCM 05  locking mechanism loosened|NOCO NOTI ATCO NOPT|Shear pin sheared  suspect over-torque|101-Mechanical|Mechanical Components|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Damages
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|Scratch in seal surf adjacent to o-ring|NOTI NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7105131|05/01/2001|priority Unknown|Q3|Unknown|Unknown|SCM M/MFM General|NOPT ATCO NOCO NOTI|Restrictors should be 1 instead of 2 mm|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Function
ZF|100046112|21/06/2013|priority 2 |Q3|Unknown|Unknown|No readings from ex.sensors on SEM B|ATCO NOCO NOTE|Follow up in SN300373234|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Intercompany|FMC Singapore
ZF|P6000150910|11/09/2018|priority 3 |Q3|Unknown|Unknown|Part is not as specification|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000068912|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000064909|21/02/2011|priority 2 |Q3|TOTAL|NORTH SEA|Wrong size on the o-rings and pins|ATCO NOTE NOPT NOCO|Wrong size on o-rings  in BOM|Design |Material Master Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100050383|13/05/2016|priority 3 |Q3|Unknown|Unknown|Company decide to not upgrade el.boards|NOPT NOTE ATCO NOCO|CAM & IO board not last recommended rev.|Change/Deviation Request |Conversion approval|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|P7000016420|12/12/2011|priority 1 |Q3|Unknown|Unknown|Leitura do PT Não Conforme|NOTE NOCO NOPT ATCO|Mau funcionamento PT|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Other external causes |Customer Error/responsibility
ZF|100035014|12/08/2015|priority 2 |Q3|Unknown|Unknown|Ormen Lange Leaking Penetrator SEM B|ATCO NOTE NOCO|Leakage through optical penetrator|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Equipment Malfunction
ZE|P6000068912|22/10/2013|priority 2 |Q3|Unknown|Unknown|loose screws on outercan|ATCO NOCO NOTE|Operator forgot to torque all bolts.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Capture Mistake
ZF|P7000024900|07/06/2012|priority 1 |Q3|SHELL|Unknown|SEM Internal Pressure at Hyperbaric Test|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Marlim SCM 06|NOPT NOCO NOTI ATCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|P6000037365|16/04/2009|priority 3 |Q3|PETROBRAS|GOM|HP COV / SCHEMATIC  ISSUE|ATCO NOCO NOTE NOPT|HP COV / SCHEMATIC  ISSUE|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Design Error
ZD|P6000068770|10/12/2014|priority 2 |Q2|Unknown|Unknown|Damage on ROV Fishtail protection|NOTE ATCO NOPT NOCO|Damage on ROV Fishtail protection|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000039672|19/01/2016|priority Unknown|Q3|Unknown|Unknown|Plug For Filter With Swarf - PN 7103556|NOPT NOTE NOCO ATCO|Unknown|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Final Inspection Error
ZF|P7000039672|15/01/2014|priority 1 |Q3|Unknown|Unknown|ARRANHÕES NA BASE PLATE|NOPT NOTE NOCO ATCO|Unknown|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Damage during transport
ZF|100035013|20/09/2005|priority 3 |Q3|SHELL|Unknown|PLUS AND MINUS IS SWITCHED ON DHI|NOTE NOCO NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000024191|08/05/2012|priority 1 |Q3|Unknown|Unknown|Prob na montagem das capas de PTs|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|100016901|02/10/2013|priority 3 |Q2|Unknown|Unknown|Incorrect coating (B)|NOCO NOTE ATCO|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Coating Defect
ZF|P6000055605|27/12/2010|priority 1 |Q3|SHELL|GOM|CPU600 improving startup on long umbilic|ATCO NOPT NOTE NOCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000079433|07/02/2012|priority 3 |Q3|CONOCOPHILLIPS|Unknown|tubing batch number on zpp list is wrong|NOPT NOCO NOTE|Traceability list error  warehouse.|Documentation |Incorrect Certificates / Records|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Materials/Stores related |Operator Error
ZB|7104670|24/02/2012|priority 1 |Q1|STATOIL|NORTH SEA|GC 204 AMV PT failure (Statoil Heidrun)|NOTE NOPT NOCO ATCO|Customer Error/responsibility|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100046387|06/11/2015|priority 3 |Q3|Unknown|Unknown|CITV and MPFM test in FAT|ATCO NOPT NOCO NOTE|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000068902|23/01/2012|priority 3 |Q3|Unknown|Unknown|wiring error outer can|NOTE NOPT NOCO ATCO|Wiring error.Operator error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 11|NOTE NOCO NOPT ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000001843|20/04/2011|priority 1 |Q3|Unknown|Unknown|Revestimento|ATCO NOTE NOPT NOCO|Revestimento danificado|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000001621|09/06/2011|priority 1 |Q3|Unknown|Unknown|Tube suporte não monta|NOPT ATCO NOTE NOCO|Usinagem FMC|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Machine Shop Personnel |Operator error
ZF|P7000016420|24/02/2011|priority 1 |Q3|Unknown|Unknown|Tubo de vácuo|NOTE ATCO NOPT NOCO|Unknown|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000001621|10/12/2010|priority 1 |Q3|Unknown|Unknown|Vazamento de silicone durante estocagem|NOTE NOCO NOPT ATCO|Vazamento na bexiga durante estocagem|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000148934|30/11/2017|priority 1 |Q3|Unknown|Unknown|Wrong customer provided DHI card|NOPT ATCO NOCO NOTE|Wrong customer CPI DHI board installed.|Assembly |Other- Specify in comments|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Assembly |Other- Specify in comments
ZF|3805796|19/10/2010|priority 2 |Q3|CONOCOPHILLIPS|Unknown|Material not delivered to plant|NOPT ATCO NOCO NOTE|Taken into Aberdeen under wrong Project|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|P7000000897|31/01/2012|priority 1 |Q3|SHELL|Unknown|Transformador trocado|NOPT NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZD|100020278|21/07/2010|priority 1 |Q2|EXXONMOBIL|Unknown|INSPECT SCM - DAMAGED COUPLER RISK|ATCO NOTE NOCO|Vendor Liability|Damage |Damage during assembly|SS - Compl. & W.Over - XT - General|Hydraulic Connections/Fittings|Intercompany|FMC Kongsberg
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 16|NOTE ATCO NOCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|P6000105708|06/11/2014|priority 3 |Q2|Unknown|Unknown|no approved ats|NOPT NOCO ATCO NOTE|Vendor related: Documentation|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Documentation
ZF|P6000104111|17/12/2013|priority 3 |Q3|Unknown|Unknown|Hole pattern not fit|NOTE ATCO NOCO NOPT|Wrong part in SEM assembly BOM|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|FMC Engineering related |DWG Error
ZF|P6000042308|26/08/2009|priority 3 |Q3|Unknown|Unknown|PT18 broken.|NOCO ATCO NOTE NOPT|See ZF-QN 200139349|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Unknown
ZE|P6000064910|20/06/2014|priority 4 |Q3|TOTAL|Unknown|MCM mob - Values out of acceptance|ATCO NOCO NOTE|HFT procedure corrected|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000029747|24/02/2009|priority 3 |Q3|ENGIE|NORTH SEA|CPU600 startup problem|ATCO NOTE NOPT NOCO|Error to be confirmed in QN200124450|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|P6000079433|02/01/2012|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Not able to mount bolt.|NOCO NOPT NOTE|BOM not aligned with ASM instruction|Assembly Related |OBS-imension (tolerance)|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Engineering related |Engineering Error
ZF|P7000039672|24/11/2016|priority 2 |Q3|Unknown|Unknown|Contaminação / Contamitation|ATCO NOCO DLFL|||Damage |Damage from corrosion|Object Types to Eng Matl CLASS|scm_components|Vendor related |Packaging/Handling
ZB|100059647|06/03/2010|priority 2 |Q1|LLOG|GOM|UPT has erratic output|NOTE ATCO NOCO|UPT has erratic output|Test Related |OBS-Component Error|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Test |Damaged during testing
ZF|100030711|02/06/2004|priority 2 |Q3|STATOIL|Unknown|Kommunikasjonssvikt Oseberg J SCM 13|NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|3787102|16/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|Voided screws P/N 200017922|NOPT NOTE NOCO|voided 12.9 screw awaiting replacement|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P6000104116|21/11/2014|priority 3 |Q3|Unknown|Unknown|Compensator housing allignment fault|NOPT NOCO NOTE|Hole interface error  QN 200414769|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZD|P6000039844|02/09/2009|priority 2 |Q2|Unknown|Unknown|(SS) RUSTY ON TOP PLATE AREA|NOTE NOCO NOPT|Unknown|Coating/Plating |Painting Defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Packaging/Handling
ZE|P6000133916|30/01/2018|priority 2 |Q3|Unknown|Unknown|Total request to change oil in SCM|NOCO ATCO NOTE|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Causes for Improvement|Documentation
ZF|100052231|15/02/2011|priority 2 |Q3|CHEVRON|GOM|Missing Sign off|NOTE ATCO NOCO NOPT|Missing Sign Off|Change/Deviation Request |Process substitution request|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|Intercompany|FMC Houston
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOCO NOPT NOTE|ECN 7058839 - P7000017839|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000088604|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000141559|21/12/2016|priority 3 |Q3|Unknown|Unknown|Wrong wiring on SEM.|NOPT ATCO NOTE NOCO|PO not updated|Assembly |Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Documentation Requirement |Other- Specify in comments
ZF|100020562|30/11/2009|priority 3 |Q3|BP|GOM|Water in module after hyperbaric.|NOTE NOPT NOCO|Strainer  hose and fitting changed|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
Q3|7104670|12/09/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM DO-board failure|NOCO NOTI ATCO NOPT|DO150 card malfunction|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Root cause Engineering|Material fault
ZF|P6000088751|13/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000132097|31/03/2016|priority 3 |Q3|Unknown|Unknown|Too big leakage during SCM leakage test|ATCO NOCO NOTE|Design change|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Projects Related|Material error
ZF|100001156|10/11/2006|priority 4 |Q3|STATOIL|NORTH SEA|SCM not demobilised after operation|NOCO NOTE|Not demobilised after operation|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZD|100020562|14/03/2009|priority 3 |Q2|BP|GOM|MISSING CERTIFICATE OF COMPLIANCE|NOCO NOPT ATCO NOTE|MISSING C OF C|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|100035119|20/08/2004|priority 3 |Q3|PETRONAS|Unknown|WRONG ASSEMLING OF EL. RACK|NOPT NOCO ATCO NOTE|SEM A and SEM B swapped.|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Electrical|Wiring|FMC Assembly/Test related|Assembly/Test error
ZF|100035013|26/10/2009|priority 4 |Q3|SHELL|Unknown|Problems with powerline on SCM SEMB|NOTE ATCO NOCO|Problems with powerline on SCM SEMB|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZF|P6000105542|10/12/2014|priority 2 |Q3|Unknown|Unknown|SCM manifold block failure - SN 16|NOTE NOCO|Wrong welding pin defined for man. block|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|Class 1 ECN 6083510|NOPT NOCO ATCO NOTE|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000042968|25/04/2011|priority 1 |Q3|TOTAL|WEST AFRICA|PZF-SCM transport damage|ATCO NOPT NOTE NOCO|Unknown|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage during transport
ZF|7103233|08/11/2005|priority 1 |Q3|SUNCOR CPI|Unknown|12.9 bolts on LP and HP  adapterplates|NOPT NOTE NOCO|Unknown|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|100037966|07/02/2006|priority 1 |Q3|BP|Unknown|Wrong SEM adresses on control modules|NOCO ATCO NOPT NOTE|miscommunication within project|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte solonoider på ventiler.|ATCO NOPT NOCO NOTE|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
ZF|7101937|04/10/2004|priority 2 |Q3|LUFENG|Unknown|Magnetic Lee-plugs in manifoldblock.|NOTE NOCO ATCO NOPT|Lee-plugs with wrong material|Vendor related|Unknown|Subsea Control Module (SCM) Mech w/MB|Hydraulic manifolds|Vendor related|Material error
Q1|7103234|19/11/2002|priority 3 |Q1|Unknown|Unknown|SCM TN04I HP Ret.Flowm.unstable readings|ATCO NOTI NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
Q3|7105597|Unknown|priority 3 |Q3|Unknown|Unknown|FAT TPR-0011497 Sec 9.1.3.m)Acc. critera|NOPT NOCO NOTI ATCO|Accept criteria not fulfilled.|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|100026567|06/02/2004|priority 1 |Q3|STATOIL|NORTH SEA|SCM 2 Vigdis Ext. rubber pollut.  HPX1/2|ATCO NOPT NOCO NOTE|Unknown|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Miscellaneous Product Design errors
ZF|P6000076121|03/11/2011|priority 3 |Q3|CNOOC|Unknown|Chips found inside the HP-Config Plug|NOCO NOTE NOPT ATCO|Plugs not cleaned by supplier.|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|P6000088604|29/06/2015|priority 4 |Q3|Unknown|Unknown|(CDM) Missing API bucket for SCM|NOTE ATCO NOCO NOPT|Missing API bucket for SCM|FMC Other Defect |Part Lost|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100035013|11/11/2009|priority 4 |Q1|SHELL|Unknown|SUBSEA-Ormen Lange Claim 028 PTs SEMA|ATCO NOTE NOCO|To be investigated when SCM is retrieved|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |Cause not found
ZF|100055762|23/05/2008|priority 2 |Q3|STATOIL|NORTH SEA|Text height of SCM marking wrong size.|ATCO NOTE NOCO|Unknown|Marking |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
ZF|P7000016420|14/02/2011|priority 1 |Q3|Unknown|Unknown|PEÇA DANIFICADA|NOCO NOTE NOPT ATCO|ERRO NO  MANUSEIO|ERRO NO  MANUSEIO DA PEÇA|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Handling
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL ATCO NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
Q1|7101172|28/01/2003|priority 3 |Q1|STATOIL|NORTH SEA|DHPT GFA H-3H unstable in periodes|NOTI NOCO NOPT|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM well D-1H PT LP Supp. malfunction|ATCO NOTI NOPT NOCO|O-ring (PT)|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZF|P6000065886|15/12/2010|priority 2 |Q3|Unknown|Unknown|SEM bracket mangler M6 hull for klammer|NOCO NOPT NOTE|Design error on DWG|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|SEM Bracket|FMC Engineering related |DWG Error
ZB|100020562|25/10/2006|priority 2 |Q1|Unknown|Unknown|SEM A failed on SCM 06 on XT #4|NOTE NOPT NOCO|SEM A failed due to high voltage|Assembly/Test Related |Missed Operation-Assy/Test|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor audit related|Unknown
ZF|7104075|14/09/2005|priority 3 |Q3|SHELL|GOM|COV bolts on SCM PN 7104075|NOTE NOPT NOCO ATCO|BOM list error|Design |Material Master Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|7106268|22/02/2001|priority 3 |Q3|Unknown|Unknown|SCM M 04|NOTI ATCO NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - Luanda (Angola)|Goods Receipt|Initial/Direct product problem|Function
ZF|3794920|03/03/2004|priority 3 |Q3|Unknown|Unknown|Wrong piping to the flushing valve.|ATCO NOPT NOTE NOCO|Wrong piping on the SCM.|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Assembly/Test related|Assembly/Test error
Q2|100016711|20/02/2003|priority 3 |Q2|Unknown|Unknown|12 volt Power Supply found to be blown|NOTE ATCO NOPT NOCO|Unknown|103-Electrical|SEM Powersupply|Ext. loc. - KOS Houston|Work Shop|Root cause Vendor|Material/Component error
ZF|7102643|21/11/2003|priority 3 |Q3|STATOIL|NORTH SEA|SCM 40 ÅSG. L3H SEMA AI/SIO malfunction|NOPT NOTE NOCO ATCO|Vacuum plug not mounted.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|One atmosphere canisters|FMC Assembly/Test related|Assembly/Test error
ZF|P6000121393|13/04/2018|priority 3 |Q3|Unknown|Unknown|RIT: SCM SEM A/B Voltage Out of Range|NOTE ATCO NOCO|SCM SEM A/B Voltage Out of Range|Design |DBI Error|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Engineering related |Specification error
ZF|P7000039672|09/12/2013|priority 1 |Q3|Unknown|Unknown|Welding is not in accordance with drawin|NOPT NOCO NOTE ATCO|119863 -Bandak Notodden AS|Welding related |Lack of Weld|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZD|100020278|05/09/2013|priority 3 |Q2|Unknown|Unknown|Incorrect coating|NOTE ATCO NOCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Operator Error
Q3|7103233|11/01/2000|priority 3 |Q3|Unknown|Unknown|SCM 02P  CIDV 2 does not function|ATCO NOCO NOPT NOTI|Valve contaminated  ref. QN 200004305|102-Hydraulic|Chemical Control Valves|Ext. Loc. - St.Johns (Canada)|Goods Receipt|Initial/Direct product problem|Function
ZF|100037229|10/10/2005|priority 1 |Q3|PETROBRAS|Unknown|Flange and EC blind plug collide.|NOCO NOTE NOPT ATCO|Which part is out of tolerance is unknow|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|7105130|20/03/2003|priority Unknown|Q3|Unknown|Unknown|Pig detector failure on SCM|NOTE ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|Vendor|Root cause Assembly/Test|Workshop-Assembly/Test error
Q1|7105130|18/01/2000|priority Unknown|Q1|Unknown|Unknown|SCM M 02|NOPT NOTI ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|P6000080343|03/04/2013|priority 3 |Q1|Unknown|Unknown|Jubilee Claim SCM 02|NOTE ATCO NOCO|"Possible ""dirty"" hydraulic fluid"|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZD|P6000088751|06/03/2013|priority 1 |Q2|Unknown|Unknown|GWF SCM #3 CPU600 ERRORS|NOCO ATCO NOPT NOTE|SCM #3 CPU600 ERRORS|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Damaged during installation
ZD|P6000077632|30/04/2015|priority 3 |Q2|Unknown|Unknown|Missing Lifting Data Plate|NOPT NOTE NOCO ATCO|Missing Lifting Data Plate|Procurement |Incomplete Kit Of Parts|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100051269|10/09/2008|priority 4 |Q1|STATOIL|NORTH SEA|SEM not working|NOTE ATCO NOCO NOPT|Internal failure in the SEM A|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P6000068912|29/09/2011|priority 2 |Q3|Unknown|Unknown|Missing batch-management on 200017100|NOCO NOTE|Wrong ECN class used.|Design |DBI Error|Common/Misc - Fasteners - Metric|Screw|FMC Engineering related |DBI error
ZF|7104033|24/03/2014|priority 3 |Q3|Unknown|Unknown|Update GA DWG for various project SCM.|NOTE NOCO|Missing information regarding marking|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
Q3|7104670|02/08/2001|priority 2 |Q3|Unknown|Unknown|USE OF HFT PROCEDURE FOR GFS II FOR HNF|NOPT NOCO ATCO NOTI|HNF HTF PROCEDURE UNDER REVISION|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Test Procedure error
ZB|100020278|24/10/2006|priority 1 |Q1|Unknown|Unknown|SCM Silicone Check Valve did not check|ATCO NOTE NOCO|Unknown|Assembly/Test Related |Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes |No Non-Compliance
ZF|P6000109194|29/04/2014|priority 3 |Q3|Unknown|Unknown|LP supply flowmeter not working properly|NOCO NOPT NOTE ATCO|Not reading below 719ml/min|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|100046112|25/08/2005|priority 3 |Q3|WOODSIDE|Unknown|PROBLEM WITH UPDATE FROM RS485|NOTE NOPT NOCO|Software improvement|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000105542|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000093501|12/12/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|100017305|15/08/2001|priority 3 |Q3|Unknown|Unknown|Request to change SCM EC configuration|ATCO NOPT NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZC|7104670|10/08/2004|priority 4 |Q2|Unknown|Unknown|Unknown|ATCO NOTE NOCO|Wrong paint spec|Vendor related|Unknown|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|Vendor related|Fabrication error
Q3|7103233|Unknown|priority 2 |Q3|Unknown|Unknown|Feil i config file for flowmeter.|NOCO NOTI NOPT ATCO|Unknown|Product defects for dept. 1640|1644 Software|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Function
ZF|100016901|02/02/2004|priority 3 |Q3|BP|Unknown|PT failure|NOPT NOCO NOTE|Unknown error. It may be a PT error.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Operation/maintenance related |Expected wear and tear
ZF|P7000020444|20/05/2011|priority 1 |Q3|Unknown|Unknown|Furação desalinhada|ATCO NOCO NOTE NOPT|Bracket não monta|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Specification not followed
Q3|7103233|Unknown|priority 2 |Q3|Unknown|Unknown|AMV did not close during ESD Level 0|NOTI NOPT ATCO NOCO|SCM was busy operating chokes|103-Electrical|Modems/Communications|Defect locations - onshore|KOS Kbg. SCM-EFAT|Initial/Direct product problem|Function
ZF|3794920|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZB|100031223|17/11/2004|priority 3 |Q1|STATOIL|NORTH SEA|SCM 1 GF Diacs DH SEMA instability|NOCO NOTE NOPT|Variations within normal specifications|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|Other SCM sensors|Other external causes|Customer Error/responsibility
ZF|100030542|20/04/2004|priority 2 |Q3|Unknown|Unknown|Press. changes can dislodge Rubber Shim|ATCO NOCO NOPT NOTE|Design error|Assembly / Test related |Cleanliness|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Miscellaneous Product Design errors
ZF|100046112|20/12/2005|priority 3 |Q3|Unknown|Unknown|Damage on treads on Check Valve w/cap|NOTE NOCO NOPT ATCO|Threads damaged during testing.|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100035014|30/03/2012|priority 2 |Q3|Unknown|Unknown|MCM ROV Bucket out of tolerance|NOPT NOTE ATCO NOCO|Follow up in ZD QN:200257477|Machining Related |OBS-Position Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZD|P6000123495|09/09/2016|priority 2 |Q2|Unknown|Unknown|Transportation Damage & Missing ATS|NOTE ATCO NOCO|Unknown|Damage |Damage during transport|Object Types to Eng Matl CLASS|scm_mkIIE|Paintshop Related|Paint defect
ZB|100038200|01/02/2008|priority 2 |Q1|"BHP BILLITON PETROLEUM AMERICAS| INHOUSTON STOCKING SCM MK II (15K)"|Unknown|EC1 Alignment Key|ATCO NOTE NOCO|EC1 Alignment Key|Damage |Damage during testing|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |Unknown
ZF|P6000088604|16/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000029772|24/04/2009|priority 3 |Q3|ENGIE|NORTH SEA|External handling of SCM|ATCO NOCO NOTE NOPT|Operator Error|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000016420|18/11/2011|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 12|NOCO NOPT ATCO NOTE|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|7101401|13/06/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Failure Hose House assembly|NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Service Related:|Improper job preparation
ZF|100031223|06/05/2010|priority 3 |Q3|Unknown|Unknown|Error in drawing.|NOTE NOCO|Update of DWG  see QN200163243|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|7103233|20/10/2010|priority 2 |Q3|SUNCOR|Unknown|SCM returned to FMCK on MMT|ATCO NOCO NOPT NOTE|Goods Receiving Inspection error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P6000028371|23/10/2008|priority 1 |Q3|SHELL|GOM|Manifoldblock missing in iBASElist|NOCO ATCO NOTE|error during transition from hand ibase|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Machine Shop Personnel |Lack of Training
ZF|P1000018406|13/04/2012|priority 3 |Q3|BP|Unknown|Hydraulic supply hose rupture|NOCO NOTE ATCO|Hydraulic supply hose rupture|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q3|7106268|28/08/2003|priority 1 |Q3|TOTAL|Unknown|Substantial loss of presure on LP A andB|NOPT NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104075|Unknown|priority 3 |Q3|Unknown|Unknown|Feil i FAT procedure TPR-0011190 rev 4|ATCO NOPT NOTI NOCO|Feil unner saving av dokumenter|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
Q3|3794920|21/08/2001|priority 3 |Q3|Unknown|Unknown|Ventil som lekker ?|NOPT NOCO ATCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100016901|18/12/2003|priority 3 |Q3|BP|GOM|PT failure|NOPT NOTE NOCO|Unknown error. It may be a PT error.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Operation/maintenance related |Expected wear and tear
Q3|7103479|04/02/2002|priority 2 |Q3|Unknown|Unknown|FAT results are out of accept criteria|NOTI NOCO ATCO NOPT|Errors in test procedure|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
ZB|7104670|23/07/2018|priority 3 |Q1|Unknown|Unknown|CIDV1 was stuck in close position|NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 12 ÅsgA P1-H PT SIV malfunction|NOPT NOTI NOCO ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|P6000029747|18/11/2008|priority 2 |Q3|ENGIE|NORTH SEA|DSL communication loss too high|NOTE NOCO NOPT|Error outside the SCM (in Topside Eq.)|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Unknown
ZB|P6000064911|10/06/2016|priority 3 |Q1|Unknown|Unknown|Defect Not. 09 - SRMs|NOCO NOTE|cause unknown - no liabiliy for FMC|Electrical |Performance|FKS Quality system issues|Product Realization|Electrical |Other- Specify in comments
ZB|100048038|27/04/2009|priority 4 |Q1|AGBAMI|Unknown|Leak out SCM Relief Valve on AGB 20|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|X-mas Tree|Other XT|FMC Test |Unknown
Q2|7106268|Unknown|priority 3 |Q2|Unknown|Unknown|SCM I 01|NOPT NOTE NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
Q3|7104670|30/07/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  interface not sending 24v supply.|NOPT NOCO ATCO NOTI|No fault found at FMCKS|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZF|100048038|18/05/2006|priority 4 |Q3|CHEVRON|WEST AFRICA|Incorrect marking on Top plate|ATCO NOCO NOPT NOTE|Unknown|Design |Do Not Use|FKS Quality system issues|Quality Management System|FMC Assy |Missing Operation
Q3|7104670|16/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|WOCS  failure in software comm. with SCM|ATCO NOPT NOTI NOCO|SOFTWARE ADRESSING FAILURE TO SEM-B 520|Troubleshooting FMC Kongsberg|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Damages
ZE|P6000100953|01/10/2013|priority 3 |Q3|Unknown|Unknown|Errors in procedure TST60090648|NOCO NOTE NOPT|Procedure corrected  ref. ECN number|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000084906|18/01/2012|priority 3 |Q3|Unknown|Unknown|Not complete SW Rel3|ATCO NOTE NOPT NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|150/615 SW|FMC Engineering related |Engineering Error
Q1|7102643|20/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 40 ÅsgB Y-3H PT LP supply unstable|NOTI NOPT NOCO ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
ZF|P6000068902|26/09/2011|priority 3 |Q3|Unknown|Unknown|Wiring error|NOTE NOCO NOPT ATCO|Human error  during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100058509|19/01/2010|priority 3 |Q3|LLOG|GOM|Missing LP & HP vent to sea caps|NOCO NOTE NOPT ATCO|Missing LP & HP vent to sea caps|FMC Other Defect |Part Lost|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZF|100020562|08/07/2010|priority 2 |Q3|BP|GOM|Shipped without QA approval.|NOPT NOCO NOTE ATCO|Book not signed off on correctly.|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000123495|10/06/2015|priority 3 |Q3|Unknown|Unknown|Missing support ring & O-ring|NOCO NOPT ATCO NOTE|Missing support ring & o-ring on PT|Procurement |Incomplete Kit Of Parts|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Specification not followed
ZE|P6000074156|28/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM)Prellude- to blank out the ESRS|NOPT ATCO NOCO NOTE|Prellude- to blank out the ESRS|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P7000024900|13/09/2013|priority 1 |Q3|Unknown|Unknown|SCRATH ON BASE PLATE SCM BC-10 (44)|NOTE NOCO NOPT ATCO|Item not traceable|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000105542|26/06/2013|priority 3 |Q3|Unknown|Unknown|Too short screw for the trafo bracket|NOCO NOPT NOTE|Screws length is OK for use.|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |QN Cancelled
ZF|100052231|03/10/2006|priority 1 |Q3|CHEVRON|GOM|AI150 Modification of SoftWare|NOTE NOPT NOCO ATCO|New release of software on AI150-board|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
Q3|100017305|04/12/2002|priority Unknown|Q3|Unknown|Unknown|Lost communication on SEM A|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104670|06/03/2000|priority 3 |Q3|Unknown|Unknown|TEST SCM PASSER IKKE.|NOCO ATCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7102643|01/12/2003|priority 3 |Q3|STATOIL|NORTH SEA|SCM 15 ÅSGA L-4H SEM A Comm. problems|NOTE NOPT NOCO|Failed power supplies.|Vendor related|Unknown|Subsea Control Module (SCM) Electrical|Modem PCBs|Vendor audit related|Unknown
ZF|100018531|04/05/2011|priority 1 |Q3|Unknown|Unknown|DHI 108 card damaged.|ATCO NOCO NOTE NOPT|Wrong wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Test |Operator Error
ZE|P6000100953|24/05/2017|priority 2 |Q3|Unknown|Unknown|Lack of FNCR and SN Creation|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000088751|17/06/2016|priority 3 |Q3|Unknown|Unknown|Wiring Error.|NOCO ATCO NOTE|Error might be caused by situation ongoi|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Lack of training
ZF|100037428|29/11/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Configuaration file is wrong.|NOTE NOPT ATCO NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Engineering related |Engineering Error
ZF|P6000107981|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000068902|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 02|NOCO ATCO NOTE NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000122574|28/10/2015|priority 3 |Q3|Unknown|Unknown|too small diam inside filter|ATCO NOCO NOPT NOTE|Filter changed out.|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Material error
Q3|7105597|Unknown|priority 2 |Q3|Unknown|Unknown|Penetration of sea water in SCM|NOCO ATCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|03/07/2014|priority 1 |Q3|Unknown|Unknown|Parafusos da DCV danificados|NOTE NOCO NOPT ATCO|Unknown|Assembly Related |OBS-Interface issue|Common/Misc - Fasteners - Metric|Bolt|FMC Assy |Operator Error
ZF|P7000001843|22/12/2011|priority 1 |Q3|Unknown|Unknown|Flow meters|NOCO ATCO NOTE NOPT|Equipamento retornou do campo|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |Damage from Wear and Tear
Q3|7104670|24/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM 08 did not read press/temp.|NOCO NOPT NOTI ATCO|SIO card upgrade required|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZF|P7000000897|26/07/2012|priority 1 |Q3|Unknown|Unknown|PT não conforme.|ATCO NOCO NOPT NOTE|Missing the metal ring|Assembly Related |OBS-Interface issue|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Missing Parts
Q3|3794920|05/11/1999|priority 3 |Q3|Unknown|Unknown|SCM installation  lost sensor readings|NOTI ATCO NOPT NOCO|ROV pin connector damaged offshore|202-Electrical/Sensor equipment|Electrical Penetrators|Defect locations - offshore/field|Sleipner/Loke|Initial/Direct product problem|Function
Q1|7102969|01/10/2002|priority 3 |Q1|Unknown|Unknown|Broken bolts|NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Initial/Direct product problem|Material
ZE|100020278|02/05/2011|priority 1 |Q3|Unknown|Unknown|Serrated Washer Verification|NOTE NOPT NOCO|Improvement of BOM on repeat review|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Outer Can|Causes for Improvement|Documentation
ZF|P6000076121|09/09/2011|priority 3 |Q3|CNOOC|Unknown|Leakage from O-ring HP flowmeter|NOCO NOTE NOPT|O-ring damaged during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -Instrumentation|SCM Flowmeter|FMC Assy |Operator Error
ZF|P7000000897|01/06/2012|priority 1 |Q3|Unknown|Unknown|Change over com desvios|ATCO NOTE NOPT NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000068912|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100030542|23/02/2004|priority 2 |Q3|BAOBAB|Unknown|Silicone check valve is blinded.|ATCO NOPT NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000103208|07/05/2014|priority 3 |Q3|Unknown|Unknown|HP Flowmeter didnt show any value|NOPT NOTE ATCO NOCO|Particle caused wrong FM reading|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|NOTE NOPT ATCO NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|7104670|Unknown|priority 4 |Q3|Unknown|Unknown|Bytte av poppet i koplere. SCM 01|ATCO NOCO NOPT NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZE|100036232|15/11/2017|priority 3 |Q3|Unknown|Unknown|(LL) WO Shell Pierce OH29 SCM#T11 Pri4|OSTS OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100050383|05/11/2007|priority 1 |Q1|STATOIL|NORTH SEA|Tordis SCM-01  HTEM module B|ATCO NOCO NOTE|Unstable operational part|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P6000100953|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000064909|21/11/2011|priority 3 |Q3|Unknown|Unknown|Wiring failure|NOTE NOCO NOPT|Wiring fault. Human error.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000068912|01/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|7103233|11/05/2007|priority 2 |Q3|Unknown|Unknown|Unknown|NOCO NOPT NOTE|See SN 300162481|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZF|100017278|10/11/2005|priority 3 |Q3|STATOIL|NORTH SEA|Silicon leakage after refurbishment|NOCO ATCO NOPT NOTE|Damage caused by assembly|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P6000123495|21/10/2015|priority 3 |Q3|Unknown|Unknown|LP Flowmeter and LPr Flowmeter switchet.|NOTE NOCO|Failure not discovered during inhouse|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Test |Operator Error
ZF|P6000079984|22/11/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100001156|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|Failure on AI card on SEM A  well M-4H|NOTE NOPT ATCO NOCO|AI card might be of batch with failure|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Do Not Use
Q1|7101401|22/05/2002|priority 2 |Q1|PETROBRAS|Unknown|SCM 4 Marlim HP Leak CVHP Supp. to Ret.|NOPT NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Leakage
Q3|7101172|03/10/2000|priority 2 |Q3|Unknown|Unknown|More flow to open SCSSV than normal|ATCO NOCO NOTI NOPT|Leaking SCSSV (down hole safety valve)|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Leakage
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte solonoider på ventiler|ATCO NOCO NOTI NOPT|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
Q3|7104075|24/08/2001|priority 3 |Q3|Unknown|Unknown|Shipping Damage to Shell SCM #25|NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Goods Receipt|Root cause Other|Logistics-Packing/Shipping Damage
ZF|7104033|17/03/2014|priority 2 |Q3|Unknown|Unknown|Reduction of mobilization scope|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100020278|16/01/2007|priority 3 |Q3|EXXONMOBIL|Unknown|MISSING FILL VALVE PLUG AND SEAL|NOCO NOTE NOPT ATCO|Missing Fill Valve Plug and Seal|Procurement |Vendor did not complete required work|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|Unknown|Too high cracing pressure on check valve|NOPT NOTE NOCO|Cracing pressure not verified on SCM|Assembly / Test related |Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Procedure error
ZF|P6000069056|29/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|CVHP 58 & 54 Positions swapped|NOPT NOCO NOTE|Assembled on wrong position on M.block|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000068902|04/05/2017|priority 4 |Q3|Unknown|Unknown|CLOV SCM sensor schematic wrong|NOTE ATCO NOCO|Error in drawing||Documentation Requirement |Part Description / Drawing|Object Types to Eng Matl CLASS|scm_mkIII|Documentation Requirement |FMC Engineering Error
ZF|P7000001621|20/05/2010|priority 1 |Q3|Unknown|Unknown|Desvio de planicidade|NOTE NOPT NOCO ATCO|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Other causes/damage |Cause not found
ZD|100034440|10/09/2005|priority 3 |Q2|Unknown|Unknown|Missing Documentation|NOCO NOPT ATCO NOTE|Documents errors|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
Q3|7102969|21/06/2000|priority 2 |Q3|Unknown|Unknown|Small amount of water in module|NOTI NOPT ATCO NOCO|Leak from center rod sealing|101-Mechanical|Locking Mechanism|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Leakage
ZF|7104075|29/09/2005|priority 3 |Q3|MARUBENI|GOM|missing check valve assembly|NOTE ATCO NOCO NOPT|Missing check valve assembly|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZB|P6000055605|02/12/2013|priority 3 |Q1|Unknown|Unknown|Bonga Claim 001 SCM 315|NOCO NOPT NOTE|MRM failure|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|Other el/opt components|Vendor related |Equipment Malfunction
Q3|7100320|24/10/2001|priority 2 |Q3|PETROBRAS|Unknown|SCM Hercules malfunc.SEM A/B power inlet|ATCO NOCO NOTE NOPT|Not yet known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Function
ZF|7105130|31/05/2012|priority 1 |Q3|TOTAL|Unknown|To high pressure on valves during hyper|NOTE NOCO ATCO NOPT|357bar on DCVs during hyperbaric test|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|100034440|30/11/2010|priority 2 |Q3|HOUSTON STOCKING MK IV|Unknown|Class 1 ECN 6083510|ATCO NOPT NOTE NOCO|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000016420|19/09/2011|priority 1 |Q3|Unknown|Unknown|Revestimento do pino guia não conforme|NOTE ATCO NOCO NOPT|REVESTIMENTO|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZF|7104075|25/01/2008|priority 2 |Q3|Unknown|Unknown|Damaged EC Connector|NOPT NOTE NOCO ATCO|Unknown|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZB|100049392|05/01/2017|priority 2 |Q1|Unknown|Unknown|Leakage on HC supply F2-LP|NOPT NOCO ATCO NOTE|Cause wiil be determined during repair|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000088626|27/01/2015|priority 3 |Q3|Unknown|Unknown|CVLP23 is Not operating wrong wiring doc|NOTE ATCO NOCO|Specification updated  ref ECN 6176801|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000068902|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000105542|06/08/2014|priority 2 |Q3|Unknown|Unknown|SCM router cards damaged|ATCO NOCO NOTE|Error engineering  followed up 200394337|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100017278|27/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|SCM exposed with too high pressure|NOTE NOCO NOPT ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZE|7102969|25/04/2005|priority 3 |Q3|MOBIL EG|Unknown|(Change to ZF)|ATCO NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000122626|09/07/2018|priority 3 |Q3|Unknown|Unknown|SCM  Updates to Agbami 615 Test procedur|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100015314|13/04/2015|priority 3 |Q3|Unknown|Unknown|Incorrect SESI described in procedures|NOCO NOTE ATCO|Error in documentation.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZB|100038200|27/03/2009|priority 3 |Q1|SHELL|Unknown|Loss of Communication SEM-B WELL-3|NOTE ATCO NOPT NOCO|Cause not found at this time|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Other causes/damage |Cause not found
ZE|100035013|27/03/2015|priority 1 |Q3|SHELL|Unknown|SCM silicone oil leakage|NOCO ATCO NOTE|Silicone bladder assembly prd updated|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Compensator|Causes for Improvement|Documentation
ZB|P7000002082|02/05/2017|priority 3 |Q1|PETROBRAS|Unknown|Mecanismo de travamento inoperante|NOTE ATCO NOCO|Causa não encontrada|FMC Other Defect |Functional|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Other causes/damage |Cause not found
ZF|100037965|23/11/2017|priority 1 |Q3|Unknown|Unknown|Deviation Request: SCM Retrieval with LU|NOTE NOPT ATCO NOCO|ICP calls for retrieval w/ MRT+LU and cl|Change/Deviation Request |Process substitution request|SS - Intervention - Running Tool|SCM Running Tool|Documentation Requirement |Other- Specify in comments
ZF|P7000039672|13/03/2014|priority 1 |Q3|Unknown|Unknown|Trafo sem marcação de alinhamento|NOTE NOPT NOCO ATCO|FMC KONGSBERG SUBSEA AS|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|100018531|21/12/2016|priority 3 |Q3|SHELL|Unknown|MMR - Water on Silicone Sample|ATCO NOPT NOTE NOCO|O-ring damaged during assembly|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Assy |Damaged during assembly
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 20|NOCO NOPT NOTE ATCO|Investigate Coupler Rotation-BPAT SCM 20|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZD|P6000055605|20/01/2012|priority 3 |Q2|SHELL|GOM|ISSUE WITH SCM CONVERSION|NOPT NOCO ATCO NOTE|Issue with SCM Conversion|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOPT NOTE NOCO|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZE|P6000098616|30/01/2014|priority 3 |Q3|Unknown|Unknown|clear description of test in ASY60044250|NOTE NOCO|Already proposed in a existing QN|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000116360|09/12/2013|priority 3 |Q3|Unknown|Unknown|Deviations from TR1233 ver 5 for SCM|NOPT NOCO ATCO NOTE|QN based on comlience with TR requir.|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7105130|06/02/2001|priority 3 |Q3|Unknown|Unknown|SCM M General|NOCO NOPT NOTI ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - Luanda (Angola)|Goods Receipt|Initial/Direct product problem|Operation & Maintenance Manual (OMM)
ZF|P7000039672|23/06/2015|priority 1 |Q3|Unknown|Unknown|Conjunto de conector c/ mangueira trocad|ATCO NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Material error
ZF|100055762|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOTE NOPT ATCO NOCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZD|P6000084242|08/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PARTNUMBER|ATCO NOTE NOCO NOPT|INCORRECT PARTNUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q3|7105128|09/02/2000|priority 1 |Q3|Unknown|Unknown|SCM P 04|NOPT NOCO ATCO NOTI|Unknown|101-Mechanical|Locking Mechanism|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZE|P6000043714|21/09/2009|priority 2 |Q3|PETROBRAS|GOM|Communication between Houston and Norway|NOPT NOTE NOCO|Unknown|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|Causes for Improvement|Process/Procedure Ineffective
ZE|P6000093498|13/08/2014|priority 3 |Q3|Unknown|Unknown|Water in Silicone sample|NOTE ATCO NOCO|See attached RCA.|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Capture Mistake
ZE|7103233|22/10/2014|priority 2 |Q3|Unknown|Unknown|EC`s in baseplate not grounded.|NOTE ATCO NOCO|Operator did not follow DWG/BOM|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|100055762|28/01/2008|priority 3 |Q3|STATOIL|NORTH SEA|missing batch numbers|NOCO NOTE NOPT|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100020562|03/08/2004|priority 3 |Q3|Unknown|Unknown|SCM Software timing error|ATCO NOPT NOCO NOTE|Software error|Assembly / Test related |Function|Software  FKS provided|SEM|FMC Other causes|Miscellaneous
ZF|P6000062990|21/01/2015|priority 3 |Q3|Unknown|Unknown|Wrong DHI board|ATCO NOCO NOTE NOPT|DHI114 delivered instead of DHI117|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Wrong Part Delivered
ZF|P6000042969|15/06/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Error during pressure test.|NOPT ATCO NOTE NOCO|Human mistake not discovered before FI|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000069056|26/10/2012|priority 3 |Q3|Unknown|Unknown|MRMS MAC ADRESSE|NOCO NOPT NOTE|Untrained Opr. / unclear procedure|Documentation |Procedure / Process Error|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Other causes/damage |No Non-Compliance
ZF|100048038|05/06/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|Spare connection to be verified|NOPT NOTE ATCO NOCO|Bad connection in spare connector|Assembly/Test Related |Function|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Manufacturing Engineer Erorr
ZF|7103233|23/10/2006|priority 2 |Q3|Unknown|Unknown|TNO SCM 11P HOST A SEM B malfunction|NOCO NOTE|SEM B electronic card failure|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P7000039672|28/12/2015|priority 1 |Q3|Unknown|Unknown|Unknown|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZB|7102969|29/10/2009|priority 1 |Q1|MOBIL EG|Unknown|09-MEGI-033 Unable to establish comms|NOCO ATCO NOTE|09-MEGI-033 Unable to establish comms|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Penetrator|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000067533|14/02/2011|priority 3 |Q3|Unknown|Unknown|Wrong in the Inhouse testing Procedure|ATCO NOCO NOTE|Wrong in the Inhouse testing Procedure|Documentation |Procedure / Process Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Procedure error
ZF|P6000098616|27/06/2013|priority 2 |Q3|Unknown|Unknown|HS CAN bus grounding error on CPU card|NOTE NOPT NOCO ATCO|ISO GND missed in wiring specification|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P6000068924|31/01/2012|priority 3 |Q3|Unknown|Unknown|Inhouse procedure is not corrected|NOCO NOTE ATCO NOPT|Inhouse procedure wrong.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000001621|18/10/2011|priority 2 |Q3|Unknown|Unknown|Problemas dimensionais.|NOCO ATCO NOPT NOTE|causa ainda não definida|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000028371|16/09/2008|priority 3 |Q3|SHELL|GOM|Wrong SW on SEM during Inhouse|NOTE NOPT NOCO|Unknown|FMC Other Defect |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|P7000039672|28/10/2014|priority 1 |Q3|Unknown|Unknown|Falha no teste DHI Transparent Link|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Test |Missed operation
ZF|P7000001621|28/03/2013|priority 1 |Q3|Unknown|Unknown|Outer can amassada|NOTE ATCO NOPT NOCO|Unknown|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000024191|14/06/2012|priority 1 |Q3|Unknown|Unknown|SEM 600 Test Box não conforme.|ATCO NOPT NOTE NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100037966|25/04/2006|priority 3 |Q3|BP|Unknown|Problem Assemble blindplug  returnfilter|NOCO ATCO NOPT NOTE|error with hole F61|Machining Related |Inside Diameter Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|100036936|26/01/2005|priority 1 |Q3|STATOIL|NORTH SEA|Protection Ring does not fit SCM|ATCO NOTE NOPT NOCO|Slot not updated after change of N2 port|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|100017305|04/03/2002|priority 3 |Q3|Unknown|Unknown|First SCMs with standard DigiTron 12-pin|NOTI NOCO NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000066700|13/09/2011|priority 1 |Q3|HOUSTON STOCKING V2|Unknown|Missing HC in SCM OKONO|ATCO NOTE NOCO|Human error  process not maintained|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100037229|16/01/2008|priority 3 |Q3|Unknown|Unknown|Brazil / Unauthorized Valve Movement|ATCO NOPT NOTE NOCO|Defective RAM chip|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000068912|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000088604|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000068912|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update SCM PSM - Luanda Workshop|NOTE NOCO|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000016420|16/06/2011|priority 1 |Q3|Unknown|Unknown|Conector J4 da placa TIF da eletronica B|NOCO ATCO NOTE NOPT|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Improper handling
ZE|100048038|05/02/2018|priority 4 |Q3|Unknown|Unknown|SCM  Update to documentation|ATCO NOTE NOCO|Update of DOC and BOM.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000043714|26/10/2010|priority 3 |Q3|PETROBRAS|GOM|Missing Engineering Sign offs|NOTE ATCO NOCO|No non compliance|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000008275|07/05/2010|priority 1 |Q3|Unknown|Unknown|Dog com interferência com o canal do nut|NOPT NOTE ATCO NOCO|Porcas com dimensões erradas|Assembly Related |OBS-imension (tolerance)|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Assy |Manufacturing Engineer Erorr
ZF|100036936|29/12/2004|priority 2 |Q3|Unknown|Unknown|Marking of hydraulic lines|NOCO NOTE NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100020562|14/02/2006|priority 2 |Q3|BP|GOM|FAILURE TO OPPERATE TO PRD REQUIREMENTS|ATCO NOCO NOPT NOTE|CHECK VALVE FAILS TO OPERATE CORRECTLY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|Unknown|SCM Change Hydraulic Fluid|ATCO NOCO NOTE|SCM to be reflushed|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q3|7102643|20/09/2000|priority 3 |Q3|Unknown|Unknown|SCM hydraulic leak  line 17  well I-4H|NOTI ATCO NOPT NOCO|Check valvefitting damaged when handling|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Viking Poseidon|Initial/Direct product problem|Leakage
Q3|7103905|08/11/2001|priority 3 |Q3|AGIP|Unknown|The SCM is leaking silicon|NOTI NOCO ATCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100046112|11/08/2005|priority 3 |Q3|WOODSIDE|Unknown|Problem with RS485 sensors probably SW|NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000074156|23/01/2013|priority 2 |Q3|Unknown|Unknown|DHI 205 acceptance criteria wrong.|NOTE NOPT NOCO ATCO|Typing error in TST60070027&TST60070028|Documentation |Procedure / Process Error|FKS Quality system issues|Measuring  Analysis & Improvement|FMC Engineering related |Procedure error
ZF|P7000039672|19/01/2016|priority 1 |Q3|Unknown|Unknown|RESÍDUO ENCONTRADO NO PLUG FOR FILTER|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
Q3|7103233|Unknown|priority 3 |Q3|Unknown|Unknown|Error message from SCM.|ATCO NOPT NOTI NOCO|Unknown|Product defects for dept. 1640|1644 Software|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Function
ZF|100046387|11/06/2007|priority 1 |Q3|STATOIL|NORTH SEA|No communication with SEM A or SEM B.|NOCO ATCO NOTE NOPT|Update SW|Design |R & D Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM S/N 11 G-2H GFA PT HP Funct. malfunc|ATCO NOTI NOCO NOPT|Top of PT is off|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZF|P6000055605|23/03/2012|priority 3 |Q3|SHELL|Unknown|Unstable comm. with SEM B in FAT|ATCO NOPT NOTE NOCO|LNCS630 error  follow-up by QN200263019|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZF|P7000024191|23/10/2012|priority 2 |Q3|Unknown|Unknown|Coupler de supply fora da revisão atual|ATCO NOTE NOPT NOCO|ECN não implementada|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100030542|03/12/2007|priority 1 |Q3|BAOBAB ADD. XT P11/P12|Unknown|Pressure reading was not the correct val|NOTE ATCO NOPT NOCO|Wron limits in test procedure|Documentation |Incorrect user documentation (customer)|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Engineering related |Procedure error
ZF|P6000039844|21/01/2011|priority 1 |Q3|Unknown|Unknown|(SS)SCM - Product Improvement|NOTE NOCO NOPT|Marginal design on silicone compensator|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 13|NOPT NOTE NOCO ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|7102643|31/08/2000|priority 3 |Q3|Unknown|Unknown|No comms with WEPS sensors  well Y2-H|NOTI ATCO NOCO NOPT|FMCKS: No fault found on SEM B.|103-Electrical|SEM El.Rack|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q3|100017305|06/02/2003|priority 3 |Q3|STATOIL|Unknown|Ruptured compensator bladder|ATCO NOCO NOPT NOTI|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Leakage
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Oppgrader Marlim 05-ALFA til 05-GAMA|ATCO NOCO NOPT NOTI|Unknown|101-Mechanical|Mechanical Components|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|100046112|25/08/2005|priority 3 |Q3|WOODSIDE|Unknown|PROBLEM WITH UPDATE FROM RS485|NOTE NOCO NOPT ATCO|Software improvement  see ECN 6006365|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100048038|11/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|SCM SILICONE CONTAMINATION|ATCO NOTE NOPT NOCO|SILICON CONTAMINATION|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Packaging & Storage
ZF|100037427|13/06/2013|priority 3 |Q3|Unknown|Unknown|Valves operated with too high pressure|ATCO NOPT NOTE NOCO|DCVs operated with too high pressure.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100037966|26/03/2014|priority 1 |Q3|Unknown|Unknown|P11 SCM -Communications Fault Offshore|ATCO NOTE NOCO|Possible Wear and Tear|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|Other el/opt components|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000126219|25/10/2016|priority 3 |Q3|Unknown|Unknown|Wiring issue on LNCS|NOCO NOPT NOTE|Wiring issue on LNCS|Assembly |Assembled Incorrectly|Object Types to Eng Matl CLASS|scm_mkIIE|Electrical |Mis-wired internally
ZF|100058509|22/02/2010|priority 3 |Q3|LLOG|GOM|Choke Quick Move Command Issue|NOCO NOTE NOPT ATCO|Choke Quick Move Command Issue|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZF|100030665|07/02/2006|priority 3 |Q3|SHELL|Unknown|PRESSURE IS INCREASING ON HP RTN SYSTEM|NOTE NOCO ATCO NOPT|leakage within acceptance criteria|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P6000103208|03/12/2013|priority 3 |Q3|Unknown|Unknown|Wring fault for sensors on EC9 10 and 11|NOPT NOTE NOCO ATCO|Wiring not acc. to specification|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000000897|20/10/2016|priority 3 |Q3|SHELL|Unknown|MMR - Outer Can Closure Failure|NOPT ATCO NOCO NOTE|lack of documentation for process|Assembly |Misalignment / Interface Error|Subsea Control Module (SCM) Mech w/MB|Outer can|Documentation Requirement |Process step missing
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|08/10/2013|priority 1 |Q3|Unknown|Unknown|ECN  6147855 - PN  P7000039672|NOPT ATCO NOTE NOCO|ECN|Design |DBI Error|SS - Controls -Hydraulic Distribution|Other hydraulic components|FMC Engineering related |ECN Change
ZF|P7000039672|06/05/2015|priority 1 |Q3|Unknown|Unknown|COUPLER SEM O-RING|NOPT ATCO NOCO NOTE|Unknown|FMC Other Defect |Part Lost|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Missing Parts
ZF|P6000042969|18/06/2009|priority 1 |Q3|Unknown|Unknown|CV9 to be tested|NOTE NOPT ATCO NOCO| Procedure error.|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|100005667|06/02/2001|priority 3 |Q3|Unknown|Unknown|HXT bore test leak trough SCM ret.to sea|ATCO NOTI NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Leakage
ZF|P6000104116|01/10/2014|priority 3 |Q3|Unknown|Unknown|Damaged sealing surface|NOTE NOCO ATCO NOPT|Surface damage during modification work|Machining Related |OBS-Surface Finish Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZB|P6000088751|15/04/2016|priority 3 |Q1|Unknown|Unknown|WEL  SCM  Documentation Error|NOCO NOPT ATCO NOTE|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P6000069056|20/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|Wiring on EC4  mislabeled-Outercan test|NOCO NOPT NOTE|Opr.failure during wiring & marking|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZD|100049000|22/07/2010|priority 3 |Q2|BP|GOM|Missing vent cap on BPAT SCM 23|NOCO ATCO NOTE|Missing vent cap on BPAT SCM 23|FMC Other Defect |Part Lost|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZE|P7000024900|05/04/2013|priority 2 |Q3|Unknown|Unknown|RCA|ATCO NOTE NOCO|Conectores de topo em posições erradas|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Process/Procedure Not Being Followed
Q3|7103233|08/02/2002|priority 2 |Q3|OVERALL PROJECT ROLL-UP|Unknown|Locking mech pin broke/SCM refurbishment|NOCO NOTI ATCO NOPT|Suspect damaged during offshore handling|101-Mechanical|Locking Mechanism|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
Q3|100016110|01/05/2001|priority Unknown|Q3|Unknown|Unknown|SCM communication Address|NOCO NOPT NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100025661|27/01/2010|priority 3 |Q3|SHELL|GOM|Shell SCM 81 CPU warranty work|NOPT NOTE NOCO ATCO|Shell SCM 81 CPU warranty work|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000008275|27/05/2012|priority 1 |Q3|Unknown|Unknown|Gráfico do Labview|ATCO NOTE NOCO NOPT|Falha no Labview|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000063531|11/04/2017|priority 3 |Q3|Unknown|Unknown|Not able to perform E&M-Probe test.|NOPT NOCO NOTE ATCO|CPI test equipment not available|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIII|Test |Other- Specify in comments
ZF|3812476|21/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|Defect rectifier bridge and diode  SEM B|NOCO ATCO NOTE NOPT|FMC Test: Damaged during testing|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM MAN/SIV 04|NOCO NOPT NOTE ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000104112|09/12/2015|priority 3 |Q3|Unknown|Unknown|water found in silicone sample|ATCO NOPT NOTE NOCO|Follow-up QN 200476490|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P6000083428|18/09/2012|priority 3 |Q3|Unknown|Unknown|GA dwg error|NOCO ATCO NOTE|GA dwg missmatch (nameplate hi WP error)|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|7101401|26/09/2013|priority 1 |Q3|PETROBRAS|Unknown|MMR - SEM A not comm. Hyperaric Test|ATCO NOPT NOTE NOCO|EC connector not mouting correctly|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100020562|09/03/2004|priority 4 |Q3|BP|GOM|SCM accidentally dropped with X-mas Tree|ATCO NOPT NOCO NOTE|Handling error|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Other external causes|Customer Error/responsibility
ZF|P7000016420|20/12/2011|priority 1 |Q3|Unknown|Unknown|Arranhão na Bracket.|NOCO ATCO NOTE NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Packaging/Handling
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 05|NOPT ATCO NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000063632|20/12/2010|priority 2 |Q3|Unknown|Unknown|gas leak test not acording to LWI|NOTE NOPT ATCO NOCO|Procedure error.Engineering|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100020562|05/01/2009|priority 1 |Q3|Unknown|Unknown|All Tests In Procedure Not Completed|NOCO ATCO NOTE NOPT|All Tests In Procedure Not Completed|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P7000016420|28/02/2011|priority 1 |Q3|Unknown|Unknown|Revestimento não conforme|NOTE ATCO NOPT NOCO|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Cause not found
ZF|P6000068924|31/08/2011|priority 3 |Q3|Unknown|Unknown|Wiring feil på EC2|NOTE NOPT NOCO|Incorrect wiring by operator|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
Q3|7102969|30/09/2002|priority Unknown|Q3|MOBIL EG|Unknown|Anode problem on SCM|NOTI NOPT NOCO|The use of anodes on SCM's (Michael May)|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Initial/Direct product problem|Material
ZF|7104670|04/07/2003|priority 3 |Q3|STATOIL|NORTH SEA|Electronic failure|NOTE NOPT ATCO NOCO|1)wrong connection  2)loose bolts|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|ROV el. connectors|FMC Assembly/Test related|Assembly/Test error
Q3|7105128|05/06/2000|priority Unknown|Q3|Unknown|Unknown|SCM P 03|ATCO NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000029772|31/05/2013|priority 4 |Q3|Unknown|Unknown|SRM software not up to date|ATCO NOPT NOCO ORAS NOTE|Specification error|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Engineering related |Specification error
ZF|P6000058949|07/12/2010|priority 3 |Q3|Unknown|Unknown|Error on GA  and name plate|NOPT ATCO NOTE NOCO|Human error.|Marking |Marking content error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Materials/Stores related |Operator Error
Q3|7105128|05/06/2000|priority Unknown|Q3|Unknown|Unknown|SCM P 02|NOTI NOPT NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100035118|17/08/2004|priority 2 |Q3|WOODSIDE|Unknown| DIFFERENCE OF COUNTS IS TO HIGH|NOPT NOTE NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|100017305|02/10/2002|priority Unknown|Q3|Unknown|Unknown|Connectors demates before guiding|ATCO NOCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|P6000088614|02/06/2015|priority 3 |Q3|Unknown|Unknown|Error in in flow on line 5 and 24|NOTE NOCO NOPT ATCO|Suface finish outside SPC|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|100017278|29/09/2010|priority 3 |Q3|STATOIL|NORTH SEA|Loose lee plug on blind plate.|NOPT ATCO NOCO NOTE|Not enough friction in lee plug|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|SCM Communication problems offshore|NOPT ATCO NOCO NOTI|timing problem on modem boards|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Shell Alliance GOM|Initial/Direct product problem|Function
ZF|P7000001621|11/05/2015|priority 1 |Q3|PETROBRAS|Unknown|MMR - Base Plate|NOTE ATCO NOPT NOCO|Unknown|Machining Related |OBS-Angle error|Subsea Control Module (SCM) Mech w/MB|SCM mounting base|FMC Machine Shop Personnel |Operator error
ZF|100017997|12/09/2012|priority 2 |Q3|Unknown|Unknown|BOM error for SN 05 and  SN 06|NOCO NOTE NOPT ATCO|BOM not correct for repeat orders on TH.|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000074855|07/12/2011|priority 3 |Q3|Unknown|Unknown|Lacking XML-file for prosject|NOPT NOTE NOCO ATCO|Missing XML-file|Documentation |Procedure / Process Error|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Test |Missed operation
ZF|P6000088751|07/06/2013|priority 2 |Q3|Unknown|Unknown|Contamination of HP lines in SCM|NOCO NOTE NOPT ATCO|Contamination of HP lines in SCM|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZE|P6000088614|04/10/2017|priority 3 |Q3|ENI|Unknown|Errors in HFT60078748 for SD2 SCM|NOTE NOCO ATCO|Error in HFT procedure|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Documentation Requirement |Error in document / spec
ZF|P6000105542|08/06/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|P6000064909|20/06/2011|priority 3 |Q3|TOTAL|Unknown|No output voltage from SPCTU|NOCO ATCO NOTE NOPT|Damaged during testing|Test Related |OBS-Component Error|SS - Controls - Test and Transportation|Subsea Power & Communication Test Unit (|FMC Test |Damaged during testing
ZE|7100320|03/09/2003|priority 2 |Q3|PETROBRAS|Unknown|SCM 09 HERC. Sensor mismatch A/B|NOCO NOPT NOTE|Unknown|Unknown|Unknown|Subsea Control Module (SCM) Mech w/MB|One atmosphere canisters|Accepted -&|Do Not Use
ZF|100030542|31/03/2006|priority 2 |Q3|Unknown|Unknown|SCM damaged in transit|NOCO NOPT NOTE|Procedure not followed|Design |Do Not Use|SS - Intervention - Running Tool|SCM Running Tool|Vendor audit related|Unknown
Q3|7102643|17/10/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
Q3|7100320|02/12/1999|priority Unknown|Q3|Unknown|Unknown|Oppgrader Hercules 13-GAMA til 13-OMEGA|NOTI NOCO ATCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7105129|17/02/2003|priority Unknown|Q1|Unknown|Unknown|SITE QUERY: RESISTANCE 470 OHM MISSING|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|3812476|04/02/2000|priority 2 |Q3|Unknown|Unknown|Well D2T2H  SCM SCSSV PT 'over range'|NOCO NOPT ATCO NOTI|SCM PT defective/SCM recovered|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZF|100035118|06/01/2005|priority 1 |Q3|Unknown|Unknown|Unknown|NOPT ATCO NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000080733|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOCO NOTE NOPT|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
Q1|3801623|Unknown|priority 1 |Q1|Unknown|Unknown|Compensator and accumulator are loose|NOCO NOPT ATCO NOTI|Missing screws/poor control at KOS|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Material
ZF|100030542|27/09/2005|priority 3 |Q3|CNR|Unknown|Failure on PT11|NOPT NOTE NOCO|SN 300096773 - PT11 failed in SCM 07|Damage |Unknown|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Vendor audit related|Unknown
ZF|100035400|19/01/2006|priority 3 |Q3|HESS|GOM|HFT DOC NOT IN ACCORDANCE WITH DAT FILE|NOPT NOTE NOCO ATCO|HFT DOCUMENT ERROR|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|7105128|10/09/2015|priority Unknown|Q3|Unknown|Unknown|Lack of spares - Concession by Client|NOPT NOCO ATCO NOTE|Unknown|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Other mechanical components|QA/QS/QI Related|Documentation error
Q3|7103233|14/03/2001|priority 4 |Q3|Unknown|Unknown|Suspect SCM HP rtn was over pressured|NOCO ATCO NOPT NOTI|FMC test procedure error has damaged SCM|102-Hydraulic|Hydraulic Control Valves|Ext. Loc. - St.Johns (Canada)|Work Shop|Root cause Engineering|Test Procedure error
Q3|7100320|Unknown|priority Unknown|Q3|Unknown|Unknown|Skifte solenoider ventiler sn. 12|NOPT ATCO NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100056261|23/06/2010|priority 2 |Q3|MURPHY|WEST AFRICA|Missing sign offs|ATCO NOTE NOCO NOPT|Unknown|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZB|100020562|26/01/2007|priority 3 |Q1|BP|GOM|Low pressure value observed on the AMV.|NOCO NOTE NOPT ATCO|Internal PT's failed|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Component error
ZF|100051991|12/09/2007|priority 3 |Q3|Unknown|Unknown|Fell from the truck|NOTE NOPT NOCO ATCO|Handling|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor audit related|Unknown
ZF|P6000103208|26/03/2014|priority 4 |Q3|Unknown|Unknown|Hydraulic leakage LP return flow meter|ATCO NOPT NOTE NOCO|O-ring not in position during FMassembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100020562|11/05/2010|priority 3 |Q1|BP|GOM|Over torqued to the skid|NOCO ATCO NOTE|Over torqued to the skid|Assembly Related |OBS-Interface issue|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Assy |Operator Error
ZF|100037966|14/03/2005|priority 3 |Q3|BP|Unknown|DHI IS WRONG WIRED|NOTE NOPT NOCO ATCO|Unknown|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q1|7102969|27/09/2002|priority 1 |Q1|MOBIL EG|Unknown|SCM Comms failure  Well shut down|NOCO ATCO NOTE NOPT|Electr. failure within the SEM(S.Tatum)|103-Electrical|Modems/Communications|Defect locations - offshore/field|Pride Africa|Initial/Direct product problem|Function
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL ATCO NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|7104075|29/07/2005|priority 3 |Q3|MARUBENI|GOM|DAMAGE TO EC7 CONNECTOR|NOTE NOCO ATCO NOPT|Unknown cause of damage|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOPT NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000064909|30/05/2011|priority 3 |Q3|TOTAL|NORTH SEA|Leakage during hyperbaric|NOCO ATCO NOTE NOPT|Hose clamp was not tightened|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZB|P6000042970|07/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|SCM MAN/SIV #2|NOCO ATCO NOTE NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100025661|06/10/2005|priority 3 |Q3|SHELL|GOM|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|NOTE ATCO NOPT NOCO|Choke close command error|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q1|7104075|Unknown|priority 2 |Q1|Unknown|Unknown|Skade i pakningsflade i ytterkande|NOPT NOTI ATCO NOCO|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|Customer goods receipt|Initial/Direct product problem|Leakage
ZF|100049000|19/07/2011|priority 3 |Q3|BP|Unknown|Dial caliper coupler measurements|ATCO NOTE NOCO NOPT|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100037428|13/09/2005|priority 1 |Q3|TOTAL|WEST AFRICA|Return compensator retest SCM P03|NOTE ATCO NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|PT adapter plate is loose|NOPT NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Refurbishment - Bytting av PT'er.|NOTE NOCO ATCO NOPT|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
Q3|7104670|26/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|Tilbakekalt modul (SIO-kort)|NOPT NOCO NOTI ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q3|7104670|24/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM 10 did not read press/temp.|NOPT NOTI ATCO NOCO|SIO card upgrade required|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZB|100050519|16/10/2009|priority 2 |Q1|Unknown|Unknown|Silicon leak on SCM Sn 07|NOCO NOTE ATCO|Leaking SCM in box received in Congo|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage during transport
Q3|7104670|14/08/2001|priority Unknown|Q3|Unknown|Unknown|USE OF HFT PROCEDURE FOR GFS II FOR HNF|NOCO NOPT ATCO NOTI|HNF HTF TEST PROCEDURE UNDER REVISION|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Montasje|Root cause Engineering|Test Procedure error
Q3|7103233|Unknown|priority 3 |Q3|Unknown|Unknown|LP and HP Return Pressure Compensation|NOPT NOCO ATCO NOTI|Review of requirements|102-Hydraulic|Accumulators|Unknown|Unknown|Unknown|Unknown
ZF|P6000069056|17/11/2016|priority 4 |Q3|Unknown|Unknown|Silicone leakage on EC 7|ATCO NOTE NOCO|Silicone leakage on EC 7|FMC Other Defect |Physical|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|100016901|04/04/2005|priority 3 |Q3|Unknown|Unknown|RIT failed|NOPT ATCO NOCO NOTE|RIT failed|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZB|P6000042969|31/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 16|NOCO ATCO NOPT NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100052134|17/12/2007|priority 2 |Q1|PETROBRAS|GOM|Communication Failure|ATCO NOPT NOTE NOCO|Random failure on electronics component|Damage |Wear & Tear|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor audit related|Unknown
ZF|P6000093498|24/03/2015|priority 3 |Q3|Unknown|Unknown|Leakage in EC|NOPT NOCO NOTE ATCO|Unknown|Test Related |OBS-Leakage (gas)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q3|100018600|24/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|The centre rod is slow to operate|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100050519|02/04/2013|priority 2 |Q3|TOTAL|Unknown|Findings on GR Inspection in Congo|NOCO ATCO NOTE|MF-0000020212 updated with extra step|Damage |Damage from corrosion|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZD|P6000080343|23/08/2012|priority 3 |Q2|Unknown|Unknown|CRATE DAMAGED|NOTE NOPT ATCO NOCO|CRATE DAMAGED|Damage |Damage during transport|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|Vendor related |Damage during transport
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytting av solenoider på ventiler.|ATCO NOTE NOPT NOCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZD|100025661|29/08/2007|priority 3 |Q2|SHELL|GOM|SCM Failed HFT|NOPT NOCO ATCO NOTE|SCM Failed HFT|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
ZF|100037966|31/08/2005|priority 3 |Q3|BP|Unknown|HIGH PRESSURE DISCOVERED ON RTN. LINE|NOTE NOCO ATCO NOPT|Return hose not properly connected|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100067526|11/01/2016|priority 2 |Q3|Unknown|Unknown|Not able to perform DHI118 on MOB|NOPT ATCO NOCO NOTE|Customer don't have available test equip|Obsolescence Issue:&|Not Available|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|Other external causes |Customer Error/responsibility
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000074156|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000068902|26/04/2015|priority 2 |Q3|Unknown|Unknown|Update SCM HFT|NOCO NOTE|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000024191|17/09/2012|priority 2 |Q3|Unknown|Unknown|SRT Global 7 can bus and Serial Line S2|NOTE NOPT NOCO ATCO|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100056443|17/08/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|SCM fault on B-communication.|NOTE NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - WOCS|Other WOCS Products|FMC Test |Missed operation
Q3|7102643|20/03/2001|priority 3 |Q3|Unknown|Unknown|SCM CDIV not closed evaluate OMM|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Operation & Maintenance Manual (OMM)
ZF|100037428|24/11/2006|priority 1 |Q3|TOTAL|WEST AFRICA|DH gauge card failure|NOCO NOPT NOTE|Activity transferred to SN300117780|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |QN Cancelled
ZB|100048038|03/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|SCM #14 PT16 SEM A & B FAILURE|NOTE NOCO|SCM #14 PT16 SEM A & B FAILURE|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes/damage |Cause not found
ZF|100026567|28/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|TUBE TO HP ACCUMULATOR IS BENT WRONG|ATCO NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000024191|17/07/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|NOCO ATCO NOPT NOTE|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7103233|06/03/2000|priority Unknown|Q3|Unknown|Unknown|Low temp. qual.test results not approved|NOPT NOCO ATCO NOTI|Tests out of limits and some not done|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q3|7105131|01/02/2001|priority 3 |Q3|Unknown|Unknown|SCM M/MFM General|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - Luanda (Angola)|Goods Receipt|Initial/Direct product problem|Documentation
ZF|100050519|12/06/2006|priority 3 |Q3|MOHO BILONDO|Unknown|Nitrogen in silicon after hyperbaric.|NOTE ATCO NOPT NOCO|no specification of required thread|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100025661|12/07/2006|priority 3 |Q3|SHELL|GOM|HFT STEP CAN NOT BE EXECUTED|NOPT NOCO ATCO NOTE|Cable Length Simulator Availability|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000055605|27/12/2010|priority 2 |Q3|SHELL|GOM|CPU600 improving startup on long umbilic|NOCO ATCO NOTE|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|100048038|21/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|Problems with valve operation in tank.|NOTE NOPT ATCO NOCO|Test Tank had loose fitting|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|7104075|28/06/2000|priority 3 |Q3|Unknown|Unknown|Refurbishment of Shell SCM 07|NOTI NOPT NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOTE NOCO NOPT|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZF|P7000039672|12/01/2016|priority 1 |Q3|Unknown|Unknown|Dano na SEM Bracket|NOPT NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|SEM Bracket|FMC Assy |Operator Error
ZF|P6000080733|09/01/2013|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100017997|19/01/2007|priority 2 |Q1|Unknown|Unknown|IWOCS POD did not register any flow|NOCO NOTE NOPT|ETU eror with SEM B SCM|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Hydraulic flow meters|FMC Manufacturing related |Programme Error
ZB|100037965|03/05/2013|priority 2 |Q1|Unknown|Unknown|BP SCM w/ wrong sofware version|NOCO NOPT NOTE ATCO|Sofware version not updated.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000039672|19/01/2015|priority 1 |Q3|Unknown|Unknown|Parafuso da válvula danificado|NOTE NOCO NOPT ATCO|Unknown|Assembly Related |OBS-Interface issue|Common/Misc - Fasteners - Metric|Screw|Vendor related |Final Inspection Error
ZF|P6000104115|23/05/2014|priority 3 |Q3|Unknown|Unknown|Wrong drilling of center hole of trafo|NOCO NOTE NOPT ATCO|Follow-up against vendor by QN 200384061|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Clarification
ZF|P7000001621|29/02/2012|priority 1 |Q3|Unknown|Unknown|Tampa hose house não casando.|NOPT NOTE ATCO NOCO|Equipamento retornou do campo|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Damage from Wear and Tear
Q3|100018532|18/12/2002|priority 3 |Q3|SHELL|Unknown|Ruptured compensator bladder|NOTI NOPT ATCO NOCO|Inner tube not designed for SCM 200|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|Customer goods receipt|Root cause Engineering|Other Product Design error
ZF|100048038|12/05/2006|priority 3 |Q3|CHEVRON|WEST AFRICA|Damaged treads on screw and nut|NOPT NOCO NOTE ATCO|Damaged treads on the screw and nut|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
Q1|100018531|04/10/2002|priority 2 |Q1|SHELL|Unknown|SCM 3 Bijup.& Salema 12pin Tronic malf.|NOCO NOTI NOPT|Unknown|202-Electrical/Sensor equipment|Electrical Pin Connetors|Def. loc. - Testing (not int. SCM)|IT (Integration Test)|Root cause Vendor|Assembly/Fabrication/Test error
ZF|3794920|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|Leakage on hydra. coupler on SSP SCM 61|NOCO ATCO NOTE|Leakage from poppet|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic couplers|FMC Other causes|Miscellaneous
Q1|7105129|13/03/2002|priority 3 |Q1|TOTAL|Unknown|SCM 02 Girassol  SEM A malfunction|NOCO ATCO NOTI NOPT|lost auto update on SCM line A.|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Pride Africa|Initial/Direct product problem|Function
ZF|P6000068902|14/08/2013|priority 1 |Q3|Unknown|Unknown|protection caps missing from SCM|NOPT ATCO NOTE NOCO|PROTECTION CAPS NOT SUPPLIED|Procurement |Incomplete Kit Of Parts|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZD|100037427|26/03/2009|priority 1 |Q2|Unknown|Unknown|CERT ISSUE|NOCO ATCO NOTE|VL - Missing certs|Documentation |Missing Certificates / Records|SS - Compl. & W.Over - XT - General|Tree Assembly|Vendor related |Operator Error
ZF|100048038|22/11/2006|priority 1 |Q3|CHEVRON|WEST AFRICA|External leak from COVLP|NOTE ATCO NOPT NOCO|fittings not tight & displaced o-ring|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q1|7102643|20/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 48 ÅsgB J-3H no comm. SEM A|ATCO NOPT NOCO NOTI|Unknown|103-Electrical|Modems/Communications|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
ZF|P6000101955|25/02/2015|priority 4 |Q3|Unknown|Unknown|transportation notice unreadable|NOTE ATCO NOCO|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Handling
ZB|7104670|14/11/2011|priority 2 |Q1|STATOIL|NORTH SEA|Mobilisation maintenance not performed|NOTE ATCO NOPT NOCO|SCM not mob. acc. to requirements|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|100037965|11/03/2009|priority 1 |Q3|BP|Unknown|Loss communication on SEM B|NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000069056|05/10/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|NOCO ATCO NOTE NOPT|Lack of necessary test equipment.|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIII|Test |Other- Specify in comments
Q3|100018082|13/02/2002|priority Unknown|Q3|Unknown|Unknown|HYDR FLOW RESTRICTION IN QDV CIRCUIT|NOTI NOCO ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
Q3|3794920|16/11/1999|priority 3 |Q3|Unknown|Unknown|PT values change when wires are moved|NOTI NOCO ATCO NOPT|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000088751|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000043714|15/04/2011|priority 1 |Q3|PETROBRAS|GOM|Testing to recreate failure per FNCR|NOPT ATCO NOTE NOCO|Testing to address offshore failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000125394|09/06/2015|priority 3 |Q3|Unknown|Unknown|Missing support ring & O-ring|NOCO NOTE NOPT ATCO|Unknown|Procurement |Incomplete Kit Of Parts|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Specification not followed
ZF|100064910|04/08/2015|priority 3 |Q3|Unknown|Unknown|Better design to get easy closing  SCM|NOCO NOTE|Issue will be followed up in QN200456671|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|P6000028371|04/08/2015|priority 3 |Q2|Unknown|Unknown|Defect on EC port|ATCO NOCO NOTE|Unknown|Welding related |Lack of Weld|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
Q3|7103233|Unknown|priority 2 |Q3|Unknown|Unknown|SCM shows 'framing error' during EFAT|NOCO NOTI NOPT ATCO|Unknown|103-Electrical|Modems/Communications|Defect locations - onshore|KOS Kbg. SCM-EFAT|Initial/Direct product problem|Function
Q3|100016110|01/05/2001|priority Unknown|Q3|Unknown|Unknown|CVLP-5 was slow to open|NOPT NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100018600|25/03/2011|priority 2 |Q3|PETROBRAS|Unknown|Falha na Placa HCTB SEM B|ATCO NOCO NOPT NOTE|MMR Activities|FMC Other Defect |Part Lost|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Maintenance
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte solonoider på ventiler.|NOCO NOPT ATCO NOTI|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
ZF|P6000105542|10/12/2014|priority 2 |Q3|Unknown|Unknown|SCM manifold block failure - SN19|NOCO NOTE NOPT|Wrong welding pin defined for man. block|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZD|P6000088751|22/02/2013|priority 1 |Q2|Unknown|Unknown|GWF SCM #3 DHI COMMUNICATION INSTABLE|NOCO NOPT NOTE ATCO|COMMUNICATION INSTABLE|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Damaged during installation
ZF|P6000079433|24/01/2012|priority 3 |Q3|Unknown|Unknown|Leakage from blind plate|ATCO NOPT NOCO NOTE|O-ring damaged on blind plate|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Operator Error
ZF|P7000024900|16/10/2013|priority 1 |Q3|Unknown|Unknown|Scratch inside of the Outer Can|ATCO NOCO NOTE NOPT||101545 - KRISTIANSANDS SKRUEFABRIKK|101545 - KRISTIANSANDS SKRUEFABRIKK|Assembly Related |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Damaged during assembly
ZF|100049000|01/06/2010|priority 2 |Q3|BP|Unknown|Shipped w/o QA approval|ATCO NOTE NOCO NOPT|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZD|P6000068912|30/07/2013|priority 2 |Q2|Unknown|Unknown|Missing Valve Cap P/N:100014108 from SCM|NOPT ATCO NOCO NOTE|Missing Protection Cap|Marking |No Marking|SS - Controls -SCM Test Stand|Hydraulic Couplers|Intercompany|FMC Kongsberg
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOCO NOPT NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000024900|15/03/2012|priority 1 |Q3|Unknown|Unknown|no communication with MRMS and CPU|NOCO ATCO NOPT NOTE|Lab test box with problem.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZE|P6000068918|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update MCM PSM - Luanda Workshop|NOCO NOTE|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000024900|04/06/2013|priority 1 |Q3|Unknown|Unknown|DAMAGE ON THE THREAD|NOCO ATCO NOPT NOTE|115215 - TESS DRAMMEN AS  AVD. KONGSBERG|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Final Inspection Error
ZF|P7000039672|12/03/2014|priority 1 |Q3|Unknown|Unknown|PLUG FOR FILTER DANIFICADO.|NOPT ATCO NOCO NOTE|1242 HTS maskinteknikk as|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Final Inspection Error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOCO ATCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100030542|30/03/2006|priority 2 |Q3|Unknown|Unknown|FNCR RISED FOR CNR INTERNATIONAL|ATCO NOCO NOPT NOTE|See QN200038889|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P7000001843|19/04/2012|priority 1 |Q3|Unknown|Unknown|Flow meter c/ leitura incorreta|NOCO ATCO NOTE NOPT|Flow technology|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
Q3|7105128|28/03/2000|priority Unknown|Q3|Unknown|Unknown|SCM P 02|NOTI ATCO NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7105130|26/11/2006|priority 1 |Q3|TOTAL|Unknown|SCM outer can collapsed|ATCO NOCO NOPT NOTE|used SCM when recommended to replace OC|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOPT NOTE NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000068902|10/08/2011|priority 3 |Q3|Unknown|Unknown|Protector Cover for PT and valves|NOTE NOPT NOCO|PT covers full of plastic burrs|Machining Related |OBS-Burr/Chips|SS - Controls -SCM el/opt components|Other el/opt components|Vendor related |Specification not followed
ZF|P6000102554|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100020562|22/08/2009|priority 2 |Q1|BP|GOM|SEM A SIO board failure on Channel 0|NOPT NOCO ATCO NOTE|SEM A SIO board failure on Channel 0|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|I/O PCBs|Vendor related |Equipment Malfunction
ZF|100052701|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE|Unknown|FMC Other Defect |Functional|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Planning error
ZF|P6000105542|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|100017997|30/05/2002|priority 3 |Q3|Unknown|Unknown|M8x55 A4-80  bolts used on COV|NOPT NOCO ATCO NOTI|Module buildt before change of BOM|Quality System Issues|KOS Quality system issue|Defect locations - onshore (HES)|Kongsberg SCM-126A/B|Initial/Direct product problem|Material
ZB|100048038|14/02/2009|priority 3 |Q1|AGBAMI|Unknown|PT sensor for CIV-04 gives bad readings|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000000897|02/11/2012|priority 3 |Q3|Unknown|Unknown|Item não apresentado no Set Out|NOCO ATCO NOTE NOPT|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P6000068902|06/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|100017305|01/10/2001|priority 3 |Q3|Unknown|Unknown|AUX Clarification for SCM`s|NOPT ATCO NOTI NOCO|Incompatible requirements in specificati|103-Electrical|SEM Powersupply|Defect locations - onshore (HES)|Admin|Root cause Engineering|Design Specification error
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Refurbishment  Bytte av Trykktransdusere|NOCO NOPT NOTE ATCO|Unknown|103-Electrical|RCM Electronics|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|3812476|14/05/2010|priority 3 |Q3|Unknown|Unknown|Duplicate doc describing work process|ATCO NOTE NOCO|No failure QN created to STD helium test|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|100018820|26/08/2002|priority 3 |Q3|Unknown|Unknown|SCM`s ARE BUILT FOR 230V INSTED FOR 450V|NOPT ATCO NOCO NOTE|Design spec error - corrected|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Root cause Engineering|Other Product Design error
Q1|7104033|04/03/2003|priority 2 |Q1|STATOIL|NORTH SEA|SCM 06 Sygna N-2H poss. hyd lock 24/25|ATCO NOPT NOCO NOTE|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - offshore/field|Borgland Dolphin|Root cause Engineering|Other Product Design error
ZF|P6000104115|16/08/2014|priority 4 |Q3|Unknown|Unknown|Water inside the SRM|NOCO ATCO NOTE NOPT|O-ring on OC1 damaged follow-up200398887|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 31|NOTE NOPT ATCO NOCO|Investigate Coupler Rotation-BPAT SCM 31|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|NOTE NOCO|Wrong flowrestrictor used|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |DBI error
ZF|P7000024191|10/04/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #18 Can Bus & Serial Line|ATCO NOCO NOTE NOPT|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000079032|07/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|Drain holes for outercan not acc to dwg|NOCO NOTE|Outercan not produced acc to DWG|Machining Related |OBS-Slot Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000079433|02/02/2012|priority 2 |Q3|CONOCOPHILLIPS|Unknown|SCM S/N 01 PT's not working|NOCO NOTE ATCO NOPT|No failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000073687|14/06/2012|priority 3 |Q3|Unknown|Unknown|APT4 not working|NOCO NOPT ATCO NOTE|Pin 9 and 10 was switched on EC4|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
Q1|7101401|05/03/2002|priority Unknown|Q1|PETROBRAS|Unknown|Choke control valve malfunction|NOPT NOCO NOTI|Contamination in hyd system|Unknown|Unknown|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Cleanliness
Q3|100031193|16/04/2004|priority Unknown|Q3|PETROBRAS|Unknown|Wrong SEM adress on marking plate|NOTE NOCO ATCO NOPT|Plate not mounted on at the time of insp|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Goods Receipt|Root cause QA/QS|QA/QS Inspection error
Q3|7104033|10/05/2000|priority 3 |Q3|STATOIL|NORTH SEA|XT Annulus PTs  readings are fluctuating|ATCO NOTI NOCO NOPT|Suspect moisture is causing offset|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Statfjord C|Initial/Direct product problem|Function
ZF|100052231|11/12/2006|priority 2 |Q3|CHEVRON|GOM|Service order due to AI 150 issue|ATCO NOTE NOCO NOPT|improvement of DC/DC converter quality|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZF|P6000103208|21/03/2014|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|7103553|11/10/2017|priority 2 |Q3|SHELL|Unknown|Correct communication frequenzy  SCM M02|NOTE NOCO|Should have been ZE QN. ZE 200553194|Software |Program configuration|SS - Controls -Computer system software|150/615 SW|FMC Other causes/damage |QN Cancelled
ZF|100018600|16/02/2004|priority 3 |Q3|PETROBRAS|Unknown|FAIL WITH COMMUNICATION TO SEM A AND B|NOTE ATCO NOCO NOPT|Bad wiring in test equipment.|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|Modem PCBs|FMC Assembly/Test related|Miscellaneous
ZF|100052701|04/11/2009|priority 3 |Q3|STATOIL|NORTH SEA|Batch no. missing in iBASE|NOCO NOPT NOTE ATCO|Batch no missing on bolts in iBASE|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Specification error
ZF|100055762|02/05/2016|priority 3 |Q3|Unknown|Unknown|WGM simulator not available for MOB test|NOTE NOPT NOCO ATCO|CPI WGM simualtor not available|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Test |Missing Parts
ZF|100067526|28/11/2014|priority Unknown|Q3|Unknown|Unknown|DU600076575 - incorrect text EC3 and EC4|NOCO NOTE ATCO|DWG updated  ECN 6174744|Design |Drawing Error|SS - Controls -SCM el/opt components|El. Connector|FMC Engineering related |DWG Error
ZF|P6000069056|01/09/2011|priority 2 |Q3|Unknown|Unknown|MRM topside on SPCTU|NOTE NOCO ATCO NOPT|Failure outside SCM  (cable in SPCTU)|Test Related |OBS-Function|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Other causes/damage |QN Cancelled
ZF|100041493|19/12/2006|priority 4 |Q3|STATOIL|NORTH SEA|All return pipings were rusted off|ATCO NOCO NOPT NOTE|Wear and tear|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|100056443|16/03/2011|priority 2 |Q3|STATOIL|NORTH SEA|No respons from DH gauge at Troll O2 O23|NOCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Other causes/damage |Cause not found
ZF|7104075|02/08/2005|priority 3 |Q3|Unknown|Unknown|Shell SCM 10 has 2 bad PT's|NOPT NOTE NOCO ATCO|Shell SCM 10 has 2 bad PT's|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZD|100025661|13/02/2007|priority 2 |Q2|SHELL|GOM|TRANSMITTER GIVEN BAD READINGS|NOCO ATCO NOTE NOPT|BAD TRANSMITTER|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
Q3|7105597|Unknown|priority 2 |Q3|Unknown|Unknown|EFAT performed before Inhouse test|NOPT NOCO ATCO NOTI|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
ZF|P6000126219|15/08/2017|priority 3 |Q3|Unknown|Unknown|Faultfinding - Megging of EC 2 ethernet|ATCO NOTE NOPT NOCO|unwillingly IR tested wire 7 & 8|TEST |Function|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Test |Incorrect set up/testing
ZF|P7000024900|14/11/2013|priority 1 |Q3|Unknown|Unknown|SOLICITAÇÃO DE CONCESSÃO|ATCO NOPT NOCO NOTE|Unknown|Change/Deviation Request |Raw Material substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100035013|06/08/2008|priority 3 |Q3|SHELL|Unknown|missing earth on baseplate plug|NOPT NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|7104033|16/11/1999|priority 3 |Q3|Unknown|Unknown|SEM B sitt power supply ødelagt|ATCO NOPT NOCO NOTI|Unknown|103-Electrical|SEM El.Rack|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Damages
Q3|7103479|03/10/2001|priority Unknown|Q3|Unknown|Unknown|Comms. failure (SCM returned) + upgraded|ATCO NOCO NOTI NOPT|No Fault Found ref. REP-0012372|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Other|Customer-Customer error
ZB|7102969|21/03/2007|priority 3 |Q1|EXXONMOBIL|Unknown|HP sensor not corresponding with externa|NOTE NOCO|Closed as info only.|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes |QN Cancelled
Q3|7102643|20/03/2001|priority 3 |Q3|Unknown|Unknown|SCM PT incorr.feed back reg.valve status|NOPT ATCO NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|100027228|02/06/2003|priority 3 |Q3|STATOIL|NORTH SEA|MANGLET SIGN. PÅ FUNKSJONSLINJE|NOTE ATCO NOPT NOCO|Unknown|Service/maintenance related|Unknown|Software  FKS provided|ETU|FMC Engineering related|Procedure error
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrade Marlim SCM 03-ALFA to 03-GAMA|ATCO NOTI NOCO NOPT|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZB|7102643|12/02/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 221-Åsgard-SCM replacemen|NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZF|100020278|05/08/2005|priority 3 |Q3|EXXONMOBIL|Unknown|The El.Can screws are too short.|NOPT NOTE ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|3794920|09/11/1999|priority 3 |Q3|Unknown|Unknown|PT damaged during dis-assembly|NOPT ATCO NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100056443|22/10/2009|priority 2 |Q3|STATOIL|NORTH SEA|Sensor error|NOTE NOPT NOCO|Pressure sensor is within requirment|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P6000042968|09/12/2009|priority 3 |Q3|TOTAL|WEST AFRICA|deviation between tank and scm pressure|ATCO NOCO NOTE NOPT|Hose Glued not Silicone bladder nippel|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100018082|14/01/2013|priority 2 |Q3|STATOIL|NORTH SEA|FSM Test in FAT not performed|ATCO NOTE NOCO NOPT|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZD|100048038|11/03/2008|priority 3 |Q2|CHEVRON|WEST AFRICA|Unapproved Material Used|ATCO NOTE NOCO NOPT|Unapproved Material Used|Raw Material |OBS-Unapproved material subst|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|7105128|10/11/2003|priority Unknown|Q3|TOTAL|Unknown|Refurbish SCM|NOCO NOTE NOPT ATCO|Pending investigation|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|Unknown|Unknown
Q1|100006609|20/03/2003|priority 3 |Q1|PETROBRAS|Unknown|SCM 03 Ronc. slot 3/4 hyd.coupl. malfunc|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104670|Unknown|priority 1 |Q3|Unknown|Unknown|SCM problems w/ comm. to DH simulator|NOTI ATCO NOCO NOPT|Unknown|103-Electrical|DHI Interface|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZF|P6000088604|12/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No failure detected in extended testing|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100016711|06/01/2010|priority 2 |Q1|BP|GOM|SCM 32 Silicone Relief Check Valve|ATCO NOCO NOTE|Improper calibration|Damage |Damage during assembly|FKS Quality system issues|Quality Management System|FMC Assy |Operator Error
ZB|P6000083428|22/04/2015|priority 4 |Q1|Unknown|Unknown|Knarr Claim 009 PT Manifold SCM SUBSEA|NOTI NOPR OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000031350|18/11/2008|priority 1 |Q3|STATOIL|NORTH SEA|Bolts not torque-marked|ATCO NOTE NOCO|Unknown|Marking |No Marking|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q3|3801623|Unknown|priority 2 |Q3|Unknown|Unknown|"Feil målemotstand R4 / ""Flytte"" anode"|NOTI ATCO NOPT NOCO|Fleire feilforhold|103-Electrical|SEM El.Rack|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q3|7102643|17/10/2000|priority 4 |Q3|STATOIL|NORTH SEA|SCM upgrades after removal of outer can|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
Q3|100020278|30/01/2003|priority 3 |Q3|EXXONMOBIL|Unknown|EC`s were assembled wrong in outercan.|NOPT NOCO ATCO NOTI|SCM workshop assembly error|Misleading DWG|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Tank test|Root cause Assembly/Test|Other Product Design error
Q3|7103233|10/01/2000|priority 3 |Q3|Unknown|Unknown|Fresh water flowed through SCM HP return|ATCO NOCO NOPT NOTI|XT valve opened by error when testing|101-Mechanical|Hydraulic Manifold Block|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOPT NOCO ATCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000016420|06/10/2011|priority 1 |Q3|Unknown|Unknown|Return compensator|NOPT NOCO ATCO NOTE|cleanness - Quality Hidraulic power|Test Related |OBS-Cleanliness|SS - Controls - Hydraulic Products|Compensator|Vendor related |Specification not followed
ZF|P6000063531|27/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|CPU600 improving startup on long umbilic|NOTE ATCO NOCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000121268|01/12/2014|priority Unknown|Q3|Unknown|Unknown|Check valve missing O-ring|ATCO NOPT NOTE NOCO|O-ring not scope of supply|Design |Specification Error|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Engineering related |Engineering Error
ZF|100048038|06/09/2006|priority 1 |Q3|CHEVRON|WEST AFRICA|Problem with AI151 cards|NOPT ATCO NOCO NOTE|Bad workmanship|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P7000024191|25/10/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Pin of Extension Rod Smashed|NOCO NOPT NOTE ATCO|Handle of Lock Mech torqued|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Assy |Improper handling
ZF|P7000001621|04/04/2013|priority 1 |Q3|Unknown|Unknown|QA não convocado|NOTE NOCO NOPT ATCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100037428|16/08/2006|priority 3 |Q3|TOTAL|WEST AFRICA|Rosa SCM Nr.7 failure|NOCO NOPT NOTE ATCO|Weakness in Procedure   HFT-0000021176|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100020278|21/03/2011|priority 3 |Q3|EXXONMOBIL|Unknown|Re test SCM (RIT)|ATCO NOPT NOTE NOCO|SCM used to test SS18 and Tree4/7.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
Q3|100016901|15/01/2003|priority 3 |Q3|BP|GOM|EC's on top of SCM installed wrong|NOCO ATCO NOPT NOTI|Wrong DWG|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Work Shop|Root cause Engineering|Other Product Design error
ZB|P1000004979|17/01/2008|priority 2 |Q1|BP|Unknown|DH gauges fail to initialize|NOPT NOCO NOTE|Unknown|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|DHI PCBs|Vendor related |Equipment Malfunction
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000121958|30/12/2015|priority 4 |Q3|Unknown|Unknown|SCM Wiring Does Not Match Field Wiring|ATCO NOTE NOCO|SCM Wiring Does Not Match Field Wiring|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100048038|26/06/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|Damage to EC13 and procedure problems|NOTE NOCO ATCO NOPT|HFT Document Errors|Inspection of Test Stand Did not detect|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|7104075|04/12/2006|priority 3 |Q3|SHELL|GOM|Out Of Range Index Readings on ETU|ATCO NOPT NOCO NOTE|Index Readings Out Of Range On ETU|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P6000055605|04/11/2011|priority 3 |Q3|Unknown|Unknown|TST60053523 Software documents|ATCO NOCO NOTE NOPT|Procedure TST60053523 has been updated|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOTE NOPT ATCO NOCO|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100037427|09/11/2010|priority 2 |Q3|Unknown|Unknown|Wrong S/N on outercan|NOTE NOCO NOPT|Wrong S\N in ibase list|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZF|100048038|04/10/2006|priority 2 |Q3|AGBAMI|Unknown|AI 151 card has to be updated|NOPT NOCO NOTE ATCO|Problem with software AI 151 card|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |DWG Error
ZF|7104075|23/08/2005|priority 3 |Q3|SHELL|GOM|Choke DCV shows different PN than DBI|NOCO NOPT NOTE|Poor valve P/N documentation from Housto|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Other causes |Do Not Use
ZF|7101401|25/06/2004|priority 2 |Q3|PETROBRAS|Unknown|Marlim SCM Extension Rod|NOCO NOTE ATCO|Length changed by mistake|Machining related|Length Error|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Engineering related|Design Specification/Drawing error
Q3|7105597|Unknown|priority 3 |Q3|Unknown|Unknown|SCM controlmodule|NOTI NOPT NOCO ATCO|Leak at stab connector.|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZF|100052231|28/10/2010|priority 2 |Q3|CHEVRON|GOM|Bad SIO board readings on SEM A|NOCO ATCO NOPT NOTE|Bad SIO board readings on SEM A|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Other causes/damage |Damage during transport
ZF|P7000000897|04/06/2010|priority 1 |Q3|Unknown|Unknown|EC8 with HW525 inside the hose.|NOPT NOTE NOCO ATCO|HW525 inside the yellow hose|Damage |Damage during assembly|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Operator Error
ZF|P6000042968|02/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Change hydraulic coupler|NOCO ATCO NOPT NOTE|Sharp edge on Male coupler   test equip.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZF|P6000121393|02/10/2015|priority 2 |Q3|Unknown|Unknown|HC1 LEAKING|NOTE ATCO NOPT NOCO|Hydraulic coupler leakage|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Products|Coupler|Vendor related |Equipment Malfunction
ZF|P6000064909|20/03/2012|priority 3 |Q3|Unknown|Unknown|Change of Hydraulic Fluid in Laggan-Torm|NOTE NOCO|Hydraulic Fluid change in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000000897|24/06/2015|priority 1 |Q3|SHELL|Unknown|MMR - Spacer's Thread of Outer Can|ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Damaged during assembly
ZF|P6000068770|07/07/2011|priority 3 |Q3|Unknown|Unknown|Bracket in outercan conflict|NOPT NOTE ATCO NOCO|Bracket conflict inside outercan|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000062990|20/04/2015|priority 3 |Q3|Unknown|Unknown|Water in silicone oil|ATCO NOTE NOPT NOCO|Paint on sealing surface caused leakage|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
Q3|7104033|Unknown|priority 3 |Q3|Unknown|Unknown|Test av ytterkanne mangler i TPR.|ATCO NOCO NOTI NOPT|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Documentation
Q3|7104033|10/05/2000|priority 3 |Q3|Unknown|Unknown|Comms. with wells G3H and G4H not stable|NOPT NOCO ATCO NOTI|Comms transmission frequency/changed|103-Electrical|Modems/Communications|Defect locations - offshore/field|Statfjord C|Initial/Direct product problem|Function
ZF|100030711|28/02/2006|priority 3 |Q3|STATOIL|Unknown|SCM failure|NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000109194|10/04/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100037966|26/06/2012|priority 1 |Q3|Unknown|Unknown|SCM P26  HFT  voltage clarification|NOCO NOTE NOPT|Typo in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|SHE DIV|NOPT ATCO NOTI NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Design
ZF|P6000057855|11/02/2010|priority 3 |Q3|ENI|Unknown|Communication failure SEM|ATCO NOCO NOPT NOTE|Error to be confirmed in QN200153739|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZF|P6000055605|03/10/2011|priority 1 |Q3|Unknown|Unknown|Wrong information on the drawing|NOTE ATCO NOCO NOPT|Wrong temperature on GA DWG(nameplate)|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|7104075|10/02/2006|priority 3 |Q3|SHELL|GOM|FAILURE TO OPPERATE TO PRD REQUIREMENTS|NOTE ATCO NOCO NOPT|PART ACCEPTED-NO NON-COMPLIANCE|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q1|7102643|12/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 17 ÅSG.A S-2H PT Func XOV/AMV malfun|NOCO NOPT NOTI ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZB|P6000088614|02/12/2015|priority 1 |Q1|Unknown|Unknown|Shah Deniz Test Connector and SCM 05|ATCO NOTE NOCO|Used faulty test connector|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000083428|09/01/2013|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000147469|21/11/2017|priority 1 |Q3|Unknown|Unknown|QUALITY ISSUE|ATCO NOPT NOCO NOTE|Unknown|Coating/Plating |Painting Defect|Object Types to Eng Matl CLASS|scm_assy|Vendor related |Coating Defect
ZF|P6000074156|16/07/2012|priority 3 |Q3|Unknown|Unknown|HPDCV 54 failure - SCM 402|NOPT NOCO NOTE ATCO|HPDCV 54 failure|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Lack of Training
ZF|P6000039844|22/09/2010|priority 3 |Q3|Unknown|Unknown|Incorrect prosedure|NOCO NOTE ATCO|Procedure Error  SPC was wrong|Documentation |Procedure / Process Error|SS - Controls -Instrumentation|Other SCM instruments|FMC Engineering related |Procedure error
ZF|100035013|15/02/2007|priority 2 |Q3|Unknown|Unknown|Gammel software|NOCO ATCO NOPT NOTE|Update of procedure|Documentation |Incorrect user documentation (customer)|FKS Quality system issues|Quality Management System|FMC Engineering related |Unknown
ZF|7103233|15/06/2005|priority Unknown|Q3|SUNCOR|Unknown|SIO failure ?|NOTE NOCO NOPT|Not known.|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
Q1|7102643|23/05/2002|priority 3 |Q1|Unknown|Unknown|Åsg 10  internal leak of hydraulic fluid|NOPT NOTI NOCO ATCO|PT defective ref. QN 200003254|Product defects for dept. 1640|1641 SCM (Mech) Valves|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Leakage
Q3|100018082|11/11/2002|priority 3 |Q3|Unknown|Unknown|Blind plug hit mounting base|NOPT NOTI NOCO ATCO|Plug must be mountet from inside.|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZB|P6000039844|28/09/2018|priority 2 |Q1|Unknown|Unknown|Shell GK_ Missed PSM for SCM 25|NOTI OSNO OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000064909|15/09/2011|priority 3 |Q3|Unknown|Unknown|Wiring falure on COVHP and COVLP|ATCO NOPT NOTE NOCO|Marked wrong during assembly.|Assembly Related |OBS-Component TraceabilityNot Maintained|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000063531|23/12/2010|priority 2 |Q3|Unknown|Unknown|Leakage in butech fitting|NOPT ATCO NOTE NOCO|Not tightened after connection to comp|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Assy |Missing Operation
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO NOPT|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR2 Implement RCA Actions_1 RPT10033107|NOPT NOTE NOCO ATCO|Unknown|Unknown|Unknown|SS - Controls - Electronic Boards|Other SEM (Non Standard)|Projects Related|Material error
ZF|100035013|06/02/2008|priority 3 |Q3|SHELL|Unknown|missing batch numbers|NOPT NOCO NOTE|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P6000029747|09/12/2008|priority 2 |Q3|Unknown|Unknown|Protection ring still with thick weld|NOCO ATCO NOPT NOTE|Protection ring can be used as is.|Machining Related |OBS-Outside Diameter Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZD|P6000147859|12/03/2018|priority 1 |Q2|Unknown|Unknown|Marking Issue|ATCO NOCO NOTE|Rev marking not specified|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P6000100953|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100001156|08/03/2006|priority 3 |Q3|STATOIL|NORTH SEA|SCM-10 L-4H GFC AI card SEMA malfunct.|NOTE NOCO ATCO|Failure in AI Card batch|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Compl. & W.Over - XT - R. Tools|Xmas Tree Running Tool for CXT|Vendor related |Material error
ZF|P6000064911|02/11/2011|priority 3 |Q3|Unknown|Unknown|No communication fiber line 2|NOCO NOPT NOTE|No error|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes/damage |QN Cancelled
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|VALUES NOT UPDATING AT SPECIFIED TIME|ATCO NOTE NOCO NOPT|Setting in Top Side SW incorrect|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|7102643|04/10/2000|priority 3 |Q3|Unknown|Unknown|No procedure for IR testing of PT's|NOCO ATCO NOTI NOPT|PRD-000020064 released 26.10.00|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P7000024900|30/07/2014|priority 3 |Q3|Unknown|Unknown|CONCESSION REQUEST|NOTE NOCO NOPT ATCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100038200|02/06/2005|priority 2 |Q3|Unknown|Unknown|SCM 63 NOVA DH procedure|NOPT ATCO NOCO NOTE|Failure during RIT test procedures|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZB|100018600|04/05/2004|priority 3 |Q1|PETROBRAS|Unknown|Vacum pipe SCM#2 not according to design|ATCO NOTE NOCO|Tube was not proper fixed/replaced.|Assembly / Test related |Handling Damage|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Assembly/Test related|Assembly/Test error
ZF|P6000068902|01/09/2011|priority 3 |Q3|Unknown|Unknown|Pressure on PT 11 when opening CVLP 7|NOTE NOPT ATCO NOCO|Operator error  new personnel|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|7103233|09/09/2014|priority 2 |Q3|FRAME AGREEMENT TERRA NOVA|Unknown|Water inside SCM after hyperbaric test.|NOTE ATCO NOCO NOPT|Bad cleanliness caused water ingress|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P7000024900|16/01/2013|priority 1 |Q3|Unknown|Unknown|BC10/39 - Check Valve Tipagem errada.|NOPT NOTE ATCO NOCO|ECN não implementada|Assembly Related |OBS-Component TraceabilityNot Maintained|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Other causes/damage |Cause not found
ZF|P7000001621|20/02/2013|priority 1 |Q3|Unknown|Unknown|COVHP com Vazamento Hérc Ug.15|ATCO NOTE NOCO NOPT|SCM MMR|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Maintenance
ZF|100029149|11/03/2004|priority 4 |Q3|TOTAL|WEST AFRICA|Problems with DHI during Hyperbaric|NOPT ATCO NOCO NOTE|Wiring personell used wrong Rev.|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Electrical|Wiring|FMC Assembly/Test related|Assembly/Test error
ZF|100037965|11/01/2011|priority 4 |Q3|Unknown|Unknown|Investigation BP SCM Failures|NOPT NOCO ATCO NOTE|Ref QNR text|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Vendor related |Clarification
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|SCM is venting control fluid offshore|ATCO NOPT NOCO NOTI|Worn seat in CV due to customer mat.reqm|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Shell Alliance GOM|Root cause Other|Customer-Customer error
Q3|7103233|19/11/1999|priority 2 |Q3|Unknown|Unknown|Install hydaulic flow restrictors|NOCO ATCO NOTI NOPT|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
Q3|7102643|13/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM not cleaned prot.and preserv.missing|NOPT NOTI ATCO NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Cleanliness
ZF|P7000039672|18/09/2014|priority 1 |Q3|Unknown|Unknown|Interferência Plug f/filter Linha F2- LP|NOCO ATCO NOTE NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Specification not followed
ZF|100037428|08/04/2016|priority 2 |Q3|Unknown|Unknown|Worn out threads|NOPT ATCO NOTE NOCO|Wear|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000083428|10/09/2012|priority 3 |Q3|Unknown|Unknown|HC72 to be replaced with blind coupler|ATCO NOTE NOPT NOCO|BOM needs update. Wrong PN on HC72|Change/Deviation Request |Part substitution request|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Specification error
ZF|P6000121268|27/03/2015|priority 4 |Q3|Unknown|Unknown|(CDM)SCM EC6 Damage - ENI Jangkrik|ATCO NOPT NOTE NOCO|Electrical connector damage|Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|El. Connector|FMC Test |Damaged during testing
ZF|P6000076121|20/08/2011|priority 3 |Q3|Unknown|Unknown|No communication with MPFM|NOPT NOCO NOTE ATCO|Wiring fault. Human error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000016420|27/09/2011|priority 1 |Q3|Unknown|Unknown|Revestimento da bucha em desacordo|NOTE NOPT NOCO ATCO|REVESTIMENTO|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|QA/QS/QI Related|Goods Receiving Inspection error
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|Choke Valve failure|NOTE ATCO NOCO NOPT|Wear in pilot stage.|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Shell Alliance GOM|Root cause Vendor|Material/Component error
ZB|100001156|02/06/2004|priority 4 |Q1|STATOIL|NORTH SEA|SCM delivered with blind plugs|NOCO NOTE ATCO NOPT|Unknown|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Hydraulic couplers|Other external causes|Customer Error/responsibility
Q3|100009059|07/02/2001|priority 1 |Q3|Unknown|Unknown|SCM damaged by shipping company|NOCO NOPT NOTI ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Work Shop|Root cause Other|Logistics-Packing/Shipping Damage
Q3|7104670|08/11/2001|priority 3 |Q3|Unknown|Unknown|Hook-up & Function Test|NOTI ATCO NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Root cause Engineering|Test Procedure error
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOPT NOCO ATCO NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
Q2|7100320|03/11/1999|priority 3 |Q2|Unknown|Unknown|Oppgrader Hercules 09|ATCO NOTE NOCO NOPT|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Unknown|Unknown|Initial/Direct product problem|Function
ZF|P6000069056|28/11/2011|priority 3 |Q3|Unknown|Unknown|Wiring ERROR EC3  EC4 and EC5 O.C.T|NOCO NOTE NOPT|Opr. failure during SCM wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100056443|23/02/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|Addition of Grounding Power-can|NOPT NOCO ATCO NOTE|Design improvement for safety precaution|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZD|7104075|18/12/2014|priority 3 |Q2|Unknown|Unknown|Crrosion on ECs|NOTE NOCO ATCO NOPT|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Packaging/Handling
ZD|P6000028371|14/08/2012|priority 2 |Q2|Unknown|Unknown|SEM Software Defect|NOTE ATCO NOCO NOPT|SEM Software Defect|Design |Procedure Error|Common/Misc - General|Software|FMC Engineering related |Procedure error
ZF|100017305|10/10/2016|priority 2 |Q3|Unknown|Unknown|CR Fram Vest FD012 SCM|NOPT NOCO ATCO NOTE|Customer take responsibility for deviati|Software |Component Failure|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|7105597|19/10/2010|priority 2 |Q3|PETRO SA; MOSSEL BAY|Unknown|Material not delivered to plant|NOTE NOCO|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|P7000001621|02/08/2010|priority 1 |Q3|Unknown|Unknown|Fechamento da outer can|ATCO NOCO NOPT NOTE|Usinagem realizado em defasagem|Machining Related |OBS-Angle error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Machine Shop Personnel |Operator error
Q3|7100320|Unknown|priority 3 |Q3|Unknown|Unknown|Skifte solenoider Hercules sn-13|ATCO NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100001156|13/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|SCM 7 GFA Rimfaks J-4H HP Hyd. leak.|NOPT ATCO NOCO NOTE|Bolt failure on blind plate|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
Q3|7101172|25/10/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOPT NOCO ATCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|100026567|25/06/2003|priority 2 |Q3|Unknown|Unknown|Leak in SCM HPI on production XT|NOCO NOPT NOTE|Ref. QN 200015669|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Pressure intensifier|Vendor related|Material error
Q1|100018082|29/10/2002|priority 2 |Q1|Unknown|Unknown|Mikkel SCM/WOCS SW interface mismatch|NOTI NOPT NOCO ATCO|Unknown|250-Hydraulic/WOCS/ICS equipment|Workover Control Panel (WOCS)|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Function
Q3|7102643|20/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM on J3-H  Hyd leakage in HP system|ATCO NOTI NOCO NOPT|2 bolts on control valve broken|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Leakage
ZF|P6000068924|20/06/2012|priority 3 |Q3|TOTAL|Unknown|ground straps found with poor crimp|NOTE NOCO|Poor wire-crimps on ground straps|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
Q3|100025735|13/02/2003|priority Unknown|Q3|OVERALL PROJECT ROLL-UP SKIRNE / BYGGVEWELL NO C-1H|Unknown|Guidepins on top of Outer Can SCM#1|NOTE NOPT NOCO ATCO|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZB|100055600|27/10/2008|priority 2 |Q1|TALOS|GOM|SCM #96 has a hydraulic leak subsea.|NOCO NOPT NOTE|SCM #96 has a hydraulic leak subsea|Test Related |OBS-Leakage (Fluid)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Cause not found
ZF|P7000016420|15/07/2011|priority 1 |Q3|Unknown|Unknown|Minimum flow failure|NOCO ATCO NOTE NOPT|Flow technology|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
Q3|7104033|Unknown|priority 3 |Q3|Unknown|Unknown|Tests missing after mounting of Outercan|ATCO NOPT NOCO NOTI|KOS documentation error|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider på ventiler.|NOTI NOCO NOPT ATCO|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
ZF|100030542|29/01/2008|priority 3 |Q3|BAOBAB ADD. XT P11/P12|Unknown|Batch numbers missing in iBASE list|NOPT NOCO NOTE|Change: batch cert. to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|100015314|09/10/2001|priority 2 |Q3|Unknown|Unknown|Hydraulic assy mod: bypass valve/filter|NOCO NOPT NOTI ATCO|Improvements to meet NH cleanliness spec|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Product Not Qualified
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|Missing rubber prot.inside comp. chamber|NOCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|100035013|10/06/2008|priority 3 |Q3|Unknown|Unknown|Flow direction wrong on drawing|NOCO NOPT NOTE ATCO|Unknown|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Causes for Improvement|Documentation
ZF|P7000039672|14/01/2015|priority 1 |Q3|Unknown|Unknown|Conector pago sem mangueira|NOCO NOPT ATCO NOTE|Unknown|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Missing Parts
Q1|7104033|28/02/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 2 SF Nordfl. SEMA A/I card malfunct.|NOTI ATCO NOPT NOCO|Unknown|103-Electrical|SEM El.Rack|Defect locations - offshore/field|Statfjord C|Initial/Direct product problem|Function
ZE|P6000088751|26/02/2016|priority 3 |Q3|Unknown|Unknown|WEL PSM not followed(NA)|NOCO NOTE NOPT ATCO|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Lack of training
ZB|P6000105710|01/09/2016|priority 2 |Q1|Unknown|Unknown|Julia IWCS lack of comms|ATCO NOCO NOTE|See above.|Software |Other- Specify in comments|SS - Controls - Electric Products|Other Electric Products|Software |Other- Specify in comments
ZF|P6000104112|08/09/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000104116|23/09/2014|priority 3 |Q3|Unknown|Unknown|O-ring sealing surface fault|NOTE NOCO NOPT ATCO|O-ring surface not according to DWG|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000121268|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOTE NOPT NOCO ATCO|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZE|7102643|01/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|DHI 109 config file|NOPT NOCO ATCO NOTE|Unknown|Unknown|Unknown|SS - Controls - Topside Products|N/A SW|Accepted -&|Accepted
ZE|P6000147469|05/03/2018|priority 1 |Q3|Unknown|Unknown|CNOOC Wenchang  EHXT  PT Sensor Issue|OSTS OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|100016711|22/01/2014|priority 3 |Q2|Unknown|Unknown|EC Loss of Connectivity|NOCO NOTE NOPT ATCO|Unknown|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Connector|Vendor related |Equipment Malfunction
ZF|7104075|22/07/2005|priority 3 |Q3|SHELL|GOM|INTERNAL PT OUT OF RANGE|NOTE NOPT NOCO ATCO|INTERNAL PT OUT OF RANGE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100056443|26/10/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|Wrong Clock frequency|NOCO NOTE|Unknown|Raw Material |OBS-Dimensional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |Cause not found
Q3|7100320|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Hercules SCM 01|NOPT ATCO NOCO NOTI|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|P6000093501|21/11/2012|priority 3 |Q3|Unknown|Unknown|Smart return PT missing in signatur|NOTE ATCO NOCO NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Engineering related |Engineering Error
ZF|P6000083395|15/03/2012|priority 3 |Q3|TOTAL|Unknown|Fault in sensor schematics|NOTE NOPT NOCO ATCO|Not relevant QN.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZE|P6000093498|20/10/2016|priority 2 |Q3|Unknown|Unknown|LLP WOCM unable to communicate with WCP|NOPT ATCO NOCO NOTE|Equipment damaged by lightnig|Unknown|Unknown|SS - Controls - Electronic Boards|Eth.net items|Electrical |Other- Specify in comments
ZF|7102969|13/07/2005|priority 3 |Q3|Unknown|Unknown|Pressure readings with 0 bar supply|ATCO NOCO NOTE NOPT|Pressure readings with 0 bar supply|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P6000074156|30/01/2013|priority 3 |Q3|Unknown|Unknown|DHI 204 SEM B error in report log|NOCO NOTE NOPT|Incident described  SCM is fully working|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
Q3|7104020|Unknown|priority 2 |Q3|Unknown|Unknown|TPR-0011028  Factory Acceptance Test.|NOTI NOPT NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Tank test|Initial/Direct product problem|Documentation
Q3|7100320|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrade Hercules SCM 08|NOPT NOTI ATCO NOCO|Wrong material|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|Waiver hyperbaric test on SCMs 2 & 3|ATCO NOTI NOCO NOPT|Waiver tank test after re-opening|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
ZF|P7000000897|10/11/2011|priority 1 |Q3|Unknown|Unknown|Damaged part during assembly|NOPT ATCO NOTE NOCO|Montagem incorreta danificando peça|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Assy |Operator Error
ZB|100049000|19/01/2007|priority 2 |Q1|BP|Unknown|Press transducer reading 2000PSI high.|NOCO NOTE NOPT|Unknown|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Test error
Q3|7104670|15/09/2000|priority 3 |Q3|Unknown|Unknown|XT / SCM / TH|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
ZB|100035400|08/05/2007|priority 1 |Q1|Unknown|Unknown|SCM compensation Bladder leaking|NOPT NOTE NOCO|SCM compensation Bladder leaking|Damage |Unknown|Subsea Control Module (SCM) Hydraulic|Compensators|Vendor related |Equipment Malfunction
ZD|100016901|06/09/2013|priority 3 |Q2|Unknown|Unknown|Incorrect coating (B)|ATCO NOCO NOTE|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|Vendor related |Specification not followed
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|Shell SCM Loss of Hydraulic fluid|NOCO NOTI NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|SCM Change Hydraulic Fluid|ATCO NOCO NOTE|SCM shipped to be reflushed|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 05  Bytting av solenoider|NOPT NOCO ATCO NOTE|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000116360|10/06/2014|priority 4 |Q3|Unknown|Unknown|EC3 is loose.|NOCO ATCO NOTE|Holes re-threaded  no investigation|Machining Related |OBS-Length/Depth Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000001621|18/02/2011|priority 1 |Q3|Unknown|Unknown|Problemas com rosca interna|ATCO NOPT NOCO NOTE|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000101955|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100016711|04/08/2011|priority 2 |Q3|BP|GOM|EC conectors pitted/corroded.|NOCO ATCO NOTE|EC connectors pitted / corroded|Damage |Damage from corrosion|SS - Controls - Electric Products|Electrical Connector|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000000897|25/09/2018|priority 3 |Q3|SHELL|Unknown|MMR - Failure During DCV 23 open SEM B|NOCO ATCO NOTE|Unknown|Assembly |Assembled Incorrectly|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Assy |Operator Error
ZF|100026567|18/05/2004|priority 3 |Q3|STATOIL|NORTH SEA|THE SCM IS LEAK|ATCO NOTE NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000062454|29/11/2012|priority 2 |Q3|Unknown|Unknown|Sofware version upgrade|NOCO NOTE ATCO|Software version upgrade.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000104114|31/10/2014|priority 3 |Q3|Unknown|Unknown|AI reading from PSDM outside criteria|NOCO NOTE ATCO NOPT|Magnetic SEM canister|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZB|7102643|15/11/2008|priority 4 |Q1|STATOIL|NORTH SEA|F&D Over torque on SCM|ATCO NOCO NOTE NOPT|Incorrect op. of the 2700 Nm torque tool|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Operator Error
ZF|100058509|23/02/2011|priority 3 |Q3|LLOG|GOM|Missing documents & sign offs|ATCO NOCO NOTE NOPT|missing documents & sign offs|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000055605|08/07/2014|priority 3 |Q3|Unknown|Unknown|LP return flowmeter low flow failure|NOPT ATCO NOCO NOTE|See ZD QN 200392890|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|P7000001621|06/03/2018|priority 4 |Q3|Unknown|Unknown|MMR - Compensator Bladder Leakage|ATCO NOTE NOCO|Unknown|Damage |Damage during assembly|Object Types to Eng Matl CLASS|scm_components|FMC Assy |Damaged during assembly
ZE|100035119|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|NOCO ATCO NOTE|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|100020278|25/02/2011|priority 1 |Q3|Unknown|Unknown|cylindricalpin bunner mot blokk og plate|NOTE NOCO ATCO NOPT|Guide pin too long|Machining Related |OBS-Length/Depth Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|3812476|16/07/2008|priority 4 |Q3|STATOIL|NORTH SEA|Not full information regarding SCM 07|NOTE NOPT NOCO|SEM address not ready prior to offshore|Documentation |Missing user documentation (customer)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Planning error
ZD|100035118|06/12/2007|priority 1 |Q2|PETRONAS|Unknown|Missing Documentation|NOTE ATCO NOCO NOPT|Failure to Make Instructions clear.|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Planning error
ZB|7101172|16/03/2006|priority 3 |Q1|STATOIL|NORTH SEA|SCM 10 GFA  I-4H SEMA com.failure|NOTE NOCO NOPT|Unknown reason for failure|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
Q3|100015538|05/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM 9 NORNE upgrade DHI107/LP-Accu.|NOCO ATCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Root cause Engineering|Material fault
Q3|7105128|25/05/2000|priority Unknown|Q3|Unknown|Unknown|SCM P 04|NOPT ATCO NOCO NOTI|Connectors incorrectly installed on SCMB|101-Mechanical|SCM Mounting Base|Defect locations - onshore|KOS Kbg. SCM-EFAT|Initial/Direct product problem|Damages
ZE|P6000126219|21/01/2016|priority 3 |Q3|Unknown|Unknown|adjust silicon compensator volume|ATCO NOTE NOCO|Part updated|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000000229|06/08/2013|priority 1 |Q3|Unknown|Unknown|Concessão de fluido  SCM #21 FRADE|NOPT NOCO NOTE ATCO|Concessão para utilização de fluído|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100048038|10/05/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|Leak Detector fails during Hyperbaric|ATCO NOCO NOTE NOPT|Decision made by Client|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
Q3|100018600|06/02/2003|priority Unknown|Q3|Unknown|Unknown|Upgrade of C-can.|NOTI ATCO NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000008275|10/03/2011|priority 1 |Q3|Unknown|Unknown|Teste de vacuo da outer can|NOTE ATCO NOCO NOPT|Outer can test|Coating/Plating |Incorrect Colour/Coating|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|100025661|27/04/2006|priority 3 |Q3|Unknown|Unknown|Difference in marking on drawings|NOPT NOTE NOCO ATCO|letter size difference|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Do Not Use
Q3|7104670|08/11/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOTI NOCO ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q1|7102643|Unknown|priority 3 |Q1|Unknown|Unknown|Documentation - SCM missing punch list|ATCO NOPT NOTI NOCO|Uklare retningslinjer|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen goods receipt/inspection|Initial/Direct product problem|Documentation
ZB|100020278|03/12/2008|priority 2 |Q1|EXXONMOBIL|Unknown|08-MEGI-020: AIB Voltage Reference Error|NOCO NOTE|08-MEGI-020: AIB Voltage Reference Error|FMC Other Defect |Functional|Subsea Control Module (SCM) Electrical|Other PCBs|FMC Other causes/damage |Cause not found
ZF|P6000104111|18/01/2016|priority 2 |Q3|Unknown|Unknown|SCMs Fliud Issue for PXT|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000001621|23/07/2015|priority 2 |Q3|PETROBRAS|Unknown|MMR - HW Leakage during In-House|NOTE ATCO NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Missing Parts
ZB|P6000042969|24/09/2010|priority 2 |Q1|Unknown|Unknown|Punch List SCM IXT 13|NOPT ATCO NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100064910|11/03/2015|priority 3 |Q3|Unknown|Unknown|Wrong bolts in BOM for SEM el-can.|NOCO ATCO NOTE|Wrong screw P/N is listed in BOM|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000104115|03/07/2014|priority 4 |Q3|Unknown|Unknown|Missing parts on EC-assy|ATCO NOTE NOCO NOPT|EC assy not compleate follow-up200386426|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Missing Parts
ZB|100037428|04/05/2011|priority 4 |Q1|Unknown|Unknown|110402 - GIRRI_TOTAL_SONILS_WOR memo|NOCO ATCO NOTE NOPT|Unknown|Machining Related |OBS-Position Error|Stage Gate Review|Customer Support Logistics Plan|FMC Materials/Stores related |Improper Handling
ZF|100035013|05/06/2008|priority 3 |Q3|SHELL|Unknown|Batch numbers missing|NOTE NOCO NOPT|Diffrent batcnumber on screws|Documentation |Missing Certificates / Records|FKS Quality system issues|Quality Management System|FMC Materials/Stores related |Unknown
Q3|7102643|Unknown|priority 2 |Q3|Unknown|Unknown|Acceptance criteria flow in CIDV on SCM|NOPT NOTI NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 03 ÅsgB Y-3H PT LP Supply malfunct.|NOTI NOPT NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
ZF|140-141-004|03/12/2010|priority 2 |Q3|Unknown|Unknown|Vazamento da Câmara Hiperbárica|NOCO NOTE ATCO|Vazamento no Jumper el. Durante Hiperb|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q1|7101172|05/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 12 GFA J-5H Comm. problems SEMA|ATCO NOCO NOTI NOPT|Unknown|103-Electrical|Modems/Communications|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Function
Q2|7102969|Unknown|priority 1 |Q2|Unknown|Unknown|Ytterkanne har maling flakket av.|ATCO NOPT NOTE NOCO|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|P6000116166|25/09/2014|priority 3 |Q3|Unknown|Unknown|Unstabile communication Tullow Ten|NOTE ATCO NOPT NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SCU SW|FMC Engineering related |Engineering Error
ZB|P6000080678|12/01/2017|priority 3 |Q1|Unknown|Unknown|WEL  SCM  Cleanliness procedure|ATCO NOCO NOPT NOTE|Unknown|Documentation Requirement |Procedure / Process Error|Object Types to Eng Matl CLASS|scm_mkIIE|QA/QS/QI Related|Documentation error
ZF|100018082|21/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|Burned components in SEM B|ATCO NOPT NOCO NOTE|FMC Test: Damaged during testing|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P6000050867|23/03/2011|priority 2 |Q3|Unknown|Unknown|SW Error|NOPT NOTE ATCO NOCO|Programmer Error|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
Q1|100018532|26/08/2002|priority 3 |Q1|SHELL|Unknown|SCM 1 Bijup.&Salema PT IMV. malfunction|NOCO NOPT NOTI|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Unknown|Unknown|Initial/Direct product problem|Function
ZB|P6000031350|12/08/2008|priority 1 |Q1|Unknown|Unknown|Remaining b-punches at receival  Bergen|NOTE NOCO ATCO|Unknown|FMC Other Defect |Unknown|Customer Compliant|Noncompliance to Customer Requirement|FMC Other causes/damage |Unknown
ZF|P6000083428|10/09/2012|priority 3 |Q3|Unknown|Unknown|HC72 to be replaced with blind coupler|NOCO NOPT NOTE ATCO|Replacement of PN in mech&SCM w\o BOM|Change/Deviation Request |Part substitution request|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Continuous Improvement
ZD|P6000042969|13/05/2009|priority 1 |Q2|Unknown|Unknown|Cards fails to read gauges|NOCO NOPT NOTE|New DHI interfaces & behaviour|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Unknown
ZF|P7000024900|18/02/2013|priority 1 |Q3|Unknown|Unknown|Não conformidade na rosca da base plate|NOTE NOPT NOCO ATCO|Não conformidade na rosca da base plate|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Cause not found
ZF|100020562|19/08/2010|priority 1 |Q3|BP|GOM|Damaged Part.|NOCO NOPT ATCO NOTE|Cause not Found- RCA  in process|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZB|3812476|22/11/2006|priority 1 |Q1|STATOIL|NORTH SEA|Damaged exhaust lines on SCM # 12 Norne|NOCO NOPT NOTE ATCO|Pipes corroded|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|7102969|09/05/2005|priority 3 |Q3|Unknown|Unknown|Broken bolt|ATCO NOPT NOTE NOCO|Component failure|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100048038|19/02/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|PROCEDURE REVISION|NOTE NOPT ATCO NOCO|PROCEDURE ERROR|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000001621|01/06/2012|priority 1 |Q3|Unknown|Unknown|Substitução do PT di Hércules #11|NOTE NOCO NOPT ATCO|Degradação ( PT Antigo)|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOTE NOPT ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZD|100034440|10/09/2005|priority 3 |Q2|Unknown|Unknown|Missing Documentation|NOTE NOCO ATCO NOPT|Documents errors|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|P6000069056|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|Insufficient wall thickness in m. block|NOCO ATCO NOTE NOPT|Ref. QN 200241870|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
ZF|P7000001843|14/01/2011|priority 1 |Q3|Unknown|Unknown|Parafuso quebrado|NOTE NOCO ATCO NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|100034440|30/11/2010|priority 2 |Q3|HOUSTON STOCKING MK IV|Unknown|Class 1 ECN 6083510|ATCO NOCO NOTE NOPT|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000068912|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|7100320|13/04/2004|priority 3 |Q3|PETROBRAS|Unknown|SCM Herc. 19 DO-150  card failure|ATCO NOCO NOTE NOPT|Part is not available for investigation.|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Other causes|Miscellaneous
ZF|100037966|20/01/2009|priority 1 |Q3|BP|Unknown|B18 SCM  - SEM A communication problems|NOCO NOTE|Unknown|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|100052231|28/01/2015|priority 3 |Q3|Unknown|Unknown|Changing AI150 cards in both sems|NOPT NOTE ATCO NOCO|AI-board design upgrade (U9  ADC150)|Change/Deviation Request |Part substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000000897|11/05/2012|priority 1 |Q3|Unknown|Unknown|Adapter plate apresenta avarias|NOPT NOCO NOTE ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|P6000065886|11/03/2011|priority 2 |Q3|Unknown|Unknown|assemble the Outer can to the module|ATCO NOPT NOCO NOTE|Vacume pipe in module positioned wrong|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
Q3|3794920|13/11/2000|priority 3 |Q3|STATOIL|NORTH SEA|SCM was stuck in Transportation Skid|NOPT NOTI ATCO NOCO|Dirt and rust?|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider på ventiler.|NOPT NOTI ATCO NOCO|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
ZF|P6000042969|28/01/2015|priority 3 |Q3|Unknown|Unknown|Missing pins|NOTE NOCO|Gone missing during transport|FMC Other Defect |Part Lost|SS - Controls -SCM  hyd/mech components|Outer Can|Intercompany|FMC Dunfermline
ZE|7104033|05/11/2018|priority 1 |Q3|Unknown|Unknown|GC 187201 wrong tag/use of procedure|ATCO NOCO NOTE|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Marking |Missing Marking
ZF|P7000000897|06/10/2017|priority 3 |Q3|SHELL|Unknown|MMR - Base Plate With Coating Damage|NOTE NOCO|Failure During Transport|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Baseplate|Paintshop Related|Operator error
ZB|P6000042969|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 14|NOPT NOTE ATCO NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000039672|17/07/2017|priority 1 |Q3|Unknown|Unknown|SEM A did not communicate|NOPT ATCO NOTE NOCO|Unknown|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIIE|Intercompany|FMC Kongsberg
ZF|P6000039844|16/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)Found old software|NOPT NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - Topside Products|N/A Smart Tool|FMC Other causes/damage |Cause not found
Q1|100020278|14/01/2003|priority 2 |Q1|Unknown|Unknown|SCM test equipent not calibrated|ATCO NOCO NOTI NOPT|Workshop using un-calibrated equipment|103-Electrical|SEM Powersupply|Defect locations - onshore|KOS Kbg. SCM-Montasje|Administrative causes|Q-system procedures not adhered to
ZF|100037427|28/08/2007|priority 2 |Q3|Unknown|Unknown|Lack of protection Cap SCM MB|NOPT NOCO NOTE|No error|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Other causes |No Non-Compliance
ZF|7104075|02/02/2011|priority 2 |Q3|SHELL|GOM|Missing Sign offs|ATCO NOCO NOPT NOTE|missed sign offs|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P6000121268|12/06/2015|priority 3 |Q3|Unknown|Unknown|Missing support ring & O-ring|ATCO NOTE NOCO NOPT|Investigation in QN 200446598|Procurement |Incomplete Kit Of Parts|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Specification not followed
ZF|P6000150910|11/09/2018|priority 3 |Q3|Unknown|Unknown|Part is not as specification|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|P6000133916|03/08/2017|priority 2 |Q1|Unknown|Unknown|Moho IRCD Communication with SEM615|NOTI NOPR OSTS NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100037965|11/03/2009|priority 1 |Q3|BP|Unknown|SIO board failure for DHG 109 SEM A|NOTE NOCO|I/O board failed|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
Q1|7103234|23/04/2002|priority 3 |Q1|SUNCOR CPI|Unknown|SCM MIV function line PT malfunctioning|ATCO NOPT NOCO NOTI|Suspect internal electronic fault in PT|103-Electrical|Pressure Transducer|Defect locations - offshore/field|FPSO Terra Nova|Initial/Direct product problem|Function
ZF|P6000037365|26/08/2008|priority 2 |Q3|Unknown|Unknown|Wrong Hydraulic Fluid Used During FAT|NOCO NOTE NOPT ATCO|Wrong Hydraulic Fluid Used During FAT|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|100026567|05/05/2010|priority 2 |Q3|Unknown|Unknown|Vigdis OH-01 overhaul SCM # 4|NOCO ATCO NOTE|Sensor simulator has been modified|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|7103233|13/10/2014|priority 2 |Q3|Unknown|Unknown|EC`s in baseplate not grounded.|NOTE NOCO ATCO|Ground wires not mounted|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100037967|16/02/2015|priority 4 |Q3|Unknown|Unknown|Concession raised to accept SCM M9|NOTE NOCO ATCO NOPT|wear and tear|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Service Related:|Damaged during installation
Q3|7104033|Unknown|priority 3 |Q3|Unknown|Unknown|urenheter etter systemtest|NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|P6000080678|26/07/2012|priority 3 |Q2|Unknown|Unknown|Modbus Slave ID Mismatch for WGM|NOCO NOTE ATCO NOPT|Modbus Slave ID Mismatch for WGM|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Incorrect set up
ZF|P6000028371|27/09/2007|priority 3 |Q3|Unknown|Unknown|SCM wired according to wrong revision|NOPT ATCO NOTE NOCO|wired with previous rev|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100051269|27/09/2006|priority 3 |Q3|STATOIL|NORTH SEA|Assembly  Workshop error|NOCO NOPT ATCO NOTE|drawing error|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|7104075|06/06/2006|priority 3 |Q3|SHELL|GOM|INTERNAL PT FAIL IR TEST|NOPT NOCO NOTE ATCO|INTERNAL PT FAIL IR TEST|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZB|7100320|23/05/2003|priority 3 |Q1|PETROBRAS|Unknown|SCM 9 Hercules AIDO failure SEM A/B|NOTE NOCO NOPT ATCO|Unknown|Assembly / Test related |Material Faulty|Subsea Control Module (SCM) Electrical|Other PCBs|Vendor related|Material error
ZF|P6000043122|28/09/2009|priority 2 |Q3|TOTAL|WEST AFRICA|Wrong P/N on ESRS card?|NOCO NOTE ATCO NOPT|Missing or insufficient marking|Assembly Related |Unknown|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Unknown
ZF|P1000018406|30/01/2009|priority 2 |Q3|BP|GOM|BP Thunder Horse DFCM|NOTE ATCO NOPT NOCO|No Non-compliance-Use As Is|Machining Related |OBS-Inside Diameter Error|SS - Controls - Hydraulic Couplers|Hydraulic Coupler|FMC Other causes/damage |No Non-Compliance
ZF|P6000060453|05/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|No response from FSM|ATCO NOPT NOTE NOCO|Problems with the Com port on the ETU PC|Test Related |OBS-Component Error|SS - Controls - Topside Products|N/A SW|FMC Test |Incorrect set up/testing
ZF|100033987|04/06/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOCO NOTE NOPT ATCO|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|P7000039672|10/12/2015|priority 1 |Q3|Unknown|Unknown|SEM Bracket oxidada.|ATCO NOPT NOCO NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|SEM Bracket|FMC Materials/Stores related |Improper Packaging & Storage
ZD|P6000042308|19/09/2009|priority 3 |Q2|TULLOW|WEST AFRICA|COC HAS INCORRECT SERIAL #|NOPT NOCO NOTE ATCO|C OF C HAS WRONG SERIAL #.|Documentation |Unknown|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Vendor related |Unknown
ZF|100055762|15/06/2010|priority 3 |Q3|Unknown|Unknown|B&B Missing SEM adr marking on sign|NOTE NOCO|Old generation marking plates|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
Q3|7101172|26/04/2000|priority 3 |Q3|STATOIL|NORTH SEA|No temperature reading on SEMB  well K4H|NOPT NOTI ATCO NOCO|-5V Power Supply on SEMB|103-Electrical|SEM El.Rack|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|P6000104111|25/01/2019|priority 4 |Q3|TOTAL|Unknown|Plan Loadout of P18 SCM without full Mob|OSTS NOPT OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7102643|16/07/2002|priority 3 |Q1|Unknown|Unknown|SCM 35 ÅsgA R1-H PT HP Supp. malfunction|ATCO NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 10|NOTE ATCO NOPT NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100027228|04/06/2003|priority 3 |Q3|Unknown|Unknown|FAIL WIYH CPU SOFTWARE|NOCO NOPT NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7101401|Unknown|priority 3 |Q3|Unknown|Unknown|Utskifting sn 07|NOPT NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000083428|16/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7100320|Unknown|priority Unknown|Q3|Unknown|Unknown|Oppgrader Hercules 04|NOCO NOPT ATCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104670|Unknown|priority 1 |Q3|Unknown|Unknown|LVDT1 readings are too low when testing|NOTI NOCO ATCO NOPT|AICF card failure  wrong test equip used|Product defects for dept. 1640|1641 SCM (El) Electronic Card|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P7000000897|24/09/2012|priority 1 |Q3|Unknown|Unknown|BC10-36 Fio solto no conector SIOLT1:P1|NOPT ATCO NOTE NOCO|Operator error in Kongsberg|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Intercompany|FMC Kongsberg
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 07  Bytting av trykktrandsusere|ATCO NOPT NOTE NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
Q1|100006609|28/02/2003|priority 3 |Q1|PETROBRAS|Unknown|SCM 2 Roncador Tube conflict inside can|NOTI NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Root cause Engineering|Other Product Design error
ZF|7104033|16/08/2004|priority 3 |Q3|STATOIL|NORTH SEA|440 v on HXT/SCM dur. skidding on TOA|NOPT ATCO NOTE NOCO|Wrong handling on deck during SU test|Assembly / Test related |Handling Damage|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Operation/maintenance related |Handling/transportation/lifting error
ZF|7105129|13/06/2003|priority 3 |Q3|Unknown|Unknown|4 PIN CONNECTOR INSTEAD OF BLANKING PLUG|NOPT ATCO NOTE NOCO|Error in configuration engineering|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Engineering related|Design Specification/Drawing error
Q3|7104670|21/09/2000|priority 2 |Q3|Unknown|Unknown|No comms with FSM via SCM well D-2H|NOPT NOTI NOCO ATCO|Damaged connector on FCM harness(SCM OK)|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
Q1|7103234|13/07/2000|priority 2 |Q1|Unknown|Unknown|Compensation bladder extruded and burst|ATCO NOPT NOTI NOCO|Unknown|101-Mechanical|Outer Can|Ext. Loc. - St.Johns (Canada)|Goods Receipt|Initial/Direct product problem|Leakage
ZF|P6000100953|28/11/2013|priority 3 |Q3|Unknown|Unknown|To short threads in outercan|NOPT NOTE NOCO ATCO|Interface with EC adapter verified OK|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |No Non-Compliance
ZD|P6000077632|21/09/2015|priority Unknown|Q2|Unknown|Unknown|Defect on delivery|NOTE NOCO|Certification Issue|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100050519|26/02/2015|priority 3 |Q1|Unknown|Unknown|SCM# failure after reworks|NOTE ATCO NOCO|outside warranty period|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|SCM 15  SEM A Analog Card & HP PT Angus3|NOCO NOPT NOTE|Unknown|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other PCBs|Vendor related |Equipment Malfunction
ZF|3801623|28/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|NO VACUUM DURING FILLING OF OUTERCAN|ATCO NOCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100005667|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOPT NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|100034440|03/01/2006|priority 3 |Q3|LLOG|Unknown|HIGH RESISTANCE VALUE|NOCO NOPT ATCO NOTE|Higher Resistance than Specification|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|100016901|15/01/2003|priority 3 |Q3|BP|GOM|o-ring on EC2 on top of SCM clipped|NOPT NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Work Shop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P6000063633|01/07/2011|priority 3 |Q3|ENI|Unknown|incorrect rev of procedure is used|NOPT NOTE ATCO NOCO|Follow-up in QN200214316|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000098616|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|HFT ACCEPTANCE CRITERIA NOT MET|NOTE NOPT NOCO ATCO|HFT DOC. & TEST UNIT DISCREPANCY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|SCM Change Hydraulic Fluid|NOTE ATCO NOCO|SCM shipped to be reflushed|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100050383|19/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|Diode missing between SEM A and SEM B|NOPT NOTE ATCO NOCO|Missing diode-coupling in DO-outputs|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZD|P6000065528|04/04/2011|priority 3 |Q2|Unknown|Unknown|blindelokket passer ikke til ytterkanna.|NOTE ATCO NOCO NOPT|Dim on blind plate does not fit OC|Machining Related |OBS-Outside Diameter Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|100037965|27/06/2012|priority 2 |Q3|Unknown|Unknown|SCM I05  HFT  PRD voltage clarification|NOPT NOTE NOCO|Typo in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000000897|03/03/2011|priority 1 |Q3|Unknown|Unknown|Flowmeter HP not reading|NOTE NOPT ATCO NOCO|It was not possible read minimum flow|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZB|7104075|30/03/2009|priority 2 |Q1|SHELL|GOM|Control Failure/Issue|ATCO NOCO NOPT NOTE|Operator Error|Test Related |OBS-Function|Subsea Control Module (SCM) El. act.syst|Control electronics|FMC Test |Operator Error
ZF|7104670|14/08/2003|priority 3 |Q3|STATOIL|NORTH SEA|Failure on SIO-card ?|NOCO NOTE NOPT ATCO|Filling port not closed.|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Mech w/MB|One atmosphere canisters|FMC Assembly/Test related|Assembly/Test error
ZF|P6000088604|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOPT NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7101401|22/05/2002|priority 2 |Q1|PETROBRAS|Unknown|SCM 4 Marlim untight screws in block|NOCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Leakage
ZB|100048038|13/12/2006|priority 2 |Q1|CHEVRON|WEST AFRICA|SCM LP return leaking.|NOPT ATCO NOCO NOTE|Wrong Pressure used to function SCM|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000083428|04/12/2012|priority 2 |Q3|Unknown|Unknown| Error on SALD sensor|NOCO NOTE NOPT|Faulty test equipment|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|Other el/opt components|FMC Test |Incorrect set up/testing
Q3|7102969|Unknown|priority 3 |Q3|Unknown|Unknown|Bytte av solonoider og senterlås.|NOCO NOPT NOTI ATCO|Unknown|101-Mechanical|Locking Mechanism|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Service
Q3|7101172|06/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM no reply when polling|ATCO NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|P6000100953|05/08/2013|priority 3 |Q3|Unknown|Unknown|Wrong Signature curves|ATCO NOCO NOTE NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|100037966|05/07/2006|priority 3 |Q3|Unknown|Unknown|PRD-0000025022 Needs Updating|NOCO NOTE ATCO|SCM -XT comm  procedure incorrect|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q1|3812476|11/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 1 Norne B-2H clogged ret. checkvalve|NOTI ATCO NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
Q3|7103233|15/09/2000|priority 3 |Q3|Unknown|Unknown|Customer comments to Manufact. Data Book|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
Q3|7102643|Unknown|priority 1 |Q3|Unknown|Unknown|Åsg SCM 10  Hyd leak line 17  Well I-4H|NOPT NOCO NOTI ATCO|Pressure Transducer top blown off|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Leakage
ZF|P7000039672|01/04/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOTE NOCO ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000037215|05/05/2011|priority 3 |Q3|ENGIE|NORTH SEA|Unit still in KOS2 but is in Kongsberg|ATCO NOTE NOPT NOCO|Part listed as located in wrong place|FMC Other Defect |Part Lost|SS - Controls - Electric Products|Other Electric Products|Projects Related|Documentation error
ZF|P6000104111|09/03/2018|priority 1 |Q3|Unknown|Unknown|Child QN on P21-SCM|NOTE NOCO ATCO|Operator error|TEST |Damaged During Testing|Object Types to Eng Matl CLASS|scm_mkIII|FMC Test |Damaged during testing
ZF|P6000102554|25/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7101463|14/12/2000|priority Unknown|Q3|Unknown|Unknown|MEG # 10 SCM Refurbishment.|NOTI ATCO NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000073687|26/06/2012|priority 3 |Q3|Unknown|Unknown|HC6 coupler damaged|NOPT ATCO NOTE NOCO|HC6 coupler damaged|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Test |Damaged during testing
ZF|100017278|08/01/2015|priority 3 |Q3|Unknown|Unknown|SCM retrieved not maintain acc. to stand|ATCO NOCO NOTE NOPT|Unknown|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000016420|19/05/2011|priority 1 |Q3|PETROBRAS|Unknown|Falha PT Interno do SCM.|NOCO NOTE ATCO NOPT|Wiring error|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100068622|28/07/2016|priority 3 |Q3|Unknown|Unknown|Not able to perform WGM/MFM test in HFT|ATCO NOCO NOPT NOTE|No available CPI test equipment.|Test Related |OBS-Missed Operation|SS - Controls -SCM el/opt components|Other el/opt components|FMC Test |Tooling
ZD|100052231|13/02/2014|priority 3 |Q2|Unknown|Unknown|Damage to outer can’s EC ports|ATCO NOTE NOCO NOPT|Unknown|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|P6000103208|20/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extended test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000108542|27/12/2016|priority 3 |Q3|Unknown|Unknown|RIT scope unable to be fully performed.|ATCO NOTE NOCO NOPT|Waiver for MPFM RIT Test|Change/Deviation Request |Process substitution request|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|P7000016420|27/09/2011|priority 1 |Q3|Unknown|Unknown|Base plate com problema dimensional|NOTE ATCO NOPT NOCO|USILIDER - BASE PLATE|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
ZF|P6000122626|03/03/2016|priority 3 |Q3|Unknown|Unknown|Voltage reading outside acceptance crit.|NOTE NOCO NOPT|Creiteria readings not acc to procedure|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Procedure error
ZD|3787101|25/09/2009|priority 3 |Q2|Unknown|Unknown|External leakage control valve|NOTE NOCO ATCO NOPT|Holes for namepl drilled into hydr. line|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Vendor related |Operator Error
ZF|100048038|29/03/2007|priority 2 |Q3|AGBAMI|Unknown|Trafo problems on Agbami S/N 24|NOTE NOPT NOCO ATCO|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P7000024900|18/10/2013|priority 1 |Q3|Unknown|Unknown|Oxidation on the El can's screws|ATCO NOTE NOPT NOCO|PO 47612315-4|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|7104075|24/06/2005|priority 3 |Q3|SHELL|GOM|SCM EXTENSION ROD|NOTE NOCO ATCO NOPT|Coating not applied per drawing|Coating |Coating not applied|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Do Not Use
Q3|100017305|29/11/2002|priority Unknown|Q3|Unknown|Unknown|No communication XT - SCM 03 SEM B|NOPT NOTI ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7101463|21/01/2011|priority 2 |Q3|Unknown|Unknown|Missing Sign offs|NOTE ATCO NOPT NOCO|Missing Sign Offs|Documentation |Procedure / Process Error|SS - Controls - Topside Products|Subsea Control Unit (SCU)|Intercompany|FMC Houston
ZF|P7000039672|23/08/2013|priority 1 |Q3|Unknown|Unknown|MARCAÇÃO DE FILTRO NÃO CONFORME|NOTE ATCO NOCO NOPT|134871 - Pall do Brasil Ltda|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Specification not followed
ZF|P6000088604|18/12/2012|priority 3 |Q3|Unknown|Unknown|Can bus 1 PT/TT3-A Never detected|NOPT NOTE NOCO|Opr. mistake during wiring of SCM|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|7104075|24/10/2006|priority 1 |Q1|SHELL|GOM|Manatee A2 SCM09 LP2 Leak at COVLP|NOPT NOCO NOTE|Assembly & Test error FMC|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Assy |Operator Error
ZF|P6000074156|06/03/2012|priority 3 |Q3|Unknown|Unknown|CVLP 11 not corrosponding correct|NOTE NOCO NOPT|Operator error  during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZE|P6000055605|22/04/2014|priority 3 |Q3|Unknown|Unknown|Wrong pressure on PT when operating CVHP|NOCO ATCO NOTE|Operator didn`t pay sufficient attention|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P7000039672|20/08/2013|priority 1 |Q3|Unknown|Unknown|Falta do corpo da calha|NOPT ATCO NOTE NOCO|117094 FMC KONGSBERG SUBSEA AS|FMC Other Defect |Part Lost|SS - Controls -SCM  hyd/mech components|Other mechanical components|Intercompany|FMC Kongsberg
ZF|P6000088751|06/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SEM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000069056|16/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|SCM need to be retagged|NOPT ATCO NOTE NOCO|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|7101172|12/02/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 214-Gullfaks leakage I-3H|NOTE NOCO|Wear and tear to valves during operation|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Lack of Maintenance
ZF|7101463|26/07/2005|priority 3 |Q3|MOBIL EG|Unknown|SEM FAIL HELIUM LEAK TEST|NOCO NOTE NOPT ATCO|SEM FAIL HELIUM LEAK TEST|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100056443|26/10/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|Wrong Clock frequency|NOTE NOCO|Vendor recommended TRITON update|Change/Deviation Request |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Unknown
ZF|P6000069056|22/08/2011|priority 3 |Q3|STATOIL|NORTH SEA|Itemliste/bom stemmer ikke med merking|NOPT NOTE NOCO|BOM configuration item numbering|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |QN Cancelled
ZF|7105130|26/11/2006|priority 1 |Q3|TOTAL|Unknown|no communication with SCM|NOTE NOCO ATCO NOPT|customer's error when powering it up|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|7104670|21/10/2014|priority 2 |Q3|Unknown|Unknown|Concession_FSM Test in HFT not performed|ATCO NOTE NOPT NOCO|Tets equipment to be delivered as CPI|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
Q2|7101401|23/03/2000|priority Unknown|Q2|Unknown|Unknown|Missing termination resistors in modem|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Refurbishment  Bytte av trykktransdusere|NOTE NOPT NOCO ATCO|Unknown|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|100037428|24/04/2007|priority 3 |Q3|TOTAL|WEST AFRICA|HFT procedure needs update|NOCO ATCO NOTE|Unknown|Documentation |Incorrect user documentation (customer)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Manufacturing Engineer Erorr
Q3|100020278|18/11/2002|priority 3 |Q3|EXXONMOBIL|Unknown|SCM CVs are leaking after PT Cycle test|NOTI NOCO NOPT ATCO|Refer to QN200013753 for cause|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Leakage
Q3|7105128|08/01/2001|priority Unknown|Q3|Unknown|Unknown|SCM P 01|NOCO ATCO NOTI NOPT|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Dimension
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrade Marlim SCM 07-ALFA to 07-GAMA|ATCO NOCO NOTI NOPT|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|P6000028371|02/08/2011|priority 3 |Q3|SHELL|GOM|Contaminated Silicone in SCM|NOTE ATCO NOCO NOPT|Contaminated Silicone in SCM|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Improper handling
ZF|P6000042970|19/10/2010|priority 2 |Q3|TOTAL|Unknown|Material not delivered to plant|NOCO NOTE NOPT|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|P6000121268|16/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|ATCO NOTE NOCO NOPT|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|7104075|05/04/2005|priority 2 |Q3|SHELL|GOM|Clarify SCM Lab document|NOPT NOTE ATCO NOCO|SCM Lab document not complete|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100016711|12/12/2003|priority 3 |Q3|BP|GOM|Failed in pressure test|NOCO ATCO NOTE NOPT|SCM over-pressurised or plug not torqued|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Assembly/Test related|Assembly/Test error
ZF|100017305|23/04/2003|priority 2 |Q3|STATOIL|Unknown|Possible Silicon polution in Brayco oil|ATCO NOTI NOPT NOCO|Unknown|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Assembly/Test related|Assembly/Test error
ZF|P6000069056|07/04/2015|priority 4 |Q3|Unknown|Unknown|"Deviation from ""no dead end"" principle"|NOCO NOTE ATCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|P6000050867|16/07/2010|priority 1 |Q3|PETROBRAS|Unknown|DAS loss of communication|ATCO NOTE NOCO|DAS loss of communication|FMC Other Defect |Functional|SS - Controls - Test and Transportation|Communication Test Unit (CTU)|Intercompany|FMC Kongsberg
ZE|100046112|04/05/2013|priority 2 |Q3|Unknown|Unknown|POG - SCM Fault|NOCO ATCO NOTE|POG - SCM Fault|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000055605|10/10/2011|priority 3 |Q3|SHELL|GOM|Hyperbaric procedure must be updated|NOPT NOTE ATCO NOCO|Procedure updated acc. to marups|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100020562|02/12/2009|priority 1 |Q1|BP|GOM|Bad reading on NOVA DHPT|NOTE NOCO ATCO|Bad reading on NOVA DHPT|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P6000042969|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|Rosa 301 SEM A failure|NOTE NOCO NOPT|Unknown|FMC Other Defect |Unknown|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Unknown
ZF|100031223|03/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|THE SCM IS LEAK|NOTE ATCO NOCO NOPT|Plug not tightened.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Compensators|FMC Assembly/Test related|Operator error
ZF|P6000088626|28/11/2014|priority Unknown|Q3|Unknown|Unknown|P6000121475 Wrong measurment.|NOPT NOCO NOTE|Wronly bent  DWG not followed|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Fabrication Shop Personnel |Operator error
ZF|100052701|13/04/2010|priority 4 |Q3|STATOIL|NORTH SEA|F&D SCM drained.marked whit n/a|ATCO NOCO NOTE|Missing marking on silicone level|Documentation |Incorrect Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZF|100050519|21/10/2013|priority 1 |Q3|Unknown|Unknown|SCM RELIEVING AT 5 PSI|NOPT NOTE ATCO NOCO|SCM RELIEVING AT 5 PSI|Procurement |Vendor did not complete required work|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Equipment Malfunction
ZF|100037967|22/01/2008|priority 1 |Q3|BP|Unknown|SEM A FAILURE ON MCM S1|NOTE NOCO NOPT|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Packaging & Storage
ZE|P7000008275|05/04/2013|priority 2 |Q3|Unknown|Unknown|RCA - empenamento dos stabs Outer Can|ATCO NOCO NOTE|Interferência entre ferramenta e peça|Unknown|Unknown|FKS Quality system issues|Product Realization|Variance|Handle Tooling Issue
ZE|100046112|04/05/2013|priority 2 |Q3|Unknown|Unknown|Angel - SCM Issue|NOCO NOTE ATCO|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|Non functioning PT|NOCO ATCO NOTE NOPT|Non functioning PT|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 01|ATCO NOPT NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000000897|10/02/2012|priority 1 |Q3|Unknown|Unknown|Function  CVHP53 and CVHP54 are crossed|NOPT NOCO NOTE ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|SCM11 connector damaged|NOTE NOCO ATCO|Unknown|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Other causes/damage |QN Cancelled
ZF|P6000063531|20/04/2017|priority 3 |Q3|Unknown|Unknown|ALD test failed during mobilization|NOTE NOPT NOCO ATCO|Test equipment verified OK|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|P7000016420|09/11/2011|priority 1 |Q3|Unknown|Unknown|Rosca do conector travada|NOPT NOTE NOCO ATCO|ODI - Conector eletrico de base|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Assembly error
ZB|P6000065886|04/09/2013|priority 1 |Q1|Unknown|Unknown|Marulk / Norne Claim 224 Leakage on SCM|NOCO NOTE ATCO|ECN 6130063  - design improvement|Damage |Wear & Tear|Customer Compliant|Unsatisfactory Customer Satisfaction|FMC Engineering related |Continuous Improvement
ZF|P7000024900|08/08/2013|priority 1 |Q3|Unknown|Unknown|Check Valve out of Acceptance Criteria|NOCO NOPT ATCO NOTE|1242 - HTS Maskinteknikk AS|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZF|100037428|17/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|MPFM outside acceptance criteria|ATCO NOPT NOCO NOTE|Wrong requirements in procedure|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZB|100020562|17/03/2008|priority 1 |Q1|BP|GOM|PT on CIT2 is giving false reading|NOCO ATCO NOTE NOPT|Pressure Transducer Failure|FMC Other Defect |Functional|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
Q3|7103233|Unknown|priority 4 |Q3|Unknown|Unknown|DSP-0010466 at rev0 (issued for review)|NOPT NOTI ATCO NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
ZF|100017305|28/04/2003|priority Unknown|Q3|STATOIL|Unknown|Feil transport skid brukt ved transport|NOPT NOCO NOTE ATCO|feil  transp. skid|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Other causes|Logist.-Handling/Packing/Shipping error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOPT NOCO NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000088751|06/02/2013|priority 3 |Q3|Unknown|Unknown|No communication with  DHI212.2 Sem A|NOTE NOPT ATCO NOCO|Eng.err.  wrong length on ribbon cables|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Engineering related |Specification error
ZF|P6000055605|01/09/2011|priority 3 |Q3|SHELL|GOM|PT18 don`t work|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
Q3|7102643|20/09/2000|priority 3 |Q3|Unknown|Unknown|SCM leaks offshore  flushing pipe bent|NOPT NOTI ATCO NOCO|Check valvefitting damaged when handling|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Viking Poseidon|Initial/Direct product problem|Dimension
Q3|3812476|11/01/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM leaks via return line to sea (E3-AH)|NOTI NOPT NOCO ATCO|LP accumulator leak/O-ring replaced|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Leakage
ZF|100055762|22/08/2007|priority 3 |Q3|Unknown|Unknown|Bad threads on  vacum plug|ATCO NOPT NOTE NOCO|xylan coating on threads in baseplate|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 10|NOPT NOTE ATCO NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100037229|29/04/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Pressure drop in the hyperbaric|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Function|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Test |Tooling
ZF|P7000000897|14/09/2011|priority 2 |Q3|SHELL|Unknown|Marcação Incorreta|NOPT NOTE ATCO NOCO|FMC BRAZIL|Marking |No Marking|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |Cause not found
ZE|P6000088614|07/05/2018|priority 3 |Q3|Unknown|Unknown|SCM  Improvement Propossal - HFT60078748|NOTE ATCO NOCO|Update of procedure.|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Causes for Improvement|Documentation
ZF|P6000098616|27/06/2013|priority 2 |Q3|Unknown|Unknown|HS CAN bus grounding error on CPU card|ATCO NOPT NOCO NOTE|ISO GND missed in wiring specification|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|100037965|15/01/2008|priority 1 |Q3|BP|Unknown|screw M10 & larger missing batch number|NOCO NOPT NOTE| use as is with batch certificates|Documentation |Incorrect Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of strainer|NOTE ATCO NOCO NOPT|Conflict between strainer and SCMMB|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000039672|12/08/2014|priority 1 |Q3|Unknown|Unknown|Parafuso com o comprimento maior|NOTE NOPT ATCO NOCO|124086 PARNOX IND E COM DE ARTIGOS IND L|Assembly Related |OBS-Interface issue|Common/Misc - Fasteners - Metric|Screw|Vendor related |Final Inspection Error
ZB|7102969|04/02/2007|priority 4 |Q1|MOBIL EG|Unknown|Unable to communicate with Quantex DwnHl|NOTE NOCO ATCO|Unknown|Assembly/Test Related |Function|Subsea sensors (not in SCM)|Pressure Transmitter (PT)|FMC Engineering related |Engineering Error
ZF|100037427|19/05/2007|priority 3 |Q3|TOTAL|WEST AFRICA|leakage from LP1 & HP1 when LP2 press.|NOCO NOTE NOPT|No failure|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P7000039672|10/09/2013|priority 1 |Q3|Unknown|Unknown|Vazamento na adapter plate de LP PS#13|NOCO ATCO NOTE NOPT|123643 - BOSCH REXROTH  LTDA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZD|100020278|27/05/2011|priority 3 |Q2|EXXONMOBIL|Unknown|no revision letter on part|NOPT NOTE ATCO NOCO|no revision letter on part|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
Q3|100017305|08/11/2002|priority 2 |Q3|Unknown|Unknown|SCM water in return lines|NOCO NOTI NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100020562|22/09/2008|priority 2 |Q1|BP|GOM|Nova gauge lost power|NOCO NOTE NOPT|Nova gauge lost power|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|DHI PCBs|Vendor related |Equipment Malfunction
ZF|P6000081371|14/06/2012|priority 3 |Q3|SHALLOW WATER SCM|Unknown|problem assemle the name plate|NOTE NOPT ATCO NOCO|Problems attaching Nameplate on OC|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Specification error
Q3|7101172|06/03/2001|priority 3 |Q3|Unknown|Unknown|SCM  internal leakage on LP line (F-4H)|NOTI NOPT ATCO NOCO|Contol Valve leaking|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZF|P6000055605|07/03/2013|priority 3 |Q3|Unknown|Unknown|FSK to QAM procedure needs revision.|NOTE ATCO NOCO|FSK to QAM procedure needs revision.|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
Q3|7102643|Unknown|priority 3 |Q3|Unknown|Unknown|SCM not contactable by address nr.|NOPT NOCO ATCO NOTI|SEM address correct  no fault found|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - offshore/field|Transocean Searcher|Problem causes  defect causes|Service
ZD|P6000055605|16/02/2015|priority 3 |Q2|Unknown|Unknown|Damage/Shell/SCM/Lost Communication|NOTE ATCO NOCO NOPT|25AF52 SCM Lost of Communication|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|P6000145982|25/07/2018|priority 2 |Q3|Unknown|Unknown|SEM  Damaged MRM/LNCT Card|NOPT ATCO NOTE NOCO|Needs to change MRM/LNCT Card|TEST |Damaged During Testing|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Damaged during testing
Q3|100020562|30/08/2002|priority 2 |Q3|Unknown|Unknown|BP IWOCS & TH SCMs  same SEM address|NOCO ATCO NOTI NOPT|Not picked up during contract review|103-Electrical|SEM El.Rack|Ext. loc. - KOS Houston|Work Shop|Root cause Engineering|Design Specification error
ZD|P6000042968|20/07/2009|priority 1 |Q2|Unknown|Unknown|certification|ATCO NOTE NOCO|VL - Missing Full Cert Pack|Documentation |Missing Certificates / Records|SS - Compl. & W.Over - XT - General|Tree Assembly|Vendor related |Operator Error
ZF|7104033|07/05/2007|priority 2 |Q3|STATOIL|NORTH SEA|Silicone leak in SCM -Compensator broken|NOTE NOCO|Customer resp./storage error|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Intervention - Running Tool|SCM Running Tool|Other external causes |Customer Error/responsibility
Q3|7105128|09/01/2002|priority 3 |Q3|Unknown|Unknown|SCM 06 Girassol PT HP Supp. unstabile|NOPT NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Girassol FPSO|Initial/Direct product problem|Function
ZF|P7000016420|22/10/2010|priority 1 |Q3|Unknown|Unknown|Revestimentos em desacordo com DBI|NOPT NOTE ATCO NOCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZD|P6000069820|07/07/2011|priority 2 |Q2|CONOCOPHILLIPS|Unknown|(SS) Coating  Peel-Off  & Scratches|NOTE NOPT ATCO NOCO|Coating  Peel-Off  due to Handling|Coating/Plating |Coating defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Damage during transport
ZB|100050519|20/10/2009|priority 2 |Q1|MOHO BILONDO|Unknown|Sensor communication failure|NOTE ATCO NOCO|Software error in SCM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000016420|13/10/2011|priority 3 |Q3|Unknown|Unknown|Screws whithout Batch marking|ATCO NOTE NOCO NOPT|Batch number|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100038200|07/10/2010|priority 3 |Q3|SHELL|Unknown|Incomplete databook|ATCO NOCO NOPT NOTE|missing signoff and n/a section|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZB|P6000133916|28/11/2018|priority 3 |Q1|Unknown|Unknown|Touch up paint on SCM#12|NOCO ATCO NOTE NOPT|Unknown|Coating/Plating |Coating defect|Object Types to Eng Matl CLASS|scm_mkIIE|Documentation Requirement |Process step not followed / detected
Q3|100018600|28/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|B electronic don't switch off MFM power|NOPT ATCO NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100051269|23/11/2007|priority 3 |Q3|STATOIL|NORTH SEA|VGS B&B38 Mob. SCM  11 fail during HFT|ATCO NOTE NOCO NOPT|Operator error|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|100048038|12/04/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|LP pressure changes AGB SN 21|NOTE ATCO NOPT NOCO|New requirements from customer|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #15 Wiring|ATCO NOTE NOCO NOPT|BPTH SKOFLO SCM SN #15 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100031223|06/05/2010|priority 3 |Q3|Unknown|Unknown|Error in drawing.|ATCO NOCO NOPT NOTE|Wrong Screw used for HP  valve / adapter|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|P6000105542|10/12/2014|priority 2 |Q3|Unknown|Unknown|SCM manifold block failure - SN20|NOTE NOCO|Wrong welding pin defined for man. block|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZF|P6000074156|10/02/2012|priority 3 |Q3|Unknown|Unknown|Tubing not mounted correct|NOTE NOPT ATCO NOCO|Parts assembled incorretly in workshop.|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Operator Error
ZF|P6000105542|02/06/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|ATCO NOPT NOCO NOTE|Concession request.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Customer Error
ZF|P7000039672|10/10/2013|priority 1 |Q3|Unknown|Unknown|Tubo danificado durante montagem|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Assy |Damaged during assembly
ZF|100027228|11/04/2003|priority 3 |Q3|Unknown|Unknown|"FAIL DURING DHI 109 ""PSM"""|NOCO NOPT NOTI|Unknown|Assembly / Test related |Function|Software  FKS provided|SEM|FMC Engineering related|Miscellaneous Product Design errors
ZF|100030542|04/04/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|Unknown|COM test on SCM 24|NOCO NOPT NOTE|Wrong accept. criteria in PRD-0000022442|Documentation |Incorrect user documentation (customer)|SS - Controls - Sensors|SCM Flowmeter|FMC Engineering related |Engineering Error
Q3|7104020|Unknown|priority 3 |Q3|Unknown|Unknown|Silicone oil is not sampled in procedure|NOPT ATCO NOTI NOCO|Check missing in procedure|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P7000000897|01/03/2011|priority 1 |Q3|Unknown|Unknown|PT4 fail.|NOTE ATCO NOCO NOPT|It was not possible read pressure values|FMC Other Defect |Functional|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P7000000897|20/12/2010|priority 1 |Q3|Unknown|Unknown|Vazamento|NOCO NOPT NOTE|Unknown|Test Related |OBS-Leakage (gas)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|7102969|19/05/2006|priority 3 |Q3|EXXONMOBIL|Unknown|INTERNAL PT OUT OF RANGE|NOPT NOCO NOTE ATCO|INTERNAL PT OUT OF RANGE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|7103233|06/03/2000|priority Unknown|Q3|Unknown|Unknown|Testing not done to CSA requirement|NOTI ATCO NOCO NOPT|TPR-0010791 not updated to requirements|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. El.lab|Initial/Direct product problem|Documentation
ZB|100018820|25/04/2003|priority 3 |Q1|EXXONMOBIL|NORTH SEA|SCM 1 Sigyn PT Func. MIV unstable|NOTE NOCO NOPT|Unknown|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Purchasing related|Miscellaneous
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 2 RCA Actions_2 from RPT10033107|NOPT NOTE NOCO ATCO|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of Resources
Q3|7104670|10/05/2001|priority 3 |Q3|Unknown|Unknown|SCM communication problems|NOPT NOCO ATCO NOTI|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
ZD|P6000069820|20/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PART NUMBER|NOCO NOPT ATCO NOTE|INCORRECT PART NUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000069056|29/09/2011|priority 2 |Q3|STATOIL|NORTH SEA|Missing batch-management on 200017100|NOTE NOCO|Wrong ECN class used.|Design |DBI Error|Common/Misc - Fasteners - Metric|Screw|FMC Engineering related |DBI error
ZF|100035119|25/11/2015|priority 2 |Q3|Unknown|Unknown|Company request to not installe DHI|ATCO NOCO NOTE NOPT|Unknown|Project|Project Requested Unfinished shipment|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Other external causes |Customer Error/responsibility
Q1|7101172|05/03/2002|priority 3 |Q1|STATOIL|NORTH SEA|Silicone oil leaking between HXT and SCM|NOCO NOPT NOTI ATCO|Not yet known  still subsea|Unknown|Unknown|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Leakage
Q3|7105128|18/11/1999|priority 1 |Q3|Unknown|Unknown|SCM P 04|NOTI ATCO NOPT NOCO|Compensator was not installed|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Tank test|Initial/Direct product problem|Leakage
ZB|P1000004979|17/01/2008|priority 3 |Q1|BP|Unknown|SEM B sensors reading too low|NOPT NOTE NOCO|SEM B sensors reading too low|Test Related |OBS-Function|Software  FKS provided|SEM|FMC Test |Missed operation
ZF|7104033|29/08/2016|priority 3 |Q3|Unknown|Unknown|Too high voltage used on SCM (388 VAC)|NOCO ATCO NOTE|Error on name plate.|TEST |Damaged During Testing|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Marking |Incorrect Marking
ZF|P7000039672|18/12/2014|priority 1 |Q3|Unknown|Unknown|Vazamento nos o-rings dos stabs|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Test |Damaged during testing
ZF|P6000068902|02/12/2011|priority 3 |Q3|Unknown|Unknown|No reading from PT 11|NOCO ATCO NOPT NOTE|W03 replaced as a  precautionary measure|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Test |Missed operation
ZF|P6000093498|06/06/2014|priority 3 |Q3|Unknown|Unknown|SUPS failing during load test|NOPT ATCO NOCO NOTE|Ref ZD QN 200386252|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZF|100037966|20/09/2006|priority 3 |Q3|BP|Unknown|SCM being returned for flowmeter problem|NOTE ATCO NOCO NOPT|wiring error during assy|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|100020278|07/03/2003|priority 3 |Q3|Unknown|Unknown|Various SCM drawings need updating|NOCO ATCO NOTI NOPT|FKS drawing errors|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|User Documentation error
ZF|100037428|08/09/2005|priority 3 |Q3|TOTAL|WEST AFRICA|Bad finish on outercan.Quality issue.|NOPT ATCO NOTE NOCO|RAL code allows different colour shades|Coating |Coating Defects|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of strainer|NOTE NOCO NOPT ATCO|Conflict between strainer and SCMMB|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZB|100037965|05/04/2016|priority 2 |Q1|Unknown|Unknown|ETU Setup file loading configure setup|ATCO NOPT NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Lack of training
ZF|P6000074156|14/03/2012|priority 2 |Q3|Unknown|Unknown|ATS-Missing Documentation|NOCO ATCO NOTE|ATS documentation missing|Documentation |Missing Certificates / Records|Vendor Quality system issue|Quality Management System|FMC Other causes/damage |QN Cancelled
Q3|7104033|20/01/2000|priority 3 |Q3|STATOIL|NORTH SEA|Damage may occur due to wrong coupling|NOPT NOTI ATCO NOCO|Mulighet for feilkobling av Connector`s|101-Mechanical|Outer Can|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Marking
Q3|7104670|Unknown|priority 4 |Q3|Unknown|Unknown|Bytte av poppet i Hydr. koplere.|NOPT ATCO NOTI NOCO|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|100015538|29/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|Piping (HP & LP) on SCM|NOCO ATCO NOPT NOTE|URT SCM interface modified|Service/maintenance related|Unknown|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Operation/maintenance related |Maintenance error
Q3|7102643|22/11/2000|priority 3 |Q3|ÅSGARD|Unknown|HP PT readings fluctuate  Well M-3H|NOCO NOPT NOTI ATCO|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|100034440|08/08/2008|priority 1 |Q3|HOUSTON STOCKING MK IV|Unknown|Possibly Damaged|ATCO NOCO NOTE NOPT|Possibly Damaged|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage during transport
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|ATCO NOCO NOTE NOPT|Dial caliper coupler measurements|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
Q3|7104670|26/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|Tilbakekalt modul (SIO-kort)|NOCO ATCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P7000008275|30/06/2014|priority 1 |Q3|Unknown|Unknown|Finalização do teste hiperbárico TBU#1|NOCO NOPT ATCO NOTE|MMR Rio|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
Q1|7103233|10/08/2000|priority 3 |Q1|Unknown|Unknown|SCM CIDV leaking? Retested - no leak|NOCO NOTI NOPT|No fault|102-Hydraulic|Chemical Control Valves|Ext. Loc. - St.Johns (Canada)|Goods Receipt|Initial/Direct product problem|Leakage
Q3|7104075|14/11/2000|priority Unknown|Q3|Unknown|Unknown|silicon fluid found inside of SEM cans|NOCO ATCO NOTI NOPT|Unknown|103-Electrical|SEM Baseplate/Penetr. & RCM Penetrators|Ext. loc. - KOS Houston|Work Shop|Initial/Direct product problem|Leakage
ZB|100020278|22/04/2008|priority 2 |Q1|EXXONMOBIL|Unknown|Well SS-3 # High SCM Return Line Press.|NOCO NOTE NOPT ATCO|Well SS-3 # High SCM Return Line Press.|Test Related |OBS-Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Cause not found
ZF|P7000016420|20/05/2011|priority 1 |Q3|Unknown|Unknown|Medições SEM A 230v Supply|ATCO NOPT NOCO NOTE|Tensão fora criterio|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Engineering related |Specification error
ZF|P6000065528|20/04/2011|priority 3 |Q3|Unknown|Unknown|Not possible to connect the outer can|NOCO NOPT NOTE|Human error in wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100052231|01/02/2007|priority 1 |Q3|CHEVRON|GOM|An abnormal leakage on SCM|NOTE NOCO NOPT ATCO|failure caused by unstable check valves|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|7100320|17/12/2001|priority 3 |Q3|PETROBRAS|Unknown|SCM 8 Hercules AI/AIDO board failure|NOTI NOCO ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Function
ZF|100026567|11/09/2003|priority 2 |Q3|Unknown|Unknown|Updating of Assy DWG VIGDIS SCM|ATCO NOPT NOCO NOTE|Feil på tegning|Assembly / Test related |Marking|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Engineering related|Miscellaneous Product Design errors
ZF|7104075|29/01/2008|priority 2 |Q3|Unknown|Unknown|SEM A not reading values|NOTE NOPT NOCO ATCO|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q2|7104670|12/09/2000|priority 2 |Q2|Unknown|Unknown|Lock rings on tronic connector to wide|NOCO NOPT NOTE|Unknown|202-Electrical/Sensor equipment|Electrical Pin Connetors|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
Q3|100018600|06/02/2003|priority Unknown|Q3|PETROBRAS|Unknown|No contact w/EC14 when SCM engaged on MB|NOTE NOCO ATCO NOPT|SIT proc. for SCM install. not followed|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Unknown|Unknown
ZF|P6000068902|08/12/2015|priority 3 |Q3|Unknown|Unknown|Transport defect on coating|NOPT NOCO NOTE ATCO|Transport damage on coating|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Coating Defect
ZF|P7000024191|19/02/2013|priority 1 |Q3|Unknown|Unknown|SRT - GLOBAL #16 CAN BUS AND SERIAL LINE|NOTE ATCO NOPT NOCO|Lab Test Box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZB|7101172|14/09/2006|priority 4 |Q1|STATOIL|NORTH SEA|Failure on valve response on system II|NOPT NOTE NOCO|AI-card failure on SEM-A|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider på ventiler.|NOCO NOTI ATCO NOPT|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
Q3|7104075|Unknown|priority 3 |Q3|Unknown|Unknown|SHE SCM 02|ATCO NOCO NOTI NOPT|To be checked in workshop|101-Mechanical|Outer Can|Defect locations - onshore|Customer goods receipt|Initial/Direct product problem|Dimension
ZB|100017278|08/01/2010|priority 3 |Q1|STATOIL|NORTH SEA|F&D 10 Åsg  To many couplers on SCM|ATCO NOCO NOTE NOPT|Too many couplers on SCM|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZE|P6000121393|05/10/2015|priority 2 |Q3|Unknown|Unknown|HC1 LEAKING|ATCO NOCO NOTE|Leakage on coupler|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Products|Coupler|Variance|Capture Mistake
ZF|P6000065886|15/12/2010|priority 2 |Q3|Unknown|Unknown|Remove PN: DP-48-1903|NOPT NOCO NOTE|BOM error|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Engineering related |DBI error
ZD|P6000125392|04/05/2016|priority 1 |Q2|Unknown|Unknown|Quality Issue|NOCO ATCO NOTE|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZE|P6000074156|12/04/2017|priority 3 |Q3|SHELL|Unknown|Shell  SCM  Fluid Leaks|ATCO NOTE NOCO|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Tooling Malfunction
ZB|P6000080343|27/09/2012|priority 3 |Q1|Unknown|Unknown|Warranty Claim SCM MKll Jubilee phase 1A|NOTE NOCO ATCO|FMC Dunfirmline produced incorrectly|Machining Related |OBS-Position Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOPT ATCO NOTE NOCO|PSM not followed  short mob time|Assembly/Test Related |Do Not Use|FKS Quality system issues|Resource Management|FMC Assy |Missing Operation
Q3|7106268|11/02/2002|priority 3 |Q3|TOTAL|Unknown|MIV PT is malfunctioning during test|NOCO NOTI NOPT|PT defective|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Pride Angola|Initial/Direct product problem|Function
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|Unknown|Possible chips inside the HP-Config Plug|NOTE NOCO NOPT ATCO|Parts not cleaned by supplier.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZE|P6000088626|17/08/2016|priority 3 |Q3|Unknown|Unknown|Torque tool (tt) interface on MCM and HC|NOTE NOCO ATCO|Top plates not acc to TT API 17D std|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|Certification |Requirements not followed
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOPT NOTE NOCO ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000029772|13/08/2009|priority 3 |Q3|Unknown|Unknown|SRM marking error|ATCO NOCO NOPT NOTE|GA drawing error|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZD|P6000042968|02/02/2010|priority 1 |Q2|Unknown|Unknown|certification|ATCO NOTE NOCO|VL - Cert Issue|Documentation |Missing Certificates / Records|Common/Misc - Fittings|Other|Intercompany|FMC Kongsberg
ZF|100017278|28/08/2006|priority 3 |Q3|STATOIL|NORTH SEA|Error in config file.|NOPT NOTE NOCO|QN provided by mistake|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|7103479|29/08/2005|priority 3 |Q3|SHELL|Unknown|BOLTS TO EL. BRACKET IS BROKEN|NOTE NOCO ATCO NOPT|Too high torque during untorque from XT|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000068918|04/01/2012|priority 3 |Q3|TOTAL|Unknown|Wrong twisted pair on EC2|NOCO NOTE ATCO NOPT|Operator did not follow the procedure|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000077638|08/01/2013|priority 3 |Q3|Unknown|Unknown|Too bad space in SEM|NOTE NOCO NOPT|Human mistake in SEM configuring|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|P6000043714|08/04/2009|priority 1 |Q1|PETROBRAS|GOM|Communication Problem with SMPFM|NOTE ATCO NOPT NOCO|Communication Problem with SMPFM|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor related |Equipment Malfunction
ZF|P7000024191|11/05/2012|priority 1 |Q3|Unknown|Unknown|Testado em desacordo com o Procedimento|ATCO NOTE NOPT NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100020562|18/10/2004|priority 2 |Q3|BP|GOM|Water ingress in SCM from strainer assy?|NOCO NOPT NOTE ATCO|Nut not properly torqued.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Compensators|FMC Assembly/Test related|Assembly/Test error
ZB|P6000055605|04/02/2016|priority 3 |Q1|Unknown|Unknown|MRB review comments from Shell|NOTE NOCO NOPT ATCO|documentation errors in MRB|Documentation |Incorrect user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|Unknown|SCM bladder ruptured 18h after top-up|ATCO NOCO NOTE|Unqualified Vendor used|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Unqualified Vendor used
ZF|100037428|12/04/2016|priority 2 |Q3|Unknown|Unknown|Too low output voltage from DHI boards|NOPT NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 06|ATCO NOTE NOCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000121393|22/05/2015|priority 3 |Q3|Unknown|Unknown|Too high voltage vrong way|NOCO NOTE NOPT ATCO|Wrong termination in hyperbaric test|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZB|7104075|17/01/2008|priority 2 |Q1|SHELL|GOM|EA5-SCM13-LineA|NOPT NOTE ATCO NOCO|EA5-SCM13-LineA|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor related |Equipment Malfunction
Q3|7104033|Unknown|priority Unknown|Q3|Unknown|Unknown|Unknown|NOTI ATCO NOPT NOCO|Document list was not updated.|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|100052701|11/09/2007|priority 3 |Q3|Unknown|Unknown|Bad soldering on CFG 600 boards|NOTE NOCO NOPT|Vendor wormanship & FMC design error|Assembly/Test Related |Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Fabrication error
ZF|P7000039672|12/05/2014|priority 1 |Q3|Unknown|Unknown|Espessura menor / Logo FMC vermelho|NOPT ATCO NOTE NOCO|123608 - ARTE COLLOR INDUSTRIA E COMERCI|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P6000058949|05/07/2010|priority 2 |Q3|STATOIL|NORTH SEA|Change hydraulic coupler|NOTE NOPT NOCO ATCO|Sharp edge on Male coupler   test equip.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
Q2|7102969|19/04/2002|priority 3 |Q2|EXXONMOBIL|Unknown|MEG SCM 24 Damaged in shipping|NOTE ATCO NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100017997|25/09/2012|priority 2 |Q3|Unknown|Unknown|GA dwg needs update to be useful for FI|NOTE NOPT ATCO NOCO|GA dwg needs more info|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 02|ATCO NOPT NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|100020278|04/11/2005|priority 3 |Q2|Unknown|Unknown|Missing Documentation|NOPT NOTE NOCO|Lost documentation|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Logist.-Handling/Packing/Shipping error
ZB|P6000064909|10/06/2016|priority 3 |Q1|Unknown|Unknown|Defect Not. 04 - SCM No.10|ATCO NOTE NOCO|cause unknown - no liabiliy for FMC|Electrical |Performance|FKS Quality system issues|Quality Management System|Electrical |Other- Specify in comments
ZF|100033987|02/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|THE OUTER CAN DONT FIT|NOCO NOPT NOTE ATCO|Design is too tolerance sensitive.|Assembly / Test related |Dimension (tolerance)|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Engineering related|Design Specification/Drawing error
ZB|100020278|23/11/2008|priority 2 |Q1|EXXONMOBIL|Unknown|08-MEGI-015: AIB Voltage Reference Error|NOPT NOTE NOCO|AIB Vol Ref Error|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|SCM 14 24Volt PS Manatee2|NOCO NOPT NOTE|SCM 14 24Volt PS Manatee2|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Power supply|Vendor related |Equipment Malfunction
ZB|100038200|16/05/2008|priority 3 |Q1|ANADARKO|Unknown|"RAM Error Warning On ""A ""Side"|NOTE NOCO|RAM Error Warning On A Side|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Special electronics.|Vendor related |Unknown
ZF|P6000068770|13/08/2012|priority 2 |Q3|Unknown|Unknown|Incorrect assembly of El. Connector EC 7|NOTE NOCO|Failure is on EC7 on EDP not SCM.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCMMB|El. Connector|FMC Other causes/damage |QN Cancelled
ZF|P7000000897|21/09/2010|priority 2 |Q3|Unknown|Unknown|dimensões não correspondem com DBI.|NOPT ATCO NOCO NOTE|FORNECEDOR NÃO IDENTIFICADO|Machining Related |OBS-Outside Diameter Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
Q1|100001156|12/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|DHPT GFC M-1H malfunct. (drop out)|NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks C|Initial/Direct product problem|Function
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOTE NOPT NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|NOCO DLFL ATCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P6000093501|09/01/2013|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100054943|14/02/2008|priority 3 |Q3|WOODSIDE|Unknown|Batch numbers missing|NOCO NOTE NOPT|Unknown|Documentation |Missing Certificates / Records|FKS Quality system issues|Product Realization|FMC Other causes |Logist.-Handling/Packing/Shipping error
Q3|7106268|17/10/2001|priority 3 |Q3|TOTAL|Unknown|SCM overpressurized (540 bar)|NOCO NOPT NOTI|Testing error|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Pride Angola|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|100018820|27/05/2003|priority 3 |Q3|EXXONMOBIL|NORTH SEA|SIGYN SCM1 A-3H HP-internal leak|NOPT NOTE NOCO ATCO|Wrong bolt used|Service/maintenance related|Unknown|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Design Specification/Drawing error
ZB|100017997|03/05/2010|priority 2 |Q1|BP|Unknown|Hydraulic leakage in SCM Silicone|NOTE ATCO NOPT NOCO|Hydraulic leakage in SCM Silicone|Test Related |OBS-Leakage (Fluid)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Cause not found
Q3|7101401|02/12/1999|priority 2 |Q3|PETROBRAS|Unknown|Upgrade Marlim SCM 02-ALFA to 02-OMEGA|NOPT ATCO NOTI NOCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
Q3|3794920|28/12/1999|priority 3 |Q3|Unknown|Unknown|Subsea control module|NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000042968|31/03/2009|priority 3 |Q3|TOTAL|WEST AFRICA|SW problems|NOPT NOCO NOTE|Unknown|FMC Other Defect |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Other external causes |Unknown
ZB|P6000080678|26/02/2016|priority 3 |Q1|Unknown|Unknown|WEL SCM  PSM not followed|NOTE NOPT ATCO NOCO|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Lack of training
ZF|100064910|09/12/2014|priority Unknown|Q3|Unknown|Unknown|Tubing too short (p4-p5)|NOCO NOTE NOPT ATCO|DWG error  corrected and released.|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |DWG Error
ZB|100017278|17/12/2007|priority 1 |Q1|STATOIL|NORTH SEA|Warranty claim 159 - SCM  hydr leakage|NOTE ATCO NOCO NOPT|Repair not according to requirements|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Operator error
ZD|P6000068912|29/09/2015|priority 3 |Q2|Unknown|Unknown|Missing item (SCM#17) on DN 82065442|ATCO NOTE NOCO|Missing Parts|FMC Other Defect |Part Lost|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q3|7102643|02/02/2000|priority Unknown|Q3|STATOIL|NORTH SEA|Åsg SCM 34  FAT results mix of procedure|NOTI ATCO NOPT NOCO|FAT procedure has not been updated|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Documentation
Q3|100017305|11/11/2002|priority 3 |Q3|STATOIL|Unknown|SCM communication problem  XT sensors|NOCO NOTI NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|Shell control module # 4|NOCO NOTI ATCO NOPT|See description|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Repair
ZB|7104075|17/01/2008|priority 2 |Q1|SHELL|GOM|SCSSVs Crossed & Reversed|NOTE NOPT NOCO|Unknown|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Wiring|Vendor related |Equipment Malfunction
ZF|P7000024191|20/09/2012|priority 1 |Q3|Unknown|Unknown|MG07 - Montagem do filtro invertido.|NOTE ATCO NOPT NOCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000084242|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7102643|06/12/1999|priority 3 |Q1|Unknown|Unknown|Subsea Control Module|NOPT NOTI ATCO NOCO|Communnication failure|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q3|7103233|Unknown|priority Unknown|Q3|Unknown|Unknown|El rack 'A' test results out of limits|NOTI NOPT ATCO NOCO|Unknown|103-Electrical|SEM El.Rack|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000107981|24/06/2014|priority 3 |Q3|Unknown|Unknown|To high current draw for MPFM simulator|NOCO NOTE ATCO NOPT|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
Q3|7100320|Unknown|priority Unknown|Q3|Unknown|Unknown|Oppgrader Hercules 11-GAMA til 11-OMEGA|NOPT NOTI NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000016420|17/01/2011|priority 1 |Q3|Unknown|Unknown|Adapter plate de retorno danificada.|ATCO NOPT NOTE NOCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|P7000001843|15/04/2011|priority 1 |Q3|Unknown|Unknown|Revestimento não conforme|NOPT NOTE NOCO ATCO|Pintura|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZB|7104670|22/04/2008|priority 1 |Q1|STATOIL|NORTH SEA|D5 SCM does not work|ATCO NOTE NOCO NOPT|MFM does not work|Not retrived gauarantee case|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Customer Error/responsibility
ZF|P7000001621|15/02/2013|priority 1 |Q3|Unknown|Unknown|PT's Fora do range Hérc.Ug 15|NOPT NOCO ATCO NOTE|Reparo de SCM|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Maintenance
ZF|100037427|12/08/2011|priority 3 |Q3|Unknown|Unknown|Fail in config|NOTE ATCO NOCO NOPT|Used wrong ETU version during test|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Test |Incorrect set up/testing
ZF|P6000064909|29/09/2011|priority 2 |Q3|TOTAL|NORTH SEA|Missing batch-management on 200017100|NOTE NOCO|Wrong ECN class used.|Design |DBI Error|Common/Misc - Fasteners - Metric|Screw|FMC Engineering related |DBI error
ZF|P6000074156|22/08/2013|priority 2 |Q3|Unknown|Unknown|(SS) Prelude - SCM Canbus Channel 6 Comm|ATCO NOCO NOTE NOPT|SCM Canbus Channel 6 Comm|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000091085|19/02/2013|priority 3 |Q3|Unknown|Unknown|Wrong drawing.Gas prechage port|NOTE NOPT NOCO|Gas port not used on this project|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZF|P6000108542|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extended test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7101172|24/02/2000|priority 4 |Q3|Unknown|Unknown|All SCMs to have hyd. flow restrictors|NOCO NOPT NOTI|Instructions from system engineering|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZB|100001156|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|Failure on AI card on SEMA  well L-3H|NOTE NOPT NOCO ATCO|AI card might be of batch with failure|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Do Not Use
ZF|100036936|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE|Unknown|FMC Other Defect |Functional|FKS Quality system issues|Resource Management|FMC Other causes/damage |Planning error
ZF|100020562|07/12/2010|priority 4 |Q3|BP|GOM|Concession request on error in document|NOTE ATCO NOCO NOPT|Error in QAP document|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|P6000039844|16/04/2018|priority 1 |Q1|Unknown|Unknown|Shell GK SCM#26 incoming issue|ATCO NOPT NOTE NOCO|Part received with damaged body in NJ|Damage |Damage during transport|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Other causes/damage |Damage during transport
Q3|7103233|04/04/2000|priority Unknown|Q3|Unknown|Unknown|SCM Outer Cans require paint touch up|NOPT NOCO NOTI|Minor handling damage|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Coating
Q1|7103234|19/06/2002|priority 3 |Q1|Unknown|Unknown|SCM flowmeter bolt broke when removing|NOCO NOPT NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100020562|26/02/2010|priority 2 |Q3|Unknown|Unknown|BPTH SmartTool V174 EFAT Punchlist Items|NOTE ATCO NOPT NOCO|BPTH SmartTool V174 EFAT Punchlist Items|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|100017305|02/03/2010|priority 3 |Q3|STATOIL|Unknown|HFT/mob of SCM should be updated|NOTE NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Service Related:|Improper job preparation
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #12 Wiring|NOTE NOPT NOCO ATCO|BPTH SKOFLO SCM SN #12 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZE|P6000074156|12/09/2012|priority 2 |Q3|Unknown|Unknown|Over Pressurization of SCM's Orange|NOTE ATCO NOPT NOCO|Unknown|Unknown|Unknown|SS - Controls -SCM Test Stand|Pressure Regulator|Causes for Improvement|Lack of training
ZF|100017278|06/04/2014|priority 2 |Q3|Unknown|Unknown|Company requested not perform overhaul|ATCO NOPT NOTE NOCO|Unknown|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000016420|28/01/2011|priority 2 |Q3|Unknown|Unknown|Diâmetro não conforme.|NOPT NOCO ATCO NOTE|Unknown|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Dirt found between CVs and solenoids|NOTE ATCO NOPT NOCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Cleanliness
ZF|100049392|19/09/2006|priority 3 |Q3|STATOIL|NORTH SEA|Installation of DIACS-SCM on SYGNA N-1.|NOCO NOTE ATCO|Unknown reason for failure|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Other external causes |Customer Error/responsibility
ZB|P6000064909|10/06/2016|priority 3 |Q1|Unknown|Unknown|Defect Not. 06 - SCM 6 LAGGAN L1Z|NOCO NOTE|cause unknown - no liabiliy for FMC|Electrical |Performance|FKS Quality system issues|Quality Management System|Electrical |Other- Specify in comments
ZF|7104033|08/11/2012|priority 3 |Q3|Unknown|Unknown|HFT missing towards P/N in SAP|ATCO NOTE NOCO|Delivery project not connected the doc.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q2|7103233|Unknown|priority 3 |Q2|Unknown|Unknown|The LP valves do not open at min pressur|NOCO ATCO NOTE NOPT|Testing method at 90 bar.|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
ZB|100020278|11/02/2008|priority 2 |Q1|EXXONMOBIL|Unknown|SCM 25 communication problem|NOCO ATCO NOPT NOTE|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P7000024191|25/01/2016|priority 3 |Q3|Unknown|Unknown|FALHA NA SEM B|NOPT DLFL NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000100953|30/01/2014|priority 3 |Q3|Unknown|Unknown|Failed lekagetest|ATCO NOTE NOCO NOPT|Too high and unstable leakage from DCVs|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000088604|25/10/2012|priority 3 |Q3|Unknown|Unknown|HP signature is wrong|NOCO NOPT ATCO NOTE|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P6000121268|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOCO NOTE NOPT ATCO|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|7104033|27/02/2013|priority 2 |Q3|Unknown|Unknown|Original Production doc. missing|NOTE NOCO ATCO|Missing old documentation for MMR work|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|100020562|22/10/2009|priority 2 |Q3|Unknown|Unknown|BPTH XT SEM Software Punchlist Items|NOTE ATCO NOCO NOPT|BPTH XT SEM Software Punchlist Items|Design |Specification Error|SS - Controls - Topside Products|N/A SW|FMC Other causes/damage |No Non-Compliance
ZB|7104033|04/10/2016|priority 1 |Q1|Unknown|Unknown|GC 187201 wrong tag/use of procedure|ATCO NOTE NOCO|Procedures not followed|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100020562|09/03/2010|priority 3 |Q3|BP|GOM|EC surface corrosion BPTH Prod XT SCM 1|NOCO ATCO NOTE NOPT|EC surface corrosion BPTH Prod XT SCM 1|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000088604|07/11/2012|priority 1 |Q3|Unknown|Unknown|Possible duplicate s/n on Pt`s|NOCO ATCO NOPT NOTE|SN recorded incorectly at warehouse|Marking |Marking content error|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Assy |Operator Error
ZF|P6000104112|08/07/2015|priority 3 |Q3|Unknown|Unknown|Locked/cut threads on EC|NOTE ATCO NOPT NOCO|Threads on EC damaged during assembly|Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|El. Connector|FMC Assy |Damaged during assembly
ZF|7103234|11/11/2005|priority 3 |Q3|OVERALL PROJECT ROLL-UP|Unknown|Control Valve reset is too high|NOCO ATCO NOPT NOTE|Testing method|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Assy |Lack of Training
Q3|7102969|01/10/2002|priority 3 |Q3|EXXONMOBIL|Unknown|SEM failure|NOCO ATCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen goods receipt/inspection|Initial/Direct product problem|Function
ZF|P7000016420|25/11/2010|priority 1 |Q3|Unknown|Unknown|Desvios durante SRT|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Projects Related|Documentation error
ZF|P7000008275|24/06/2010|priority 1 |Q3|Unknown|Unknown|Oxidação na área de montagem do coupler|NOCO NOPT NOTE ATCO|Ponto de oxidação no manifold block|Coating/Plating |Coating defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|100020278|01/12/2010|priority 2 |Q3|Unknown|Unknown|Pin not fit|NOTE NOCO|Change pin to smaller one which fits|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|P7000000897|22/03/2012|priority 1 |Q3|Unknown|Unknown|Mangueiras fora da data de validade|NOTE NOCO NOPT ATCO|Validade da mangueira|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000000897|24/09/2010|priority 2 |Q3|Unknown|Unknown|Revestimento fora da especificação.|NOPT NOCO ATCO NOTE|Unknown|Coating/Plating |Coating not applied|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZB|P6000028371|25/02/2010|priority 2 |Q1|SHELL|GOM|Incorrect Main & Alt Program on SCM 201|NOTE NOCO NOPT ATCO|Incorrect Main & Alt Program on SCM 201|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Processor PCBs|Intercompany|FMC Kongsberg
ZF|P6000028371|27/05/2008|priority 3 |Q3|SHELL|GOM|change in rev for hydraulic assembly|NOPT NOCO NOTE ATCO|Unknown|FMC Other Defect |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P6000039844|28/07/2014|priority 3 |Q3|Unknown|Unknown|PT/TT 3 SEM A not responding to changes|NOCO NOTE NOPT|Wrong marking caused wrong wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 07|ATCO NOPT NOCO NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000008275|10/03/2011|priority 1 |Q3|Unknown|Unknown|Teste de vácuo da outer can|ATCO NOCO NOPT NOTE|Revestimento|Coating/Plating |Incorrect Colour/Coating|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P7000016420|15/12/2011|priority 1 |Q3|Unknown|Unknown|BASE PLATE COM PONTOS DE OXIDAÇÃO|ATCO NOCO NOTE NOPT|VENDOR - PONTOS DE OXIDAÇÃO|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Coating Defect
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOCO ATCO NOPT NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|7103234|31/08/2004|priority 3 |Q3|Unknown|Unknown|Complaint of errors in test procedures|NOPT ATCO NOCO NOTE|Unknown|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Procedure error
Q3|100005667|13/09/2000|priority 2 |Q3|Unknown|Unknown|Tests missing in procedure PRD-0010217|NOTI ATCO NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|100026567|12/05/2003|priority 2 |Q3|Unknown|Unknown|Wrong top  plate|ATCO NOCO NOPT NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100052701|18/09/2007|priority 3 |Q3|Unknown|Unknown|Isolation plug for 12 pin digitr. Conn.|ATCO NOCO NOTE NOPT|Hole is too small for twisted wiring|Assembly/Test Related |Dimension (tolerance)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|7101172|19/03/2001|priority 3 |Q3|Unknown|Unknown|CHECK COMMUNICATION WITH SAND-DETECTOR|ATCO NOCO NOPT NOTI|SIO CARD: UPDATING MAY HAVE BEEN MISSING|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Root cause Vendor|Material/Component error
Q3|7103233|19/11/1999|priority 2 |Q3|Unknown|Unknown|Install hydaulic flow restrictors|NOPT NOCO ATCO NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
ZF|P6000068902|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000104112|22/05/2014|priority 3 |Q3|Unknown|Unknown|Fiber outside of acceptance criteria|ATCO NOCO NOTE NOPT|Common follow-up in QN 200384383|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Material error
ZF|P6000138867|20/09/2017|priority 2 |Q3|Unknown|Unknown|Test requirement in TR1233|NOTE ATCO NOCO|GAP towards Contract req. identified|TEST |Wrong Test Procedure Used|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Engineering related |Engineering Error
ZF|P6000042969|26/08/2010|priority 1 |Q3|TOTAL|WEST AFRICA|Error during pressure test.|ATCO NOCO NOPT NOTE|Operator error  Vendor are informed|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000147859|13/11/2017|priority 3 |Q3|Unknown|Unknown|Leakage from C1 R 2 port- Man. block|NOTE NOPT NOCO|Plug itself was only hand tighten|Assembly |UnderTorqued|SS - Controls - Hydraulic Products|Other Hydraulic Products|FMC Assy |Operator Error
ZF|P7000000897|14/09/2011|priority 3 |Q3|SHELL|Unknown|Marcação ilegível|NOPT NOTE NOCO ATCO|NÃO HÁ NÃO CONFORMIDADE|Marking |Marking Not Readable|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |No Non-Compliance
ZF|100067526|28/11/2014|priority Unknown|Q3|Unknown|Unknown|Missing HFT for SCM PN 100067526|NOCO ATCO NOTE|HFT OMM-0011272 is linked in SAP|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100025661|08/08/2005|priority 3 |Q3|BP|GOM|INTERNAL PT OUT OF RANGE|NOPT ATCO NOCO NOTE|INTERNAL PT OUT OF RANGE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P6000108984|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|7102643|11/09/2003|priority 3 |Q3|Unknown|Unknown|Not conformity between drawing and BOM|NOPT NOTE NOCO ATCO|Unknown|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Material Master/DBI error
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 08  Bytting av trykktrandsusere|NOPT ATCO NOTE NOCO|Unknown|103-Electrical|RCM Electronics|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|7102969|25/03/2010|priority 3 |Q3|Unknown|Unknown|Updates of Drawings for MEGI SCM|NOTE NOCO ATCO|O-ring was missing on DWG and BOM|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100020562|19/07/2013|priority 3 |Q3|Unknown|Unknown|Wrong MWP on SCM Nameplate|NOTE ATCO NOCO NOPT|Incorrect marking on nameplate|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100036936|31/05/2018|priority 3 |Q1|Unknown|Unknown|Urd  SCM  silicon lekkasje|NOTE NOPT ATCO NOCO|leakage ion the hose connecti|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|100037967|22/01/2008|priority 1 |Q3|BP|Unknown|SEM A FAILURE ON MCM S3|NOTE NOCO NOPT|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
ZF|100036232|17/11/2014|priority Unknown|Q3|Unknown|Unknown|Cust Dev Crack on Cap|ATCO NOCO NOPT NOTE|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|Other el/opt components|FMC Assy |Missing Operation
ZF|100031223|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|P7000000897|26/01/2012|priority 1 |Q3|Unknown|Unknown|Item sem Set Out|NOPT ATCO NOCO NOTE|Item sem set out|Assembly Related |OBS-Component TraceabilityNot Maintained|FKS Quality system issues|Measuring  Analysis & Improvement|FMC Materials/Stores related |Lack of Training
ZF|P6000043122|16/10/2009|priority 3 |Q3|Unknown|Unknown|ESS config file must be updated|NOCO NOTE ATCO NOPT|Unknown|Design |Unknown|SS - Controls - Topside Products|N/A SW|FMC Engineering related |Unknown
ZF|P7000024191|11/10/2012|priority 1 |Q3|Unknown|Unknown|TESTE HIPERBÁRICO|ATCO NOTE NOPT NOCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|7102969|26/05/2005|priority 3 |Q3|EXXONMOBIL|Unknown|SCM OVER PRESSURE|ATCO NOTE NOPT NOCO|LP hyd. over pressured during testing|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO NOPT ATCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000105542|09/01/2015|priority Unknown|Q3|Unknown|Unknown|NCR-Deviation from “no dead end” princip|NOTE NOCO ATCO|Unknown|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Fabrication Shop Personnel |Operator error
ZF|100030542|18/03/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|Unknown|COM test on SCM 23|NOTE NOPT NOCO|Wrong accept. criteria in PRD-0000022442|Documentation |Incorrect user documentation (customer)|SS - Controls - Sensors|SCM Flowmeter|FMC Engineering related |Engineering Error
ZF|100054943|25/01/2008|priority 3 |Q3|WOODSIDE|Unknown|missing batch numbers|NOTE NOPT NOCO|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOCO ATCO NOPT NOTE|PSM not followed  short mob time|Assembly/Test Related |Do Not Use|FKS Quality system issues|Resource Management|FMC Assy |Missing Operation
ZF|100025661|19/02/2004|priority 2 |Q3|Unknown|Unknown|ACCUMULATOR IS NOT FLUSHED|NOTE ATCO NOCO NOPT|Contamination|Assembly / Test related |Cleanliness|Subsea Control Module (SCM) Hydraulic|Accumulators|Vendor related|Assembly error
ZF|100048038|24/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|Scratches on the base plate.|NOCO NOPT NOTE ATCO|damaged during movement in workshop|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P6000069820|22/03/2011|priority 1 |Q3|CONOCOPHILLIPS|Unknown|Cleaning Sequence Table is wrong|ATCO NOTE NOCO NOPT|Cleaning Sequence Table is wrong|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000020444|26/07/2011|priority 1 |Q3|Unknown|Unknown|Fiber penetrator damaged|NOCO NOTE ATCO NOPT|Arrived Damaged from ODI|Raw Material |OBS-Defects in material|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Equipment Malfunction
ZF|P6000058949|07/09/2010|priority 1 |Q3|STATOIL|NORTH SEA|leaking on test|NOPT NOTE NOCO|Incorrect screw quality used in BOM|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000079433|12/10/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Flushing procedure is wrong|NOTE NOCO NOPT ATCO|Sequence in flushing procedure wrong|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #6 Wiring|NOCO ATCO NOTE NOPT|BPTH SKOFLO SCM SN #6 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000100953|10/12/2013|priority 3 |Q3|Unknown|Unknown|Measured 0Volt on EC1 pin 9 and 10|NOTE NOCO ATCO NOPT|Operator error (wrong connection on EC)|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000001843|26/06/2018|priority 3 |Q3|PETROBRAS|Unknown|MMR - Broken Screw on Base Plate|NOCO NOTE ATCO|Incorrect Tool|Machining |Thread Error|Object Types to Eng Matl CLASS|scm_mkIIE|Machining |incorrect tool
ZF|100025661|04/10/2005|priority 3 |Q3|SHELL|GOM|HFT DOCUMENT DISCREPENCY|NOCO ATCO NOTE NOPT|HFT DOCUMENT DISCREPANCY|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|100049000|13/04/2012|priority 2 |Q3|BP|GOM|SCM 23  Visual inspection / Seal inspect|NOCO NOPT NOTE ATCO|SCM 23 Wrong pressure test performed|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000020444|29/08/2011|priority 1 |Q3|Unknown|Unknown|Flowmeter Não Conforme|NOTE ATCO NOCO NOPT|Flow technology|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000065886|27/12/2010|priority 2 |Q3|ENI|NORTH SEA|CPU600 improving startup on long umbilic|NOTE ATCO NOCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000088614|27/05/2014|priority 4 |Q3|Unknown|Unknown|The DU are not the same|NOPT NOTE NOCO ATCO|Drawings updated to reflect each other|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000079032|05/06/2012|priority 2 |Q3|STATOIL|NORTH SEA|PSD B card selftest fails on DO#5 Core 1|NOTE ATCO NOCO|Follow-up in QN200279946|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100037967|15/03/2006|priority 1 |Q3|BP|Unknown|Some drops of water in silicon sample|NOCO NOTE NOPT|cancelled QN|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |QN Cancelled
ZB|7101172|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|AI card at SEM B at SCM is not working|ATCO NOPT NOCO NOTE|AI card might be of batch with failure|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Do Not Use
ZF|P7000016420|02/08/2011|priority 1 |Q3|Unknown|Unknown|Interior de Manifold Block com cavacos|ATCO NOCO NOTE NOPT|Bosch - manifold block c/ cavacos|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|100035400|16/01/2006|priority 3 |Q3|LLOG|Unknown|FAILURE TO OPPERATE TO HFT REQUIREMENTS|ATCO NOTE NOPT NOCO|HFT DOCUMENT ERROR|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
Q3|7101172|17/03/2000|priority 2 |Q3|Unknown|Unknown|GFS SCM 06  Down hole pressure gauge.|NOPT NOCO ATCO NOTI|Smedvig supplied DHG at fault|103-Electrical|Printed Circuit Board|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider på ventiler.|NOCO NOTI ATCO NOPT|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
Q3|7100320|06/07/2000|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Hercules SCM 19|ATCO NOPT NOTI NOCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|P6000077632|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000016420|30/08/2011|priority 1 |Q3|Unknown|Unknown|Extension Rod / P55-09|ATCO NOPT NOCO NOTE|UVDAL|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Damage during transport
ZF|100020562|14/10/2010|priority 1 |Q3|BP|GOM|BPTH SCM 28-need to determine SW|NOCO NOTE|Documentation wasn't correct.|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|P7000001621|15/02/2011|priority 1 |Q3|Unknown|Unknown|Comprimento de rosca insuficiente.|NOTE NOCO NOPT ATCO|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZC|100046112|05/07/2012|priority 2 |Q2|Unknown|Unknown|Angel SESI not comply with testing docs|NOPT NOTE NOCO ATCO|Error in procedures is updated.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000068924|27/01/2012|priority 3 |Q3|TOTAL|Unknown|Current reading is outside accept crit.|NOPT NOCO NOTE ATCO|Corrected by SW-calibration|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|100029062|11/04/2011|priority 1 |Q3|TOTAL|Unknown|Down Hole Gauge testing failure with SCM|NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Equipment Malfunction
ZB|P6000105542|21/01/2016|priority 2 |Q1|Unknown|Unknown|Gullfaks GSO claim 297 SEM Bnocom SUBSEA|ATCO NOTE NOCO|Accepted to close SCM subsea|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000039672|09/06/2014|priority 1 |Q3|Unknown|Unknown|Missing screws in ODI Connector|ATCO NOPT NOTE NOCO|1021 - Teledyne Oil and Gas|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Missing Parts
ZF|100030542|18/02/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|Unknown|COM test on SCM 22|NOPT NOTE NOCO ATCO|Wrong accept. criteria in PRD-0000022442|Documentation |Incorrect user documentation (customer)|SS - Controls - Sensors|SCM Flowmeter|FMC Engineering related |Engineering Error
ZF|100020562|24/04/2010|priority 2 |Q3|BP|GOM|SCM not functioning properly|NOCO NOPT ATCO NOTE|SCM  not functioning properly|Change/Deviation Request |Process substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZB|P6000042968|02/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 09|NOCO NOTE ATCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000060453|10/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|Software  - function removed|NOCO NOTE ATCO NOPT|Error in Communication Data Allocation|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Specification error
ZF|100052701|11/05/2010|priority 3 |Q3|STATOIL|NORTH SEA|Tyr F&D 12 LAck of nitrogen in SCM|NOPT NOCO NOTE|Unknown|FMC Other Defect |Part Lost|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Machine Shop Personnel |Lack of Training
ZF|100035118|08/08/2005|priority 3 |Q3|Unknown|Unknown|SCM|NOPT NOTE ATCO NOCO|Documentation not distributed.|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
Q3|7101172|29/11/1999|priority 3 |Q3|Unknown|Unknown|Check valve damaged when installed on XT|NOTI ATCO NOPT NOCO|Assembly error after testing in Bergen|101-Mechanical|Mechanical Components|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Damages
Q3|100017305|13/11/2002|priority 3 |Q3|STATOIL|Unknown|Sølvbelagte skruer (silver platted screw|ATCO NOTI NOCO NOPT|Wrong screw used for SCM|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
Q1|100018820|28/01/2003|priority 3 |Q1|EXXONMOBIL|NORTH SEA|SIGYN A-1H SCM#3 status buffer trigged|NOCO NOPT ATCO NOTE|QN is transferred to SN 300025059|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Sleipner/Loke|Initial/Direct product problem|Function
ZF|3794920|10/08/2006|priority 3 |Q3|Unknown|Unknown|Errors in SCM FAT procedure|ATCO NOCO NOTE NOPT|Unknown|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100034440|12/10/2005|priority 2 |Q3|Unknown|Unknown|Documents/drawings must be updated|ATCO NOPT NOTE NOCO|Unknown|Design |Material Master Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q3|7105128|09/02/2000|priority 1 |Q3|Unknown|Unknown|SCM P 04|ATCO NOCO NOTI NOPT|Chromate coating. Now changed to Xylan|101-Mechanical|Locking Mechanism|Defect locations - onshore|KOS Kbg. X-mas tree/FCM workshop|Initial/Direct product problem|Function
ZF|100029564|26/08/2004|priority 3 |Q3|PETROBRAS|Unknown|The records from tank test was lost|NOCO NOTE NOPT|Computer failure at CBV|Unknown|Unknown|Unknown|Unknown|Other external causes|Customer Error/responsibility
ZD|P6000067533|12/07/2011|priority 2 |Q2|KIRINSKOYE SPS|Unknown|Error in ELD60060320 for Kirinskoy.|ATCO NOCO NOTE|Forgot to evaluate wiringdiagram changes|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000068770|23/09/2011|priority 2 |Q3|TOTAL|Unknown|Outer-can mech BOM in SAP is incorrect.|NOTE NOCO ATCO|Engineering error. LST and PN corrected|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DBI error
ZF|P6000042969|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|SCM to be upgraded acc. to DRM60046044/A|NOPT NOTE NOCO ATCO|Designe error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Specification error
Q3|7101172|30/08/2000|priority 3 |Q3|STATOIL|NORTH SEA|SCM LP hyd leak on well H-2H  (1.2L/hr)|ATCO NOCO NOPT NOTI|Control valve leaking|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
Q3|7104670|02/02/2001|priority 2 |Q3|Unknown|Unknown|SCM 9 pin Tronic coupl.forced into 12pin|NOCO NOTI ATCO NOPT|Unknown|202-Electrical/Sensor equipment|Electrical Pin Connetors|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Damages
ZF|100017278|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZB|100051269|10/09/2008|priority 4 |Q1|STATOIL|NORTH SEA| SEM A not working.|ATCO ORAS NOPT NOTE NOCO|Replace SCM|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000103208|10/04/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7104670|12/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM communication probl. v/sem B|ATCO NOPT NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZF|7102969|01/03/2006|priority 3 |Q3|Unknown|Unknown|bad internal PT|NOTE NOPT NOCO ATCO|Defective Internal PT|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZB|100030542|11/10/2005|priority 1 |Q1|Unknown|Unknown|SCM Flushing with wrong fluid|NOCO NOTE ATCO NOPT|Procedure not followed.|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100059660|05/11/2009|priority 2 |Q3|Unknown|Unknown|Drawing document wrong|NOCO NOTE NOPT ATCO|SEM brackets drawing wrong engineered|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|SCM Change Hydraulic Fluid|NOCO ATCO NOTE|SCM shipped to be reflushed|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000110991|22/01/2014|priority 4 |Q3|Unknown|Unknown|Missing earthstraps on EC's baseplate|NOCO NOPT NOTE ATCO|Missing earth connection towards ECs|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P7000039672|02/04/2015|priority 1 |Q3|Unknown|Unknown|Rosca de adapter plate danificada|NOTE ATCO NOCO NOPT|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Operator Error
ZF|100048038|16/02/2006|priority 2 |Q3|Unknown|Unknown|PIPE IS IN TOUCH WITH THE EL. BRACKET.|NOPT NOTE NOCO ATCO|pipe route is too close to SEM bracket|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|Missing rubber prot.inside comp. chamber|NOPT NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000001843|23/06/2010|priority 1 |Q3|Unknown|Unknown|Teste não realizado|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Assy |Operator Error
ZF|P6000100953|10/06/2013|priority 3 |Q3|Unknown|Unknown|Wrong in new Config|NOPT NOTE NOCO ATCO|Unknown|Documentation |Procedure / Process Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Procedure error
ZF|3794920|16/06/2006|priority 3 |Q3|STATOIL|NORTH SEA|Internal leakage test outside criteria|NOPT ATCO NOCO NOTE|leakage accepted at 0.21ml|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Vendor audit related|Unknown
ZF|100036936|22/11/2007|priority 2 |Q3|STATOIL|NORTH SEA|HFT not performed|NOCO NOPT NOTE ATCO|Due to lack of time|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
Q3|7105597|Unknown|priority 3 |Q3|Unknown|Unknown|Wrong basic data|NOPT NOCO NOTI ATCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P6000028371|18/10/2007|priority 3 |Q3|Unknown|Unknown|airpockets in glue|NOPT NOCO ATCO NOTE|Material err.  No impact on function|Coating |Coating Defects|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Vendor related |Fabrication error
ZD|100020562|01/03/2007|priority 1 |Q2|BP|GOM|SCM INTERNAL PT'S FAILED|NOCO ATCO NOPT NOTE|Insufficient cleaning during man.|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P6000088614|26/08/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000042968|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|SCM to be upgraded acc. to DRM60046044/A|ATCO NOTE NOPT NOCO|Designe error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Specification error
ZF|P6000058949|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|NOCO ATCO NOTE|DWG error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P7000039672|13/11/2015|priority 1 |Q3|Unknown|Unknown|Restrição na Linha do SCM|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Equipment Malfunction
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7103234|15/11/1999|priority 2 |Q3|Unknown|Unknown|Install hydaulic flow restrictors|NOTI ATCO NOCO NOPT|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
ZF|P6000069056|23/01/2012|priority 3 |Q3|HYME PROJECT|Unknown|Insufficient wall thickness in m. block|ATCO NOCO NOPT NOTE|Ref. QN 200241870|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
ZF|P6000093498|11/11/2014|priority 3 |Q3|Unknown|Unknown|"SMU card entering ""System Error"""|NOPT ATCO NOCO NOTE|Board failure  followed up in ZF QN|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Equipment Malfunction
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOTE NOPT NOCO|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
Q1|7105129|15/08/2002|priority 2 |Q1|TOTAL|Unknown|SCM 02 GIR SEM A malf(silicon in el-can)|NOPT NOCO NOTI|Silicon in el.can|101-Mechanical|El.Can Bracket|Ext. Loc. - Luanda (Angola)|Work Shop|Initial/Direct product problem|Leakage
Q3|7100320|17/02/2000|priority Unknown|Q3|Unknown|Unknown|Skifte solenoider ventiler sn. 16|NOCO NOPT NOTI ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000116166|27/10/2015|priority 3 |Q3|Unknown|Unknown|Screw got stuck|NOTE NOCO NOPT|Screw got stuck during assembly|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Damaged during assembly
Q3|3794920|19/09/2000|priority 2 |Q3|Unknown|Unknown|SSP SCMs 28  42  44: various punches|NOPT NOTI ATCO NOCO|Unknown|Quality System Issues|KOS Quality system issue|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P6000064910|27/12/2010|priority 2 |Q3|TOTAL|NORTH SEA|CPU600 improving startup on long umbilic|NOPT NOCO ATCO NOTE|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE NOCO NOPT ATCO|Wrong type of screws used on valves|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|7101401|03/06/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Couplers external leakage|NOPT ATCO NOTE NOCO|Unknown|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Service Related:|Damaged during installation
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000069820|04/07/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|incorrect rev of procedure is used|NOTE NOCO|Ref QN: 200213490.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000063531|01/12/2010|priority 2 |Q3|Unknown|Unknown|Wrong S/n on one valve in the i basa|NOCO NOTE NOPT|Ibase list wrong acc to physical s\n|Assembly Related |OBS-Component TraceabilityNot Maintained|SS - Controls -SCM  hyd/mech components|Control Valve|Intercompany|FMC Kongsberg
ZF|100049392|13/07/2006|priority 4 |Q3|Unknown|Unknown|3162F&34 - no SCM to XT base plate fit|NOTE ATCO NOPT NOCO|Wear and tear|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100035118|15/10/2004|priority 2 |Q3|WOODSIDE|Unknown|WATER IN THE SILICON SAMPLE|ATCO NOCO NOTE NOPT|Test equipment damaged during test.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Assembly/Test related|Operator error
ZF|100037967|06/03/2006|priority 1 |Q3|BP|Unknown|Water detected in SCM after Hyperbaric|NOTE NOCO ATCO NOPT|Drain plug not tightened|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|100016901|24/07/2002|priority Unknown|Q3|BP|GOM|Leakage between CV and Man. Block|NOPT NOTI NOCO ATCO|Leakage|102-Hydraulic|Hydraulic Control Valves|Unknown|Unknown|Root cause Assembly/Test|Workshop-Assembly/Test error
Q3|7103233|01/12/2000|priority 4 |Q3|OVERALL PROJECT ROLL-UP|Unknown|SCM returned for upgrading of PTs|ATCO NOCO NOPT NOTI|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Vendor|Design error
ZF|100046112|17/11/2005|priority 3 |Q3|Unknown|Unknown|Implementation and test of Fast Scan|NOCO ATCO NOTE NOPT|QN established to manage tasks|Design |Do Not Use|FKS Quality system issues|Product Realization|FMC Other causes |No Non-Compliance
ZE|P6000069820|25/09/2012|priority 2 |Q3|Unknown|Unknown|COPI Platform Comms Startup Shutdown|NOTE NOCO ATCO NOPT|Unable to establish communication|Unknown|Unknown|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Variance|Capture Mistake
ZF|P6000063531|15/03/2011|priority 3 |Q3|Unknown|Unknown|Incorrectly connected 0V wire EC 3 plug|NOCO NOPT NOTE ATCO|Human error. Wires connected wrong|Test Related |OBS-Function|SS - Controls -SCM el/opt components|SCM Wiring|FMC Machine Shop Personnel |Operator error
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 09|NOTE NOPT NOCO ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000039672|06/04/2018|priority 1 |Q3|Unknown|Unknown|Conexão grimpada|NOPT ATCO NOCO NOTE|Unknown|Damage |Damage during testing|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Other causes/damage |Cause not found
ZE|P6000103208|17/10/2016|priority 4 |Q3|Unknown|Unknown|(E) - SCM power supply and smoke issues|NOTE NOCO ATCO NOPT|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Electrical |Design Error
ZF|P7000039672|20/06/2014|priority 1 |Q3|Unknown|Unknown|Atualização do modem MRM das Eletrônicas|NOTE NOPT ATCO NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Engineering related |Continuous Improvement
ZB|100020562|30/07/2008|priority 3 |Q1|BP|GOM|Erratic pressure readings.|NOPT NOTE NOCO|Erratic pressure readings.|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P6000042969|13/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|red hydraulic dust caps left on XT|NOCO ATCO NOPT NOTE|Red protector Caps lef on SCMMB|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
Q3|7100320|Unknown|priority Unknown|Q3|Unknown|Unknown|Oppgrader Hercules 03|ATCO NOPT NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100017278|04/12/2008|priority 3 |Q3|STATOIL|NORTH SEA|Error on L-4H  - SCM - SEM B|NOPT NOCO NOTE ATCO|Falt on SEM B|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P7000008275|01/06/2010|priority 2 |Q3|Unknown|Unknown|Assinatura de válvulas SCM 06 TBU|NOTE NOPT ATCO NOCO|defeito durante o teste|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZF|P6000103208|09/07/2014|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO NOPT ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000138867|18/05/2018|priority 3 |Q3|Unknown|Unknown|SCM  Wrong on MAC adress plate|NOCO NOTE ATCO|Wron MAC address on name plate.|Marking |Marking content error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Marking |Incorrect Marking
ZF|P6000028371|06/05/2008|priority 1 |Q3|SHELL|GOM|MPFM are not working properly on SEM B|NOCO NOPT NOTE|Mismatch dual Core PC and MPFM program|Test Related |OBS-Function|SS - Controls - Sensors|Flowmeter|Vendor related |Programmer Error
ZB|100001156|07/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|Guarantee claim 107 - Comm.failure SEM B|NOCO NOPT NOTE|Too high leakage rate at COV|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P7000016420|13/05/2011|priority 1 |Q3|Unknown|Unknown|Problema de comunicação com a placa TIF|NOTE ATCO NOPT NOCO|Software|Test Related |OBS-Function|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Engineering related |Specification error
Q3|3812476|08/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  PMV doesn't open with SEM A|NOCO ATCO NOPT NOTI|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Function
Q3|7101172|Unknown|priority 3 |Q3|Unknown|Unknown|Feil og mangler i prosedyre Gfs/Åsg.|NOPT NOTI ATCO NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
ZF|100052701|15/04/2008|priority 3 |Q3|STATOIL|NORTH SEA|batch numbers missing|NOTE NOPT NOCO|Unknown|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|Shell SCM Communication problem|NOCO ATCO NOPT NOTE|Vendor changed colors on wires|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Shell Alliance GOM|Root cause Vendor|Assembly/Fabrication/Test error
ZE|P6000042968|11/03/2010|priority 3 |Q3|TOTAL|WEST AFRICA|DHI error message received in ST report|NOCO NOTE ATCO|Documentation|Unknown|Unknown|SS - Controls - Topside Products|N/A SW|Causes for Improvement|Documentation
ZF|P6000042968|19/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Material not delivered to plant|ATCO NOCO NOPT NOTE|FMC Engineering related: Process error|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZB|100001156|20/09/2005|priority 4 |Q1|STATOIL|NORTH SEA|Failure on pressure indicator in new SCM|NOCO ATCO NOTE NOPT|A sensor is not functioning acc.|Assembly/Test Related |Function|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|FMC Machine Shop Related |Tooling
ZF|P6000104113|19/08/2014|priority 4 |Q3|Unknown|Unknown|Update KS200e SW for Egina|NOTE NOCO ATCO|Com. functionality which was not cons.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
Q1|3801623|02/10/2000|priority 3 |Q1|Unknown|Unknown|SCM anodes mounted wrong|NOPT ATCO NOCO NOTI|Assembly error|101-Mechanical|Outer Can|Unknown|Unknown|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOCO NOPT NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|100036936|01/08/2005|priority 3 |Q2|STATOIL|NORTH SEA|WASHERS FOR ISOLATION PLUGS ARE LOOSE|NOPT NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|P6000064911|10/06/2016|priority 3 |Q1|Unknown|Unknown|Defect Not. 08 - SRM A Tormore|NOCO NOTE|cause unknown - no liabiliy for FMC|Electrical |Performance|FKS Quality system issues|Quality Management System|Electrical |Other- Specify in comments
ZF|P6000064909|24/05/2011|priority 2 |Q3|TOTAL|Unknown|position on orientation pins EC`s outerc|NOTE ATCO NOCO|DWG error(Pos of orientation pins on EC)|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000069820|04/07/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|incorrect rev of procedure is used|NOCO NOTE|Ref QN: 200213490.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P7000001621|10/03/2010|priority 1 |Q3|Unknown|Unknown|Agua no Conector de Base|NOTE NOPT ATCO NOCO|SCM Removal from hydrated slot|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZE|100035118|11/01/2016|priority 3 |Q3|Unknown|Unknown|WEL  Test Failure  L1 Escape|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000063531|29/01/2016|priority 3 |Q3|Unknown|Unknown|Acoustic Leak Detector test in HFT|NOCO NOPT NOTE ATCO|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000098616|12/06/2013|priority 1 |Q3|Unknown|Unknown|Silicone drainport loose.|NOTE ATCO NOCO|Drain port not torqued  see RCA.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|ATCO NOCO DLFL|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P7000024900|14/09/2011|priority 1 |Q3|Unknown|Unknown|BC-10 SN 22 phase 2.|NOPT NOTE NOCO|Shell need the SCM without some tests.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZD|100020562|26/11/2013|priority 3 |Q2|Unknown|Unknown|Outer can stripes|NOCO ATCO NOTE|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|Paintshop Related|Operator error
ZF|P6000100953|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 14|ATCO NOCO NOPT NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100049000|22/05/2009|priority 2 |Q1|Unknown|Unknown|DHFC SCM 04 RAM Warning|NOTE NOCO|Defective RAM chip|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
Q3|7102643|Unknown|priority 3 |Q3|Unknown|Unknown|HC17/18 valves changed place.|NOCO NOPT ATCO NOTI|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
Q3|3794920|Unknown|priority 1 |Q3|Unknown|Unknown|Elect. fault occured when landing SCM|NOPT ATCO NOTI NOCO|Pin conn. damaged (possibly offshore)|202-Electrical/Sensor equipment|Electrical Pin Connetors|Defect locations - offshore/field|Sleipner/Loke|Initial/Direct product problem|Function
ZF|P7000001621|02/04/2014|priority 1 |Q3|Unknown|Unknown|Base Plate - Morsas|NOTE NOCO NOPT ATCO|Impacto lateral no pino guia.|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Service Related:|Damaged during installation
ZF|100020278|01/12/2010|priority 2 |Q3|Unknown|Unknown|Pin not fit|NOTE NOCO NOPT|Change pin to smaller one which fits|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|100035118|19/03/2007|priority 3 |Q3|WOODSIDE|Unknown|Locking mechanism needs refurbishment|NOCO ATCO NOTE NOPT|Line missing in prosedure|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P6000058949|17/03/2011|priority 3 |Q3|Unknown|Unknown|PT results fluctuate running on SEM A|ATCO NOPT NOCO NOTE|Short circuit in LP FM.  ref QN200200560|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000104112|18/01/2016|priority 2 |Q3|Unknown|Unknown|SCMs Fliud Issue for WI XTs|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000001621|27/08/2010|priority 1 |Q3|Unknown|Unknown|camada de pintura fora do especificado|ATCO NOCO NOPT NOTE|Camada de revestimento acima|Coating/Plating |Painting Defect|SS - Compl. & W.Over - XT - General|Horizontal Penetrators|Paintshop Related|Operator error
ZF|P6000074156|06/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOPT ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|05/09/2018|priority 1 |Q3|Unknown|Unknown|ECN  7090703    PN  P7000017838|ATCO NOTE NOCO NOPT|Error-concept/calculation|Design |DBI Error|Object Types to Eng Matl CLASS|kits|FMC Engineering related |ECN Change
ZF|P6000068924|21/12/2012|priority 2 |Q3|TOTAL|Unknown|MMRSRM Clov 7 Fiber Connection|NOCO ATCO NOTE|Bad welding on fiber in SCM outher can|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Assy |Operator Error
ZB|100020562|26/08/2009|priority 3 |Q1|BP|GOM|No Pressure reading on PT2|NOTE ATCO NOPT NOCO|No Pressure reading on PT2|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000116166|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOCO NOPT NOTE ATCO|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|100015314|09/08/2010|priority 3 |Q3|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|Unknown|Contamination found in SCM silicone oil|NOPT NOTE ATCO NOCO|Burst bladder due to long time storage|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000068902|04/06/2013|priority 2 |Q3|Unknown|Unknown|no traceability on trafo parts|NOTE NOCO|All parts recorded correctly.|Design |DBI Error|SS - Controls -SCM el/opt components|Trafo Unit|FMC Other causes/damage |QN Cancelled
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|NOPT NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|3812476|27/12/1999|priority 3 |Q3|STATOIL|NORTH SEA|Internal hydraulic leak in SCM|ATCO NOCO NOTI NOPT|Hyd leak in SCM CVs/cause not known|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Leakage
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-018: RAM Warning Error|NOTE NOCO|Error Message|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZB|7104670|16/03/2006|priority 3 |Q1|STATOIL|NORTH SEA|Leak in Subsea Control Module on HXT|ATCO NOTE NOCO NOPT|The module have not been refurb.|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100037428|15/06/2012|priority 2 |Q3|TOTAL|WEST AFRICA| Check valve found missing (SCM)|NOCO ATCO NOTE|Unknown|FMC Other Defect |Part Lost|SS - Controls - Hydraulic Products|Relief Valve|FMC Materials/Stores related |Improper Packaging & Storage
ZB|P7000002082|12/06/2017|priority 2 |Q1|Unknown|Unknown|FNCR 2604 - SCM SN-03 Plangas - AI Board|NOPR NOTI OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000000897|06/02/2012|priority 1 |Q3|Unknown|Unknown|coupler vazando.|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Assy |Damaged during assembly
ZF|100052701|06/03/2008|priority 3 |Q3|STATOIL|NORTH SEA|batch on nuts and bolt missing|NOCO NOTE NOPT|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|100050519|04/10/2006|priority 3 |Q3|TOTAL|Unknown|Leakage  Hydraulic|NOCO ATCO NOPT NOTE|leak measurements compromised by CHKV|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|7100320|17/12/2001|priority 3 |Q3|PETROBRAS|Unknown|SCM 19 Hercules CVLP/AI board failure|NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Leakage
ZE|P6000074156|02/07/2014|priority 4 |Q3|Unknown|Unknown|Found silicone leaking out from SCM|NOCO ATCO NOPT NOTE|Silicone leaking|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Discoloured outercan black lines|NOTE NOCO NOPT ATCO|Paint lines faded after hyperbaric|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|100006609|19/04/2011|priority 2 |Q3|Unknown|Unknown|Furações fora de centro.|NOTE NOCO NOPT ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|SEM Can|FMC Purchasing related |Purchasing Error
Q3|100020562|11/10/2002|priority 2 |Q3|BP|GOM|Faults on SCM delivered to Houston|ATCO NOPT NOTI NOCO|FKS design errors||100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Work Shop|Root cause Engineering|Delivered parts not acc. to BOM/Spec.
Q3|7102643|09/11/1999|priority 2 |Q3|STATOIL|NORTH SEA|AWV PT no indication on both SEMs (R1-H)|ATCO NOCO NOTI NOPT|Internal short circuit on PLFS160  SEMA|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q3|7104670|21/09/2000|priority 2 |Q3|Unknown|Unknown|Suspect CIDV is clogged  well D-2H|NOPT NOTI NOCO ATCO|Contaminated  refer to QN200007024|102-Hydraulic|Chemical Control Valves|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
ZF|100058509|10/11/2009|priority 2 |Q3|LLOG|Unknown|Bad paint jobb outercan|ATCO NOPT NOCO NOTE|Bad Paint job and dirty Outercan|Coating/Plating |Incorrect Colour/Coating|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P7000016420|30/08/2011|priority 1 |Q3|Unknown|Unknown|Extension Rod / P55-09|NOTE NOCO NOPT|UVDAL|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Damage during transport
ZF|P6000067533|04/03/2011|priority 3 |Q3|Unknown|Unknown|PT doesn't show values|NOCO NOPT ATCO NOTE|Incorrect wiring of PT|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000039672|01/10/2018|priority 2 |Q3|Unknown|Unknown|ECN 7090703 -  P7000039672 - PRE SAL|ATCO NOTE NOCO|CHANGE OF ITEMS 6 AND 10 FROM DBI.|Design |DBI Error|Object Types to Eng Matl CLASS|clamps_common|FMC Engineering related |ECN Change
Q3|7101401|Unknown|priority 3 |Q3|Unknown|Unknown|Replace Marlim SCM lee Plugs|NOPT ATCO NOTI NOCO|Wrong material|101-Mechanical|Hydraulic Manifold Block|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000121268|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOPT NOTE NOCO ATCO|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|P6000079032|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|Insufficient wall thickness in m. block|NOCO NOPT ATCO NOTE|Ref. QN 200241870|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
ZF|P7000001843|21/11/2009|priority 1 |Q3|Unknown|Unknown| -R.N.:|NOPT ATCO NOCO NOTE|Unknown|Welding related |Structural NDE defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
Q1|7103233|22/04/2002|priority 3 |Q1|Unknown|Unknown|Accumulator N2 fitting different type|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100037427|12/07/2018|priority 4 |Q3|Unknown|Unknown|CTR 513 Mob Rejected by COMPANY|ATCO NOCO NOTE|procedure not followed at client request|TEST |Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100048038|31/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|Trafo problems on Agbami S/N 26|NOCO ATCO NOPT NOTE|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P6000055605|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000024191|02/05/2012|priority 1 |Q3|Unknown|Unknown|Vazão não atendida nno Flushing|ATCO NOPT NOTE NOCO|Erro no procedimento|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZD|100048038|21/03/2007|priority 3 |Q2|CHEVRON|WEST AFRICA|SEM INTERNAL PRESSURE SENSOR|NOPT ATCO NOCO NOTE|Defective connector against PTR150 board|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|'Choke open' control valve malfunction|NOCO ATCO NOPT NOTI|control valve seat wear|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Shell Alliance GOM|Initial/Direct product problem|Leakage
Q3|7103479|06/09/2000|priority 3 |Q3|Unknown|Unknown|LP hydraulic leak of 600 litres/day|ATCO NOPT NOTI NOCO|Control valve leaking|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Leakage
ZF|P6000069056|29/09/2014|priority 2 |Q3|Unknown|Unknown|Mismatch between GA and TDI|NOCO ATCO NOTE|Name plate not marked acc to GA|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|7104670|24/04/2014|priority 1 |Q1|Unknown|Unknown|GC 262 hydraulic fault (Statoil Heidrun)|NOTE NOCO ATCO|Operator Error|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 7 RCA Actions_2 from RPT10033107|NOPT NOCO ATCO NOTE|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Process/Procedure Ineffective
ZD|P6000147469|19/12/2017|priority 1 |Q2|Unknown|Unknown|Certs issue|NOTE NOCO ATCO|Unknown|Certification |Not available|Object Types to Eng Matl CLASS|scm_assy|Documentation Requirement |Missing
ZF|P6000060453|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Planning error
ZF|P6000080733|05/10/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according HFT|NOCO ATCO NOPT NOTE|DHI not configurated toward simulator|TEST |Missed Operation|SS - Controls -Instrumentation|Other SCM instruments|FMC Test |Missed operation
ZF|100056176|31/10/2013|priority 2 |Q3|Unknown|Unknown|SCM recived in workshop un washed.|NOTE NOCO|Unknown|Project|Project Requested Unfinished shipment|Customer Compliant|Noncompliance to Customer Requirement|FMC Assy |Operator Error
ZF|P7000008275|09/06/2010|priority 1 |Q3|Unknown|Unknown|Teste hiperbárico|NOTE NOCO NOPT ATCO|Não estabilização de pressão|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
Q3|7104033|07/12/1999|priority 1 |Q3|Unknown|Unknown|Hyd press. drop during valve operations|NOCO NOTI ATCO NOPT|Need hyd flow restrictors|102-Hydraulic|Accumulators|Defect locations - offshore/field|Statfjord C|Root cause Engineering|Design Specification error
ZF|100017278|14/12/2005|priority 2 |Q3|STATOIL|NORTH SEA|SCM  57 ÅSG DHI109 switch wiring to conn|ATCO NOPT NOTE NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000055198|22/02/2010|priority 3 |Q3|Unknown|Unknown|Power-control DHI 118 is not working|NOTE NOPT NOCO ATCO|Unknown|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|P7000039672|29/05/2013|priority 1 |Q3|Unknown|Unknown|Incorrect diameter of o-ring|ATCO NOTE NOPT NOCO|PO 47627521-6 - Teledyne Oil & Gas|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Wrong Part Delivered
ZF|100038200|27/02/2006|priority 3 |Q3|Unknown|Unknown|HFT 0000021252 is completely incorrect|NOCO NOTE ATCO NOPT|HFT Doc. Not Correct|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOTE NOCO NOPT|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZF|100037428|06/06/2007|priority 2 |Q3|TOTAL|WEST AFRICA|Rosa XT P9 with missing parts|NOCO NOPT NOTE ATCO|Unknown|Assembly/Test Related |Assembled Incorrectly|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Assy |Operator Error
ZF|100059660|07/07/2010|priority 4 |Q3|STATOIL|NORTH SEA|B&B07 DHPG malf. during flowing of well|NOCO NOTE NOPT|DHPG malfunction|Design |Specification Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Specification error
ZB|100031223|28/10/2014|priority 1 |Q1|Unknown|Unknown|GC 268-SCM Comm. probl.|NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZE|100017278|10/08/2015|priority 3 |Q3|Unknown|Unknown|Misguiding information in PRD-0000024365|ATCO NOPT NOTE NOCO|Procedure updated|Unknown|Unknown|SS - Controls - Electronic Boards|Other Eletronic Boards|Causes for Improvement|Process/Procedure Not Being Followed
ZF|100035118|30/09/2005|priority 3 |Q3|WOODSIDE|Unknown|Silicone Compensator burst.|NOCO ATCO NOTE NOPT|Marginal design.|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|100030542|01/04/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOCO ATCO NOTE NOPT|Wear and tear.|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZB|100067526|02/02/2016|priority 3 |Q1|Unknown|Unknown|GC 175371 Leakage SCM (Statoil Gullfaks)|ATCO NOCO NOTE NOPT|Missing references in specification|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|100029564|20/06/2003|priority 3 |Q3|Unknown|Unknown|FAIL WITH BOM|NOPT NOTI NOCO ATCO|Design fault|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Engineering related|Design Specification/Drawing error
Q3|7102643|Unknown|priority 3 |Q3|Unknown|Unknown|Communication problems with SEM A|NOPT ATCO NOCO NOTI|Comms established/no fault found|103-Electrical|Modems/Communications|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOCO NOPT NOTI ATCO|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|P7000024191|16/10/2012|priority 1 |Q3|Unknown|Unknown|Check Valve não conforme.|NOPT NOCO NOTE ATCO|Sem evidência da causa|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Other causes/damage |Cause not found
ZF|P6000069056|02/11/2011|priority 3 |Q3|Unknown|Unknown|Missing HC61 on hyberbaric camber 3|NOPT NOTE NOCO|Forgot to close valve on test panel|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|P7000000897|19/10/2016|priority 1 |Q3|SHELL|Unknown|MMR - Change Over HP with reversed link|ATCO NOTE NOCO|Wire labels installed incorrectly.|TEST |Function|SS - Controls -SCM  hyd/mech components|Control Valve|Assembly |Improperly Installed
Q3|3812476|05/04/2000|priority 3 |Q3|Unknown|Unknown|SCM 18 damaged due to lifting method|ATCO NOCO NOPT NOTI|Correct lifting method was not used|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Lifting
ZF|P7000039672|23/01/2015|priority Unknown|Q3|Unknown|Unknown|Short-Circuit wires 261-262|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Intercompany|FMC Kongsberg
ZF|P7000016420|13/04/2012|priority 1 |Q3|Unknown|Unknown|Teste Long term não conforme.|NOPT NOCO NOTE ATCO|set up com defeito.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZE|P6000103208|19/09/2016|priority 3 |Q3|EXXONMOBIL|GOM|SCMDT  Julia #05  SEM short circuit|ATCO NOTE NOCO|Damaged during test. See RPT60139427|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Test |Incorrect Setup
ZF|7100320|24/11/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Mech. Interference of Grooved Pin|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000069056|29/09/2011|priority 3 |Q3|STATOIL|NORTH SEA|Wiring on PT 61A  Signal Crossed|NOPT NOCO NOTE|Wrong wiring against PT61  switched pair|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100018531|19/07/2013|priority 1 |Q3|Unknown|Unknown|Divergências Desenhos|ATCO NOTE NOCO NOPT|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|100020562|02/08/2010|priority 3 |Q3|BP|GOM|Mark all necessary ports on BPTH SCMs|NOTE NOCO NOPT|Unknown|Marking |No Marking|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|7105597|06/07/2010|priority 3 |Q3|PETRO SA; MOSSEL BAY|Unknown|Crude oil in the return system|NOCO NOTE NOPT|To be followed up with reason  SO1091305|Test Related |OBS-Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
Q1|7102643|13/10/2000|priority 2 |Q1|Unknown|Unknown|Water from HXT umb. jumper MQC plate L16|NOTI NOPT ATCO NOCO|No fault found|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Scarabeo-06|Initial/Direct product problem|Function
Q3|7101172|23/11/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000029772|07/09/2009|priority 3 |Q3|ENGIE|NORTH SEA|Fiber is twisted|NOPT NOTE ATCO NOCO|Wrong assembling of optic fiber|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|100018082|08/07/2002|priority Unknown|Q3|STATOIL|NORTH SEA|PT 32 AND 16 DEVIATE 15 BAR FROM ACTUAL|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-EFAT|Root cause Vendor|Material/Component error
ZF|P6000093498|04/08/2014|priority 3 |Q3|Unknown|Unknown|Water in Silicone sample|NOCO ATCO NOTE NOPT|SCM filled with contaminated silicone|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|PT adapter plate is loose|NOCO NOPT NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7102643|25/02/2000|priority Unknown|Q3|Unknown|Unknown|Åsg SCM 36  press. tested for only 14min|ATCO NOTI NOCO NOPT|Test print out shows 14 mins duration|101-Mechanical|Hydraulic Manifold Block|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P7000024900|07/11/2012|priority 1 |Q3|Unknown|Unknown|Fluido durante a coleta de silicone|NOTE NOCO NOPT ATCO|Unknown|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100056443|14/03/2011|priority 1 |Q3|EDISON/EDF|NORTH SEA|Pollution to Braico on EHXT and SCM.|NOTE NOCO|Incorrect set up/testing|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000077632|01/03/2015|priority 3 |Q3|Unknown|Unknown|No Xt-SCM test procedure for 615 SCMs|ATCO NOPT NOTE NOCO|Unknown|Documentation |Missing user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|P6000088604|12/08/2015|priority 1 |Q1|Unknown|Unknown|XT#06 SCM ACCUMULATOR LEAKAGE|NOPT NOCO ATCO NOTE|ACCUMULATOR N2 LEAK DURING TEST AT SS|Assembly Related |OBS-Physical Damage|Customer Compliant|Noncompliance to Customer Requirement|FMC Test |Tooling
ZF|P6000116166|27/10/2015|priority 3 |Q3|Unknown|Unknown|Screw got stuck|NOTE NOCO ATCO NOPT|Screw got stuck in threads|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|Vendor related |Assembly error
ZF|100067526|17/01/2018|priority 3 |Q3|Unknown|Unknown|External accumulator not within acceptan|ATCO NOTE NOCO|Gap between oil port and bottom plug|Assembly |Dimension (tolerance)|SS - Controls -SCM  hyd/mech components|Accumulator|Vendor related |Assembly error
ZF|P6000062454|08/09/2010|priority 2 |Q3|Unknown|Unknown|Config not released  Test files missing|NOTE NOCO NOPT ATCO|Unknown|Documentation |Procedure / Process Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Continuous Improvement
ZF|P6000088604|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000079433|01/10/2013|priority 3 |Q3|Unknown|Unknown|LP return on SCM|NOCO NOTE|Contamination inside check valve|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Test |Damaged during testing
ZF|P6000121268|17/09/2015|priority 3 |Q3|Unknown|Unknown|Leakage test outside criteria on FAT|NOPT NOTE NOCO ATCO|DCV leakage|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Specification not followed
ZF|7104033|05/03/2014|priority 3 |Q3|Unknown|Unknown|Incomplete GA DWG for SCM PN 7104033|NOCO ATCO NOTE NOPT|Incomplete GA DWG for Sygna SCM|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000064909|24/05/2011|priority 3 |Q3|Unknown|Unknown|Incorrect O-ring matnr:200005619|ATCO NOTE NOCO NOPT|Incorrect O-ring partnr in BOM|Design |Material Master Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100036936|15/10/2008|priority 3 |Q3|STATOIL|NORTH SEA|wireing list mess|ATCO NOPT NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|P6000100953|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7102643|21/09/2000|priority 2 |Q3|Unknown|Unknown|Fault message from SCM SEMA  well Y-4H|NOTI NOCO NOPT ATCO|SCM reset OK  no fault found|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|P6000055605|18/11/2014|priority 3 |Q3|Unknown|Unknown|Part issued without traceability.|NOTE ATCO NOCO NOPT|Equipment not asigned when picked|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZF|P7000000897|09/09/2011|priority 1 |Q3|SHELL|Unknown|Danos na área de vedação.|NOCO NOTE NOPT ATCO|UVDAL|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Packaging/Handling
ZF|100018082|24/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|not able to perform com test w.sand prob|ATCO NOCO NOTE NOPT|missing test equipment|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|7103233|15/06/2005|priority Unknown|Q3|SUNCOR|Unknown|SIO failure ?|NOTE NOPT NOCO|Not yet known (SCM still working subsea)|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Unknown|Unknown
ZF|100049000|06/12/2005|priority 3 |Q3|BP|GOM|UNSTABLE LEAKAGE ON OPEN AND CLOSE POS.|NOPT NOCO ATCO NOTE|Inappropriate test equipment.|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Other causes |Do Not Use
ZF|P6000055605|16/08/2011|priority 3 |Q3|SHELL|GOM|391V on AI input  AI 36 spare 9 is death|NOCO NOPT ATCO NOTE|Opr. failure  damage by wrong test setup|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P7000000897|07/06/2010|priority 1 |Q3|Unknown|Unknown|Center tube damaged SCM SN:10|NOPT NOTE ATCO NOCO|Center tube colapsed|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZE|P6000108542|02/02/2015|priority 2 |Q3|Unknown|Unknown|HFT60074760/E has mistake|ATCO NOTE NOCO|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|100033987|15/11/2006|priority 3 |Q3|STATOIL|NORTH SEA|El. rack applyed to high voltage|ATCO NOPT NOTE NOCO|Too high op. voltage applied  opr. error|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000001621|21/07/2015|priority 3 |Q3|PETROBRAS|Unknown|MMR - PT Broken|ATCO NOTE NOCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|Other el/opt components|FMC Assy |Damaged during assembly
ZF|100037965|22/03/2008|priority 1 |Q3|BP|Unknown|FPSO NCR 25 - SCM Failure|NOCO ATCO NOPT NOTE|Unknown|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOCO ATCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000105542|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7105128|12/03/2002|priority 3 |Q1|Unknown|Unknown|SCM's  Girassol  DH-gauges malfunction|ATCO NOTI NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Girassol FPSO|Initial/Direct product problem|Function
ZF|P6000057855|24/11/2010|priority 2 |Q3|ENI|Unknown|Software release document is missing|NOPT ATCO NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls -Computer system software|Basis 200e SW|FMC Engineering related |Procedure error
ZF|P7000001621|27/12/2010|priority 2 |Q3|Unknown|Unknown|Furações fora de centro|NOCO NOPT ATCO NOTE|Desalinhamento nas furações|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Purchasing related |Purchasing Error
ZF|100031223|02/07/2004|priority 3 |Q3|STATOIL|NORTH SEA|Missing document links in SAP.|NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100054943|09/01/2008|priority 2 |Q3|WOODSIDE|Unknown|Batch numbers missing in iBASE list|ATCO NOCO NOTE NOPT|approved with batch certification|Documentation |Incorrect Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|3794920|27/06/2000|priority 1 |Q3|Unknown|Unknown|Fluid leaking out of flush port (bleed)|ATCO NOTI NOCO NOPT|SCM tested  no fault found|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Leakage
ZF|100037966|13/04/2008|priority 2 |Q3|BP|Unknown|SCM changeover valve leaking subsea|NOCO NOTE ORAS ATCO|Unknown|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|P6000058949|18/11/2010|priority 3 |Q3|Unknown|Unknown|Placement of the nameplate in Outer Can|NOPT NOTE NOCO ATCO|Incorrect positioning of nameplates|Marking |Marking Location Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
ZB|7103234|06/11/2014|priority 2 |Q1|Unknown|Unknown|Warranty Claim for SCM 02I|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|P7000024900|06/09/2011|priority 1 |Q3|Unknown|Unknown|MRM test in QAM mode.|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000102554|10/04/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOPT ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000001621|25/03/2010|priority 1 |Q3|Unknown|Unknown|Falta de parafuso de fixação no anodo|NOCO NOPT ATCO NOTE|Itens faltantes|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000108542|07/02/2014|priority 3 |Q3|Unknown|Unknown|LP supply flowmeter leakage|NOPT NOTE NOCO ATCO|External leakage from flowmeter|Test Related |OBS-Leakage (Fluid)|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZB|100001156|24/08/2007|priority 4 |Q1|STATOIL|NORTH SEA|SCM6  GFC M-1H  SEMB Comm. failure|NOCO NOPT NOTE|Error in DHI board|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Other external causes |Unknown
ZF|P6000105542|09/01/2015|priority Unknown|Q3|Unknown|Unknown|NCR to Statoil - SCM manifold block|NOCO NOTE|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|P6000055605|02/12/2013|priority 3 |Q1|Unknown|Unknown|Bonga Claim 002 SCM 320|NOCO NOTE NOPT|Incorrect voltage destroyed SEMs|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|Other el/opt components|FMC Fabrication Shop Personnel |Improper Handling
ZF|P6000031350|24/01/2014|priority 3 |Q3|Unknown|Unknown|Equipment stored outside|NOTE ATCO NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - Electric Products|Distribution Module|FMC Other causes/damage |Planning error
ZF|7104670|25/08/2006|priority 4 |Q3|STATOIL|NORTH SEA|CIDV supply PT outside accept. criteria.|NOTE NOPT NOCO|Unknown|Assembly/Test Related |Function|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|FMC Assy |Missing Operation
Q3|7102643|Unknown|priority 3 |Q3|Unknown|Unknown|Computer was not configured for this SCM|NOPT ATCO NOTI NOCO|No configuration control against Bergen|Product defects for dept. 1640|1641/1642/1643/1644 Other|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Documentation
ZF|P7000039672|24/09/2014|priority 1 |Q3|Unknown|Unknown|Gland does not fit on Manifold Block|NOPT NOTE ATCO NOCO|1756 UVDAL MASKINFABRIKK A/S|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Final Inspection Error
ZF|P6000067533|08/01/2013|priority 1 |Q3|Unknown|Unknown|SCM Modules stored outside with no PSM|ATCO NOCO NOTE|Improper storage|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
ZB|P6000042969|23/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|SCM to be tested in a Tree|ATCO NOCO NOTE|Shipping delay of SCM|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000088604|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE NOPT ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000122574|19/08/2015|priority 2 |Q3|Unknown|Unknown|PT & valve cover|ATCO NOCO NOTE|BOM and drawing with new covers|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Continuous Improvement
ZF|P7000024191|04/04/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #20 - Can Bus & Serial Line|ATCO NOTE NOCO NOPT|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P1000018406|24/05/2013|priority 1 |Q3|Unknown|Unknown|DHFC will not hold pressure|NOTE NOPT NOCO|QN Cancelled|Damage |Damage during testing|SS - Controls - WOCS|Installation Workover Control System (IW|FMC Other causes/damage |QN Cancelled
ZF|100015538|18/12/2008|priority 2 |Q3|STATOIL|NORTH SEA|HFT on SCM has not been done|NOPT NOTE ATCO NOCO|HFT not performed|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|100006609|17/05/2013|priority 1 |Q3|PETROBRAS|Unknown|Hose House can't be assembled|ATCO NOPT NOCO NOTE|SCM MMR|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Maintenance
ZF|P6000109194|23/01/2014|priority 3 |Q3|Unknown|Unknown|4-20mA simulators not working.|NOTE ATCO NOCO NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|150/615 SW|FMC Engineering related |Engineering Error
ZF|7102969|02/05/2005|priority 3 |Q3|MOBIL EG|Unknown|Parts galling.|NOCO NOTE NOPT ATCO|Parts galling in assembly|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 08|NOTE NOCO ATCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|100049000|12/02/2016|priority 3 |Q2|Unknown|Unknown|Misalignment of the EC bolt holes|NOTE ATCO NOPT NOCO|Unknown|Machining Related |OBS-Hole Size Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|100049392|11/09/2013|priority 1 |Q3|Unknown|Unknown|Failed tank test/Silicone oil inside SEM|NOCO NOTE ATCO|Human error from operator and QA insp.|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q3|3794920|25/06/2002|priority 3 |Q3|STATOIL|NORTH SEA|Repair  ref. SN 30001253|NOCO NOPT NOTE|Unknown|101-Mechanical|Mechanical Components|Defect locations - onshore|KOS Kbg. SCM-Montasje|Root cause Other|Logistics-Packing/Shipping Damage
ZF|P7000000229|08/07/2013|priority 1 |Q3|Unknown|Unknown|High interference on the coupler thread|NOTE NOPT ATCO NOCO|1024 - NATIONAL COUPLING CO.  INC.|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Final Inspection Error
ZB|P6000055605|14/05/2014|priority 2 |Q1|Unknown|Unknown|Shell Perdidio Claim SCM 309|ATCO NOCO NOTE|Faulty Line coupler|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|Other el/opt components|Vendor related |Material error
ZF|P6000074156|09/11/2012|priority 3 |Q3|Unknown|Unknown|Serrated lock washer get squeezed|ATCO NOCO NOTE NOPT|Serrated washers removed from guide pin|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100049000|30/11/2010|priority 2 |Q3|BP|Unknown|Class 1 ECN 6083510|NOTE ATCO NOCO NOPT|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000104116|09/07/2014|priority 3 |Q3|Unknown|Unknown|damaged sealing surfaces|NOPT NOCO NOTE|Damage on sealing surfaces|Machining Related |OBS-Surface Finish Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
Q3|7102643|15/02/2000|priority 3 |Q3|Unknown|Unknown|PT for PMV not working  well Y3-H|NOCO NOPT NOTI ATCO|Refer to QN 200006649|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Function
ZF|P7000039672|01/09/2015|priority 1 |Q3|Unknown|Unknown|DHI doesn't communicate|NOPT NOCO NOTE ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Operator Error
ZF|100036936|08/01/2005|priority 1 |Q3|Unknown|Unknown|SCM NSAT - SW fault for CITV|ATCO NOPT NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|SO due to DC/DC Issue on AI 150 card|NOPT NOCO NOTE ATCO|Component Failure/Poor Workmanship|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZF|P6000039844|30/03/2009|priority 3 |Q3|SHELL|Unknown|24V OUT1 is too low on Sem A|NOCO NOPT NOTE|Procedure failure  to narrow  limits|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|P6000149536|26/01/2018|priority 1 |Q3|Unknown|Unknown|Talley plate contains wrong data|NOCO NOPT ATCO NOTE|Unknown|Marking |Marking content error|Object Types to Eng Matl CLASS|scm_assy|Vendor related |Specification not followed
ZB|100056261|29/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|SEM Common Alarm|NOCO NOPT NOTE ATCO|SEM Common Alarm|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Assy |Damaged during assembly
Q3|7100320|31/05/1999|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Hercules SCM 14|NOCO ATCO NOTI NOPT|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
Q3|7103233|19/11/1999|priority 2 |Q3|Unknown|Unknown|Install hydaulic flow restrictors|ATCO NOCO NOPT NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
Q3|7101172|05/09/2001|priority Unknown|Q3|STATOIL|NORTH SEA|Temp-sensor failure G-3H  GFA|NOPT NOCO NOTI ATCO|Not yet know  SCM subsea|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZD|100029062|07/10/2010|priority 1 |Q2|TOTAL|Unknown|SCM Issue|ATCO NOCO NOTE|Vendor Liability|Procurement |Vendor did not complete required work|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000074855|13/02/2012|priority 3 |Q3|Unknown|Unknown|Girry 1 do not appear in ST config|ATCO NOCO NOPT NOTE|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 08  Bytting av solenoider|NOCO NOPT NOTE ATCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
Q1|7101172|22/04/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 03 GFA/K-2H SIO scanning failure|NOTI NOCO ATCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7102643|01/11/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|100033987|20/08/2004|priority 3 |Q3|STATOIL|NORTH SEA|FAIL WITH OUTER CAN|NOCO ATCO NOPT NOTE|Unknown|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Engineering related|Design Specification/Drawing error
ZF|100048038|09/10/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|Cleanliness  General|NOCO NOPT NOTE ATCO|Failure to clean inside of the outer can|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
ZF|100052701|03/04/2014|priority 2 |Q3|Unknown|Unknown|No communication w. MPFM|NOCO NOPT NOTE ATCO|Not able to upload correct SW|Test Related |OBS-Test Omitted|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZB|7101401|23/05/2003|priority 3 |Q1|PETROBRAS|Unknown|SCM 2 Marlim El-can A malfunction|NOTE NOCO NOPT|Unknown|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Assembly/Test related|Assembly/Test error
ZF|3812476|08/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|Missing documentation from receiving|ATCO NOTE NOCO|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
Q3|100001156|29/03/2001|priority 2 |Q3|STATOIL|NORTH SEA|TRANSPORTSKADE PÅ SCM OG SKID|NOPT ATCO NOCO NOTI|Uforsvarlig truckkjøring|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen goods receipt/inspection|Root cause Other|Logistics-Packing/Shipping Damage
ZB|P6000043122|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM SSS 01|NOTE ATCO NOPT NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000107991|22/04/2014|priority 3 |Q3|Unknown|Unknown|Gauge Timeouts|NOCO NOPT NOTE ATCO|Follow-up in QN 200376395|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Clarification
ZE|P6000076121|24/08/2011|priority 3 |Q3|Unknown|Unknown|CITV  no connection with module/ST|NOTE NOCO ATCO|Documentation error|Test Related |OBS-Component Error|SS - Controls - Test and Transportation|Sensor Simulator (SESI)|Projects Related|Documentation error
ZF|P6000069056|22/06/2011|priority 3 |Q3|STATOIL|NORTH SEA|El schematic wrong description for TCSA|NOPT NOTE ATCO NOCO|Comments in El Schematic now corrected|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100017278|28/05/2004|priority 3 |Q3|STATOIL|NORTH SEA|SILICON OIL IN THE BLADDER COMPENSATOR|ATCO NOPT NOCO NOTE|Hydrogen embrittlement. (Broken bolts.)|Vendor related|Unknown|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|Vendor related|Material error
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Bytting transusere.|NOCO ATCO NOPT NOTE|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000119335|28/11/2013|priority 3 |Q3|Unknown|Unknown|To short threads in outercan|NOTE NOPT NOCO|Interface with EC adapter not verified|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
ZD|P6000084242|08/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PARTNUMBER|NOTE ATCO NOPT NOCO|INCORRECT PARTNUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000126219|28/09/2016|priority 3 |Q3|Unknown|Unknown|Silicone contamination after hyperbaric|NOTE NOPT NOCO ATCO|Test connection not according to SPC|TEST |Leak|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZE|P6000088751|06/06/2016|priority 3 |Q3|Unknown|Unknown|Update FAT GWF-2 scm|NOCO ATCO NOPT NOTE|TST60081959 rev.H updated and released|Unknown|Unknown|SS - Controls -SCMMB|Other mechanical components|QA/QS/QI Related|Documentation error
ZF|P7000020444|12/08/2011|priority 1 |Q3|Unknown|Unknown|Hyperbaric chamber test failed|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls - Test and Transportation|Test & Flushing Plate|Vendor related |Tooling
ZE|P6000105708|06/11/2013|priority 3 |Q3|Unknown|Unknown|Forbedringer på Julia SRM|ATCO NOTE NOPT NOCO|Drawing  BOM and procedure update|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|100020562|26/05/2004|priority 3 |Q3|BP|GOM|Sand Detector Simulator is not working|NOCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7104033|07/05/2007|priority 3 |Q3|STATOIL|NORTH SEA|Possible leak on return compensator|NOTE NOCO|Operator misunderstood function.|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Intervention - Running Tool|SCM Running Tool|Vendor audit related|Unknown
ZF|P7000016420|02/06/2011|priority 1 |Q3|PETROBRAS|Unknown|Falha no flowmeter de retorno LP.|NOTE NOCO NOPT ATCO|Flow Meter Inoperante|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|P6000105708|11/10/2015|priority 2 |Q3|EXXONMOBIL|Unknown|SRM bladder Ruptured|NOCO NOTE|SRM stored outside topped up|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Damaged during installation
ZF|7103233|04/01/2012|priority 2 |Q3|SUNCOR CPI|Unknown|Material not delivered to plant|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|100031223|19/04/2005|priority 3 |Q3|STATOIL|NORTH SEA|Damaged tronic el-connector.|NOTE NOCO|Assembly / handling error.|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Variance|Unknown
ZF|P6000055605|20/09/2013|priority 3 |Q3|Unknown|Unknown|Child QN Valves not stroking On XT #8 .|NOPT NOCO NOTE ATCO|Valves not stroking|FMC Other Defect |Functional|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Other causes/damage |Cause not found
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|Missing sign offs|NOPT ATCO NOTE NOCO|missed sign off|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Documentation error
ZF|P7000000897|11/06/2012|priority 1 |Q3|SHELL|Unknown|Difficulty to remove screws.|NOCO NOTE ATCO NOPT|SCM MMR|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|Other external causes |Customer Error/responsibility
Q3|100006360|04/04/2000|priority Unknown|Q3|Unknown|Unknown|SCM 03  wrong type of flow restrictor|NOPT ATCO NOCO NOTI|Unknown|101-Mechanical|Hydraulic Manifold Block|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Dimension
ZF|100035013|23/01/2006|priority 2 |Q3|SHELL|Unknown|Problem operating MDV on XT|NOTE NOCO NOPT ATCO|"Incorrect ""blind plate"" assembled"|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZD|P6000039844|16/02/2009|priority 1 |Q2|SHELL|Unknown|(SS) DEFECT IN SEM B DURING TESTING|NOCO NOTE NOPT|Damaged electrical component   op.ampl|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
ZF|100049392|02/07/2013|priority 2 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOTE NOCO NOPT ATCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZB|100031223|19/04/2005|priority 2 |Q1|STATOIL|NORTH SEA|Damaged tronic el-connector.|NOPT NOTE NOCO|Assembly / handling error.|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000068912|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100058509|03/08/2011|priority 2 |Q3|LLOG|GOM|Error in ETU Trending|ATCO NOTE NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Engineering related |Engineering Error
ZE|P6000091085|13/05/2016|priority 4 |Q3|Unknown|Unknown|OWIRS Deadman sequence|NOPT NOCO NOTE|QN Cancelled|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Documentation
ZF|P7000039672|03/07/2013|priority 1 |Q3|Unknown|Unknown|ERRO NA APLICAÇÃO DE TORQUE|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Operator Error
Q1|7102643|05/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 03 ÅsgA G-3H HP ret. valve Blocked|NOCO NOTE ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Damages
ZB|100038200|11/09/2006|priority 1 |Q1|SHELL|Unknown|Unable to lock SCM to tree.|NOPT NOCO NOTE|wrong documentation|Documentation |Incorrect user documentation (customer)|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Manufacturing related |Tooling Error
ZF|7103233|19/05/2007|priority 3 |Q3|OVERALL PROJECT ROLL-UP|Unknown|Poor sound in SCM|NOTE NOPT NOCO|see SN 300162766|FMC Other Defect |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZB|100035118|08/01/2016|priority 3 |Q1|Unknown|Unknown|WEL  Test Failure  L1 Escape|ATCO NOCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000068902|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|21/12/2018|priority 1 |Q3|Unknown|Unknown|SEM COMUNICAÇÃO DHI A|NOCO ATCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZF|7101401|31/03/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Outer Can Base Screw Holes|NOPT ATCO NOCO NOTE|Unknown|Machining Related |OBS-Position Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Machine Shop Personnel |Operator error
ZF|P7000000897|31/05/2010|priority 1 |Q3|Unknown|Unknown|lock mechanism blocked|NOCO NOTE ATCO NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Damaged during assembly
ZF|100025661|29/03/2006|priority Unknown|Q3|PETROBRAS|GOM|Deviation from BOM  Cottonwood - SCM 1|NOCO NOPT NOTE ATCO|SCM deviation of LP and HP valves|Change/Deviation Request |Part substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000028371|26/05/2008|priority 3 |Q3|SHELL|GOM|Batch numbers missing in iBASE list|NOPT NOTE NOCO|Change: batch cert. to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|100055600|01/06/2010|priority 2 |Q3|REMINGTON OIL AND GASHOUSTON STOCKING SCM MK II (15K)|Unknown|SCM ASSY|NOTE NOCO NOPT|lack of process understanding.|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|QA/QS/QI Related|Final Inspection error
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|Rosa 401 invalid pressure sensor reading|NOCO NOTE|Unknown|FMC Other Defect |Unknown|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Unknown
ZF|P7000001843|16/10/2012|priority 1 |Q3|Unknown|Unknown|Mexilhão #08 - Avaria após Hiperbárico|NOPT NOCO ATCO NOTE|MMR SCM|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Test |Damaged during testing
ZF|P6000102554|18/11/2013|priority 3 |Q3|Unknown|Unknown|EC7 pin 11 and 12 wired wrong|ATCO NOPT NOTE NOCO|Eng. error in wiring list LST60095676|Design |Drawing Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Engineering Error
ZF|100037966|23/01/2008|priority 2 |Q3|BP|Unknown|Incorrect results on SEM B card|NOPT NOTE NOCO ATCO|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
Q3|100006609|12/03/2001|priority 3 |Q3|PETROBRAS|Unknown|Leak of silicone oil from comp. bladder|ATCO NOTI NOCO NOPT|Too much silicone - filling PRD changed|102-Hydraulic|Accumulators|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Leakage
ZF|P7000024900|28/08/2013|priority 1 |Q3|Unknown|Unknown|Scratch inside of the Outer Can|ATCO NOCO NOTE NOPT|101545 - KRISTIANSANDS SKRUEFABRIKK|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Damage during transport
ZF|P6000093501|31/10/2012|priority 3 |Q3|Unknown|Unknown|outcan is not coret thread|NOTE ATCO NOPT NOCO|Bad threads for EC slot on outercan|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000125394|25/08/2015|priority 3 |Q3|Unknown|Unknown|Check valve not in drawing.|NOTE NOCO ATCO|Check valve missing in part BOM|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZB|P6000063531|03/05/2017|priority 2 |Q1|Unknown|Unknown|Vigdis OH19 Power supply error|NOTE NOCO ATCO|High Voltage during testing|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIII|FMC Test |Damaged during testing
ZF|P7000039672|03/11/2014|priority 1 |Q3|Unknown|Unknown|Relief valve sem marcação|NOTE NOPT ATCO NOCO|134871 - Pall do Brasil Ltda|Marking |No Marking|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P7000000897|09/03/2012|priority 1 |Q3|Unknown|Unknown|SEM Review|NOPT NOTE ATCO NOCO|delay in delivering for workshop test|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Purchasing related |Purchasing Error
ZF|P6000104111|10/03/2014|priority 3 |Q3|Unknown|Unknown|Smarttool config|NOCO ATCO NOTE NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P7000008275|11/06/2010|priority 2 |Q3|Unknown|Unknown|Falha na leitura do PDG da SEM A|NOPT ATCO NOCO NOTE|Falha de comunicação|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|7101463|08/09/2010|priority 3 |Q3|EXXONMOBIL|Unknown|Missing Sign-offs|ATCO NOTE NOCO NOPT|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000055605|25/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SEM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7104670|06/11/1999|priority 2 |Q3|Unknown|Unknown|HNF SCM 05|NOTI NOCO ATCO NOPT|Unknown|Product defects for dept. 1640|1641 Test equipment|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
ZF|P7000016420|19/11/2010|priority 1 |Q3|Unknown|Unknown|Tubo de Vácuo|NOPT NOCO NOTE ATCO|Unknown|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOTE NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZE|P6000084242|10/10/2013|priority 4 |Q3|Unknown|Unknown|SEM A failure to communicate with SPCTU|ATCO NOCO NOTE NOPT|Communication failed|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000058949|02/09/2010|priority 2 |Q3|Unknown|Unknown|Communication Problem SEM A|NOPT NOCO NOTE|Follow-up covered by QN200182969|Test Related |OBS-Function|SS - Controls - Electronic Boards|Comm.link (Power line)|Vendor related |Clarification
ZF|P6000042968|03/04/2010|priority 1 |Q3|TOTAL|WEST AFRICA|Flow meter not responding during HFT|NOTE NOPT ATCO NOCO|Flowmeter returned to vendor|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZE|P6000088604|11/08/2015|priority 4 |Q3|Unknown|Unknown|(CDM) Missing API bucket for SCM|NOPT NOTE NOCO ATCO|Missing API bucket for SCM|FMC Other Defect |Part Lost|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZF|P6000029772|10/09/2009|priority 1 |Q3|ENGIE|NORTH SEA|OC2 and OC3 fiber dirty|NOPT NOCO NOTE ATCO|Damaged connector|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|100026567|08/01/2007|priority 3 |Q3|Unknown|Unknown|CITV not working properly|NOCO NOPT NOTE ATCO|Human error when modifying wiring|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Assy |Operator Error
Q3|7100320|02/12/1999|priority 3 |Q3|Unknown|Unknown|Upgrade Hercules SCM 12-GAMA to 12-OMEGA|NOTI NOCO NOPT ATCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOPT NOTI ATCO NOCO|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|100048038|12/09/2007|priority 2 |Q3|AGBAMI|Unknown|Exposed Electrical Connector|NOTE NOPT NOCO ATCO|NO NON-COMPLIANCE|Design |DBI Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P7000001843|14/10/2011|priority 1 |Q3|Unknown|Unknown|Outer Can|NOCO NOPT ATCO NOTE|Amasso na Outer|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000104111|28/04/2014|priority 4 |Q3|Unknown|Unknown|No power to DIU from SEM B|NOTE NOPT NOCO|Wire not connected to earth bar|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
Q3|7104670|20/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  flowmeters HP+LP read too high|ATCO NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZB|7104075|25/10/2006|priority 2 |Q1|Unknown|Unknown|PMV malfunction.|NOTE NOCO|Pressure sensor malfunction.|Assembly/Test Related |Interface of components issue|X-mas Tree|Production Master Valve (PMV)|Vendor related |Component error
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|Shell SCM Communication problem|NOPT NOCO NOTE ATCO|Vendor changed colors on wires|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Shell Alliance GOM|Root cause Vendor|Assembly/Fabrication/Test error
Q3|7102643|09/10/2000|priority 2 |Q3|Unknown|Unknown|LP supply PT stuck at 316 bar  well N-4H|NOCO ATCO NOTI NOPT|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|7102969|21/10/2005|priority 3 |Q3|Unknown|Unknown|Procedure incorrect for RIT of Megi SCM|NOPT NOTE ATCO NOCO|TST DOCUMENT DISCREPANCY|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|100025661|01/07/2013|priority 3 |Q3|Unknown|Unknown|Docs/Shell/SCM/PN and Docs Don't Match|ATCO NOCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
Q1|7104422|Unknown|priority 2 |Q1|Unknown|Unknown|SCM HFT test procedures are missing|NOTI NOPT ATCO NOCO|KOSKBG have not sent procedures|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Problem causes  defect causes|Maintenance
Q1|7103234|22/05/2002|priority 3 |Q1|SUNCOR CPI|Unknown|SCM PT DHSL function has +25bar offset|NOPT NOCO NOTI|PT malfunction/cause not yet known|103-Electrical|Pressure Transducer|Defect locations - offshore/field|FPSO Terra Nova|Initial/Direct product problem|Function
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Replacement of solenoids (upgrade)|ATCO NOTE NOPT NOCO|Internal aluminium washers were fitted|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|100058509|03/08/2011|priority 2 |Q3|LLOG|GOM|Trending errors in LLOG ETU|NOTE NOCO|Cancelled duplicate as SN 300280430|Test Related |OBS-Function|SS - Controls - Topside Products|Other Topside Products|FMC Other causes/damage |QN Cancelled
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO NOPT ATCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000024191|02/05/2013|priority 1 |Q3|Unknown|Unknown|Spacer não monta / Spacer does not fit|NOTE NOCO ATCO NOPT|104327 - FAITH MFG. CO. INC.|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|100037965|12/04/2010|priority 3 |Q3|BP|Unknown|Software error.|NOPT NOCO NOTE|DH card  configuration update|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|P7000039672|25/10/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Screw/Securing Plate from El. Can|NOPT NOCO NOTE ATCO|Improper handling of tool|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Improper handling
ZE|7104670|24/05/2016|priority 2 |Q3|Unknown|Unknown|Lack of config file during maintenance|DLFL NOCO|Unknown|Unknown|Unknown|SS - Controls -Computer system software|ETU SW|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000068912|29/06/2011|priority 3 |Q3|Unknown|Unknown|GAS PRECHARGE PORT REMOVE FROM DRAWING|NOPT NOTE ATCO NOCO|ECN change  during assembly|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Operator Error
Q3|7101172|02/11/1999|priority 3 |Q3|Unknown|Unknown|PT/TT upstream choke. H-1H|NOTI ATCO NOPT NOCO|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
Q3|7101172|02/11/1999|priority 3 |Q3|Unknown|Unknown|GFS SCM 14  LP supply leak on Well H-1H|NOPT NOTI ATCO NOCO|Wrong fluid (Castrol GF30) used|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Gullfaks A|Root cause Other|Customer-Customer error
ZF|100017997|18/08/2006|priority 3 |Q3|Unknown|Unknown|SCM In-House FAT  wrong fluid used|ATCO NOTE NOCO NOPT|failure to follow project procedure|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000074156|08/10/2012|priority 3 |Q3|Unknown|Unknown|PT 18 show no value when using SEM B|NOCO NOTE NOPT|Label on wires incorrect from supplier.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|Vendor related |Specification not followed
ZF|100030542|30/03/2006|priority 2 |Q3|BAOBAB|Unknown|FNCR RAISED FOR CNR Baobab SCM|NOCO NOPT ATCO NOTE|Cause not yet known  see SN300088479|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Unknown|Unknown
ZD|100020562|12/08/2010|priority 3 |Q2|Unknown|Unknown|Tool Mark|NOTE ATCO NOPT NOCO|Tool Mark|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZE|P6000068902|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update SCM PSM - Luanda Workshop|NOCO NOTE|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|100067526|01/10/2012|priority 2 |Q3|Unknown|Unknown|Gullfaks 7 DBA Drwaing|NOPT NOCO ATCO NOTE|Bom and drawing error.|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|7104670|27/02/2004|priority 3 |Q3|STATOIL|NORTH SEA|SCM 10 Heidrun SIO SEM A malfunction|NOCO NOTE NOPT ATCO|expected unauthorized voltage at input|Damage |Damage during testing|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Other causes |Do Not Use
ZF|7101401|05/11/2015|priority 1 |Q3|Unknown|Unknown|Ângulo do Bisel|NOCO NOPT ATCO NOTE|angulo do bisel|Welding related |Miscellaneous|SS - Controls -SCM Dummy/SCMMB Test & Fl|Outercan|FMC Fabrication Shop Personnel |Operator error
ZF|P6000079032|29/08/2016|priority 3 |Q3|Unknown|Unknown|CR Unable to perform test accord to HFT|ATCO NOTE NOCO NOPT|CR issued to customer  lack of test eq.|TEST |Missed Operation|SS - Controls -Instrumentation|Other SCM instruments|FMC Other causes/damage |Cause not found
ZB|P6000042968|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 15|NOTE ATCO NOPT NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P6000105542|07/11/2013|priority 3 |Q3|Unknown|Unknown|Error on drawing|ATCO NOCO NOTE NOPT|Dwg is correct  QN cancelled|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOPT NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|100037966|20/10/2006|priority 1 |Q3|BP|Unknown|Malfunctioning  receiving test.|NOTE ATCO NOPT NOCO|Test procedure correction|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|100037966|06/04/2005|priority 3 |Q3|Unknown|Unknown|Top of SCM  marking is too big|NOCO NOPT ATCO NOTE|Drawing error|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
Q1|7102969|03/03/2003|priority 3 |Q1|Unknown|Unknown|Failure on SEM A|NOCO NOTE NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Work Shop|Initial/Direct product problem|Function
Q3|7100320|Unknown|priority Unknown|Q3|Unknown|Unknown|Oppgrader Hercules 05-BETA til 05-OMEGA|NOPT ATCO NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|22/12/2015|priority 1 |Q3|Unknown|Unknown|Tygn Hose com diametro maior|NOTE ATCO NOCO NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Final Inspection Error
ZB|P6000039844|13/08/2009|priority 1 |Q1|SHELL|Unknown|Rust appeared at SCM top plate area|NOPT NOCO NOTE|Follow up in QN 200136409|Coating/Plating |Coating defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100037427|15/03/2005|priority 2 |Q3|TOTAL|WEST AFRICA|Wrong readings detected during EFAT|ATCO NOCO NOPT NOTE|Unknown|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL ATCO NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P7000024191|10/07/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|ATCO NOCO NOPT NOTE|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000001621|13/08/2010|priority 1 |Q3|Unknown|Unknown|Fechamento da outer can Hercules 03|ATCO NOCO NOPT NOTE|Interferencia mecanica nos filtro|Assembly Related |OBS-Interface issue|SS - Compl. & W.Over - XT - General|Horizontal Penetrators|FMC Engineering related |Engineering Error
ZB|P7000000897|08/05/2015|priority 4 |Q1|SHELL|Unknown|BC-10 - Fail to Unlock SCM #12|NOTE ATCO NOCO|Lack of preservation procedures|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Other external causes |Customer Error/responsibility
ZB|100033987|15/11/2004|priority 2 |Q1|Unknown|Unknown|ÅsgBB84 VO-01 Prep SCM assy|ATCO NOPT NOTE NOCO|Unknown|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000042969|25/11/2010|priority 2 |Q3|Unknown|Unknown|Feil plukk av hydralic  plug hex hea|NOPT NOTE NOCO|Picking fault in warehouse|FMC Other Defect |Part Lost|SS - Controls -SCMMB|Other hydraulic components|Intercompany|FMC Kongsberg
ZF|P7000024191|04/10/2012|priority 1 |Q3|Unknown|Unknown|Protection ring Ovalizada|NOTE ATCO NOPT NOCO|Peça ovalizada|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P6000063531|10/01/2019|priority 2 |Q3|Unknown|Unknown|SEM  SEM's damaged by P6000067816 at EC4|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7102643|16/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 13 ÅsgA L-1H PT Func. line 11 malfun|NOCO NOTI ATCO NOPT|Unknown|202-Electrical/Sensor equipment|Pressure/Temperature Transmitters|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZF|P7000016420|14/10/2011|priority 1 |Q3|Unknown|Unknown|fio do conector está mordido|NOTE NOPT NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000064911|31/05/2018|priority 1 |Q3|Unknown|Unknown|Cust. Dev. - S3 Work Omitted|NOCO NOTE ATCO|Unknown|Change/Deviation Request |Process substitution request|Object Types to Eng Matl CLASS|scm_running_tool|FMC Other causes/damage |Planning error
Q3|7103234|19/11/1999|priority 2 |Q3|Unknown|Unknown|Install hydaulic flow restrictors|NOPT NOTI NOCO ATCO|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Function
ZF|100038200|24/07/2006|priority 3 |Q3|LLOG|GOM|CANNOT PERFORM HFT SECTION|NOCO ATCO NOTE NOPT|no  CITV Simulator identified|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
Q3|7104075|10/10/2000|priority 2 |Q3|Unknown|Unknown|SCM requires DHI-108 card modification|NOTI NOPT NOCO ATCO|Unknown|103-Electrical|DHI Interface|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q1|100017278|21/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 56 ÅSG LP Acc. leak. in top|NOCO NOPT NOTI|Unknown|102-Hydraulic|Accumulators|Defect locations - onshore|KOS Bergen workshop|Root cause Vendor|Design error
ZF|P6000042969|27/04/2011|priority 2 |Q3|TOTAL|WEST AFRICA|Wrong coulor on the outer can|NOTE NOPT NOCO|Qn cancelled.Use as is|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |QN Cancelled
Q3|100018600|18/03/2003|priority Unknown|Q3|PETROBRAS|Unknown|B electronic seems to fail|NOTI NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
Q2|7101172|05/03/2001|priority 3 |Q2|Unknown|Unknown|SCM DHPT  data transmission stopped|NOCO NOTE ATCO NOPT|Down Hole gauge - Roxar's problem|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOCO NOPT NOTE ATCO|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZD|100020278|28/09/2015|priority 3 |Q2|Unknown|Unknown|Outer Can Coating|ATCO NOTE NOCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|100049000|18/07/2011|priority 2 |Q3|BP|GOM|Dial caliper coupler measurements|ATCO NOCO NOTE NOPT|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100017305|08/04/2003|priority Unknown|Q3|Unknown|Unknown|Olje går ikke mellom filter|NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100030542|14/02/2006|priority 3 |Q3|CNR|Unknown|FNCR D01083 Raised on Baobab|NOTE ATCO NOPT NOCO|Handling at airport|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100056176|11/06/2008|priority 3 |Q3|STATOIL|NORTH SEA|Batch numbers missing|NOCO NOTE|QC change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|100034629|21/10/2005|priority 3 |Q3|STATOIL|Unknown|CHANNEL 1 AND 5 IS WRONG MARKED|NOPT NOCO NOTE ATCO|Incorrect marking of connector.|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100030711|01/04/2004|priority 2 |Q3|STATOIL|Unknown|Switched outercan between SCM13 & SCM14|NOTE ATCO NOCO NOPT|Unknown|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Assembly/Test related|Operator error
ZF|P7000020444|18/07/2011|priority 1 |Q3|Unknown|Unknown|Penetrador näo monta.|NOCO NOPT ATCO NOTE|impossibilidade de realizar dimensional|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|Opt. Connector|FMC Other causes/damage |Cause not found
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|SO due to DC/DC Issue on AI150 card|NOCO NOPT NOTE ATCO|Component Failure/Poor Workmanship|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
Q1|7105129|28/02/2003|priority 3 |Q1|TOTAL|Unknown|SCM 2I GIR communication problems SEM B|NOPT ATCO NOTI NOCO|Unknown|103-Electrical|SEM El.Rack|Ext. Loc. - Luanda (Angola)|Work Shop|Initial/Direct product problem|Function
ZF|P7000039672|25/10/2013|priority 1 |Q3|Unknown|Unknown|Vazamento na adapter plate de LP PS#17|NOTE NOPT ATCO NOCO|123643 - BOSCH REXROTH  LTDA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZF|P6000068924|16/11/2011|priority 1 |Q3|TOTAL|Unknown|Wrong use of miniseal|NOCO NOTE NOPT|Error in PRD. follow up in QN200232669|Design |Procedure Error|SS - Controls -SCM el/opt components|SCM Wiring|FMC Engineering related |Procedure error
ZB|100048038|03/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|SCM #20 SEM A FAILURE (No Comms)|NOCO NOTE|SCM #20 SEM A FAILURE (No Comms)|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Processor PCBs|FMC Other causes/damage |Cause not found
ZF|P6000079032|27/04/2012|priority 3 |Q3|STATOIL|NORTH SEA|Communication error PSD|NOCO ATCO NOPT NOTE|Investigation & Follow-up in QN200265826|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Vendor related |Clarification
Q3|3812476|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM to be repaired|NOCO NOTI NOPT ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Function
Q3|7102643|24/08/2001|priority 2 |Q3|Unknown|Unknown|Locking mechanism lacks xylan|NOCO NOPT NOTI ATCO|Unknown|101-Mechanical|Locking Mechanism|Defect locations - onshore (HES)|Kongsberg SCM-126A/B|Initial/Direct product problem|Coating
ZF|100048038|12/04/2007|priority 2 |Q3|AGBAMI|Unknown|LP pressure changes AGB SN 25|NOCO NOTE NOPT ATCO|New requirements from customer|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|7103233|11/05/2007|priority 2 |Q3|Unknown|Unknown|Low flow|NOPT NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Unknown
ZB|P6000098616|17/10/2013|priority 3 |Q1|Unknown|Unknown|Stones Claim  SCM #421|NOTE ATCO NOCO|Earthing of CPU card missing|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Engineering Error
ZF|7102643|06/07/2011|priority 1 |Q3|STATOIL|NORTH SEA|Fluenta sanddetector not working|NOTE NOCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|100052701|11/11/2010|priority 3 |Q1|STATOIL|NORTH SEA|B&B Damaged SCM receptacle|NOCO NOTE NOPT|Incorrect jumper installed.|Damage |Damage Due to Handling|Customer Compliant|Noncompliance to Customer Requirement|FMC Other causes/damage |Planning error
ZF|3812476|04/07/2007|priority 3 |Q3|STATOIL|NORTH SEA|Had to modify SCM to secure it in skid|NOPT NOTE NOCO|Bad planning during mob|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Planning error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOCO NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000105708|19/02/2014|priority 4 |Q3|Unknown|Unknown|OC wiring fault|NOCO NOTE NOPT|Wiring error during outercan closing|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000039844|22/08/2018|priority 3 |Q3|Unknown|Unknown|Missing test equipment / CR request|ATCO NOPT NOTE NOCO|Unknown|Electrical |Other- Specify in comments|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Incorrect set up/testing
ZF|P6000104116|21/10/2014|priority 3 |Q3|Unknown|Unknown|Sealing surface not within accept crit|NOTE NOPT NOCO ATCO|Seling surface outside of accep. crit.|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZE|100018531|16/01/2017|priority 3 |Q3|SHELL|Unknown|MMR - EC4 Assembly without O-ring|NOTE ATCO NOCO|Unknown|Assembly |Missing Components|SS - Controls -SCM el/opt components|El. Connector|Causes for Improvement|Process/Procedure Not Being Followed
ZD|7101463|29/01/2015|priority 3 |Q2|Unknown|Unknown|Damage to the ROV bucket bore area|ATCO NOCO NOTE NOPT|Unknown|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|P6000093498|04/03/2014|priority 4 |Q3|Unknown|Unknown|FM  verification of assembly|NOTE ATCO NOCO|FM  verification of assembly|Assembly Related |OBS-imension (tolerance)|SS - Controls -Instrumentation|SCM Flowmeter|FMC Engineering related |Engineering Error
ZF|100054943|12/03/2008|priority 2 |Q3|WOODSIDE|Unknown|(SS) SCM NOT FULLY UNLOCKED|NOPT NOTE NOCO|CONTROLS TECHNICIAN ERROR|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
Q3|7104670|03/02/2000|priority 3 |Q3|Unknown|Unknown|Fargemerkning av topp og side på S/N 04|NOPT NOTI ATCO NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Marking
Q1|7104075|27/12/2000|priority Unknown|Q1|Unknown|Unknown|COntrol Valve failure|NOCO NOPT ATCO NOTE|See FNCR|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Shell Alliance GOM|Root cause Engineering|Other Product Design error
ZF|100038200|20/02/2006|priority 1 |Q3|Unknown|Unknown|SCM POWER INSUFFICIENT TO POWER SKOFLO|NOPT NOTE NOCO ATCO|High inrush current need in SKOFLOsensor|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|3794920|29/01/2004|priority 2 |Q3|STATOIL|NORTH SEA|Mob SCM SSP 37 Statfj F&D 18           *|NOPT NOTE ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000042968|13/05/2009|priority 1 |Q3|Unknown|Unknown|Cards fails to read gauges|NOCO NOPT NOTE|Error to be confirmed in QN200128479|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Unknown
ZF|P6000090632|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO NOPT|No SEM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7104075|05/11/2001|priority Unknown|Q1|Unknown|Unknown|Silicone oil leaking from SCM  offshore|NOTI NOCO NOPT|SCM compensator bladder damaged|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|Customer goods receipt|Initial/Direct product problem|Damages
ZF|P7000008275|28/05/2012|priority 1 |Q3|Unknown|Unknown|Revestimento / Roscas danificadas|NOTE NOPT NOCO ATCO|Peça no estoque por muito tempo|Falta de revestimento|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Damage from Wear and Tear
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOTE NOPT NOCO ATCO|Dial caliper coupler measurements|Machining Related |OBS-Angle error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZB|100031223|16/06/2004|priority 3 |Q1|STATOIL|NORTH SEA|SEM adress on SCM not identified|NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100049000|22/03/2006|priority 2 |Q3|BP|GOM|Incorrect part number|NOTE NOPT NOCO ATCO|Receiving Insp. Error|Change/Deviation Request |Part substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |QA/QS/QI error
Q3|7106268|25/10/2000|priority Unknown|Q3|Unknown|Unknown|SCM I/DHI 04|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. X-mas tree/FCM workshop|Initial/Direct product problem|Function
ZF|100050383|30/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|Problems with SEM outercan assembly|ATCO NOCO NOPT NOTE|Marginal design|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes |No Non-Compliance
ZF|P6000042968|13/05/2009|priority 1 |Q3|TOTAL|WEST AFRICA|Cards fails to read gauges|NOTE NOCO NOPT|Error to be confirmed in QN200128479|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Unknown
ZF|100049000|19/07/2011|priority 3 |Q3|BP|Unknown|Dial caliper coupler measurements|NOTE NOPT ATCO NOCO|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100046112|21/06/2013|priority 2 |Q3|Unknown|Unknown|Possible CPU and AI failure|NOCO ATCO NOPT NOTE|Cause not yet found  cards to be invest.|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Vendor related |Clarification
ZF|100036936|22/11/2007|priority 2 |Q3|STATOIL|NORTH SEA|HFT not performed|NOPT ATCO NOTE NOCO|Due to lack of time|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|7104670|26/02/2014|priority 3 |Q3|Unknown|Unknown|Misguiding information in TPR-0011175|ATCO NOCO NOTE|Misguiding information in TPR-0011175|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZE|P6000069820|28/08/2015|priority 4 |Q3|Unknown|Unknown|(CDM)SCM has lost its redundancy|NOTE ATCO NOCO|Bad Sensor Values|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|7102969|26/05/2005|priority 3 |Q3|Unknown|Unknown|SCM UNFIT FOR USE AS SPARE/REPLACEMENT|NOCO NOPT ATCO NOTE|LP hyd. over pressured during testing|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|100037966|16/12/2005|priority 3 |Q3|BP|Unknown|SCM hydaulic cleanliness out of spec.|ATCO NOTE NOPT NOCO|SCM contaminated by external equipment|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100016901|05/01/2004|priority 3 |Q3|BP|GOM|PT failure|NOPT NOTE NOCO|Unknown error. It may be a PT error.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Operation/maintenance related |Expected wear and tear
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|NOCO ATCO DLFL|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZB|P6000043122|03/08/2013|priority 2 |Q1|TOTAL|WEST AFRICA|SCM Fault on Pazflor!|NOPT NOCO ATCO NOTE|Optical penetrator leak to be confirmed|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000055213|21/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|Oil in silicon.|ATCO NOPT NOCO NOTE|Oil found is from outercan installation|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|100001156|06/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|Guarantee claim 130 - SCSSV fu. transmit|NOTE NOPT NOCO|Unknown reason for failure|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P7000024191|01/06/2012|priority 1 |Q3|Unknown|Unknown|Interferência do trafo na calha|ATCO NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000068924|21/08/2011|priority 3 |Q3|TOTAL|Unknown|block not attached to baseplate|NOCO NOTE NOPT|Bolts not installed in SRM baseplate.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Change out of poor quality PTs|NOTE NOCO ATCO NOPT|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of DCVs and strainer|NOCO NOPT ATCO NOTE|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|100035400|20/01/2006|priority 3 |Q3|HESS|GOM|SIO CHANEL 5 IS DISPLAYING TIME OUT|ATCO NOTE NOPT NOCO|SIO CHANEL 5 IS DISPLAYING TIME OUT|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|7103233|28/06/2010|priority 1 |Q3|Unknown|Unknown|DWG-0208689-001 needs update|NOTE NOCO|Drawing incorrect  see QN200166338|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|P6000042968|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|19/01/2018|priority 1 |Q3|Unknown|Unknown|Ausência de leitura no sensor externo|ATCO NOCO NOPT NOTE|Unknown|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Assy |Operator Error
ZF|P7000001621|02/12/2011|priority 1 |Q3|Unknown|Unknown|Furação fora de centro na Outer Can|NOTE ATCO NOPT NOCO|decorrente do processo de reparo|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000088626|12/10/2015|priority 3 |Q3|Unknown|Unknown|missing inconel screws|NOCO NOTE NOPT|Inconel 718 screws missing in stock|Change/Deviation Request |Raw Material substitution request|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Missing Parts
ZF|100025661|08/08/2005|priority 2 |Q3|BP|GOM|INTERNAL PT OUT OF RANGE|NOPT NOCO NOTE ATCO|INTERNAL PT OUT OF RANGE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|SCM was full of calcium and rust|NOPT NOCO NOTE ATCO|Not sufficient cleaned and preserved|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Packaging & Storage
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
Q2|7102969|Unknown|priority 3 |Q2|Unknown|Unknown|Bytting solenoider på ventiler.|NOPT NOCO ATCO NOTE|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|P6000064911|02/11/2011|priority 3 |Q3|Unknown|Unknown|Config|NOPT NOCO ATCO NOTE|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOPT NOCO ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000024191|28/03/2013|priority 1 |Q3|Unknown|Unknown|PORCENTUAL DE ACEITAÇÃO FORA DO DESEJADO|ATCO NOTE NOPT NOCO|PROBLEMA NO EQUIPAMENTO DE TESTE|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000008275|20/06/2012|priority 1 |Q3|Unknown|Unknown|Arranhão na outercan|NOTE NOPT ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Damaged during assembly
ZF|P6000068902|09/01/2012|priority 3 |Q3|Unknown|Unknown|PT/TT wiring error|NOPT NOTE ATCO NOCO|PT\TT wiring error. Operator error.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000002082|19/02/2010|priority 1 |Q3|Unknown|Unknown|Vazamento de Silicone|ATCO NOTE NOCO NOPT|Silicon Leakage|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Damaged during assembly
ZF|100049000|10/12/2009|priority 3 |Q3|BP|Unknown|Damaged shear pin|NOCO NOTE NOPT ATCO|SCM installed on incorrect SCMMB bush|Damage |Damage Due to Handling|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P7000001843|25/03/2011|priority 1 |Q3|Unknown|Unknown|Oxidação Extension Rod Mexilhão RRP 05|ATCO NOTE NOPT NOCO|Unknown|Coating/Plating |Coating defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZB|100031223|22/04/2014|priority 1 |Q1|Unknown|Unknown|Warranty claim 261-GullfaksC-Com.probSCM|NOTE NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000042968|26/02/2010|priority 3 |Q3|TOTAL|WEST AFRICA|DHI error message received in ST report|NOCO NOPT NOTE ATCO|Unknown|Design |Specification Error|SS - Controls - Topside Products|N/A SW|FMC Engineering related |Engineering Error
ZF|100034440|04/11/2005|priority 4 |Q3|Unknown|Unknown|LOOSE SCREWS|NOPT NOCO NOTE ATCO|paint prevent sufficient holding tension|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|100020562|11/05/2010|priority 3 |Q1|BP|GOM|Over torqued to the skid|ATCO NOCO NOTE|Over torqued to the skid|Damage |Damage during assembly|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Assy |Operator Error
ZF|100046387|25/07/2018|priority 3 |Q3|Unknown|Unknown|CITV test during DEMOB|NOPT NOTE NOCO ATCO|Lack of available CPI test equipment|TEST |Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missing Parts
ZF|P7000039672|07/08/2014|priority 1 |Q3|Unknown|Unknown|Revestimento danificado|NOCO ATCO NOTE NOPT||||Damage |Damage Due to Handling|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Improper handling
ZE|P6000074156|03/02/2015|priority 3 |Q3|Unknown|Unknown|(CDM)SCM #410 Hydroulic PT sensor failed|ATCO NOPT NOTE NOCO|Hydroulic PT sensor failed|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Change Seq. of Procedure
ZE|100056918|02/05/2013|priority 2 |Q3|Unknown|Unknown|SCM Leak Test Fail|NOCO NOTE ATCO|Cannot Hold Pressure|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|7105128|18/02/2004|priority 3 |Q3|Unknown|Unknown|CV PMV leaked on 1st operation from LPA|NOPT NOTE NOCO|Unrepeatable leak in LP control valve.|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Other causes|Miscellaneous
Q3|100006609|12/02/2003|priority Unknown|Q3|PETROBRAS|Unknown|No communication with SEM A|NOPT NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7101172|17/10/2001|priority 2 |Q3|STATOIL|NORTH SEA|SCM Leak from SCSSV-solenoid to return|NOCO NOTI ATCO NOPT|SCSSV HPCV leaking|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZB|7102969|03/01/2007|priority 2 |Q1|MOBIL EG|Unknown|Unable to establish communications|NOCO NOTE ATCO|To be inspected upon retrieval.|Assembly/Test Related |Function|Subsea Control Module (SCM) El. act.syst|Control electronics|FMC Other causes |Do Not Use
ZF|P6000083428|24/07/2012|priority 3 |Q3|Unknown|Unknown|Change over valve failues to function|NOTE NOPT NOCO|operator error during test set-up|Test Related |OBS-Missed Operation|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Operator Error
ZE|P6000123495|06/04/2016|priority 3 |Q3|Unknown|Unknown|High internal leakage - control valves|ATCO NOPT NOCO NOTE|High internal leakage - control valves|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Causes for Improvement|Process/Procedure Not Being Followed
ZB|P6000042969|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 03|NOPT ATCO NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100025735|21/02/2014|priority 3 |Q3|OVERALL PROJECT ROLL-UP SKIRNE / BYGGVEWELL NO E-1H - BLOCK 25/5-3|Unknown|Brayco SCM flushed with Transaqua HT2|NOTE ATCO NOCO|Flushed Brayco SCM with waterbased fluid|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZB|P6000101955|04/07/2014|priority 3 |Q1|STATOIL|NORTH SEA|SCM 2&3 TYR Silicon filling / mob issues|NOCO NOTE NOPT ATCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|100037965|16/05/2014|priority 2 |Q3|Unknown|Unknown|SCM locking mechanism damage during ops|NOCO ATCO NOTE|torque in procedure potentially too high|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000079433|13/02/2012|priority 3 |Q3|Unknown|Unknown|CVLP4 and CVHP24 Not working as expected|NOPT NOTE NOCO|Opr.error when wiring SCM  Spec OK|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|7101401|24/10/2014|priority 3 |Q3|PETROBRAS|Unknown|MMR - CVLP19 External Leakage|ATCO NOCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Engineering related |Continuous Improvement
ZF|P6000050867|26/10/2010|priority 1 |Q3|Unknown|Unknown|FAT stopped due to software problems|NOPT NOCO NOTE|FMC Engineering related: Engineering Err|Test Related |OBS-Function|SS - Controls -Computer system software|Electrical solution SW|FMC Engineering related |Engineering Error
Q3|7105128|05/11/1999|priority 3 |Q3|Unknown|Unknown|SCM P 01|NOPT NOCO NOTI ATCO|Unknown|101-Mechanical|Outer Can|Def. loc. - Testing (not int. SCM)|SWT (Shallow Water Test)|Initial/Direct product problem|Marking
Q3|100017997|12/06/2002|priority 3 |Q3|Unknown|Unknown|SCM  various punches at final inspection|ATCO NOPT NOCO NOTI|New hydraulic couplers not yet qualified|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Product Not Qualified
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 24 ÅsgA I2-H PT XOV malfunction|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZE|100048038|03/04/2017|priority 2 |Q3|Unknown|Unknown|(Alert) - #138 TQ -O- SCM|ATCO NOPT NOTE NOCO|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Causes for Improvement|Documentation
ZB|P6000063531|25/07/2017|priority 2 |Q1|Unknown|Unknown|Vigdis ALD function failed mobilisation|NOCO NOTE ATCO|TFMC does not accept liability|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIII|Other external causes |Customer Error/responsibility
ZF|P7000039672|30/03/2016|priority 1 |Q3|Unknown|Unknown|Vazamento no Manifold Block|NOTE NOCO ATCO NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZB|100067526|28/10/2014|priority 1 |Q1|Unknown|Unknown|GC 266 SCM Comm. probl.|NOCO NOTE ATCO|component failure inside/external errors|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000016420|13/12/2010|priority 1 |Q3|Unknown|Unknown|Filtro do compensador|NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|FKS Quality system issues|Resource Management|FMC Other causes/damage |Planning error
Q1|7105129|31/01/2003|priority 3 |Q1|TOTAL|Unknown|SCM 07I GIR communication problems SEM A|ATCO NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - Luanda (Angola)|Work Shop|Initial/Direct product problem|Function
Q1|7102643|Unknown|priority 1 |Q1|Unknown|Unknown|SCM 14  el. conn. lock ring missing|NOTI NOPT NOCO ATCO|Missed on final inspection|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Bergen workshop|Root cause QA/QS|QA/QS Inspection error
ZF|100020562|03/08/2009|priority 2 |Q3|BP|GOM|Voltage reference error|NOCO NOPT NOTE ATCO|Defective DC/DC converter (Datel)|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000042968|03/03/2010|priority 2 |Q3|Unknown|Unknown|New config due to software upgrade.|ATCO NOPT NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - Topside Products|N/A SW|FMC Engineering related |Engineering Error
ZF|100066325|11/03/2016|priority 3 |Q3|Unknown|Unknown|El connector fault SSP OH003 (Statfjord)|ATCO NOCO NOTE|Unknown|Test Related |OBS-Function|SS - Compl. & W.Over - XT - General|Electrical Connectors|FMC Engineering related |Specification error
ZF|P7000000897|17/05/2013|priority 1 |Q3|Unknown|Unknown|Lock/UnLock out of the specification|NOTE NOCO NOPT ATCO|101545 - KRISTIANSANDS SKRUEFABRIKK &|Marking |Marking content error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000064909|05/10/2011|priority 3 |Q3|Unknown|Unknown|Wiring fault on EC5|NOTE NOPT NOCO|Human failure  wrong wiring (spec is OK)|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000029772|25/03/2009|priority 1 |Q3|ENGIE|NORTH SEA|Batch missing on outercan bolts|NOTE NOCO NOPT|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|P6000101955|12/02/2014|priority 3 |Q3|Unknown|Unknown|Wrong nameplates used on SCM`s|NOPT ATCO NOTE NOCO|Wrong nameplates in dwg|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZD|P6000105542|01/12/2014|priority 1 |Q2|Unknown|Unknown|RV leaking on top of SCM|ATCO NOTE NOCO|SCM LEAKING RTV|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|P7000008275|02/08/2010|priority 1 |Q3|Unknown|Unknown|Reprovação do manifold block|ATCO NOCO NOTE NOPT|Unknown|Damage |Damage during transport|SS - Compl. & W.Over - XT - General|Horizontal Penetrators|FMC Other causes/damage |Damage during transport
ZF|P6000028371|23/01/2008|priority 3 |Q3|SHELL|GOM|Replacement of COV and strainer|NOPT NOTE ATCO NOCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000100953|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100031193|25/08/2005|priority 3 |Q3|PETROBRAS|Unknown|SCM DPR 2500 SN#02|NOCO NOTE ATCO|Marginal design|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|P6000069056|14/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|Wiring ERROR PowerCan|NOPT NOTE NOCO|Opr.fmistake  mixing wiries between SEMs|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Harness|FMC Assy |Operator Error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #4 Wiring|ATCO NOCO NOTE NOPT|BPTH SKOFLO SCM SN #4 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100036936|05/11/2008|priority 2 |Q3|STATOIL|NORTH SEA|Leakage in HP lines|NOCO NOTE NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Test |Operator Error
ZB|100056261|21/12/2009|priority 2 |Q1|MURPHY|WEST AFRICA|SEM Common Alarm|NOTE NOCO ATCO|SEM Common Alarm|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |Damage from Wear and Tear
ZE|P6000064910|25/09/2018|priority 2 |Q3|Unknown|Unknown|SGP- MCM Sup Sensor Failure -TEP-SPS-047|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|P6000042969|24/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 12|NOPT NOTE NOCO ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
Q3|100016901|09/01/2003|priority 3 |Q3|BP|GOM|Silicone leakage|NOPT ATCO NOTI NOCO|Zip tie found between outer can & basepl|100-SCM/RCM|Subsea Control Module|Ext. loc. - KOS Houston|Goods Receipt|Root cause Assembly/Test|Workshop-Assembly/Test error
ZE|P6000120925|26/02/2016|priority 3 |Q3|Unknown|Unknown|SCM MK III -P6000120925|NOTE NOCO ATCO|Digital signatures added to MRB|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|100020278|01/12/2010|priority 2 |Q3|Unknown|Unknown|Pin not fit|NOCO NOPT NOTE|Change pin to smaller one which fits|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|100018531|30/09/2014|priority 2 |Q3|SHELL|Unknown|MMR - nonconforming nameplate|NOCO NOTE ATCO|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
Q3|7102643|15/11/1999|priority 3 |Q3|Unknown|Unknown|SCMs  return line bleed nipple loctited|NOCO NOTI ATCO NOPT|Unknown|101-Mechanical|Mechanical Components|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZF|100020562|18/02/2010|priority 1 |Q3|BP|GOM|BPTH SCM 26 Internal PT AI Offset|NOTE ATCO NOCO NOPT|BPTH SCM 26 Internal PT AI Offset|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZF|P6000058949|19/04/2011|priority 3 |Q3|Unknown|Unknown|Checkvalve on CHKV33-HP is not assembled|NOPT NOCO NOTE ATCO|Checkvalve on CHKV33-HP is not assembled|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Assy |Missing Parts
ZF|100005667|08/01/2015|priority Unknown|Q3|Unknown|Unknown|SCM not maintained acc to FMC standards|NOTE ATCO NOPT NOCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100052134|28/06/2006|priority 1 |Q3|PETROBRAS|GOM|Wrong colour according to spec. SCM 83|NOPT NOCO NOTE|Painted incorrect color|Coating |Painting Defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|P7000039672|05/09/2018|priority 1 |Q3|Unknown|Unknown|ECN  7090703    PN  P7000017838|ATCO NOPT NOCO NOTE|Error-concept/calculation|Design |DBI Error|Object Types to Eng Matl CLASS|kits|FMC Engineering related |ECN Change
ZF|3787102|15/03/2007|priority 2 |Q3|STATOIL|NORTH SEA|Snorre WCM documentation needs update|NOTE ATCO NOCO NOPT|Unknown|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Continuous Improvement
ZF|P7000016420|25/11/2010|priority 1 |Q3|Unknown|Unknown|Desvio no SRT|NOTE NOCO ATCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZF|P7000039672|01/04/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOCO NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100048038|08/06/2007|priority 1 |Q3|Unknown|Unknown|WRONG READINGS ON VERIFICATION TEST|ATCO NOCO NOPT NOTE|WRONG READINGS DURING TESTING|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
ZF|P6000065528|04/04/2011|priority 3 |Q3|Unknown|Unknown|blindelokket passer ikke til ytterkanna.|NOTE NOCO ATCO NOPT|Follow up in ZD QN: 200200917|Machining Related |OBS-Outside Diameter Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
Q3|7103233|10/04/2001|priority 3 |Q3|Unknown|Unknown|Crack press. on LP check valve too low|NOTI ATCO NOCO NOPT|Check valve cracking pressure too low|101-Mechanical|Mechanical Components|Ext. Loc. - St.Johns (Canada)|Goods Receipt|Initial/Direct product problem|Function
Q3|7101401|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upågrade Marlim SCM 04-ALFA to 04-GAMA|NOTI NOPT ATCO NOCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
ZF|100025661|05/06/2006|priority 3 |Q3|HOUSTON STOCKING SCM MK II (15K)|Unknown|RIT Downhole Gauge Test|NOPT NOTE NOCO ATCO|Test Document Error|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
Q3|100017305|08/11/2002|priority Unknown|Q3|STATOIL|Unknown|Water penetration in SCM at Stackup test|NOCO ATCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P6000110380|20/01/2014|priority 4 |Q3|Unknown|Unknown|Trafo assembly|NOPT NOTE NOCO ATCO|Error in DBI  julia SRM|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|7102969|09/05/2005|priority 3 |Q3|Unknown|Unknown|Broken bolt|ATCO NOPT NOTE NOCO|Component failure|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of COV and strainer|NOCO NOTE ATCO NOPT|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|7104075|17/05/2005|priority 2 |Q3|MARUBENI|GOM|SCM14 failed pt's|NOPT ATCO NOCO NOTE|RIT failure during refurb of SCM|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000122574|09/09/2015|priority 2 |Q3|Unknown|Unknown|lekkasje under trykktest|NOCO NOTE NOPT ATCO|Screws assembled in wrong position.|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Operator Error
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO ATCO|Unknown|Project|Project Requested Unfinished shipment|FKS Quality system issues|Quality Management System|FMC Materials/Stores related |Improper Handling
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|MIssing batch numbers SCM 02|NOPT NOCO NOTE|Unknown|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100054943|24/10/2007|priority 2 |Q3|WOODSIDE|Unknown|(SS) XT SENSOR TEST NOT PERFORMED|NOPT NOTE NOCO|operator error|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - Sensors|Pressure & Temperature Transmitter (PT/T|FMC Assy |Operator Error
ZF|P6000098616|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000107981|04/09/2014|priority 2 |Q3|Unknown|Unknown|SCM Nameplate Incorrect|NOCO NOTE ATCO NOPT|SCM Nameplate Incorrect|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZE|P6000068770|13/11/2012|priority 3 |Q3|Unknown|Unknown|WOCM & SCMs power consumption reading|NOCO ATCO NOTE NOPT|FMC opr. requested Improvement|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Handle Tooling Issue
ZF|7102969|26/04/2005|priority 3 |Q3|MOBIL EG|Unknown|solinoid valve function|ATCO NOTE NOPT NOCO|solinoid valve function|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000116166|14/04/2016|priority 3 |Q3|Unknown|Unknown|Blank labels were installed on Elec. Cap|DLFL NOCO|Customer requested change|FMC Other Defect |Physical|SS - Controls - Electric Products|Electrical Harness|FMC Other causes/damage |Planning error
ZF|100020562|22/03/2005|priority 1 |Q3|BP|GOM|SCM Software Needs to be updated|ATCO NOTE NOPT NOCO|Design specifications change|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100025661|20/04/2006|priority 2 |Q3|PETROBRAS|GOM|CITV not working properly|NOCO ATCO NOTE NOPT|wiring error|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q1|7103382|11/03/2002|priority 2 |Q1|MELLITAH OIL & GAS  BOURI|Unknown|SCM 02 Bouri B3-21  AI card malfunction|NOTI ATCO NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Bouri DP 3|Initial/Direct product problem|Function
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|COMPONENT NOT UP TO CURRENT VERSION|NOCO NOPT NOTE ATCO|COMPONENT NOT UP TO CURRENT VERSION|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
Q3|7103233|24/01/2000|priority 4 |Q3|Unknown|Unknown|SCM nitrogen filling equip/PRD required|ATCO NOCO NOPT NOTI|No KOS procedure for nitrogen filling|102-Hydraulic|Accumulators|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|100037428|03/11/2006|priority 1 |Q3|TOTAL|WEST AFRICA|SCM DH gauge error|NOCO ATCO NOPT NOTE|failure caused by short circuit|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
Q3|7104670|09/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|SIO-kort brent ?|NOTI ATCO NOCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100025661|12/05/2004|priority 3 |Q3|Unknown|Unknown| VACUUM TUBE ASSY|ATCO NOPT NOCO NOTE|Erroneous drawing.|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Engineering related|Design Specification/Drawing error
ZF|100068622|12/10/2016|priority 3 |Q3|Unknown|Unknown|Not able to perform WGM/MFM test in HFT|ATCO NOCO NOPT NOTE|No available CPI test equipment.|TEST |Missed Operation|SS - Controls -SCM el/opt components|Other el/opt components|FMC Test |Tooling
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|RS 485 SIMULATOR FUNCTION REQUIREMENT|NOTE ATCO NOCO NOPT|HFT DOC. & TEST UNIT DISCREPANCY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZB|100048038|26/05/2010|priority 2 |Q1|CHEVRON|WEST AFRICA|PT for PMV failure on AGB 3|NOCO ATCO NOTE|PT for PMV failure on AGB 3|Damage |Wear & Tear|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000039672|27/02/2018|priority 1 |Q3|Unknown|Unknown|Diâmetro da Rosca não conforme|ATCO NOTE NOPT NOCO|Unknown|Assembly |Dimension (tolerance)|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Specification not followed
ZF|P6000102687|18/08/2014|priority 4 |Q3|Unknown|Unknown|Update KS200e SW for Egina|NOCO ATCO NOTE|Com. functionality which was not cons.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000088614|27/07/2015|priority 2 |Q3|Unknown|Unknown|Threads too tight|NOTE NOPT NOCO|Bad edge in beginning of thread|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Tooling
ZF|P6000055605|15/09/2011|priority 3 |Q3|Unknown|Unknown|Wrong wiring PT\TT 3|NOPT NOTE NOCO|Wiring error. Cause not found|Marking |Marking content error|SS - Controls -SCM el/opt components|SCM Wiring|FMC Other causes/damage |Cause not found
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #19 Wiring|ATCO NOTE NOPT NOCO|BPTH SKOFLO SCM SN #19 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZB|P6000043122|02/09/2010|priority 2 |Q1|TOTAL|Unknown|Punch List SCM SSS 04|ATCO NOPT NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000039672|07/03/2014|priority 1 |Q3|Unknown|Unknown|Perda da folha do Traceability|NOCO ATCO NOTE NOPT|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|P7000024900|14/10/2013|priority 1 |Q3|Unknown|Unknown|SOLICITAÇÃO DE CONCESSÃO|NOTE NOCO ATCO NOPT|concessão|FMC Other Defect |Physical|SS - Controls -SCM Test Stand|Other mechanical components|FMC Other causes/damage |Planning error
ZF|P6000062990|24/06/2015|priority 2 |Q3|Unknown|Unknown|Unclear requirements in ECN|NOCO NOTE ATCO|Wrong ECN class selected at rev release|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOCO NOPT ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZE|P6000104111|05/11/2018|priority 4 |Q3|TOTAL|WEST AFRICA|MIV 1 Transmitter P10 Failure (SCM 19)|OSTS NOTE NOPT NOPR|No failuare found|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Test |Other- Specify in comments
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider .|ATCO NOPT NOCO NOTI|Unknown|Defect types / mechanical parts productn|Damages|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Design
ZF|P7000000897|15/06/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|NOTE ATCO NOCO NOPT|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000024191|02/07/2012|priority 1 |Q3|Unknown|Unknown|SRT não aceito pela inspeção cliente|NOCO ATCO NOTE NOPT|Documento não marcado como HP|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|100052701|25/01/2008|priority 2 |Q3|Unknown|Unknown|Top of SCM is not marked  Tøn18|NOCO NOPT NOTE|Unknown|Marking |No Marking|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Do Not Use
ZF|3794920|19/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|Unknown|NOTE ATCO NOPT NOCO|proper claning during mobilisation|FMC Other Defect |Physical|FKS Quality system issues|Product Realization|FMC Machine Shop Personnel |Operator error
ZB|P1000004979|29/10/2008|priority 3 |Q1|BP|GOM|SCM Extension rod Shear pin Failure|NOCO NOTE|SCM Extension rod Shear pin Failure|Damage |Damage during transport|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Other causes/damage |Damage during transport
ZF|P7000001621|26/01/2012|priority 1 |Q3|Unknown|Unknown|Furação desalinhada da Hose house|NOPT ATCO NOCO NOTE|Equipamento retornou do campo|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000001621|29/07/2010|priority 1 |Q3|Unknown|Unknown|Hose House Hercules SN 03|NOTE NOPT NOCO ATCO|Furação nao casa|Assembly Related |OBS-Interface issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Machine Shop Personnel |Operator error
ZF|100025661|22/03/2006|priority 2 |Q3|SHELL|GOM|Water in silicon sample after tank test|ATCO NOPT NOCO NOTE|leak in test equipment - worn seal ring|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|P6000076121|19/08/2011|priority 3 |Q3|Unknown|Unknown|CITV  no connection with module/ST|NOPT ATCO NOCO NOTE| Equipment Malfunction|Test Related |OBS-Component Error|SS - Controls - Test and Transportation|Sensor Simulator (SESI)|Vendor related |Equipment Malfunction
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|13/05/2014|priority 1 |Q3|Unknown|Unknown|PT reading a wrong pressure|ATCO NOCO NOPT NOTE|3732 Kulite Semiconductor Products  Inc.|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Other causes/damage |Cause not found
ZB|P6000037215|09/11/2010|priority 2 |Q1|Unknown|Unknown|Warranty Claim # 016- Electrical actuat|NOTE NOPT NOCO ATCO|Software error|FMC Other Defect |Functional|Customer Compliant|Noncompliance to Customer Requirement|FMC Engineering related |Engineering Error
ZF|P7000039672|09/01/2017|priority 1 |Q3|Unknown|Unknown|Falha na Comunicação SEM A|NOTE NOPT NOCO ATCO|Unknown|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIIE|Intercompany|FMC Kongsberg
ZF|100035118|30/09/2005|priority 3 |Q3|WOODSIDE|Unknown|Problems with closing commands of SCM|NOCO ATCO NOPT NOTE|SW timing conflict when 2 SCMs on 1 line|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100052701|14/08/2007|priority 3 |Q3|STATOIL|NORTH SEA|Airpocket in epoxy on PT|ATCO NOTE NOPT NOCO|No non compliance|Assembly/Test Related |Dimension (tolerance)|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|FMC Other causes |No Non-Compliance
ZE|P6000147859|24/04/2018|priority 2 |Q3|Unknown|Unknown|SCM  Marking Issue|NOPR OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100046387|06/11/2015|priority 3 |Q3|Unknown|Unknown|CITV and MPFM test in FAT|NOTE NOCO|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100031193|11/06/2012|priority 1 |Q3|PETROBRAS|Unknown|COV LP com vazamento para retorno|NOPT ATCO NOTE NOCO|Equipamento Reparo|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Other external causes |Customer Error/responsibility
ZF|7104670|26/02/2015|priority 2 |Q3|Unknown|Unknown|Company requested NOT perform upgrade|NOCO NOPT NOTE ATCO|Unknown|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100050519|27/03/2006|priority 1 |Q3|TOTAL|Unknown|No proper comm.  with the DHI card|NOCO NOPT NOTE ATCO|Wiringerror caused cross-talk in comm.|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000102554|19/12/2013|priority 3 |Q3|Unknown|Unknown|Smarttool configuration changes|ATCO NOTE NOPT NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Specification error
ZE|100067526|01/09/2016|priority 3 |Q3|Unknown|Unknown|PN 100067526 Drawings and BOM issues|NOTE ATCO NOCO|PN 100067526 Drawings and BOM issues|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000100953|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100037427|04/07/2011|priority 3 |Q3|TOTAL|WEST AFRICA|incorrect rev of procedure is used|NOTE NOCO|Ref QN: 200213490.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100001156|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|Silicon Leakage on SCM GFS PH2 SN 18|NOPT NOTE ATCO NOCO|Root cause unknown.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Engineering related |DWG Error
ZF|100017997|18/06/2010|priority 1 |Q3|BP|Unknown|BPTH IWOCS 4 SCM EC conn. seal surfaces|NOPT ATCO NOTE NOCO|Probable causes exist  nothing definate.|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Damage Due to Corrosion
ZF|P6000068924|25/10/2011|priority 1 |Q3|TOTAL|Unknown|Wrong use of miniseal|NOTE ATCO NOCO|Procedures need update with miniseal use|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Electrical Wire|FMC Engineering related |Procedure error
ZF|100037967|27/06/2012|priority 2 |Q3|Unknown|Unknown|SCM 9  HFT  PRD voltage clarification|NOPT NOTE NOCO|Typo in procedure.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000067533|15/08/2011|priority 2 |Q3|KIRINSKOYE SPS|Unknown|wrong language on GA dwg in sap.|NOTE NOCO NOPT|ENG GA DWG is linked in DBI/SAP and TCE|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|7104670|14/01/2004|priority 3 |Q3|STATOIL|NORTH SEA|SIO-cards burnt|NOTE NOPT ATCO NOCO|Specification completed.|Service/maintenance related|Unknown|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Other causes|Miscellaneous
ZF|100017997|17/10/2003|priority 2 |Q3|BP|GOM|Inaccurate readings on SCM PT`s at ETU|ATCO NOTE NOPT NOCO|Un realistic test|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|Power supply|FMC Engineering related|Design Specification/Drawing error
Q1|7105129|31/01/2003|priority 3 |Q1|TOTAL|Unknown|SCM 08I Communication checksum error|NOPT ATCO NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Pride Angola|Initial/Direct product problem|Function
ZF|P7000008275|04/01/2013|priority 1 |Q3|Unknown|Unknown|Stabs da Outercan empenados|NOCO NOPT NOTE ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Test |Damaged during testing
ZF|P7000039672|20/05/2015|priority 1 |Q3|Unknown|Unknown|Leakage out of acceptance criteria PS#62|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000069056|28/09/2011|priority 3 |Q3|STATOIL|NORTH SEA|Cable marking on EC 7 11 & 12 switched|NOCO NOPT NOTE| Wrong SCM wiring due to wrong marking|Marking |Marking content error|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Assy |Operator Error
ZF|P6000093498|04/08/2014|priority 4 |Q3|Unknown|Unknown|Guide pin is not fitting|NOPT ATCO NOTE NOCO|No freehole for one of the guide pins|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000039844|01/10/2010|priority 2 |Q3|SHELL|Unknown|Wrong dates on Prosedure for SW|NOTE NOPT ATCO NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|Basis 200 SW|FMC Engineering related |Engineering Error
ZF|100056918|23/06/2010|priority 3 |Q3|Unknown|Unknown|Unknown|NOPT NOTE NOCO ATCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|150/615 SW|FMC Engineering related |Engineering Error
ZB|P6000088751|23/09/2016|priority 2 |Q1|Unknown|Unknown|WEL  SCM  L2 escape|NOTE NOCO ATCO NOPT|Unknown|Documentation Requirement |Procedure / Process Error|Object Types to Eng Matl CLASS|scm_mkIIE|Projects Related|Documentation error
Q3|100013155|20/11/2000|priority 4 |Q3|OVERALL PROJECT ROLL-UP|Unknown|SCM test results  customer comments|ATCO NOTI NOPT NOCO|Minor errors in testing documentation|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZB|100052701|01/12/2010|priority 3 |Q1|Unknown|Unknown|Tyrihans Claim 024 COV|ATCO NOTE NOCO NOPT|COV has too low rating|FMC Other Defect |Physical|Customer Compliant|Noncompliance to Customer Requirement|FMC Engineering related |Specification error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOTE NOCO ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100056261|11/03/2010|priority 3 |Q3|Unknown|Unknown|HFT60033185 Errors|ATCO NOTE NOCO|Engineering error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
Q1|3801623|04/11/1999|priority Unknown|Q1|Unknown|Unknown|AWV Control Valve Hyd leak  well C-4H|NOPT NOTI NOCO ATCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Unknown|Unknown|Initial/Direct product problem|Leakage
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|INTERNAL PT FAIL IR TEST|NOCO NOPT NOTE ATCO|INTERNAL PT FAIL IR TEST|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
Q3|7104033|Unknown|priority 3 |Q3|Unknown|Unknown|Manglet O-ring på adpterplate.|NOPT ATCO NOTI NOCO|Unknown|101-Mechanical|Mechanical Components|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Material
ZF|100052134|23/05/2006|priority 3 |Q3|Unknown|Unknown|actual reading not what procedure wants|NOPT NOTE ATCO NOCO|Accept Assembly For Use|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q1|7101172|08/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|Refurbishment of SCM|NOPT ATCO NOTI NOCO|Refurbishment|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|P7000039672|16/02/2017|priority 1 |Q3|Unknown|Unknown|SCM - Vazamento Adapter Plate LP|NOTE NOCO ATCO NOPT|Unknown|TEST |Leak|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Incorrect set up/testing
ZE|P6000028371|08/06/2010|priority 2 |Q3|Unknown|Unknown|Z Impact for software|NOTE ATCO NOCO NOPT|Unknown|Unknown|Unknown|Subsea Control Module (SCM) Electrical|Processor PCBs|Causes for Improvement|Lack of training
ZF|100056261|27/04/2011|priority 3 |Q3|Unknown|Unknown|Revise Test Procedure|ATCO NOCO NOPT NOTE|HFT  Procedure HFT 60033185/D|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZD|7102969|20/09/2013|priority 3 |Q2|Unknown|Unknown|Incorrect coating|NOCO ATCO NOTE|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Coating Defect
ZF|100049000|15/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOTE ATCO NOCO NOPT|Dial caliper coupler measurements|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZD|100049000|11/02/2006|priority 3 |Q2|Unknown|Unknown|MARKING|NOPT NOCO ATCO NOTE|Revision Letter Not On Part|Marking |No Marking|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
Q3|7104075|26/04/2000|priority Unknown|Q3|Unknown|Unknown|Failure in supply voltage|NOTI NOCO NOPT ATCO|Unknown|103-Electrical|SEM El.Rack|Ext. loc. - KOS Houston|Work Shop|Initial/Direct product problem|Function
ZB|100068622|11/06/2014|priority 1 |Q1|Unknown|Unknown|Warranty claim 264-Unable to turn power|ATCO NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000109984|24/04/2014|priority 4 |Q3|Unknown|Unknown|Interface issue for top plate|NOTE ATCO NOCO|Wrong top plate specified in BOM|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
Q1|7101172|Unknown|priority 2 |Q1|Unknown|Unknown|Pressure drop when PMV or PWV operated|NOCO NOPT ATCO NOTI|Design - restrictors to be introduced|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - offshore/field|Gullfaks A|Root cause Engineering|Design Specification error
ZF|100052134|14/07/2006|priority 3 |Q3|PETROBRAS|GOM|WRONG SEM B DHI ADDRESS INDICATED ON SCM|NOPT ATCO NOCO NOTE|Wrong SEM B Address|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Test error
ZF|7100320|22/04/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Broken fitting Outer Can|NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 01|NOCO NOTE NOPT ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100056176|15/12/2009|priority 1 |Q1|STATOIL|NORTH SEA|Warranty Claim 182 Loss of comm DHI 119|NOPT NOTE NOCO ATCO|Customer Provided Item|FMC Other Defect |Functional|Customer Compliant|Noncompliance to Customer Requirement|Projects Related|Free Issue Delivery
ZF|P7000008275|27/08/2010|priority 2 |Q3|Unknown|Unknown|Problem With APSD1 - P6000020498|ATCO NOTE NOPT NOCO|Unknown|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes/damage |Cause not found
ZF|P7000039672|28/08/2013|priority 1 |Q3|Unknown|Unknown|Parafuso cisalhado|NOTE ATCO NOPT NOCO|124086 PARNOX IND E COM DE ARTIGOS IND L|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Final Inspection Error
ZF|P7000024900|10/07/2012|priority 1 |Q3|Unknown|Unknown|Transformer no conformably|NOCO ATCO NOPT NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|P6000116166|03/05/2016|priority 3 |Q3|Unknown|Unknown|Drops of water in the silicon sample|NOTE NOPT ATCO NOCO|SCM not cleaned before silicone filling|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100030542|19/09/2005|priority 3 |Q3|Unknown|Unknown|SCM Procedures Have Not Been Followed|NOCO ATCO NOTE NOPT|Procedures not followed|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Refurbishment  Bytting av solenoider|ATCO NOCO NOTE NOPT|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
Q3|7102643|05/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM  int/ext sensors failed SEM A  N-4H|NOPT NOTI NOCO ATCO|Not yet known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q3|100005667|02/02/2000|priority Unknown|Q3|Unknown|Unknown|Åsg SCM 32  12 pin con. marking missing|NOPT NOTI NOCO ATCO|KOS dwg does not give enough infomation|101-Mechanical|Outer Can|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZE|P6000122626|09/07/2018|priority 3 |Q3|Unknown|Unknown|SCM  Updates to Agbami 615 Test procedur|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100016711|06/01/2010|priority 2 |Q1|BP|GOM|Lock Dog Separated From Locking Mech|NOTE NOPT NOCO ATCO|Lock Dog Separated From Locking Mech|Raw Material |OBS-Defects in material|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000105542|06/12/2013|priority 3 |Q3|Unknown|Unknown|Voltage dropped in SEM ESS vibration tst|NOTE NOPT NOCO ATCO|Bad connection at CFG Faston contact J63|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Test |Damaged during testing
ZF|P6000105542|27/10/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|ATCO NOCO NOPT NOTE|Unknown|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIII|FMC Test |Missed operation
ZF|3787102|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|100055762|19/05/2008|priority 1 |Q3|Unknown|Unknown|SCM material/documentation discrepancies|NOCO ATCO NOPT NOTE|Unknown|Marking |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000088604|26/11/2012|priority 1 |Q3|Unknown|Unknown|Bench vise marks on LP & HP Check valves|ATCO NOCO NOTE NOPT|Wrong use of bench wise|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Test |Operator Error
ZF|100055762|23/04/2008|priority 3 |Q3|STATOIL|NORTH SEA|Batch numbers missing|NOTE NOCO NOPT|QC change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
Q3|7104670|15/09/2000|priority 3 |Q3|Unknown|Unknown|XT / SCM / TH lines blocked without expl|ATCO NOPT NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
ZF|100017278|13/04/2015|priority 2 |Q3|Unknown|Unknown|Urgent repair of SCM|ATCO NOPT NOCO NOTE|Customer approved deviation|Coating/Plating |Coating defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|7101463|21/03/2012|priority 3 |Q3|Unknown|Unknown|procedure not correct per testing|NOCO NOTE|procedure not correct per testing|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
Q3|7101172|19/06/2001|priority 4 |Q3|STATOIL|NORTH SEA|HT PT under reads 79 bar on A & B|ATCO NOTI NOPT NOCO|Not known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|100048038|25/08/2014|priority 3 |Q3|Unknown|Unknown|Agbami tubing issues|NOCO NOTE ATCO|See DRM60116544|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZB|P6000043122|06/01/2010|priority 3 |Q1|TOTAL|WEST AFRICA|Punch List SCM SSS 03|NOCO NOTE NOPT|Missed operation/procedure not approved|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZB|100017997|01/03/2010|priority 2 |Q1|BP|GOM|Roughness out of tol. on EC face seal|NOTE NOPT NOCO ATCO|Roughness out of tol. on EC face seal|Raw Material |OBS-Hardness out of tolerance|Subsea Control Module (SCM) Mech w/MB|Outer can|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000121393|18/06/2015|priority 3 |Q3|Unknown|Unknown|Over torqued Check Valve|NOTE NOPT NOCO ATCO|Damaged at supplier  sent to FMC|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Specification not followed
ZB|100020278|26/11/2008|priority 2 |Q1|EXXONMOBIL|Unknown|08-MEGI-012: AIB Voltage Reference Error|NOCO NOTE|SEM B-Voltage Ref Error|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000122574|04/12/2018|priority 3 |Q3|Unknown|Unknown|SCM received with accumulator @ 120bar|NOTE ATCO NOCO|Accumulators not bleed off|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Operator Error
ZB|100001156|06/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|Guarantee claim 131 - Failure on sensors|NOPT NOCO NOTE|Unknown reason for failure|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZB|P6000105542|22/01/2016|priority 3 |Q1|Unknown|Unknown|Gullfaks GSO claim 294 SCM RandPT SUBSEA|NOCO ATCO NOTE|Equipment installed  need investigation|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT ATCO NOCO NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000042969|13/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|red hydraulic dust caps left on XT|NOCO ATCO NOTE NOPT|Red protector Caps lef on SCMMB|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZE|P6000055605|08/09/2015|priority 3 |Q3|Unknown|Unknown|improve records in MRBs for Shell|NOPT NOCO ATCO NOTE|records not placed in prod reports|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000088614|11/11/2014|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM MAN/SIV 03|NOTE ATCO NOCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100035118|23/09/2016|priority 2 |Q3|WOODSIDE|Unknown|High return pressure on HP|ATCO NOCO NOTE|Return line not connected.|TEST |Damaged During Testing|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Incorrect set up/testing
ZF|P7000008275|01/10/2010|priority 2 |Q3|Unknown|Unknown|Lack of o'ring groove on segments|ATCO NOPT NOTE NOCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte solonoider på ventiler.|ATCO NOTI NOPT NOCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
Q3|100018082|08/07/2002|priority Unknown|Q3|STATOIL|NORTH SEA|HYDRAULIC RETUR PT27 SHOWS 50BAR BY 0BAR|ATCO NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-EFAT|Root cause Vendor|Material/Component error
Q3|7104075|05/11/1999|priority 2 |Q3|Unknown|Unknown|SHE SCM 01  change PTs  mod. of DHI-108|ATCO NOPT NOTI NOCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Repair
ZF|100049000|31/08/2010|priority 3 |Q3|Unknown|Unknown|Unknown|NOTE NOCO NOPT|QN made 2 times see QN 200176570|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |QN Cancelled
ZF|100048038|12/04/2007|priority 2 |Q3|AGBAMI|Unknown|LP pressure changes AGB SN 24|ATCO NOCO NOTE NOPT|New requirements from customer|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZB|P6000039844|20/09/2018|priority 2 |Q1|Unknown|Unknown|Shell GK_ SCM#24_ Routine maintenance|NOTI OSTS OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000101955|06/05/2013|priority 2 |Q3|Unknown|Unknown|SCM nameplate SN digits not match body|NOTE ATCO NOCO|Wrong S/N marking on outecan  corrected|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Capture Mistake
ZF|100034629|09/02/2005|priority 3 |Q3|STATOIL|Unknown|High pressure against SCM P/N 100034629|NOCO ATCO NOPT NOTE|SCM LP supply overpressurised.|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|P6000077632|11/12/2015|priority 2 |Q1|Unknown|Unknown|Block 18 BP SCM #401 SEMA no comm|NOTE NOCO ATCO NOPT|SEM not communicating|Electrical |Other- Specify in comments|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Electrical |Other- Specify in comments
ZF|100017997|29/08/2012|priority 3 |Q3|Unknown|Unknown|Wiring fault CVLP 18|NOPT NOCO NOTE|Wiring inside SCM wrong.Wiring switched.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000024191|04/04/2013|priority 1 |Q3|Unknown|Unknown|Parafuso não monta na Outer Can..|NOPT ATCO NOTE NOCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Materials/Stores related |Damaged During Transport
ZB|100036936|20/10/2014|priority 3 |Q1|Unknown|Unknown|Lack of communication between Norne-DSB|ATCO NOTE NOPT NOCO|Human error|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Power units|FMC Test |Operator Error
ZF|P6000103208|05/02/2014|priority 3 |Q3|Unknown|Unknown|HP supply flowmeter is counting wrong|NOPT NOCO NOTE|Flowmeter not counting at minimum flow|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|100049000|11/04/2006|priority 3 |Q3|BP|Unknown|HFT DISCREPENCY|NOPT NOTE NOCO ATCO|HFT Instructions Issues|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000016420|13/12/2010|priority 2 |Q3|Unknown|Unknown|Conector e back shell danificado.|NOPT NOTE NOCO|Danificado na montagem|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Other Hydraulic Products|FMC Assy |Operator Error
ZB|100056261|29/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|SEM Common Alarm|NOTE ATCO NOCO|SEM Common Alarm|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Test |Damaged during testing
ZF|P6000031350|18/11/2008|priority 3 |Q3|Unknown|Unknown|MPR60036199 does not exist|NOTE ATCO NOCO|linked to DBI but not released-use EPLAN|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZB|100025661|31/07/2008|priority 3 |Q1|SHELL|GOM|LLANO2 SCM 49 Line B AI card faulted|NOPT NOTE NOCO ATCO|LLANO2 SCM 49 Line B AI card faulted|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|I/O PCBs|Vendor related |Equipment Malfunction
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOTE ATCO NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZD|P6000074156|13/03/2012|priority 3 |Q2|Unknown|Unknown|ATS-Missing Documentation|NOTE ATCO NOPT NOCO|DRL-0000020085  DRL-0000020034|Documentation |Missing Certificates / Records|Vendor Quality system issue|Quality Management System|Vendor related |Specification not followed
ZF|P7000016420|17/01/2012|priority 1 |Q3|Unknown|Unknown|Montagem da eletrônica na bracket|NOCO ATCO NOTE NOPT|MERCOTUBOS|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Specification not followed
ZF|100056261|08/01/2008|priority 3 |Q3|MURPHY|WEST AFRICA|batch missing|NOTE NOPT NOCO|Unknown|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
ZF|3801623|18/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOPT NOCO NOTE|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZB|P6000074156|17/07/2017|priority 3 |Q1|SHELL|Unknown|Shell  SCM 419  NCR #17|NOTE ATCO NOCO|Unknown|Design |Specification Error|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Tooling Malfunction
Q3|7105128|Unknown|priority 3 |Q3|Unknown|Unknown|SCM General|NOCO NOPT NOTI|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|100048038|26/03/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|Trafo problems on Agbami S/N 21|ATCO NOTE NOCO NOPT|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100025661|02/09/2005|priority 3 |Q3|SHELL|GOM|NO TEST SPECIFICATION LISTED ON DBI|NOPT NOTE NOCO ATCO|NO TEST SPECIFICATION LISTED ON DBI|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000100953|28/11/2013|priority 3 |Q3|Unknown|Unknown|Threads in outercan to short|NOPT NOCO NOTE|Interface with EC adapter not verified|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
Q3|7104033|17/01/2000|priority 3 |Q3|Unknown|Unknown|El rack koblingsfeil på module.|NOTI ATCO NOPT NOCO|Unknown|103-Electrical|SEM El.Rack|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|P6000042308|03/07/2009|priority 4 |Q3|TULLOW|WEST AFRICA|Alternate hydraulic fluid SCM test|NOTE NOCO ATCO|Alternate Hydraulic Fluid SCM Test|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|P6000093498|09/06/2014|priority 4 |Q3|Unknown|Unknown|Wiring fault|NOCO NOTE NOPT|Wiring error found in screening  no RCA|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000064910|20/07/2011|priority 3 |Q3|Unknown|Unknown|Power wiring to SEM A and B was crossed|NOTE NOPT NOCO|Wiring error by operator|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|3812476|18/12/2008|priority 2 |Q3|STATOIL|NORTH SEA|HFT on SCM has not been done|ATCO NOPT NOTE NOCO|HFT not performed|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|P6000102554|30/06/2014|priority 2 |Q3|Unknown|Unknown|Top plate discolored.|NOTE NOPT NOCO|Discoloration after hyperbaric  accepted|Coating/Plating |Painting Defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Coating Defect
ZF|P6000063531|27/12/2010|priority 1 |Q3|STATOIL|NORTH SEA|CPU600 improving startup on long umbilic|NOCO ATCO NOTE|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
Q1|7100320|27/02/2002|priority 3 |Q1|PETROBRAS|Unknown|LP filters coated  white/blue substance|NOCO NOPT NOTI|Hyd fluid contaminated?|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Cleanliness
ZF|100048038|14/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|Batch missing|NOTE NOPT NOCO|New requirements|Marking |No Marking|Common/Misc - Fasteners - Imperial|Screw|FMC Engineering related |Engineering Error
ZF|P7000008275|25/08/2010|priority 2 |Q3|Unknown|Unknown|Cisalhamento do Filter for Compensator|NOPT NOTE NOCO|Overtorque|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
Q3|100016110|04/04/2001|priority Unknown|Q3|Unknown|Unknown|Ceramic control valve in wrong position|NOTI NOPT ATCO NOCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Ext. loc. - KOS Houston|Work Shop|Root cause Assembly/Test|Workshop-Assembly/Test error
Q3|100001156|24/02/2000|priority 4 |Q3|Unknown|Unknown|All SCMs to have hyd. flow restrictors|NOCO ATCO NOTI NOPT|Instructions from system engineering|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZB|100020562|20/01/2010|priority 3 |Q1|BP|GOM|Leaking LP Changeover valve|NOCO NOTE NOPT ATCO|Leaking LP Changeover valve|Test Related |OBS-Leakage (Fluid)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|ATCO NOPT NOCO NOTE|Coupler Interface on m.block (spc error)|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Specification error
ZF|P6000064909|30/06/2011|priority 3 |Q3|Unknown|Unknown|CAT5 Ethernet coupler damaged|NOPT NOTE ATCO NOCO|CAT5 ethernet coupler damaged|Damage |Damage during assembly|SS - Controls -SCM Test Stand|Other el/opt components|Vendor related |Specification not followed
Q3|7103233|26/11/2001|priority 3 |Q3|Unknown|Unknown|SCM modified due to fault in Tub. Hanger|NOPT NOTI NOCO ATCO|Tub. Hanger DHPTT pins cross connected|202-Electrical/Sensor equipment|Electrical Pin Connetors|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
ZF|P7000024900|14/12/2012|priority 1 |Q3|Unknown|Unknown|EC without O`rings and guide pin|NOCO ATCO NOTE NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|El. Connector|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P6000037215|26/10/2010|priority 3 |Q3|ENGIE|NORTH SEA|Gjøa - El. Act. charging problem|NOCO ATCO NOTE|Software bug|FMC Other Defect |Functional|SS - Controls - Electric Products|Other Electric Products|FMC Engineering related |Engineering Error
ZF|P7000039672|16/05/2014|priority 4 |Q3|Unknown|Unknown|Cabeça do parafuso roletada durante mont|NOPT NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Physical Damage|Common/Misc - Fasteners - Metric|Bolt|FMC Assy |Manufacturing Engineer Erorr
ZF|P7000039672|06/04/2016|priority 1 |Q3|Unknown|Unknown|O'ring desconforme|DLFL NOCO|Desvio não pertinente|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZF|P7000000897|17/06/2011|priority 1 |Q3|Unknown|Unknown|Revestimento|NOCO NOPT NOTE ATCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Locking Mechanism|QA/QS/QI Related|Goods Receiving Inspection error
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|SO due to DC/DC Issue on AI150 card|ATCO NOCO NOPT NOTE|Component Failure/Poor Workmanship|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZD|100020562|01/09/2010|priority 3 |Q2|Unknown|Unknown|Sealing Surface error|ATCO NOPT NOCO NOTE|Sealing Surface error|Design |Material Master Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
Q3|100018600|06/02/2003|priority 3 |Q3|Unknown|Unknown|Rewiring of EC15 on all SCM's|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Root cause Engineering|Other Product Design error
ZF|100035013|19/01/2009|priority 2 |Q3|SHELL|Unknown|Cannot operate MDV on XT|ORAS NOTE ATCO NOCO|Lack of training - failed to refit plate|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P6000079032|22/11/2011|priority 3 |Q3|Unknown|Unknown|Fixes|NOPT ATCO NOTE NOCO|Std wire length too short-Need extension|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Harness|FMC Engineering related |Engineering Error
ZF|100068622|09/04/2015|priority 3 |Q3|Unknown|Unknown|Coating on outer can|ATCO NOTE NOPT NOCO|wear and tear|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Damage from Wear and Tear
Q3|3812476|05/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM10 NORNE upgr.DHI107/LP-Accu/PMV-sol.|ATCO NOPT NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Root cause Engineering|Material fault
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|MIssing batch numbers SCM 01|NOCO NOPT NOTE|Unknown|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZD|100049000|13/12/2006|priority 1 |Q2|BP|Unknown|INTERNAL PT FAILED ON SCM|NOCO NOPT ATCO NOTE|P/T FAILURE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100018531|09/08/2011|priority 1 |Q3|Unknown|Unknown|leakage teste failure|NOCO ATCO NOTE NOPT| Equipment in use for four years|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000080343|12/01/2012|priority 3 |Q3|Unknown|Unknown|Leakage from CVLP24 and CVHP55|NOPT NOCO ATCO NOTE|too much loctite on bolts caused leakage|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Operator Error
ZF|100030542|16/01/2008|priority 3 |Q3|BAOBAB ADD. XT P11/P12|Unknown|Batch numbers missing in iBASE list|NOPT NOTE NOCO|Change: batch cert. to batch management|Documentation |Incorrect Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|Bytting solenoider på ventiler.|ATCO NOPT NOCO NOTI|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Material
ZF|100017278|26/02/2013|priority 2 |Q3|Unknown|Unknown|Wrong item ref. in DWG-020442-004|ATCO NOCO NOTE|No DWG error found.|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Compensator|FMC Other causes/damage |QN Cancelled
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|Bytte av solonoider på ventiler.|NOCO ATCO NOPT NOTE|Unknown|Defect types / mechanical parts productn|Function|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production control
Q3|3787102|05/04/2002|priority 3 |Q3|STATOIL|NORTH SEA|Silicone in Return line on SCM.|NOPT ATCO NOTI NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore (HES)|Kongsberg SCM-126A/B|Initial/Direct product problem|Leakage
ZF|P6000069056|07/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|Drain holes for outercan not acc to dwg|NOCO NOTE|Outercan not produced acc to DWG|Machining Related |OBS-Slot Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P7000000229|24/06/2010|priority 1 |Q3|Unknown|Unknown|Revestimento|ATCO NOCO NOPT NOTE|Espessura acima do especificado|Coating/Plating |Painting Defect|SS - Compl. & W.Over - XT - General|Electrical Connection Systems|Paintshop Related|Operator error
ZE|P6000039844|28/06/2011|priority 2 |Q3|SHELL|Unknown|(SS) Improvement to SCM RIT Procedure|NOTE ATCO NOPT NOCO|No section to record the software versio|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM GFA 09 Wellhead temp. SEM B malfunct|ATCO NOCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|100035118|10/04/2015|priority 2 |Q3|Unknown|Unknown|Incorrect Transport and Handling of SCMs|OSTS OSNO|Shipment packed and coordinated by Compa|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000063633|07/07/2011|priority 3 |Q3|ENI|Unknown|incorrect rev of procedure is used|ATCO NOCO NOTE|Incorrect rev of filling procedure used.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|Conflict between strainer and SCMMB|NOPT NOTE ATCO NOCO|Conflict between strainer and SCMMB|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|100036232|24/04/2018|priority 3 |Q3|Unknown|Unknown|Missing SEM equipment in structure list|NOCO ATCO NOTE|SEM equipment not put in structure list|Assembly |Component Traceability Not Maintained|SS - Controls -SCM  hyd/mech components|Control Valve|Documentation Requirement |Process step not followed / detected
ZF|P6000088604|16/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Other causes/damage |No Non-Compliance
ZB|P6000042969|25/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 15|ATCO NOPT NOTE NOCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000103208|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7103234|16/02/2001|priority 4 |Q3|Unknown|Unknown|SCM PTs to be upgraded/tested|NOCO ATCO NOPT NOTI|Supplier design error|103-Electrical|Pressure Transducer|Ext. loc. - KOS Houston|Work Shop|Root cause Vendor|Design error
ZF|100056443|01/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|Troll SCM#4 SEM A DHI204 Current Reading|ATCO NOTE NOCO NOPT|WD calibration data accidentally deleted|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Operator Error
Q3|100001156|05/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM SEM A  no comms with DHPG. SEM B ok|NOPT ATCO NOTI NOCO|Not yet known  SCM still subsea|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Deepsea Trym|Initial/Direct product problem|Function
ZF|100035400|16/08/2004|priority 3 |Q3|Unknown|Unknown|FAIL DISCOVERED DURING TESTING OF CITV|NOTE NOPT NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000055605|08/01/2015|priority 3 |Q3|Unknown|Unknown|Increase in pressure on PT 18|ATCO NOPT NOTE NOCO|Followed up in QN 200421055|Test Related |OBS-Component Error|SS - Controls - Hydraulic Products|Other Hydraulic Products|Vendor related |Specification not followed
ZB|100048038|14/02/2009|priority 3 |Q1|CHEVRON|WEST AFRICA|circulations pump failure due to degrade|ATCO NOCO NOTE|circulations pump failure due to degrade|Test Related |OBS-Function|Control System Topside Hydraulic Eq.|Hydraulic Power Unit (HPU)|FMC Other causes/damage |Damage from Wear and Tear
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 07|ATCO NOPT NOCO NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000108984|28/11/2013|priority 3 |Q3|Unknown|Unknown|Threads on outercan to short|NOTE NOPT NOCO ATCO|Interface with EC adapter verified OK|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |No Non-Compliance
ZF|100037967|25/01/2006|priority 1 |Q3|BP|Unknown|Wrong baseplate assembled on SCM|NOTE ATCO NOCO NOPT|failure of routine by new personnel|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Materials/Stores related |Improper Handling
ZB|100001156|18/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|SCM-2 L-4H GFC AI card SEMA malfunct.|ATCO NOCO NOPT NOTE|Failure in AI Card|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Compl. & W.Over - XT - R. Tools|Xmas Tree Running Tool for CXT|FMC Materials/Stores related |Operator Error
Q3|3812476|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|SCM to be upgraded|NOCO NOPT ATCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Function
Q3|7102643|20/03/2001|priority 3 |Q3|Unknown|Unknown|SCM PT incorrect reading of valve status|NOPT NOTI ATCO NOCO|Not yet known|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
ZB|100048038|13/12/2007|priority 2 |Q1|CHEVRON|WEST AFRICA|NO COMMUNICATION WITH A SIDE ADDRESS|NOCO NOTE|Unknown|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor related |Component error
ZF|100046112|14/10/2005|priority 3 |Q3|WOODSIDE|Unknown|WRONG WIRING OF EC|NOTE NOCO NOPT ATCO|Incorrect wiring.|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100056176|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO|Unknown|Project|Project Requested Unfinished shipment|FKS Quality system issues|Resource Management|FMC Other causes/damage |Planning error
ZF|P6000042308|07/05/2009|priority 3 |Q3|Unknown|Unknown|Oversized holes for config. plugs|NOTE ATCO NOPT NOCO|Non-Compliance handled in Qn 200117134|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZE|P7000016420|15/10/2018|priority 2 |Q3|PETROBRAS|Unknown|p7000016422 2018-04-09 pdg do ro-168 não|OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|3794920|04/07/2007|priority 2 |Q3|STATOIL|NORTH SEA|SENSOR PT ANN NO READINGS ON ETU|NOPT ATCO NOCO NOTE|SCM was repaired|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
ZF|7104075|25/10/2005|priority 3 |Q3|MARUBENI|GOM|FAILURE TO MEET ACCEPTANCE CRITERIA|ATCO NOCO NOPT NOTE|Component failure|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|100020562|22/07/2009|priority 3 |Q3|BP|GOM|SKOFLO SCM SN #1  Wiring|NOCO NOTE ATCO NOPT|SKOFLO SCM SN #1 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000076121|03/10/2011|priority 3 |Q3|CNOOC|Unknown|PT outside accept criteria|ATCO NOPT NOCO NOTE|Cause not found  QN200236529&QN200239524|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000083428|10/09/2012|priority 3 |Q3|Unknown|Unknown|HC72 to be replaced with blind coupler|ATCO NOPT NOTE NOCO|BOM needs update. Wrong PN on HC72|Change/Deviation Request |Part substitution request|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Continuous Improvement
ZF|P6000055605|22/06/2011|priority 3 |Q3|SHELL|GOM|Wiring mistake on EC 7|NOPT ATCO NOTE NOCO|Human Error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100020562|25/06/2004|priority 3 |Q3|Unknown|Unknown|PT/TT  Simulator is not working|NOCO NOPT NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|100035119|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|NOCO ATCO NOTE|Enfield - SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000069056|06/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No failure detected in extended testing|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100018082|11/03/2013|priority 1 |Q3|Unknown|Unknown|Wrong ref. in FAT for Mikkel SCM|NOCO NOTE ATCO|Wrong ref. in FAT for Mikkel SCM|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P7000000897|12/11/2015|priority 3 |Q3|SHELL|Unknown|MMR - Coating Refurbishment|NOTE NOPT ATCO NOCO|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|Other external causes |Customer Error/responsibility
ZE|100035119|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|ATCO NOTE NOCO|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000103208|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q1|7102643|28/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 35  Well R-1H Hyd. leak HP circuit|NOTI ATCO NOPT NOCO|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Leakage
ZB|7102969|21/03/2007|priority 3 |Q1|Unknown|Unknown|Electrical Flying lead stuck on SCM Elec|NOTE ATCO NOCO|Follow procedures and process|Damage |Damage from corrosion|Subsea Control Module (SCM) Electrical|ROV el. connectors|FMC Other causes |Logist.-Handling/Packing/Shipping error
Q3|7101172|21/09/2000|priority 2 |Q3|Unknown|Unknown|SCM hydraulic leak  21-95 l/d  well F-4H|NOTI NOCO NOPT ATCO|See QN 200008814|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Leakage
ZF|100037427|30/09/2005|priority 1 |Q3|TOTAL|WEST AFRICA|Return compensator retest SCM I02|NOTE NOPT ATCO NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100034629|15/09/2004|priority 3 |Q3|STATOIL|Unknown|EL. CAN IS STUCK|ATCO NOPT NOTE NOCO|Unknown|Assembly / Test related |Dimension (tolerance)|Subsea Control Module (SCM) Mech w/MB|One atmosphere canisters|FMC Engineering related|Design Specification/Drawing error
Q3|7104033|24/02/2000|priority 4 |Q3|Unknown|Unknown|All SCMs to have hyd. flow restrictors|NOPT ATCO NOTI NOCO|Instructions from system engineering|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZE|100056918|04/05/2013|priority 2 |Q3|Unknown|Unknown|ENFIELD- SCM Fault|ATCO NOTE NOPT NOCO|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|7102643|02/04/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOPT NOCO ATCO NOTE|Wear and tear.|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|P6000093501|07/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000132097|13/12/2016|priority 3 |Q3|Unknown|Unknown|SIIS level 2 flying master|ATCO NOTE NOCO|Unknown|Change/Deviation Request |Conversion approval|Object Types to Eng Matl CLASS|press_temp_transmitter|FMC Other causes/damage |Cause not found
ZF|100031223|04/08/2006|priority 3 |Q3|STATOIL|NORTH SEA|Leakage in hydraulic coupler.|NOPT NOCO NOTE|Unknown|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Assy |Missing Operation
ZD|P6000088751|14/02/2016|priority 4 |Q2|Unknown|Unknown|GWF/Missing protection cap|NOPT ATCO NOCO NOTE|Unknown|Procurement |Part Not Protected As Per DBI|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
Q3|7101172|08/11/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOPT NOTI NOCO ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZD|100020278|06/05/2010|priority 3 |Q2|EXXONMOBIL|Unknown|Megi 35|ATCO NOPT NOTE NOCO|Procedure Concerns|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|7104075|12/08/2011|priority 3 |Q3|Unknown|Unknown|SCM filter change document conflict|NOTE NOCO ATCO NOPT|SCM filter change document conflict|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100046112|15/11/2011|priority 1 |Q3|WOODSIDE|Unknown|(SS) MMR- DHI109 board found burnt|NOPT NOCO NOTE ATCO|DHI 109 board found burnt capacitor|Damage |Damage during testing|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Operator Error
ZB|P6000064909|02/04/2014|priority 2 |Q1|Unknown|Unknown|LT NCR 25: SCM Software|NOCO NOTE ATCO|Unknown|Design |Specification Error|Customer Compliant|Unsatisfactory Customer Satisfaction|FMC Engineering related |Specification error
Q3|7101172|10/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|Possible defect 4-20mA interface SEM A|NOPT NOTI ATCO NOCO|AD Converters too old rev. on AI150 card|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Gullfaks A|Initial/Direct product problem|Function
ZF|P6000104111|13/03/2014|priority 3 |Q3|Unknown|Unknown|SEM taking too long to get communication|NOTE NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Specification error
ZF|P6000042969|22/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|HC 51 is leaking oil|NOTE NOCO NOPT|Design error  will be repaired in ZD QN|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |DBI error
ZF|P6000105542|13/02/2014|priority 3 |Q3|Unknown|Unknown|MRMS on Line A not working|ATCO NOCO NOPT NOTE|SCM to be returned to KBG for repair|Test Related |OBS-Function|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Other causes/damage |Cause not found
ZF|P7000024900|17/01/2013|priority 1 |Q3|Unknown|Unknown|Connectors inverted|NOCO ATCO NOTE NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100029062|09/03/2011|priority 1 |Q3|TOTAL|Unknown|Hydraulic test on SCM Prod 07 failed|NOCO NOPT ATCO NOTE|Sensor reading failled|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Programmer Error
ZC|100036936|22/04/2005|priority 2 |Q2|STATOIL|NORTH SEA|Not performed HFT do to lack of time|ATCO NOCO NOTE NOPT|PSM not followed  short mob time|Assembly/Test Related |Do Not Use|FKS Quality system issues|Resource Management|FMC Assy |Missing Operation
ZB|7101172|18/03/2009|priority 4 |Q1|STATOIL|NORTH SEA|SCM 25  GFA D-1H  LP int.leak PWV &SCSSV|NOPT NOTE NOCO|Leakge in SOV|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Other causes/damage |Damage from Wear and Tear
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|Unknown|Too high cracing pressure on check valve|NOPT NOTE NOCO|Cracing pressure not verified on SCM|Assembly / Test related |Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Procedure error
ZF|100050519|03/07/2006|priority 3 |Q3|MOHO BILONDO|Unknown|DHI values on wrong index on ETU|ATCO NOPT NOTE NOCO|failure to follow procedures|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Lack of Training
ZD|100034440|10/09/2005|priority 3 |Q2|Unknown|Unknown|Missing Documentation|NOTE NOCO ATCO NOPT|Documents errors|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
ZF|100026328|22/05/2003|priority 3 |Q3|PETROBRAS|Unknown|FAIL WITH EL. CARD|ATCO NOCO NOPT NOTE|Missing wiring connection.|Assembly / Test related |Material Faulty|Subsea Control Module (SCM) Electrical|Wiring|FMC Engineering related|Design Specification/Drawing error
ZF|7102969|07/03/2006|priority 3 |Q3|EXXONMOBIL|Unknown|FAILURE TO OPPERATE TO PRD REQUIREMENTS|NOTE NOPT ATCO NOCO|SILICONE CHECK VALVE FAILURE|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZD|P6000039844|06/11/2009|priority 1 |Q2|SHELL|Unknown|(SS) Wrong Marking on SCM|NOTE NOCO NOPT|Unknown|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZB|100036936|19/02/2009|priority 4 |Q1|STATOIL|NORTH SEA|F&D Not possible to communicate SEM A-B|NOCO ATCO NOPT NOTE|SCM did not work as intended|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage during transport
ZF|100020562|31/10/2005|priority 2 |Q3|BP|GOM|DAMAGE TO EC7 ELE CONNECTOR|NOTE NOCO NOPT ATCO|EC7 CONNECTOR DAMAGED|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Logist.-Handling/Packing/Shipping error
ZE|P6000069056|04/11/2011|priority 3 |Q3|Unknown|Unknown|Wrong config shown in Software document|ATCO NOCO NOTE NOPT|Error in document LST60062051  rev A|Unknown|Unknown|SS - Controls -Computer system software|SEM/TPU config|Causes for Improvement|Documentation
ZD|P1000004979|10/08/2005|priority 3 |Q2|Unknown|Unknown| Subsea Control Module Software|NOPT NOTE ATCO NOCO|Software design parameters|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
Q1|7103233|13/03/2003|priority 3 |Q1|SUNCOR NGXT|Unknown|SCM 08P TNO SEMB LP Ret. malfunction|NOPT NOTI NOCO|Unknown|102-Hydraulic|Flowmeter|Ext. Loc. - St.Johns (Canada)|Work Shop|Initial/Direct product problem|Function
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|Unknown|Gluing of DHI212 board|ATCO NOCO NOTE|WD design improvement.|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000058949|14/09/2010|priority 1 |Q3|Unknown|Unknown|Feil luping  fra Hp til Lp|NOPT NOCO NOTE ATCO|Not correct marking on test equipment|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000088614|14/05/2014|priority 3 |Q3|Unknown|Unknown|To small holes in the wedge disk|ATCO NOCO NOTE NOPT|Hole size error  follow-up QN200377517|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Vendor related |Specification not followed
ZF|P6000104116|27/11/2014|priority 3 |Q3|Unknown|Unknown|Not completed threads  DIU16|NOPT NOTE ATCO NOCO|Unfinished threads|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZB|100026328|11/05/2016|priority 2 |Q1|Unknown|Unknown|Viola Claim 001 SCM #07|NOTE NOCO ATCO|Suspect failure at CBV.|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000083428|13/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000063531|27/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|CPU600 improving startup on long umbilic|ATCO NOCO NOTE|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZE|P6000076121|05/02/2013|priority 2 |Q3|Unknown|Unknown|LH4-1 E1 SCM voltage high|NOTE NOCO ATCO|E1 SCM voltage high|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
Q3|7104075|19/09/2001|priority Unknown|Q3|Unknown|Unknown|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|NOCO NOPT ATCO NOTI|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Design Specification error
ZF|P7000039672|04/02/2014|priority 1 |Q3|Unknown|Unknown|Ausência dos printout - Ctrl valve reset|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missing Parts
ZF|P6000093498|29/07/2014|priority 2 |Q3|Unknown|Unknown|Missfitting el-can for SUPS|ATCO NOTE NOPT NOCO|Housing SEM620 selected not SUPS housing|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000088626|19/07/2017|priority 3 |Q3|Unknown|Unknown|Traceability miss match  non complience|ATCO NOCO NOTE|CER-0000020742 has wrong SN|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Marking |Incorrect Marking
ZF|100006609|06/09/2011|priority 1 |Q3|Unknown|Unknown|PARAFUSO NÃO TORQUEADO CORRETAMENTE|NOTE NOCO ATCO NOPT|Unknown|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Missing Operation
ZF|P7000001621|29/05/2018|priority 4 |Q3|PETROBRAS|Unknown|MMR - Compensator Bladder Leakage|NOCO ATCO NOTE|Unknown|Damage |Damage during assembly|Object Types to Eng Matl CLASS|scm_components|FMC Assy |Damaged during assembly
ZB|7106268|05/07/2004|priority 2 |Q1|TOTAL|Unknown|SCM 02 I/WDHI SEM A no comunication|ATCO NOPT NOCO NOTE|Jumper not properly connected..|Assembly / Test related |Function|Subsea Control Module (SCM) El. act.syst|Control electronics|Vendor audit related|Unknown
Q3|7102643|17/10/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|NOPT NOCO ATCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|100020278|20/01/2011|priority 2 |Q3|EXXONMOBIL|Unknown|Missing Sign offs|NOTE ATCO NOCO NOPT|Missing Sign Offs|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Electrical Components|Intercompany|FMC Houston
ZF|100030542|09/10/2007|priority 3 |Q3|Unknown|Unknown|SCM Plug is wrongly installed|NOPT NOCO NOTE|Part can be used as installed.|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
Q3|7100320|12/12/2001|priority 3 |Q3|PETROBRAS|Unknown|SCM 15 Hercules Extension rod defect|NOTI NOCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Function
ZF|P6000051036|01/06/2010|priority 2 |Q3|BP|Unknown|Manifold block redirected to Germ SCM 02|NOTE NOCO|redirection of m.block due to logistics|Documentation |Incorrect Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Documentation error
ZF|P6000065886|15/12/2010|priority 2 |Q3|Unknown|Unknown|Compensator assy fault|NOPT NOTE NOCO|BOM error|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOPT NOCO ATCO NOTE|Dial caliper coupler measurements|Machining Related |OBS-Angle error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100049000|05/03/2009|priority 3 |Q3|BP|GOM|SCM-Address Error on Nameplate|NOPT ATCO NOCO NOTE|SEM Address Error on Nameplate|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|100046112|23/11/2005|priority 3 |Q3|WOODSIDE|Unknown|Wrong interface-debris cap and test hose|NOTE NOCO NOPT ATCO|Interface problem test equipment / SCM|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
Q3|3794920|03/02/2000|priority 3 |Q3|Unknown|Unknown|No contact with SCM sensors  offshore|NOCO NOTI NOPT ATCO|No fault found at KOS KBG  SCM re-sent|103-Electrical|Modems/Communications|Defect locations - offshore/field|Viking Poseidon|Initial/Direct product problem|Function
ZF|P7000024900|15/02/2013|priority 2 |Q3|Unknown|Unknown|Scratches on Adapter Plate for cvlp|ATCO NOPT NOCO NOTE|Scratches on Adapter Plate for cvlp|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Cause not found
ZF|100035013|17/12/2008|priority 2 |Q3|SHELL|Unknown|cannot seal outer can to SCM|ATCO NOCO NOTE NOPT|metal debris left in the o-ring groove|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|P6000080733|14/05/2014|priority 1 |Q1|Unknown|Unknown|Fram H Nord Claim SCM 02|ATCO NOTE NOCO|Break in connection|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|P6000125392|13/05/2017|priority 2 |Q3|Unknown|Unknown|HFT for ROSA SCM is wrong|ATCO NOTE NOCO|Error in HFT  Inhouse and FAT.|HP supply pressure to high|Documentation Requirement |Incorrect user documentation (customer)|Object Types to Eng Matl CLASS|SCM (all types of Control Modules)|Documentation Requirement |Procedure error
ZD|P6000068912|30/07/2013|priority 2 |Q2|Unknown|Unknown|Missing Valve Cap P/N:100014108 from SCM|ATCO NOCO NOTE NOPT|Missing Protection Cap|Marking |No Marking|SS - Controls -SCM Test Stand|Hydraulic Couplers|Intercompany|FMC Kongsberg
ZF|P6000104111|20/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100020562|19/10/2010|priority 2 |Q3|BP|GOM|Material not delivered to plant|NOPT ATCO NOCO NOTE|Material  not delivered to plant|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Houston
ZF|100035118|02/11/2005|priority 3 |Q3|PETRONAS|Unknown|Fluid flow from WOCM return|NOCO ATCO NOTE NOPT|no failure found|Assembly/Test Related |Function|SS - Compl. & W.Over - Workover/Riser|Unknown|FMC Assy |Missing Operation
ZF|P6000042968|04/09/2009|priority 1 |Q3|TOTAL|WEST AFRICA|P/N7104715  hydraulic coupler|NOCO NOTE ATCO NOPT|PO not updated|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |ECN Change
ZB|100006609|21/11/2013|priority 3 |Q1|PETROBRAS|Unknown|RTA MEQS/2013/0037A|ATCO NOCO NOTE|Falha da demanda de manutenção do SCM|FMC Other Defect |Physical|Subsea Control Module (SCM) Hydraulic|Hydraulic couplers|FMC Fabrication Shop Equipment |Lack of Maintenance
Q1|7102643|06/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 12 ÅsgA P-1H PT Func. PMV malfunct.|NOTI NOPT NOCO ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Function
Q1|100018600|06/02/2003|priority 2 |Q1|Unknown|Unknown|Petrobras reject all SCM's|NOTI NOCO NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000093498|27/05/2014|priority 3 |Q3|Unknown|Unknown|Tubing too long|NOTE ATCO NOPT NOCO|Drawing corrected  S/N req. SCM tubes|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
Q3|7103233|09/12/1999|priority Unknown|Q3|Unknown|Unknown|CIDV test results out of accept criteria|ATCO NOPT NOTI NOCO|Testing method is not correct|102-Hydraulic|Chemical Control Valves|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Documentation
ZF|P6000068912|15/04/2013|priority 2 |Q3|Unknown|Unknown|Loss of communication on stack-up test.|NOTE NOCO|Cause to be stated in SO 1240922|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000024900|14/08/2012|priority 1 |Q3|Unknown|Unknown|Alteração de valores.|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZF|P6000068912|08/03/2013|priority 2 |Q3|Unknown|Unknown|S/N 6 was sent to Dunfermline|NOTE ATCO NOCO ORAS|TP and CPUboard error followupQN created|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100020562|14/02/2006|priority 2 |Q3|BP|GOM|FAILURE TO OPPERATE TO PRD REQUIREMENTS|NOPT ATCO NOCO NOTE|CHECK VALVE OPERATES CORRECTLY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q3|100017305|14/01/2003|priority 3 |Q3|STATOIL|Unknown|SCM is leaking silicone oil.|NOCO NOTI NOPT ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P6000100953|26/06/2013|priority 3 |Q3|Unknown|Unknown|Wrong in new config|NOPT NOTE ATCO NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Procedure error
ZF|P6000031350|22/04/2009|priority 3 |Q3|STATOIL|NORTH SEA|Water in silicon after hyperbaric test|NOCO NOTE NOPT ATCO|No errors found in test|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|100049000|04/04/2006|priority 3 |Q3|BP|GOM|HFT DISCREPENCY|ATCO NOCO NOTE NOPT|HFT Instructions Issues|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100036936|06/11/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC (3 EA)|ATCO NOPT NOTE NOCO|Unknown|Damage |Wear & Tear|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |Cause not found
ZE|P6000091085|13/05/2016|priority 4 |Q3|Unknown|Unknown|OWIRS Deadman Sequence - Cancelled|NOTE NOPT NOCO|Cancelled|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Process/Procedure Ineffective
Q3|7105597|Unknown|priority 2 |Q3|Unknown|Unknown|Siliconoil  draining  refilling.|NOPT NOTI NOCO ATCO|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Operation & Maintenance Manual (OMM)
ZF|100037229|08/10/2018|priority 3 |Q3|PETROBRAS|Unknown|MMR - Broken Screw Bladder Assembly|NOPT ATCO NOCO NOTE|Unknown|Assembly |Over Torqued|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000039672|29/05/2013|priority 1 |Q3|Unknown|Unknown|Missing O-Ring from top/bottom WedgeDisk|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|P6000116166|03/09/2014|priority 4 |Q3|Unknown|Unknown|Wrong lenght on tube PN P6000038406|NOCO NOTE NOPT ATCO|Wrong length on tube from bending work|Machining Related |OBS-Length/Depth Error|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|Vendor related |Specification not followed
ZF|P6000091085|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000084906|12/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7103233|Unknown|priority 1 |Q3|Unknown|Unknown|SIO card errors during low temp. test|NOTI NOPT ATCO NOCO|SIO fault in the freeze test.|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Function
Q1|7103234|03/01/2003|priority 2 |Q1|Unknown|Unknown|TNO SCM 06I HP internal leak|NOTI NOCO ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|FPSO Terra Nova|Initial/Direct product problem|Leakage
Q3|7103234|Unknown|priority 3 |Q3|Unknown|Unknown|Min. flow test results out of limits|NOPT NOTI NOCO ATCO|Unknown|Product defects for dept. 1640|1641 SCM (Mech) Flow Meter|Defect locations - onshore|KOS Kbg. SCM-FAT|Initial/Direct product problem|Function
ZF|P6000074156|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOPT ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000069056|16/07/2013|priority 1 |Q3|Unknown|Unknown|SCM not mobilized acc. to FMC procedure|NOPT NOCO ATCO NOTE|Time constraint|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|7103233|15/06/2005|priority Unknown|Q3|OVERALL PROJECT ROLL-UP|Unknown|SIO failure ?|NOTE NOCO NOPT|Not known.|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
Q3|7101463|25/06/2002|priority 3 |Q3|MOBIL EG|Unknown|DHI-failure|NOTI ATCO NOCO NOPT|Unknown|103-Electrical|Printed Circuit Board|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Function
ZF|P6000068770|05/02/2015|priority 2 |Q3|Unknown|Unknown|Item used without inspection|NOTE ATCO NOCO NOPT|Equipment used without IMDR|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P6000074156|06/12/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOPT NOTE|No SEM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|NOPT ATCO NOTE NOCO|HFT DOC. & TEST UNIT DISCREPANCY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZF|100020562|12/05/2005|priority 1 |Q3|BP|GOM|SCM 18 4-20 ma readings out of spec.|NOPT NOTE ATCO NOCO|"RIT failure on SEM ""A"""|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |QN Cancelled
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO NOPT|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-014: AIB Voltage Reference Error|NOTE NOCO|AIB Vol Ref Error|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000037215|04/05/2011|priority 2 |Q3|ENGIE|NORTH SEA|Actuator leakage|NOCO ATCO NOTE|Bad workmanship during installation|Damage |Damage Due to Handling|SS - Controls - Electric Products|Other Electric Products|Vendor related |Operator Error
Q3|7104075|Unknown|priority 2 |Q3|Unknown|Unknown|Dårlig kontakt i gjennomføringer i tank.|ATCO NOCO NOPT NOTI|Unknown|Product defects for dept. 1640|1641 Test equipment|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZF|P6000029747|04/09/2009|priority 1 |Q3|GJØA|Unknown|P/N7104715  hydraulic coupler|ATCO NOPT NOTE NOCO|ECN Class 1 should be Class2|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |ECN Change
ZF|P6000055198|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|100025337|28/11/2002|priority 1 |Q3|Unknown|Unknown|Return line bent incorrectly|NOPT ATCO NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100017997|19/07/2010|priority 1 |Q3|BP|Unknown|Cor-pro didn't coat can IWOCS 2 correct|NOTE ATCO NOPT NOCO|Cor-pro didn't coat IWOCS 2 can correctl|Coating/Plating |Coating defect|SS - Controls - WOCS|Installation Workover Control System (IW|Vendor related |Coating Defect
ZF|P7000039672|08/10/2013|priority 1 |Q3|Unknown|Unknown|ECN  6147855 - PN  P7000039672|NOPT ATCO NOCO NOTE|ECN|Design |DBI Error|SS - Controls -Hydraulic Distribution|Other hydraulic components|FMC Engineering related |ECN Change
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|Unknown|Possible chips inside the HP-Config Plug|ATCO NOCO NOPT NOTE|Plugs not cleaned by supplier.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
Q3|100018600|21/01/2003|priority Unknown|Q3|PETROBRAS|Unknown|Power supply failure|NOTI ATCO NOCO NOPT|Short cicuated tantalum capacitor|103-Electrical|SEM Powersupply|Unknown|Unknown|Unknown|Unknown
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|SCM11 connector damaged|NOTE NOCO ATCO|Unknown|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Other causes/damage |QN Cancelled
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|Unknown|Trafo problems on Agbami S/N 25|NOTE NOCO ATCO NOPT|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
Q3|7100320|02/12/1999|priority 3 |Q3|Unknown|Unknown|Oppgrader Hercules 10-BETA til 10-OMEGA|ATCO NOTI NOCO NOPT|Unknown|Product defects for dept. 1640|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Unknown|Unknown
ZF|P7000039672|05/09/2018|priority 1 |Q3|Unknown|Unknown|ECN  7090703    PN  P7000017838|NOCO NOTE ATCO NOPT|Error-concept/calculation|Design |DBI Error|Object Types to Eng Matl CLASS|kits|FMC Engineering related |ECN Change
ZF|100038200|02/06/2005|priority 3 |Q3|Unknown|Unknown|RS 485 failure to read on ETU SCM63|ATCO NOCO NOTE NOPT|Failure during RIT test procedures|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000088604|01/02/2013|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOPT NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000031350|20/04/2009|priority 2 |Q3|STATOIL|NORTH SEA|Process problems|NOCO NOTE NOPT|Travellers not delivered with boards|Documentation |Missing Certificates / Records|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Unknown
ZF|100035118|13/07/2005|priority 3 |Q3|PETRONAS|Unknown|Unable to control COVHP from SEM A|ATCO NOPT NOTE NOCO|Incorrect wiring|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 24|ATCO NOPT NOTE NOCO|Investigate Coupler Rotation-BPAT SCM 24|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|100034440|04/10/2005|priority 2 |Q3|HOUSTON STOCKING MK IV|Unknown|THREADS WERE DAMAGED DURING ASSEMBLY|NOTE ATCO NOPT NOCO|Incorrect threads on plugs.|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Fabrication error
Q1|7101401|23/11/1999|priority Unknown|Q1|Unknown|Unknown|Request for SCM lower skirt & latch unit|NOPT NOCO NOTI ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|100025661|24/11/2011|priority 3 |Q3|Unknown|Unknown|Wiring mistake on COV HP|ATCO NOTE NOCO|Engineering error.Procedures not updated|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|Projects Related|Documentation error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE ATCO NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZD|P6000084242|13/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PARTNUMBER|ATCO NOCO NOPT NOTE|INCORRECT PARTNUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
Q2|7102643|Unknown|priority 3 |Q2|Unknown|Unknown|LP Ventiler harhatt HP på pilotsteget.|NOCO NOTE NOPT ATCO|Unknown|Product defects for dept. 1640|1641 SCM (Mech) Valves|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Problem causes  defect causes|Production
ZF|7102643|28/01/2004|priority 2 |Q3|STATOIL|NORTH SEA|AS FD 86  Lock-ring for Tronic connector|NOPT NOCO NOTE|Unknown|Vendor related|Unknown|Subsea Control Module (SCM) Electrical|ROV el. connectors|Vendor related|Material error
ZE|7102969|25/04/2005|priority 3 |Q3|MOBIL EG|Unknown|(change to ZF)|NOTE NOCO ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|Not performed HFT do to lack of time|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000088751|09/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|NOPT ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000104116|18/03/2015|priority 3 |Q3|Unknown|Unknown|Damage on Sem Housing|ATCO NOCO NOPT NOTE|Machining error not acc. surface finish|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 18|NOPT NOCO NOTE ATCO|Investigate Coupler Rotation-BPAT SCM 18|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZB|100048038|05/12/2006|priority 1 |Q1|CHEVRON|WEST AFRICA|RPXT SCM #4 leaking fluid|NOTE ATCO NOPT NOCO|RPXT SCM #4 leaking fluid|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Vendor related |Component error
ZB|P6000058949|12/02/2013|priority 1 |Q1|Unknown|Unknown|Gullfaks Claim 220 SCM (615)|ATCO NOTE NOCO|CPU boards failed|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZE|100020562|10/05/2010|priority 3 |Q3|Unknown|Unknown|Escape: Controls Data Books|NOCO NOTE|See Orange Event - 200129497|Unknown|Unknown|SS - Controls - Sensors|SCM Pressure Transmitter (PT)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000098616|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100035014|19/10/2010|priority 2 |Q3|STATOIL|Unknown|Material not delivered to plant|NOCO NOTE|Unknown|Documentation |Incorrect user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZD|100037428|23/05/2009|priority 2 |Q2|Unknown|Unknown|CERT ISSUE|NOTE NOCO ATCO|NVL - Missing Certification|Documentation |Missing Certificates / Records|SS - Compl. & W.Over - XT - General|Tree Assembly|Vendor related |Operator Error
ZF|P6000093498|01/08/2016|priority 2 |Q3|RLWI STACK 4|Unknown|RLWI SN 01  Baseplate contamination|ATCO NOCO NOTE|corrosion particles punchured bladder|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - WOCS|Installation Workover Control System (IW|FMC Other causes/damage |Damage from Wear and Tear
ZE|P6000068924|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update SRM PSM - Luanda Workshop|NOTE NOCO ATCO|Operator write N/A  doc. not updated|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|100049000|09/09/2009|priority 2 |Q3|BP|GOM|BP Atlantis (DHFC) SCM 05|ORAS NOTE NOCO|Wrong fluid type|Test Related |OBS-Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
Q3|7100320|20/11/2001|priority 3 |Q3|PETROBRAS|Unknown|SCM Hercules LP Leak/SEM A AI150 malfunc|NOTI NOCO NOPT ATCO|HP control valves  excessive leakage|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Leakage
ZF|P6000073687|30/03/2012|priority 3 |Q3|FRADE BVFRADE PH II|Unknown|wrong insulation sheet ++|NOPT NOTE ATCO NOCO|Error in BOM at Kitron|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Vendor related |Wrong Part Delivered
ZE|100025661|09/05/2017|priority 4 |Q3|Unknown|Unknown|PSM20018386 Update|NOCO NOPT ATCO NOTE|Procedure Improvement - PSM update|Unknown|Unknown|SS - Controls - Topside Products|Subsea Control Unit (SCU)|Causes for Improvement|Process/Procedure Ineffective
ZF|P7000016420|22/11/2011|priority 1 |Q3|Unknown|Unknown|conector de base danififcado|NOCO ATCO NOPT NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Operator Error
ZB|100066325|04/10/2016|priority 1 |Q1|Unknown|Unknown|Statfjord GC 187795 Connector PT sensors|NOCO ATCO NOTE|Rejected no fault found|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Assembly |Other- Specify in comments
ZF|P6000093498|27/10/2014|priority 2 |Q3|Unknown|Unknown|PSD600-1 -CAN BUS Communication Fails|ATCO NOPT NOTE NOCO|Opr mistake  Incorrect wire clamping|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100025661|21/03/2006|priority 3 |Q3|SHELL|GOM|LEAK ON INTERNAL  ACCUMULATOR N2 LINE|NOCO NOPT NOTE ATCO|Int. Accumulator N2 Line leak  handling?|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|7103234|11/05/2007|priority 2 |Q3|Unknown|Unknown|No feedback from sensors|NOCO NOTE NOPT|See SN 300162480|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZF|P6000105542|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|ATCO NOPT NOTE NOCO|HFT DOC. & TEST UNIT DISCREPANCY|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Vendor design error
ZE|P6000042308|13/04/2010|priority 4 |Q3|TULLOW|WEST AFRICA|Escapes: Procedure update W/O ECN|ATCO NOCO NOTE|Unknown|Unknown|Unknown|SS - Controls - Topside Products|N/A SW|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000042969|13/05/2009|priority 1 |Q3|Unknown|Unknown|Cards fails to read gauges|NOPT NOCO NOTE|Error to be confirmed in QN200128479|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Unknown
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|ATCO NOPT NOCO NOTE|Coupler Interface on m.block (spc error)|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Specification error
Q3|7104020|Unknown|priority 3 |Q3|Unknown|Unknown|Error in wiring diagram DWG-211635|NOTI ATCO NOPT NOCO|Unknown|Product defects for dept. 1640|1641 SCM (El) Electric Rack|Defect locations - onshore|KOS Kbg. SCM-In-house FAT|Initial/Direct product problem|Documentation
ZF|100037428|15/03/2005|priority 2 |Q3|TOTAL|WEST AFRICA|Wrong readings detected during EFAT|NOCO NOPT ATCO NOTE|Unknown|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000104112|09/05/2014|priority 3 |Q3|Unknown|Unknown|Power level verificaition fiber failed|NOCO NOPT NOTE ATCO|Follow-up through QN 200380489|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Clarification
ZF|P6000105708|21/01/2015|priority 3 |Q3|Unknown|Unknown|Sourcing not set up correctly|NOTE ATCO NOCO|Sourcing not set up correctly|Documentation |Procedure / Process Error|SS - Controls - Topside Products|Other Topside Products|FMC Test |Missed operation
ZF|P6000103208|17/02/2014|priority 3 |Q3|Unknown|Unknown|Possible gas leakage in SCM|ATCO NOPT NOTE NOCO|Pressure increase due to temperature|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZD|7103233|05/10/2010|priority 1 |Q2|SUNCOR|Unknown|Adaptor Plate & Manifold Bolting Change|ATCO NOTE NOPT PAGE NOCO|Vendor Liability|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P7000000897|09/05/2012|priority 1 |Q3|Unknown|Unknown|Flow meter - HP Supply|NOCO ATCO NOTE NOPT|Equipamento retornou do campo|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |Damage from Wear and Tear
ZF|100037965|16/12/2005|priority 3 |Q3|BP|Unknown|SCM hydaulic cleanliness out of spec.|ATCO NOCO NOPT NOTE|SCM contaminated by external equipment|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P7000001621|12/06/2010|priority 1 |Q3|Unknown|Unknown|Teste de Pressão Manifold Block 03 - LP|NOCO NOPT NOTE ATCO|Test Stand não suporta pressão indicada|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000020444|19/07/2011|priority 1 |Q3|Unknown|Unknown|Etapas do procedimento não realizada|NOPT NOTE NOCO ATCO|Etherscope não funcional|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P7000039672|14/12/2018|priority 2 |Q3|Unknown|Unknown|Tube Vacuum small and Test High Pressure|NOCO NOPT ATCO NOTE|Unknown|Assembly |Dimension (tolerance)|Object Types to Eng Matl CLASS|scm_mkIIE|Assembly |Damaged During Assembly
ZF|P7000039672|03/02/2015|priority 1 |Q3|Unknown|Unknown|Falta de o-rings|NOCO NOTE NOPT ATCO|Unknown|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P6000116360|14/01/2016|priority 3 |Q3|Unknown|Unknown|SCM clashes with MRT|ATCO NOCO NOTE|DWG-0223681-001 needed to be updated|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000068912|23/06/2011|priority 3 |Q3|Unknown|Unknown|PT/TT Sensors Calibration and startup|ATCO NOCO NOTE NOPT|DBI error|Test Related |OBS-Component Error|SS - Controls - Test and Transportation|Sensor Simulator (SESI)|FMC Engineering related |DBI error
ZF|P7000016420|07/12/2011|priority 1 |Q3|Unknown|Unknown|MARCAÇÃO DA RASTREABILIDADE|NOCO ATCO NOTE NOPT|CAUSA VENDOR|FMC Other Defect |Physical|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|Vendor related |Specification not followed
ZF|P7000039672|16/10/2013|priority 4 |Q3|Unknown|Unknown|SRT - Pre-Salt #12 - Relay 2|NOCO NOTE NOPT ATCO|PO 47636681 - 117094 FMC KONGSBERG SUBSE|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Intercompany|FMC Kongsberg
ZF|P7000039672|11/10/2013|priority 1 |Q3|Unknown|Unknown|Marcação SCM com erros de Escrita.|NOCO NOPT ATCO NOTE|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Paintshop Related|Operator error
ZF|P6000101955|17/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000063632|23/12/2010|priority 1 |Q3|AQUILA PHASE 2|Unknown|CPU600 improving startup on long umbilic|ATCO NOCO NOTE NOPT|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|100034440|30/11/2010|priority 2 |Q3|POGO|GOM|Class 1 ECN 6083510|ATCO NOPT NOCO NOTE|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000057855|07/12/2010|priority 2 |Q3|ENI|Unknown|TIF ping test fails - packet loss > 1%|NOTE ATCO NOCO NOPT|Lack of test-equipment maintenance|Test Related |OBS-Function|SS - Controls - Electronic Boards|Eth.net items|FMC Test |Incorrect set up/testing
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 08|ATCO NOPT NOCO NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100035400|04/01/2010|priority 2 |Q1|HESS|GOM|RAM Warning on SEM A|NOCO ATCO NOTE|RAM Warning on SEM A|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor related |Equipment Malfunction
ZF|P6000064911|02/11/2011|priority 3 |Q3|Unknown|Unknown|Test procedure  and Config|NOPT ATCO NOCO NOTE|Improved & corrected TST60057930|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|7103233|02/06/2010|priority 3 |Q3|Unknown|Unknown|GA drawing with wrong EC placement|NOCO NOTE ATCO NOPT|DWG contained error  old dwg|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|P6000122574|03/09/2015|priority 3 |Q3|Unknown|Unknown|Too big dim (D5 on drawing)|NOTE NOCO NOPT ATCO|sealing surface diameter out of toleranc|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Accumulator|Vendor related |Specification not followed
ZB|100055600|24/03/2009|priority 2 |Q1|TALOS|GOM|SCM 96 DCV #8 Leaking|NOCO NOPT NOTE ATCO|SCM 96 DCV #8 Leaking|Test Related |OBS-Leakage (Fluid)|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|Vendor related |Equipment Malfunction
ZF|P6000058949|21/02/2011|priority 3 |Q3|Unknown|Unknown|Serrated washers on bolts|ATCO NOCO NOTE|ECN change  part assy after old rev|Design |Material Master Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZE|100051991|11/01/2016|priority 3 |Q3|Unknown|Unknown|WEL Customer Request Improvement|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Customer Requested
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|Rosa 307 communication problems|NOPT NOTE NOCO|Unknown|FMC Other Defect |Unknown|FKS Quality system issues|Quality Management System|FMC Other causes/damage |Unknown
Q1|100005667|20/07/2000|priority 3 |Q1|Unknown|Unknown|SCM HP change over valve leak  well X2-H|NOPT NOCO NOTI ATCO|No fault found at FMCKS|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Åsgard A|Initial/Direct product problem|Leakage
ZF|100049392|01/03/2013|priority 2 |Q3|Unknown|Unknown|DWG for SCM not released in SAP|NOTE NOCO ATCO|DWG not released in SAP|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|SCM11 connector damaged|NOTE ATCO NOCO|Duplicate|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Other causes/damage |QN Cancelled
ZB|P6000079433|28/03/2014|priority 3 |Q1|Unknown|Unknown|Victor Bravo claim #12 SCM|ATCO NOTE NOCO|Fault is CPI DHI card. Rejected warranty|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000024191|01/04/2013|priority 1 |Q3|Unknown|Unknown|FILTRO SEM ORING|NOCO NOPT ATCO NOTE|Filtro sem o-ring|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Intercompany|FMC Kongsberg
Q3|7104033|Unknown|priority 3 |Q3|Unknown|Unknown|SCM # 05 El.rack A an B|NOCO NOTI ATCO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q3|7101401|17/10/2000|priority Unknown|Q3|Unknown|Unknown|Crosstalk comms. interference (offshore)|ATCO NOTI NOCO NOPT|Marlim Manifold crosstalk|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|Customer goods receipt|Initial/Direct product problem|Function
Q1|7103233|08/01/2003|priority 3 |Q1|Unknown|Unknown|SCM TN0 HPE4 SCM-01P comm. failures|NOPT NOTE ATCO NOCO|Unknown|103-Electrical|Modems/Communications|Defect locations - offshore/field|FPSO Terra Nova|Initial/Direct product problem|Function
ZE|P6000109984|17/06/2014|priority 3 |Q3|Unknown|Unknown|oc not fit in outer can|NOTE NOCO ATCO|GWI102  7.3.1 not followed on OC rev B|Unknown|Unknown|SS - Controls -SCM el/opt components|El. / Opt. Connector|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P7000039672|15/05/2014|priority 3 |Q3|Unknown|Unknown|SCM colapsado durante teste Hiperbárico|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Lack of Training
ZF|100035118|26/10/2007|priority 2 |Q3|CHINGUETTI PHASE II|Unknown|(SS) UNABLE TO POWER UP DOWN HOLE GAUGE|NOPT NOCO NOTE|programme error|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Manufacturing related |Programme Error
ZF|P6000104112|21/10/2018|priority 4 |Q3|Unknown|Unknown|Concession to deviate from procedure|ATCO NOTE NOPT NOCO|Unknown|TEST |Test Omitted|Object Types to Eng Matl CLASS|scm_mkIII|FMC Test |Tooling
ZF|P6000121268|13/07/2015|priority 4 |Q3|Unknown|Unknown|In SCM RIT stage O-ring found damage|NOPT ATCO NOCO NOTE|O-Ring damage|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q3|7104075|26/04/2000|priority Unknown|Q3|Unknown|Unknown|Over voltage alarm and no PT reading|NOPT NOCO NOTI ATCO|SIO card was not reset|103-Electrical|Printed Circuit Board|Ext. loc. - KOS Houston|Work Shop|Initial/Direct product problem|Function
ZF|100037427|20/06/2005|priority 2 |Q3|TOTAL|WEST AFRICA|Received SCM with defects|NOCO ATCO NOPT NOTE|Unknown|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZF|100048038|04/10/2006|priority 2 |Q3|Unknown|Unknown|AI 151 card has to be updated|NOTE NOCO ATCO NOPT|Bad workmanship|Design |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM MAN/SIV 05|ATCO NOTE NOCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000039672|20/05/2015|priority 1 |Q3|Unknown|Unknown|Bistable Relay#1 SEM 65A & SEM 65B|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Intercompany|FMC Kongsberg
ZF|P6000138867|04/10/2016|priority 3 |Q3|Unknown|Unknown|SCM exposed with 1100 Bar on HP 1|ATCO NOTE NOCO|SCM HP supply exposed to 1100bar|TEST |Damaged During Testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000001843|30/01/2011|priority 2 |Q3|Unknown|Unknown|Falha no Flowmeter durante In House Test|NOPT NOTE NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|19/05/2014|priority 1 |Q3|Unknown|Unknown|Outercan não monta|NOPT ATCO NOCO NOTE|101545 - KRISTIANSANDS SKRUEFABRIKK &|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Final Inspection Error
ZE|100069556|04/05/2015|priority 3 |Q3|Unknown|Unknown|SCM 09P Bladder RCA|NOTE NOCO ATCO NOPT|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000076121|19/09/2011|priority 3 |Q3|CNOOC|Unknown|Wrong wiring on SCM|NOCO NOTE NOPT|Wrong marking by Opr caused wiring error|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|3787102|31/10/2006|priority 4 |Q1|STATOIL|NORTH SEA|Cont. Mod. delivered without KX + Hyd Co|NOPT NOCO NOTE ATCO|Lack of information on procedures|Change/Deviation Request |Part substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Improper Packaging & Storage
ZF|7101463|03/03/2005|priority 3 |Q3|MOBIL EG|Unknown|part number discrepency on ARF|NOPT NOCO ATCO NOTE|Documentation of p/n|Design |User documentation/procedures|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Do Not Use
ZF|P7000001843|19/01/2011|priority 1 |Q3|Unknown|Unknown|Falta de comunicação SEM B|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000062454|06/04/2011|priority 2 |Q3|DAEWOO|Unknown|(SS) SCM LP DCVs Leaking|NOTE ATCO NOPT NOCO|Testing issues|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000073687|13/06/2012|priority 3 |Q3|FRADE B.V.FRADE PH II|Unknown|HC 2 and HC6 coupler damaged|NOCO ATCO NOPT NOTE|Damaged female couplers due to SCM TS|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Assy |Damaged during assembly
ZF|100005667|13/03/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOTE NOPT ATCO NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000104116|24/10/2014|priority 3 |Q3|Unknown|Unknown|Cannot assemble lifting handle|NOPT NOTE NOCO|Part not according to specification|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 6 RCA Actions_2 from RPT10033107|NOPT NOCO NOTE ATCO|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of Resources
ZF|100018600|01/10/2003|priority 2 |Q3|PETROBRAS|Unknown|SCM not according to dwg|NOPT NOTE NOCO ATCO|Error in drawings and BOM|Assembly / Test related |Documentation - general|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related|Design Specification/Drawing error
Q3|7104670|18/10/2000|priority 3 |Q3|Unknown|Unknown|Comms errors  FSM tied into SCM  (D-1H)|ATCO NOCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Heidrun TLP|Initial/Direct product problem|Function
ZF|P6000108984|28/11/2013|priority 3 |Q3|Unknown|Unknown|To short threads in outercan|NOCO NOTE NOPT ATCO|Interface with EC adapter verified OK|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |No Non-Compliance
ZB|100049000|22/05/2009|priority 2 |Q1|Unknown|Unknown|DHFC SCM 06 RAM Warning|NOCO NOTE|Defective RAM chip|Damage |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZB|100066325|07/10/2013|priority 1 |Q1|Unknown|Unknown|Statfjord Claim Defect in SCM 610|NOCO NOTE ATCO|MRM600 factory default conf.not changed|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000055605|28/03/2018|priority 3 |Q3|Unknown|Unknown|SCM not communicating with MPFM|NOPT OSNO OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000020444|24/08/2011|priority 1 |Q3|Unknown|Unknown|DCV Não Conforme|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZB|100050519|26/02/2015|priority 3 |Q1|Unknown|Unknown|SCM# failure after reworks|NOTE NOCO ATCO|outside warranty period|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
Q3|100005667|17/10/2000|priority 4 |Q3|STATOIL|NORTH SEA|SCM upgrades after removal of outer can|NOCO ATCO NOTI NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZF|100025661|12/07/2006|priority 3 |Q3|SHELL|GOM|DHI NOT CONNECTING|NOPT NOCO NOTE ATCO|DHI NOT CONNECTING|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P7000024191|22/02/2013|priority 1 |Q3|Unknown|Unknown|DCV não conforme.|NOPT ATCO NOCO NOTE|Oceaneering Rotator - PO 47573794|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Missing Parts
ZF|P6000100953|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOTE NOPT NOCO|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
Q3|100005667|13/04/2000|priority 1 |Q3|Unknown|Unknown|Åsg SCM 59  no sensor comms with SEMA|NOCO NOTI NOPT ATCO|No fault found in KOS workshop|280-ETU Software|WOCS software|Defect locations - offshore/field|Transocean Searcher|Initial/Direct product problem|Function
ZD|P6000149536|12/12/2017|priority 1 |Q2|Unknown|Unknown|Marking issue|NOCO ATCO NOTE NOPT|Unknown|Marking |Marking content error|Object Types to Eng Matl CLASS|scm_assy|Marking |Operator
Q3|7102969|20/12/2000|priority 3 |Q3|Unknown|Unknown|Refurbishment/overhaul of valves|NOTI NOCO ATCO NOPT|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|Customer goods receipt|Initial/Direct product problem|Leakage
ZF|100017278|10/06/2005|priority 4 |Q3|STATOIL|NORTH SEA|PT20 sensor show 200 bar > actual press.|NOCO NOTE|Wrong offset value in conf. parametres|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|P6000055198|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|29/10/2014|priority 1 |Q3|Unknown|Unknown|Marcação do transformador incorreta|NOPT NOTE NOCO ATCO|Unknown|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOPT NOTE ATCO NOCO|Dial caliper coupler measurements|Machining Related |OBS-Angle error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100037130|22/11/2018|priority 3 |Q3|Unknown|Unknown|Water ingress in SCM (hyperbaric tank)|NOPT NOTE NOCO ATCO|Testprocedure not followed.|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|P7000039672|20/08/2013|priority 1 |Q3|Unknown|Unknown|Check Valve out of Acceptable Criteria|ATCO NOTE NOPT NOCO|1242 - HTS maskinteknikk as|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Final Inspection Error
Q3|7106268|19/10/2001|priority 3 |Q3|Unknown|Unknown|HXT - X2 pressurised to 520 bar|NOCO NOTI NOPT ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Ext. Loc. - Luanda (Angola)|Work Shop|Initial/Direct product problem|Documentation
ZD|P6000080678|15/01/2016|priority 4 |Q2|Unknown|Unknown|Persephone  SCM  Missing item|NOTE ATCO NOPT NOCO|Unknown|Procurement |Part Not Protected As Per DBI|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100026567|24/10/2003|priority 2 |Q3|STATOIL|NORTH SEA|Failure on SCM#2 (see ref. notification)|NOCO NOPT ATCO NOTE|Broken wire connection.|Assembly / Test related |Function|Subsea Control Module (SCM) Electrical|Hydraulic flow meters|FMC Assembly/Test related|Assembly/Test error
ZF|P6000102687|05/11/2018|priority 2 |Q3|Unknown|Unknown|Concession to deviate from procedure|NOCO NOTE NOPT ATCO|Unknown|Change/Deviation Request |Process substitution request|Object Types to Eng Matl CLASS|scm_mkIIE|Projects Related|Customer Error
ZF|100046112|10/02/2006|priority 3 |Q3|WOODSIDE|Unknown|HP PT's WERE CROSS CONNECTED|NOTE NOPT ATCO NOCO|human error in wiring|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000024900|02/08/2012|priority 1 |Q3|Unknown|Unknown|SRT BC10-34 (Leitura tensão)|NOCO ATCO NOTE NOPT|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 23|ATCO NOPT NOCO NOTE|Investigate Coupler Rotation-BPAT SCM 23|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|P6000122626|22/03/2016|priority 3 |Q3|Unknown|Unknown|EC 3&4 wiring swapped|ATCO NOPT NOTE NOCO|In-house test procedure updated|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100020278|10/11/2011|priority 1 |Q3|Unknown|Unknown|DBI for Chemplex 750 to be alternative|NOTE NOCO ATCO|DBI for Chemplex 750 to be alternative|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZE|P6000028371|22/12/2010|priority 2 |Q3|SHELL|GOM|No reading from WLD|NOTE ATCO NOCO|Two technicians required  outercan assy.|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Outer Can|Variance|Enhance Process
ZF|P7000024191|30/08/2012|priority 1 |Q3|Unknown|Unknown|PT 1A com desvio de leitura|ATCO NOTE NOCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Engineering related |Continuous Improvement
ZF|P6000068924|01/03/2012|priority 1 |Q3|TOTAL|Unknown|Outercan missing holes.|NOTE NOCO ATCO|Outercan produced acc to DWG|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |QN Cancelled
ZF|P1000018406|02/03/2010|priority 3 |Q3|BP|GOM|No p/n marking ID in drawing|NOTE ATCO NOPT NOCO|No p/n marking ID in drawing|Marking |No Marking|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|100035013|27/02/2006|priority 3 |Q3|SHELL|Unknown|Failing communication with CAM200|ATCO NOPT NOTE NOCO|Defective components  U202 & L203|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Component error
ZF|P6000064911|01/06/2015|priority 3 |Q3|Unknown|Unknown|Too short screws|NOPT NOTE ATCO NOCO|Variance of trafo-foot thickness|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Engineering Error
Q2|7102643|Unknown|priority Unknown|Q2|Unknown|Unknown|Refurbishment  Bytting av Trykktandusere|NOTE NOCO ATCO NOPT|Unknown|103-Electrical|RCM Electronics|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
ZB|100020278|13/04/2011|priority 3 |Q1|EXXONMOBIL|Unknown|Warranty claim Megi Sea # 32|NOTE NOCO ATCO|Error in handling|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Control Valve|Intercompany|FMC Houston
Q2|7101172|Unknown|priority 3 |Q2|Unknown|Unknown|GFS SCM 07  Bytting av solenoider|NOPT NOCO ATCO NOTE|Unknown|102-Hydraulic|Hydraulic Control Valves|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Material
Q3|7102643|19/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|Silicone oil leak from SCM compensator|NOTI ATCO NOPT NOCO|Badder hose clamp was not tight|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|NOCO ATCO DLFL|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P7000039672|01/12/2016|priority 1 |Q3|Unknown|Unknown|Top Plate não Monta na Outer Can|ATCO NOPT NOCO NOTE|Unknown|Assembly |Misalignment / Interface Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #5 Wiring|NOPT NOCO NOTE ATCO|BPTH SKOFLO SCM SN #5 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100037966|20/01/2009|priority 1 |Q3|BP|Unknown|B18 SCM  - SEM A communication problems|NOCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Test |Missed operation
ZF|100006609|15/04/2011|priority 2 |Q3|Unknown|Unknown|Problemas com as dimensões da hose house|ATCO NOPT NOTE NOCO|Erro no projeto.|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 31 ÅsgB Y-4H PT func. AWV malfunct.|NOPT NOCO ATCO NOTE|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
Q3|7104033|20/01/2000|priority 3 |Q3|STATOIL|NORTH SEA|12 pin el. connectors to be marked|NOPT NOCO ATCO NOTI|Possible to connect wrongly with ROV|101-Mechanical|Outer Can|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Marking
ZF|7103234|11/05/2007|priority 2 |Q3|Unknown|Unknown|Communication missing|NOTE NOCO NOPT|SELF CORRECTED|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Unknown
Q3|7106268|21/02/2000|priority 3 |Q3|Unknown|Unknown|DIV.|NOCO NOTI NOPT ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. adm.|Initial/Direct product problem|Documentation
ZF|P6000028371|14/04/2008|priority 3 |Q3|SHELL|Unknown|EC wire isolation damaged|NOCO NOPT ATCO NOTE|damaged during wire pull through tube|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Assy |Operator Error
ZF|P6000068924|29/05/2012|priority 3 |Q3|TOTAL|Unknown|EC9 mounted wrong way|NOCO NOTE NOPT|Human error while mounting EC to TS|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100048038|04/09/2008|priority 3 |Q3|Unknown|Unknown|wrong text marking on top plate|NOTE NOCO ATCO NOPT|incorrect position of text and text|Marking |Marking content error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P6000064909|21/03/2011|priority 3 |Q3|Unknown|Unknown|slange sklir av på EC`ne|NOPT NOTE ATCO NOCO|Tie wrap not tight enough on hose to EC|FMC Other Defect |Functional|SS - Controls -SCM el/opt components|El. Connector|FMC Engineering related |Specification error
ZB|7102969|30/07/2007|priority 3 |Q1|Unknown|Unknown|Electrical Flying lead stuck on SCM Elec|ATCO NOTE NOCO|Closed for trending/analysis.|Assembly/Test Related |Interface of components issue|Subsea Control Module (SCM) Electrical|ROV el. connectors|FMC Other causes |Do Not Use
ZD|100015314|12/08/2004|priority 2 |Q2|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|Unknown|INCORRECT LABELLING OF TRONIC CONNECTORS|NOCO ATCO NOPT NOTE|Unknown|Marking |Marking Location Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
Q1|7104670|02/10/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM 05 Heid. SEM B frameerror(not inst.)|NOPT NOTE ATCO NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Transocean Prospect|Initial/Direct product problem|Function
ZF|100034629|13/09/2005|priority 3 |Q3|STATOIL|Unknown|PRESSURIZING RETUR LINE ON SMC|NOCO ATCO NOPT NOTE|Difference beetween dwgs and real umb.|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|P6000088604|22/11/2012|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO NOPT|No SCM failure detected in extend. test|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000098616|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000068924|25/10/2011|priority 3 |Q3|Unknown|Unknown|Wiring fault on Trafo 4|NOPT NOCO NOTE|Wires switched during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Operator Error
ZF|7104075|06/06/2006|priority 3 |Q3|SHELL|GOM|INTERNAL PT FAIL IR TEST|NOTE ATCO NOCO NOPT|INTERNAL PT FAIL IR TEST|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZE|7101937|12/11/2004|priority Unknown|Q3|LUFENG|Unknown|Pre-charge kit for SCM not mobilized|NOCO NOTE NOPT ATCO|Unknown|Unknown|Unknown|Other Subsea Control|Miscellaneous Subsea Control|Administration Related Cause|Documentation Error
ZF|P7000016420|01/08/2011|priority 1 |Q3|Unknown|Unknown|Dano em área de vedação de Adapter Plate|NOTE NOCO NOPT ATCO|Problema na área de vedação|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Tooling
Q3|3812476|08/11/1999|priority 2 |Q3|Unknown|Unknown|SCM HP hyd leak when testing offshore|ATCO NOCO NOTI NOPT|Leaking CVs/CVs were contaminated/dirty|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Transocean Prospect|Root cause Other|Customer-Customer error
ZF|P6000031350|15/05/2009|priority 3 |Q3|Unknown|Unknown|Filling and drain-ports switched places|NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000000897|07/06/2010|priority 1 |Q3|Unknown|Unknown|Center tube damaged SCM SN:05|NOCO NOPT ATCO NOTE|Center Tube damaged|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Damaged during assembly
ZF|P7000000897|02/03/2012|priority 1 |Q3|Unknown|Unknown|Incorrect instrumentation|NOPT NOTE ATCO NOCO|Inamon - erro na instrumentação|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZF|100035014|22/08/2008|priority 2 |Q3|Unknown|Unknown|IO-card problems Canbus disabled automat|NOPT NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|P7000016420|26/01/2011|priority 1 |Q3|Unknown|Unknown|Revestimento do mecanismo de travamento|ATCO NOCO NOTE NOPT|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000002082|02/10/2018|priority 3 |Q3|PETROBRAS|Unknown|MMR - Damged Screw from Outer Can|ATCO NOTE NOCO|Human error|Assembly |Assembled Incorrectly|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Assy |Operator Error
ZF|P6000080678|12/08/2014|priority 4 |Q3|PLUTO EXPANSION|Unknown|Xena - SCM HFT Procedure|NOCO ATCO NOTE NOPT|Wrong PRD used and missing test equipmen|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of DCVs and strainer|ATCO NOTE NOCO NOPT|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZB|100068622|23/04/2015|priority 2 |Q1|Unknown|Unknown|Issues during SCM testing during DEMOB|ATCO NOCO NOPT NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 8 RCA Actions_2 from RPT10033107|NOTE NOCO NOPT ATCO|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of Resources
ZF|P7000024191|11/05/2012|priority 1 |Q3|Unknown|Unknown|Testado em desacordo com o Procedimento|NOTE ATCO NOPT NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000076121|10/10/2011|priority 3 |Q3|Unknown|Unknown|Wiring fault PT 2 and PT 13|NOPT NOCO NOTE|Wiring fault. Human error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100037426|01/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Error in FAT procedure and GA DWG|NOCO NOTE|Procedure Error|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000083428|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100056918|21/06/2011|priority 3 |Q1|PLUTOPLUTO PRODUCTION 05|Unknown|Warranty Claim WELFAFMC110|NOTI DLFL NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|SCM was full of calcium and rust|NOCO NOPT NOTE ATCO|Cleaning and preservation not performed|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P6000028371|10/07/2008|priority 4 |Q3|SHELL|GOM|Manufacturing documentation to be cont..|NOTE NOCO ATCO NOPT|Unknown|Documentation |Unknown|FKS Quality system issues|Noncompliance to Industrial Standard|Other external causes |Unknown
ZB|100052701|01/06/2010|priority 2 |Q1|STATOIL|NORTH SEA|WARRANTY CLAIM TYR SCM Well B1|NOCO ATCO NOTE|No failure found SCM is healthy|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|7105597|06/10/2010|priority 3 |Q3|Unknown|Unknown|Wrong value on calibration test.|NOCO ATCO NOTE|standardization of return pressure test|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000058949|26/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|NOTE NOCO NOPT ATCO|Engineering error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000068924|31/08/2011|priority 3 |Q3|TOTAL|Unknown|350V på SEM|NOPT NOTE NOCO ATCO|Incorrect voltage to transformers|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100018600|19/11/2015|priority 3 |Q3|Unknown|Unknown|MMR - Outer Can Welding|DLFL NOCO NOPT ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|P6000083428|08/05/2013|priority 1 |Q2|Unknown|Unknown|CERT ISSUE|NOCO ATCO NOTE|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|Intercompany|FMC Kongsberg
ZF|P6000050867|21/10/2010|priority 1 |Q3|PETROBRAS|GOM|Issues with redbook|NOTE NOCO ATCO NOPT|Work done before Service Order Created|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Electrical Components|FMC Engineering related |Procedure error
ZF|P7000000897|30/10/2012|priority 1 |Q3|Unknown|Unknown|IN HOUSE / ASSINATURA DE VÁLVULAS|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Function|SS - Controls -Computer system software|ETU SW|FMC Engineering related |Engineering Error
Q3|7102643|17/10/2000|priority 4 |Q3|Unknown|Unknown|SCM upgrades after removal of outer can|ATCO NOPT NOCO NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
ZB|100025661|04/09/2009|priority 2 |Q1|SHELL|GOM|Leaking Silicon Relief Valve on SCM 54|NOTE NOCO ATCO|Leaking Silicon Relief Valve on SCM 54|FMC Other Defect |Physical|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Other causes/damage |Unknown
ZF|100025661|24/09/2003|priority 3 |Q3|Unknown|Unknown|Incorrect couplers specifyed  SCM 15 k|NOTE ATCO NOPT NOCO|Incorrect couper specifyed|Assembly / Test related |Miscellaneous|Subsea Control Module (SCM) Hydraulic|Hydraulic couplers|FMC Engineering related|Miscellaneous Product Design errors
Q3|7104670|17/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|SIO-kort brent ?|NOCO NOPT NOTI ATCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Bergen workshop|Root cause Assembly/Test|Workshop-Assembly/Test error
Q1|3801623|05/09/2000|priority 3 |Q1|Unknown|Unknown|SCM anodes are in wrong position|NOTI NOPT NOCO|Unknown|101-Mechanical|Outer Can|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Function
ZB|100041493|22/11/2006|priority 1 |Q1|STATOIL|NORTH SEA|Damaged exhaust line on SCM # 16 Norne|NOPT NOCO NOTE ATCO|Wear and tear|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZE|P6000063531|17/01/2019|priority 2 |Q3|Unknown|Unknown|SEM  SEM's damaged by P6000067816 at EC4|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100051269|24/05/2007|priority 3 |Q3|STATOIL|NORTH SEA|ALD sensor not working on SEM A.|NOCO NOTE NOPT ATCO|Error in SEM A  ref. SN 300123729|Assembly/Test Related |Function|SS - Controls - Sensors|Leak Detector|FMC Other causes |QN Cancelled
ZF|100020562|19/10/2004|priority 2 |Q3|Unknown|Unknown|Transaqua found in SCM silicone oil|NOCO NOTE ATCO NOPT|Marginal adapter and test plate design.|Assembly / Test related |Leakage (hydraulic  air  nitrogen etc.)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Engineering related |Engineering Error
ZF|P7000008275|08/06/2010|priority 1 |Q3|Unknown|Unknown|Falha de comunicação|NOPT NOCO NOTE|Cancelada por duplicidade|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |QN Cancelled
ZF|100048038|27/03/2007|priority 1 |Q3|AGBAMI|Unknown|Trafo problems on Agbami S/N 23|ATCO NOCO NOPT NOTE|Damage in warehouse handling|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
Q1|7102643|25/01/2002|priority 3 |Q1|STATOIL|NORTH SEA|SCM installation problems on well M3-H|NOTI NOCO ATCO NOPT|Damaged male coupler|102-Hydraulic|Hydraulic Coupler|Defect locations - offshore/field|Viking Poseidon|Initial/Direct product problem|Damages
ZE|100054943|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|ATCO NOCO NOTE NOPT|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Change Seq. of Procedure
ZF|100020562|20/11/2012|priority 1 |Q3|Unknown|Unknown|GA drawing update|NOTE NOPT NOCO ATCO|DWG GA not according to as build|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000079984|03/07/2012|priority 3 |Q3|Unknown|Unknown|Marks on baseplate mounted ECs|NOCO ATCO NOPT NOTE|Wrong angle on connector wing on SCMTS|Damage |Damage during testing|SS - Controls -SCM Test Stand|Other mechanical components|FMC Test |Damaged during testing
ZB|100052701|08/03/2010|priority 3 |Q1|STATOIL|NORTH SEA|Tyrihans Claim 5  7 & 52 HCLD|NOCO NOTE ATCO NOPT|Missing earth strap on HCLD|FMC Other Defect |Functional|Customer Compliant|Noncompliance to Customer Requirement|FMC Assy |Missing Parts
ZF|P6000088626|12/06/2018|priority 1 |Q3|Unknown|Unknown|Concession Request - HFT/mob scope|NOTE NOPT NOCO ATCO|Unknown|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIII|Projects Related|Documentation error
ZF|P6000064911|17/12/2015|priority 1 |Q3|TOTAL|Unknown|Laggan Tormore Silicone in SEM|NOCO ATCO NOTE|Leakage through optical penetrator|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Equipment Malfunction
ZD|P6000102554|17/02/2014|priority 3 |Q2|Unknown|Unknown|SCM/Anadarko/Heidelberg/Error|NOTE ATCO NOCO NOPT|SCM/Anadarko/Heidelberg/Error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|Missing MDB Docs for BPTH SCM23|ATCO NOPT NOCO NOTE|Missing MDB Docs for BPTH SCM23|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|100056261|19/11/2007|priority 3 |Q3|Unknown|Unknown|incorrect thread bush for HC72|NOPT NOTE NOCO ATCO|insufficient interface check|Assembly/Test Related |Interface of components issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
Q1|3812476|08/04/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 2 NORNE D-2H blocked return|NOTE NOCO NOPT|Unknown|102-Hydraulic|Hydraulic Coupler|Defect locations - offshore/field|Norne FPSO|Initial/Direct product problem|Leakage
ZE|P6000108542|08/11/2017|priority 2 |Q3|TULLOW|Unknown|SEM failure  MPFM|ATCO NOTE NOCO|Damaged by external wiring/connection.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Electrical |Specification not followed
ZF|P6000116166|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOCO NOPT ATCO NOTE|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|P6000123495|16/10/2015|priority 2 |Q3|Unknown|Unknown|QA phase B check not performed|ATCO NOTE NOCO|Phase B inspection was performed|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000069056|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|7102969|19/01/2007|priority 3 |Q1|EXXONMOBIL|Unknown|Bad Pig Valve position indicator sensor.|NOCO NOTE ATCO NOPT|Unknown|Assembly/Test Related |Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Engineering related |Lack of Training
ZF|7103233|11/05/2007|priority 2 |Q3|Unknown|Unknown|Sensor has drifted|NOTE NOCO NOPT|this will be logged as a SN|FMC Other Defect |Functional|SS - Compl. & W.Over - XT - General|Pressure & Temperature Transducers|FMC Other causes/damage |QN Cancelled
ZF|P6000028371|06/12/2007|priority 3 |Q3|SHELL|GOM|Cross wired PT 53 and PT 54|NOCO NOPT ATCO NOTE|wiring error|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000020444|02/08/2011|priority 1 |Q3|Unknown|Unknown|Skiped step procedure|NOTE NOPT NOCO ATCO|CWDM missing|Test Related |OBS-Test Omitted|SS - Controls - Electronic Boards|Eth.net items|FMC Test |Tooling
ZF|P6000029772|23/09/2008|priority 2 |Q3|ENGIE|NORTH SEA|Batch number missing|NOCO NOTE NOPT|change to batch management on screws|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|7101401|26/10/2015|priority Unknown|Q3|Unknown|Unknown|MMR - Outer Can Vacuum Tubing damaged|NOTE NOCO ATCO|Unknown|Welding related |Material Issued Damaged|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Fabrication Shop Personnel |Improper Handling
ZF|100037130|19/07/2005|priority 1 |Q3|Unknown|Unknown|Upgrade of proc. for mob of  SCM onshore|ATCO NOCO NOTE NOPT|Final doc did not specify topping of SCM|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|NO TEST REQUIREMENT  FOR CRITAL FUNCTION|NOCO ATCO NOPT NOTE|HFT Missing Testing Requirements|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100020562|02/06/2006|priority 3 |Q3|Unknown|Unknown|Faulty OTF board|NOCO ATCO NOPT NOTE|Faulty OTF board|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZF|P7000039672|23/01/2014|priority 4 |Q3|Unknown|Unknown|Falha na comunicação com a DHI|ATCO NOCO NOPT NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Intercompany|FMC Kongsberg
ZD|100035014|26/09/2007|priority 2 |Q2|Unknown|Unknown|Loss of Comm with the subsea SEMs|NOCO NOTE ATCO|Same case as QN200084493|Documentation |Incorrect user documentation (customer)|FKS Quality system issues|Quality Management System|FMC Other causes |QN Cancelled
ZB|7101172|17/11/2005|priority 3 |Q1|STATOIL|NORTH SEA|Not able to open BSV after vent test|NOCO ATCO NOTE NOPT|Wrong type of O-ring for that environm.|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|100035118|18/05/2005|priority 3 |Q3|PETRONAS|Unknown| ERROR WITH DHI when grounded|NOPT NOTE NOCO ATCO|Error in the DHI card.|Assembly/Test Related |Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Component error
ZF|P6000122626|03/12/2015|priority 3 |Q3|Unknown|Unknown|Wrong position on several DCV's|ATCO NOTE NOPT NOCO|Incorrect assembly by operator|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100029149|10/12/2003|priority Unknown|Q3|TOTAL|WEST AFRICA|RAGS BETWEEN SCM AND TEST STAND|NOTE NOCO ATCO NOPT|Unknown|Assembly / Test related |Workmanship - general|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Operation/maintenance related |Operation error
ZF|P7000039672|04/09/2014|priority 1 |Q3|Unknown|Unknown|Interferência no plug do filtro SCM 43|NOPT ATCO NOTE NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Specification not followed
ZF|P6000084242|03/01/2012|priority 3 |Q3|Unknown|Unknown|207 bar on return line|NOCO NOTE NOPT ATCO|Hydraulic return blocked on SCMTS|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Operator Error
ZD|7103234|29/04/2016|priority 3 |Q2|Unknown|Unknown|SCM Shipped Pre-Charged (Terra Nova)|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZB|P6000108542|13/04/2016|priority 2 |Q1|Unknown|Unknown|Tullow Jubilee FFD SCM 09 hydr leakage|ATCO NOTE NOCO|Leakage hydraulic valves|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Material error
ZB|P7000001621|21/11/2013|priority 1 |Q1|PETROBRAS|Unknown|RTA MEQS/2013/0055A|NOPT NOTI OSTS OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOCO NOTE NOPT|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|P6000120925|27/07/2015|priority 3 |Q3|Unknown|Unknown|Short circuit on EC1|NOCO ATCO NOPT NOTE|See follow-up closing  cause not found|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100018082|11/01/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOTE NOPT ATCO NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|SCM11 connector damaged|ATCO NOCO NOTE|Unknown|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Other causes/damage |QN Cancelled
Q1|7102643|08/08/2000|priority 3 |Q1|Unknown|Unknown|Minor leaks from SCM before installation|NOTI NOPT NOCO ATCO|Damage caused by handling|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|Viking Poseidon|Initial/Direct product problem|Leakage
ZF|P7000001621|01/03/2011|priority 1 |Q3|Unknown|Unknown|AUSÊNCIA DE PINO|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Test |Incorrect set up/testing
ZF|P7000001843|04/09/2017|priority 3 |Q3|PETROBRAS|Unknown|MMR - SCM does not reach vacuum|NOCO NOTE ATCO|Unknown|Assembly |Assembled Incorrectly|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Assy |Operator Error
ZF|P7000024191|23/07/2012|priority 1 |Q3|Unknown|Unknown|SRT SCM GLOBAL SN 03|NOCO NOTE NOPT ATCO|Lab test box with problem.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000024900|24/09/2012|priority 1 |Q3|Unknown|Unknown|Vazamento de nitrogênio no acumulador|NOTE NOCO NOPT ATCO|Erro instrumentação inamom|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Accumulator|Vendor related |Assembly error
ZF|P7000024191|30/10/2012|priority 1 |Q3|Unknown|Unknown|SRT - GLOBAL #11 CAN BUS AND SERIAL LINE|ATCO NOCO NOPT NOTE|Lab test box with problem.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100020562|22/05/2012|priority 3 |Q3|BP|GOM|BP Thunderhorse 5 O-Ring Groove on Base|NOPT ATCO NOCO NOTE|BP Thunderhorse 5 O-Ring Groove on Base|Coating/Plating |Coating defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZD|100038200|19/09/2011|priority 3 |Q2|SHELL|Unknown|Outer Can sandblasting|ATCO NOCO NOPT NOTE|Outer Can Sandblasting|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|3812476|24/02/2015|priority 1 |Q3|Unknown|Unknown|Norne SCM #17  Leaking KX-coupler in lin|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|7101044|02/10/2018|priority 3 |Q3|Unknown|Unknown|Customer not notified for FAT/FI|NOCO NOTE ATCO|Unknown|Documentation Requirement |Other- Specify in comments|SS - Controls - Topside Products|Subsea Power & Communication Unit (SPCU)|Documentation Requirement |Process step missing
ZF|7104033|02/07/2013|priority 3 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOTE ATCO NOPT NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZB|7102969|19/01/2007|priority 3 |Q1|Unknown|Unknown|ROV bucket rust.|ATCO NOPT NOCO NOTE|Inadequate protection from corrosion|Damage |Damage from corrosion|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|Vendor audit related|Unknown
ZF|100037428|29/01/2008|priority 3 |Q3|TOTAL|WEST AFRICA|missing batch numbers|NOTE NOCO NOPT|change to batch management|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |No Non-Compliance
Q1|7103234|19/11/2002|priority 3 |Q1|Unknown|Unknown|SCM TN04I LP Supp. Flowm. O-ring crushed|NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|FPSO Terra Nova|Root cause Vendor|Assembly/Fabrication/Test error
Q3|7100320|Unknown|priority 3 |Q3|PETROBRAS|Unknown|Upgrading of Hercules SCM 17|NOPT NOTI ATCO NOCO|Wrong materials|102-Hydraulic|Hydraulic Control Valves|Defect locations - offshore/field|Campos Basin|Initial/Direct product problem|Material
Q3|7102969|07/12/2001|priority 3 |Q3|EXXONMOBIL|Unknown|SCM needs refurbishment|NOPT NOCO ATCO NOTI|X-tree was accidentaly dropped|100-SCM/RCM|Subsea Control Module|Unknown|Unknown|Root cause Other|Customer-Customer error
ZB|100056443|08/12/2018|priority 3 |Q1|Unknown|Unknown|No power from DHI card SEM B|OSNO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
Q1|7103234|21/02/2003|priority 3 |Q1|OVERALL PROJECT ROLL-UP|Unknown|SCM  suspect leakage past control valves|NOTI NOPT NOCO|Full test done at FKS  no fault found|100-SCM/RCM|Subsea Control Module|Def. loc. - Testing (not int. SCM)|SUT (Stack-up Test)|Initial/Direct product problem|Leakage
Q3|7104075|10/10/2000|priority 3 |Q3|Unknown|Unknown|SCM FAT TPR-11190 Rev.02 requires update|ATCO NOTI NOCO NOPT|Documentation update required|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Documentation
Q3|7103479|28/08/2001|priority 3 |Q3|Unknown|Unknown|Hydrocarbons in function lines & AI-card|NOCO NOTI ATCO NOPT|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Initial/Direct product problem|Leakage
ZF|P6000055198|22/08/2012|priority 2 |Q3|SHELL|Unknown|Failure of SCM Locking Mechanism|NOTE NOCO ATCO|Transport Damage|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Dunfermline
ZF|P6000088751|22/02/2013|priority 1 |Q3|Unknown|Unknown|Replace damaged ribbon-cables|NOCO NOPT ATCO NOTE|Ribbon cable issue  ref QN 200303504|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Material not delivered to plant|NOTE NOCO|Unknown|FMC Other Defect |Functional|MP-FMC Quality System Issues|Measuring  Analysis & Improvement|FMC Other causes/damage |Planning error
ZF|7102969|26/04/2005|priority 3 |Q3|MOBIL EG|Unknown|solinoid valve failure|NOCO NOTE NOPT ATCO|Solinoid valve leaking hydraulic fluid|Assembly/Test Related |Leakage (hydraulic  air  nitrogen etc.)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|P6000042968|09/10/2009|priority 1 |Q3|Unknown|Unknown|Wrong clock freqency on TIFcards|NOCO NOPT NOTE|Vendor requested setting update|Change/Deviation Request |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Incorrect set up
ZF|P7000039672|07/08/2013|priority 1 |Q3|Unknown|Unknown|Outer can não monta|NOTE NOPT ATCO NOCO|101545 - KRISTIANSANDS SKRUEFABRIKK &|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Final Inspection Error
ZF|P7000024191|02/02/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #15 Can Bus $ Serial Line|NOPT NOCO NOTE ATCO|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000088614|08/05/2017|priority 3 |Q3|Unknown|Unknown|ESRS 610 not working properly|ATCO NOPT NOCO NOTE|No fault found  scrap to be safe.|TEST |Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZB|100048038|07/02/2008|priority 2 |Q1|Unknown|Unknown|No communication with DH sensors SEM B|ATCO NOTE NOCO NOPT|No communication with DH sensors SEM B|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|DHI PCBs|Vendor related |Equipment Malfunction
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #18 Wiring|ATCO NOPT NOTE NOCO|BPTH SKOFLO SCM SN #18 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|ATCO NOPT NOTE NOCO|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000098616|15/11/2013|priority 3 |Q3|Unknown|Unknown|Accumulator pressure dropped|NOTE ATCO NOPT NOCO|Pressure drop on accumulator after hyper|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Other causes/damage |Cause not found
ZB|7101172|04/12/2008|priority 4 |Q1|STATOIL|NORTH SEA|I-4H SEMA communication problems|NOTE NOCO NOPT|Updated existing QN 200048719|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |QN Cancelled
ZE|P6000080678|28/12/2015|priority 4 |Q3|Unknown|Unknown|(CDM) Persehone/SCM MKII/Missing item|NOTE ATCO NOCO|Missing component of SCM|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100030542|11/10/2005|priority Unknown|Q3|CNR|Unknown|Flushing with Castrol Transaqua HT|ATCO NOPT NOTE NOCO|Procedure not followed.|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|100006609|07/03/2012|priority 2 |Q1|PETROBRAS|Unknown|RTA MEQS/2012/0024A|NOCO NOPT ATCO NOTE|Interferência entre equipamentos|Design |Specification Error|Subsea Control Module (SCM) Mech w/MB|Other SCM mechanical|FMC Engineering related |Engineering Error
ZF|P6000083428|10/09/2012|priority 3 |Q3|Unknown|Unknown|HC72 to be replaced with blind coupler|ATCO NOPT NOTE NOCO|BOM needs update. Wrong PN on HC72|Change/Deviation Request |Part substitution request|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Specification error
ZE|P6000063531|08/02/2016|priority 3 |Q3|STATOIL|NORTH SEA|Vigdis VEPIII rebuild Leakage|NOPT NOTE NOCO ATCO|Correction fullfilled of supplier|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Variance|Change Seq. of Procedure
ZF|P6000042308|22/02/2010|priority 3 |Q3|TULLOW|WEST AFRICA|Silicone Relief Valve Failure|ATCO NOTE NOCO NOPT|Silicone Relief Valve Failure|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|Intercompany|FMC Kongsberg
ZF|P7000016420|15/06/2011|priority 1 |Q3|Unknown|Unknown|Wiring failure|NOCO NOTE ATCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000043714|10/03/2009|priority 2 |Q3|PETROBRAS|GOM|Failure of SCM to function at Tree EFAT|ATCO NOCO NOPT NOTE|Failure of SCM During Tree FAT|Internal Project Issues Prior To FAT|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Equipment Malfunction
ZF|P6000068912|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000001621|30/04/2010|priority 1 |Q3|Unknown|Unknown|Retirada de parafuso de protection ring|ATCO NOCO NOTE NOPT|Corrosão na rosca|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
Q1|7103233|11/03/2002|priority 3 |Q1|Unknown|Unknown|SCM 01/03P  SCSSV leak into HP line|NOTI NOPT NOCO|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - offshore/field|FPSO Terra Nova|Initial/Direct product problem|Function
ZB|P6000042970|04/01/2010|priority 3 |Q1|TOTAL|WEST AFRICA|Punch List SCM MAN/SIV 04|NOPT NOCO NOTE|Missed operation/procedure not approved|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|DHI FAIL TO CONNECT ON SEM B|NOPT NOCO ATCO NOTE|DHI NOT CONNECTING|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Component error
ZB|P6000088604|04/08/2015|priority 1 |Q1|Unknown|Unknown|SMART TOOL  SPCU AND SCM PRODUCT CONFIG|ATCO NOCO NOTE NOPT|SMART TOOL LOWER VERSION USED|Test Related |OBS-Function|MP-Customer Complaint|Noncompliance to Customer Requirement|FMC Test |Incorrect set up/testing
ZF|P6000123496|24/09/2015|priority 3 |Q3|Unknown|Unknown|Missing test in HW-procedure|ATCO NOCO NOTE|Two tests missing in TST60113250|Test Related |OBS-Test Omitted|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Missed operation
ZF|P6000063531|23/03/2011|priority 2 |Q3|STATOIL|NORTH SEA|SCM fault on external sensors|NOPT NOCO NOTE ATCO|Follow-up in QN200207958 & QN200207982|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P6000108469|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extended test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000042968|17/01/2011|priority 3 |Q3|Unknown|Unknown|Incorrect wiring procedures|ATCO NOCO NOTE NOPT|Mismatch between wiring procedures|Documentation |Procedure / Process Error|SS - Controls -SCM el/opt components|El. Connector|FMC Engineering related |Procedure error
ZF|P6000104111|11/08/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000000229|16/11/2015|priority 1 |Q3|CHEVRON|Unknown|MMR - Loss of Material on Extension Rod|NOTE ATCO NOCO|Lack of grind request after welding|Lack of grind request after welding|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Assy |Missing Operation
Q3|100025735|14/11/2002|priority Unknown|Q3|Unknown|Unknown|Replace of bolts|ATCO NOCO NOPT NOTI|Unknown|100-SCM/RCM|Subsea Control Module|Defect locations - onshore|KOS Kbg. SCM-Workshop - Other|Root cause Engineering|Material fault
Q3|7103233|08/01/2002|priority 3 |Q3|SUNCOR CPI|Unknown|SCM 04 LP/HP hydraulic oil leak offshore|NOTI NOPT ATCO NOCO|Hydrogen embrittlement/corrosion|100-SCM/RCM|Subsea Control Module|Ext. Loc. - St.Johns (Canada)|Goods Receipt|Initial/Direct product problem|Material
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|HFT STEP CAN NOT BE EXECUTED|NOTE ATCO NOCO NOPT|Simulator Not Available|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZF|100048038|10/05/2007|priority 3 |Q3|CHEVRON|WEST AFRICA|Water inside SCM after hyperbaric test|NOCO ATCO NOTE NOPT|Workshop error   drain plug loose|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000043714|07/06/2010|priority 2 |Q3|Unknown|Unknown|Missing parameter Roxar Transparent Aux|NOCO NOPT NOTE|QN Cancelled|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P7000024191|12/09/2012|priority 1 |Q3|Unknown|Unknown|CAN BUS  SERIAL LINE 2|NOPT ATCO NOCO NOTE|Lab test box with problem.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000105542|14/08/2015|priority 1 |Q3|Unknown|Unknown|Severe damage on EC7 identified|ATCO NOPT NOTE NOCO|Dropped metallic cap in EC|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|Missing MDB Docs for BPTH SCM22|NOPT NOCO NOTE ATCO|Missing MDB Docs for BPTH SCM22|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZD|7102969|03/12/2014|priority 3 |Q2|Unknown|Unknown|Verification of EC repair|NOCO ATCO NOPT NOTE|Unknown|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZB|7102643|19/03/2010|priority 3 |Q1|STATOIL|NORTH SEA|SCM 26  Åsg X-3H hyd lock HC21/22|NOCO NOTE NOPT|SCM not modified for Midgard HXT.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|3812476|27/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|Identified defect rectifier bridge|ATCO NOCO NOTE|Unknown|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
Q3|7104033|28/02/2000|priority 2 |Q3|Unknown|Unknown|SCM outer can  wrongly marked with S/N|NOPT NOCO NOTI|Bergen were not informed on marking|101-Mechanical|Outer Can|Defect locations - onshore|KOS Bergen workshop|Initial/Direct product problem|Marking
ZF|P7000024900|04/09/2013|priority 1 |Q3|Unknown|Unknown|Scratches on the base plate|NOPT NOCO ATCO NOTE|Unknown|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Assy |Damaged during assembly
ZF|P6000080343|22/06/2012|priority 3 |Q3|Unknown|Unknown|CV17 signal is switched SEM B|ATCO NOCO NOPT NOTE|Wiring error. Operator error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100020278|02/10/2011|priority 2 |Q3|EXXONMOBIL|Unknown|GR not performed according to process|ATCO NOTE NOCO|Unknown|Documentation |Procedure / Process Error|FKS Quality system issues|Quality Management System|FMC Materials/Stores related |Operator Error
ZB|P6000043122|01/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM SSS 02|NOTE NOCO ATCO NOPT|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|140-141-004|10/04/2014|priority 1 |Q3|Unknown|Unknown|Placa ARI 150 fora de padrão ROII #8 MMR|NOTE ATCO NOCO NOPT|MMR Rio|Damage |Wear & Tear|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Maintenance
ZF|P7000024900|22/10/2013|priority 1 |Q3|Unknown|Unknown|Concession request|NOPT NOTE ATCO NOCO|Unknown|Change/Deviation Request |Process substitution request|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Planning error
ZF|3812476|13/02/2008|priority 4 |Q3|STATOIL|NORTH SEA|Cleaning of SCM in workshop during  Mob|NOCO NOPT NOTE ATCO|Lack of cleaning of SCM in workshop|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor audit related|Unknown
ZD|P6000042969|01/11/2010|priority 2 |Q2|TOTAL|WEST AFRICA|HC 51 is leaking oil|NOCO NOPT NOTE ATCO|Leaking coupler from vendor|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Equipment Malfunction
ZF|P7000039672|03/12/2013|priority 1 |Q3|Unknown|Unknown|Vazamento no manifold block PS#21|ATCO NOTE NOPT NOCO||BOSCH REXROTH LTDA.|Assembly Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Cause not found
ZF|100020562|24/02/2010|priority 3 |Q3|BP|GOM|BPTH SKOFLO Drive to Stem Command|ATCO NOTE NOPT NOCO|BPTH SKOFLO Drive to Stem Command|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Tooling
ZF|100036232|05/06/2013|priority 3 |Q3|Unknown|Unknown|Correction of BOM and DWG|NOCO NOTE ATCO|All docs updated  CM-500000319171|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P7000000897|26/10/2010|priority 1 |Q3|Unknown|Unknown|Test reading fail|NOPT ATCO NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|7102643|12/02/2013|priority 1 |Q1|Unknown|Unknown|GC 227 defect AI card (Statoil Åsgard)|ATCO NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Electrical |Revision Error
ZF|P6000120925|27/04/2015|priority 3 |Q3|Unknown|Unknown|PDO0 and PDO1 test was missing page 53|NOTE NOPT NOCO|Test coverage is correct as is|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|3811810|04/12/2014|priority 3 |Q3|Unknown|Unknown|PN 3810872 not available in SAP|NOCO NOTE ATCO|Not transferred from Procim|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100052701|25/02/2009|priority 3 |Q3|Unknown|Unknown|CPU init. fails at Poweron  OK & Reset|NOCO NOPT ATCO NOTE|Error to be confirmed in QN200124450|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Unknown
ZE|P7000039672|15/05/2014|priority 1 |Q3|Unknown|Unknown|RCA CDM - SCM colapsado (Hiperbárico)|NOPT ATCO NOTE NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Capture Mistake
ZF|P6000103208|29/11/2013|priority 3 |Q3|Unknown|Unknown|Wrong wiring of SCM|NOCO NOPT NOTE ATCO|Not wired according to wiring list|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZB|100046387|05/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|Guarantee claim 157 - Com fail. Sem Sy A|NOPT NOCO NOTE ATCO|Com fail|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P6000101955|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|13/03/2014|priority 1 |Q3|Unknown|Unknown|Trafo sem marcação de alinhamento|NOCO ATCO NOPT NOTE|Unknown|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|7103233|21/10/2010|priority 2 |Q3|SUNCOR|Unknown|SCM returned to FMCK on MMT|NOTE NOCO ATCO NOPT|Goods Receiving Inspection error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZD|P6000122574|09/10/2017|priority 3 |Q2|Unknown|Unknown|FNCR: SCM RT/ NG SCM CLASH|NOPT ATCO NOTE NOCO|Anodes protruding out from OD.|Design |Specification Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL NOCO ATCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P7000001621|06/06/2014|priority 1 |Q3|PETROBRAS|Unknown|MMR - screw with wrong lenght|ATCO NOTE NOCO|No qty enougth of original PN @Warehouse|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Planning error
ZF|P7000024191|17/12/2012|priority 1 |Q3|Unknown|Unknown|SRT - GLOBAL #13 CAN BUS AND SERIAL LINE|NOTE NOPT ATCO NOCO|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|Missing sign offs|ATCO NOCO NOTE NOPT|Missing sign offs|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Documentation error
ZF|100005667|20/02/2013|priority 3 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOCO ATCO NOTE NOPT|Lack of CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000077638|13/08/2014|priority 4 |Q3|Unknown|Unknown|Missing O-ring P/N: 200006913|NOPT NOTE ATCO NOCO|O-ring missing  not supplied|FMC Other Defect |Part Lost|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Missing Parts
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|Unknown|Punch List SCM MAN/SIV 01|NOTE NOCO NOPT|New SW downloaded  QN cancelled|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Other causes/damage |QN Cancelled
ZD|P6000076121|21/11/2011|priority 3 |Q2|CNOOC|Unknown|Possible chips inside the HP-Config Plug|ATCO NOCO NOTE NOPT|Contaminaton concern.CV sent for check.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Clarification
ZF|P6000088751|09/09/2016|priority 3 |Q3|Unknown|Unknown|Water or hydr. fluid in SCM after hyperb|ATCO NOCO NOTE NOPT|Fitting / oring caused leak in hyperbari|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|ATCO DLFL NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZB|P6000088604|13/08/2015|priority 1 |Q1|Unknown|Unknown|XT09 SCM HP RETURN LINE TRANSMITTER NCR|ATCO NOTE NOPT NOCO|Unknown|Test Related |OBS-Function|Customer Compliant|Noncompliance to Customer Requirement|FMC Test |Incorrect set up/testing
ZF|P6000043714|03/03/2009|priority 2 |Q3|PETROBRAS|GOM|Failure of SCM During Tree FAT|NOTE NOCO NOPT ATCO|Failure of SCM During Tree FAT|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P7000039672|17/08/2015|priority 1 |Q3|Unknown|Unknown|PT does not fit on Manifold Block|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Final Inspection Error
ZF|P6000105542|24/10/2013|priority 3 |Q3|Unknown|Unknown|HC53 has to much internal leakage|NOCO ATCO NOPT NOTE|Too high internal leakage on DCV|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000104111|11/04/2016|priority 4 |Q3|Unknown|Unknown|SRT - Value above requrement|NOPT NOTE ATCO NOCO|The actual values for Node ID with name|Test Related |OBS-Function|SS - Controls -SCM Test Stand|Other el/opt components|FMC Test |Incorrect set up/testing
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|HFT STEP CAN NOT BE EXECUTED|NOTE ATCO NOPT NOCO|no Cable Length Simulator defined|Assembly/Test Related |Missed Operation-Assy/Test|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Missing Operation
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|Unknown|08-MEGI-013: RAM Warning Error|NOCO NOTE|Error Message|Test Related |Unknown|Subsea Control Module (SCM) Electrical|Other PCBs|FMC Other causes/damage |Cause not found
Q1|100006609|05/02/2003|priority 1 |Q1|PETROBRAS|Unknown|El. can filled with silicone oil|ATCO NOPT NOTI NOCO|Unknown|103-Electrical|SEM El.Rack|Unknown|Unknown|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|7102643|22/11/2013|priority 2 |Q3|Unknown|Unknown|Poor condition of SCM from KOS2 to KOS1|NOCO ATCO NOTE|Incorrect and missing parts on SCM.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Operation
ZF|P7000001621|11/04/2014|priority 1 |Q3|Unknown|Unknown|MMR - Parafusos e stab de ret. cisalhado|NOCO ATCO NOPT NOTE|Impacto lateral no pino guia.|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Service Related:|Damaged during installation
ZF|100025661|30/04/2012|priority 3 |Q3|Unknown|Unknown|Corrections to TST10001485 Rev A|NOCO ATCO NOTE|Corrections to TST10001485 Rev A|Design |Procedure Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Procedure error
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|SCM11 connector damaged|ATCO NOCO NOTE|Unknown|Damage |Damage during assembly|SS - Controls - Connectors|Electrical/Optical|FMC Other causes/damage |Unknown
ZF|P6000063531|13/04/2015|priority 2 |Q3|STATOIL|NORTH SEA|Vigdis baseplate check valve issue.|ATCO NOCO NOTE|Possible assembly error|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE NOPT NOCO ATCO|Wrong type of screw material in BOM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZB|P6000105542|10/09/2015|priority 2 |Q1|Unknown|Unknown|Oseberg Delta 2 Claim 280-023 SCM 20|ATCO NOCO NOTE|Leaking DCV|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000065886|07/04/2011|priority 3 |Q3|ENI|NORTH SEA|Wiring error|NOTE NOPT ATCO NOCO|Occasional human failure|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100048038|03/12/2008|priority 2 |Q1|AGBAMI|Unknown|SCM #13 SEM A CPU151 RAM WARNING|ATCO NOCO NOTE NOPT|SCM #13 SEM A CPU151 RAM WARNING|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor related |Equipment Malfunction
ZF|P6000105710|21/01/2014|priority 3 |Q3|Unknown|Unknown|Missing log files|NOPT NOCO ATCO NOTE|Missing routines/check list in workshop|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100035014|28/05/2015|priority Unknown|Q3|Unknown|Unknown|Deviation from mobilization scope and pr|NOCO NOTE NOPT ATCO|Customer request to deviate from procedu|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000024191|10/07/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|NOPT ATCO NOTE NOCO|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
Q3|7104075|02/04/2001|priority Unknown|Q3|Unknown|Unknown|SCM EC connector installed incorectly|ATCO NOCO NOPT NOTI|Unknown|202-Electrical/Sensor equipment|Electrical Pin Connetors|Ext. loc. - KOS Houston|Goods Receipt|Root cause Assembly/Test|Workshop-Assembly/Test error
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|FMC Other causes/damage |QN Cancelled
ZF|P6000104114|19/08/2017|priority 3 |Q3|Unknown|Unknown|Leakage on SRM with SN 2|NOTE NOPT ATCO NOCO|Leakage on SRM with SN 2|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Machine Shop Equipment |Machine Malfunction
ZF|7103233|21/08/2017|priority 3 |Q3|Unknown|Unknown|SCM wrong name plate after refurbishment|NOCO NOTE ATCO|Unknown|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000104112|11/04/2016|priority 4 |Q3|Unknown|Unknown|SRT - Value above requrement|NOPT ATCO NOCO NOTE|value above requirement|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZF|P6000064909|03/03/2015|priority 2 |Q3|Unknown|Unknown|Cust Conc: No MOB carried out|NOPT ATCO NOCO NOTE|Unknown|Project|Project Requested Unfinished shipment|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |Planning error
ZB|100035013|11/10/2010|priority 2 |Q1|SHELL|Unknown|Ormen Lange Claim 046 SEM A|NOCO ATCO NOTE|Incorrect assembly Fibreoptic penetrator|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|P6000108542|24/09/2014|priority 2 |Q3|Unknown|Unknown|SCM #1 fails on CIMV|NOCO ATCO NOTE|SCM #1 fails on CIMV|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Chemical Injection Valve|FMC Other causes/damage |Cause not found
ZF|100038200|24/06/2008|priority 3 |Q3|Unknown|Unknown|DH2 and DH3 gauge values swapped|ATCO NOPT NOTE NOCO|DH2 and DH3 gauge values swapped|Design |Specification Error|SS - Controls - Test and Transportation|ETU / Smart Tool HW|Vendor related |Design Error
ZE|100020278|02/05/2011|priority 1 |Q3|Unknown|Unknown|Protection Skirt Orientation|NOCO ATCO NOPT NOTE|Orientation on part not acc to GA DWG|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Customer Requested
ZD|7104075|03/10/2012|priority 3 |Q2|Unknown|Unknown|SCM EC Bolt Holes out of tolerance|ATCO NOTE NOPT NOCO|SCM EC Bolt Holes out of tolerance|Raw Material |OBS-Dimensional|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZD|P6000080343|02/08/2012|priority 3 |Q2|Unknown|Unknown|Hydr fluid out of silicone chk valve|NOCO ATCO NOPT NOTE|Hydr fluid out of silicone chk valve|Raw Material |OBS-Defects in material|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P7000001621|23/12/2014|priority 2 |Q3|Unknown|Unknown|PORO|NOPT ATCO NOCO NOTE||||Welding related |Cladding Surface NDE Defect|SS - Template & Manifold - Manifold|Manifold|FMC Weld Shop Personnel |Operator error
ZF|P6000108984|04/11/2013|priority 3 |Q3|Unknown|Unknown|Error in  BOM-P6000108986|NOCO NOPT ATCO NOTE|Process not followed by engineering|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|100066325|18/05/2015|priority 2 |Q1|Unknown|Unknown|SCM Hydraulic leakage (Statoil SSP MKI)|ATCO NOPT NOTE NOCO|Pinhole in bladder due to particles|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000058949|26/08/2010|priority 2 |Q3|STATOIL|NORTH SEA|Hydraulic leakage inside the module|NOCO NOTE ATCO NOPT|Strength for screw too close pre-tension|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|P6000105542|02/02/2016|priority 2 |Q1|Unknown|Unknown|Gullfaks GSO Claim 293 DefectLVDT SUBSEA|NOTE ATCO NOCO|Equipment installed  need investigation|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|100055600|06/03/2010|priority 2 |Q1|HELIX ESGHOUSTON STOCKING SCM MK II (15K)|Unknown|LP supply PT bad output|NOTE NOCO ATCO|LP supply PT bad output|Test Related |OBS-Component Error|Subsea Control Module (SCM) Electrical|Pressure transducers|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000105542|07/01/2015|priority 3 |Q3|Unknown|Unknown|NCR to Statoil - SCM manifold block|NOTE NOCO|Unknown|Welding related |Structural Dimensional Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000065528|26/09/2011|priority 2 |Q3|Unknown|Unknown|Burned PT/TT simulator`s|ATCO NOCO NOPT NOTE|Operator error and procedure error|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100052231|15/11/2010|priority 3 |Q3|CHEVRON|GOM|Issue with HFT60015785|NOPT ATCO NOTE NOCO|Issue with HFT60015785|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO NOPT NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100001156|20/11/2014|priority 2 |Q3|STATOIL|NORTH SEA|High Voltage applied to SCM|ATCO NOTE NOCO NOPT|Operator used wrong supply voltage|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|P6000042968|11/03/2010|priority 3 |Q3|Unknown|Unknown|New config due to software upgrade.|NOTE ATCO NOCO|Too many objects added to the config.|Unknown|Unknown|SS - Controls - Topside Products|N/A SW|Causes for Improvement|Documentation
ZF|P6000108469|20/02/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extended test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|03/07/2015|priority 1 |Q3|Unknown|Unknown|DHI sensor doesn't communicate|NOTE NOPT NOCO ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Operator Error
ZF|P6000104111|07/05/2016|priority 1 |Q3|Unknown|Unknown|Wrong CPU mac adr (SRT)|ATCO NOCO NOTE|Wrong CPU mac adr|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100050383|09/05/2007|priority 4 |Q3|STATOIL|NORTH SEA|Replace control valves on TORDIS|NOCO ATCO NOPT NOTE|Unknown|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Engineering related |Engineering Error
ZF|100029062|28/04/2006|priority 2 |Q3|TOTAL|Unknown|SCM PSM ERROR|ATCO NOCO NOTE NOPT|documentation correction - procedure|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Logist.-Handling/Packing/Shipping error
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|SCM was full of calcium and rust|ATCO NOTE NOCO NOPT|Unknown|Assembly/Test Related |Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|100037966|03/01/2006|priority 3 |Q3|BP|Unknown|SCM input voltage outside limits|ATCO NOCO NOTE NOPT|incorrect wiring to SFS-card  input P2.2|Assembly/Test Related |Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Assy |Manufacturing Engineer Erorr
ZF|100048038|21/04/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|Pressure re-test of AGB SCM S/N 08.|NOTE NOPT ATCO NOCO|Unknown|Design |Procedure Error|FKS Quality system issues|Management Responsibility|FMC Assy |Missing Operation
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|SCM 34 ÅsgB X-1H PT Choke close malfunc.|NOPT NOTE NOCO ATCO|Unknown|103-Electrical|Pressure Transducer|Defect locations - offshore/field|Åsgard B|Initial/Direct product problem|Function
Q3|7105130|Unknown|priority 3 |Q3|Unknown|Unknown|SCM M 02|NOPT NOCO ATCO NOTI|||101-Mechanical|1641 Subsea Control Module (SCM)|Defect locations - onshore|KOS Kbg. SCM-Montasje|Initial/Direct product problem|Cleanliness
ZF|P6000079433|04/01/2016|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|NOTE NOCO NOPT ATCO|Lack of test equipment|Obsolescence Issue:&|Not Available|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Other causes/damage |Cause not found
ZB|100056261|31/08/2009|priority 2 |Q1|MURPHY|WEST AFRICA|SEM Common Alarm|NOCO NOTE ATCO|SEM Common Alarm|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |Cause not found
ZF|P7000001621|13/12/2010|priority 1 |Q3|Unknown|Unknown|Fechamento da Outer  Can Hércules SN16|ATCO NOPT NOTE NOCO|Interferencia na montagem da Outercan|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Engineering Error
ZF|100058509|03/08/2011|priority 2 |Q3|Unknown|Unknown|Trending Issue with LLOG ETU|NOPT NOTE NOCO|Cancelled duplicate as SN 300280430|Test Related |OBS-Function|SS - Controls - Topside Products|Other Topside Products|FMC Other causes/damage |QN Cancelled
ZF|100017278|20/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|F&D09 Mob. is not performed  on SCM|NOTE ATCO NOCO NOPT|No time for a mobilization of  the SCM|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|P6000066700|16/09/2011|priority 1 |Q3|Unknown|Unknown|Missing HC in SCM OKONO|ATCO NOTE NOCO NOPT|Missing coupler in HC71  SCM Okono|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZB|100020278|01/12/2009|priority 2 |Q1|EXXONMOBIL|Unknown|SCM - invalid readings|ATCO NOCO NOTE|SCM - invalid readings|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|I/O PCBs|FMC Test |Damaged during testing
ZF|P6000029772|31/05/2013|priority 3 |Q3|Unknown|Unknown|SRM not ready for mobilization|NOPT NOTE NOCO ATCO|Unknown|Documentation |Incorrect user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|P6000068924|25/10/2011|priority 1 |Q3|TOTAL|Unknown|Wrong use of miniseal|NOCO NOTE ATCO|Procedures need update with miniseal use|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Electrical Wire|FMC Engineering related |Procedure error
ZF|P6000068912|04/07/2012|priority 2 |Q3|Unknown|Unknown|Unstable reading from PT09 (summary QN)|NOCO NOPT NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P6000074156|10/12/2015|priority 3 |Q3|Unknown|Unknown|2810X35ZZ1 SCM not properly stored WCS|NOCO ATCO NOTE|Stored Outside for Extended period|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Improper handling
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|NOPT NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P6000108984|12/02/2015|priority 4 |Q3|Unknown|Unknown|(CDM-SN)SEM B PDHG FAILURE DS-02|NOTE ATCO NOCO|SEM B PDHG FAILURE DS-02|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000105542|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100048038|08/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|The cable idents is missing|NOTE NOPT ATCO NOCO|Unknown|Marking |No Marking|Common/Misc - General|Cable|FMC Assy |Missing Operation
ZF|P6000126219|05/01/2018|priority 3 |Q3|Unknown|Unknown|Internal leakage from nitrogen accumulat|NOPT ATCO NOCO NOTE|Fitting not tighten with correct torque.|TEST |Leak|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Assy |Operator Error
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOCO NOPT NOTE|Followed up in QN 200456167|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZF|100018531|02/08/2011|priority 1 |Q3|Unknown|Unknown|DHI 108 not communicating|ATCO NOTE NOPT NOCO|Documentation incompatibility|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Engineering related |Procedure error
ZF|P6000069056|15/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|Wiring on CVLP10 & CVLP11 crossed|NOPT NOCO NOTE ATCO|Mixup in wiring|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100052231|22/09/2014|priority 3 |Q3|Unknown|Unknown|For lange skruer til  plastikk klammer|NOPT ATCO NOTE NOCO|Old error in BOM/DWG corrected|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P6000088604|21/08/2012|priority 3 |Q3|Unknown|Unknown|Get parts for extra earthing rail|NOTE ATCO NOCO NOPT|Extra parts for earth rail.|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|SEM Bracket|Projects Related|Material error
ZF|P7000024900|20/06/2012|priority 1 |Q3|Unknown|Unknown|Base plate com revestimento não conforme|ATCO NOCO NOPT NOTE|||Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Materials/Stores related |Improper Packaging & Storage
ZD|P6000088604|05/04/2013|priority 1 |Q2|Unknown|Unknown|Chevron Wheatstone SCM#1 Wiring issue|ATCO NOTE NOCO NOPT| SCM#1 Wiring issue|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|P7000016420|27/10/2011|priority 1 |Q3|Unknown|Unknown|Control Valve does not work properly|ATCO NOCO NOTE NOPT|DCV - control valve ROTATOR|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P7000020444|14/09/2011|priority 1 |Q3|Unknown|Unknown|Teste hiperbárico ( Marlim 02)|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100017278|05/09/2014|priority 1 |Q3|Unknown|Unknown|Small notch in outercan.|ATCO NOCO NOTE|Source of damage not known|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZB|P6000063531|28/04/2017|priority 2 |Q1|Unknown|Unknown|Vigdis FD028 SCM  failure test ALD|NOCO ATCO NOTE NOPT|Most likely defect connector in SCM|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIII|Electrical |Other- Specify in comments
ZF|P7000016420|06/08/2015|priority 1 |Q3|Unknown|Unknown|MMR - DHI 205|NOTE NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|P6000079984|03/07/2012|priority 3 |Q3|Unknown|Unknown|Marks on baseplate mounted ECs|NOTE NOCO NOPT ATCO|Follow up in ZD QN:200279919|Damage |Damage during testing|SS - Controls -SCM Test Stand|Other mechanical components|FMC Test |Damaged during testing
ZF|P7000016420|13/03/2012|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 14|NOPT ATCO NOTE NOCO|lab test box com fio solto|Kongsberg - CPU without sofware|Vendor issue due to other QN|Não realização de teste|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Equipment Malfunction
ZF|P6000028371|27/10/2010|priority 2 |Q3|Unknown|Unknown|Missing data in flushing procedure.Sekv1|NOPT ATCO NOTE NOCO|Flushing procedure not specified|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100048038|05/05/2012|priority 3 |Q3|CHEVRON|WEST AFRICA|AGBAMI SCM 42 DH SIMULATORS  ISSUES|NOTE NOPT NOCO ATCO|AGBAMI SCM 42 DH SIMULATORS  ISSUES|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100035013|19/11/2014|priority 3 |Q3|Unknown|Unknown|Damaged threads in outer can|NOCO NOTE ATCO|Damaged thread during MMR.|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Damage from Wear and Tear
ZF|100026328|26/03/2013|priority 2 |Q3|Unknown|Unknown|Ovalização da protection ring  Viola 02.|NOPT ATCO NOCO NOTE|MMR SCM|Damage |Damage during transport|SS - Controls -SCM  hyd/mech components|Other mechanical components|Other external causes |Customer Error/responsibility
ZF|P7000039672|18/11/2013|priority 1 |Q3|Unknown|Unknown|HP Return Flowmeter não está lendo|NOPT NOTE ATCO NOCO|2618  Flow Technology Inc.|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZF|100005667|13/11/2013|priority 2 |Q3|Unknown|Unknown|Missing GA DWG on ÅSG SCM PN 100005667|ATCO NOCO NOPT NOTE|Drawing updated and released|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000093498|13/05/2014|priority 3 |Q3|Unknown|Unknown|Missing connection in wiring list|NOCO NOTE NOPT ATCO|Wiring connection missed in wiring list|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000065528|17/03/2011|priority 2 |Q3|Unknown|Unknown|feil i henhold til sjematikk du600054974|NOPT NOCO ATCO NOTE|Designer error|Documentation |Procedure / Process Error|SS - Controls -SCM el/opt components|SCM Wiring|FMC Engineering related |Engineering Error
ZF|100035013|06/11/2014|priority 3 |Q3|Unknown|Unknown|SEM B can filled with Silicone|NOPT NOTE NOCO ATCO|Leakage on insert optical penetrator|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Equipment Malfunction
ZF|P6000104112|13/10/2014|priority 3 |Q3|Unknown|Unknown|LP-R Flowmeter does not measure low flow|NOPT NOTE ATCO NOCO|Incorrect counting at minumum flow|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZD|P6000109194|24/09/2014|priority 1 |Q2|Unknown|Unknown|QUALITY ISSUE.|NOTE NOCO ATCO|Unknown|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000104111|14/11/2014|priority 3 |Q3|Unknown|Unknown|Wrong  in config|ATCO NOCO NOTE NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|100056443|06/11/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|SCM polluted with water/glycol|ATCO NOPT NOCO NOTE|Oparator error resulted in contamination|Test Related |OBS-Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P7000020444|20/09/2017|priority 3 |Q3|PETROBRAS|Unknown|MMR - PTs' Readings Out of Tolerance|ATCO NOTE NOPT NOCO|Unknown|TEST |Component Error|Object Types to Eng Matl CLASS|scm_mkIII|Test |Improper Set/Up
ZD|P6000104116|07/07/2014|priority 1 |Q2|Unknown|Unknown|Incorrect Revision|NOTE NOCO ATCO|VL SPECIFICATION NOT FOLLOWED|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|SCM 2  Function Line PTs  Angus 4|NOPT NOCO NOTE|SCM 2 Function Line PTs Angus4|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|100031223|07/08/2013|priority 3 |Q3|Unknown|Unknown|DHI Interface test in FAT not performed.|ATCO NOTE NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P7000016420|14/07/2010|priority 2 |Q3|PETROBRAS|Unknown|Danos superficias na área de vedação|ATCO NOTE NOCO NOPT|Unknown|Raw Material |OBS-Defects in material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage during transport
ZF|P7000000897|06/02/2012|priority 1 |Q3|Unknown|Unknown|BASE PLATE ARRANHADA NA ÁREA DO O´RING.|NOPT NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Assy |Damaged during assembly
ZF|100035013|12/08/2015|priority 2 |Q3|SHELL|Unknown|Ormen Lange Leaking Penetrator SEM B|NOPT NOTE NOCO ATCO|Leaking optical penetrator|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Equipment Malfunction
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOPT ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|P6000042968|25/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 17|NOCO ATCO NOPT NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|7104020|16/03/2015|priority 3 |Q2|Unknown|Unknown|Machining discrepancies on ROV bore|NOCO ATCO NOPT NOTE|Unknown|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P7000000897|28/02/2012|priority 1 |Q3|Unknown|Unknown|Outer Can Scratch|NOPT NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Packaging/Handling
ZD|P6000057855|17/02/2010|priority 3 |Q2|Unknown|Unknown|Communication failure SEM|ATCO NOTE NOPT NOCO|improper anchorage of intrconnect wires|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Engineering related |Continuous Improvement
ZB|P6000103208|04/08/2016|priority 2 |Q1|Unknown|Unknown|Julia SCM 05 Various|NOCO NOTE ATCO|Claim rejected|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Houston Subsea
ZF|100049000|23/04/2015|priority 2 |Q3|Unknown|Unknown|Paint Does Not Cover Exterior Weld|NOCO ATCO NOTE NOPT|Paint Does Not Cover Exterior Weld|Coating/Plating |Painting Not Applied|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZE|100035118|27/07/2012|priority 2 |Q3|Unknown|Unknown|(SS)Enfield SCM Bladder|NOCO NOPT NOTE ATCO|Bladder P/N200007430 defect|Unknown|Unknown|Subsea Control Module (SCM) Mech w/MB|Outer can|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000104112|10/04/2015|priority 3 |Q3|Unknown|Unknown|Multiple loose fittings on SCM|NOCO NOTE NOPT ATCO|Missed operation during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZE|P6000123882|08/11/2017|priority 4 |Q3|Unknown|Unknown|Update Top Plate Drawing to include|NOTE NOCO ATCO|Installation Eng. want marking on top.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Marking |Other- Specify in comments
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE ATCO NOPT NOCO|Wrong type of screws in BOM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZE|P6000062990|01/03/2018|priority 3 |Q3|Unknown|Unknown|(E) - SCM SW Verification Process Escape|NOPT OSTS OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000016420|28/02/2011|priority 1 |Q3|Unknown|Unknown|Revestimento não conforme|NOCO ATCO NOPT NOTE|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Cause not found
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOCO ATCO NOTE NOPT|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|100049000|09/09/2009|priority 2 |Q3|BP|GOM|BP Atlantis (DHFC) SCM 04|NOTE ATCO NOPT NOCO|Wrong fluid type|Test Related |OBS-Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZD|P6000109194|23/12/2014|priority 1 |Q2|Unknown|Unknown|REVISION ISSUE.|NOTE ATCO NOCO|VL|Documentation |Missing Certificates / Records|SS - Controls - Test and Transportation|SCM Lifting Tool|Vendor related |Documentation
ZF|P6000084242|15/08/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Rebuild to Copi South Belut from Bawal|NOCO ATCO NOPT NOTE|Requested rebuilt for new project|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000016420|31/05/2011|priority 1 |Q3|Unknown|Unknown|Teste Hiperbárico SCM P-55 SN03|NOCO ATCO NOPT NOTE|Camara Hip.|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Test |Incorrect set up/testing
ZF|P6000064910|01/06/2011|priority 2 |Q3|TOTAL|NORTH SEA|ILT/FLET ->MCM test  comunication error|NOTE NOCO ATCO NOPT|TestCable properties not matching equipm|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000039672|24/02/2016|priority 1 |Q3|Unknown|Unknown|Bilnd nao monta no manifold block|ATCO NOCO NOTE NOPT|||Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Final Inspection Error
ZF|P7000039672|12/01/2018|priority Unknown|Q3|Unknown|Unknown|Falha na leitura PT2 elet. B|NOPT NOCO NOTE ATCO|Unknown|TEST |Function|Object Types to Eng Matl CLASS|tree_assembly|FMC Test |Incorrect set up/testing
ZB|P6000079984|08/01/2014|priority 3 |Q1|Unknown|Unknown|UNAPPROVED REVISION OF FAT PROCEDURE USE|NOPT NOTE ATCO NOCO|UNAPPROVED REVISION OF FAT PROCEDURE USE|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100020562|16/06/2010|priority 1 |Q3|BP|GOM|pod serial # 17 that came off Tree 3...|ATCO NOCO NOTE NOPT|Testing of the SCM|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P6000080678|19/08/2014|priority 1 |Q3|PLUTO EXPANSION|Unknown|Xena - SCM Adapters not supplied|NOCO NOTE ATCO|DBI missing test hoses in BOM|Design |DBI Error|SS - Controls -SCM Test Stand|Hydraulic Hose|FMC Engineering related |DBI error
ZF|P6000069056|29/06/2011|priority 3 |Q3|STATOIL|NORTH SEA|Flushing valve swapped with HC58|ATCO NOTE NOPT NOCO|Incorrect assembeled flushing valves|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000083428|04/09/2013|priority 2 |Q3|Unknown|Unknown|Failure on return check valve|ATCO NOTE NOPT NOCO|Check valve slightly out of tolerance|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZF|P7000016420|12/07/2011|priority 1 |Q3|PETROBRAS|Unknown|Vazamento no acumulador.|NOCO NOPT NOTE ATCO|Erro de instrumentista contratado.|Test Related |OBS-Leakage (gas)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZF|P6000057007|29/09/2010|priority 3 |Q3|LLOG|GOM|Bad AI board readings for SEM A|NOTE NOCO NOPT ATCO|Bad AI board readings for SEM A|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|P6000077638|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000055213|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOPT ATCO NOCO NOTE|Incorrect screw quality used in BOM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000077632|12/12/2014|priority 3 |Q3|Unknown|Unknown|Gas lekage inside SCM after hyperbaric|NOPT NOTE NOCO ATCO|Fittings not tighten properly.|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Assy |Operator Error
ZF|100037966|21/01/2008|priority 2 |Q3|BP|Unknown|High pressure sensor|ATCO NOTE NOPT NOCO|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Assy |Unknown
ZF|P6000042969|06/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|micro controller error|NOCO NOTE ATCO NOPT|No HW err. on CPU board  ref QN200175629|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes/damage |QN Cancelled
ZF|P7000024900|16/01/2012|priority 1 |Q3|SHELL|Unknown|BASE PLATE ARRANHADA NA ÁREA DO O´RING.|ATCO NOPT NOTE NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Assy |Damaged during assembly
ZF|100020562|27/05/2013|priority 1 |Q3|Unknown|Unknown|Missing test equipment calibration|NOCO ATCO NOTE|Continuous Improvement|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000069056|21/08/2012|priority 3 |Q3|Unknown|Unknown|SEM A Loosing communication|ATCO NOTE NOCO NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|Basis 200e SW|FMC Engineering related |Engineering Error
ZF|P6000039844|27/01/2009|priority 3 |Q3|SHELL|Unknown|Nitrogen leakage in hyperbaric|ATCO NOCO NOPT NOTE|fitting not tightened enough to seal|Test Related |OBS-Leakage (gas)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P7000024191|27/07/2012|priority 1 |Q3|Unknown|Unknown|SRT GLOBAL 04 LABTEST BOX|NOTE ATCO NOCO NOPT|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZE|P6000126219|03/11/2017|priority 2 |Q3|Unknown|Unknown|SCM  Missing test of new PT during FI|NOCO NOTE ATCO|Changed operator during test.|TEST |Function|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Test |Procedures not Followed
ZE|P6000076121|24/06/2013|priority 2 |Q3|Unknown|Unknown|SCM Mal function|NOPT ATCO NOCO NOTE|SCM mal function|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|100020562|18/08/2014|priority 3 |Q3|Unknown|Unknown|High LP DCV Leakage Rate|NOCO ATCO NOTE NOPT|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Other external causes |Customer Error/responsibility
ZD|P6000093501|14/11/2012|priority 3 |Q2|Unknown|Unknown|VOLTAGE OUT OF CRITERIA|NOCO NOTE ATCO|HFT issue|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000122626|21/06/2016|priority 2 |Q3|Unknown|Unknown|SCM fluid cleanliness verification|NOCO ATCO NOTE NOPT|Unknown|Test Related |OBS-Cleanliness|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |Cause not found
ZB|100050519|04/02/2010|priority 2 |Q1|Unknown|Unknown|Faulty readings on sensors on SCM|NOTE ATCO NOCO|Faulty Readings on sensors|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Manufacturing Engineer Erorr
ZE|100027228|31/08/2016|priority 3 |Q3|Unknown|Unknown|Wrong DHI table in HFT-0000020536|ATCO NOTE NOCO|Procedure updated|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P1000018406|13/11/2012|priority 3 |Q3|Unknown|Unknown|Hydraulic fluid in silicone sample|ATCO NOCO NOTE NOPT|QN will be canceled Duplicate|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000147469|13/12/2017|priority Unknown|Q3|Unknown|Unknown|Unable to get communication with EC7 har|ATCO NOTE NOCO|Unknown|Damage |Damage during assembly|Object Types to Eng Matl CLASS|scm_assy|Assembly |Damaged During Assembly
ZB|100020278|06/03/2009|priority 2 |Q1|EXXONMOBIL|Unknown|09-MEGI-019: Unauthorized choke movement|NOTE NOCO|09-MEGI-019: Unauthorized choke movement|Test Related |OBS-Function|Valves - General|Chokes|FMC Other causes/damage |Cause not found
ZE|P6000039844|12/02/2014|priority 3 |Q3|Unknown|Unknown|Lp adapterplate need adapter for tube.|NOPT ATCO NOCO NOTE|Wrong part used in BOM.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZB|100067526|29/06/2016|priority 2 |Q1|Unknown|Unknown|GFC well M-4H LP1/LP2 does not operate|NOCO NOPT NOTE ATCO|Equipment Subsea- Cause not found|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #16 Wiring|NOCO NOTE ATCO NOPT|BPTH SKOFLO SCM SN #16 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P7000039672|05/05/2015|priority 1 |Q3|Unknown|Unknown|Falta de parafusos do kit p/ Conector|NOTE NOCO ATCO NOPT|Unknown|FMC Other Defect |Part Lost|SS - Controls - Electric Products|Electrical Connector|Vendor related |Specification not followed
ZF|P6000069056|04/09/2012|priority 3 |Q3|Unknown|Unknown|Pressure test: High pressure in LP lines|ATCO NOTE NOCO NOPT|HP pressure in LP lines.Operator error|Test Related |OBS-Wrong Test Procedure Used|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Test |Operator Error
ZF|P6000069820|16/05/2011|priority 3 |Q3|Unknown|Unknown|Wrong testplug on SCM|NOTE NOPT NOCO|Wrong test plug mounted for use inhouse|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIA NA ROSCA DA ADAPTER PLATE|NOCO NOPT NOTE ATCO|Acabamento de rosca não ok|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Operator Error
ZF|P6000068912|05/06/2013|priority 3 |Q3|Unknown|Unknown|Loose bolts on outercan SCM.|NOTE NOCO NOPT|Loose bolts  follow up RCA 200323341|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100035013|26/05/2009|priority 2 |Q3|SHELL|Unknown|Unknown|NOTE NOCO ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls - Topside Products|Filter|Other external causes |Unknown
ZF|P6000105542|16/12/2013|priority 3 |Q3|Unknown|Unknown|Too high leakage|NOCO ATCO NOPT NOTE|Too high and unstable leakage from DCVs|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000083428|10/09/2012|priority 3 |Q3|Unknown|Unknown|HC72 to be replaced with blind coupler|NOPT NOCO NOTE ATCO|Client request  rebuild SCM  remove HPI|Change/Deviation Request |Part substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000039672|20/06/2014|priority 1 |Q3|Unknown|Unknown|Válvula com vazamento no Leakage Test|NOPT NOTE NOCO ATCO|1659 - Oceaneering Rotator AS|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000104112|10/09/2015|priority 3 |Q3|Unknown|Unknown|Change name plate|NOCO NOTE ATCO|New name plates are delivered|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P6000088614|16/09/2014|priority 3 |Q3|Unknown|Unknown|PDO 0 shows 17V when powered OFF on SEMB|NOCO NOTE NOPT ATCO|Penetrator leakage  followup QN200411902|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Vendor related |Assembly error
ZF|P6000079984|30/07/2013|priority 3 |Q3|Unknown|Unknown|ASSY/EXXON (HSE)/Software/ESRS FILE|NOCO NOTE ATCO|ASSY/EXXON (HSE)/Software/ESRS FILE|Test Related |OBS-Function|SS - Controls - Topside Products|N/A SW|Intercompany|FMC Kongsberg
ZF|P6000105542|06/08/2014|priority 2 |Q3|Unknown|Unknown|SCM router cards damaged|ATCO NOCO NOTE|Incorrect XT BOM  insufficient assy doc|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000024191|05/03/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #17 Can Bus & Serial Line|NOTE NOPT ATCO NOCO|Lab Test Box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000016420|03/10/2011|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 08|NOCO NOTE ATCO NOPT|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Test |Incorrect set up/testing
ZF|P6000076121|14/01/2011|priority 2 |Q3|LIU HUA 4-1|Unknown|Production stop HUSKY LIWAN|NOPT NOCO ATCO NOTE|Production stop H.Liwan to Liu Hua SCMs|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|P6000039844|22/08/2018|priority Unknown|Q3|Unknown|Unknown|Missing test equipment / CR request|NOTE NOPT NOCO|Unknown|Electrical |Other- Specify in comments|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Incorrect set up/testing
ZF|P6000116166|04/03/2015|priority 3 |Q3|Unknown|Unknown|Bad connection on EC6 pin 3|NOTE ATCO NOPT NOCO|Followed up in QN 200430835|Test Related |OBS-Function|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Equipment Malfunction
ZF|P6000132097|31/03/2016|priority 3 |Q3|Unknown|Unknown|Too big leakage during SCM leakage test|NOTE NOCO ATCO|Changed out due to obsolence|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |No Non-Compliance
ZF|100052231|01/10/2014|priority 3 |Q3|Unknown|Unknown|Change Thread Bush and move Blind plug|NOTE NOCO ATCO NOPT|Error in BOM and drawing|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000065886|09/02/2011|priority 3 |Q3|Unknown|Unknown|Faulty procedure|NOTE NOCO ATCO NOPT|Test&Flushing procedure faulty|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000016420|03/05/2011|priority 1 |Q3|Unknown|Unknown|Furo desalinhado|ATCO NOTE NOPT NOCO|Furo não estava casando|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Material error
ZB|P6000028371|26/04/2010|priority 3 |Q1|SHELL|GOM|MPFM Abnormal Readings|ATCO NOTE NOCO|MPFM Abnormal Readings|Test Related |OBS-Component Error|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor related |Equipment Malfunction
ZF|P6000079433|09/11/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Possible chips inside the HP-Config Plug|NOTE ATCO NOPT NOCO|Plugs not cleaned by supplier.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZD|7101463|15/06/2010|priority 3 |Q2|EXXONMOBIL|Unknown|Deep scratch in SCM 7 EC sealing surface|NOPT NOTE ATCO NOCO|Deep scratch in SCM 7 EC sealing surface|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZE|P6000073687|28/06/2012|priority 3 |Q3|Unknown|Unknown|Missing info on GA dwg.|NOTE ATCO NOCO|Missing info on GA drawing|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZE|P6000068918|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update MCM HFT - Luanda Workshop|NOCO NOTE|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZB|100036936|26/04/2017|priority 3 |Q1|Unknown|Unknown|LP suply flowmeter failure (SCM URD)|NOTE NOCO ATCO|lowmeter(FM)failure due to contamination|TEST |Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000039672|12/08/2013|priority 1 |Q3|Unknown|Unknown|Vazamento na adapter plate de LP|NOPT ATCO NOCO NOTE|123643 - BOSCH REXROTH LTDA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZF|P6000079984|14/01/2013|priority 3 |Q3|Unknown|Unknown|no gap between Guide Rails and Outercan|NOTE ATCO NOCO|Guide rails slightly out of tol.accepted|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZE|P6000104116|15/10/2014|priority 3 |Q3|Unknown|Unknown|O-ring sealing surface fault|NOTE ATCO NOCO NOPT|DWG updated ref ECN 6180458|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZE|P6000079433|02/01/2012|priority 3 |Q3|Unknown|Unknown|Not able to mount bolt.|NOCO NOTE ATCO|BOM not aligned with ASM instruction|Assembly Related |OBS-imension (tolerance)|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Engineering related |Engineering Error
ZF|P1000018406|18/04/2011|priority 3 |Q3|BP|GOM|Unacceptable part|NOTE NOPT NOCO ATCO|Unacceptable part|Coating/Plating |Coating defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000091085|26/01/2016|priority 3 |Q3|Unknown|Unknown|Discrepancies in SW Release dates & SPC|NOPT ATCO NOCO NOTE|Manual process failed|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000105542|05/11/2013|priority 3 |Q3|Unknown|Unknown|Too high leakage during leakage test|NOTE ATCO NOPT NOCO|DCV leakage followed up in ZD   ZE QN|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100066465|03/08/2011|priority 3 |Q3|Unknown|Unknown|PT/TT 4 not working properly|NOTE ATCO NOPT NOCO|Board overstressed  ref RCA task|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZB|100033987|22/11/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 256|NOCO NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|100036232|16/12/2014|priority 2 |Q1|Unknown|Unknown|Issue with Bergen refurbished SCM|ATCO NOTE NOCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|P7000024191|01/10/2012|priority 2 |Q3|Unknown|Unknown|SRT Global 9 can bus and Serial Line S2|NOPT ATCO NOCO NOTE|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000105542|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000079984|24/04/2013|priority 3 |Q3|Unknown|Unknown|Test Error/Exxon/SCM/DownholeCardIssues|NOTE NOCO NOPT ATCO|Test Error/Exxon/SCM/DownholeCardIssues|Test Related |OBS-Component Error|SS - Controls - Topside Products|Other Topside Products|Intercompany|FMC Kongsberg
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #13 Wiring|NOCO NOPT ATCO NOTE|BPTH SKOFLO SCM SN #13 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000067533|11/01/2011|priority 2 |Q3|Unknown|Unknown|Wrong screws for mounting covhp|NOCO ATCO NOPT NOTE|BOM incorrect.M8 screw instead of M10|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Engineering related |DBI error
ZF|P6000028371|30/11/2010|priority 2 |Q3|SHELL|GOM|Lost measurement on PT24.|NOCO NOTE ATCO NOPT|Accidental operator failure|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Assy |Damaged during assembly
ZB|100035014|23/06/2010|priority 3 |Q1|STATOIL|Unknown|WN990### - SCM Manifold TT Discrepancy|NOPT NOPR NOTE OSTS|SCM card defaulted|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|100035013|03/01/2010|priority 2 |Q3|SHELL|Unknown|Communication failure on SEM|NOCO NOTE|SCM failure  SCM changed|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Projects Related|Material error
ZF|P7000039672|16/07/2015|priority 1 |Q3|Unknown|Unknown|SEM A do SCM com Leitura Divergente|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Intercompany|FMC Kongsberg
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL ATCO NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P6000105542|13/05/2015|priority 2 |Q3|STATOIL|NORTH SEA|Hydraulic leakage manifold block/adapter|NOCO ATCO NOTE|Contamination below o-ring  caused leak|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Operator Error
ZF|P6000104113|23/04/2014|priority 4 |Q3|Unknown|Unknown|CANbus CITV fault|NOPT ATCO NOCO NOTE|Wiring updatet and checked OK|Test Related |OBS-Function|SS - Controls -Instrumentation|Chemical Injection Valve|FMC Test |Missed operation
ZF|100048038|10/04/2009|priority 4 |Q3|CHEVRON|WEST AFRICA|Unable to Hold Pressure|NOPT NOTE NOCO ATCO|Unable To Hold Pressure|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000042308|02/06/2009|priority 3 |Q3|TULLOW|WEST AFRICA|Witness Notification To Customer Missed|ATCO NOPT NOTE NOCO|Witness Notification To Customer Missed|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|P7000024900|11/10/2012|priority 1 |Q3|Unknown|Unknown|SRT - BC-10  #37 Communication Failure|ATCO NOPT NOCO NOTE|Download failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZB|P6000063531|09/10/2017|priority 1 |Q1|Unknown|Unknown|Power supply error|DLFL NOCO NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZD|7100320|02/05/2016|priority 3 |Q2|PETROBRAS|Unknown|MMR - Couplers leakage|DLFL NOPT ATCO NOCO NOTE|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100035013|22/02/2016|priority 3 |Q3|Unknown|Unknown|Incorrect wiring of LP Changeover Valve|NOPT NOCO ATCO NOTE|Operator Error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|Unknown|(SS) MRM Software Version update|NOCO NOTE ATCO|MRM Software Bug Fix|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000116166|28/10/2014|priority 3 |Q3|Unknown|Unknown|3 o-ring on hydraulic fitting is damaged|NOTE NOCO NOPT|Bad O-rings followed up by Common|FMC Other Defect |Physical|Common/Misc - Fittings|Other|FMC Other causes/damage |Cause not found
ZE|P6000088604|19/03/2015|priority 2 |Q3|Unknown|Unknown|(SS) Verification of comm issue of SCM|NOCO ATCO NOTE NOPT|Verification of comm issue of SCM|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P7000016420|09/11/2011|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 10|NOCO ATCO NOTE NOPT|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000104112|30/08/2017|priority 3 |Q3|Unknown|Unknown|SCM ISSUED HAVE SILICON|NOCO ATCO NOTE|SCM ISSUED HAVE SILICON|TEST |Leak|Object Types to Eng Matl CLASS|scm_mkIII|FMC Assy |Operator Error
ZF|100048038|24/10/2014|priority 3 |Q3|Unknown|Unknown|Too high internal leakage Agbami SCM 44|ATCO NOCO NOPT NOTE|Too high internal leakage on DCV 3|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZB|P6000064911|29/07/2014|priority 3 |Q1|TOTAL|NORTH SEA|Laggan Claim 070 - SRM failure|ATCO NOPT NOCO NOTE|Leaking optical penetrator|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|P7000039672|22/05/2017|priority 1 |Q3|Unknown|Unknown|SNR  VARIABLE BELOW EXPECTED VALUE|NOCO ATCO NOPT NOTE|Unknown|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIIE|Intercompany|FMC Kongsberg
ZF|100037965|30/01/2015|priority Unknown|Q3|Unknown|Unknown|inconsistent valve signature|NOTE NOCO ATCO|Wrong flow restrictor in BOM|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P7000039672|05/09/2018|priority 1 |Q3|Unknown|Unknown|ECN  7090703    PN  P7000017838|NOCO NOTE NOPT ATCO|Error-concept/calculation|Design |DBI Error|Object Types to Eng Matl CLASS|kits|FMC Engineering related |ECN Change
ZF|100056443|03/10/2018|priority 3 |Q3|Unknown|Unknown|LD-Delay on Delivery Kongsberg MS30 SCM|OSTS OSNO|Delay in Production|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZF|100055762|13/03/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to company PO|NOPT NOCO NOTE ATCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZB|7103553|13/10/2017|priority 2 |Q1|Unknown|Unknown|MDS Manifold SCM Comms Failure Support|ATCO NOCO NOTE|Specification not clear enough|TEST |Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Software |Other- Specify in comments
ZF|P1000018406|24/06/2011|priority 3 |Q3|Unknown|Unknown|BP DHFC Failed Check Valve|NOTE NOCO ATCO|BP DHFC Failed Check Valve|Test Related |OBS-Function|Valves - General|Check Valves|FMC Test |Damaged during testing
ZF|P7000020444|19/07/2011|priority 1 |Q3|Unknown|Unknown|value does not meet accepted criteria|NOCO ATCO NOPT NOTE|Due to a different set up|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|FMC Test |Operator Error
ZF|P6000104116|28/10/2014|priority 3 |Q3|Unknown|Unknown|O-ring surface too rough|NOCO ATCO NOTE NOPT|Sealing Surface sandblasted  ZD200410470|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZB|P6000102554|03/02/2014|priority 3 |Q1|Unknown|Unknown|Heidelberg - Anadarko Claim SCM 01|NOTE ATCO NOCO|Operator error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Fabrication Shop Personnel |Operator error
ZF|100059660|16/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|Problems receiving flow meter values|ATCO NOTE NOCO NOPT|Adapter plate for Flowmeter design error|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZD|100025661|12/02/2014|priority 3 |Q2|Unknown|Unknown|Damage to outer can’s EC ports|ATCO NOCO NOTE NOPT|Unknown|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|100035013|23/06/2015|priority 2 |Q3|Unknown|Unknown|Silicone inside both SEM A and B|ATCO NOTE NOCO|Optical penetrator leaking|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZE|P6000088751|21/12/2012|priority 2 |Q3|Unknown|Unknown|Update KS200e SW to 610.0|NOCO ATCO NOTE|To Update KS200e SW to 610.0|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZB|3787101|10/03/2017|priority 1 |Q1|Unknown|Unknown|MCM Quality of Internal Wiring|NOTE NOCO NOPT ATCO|Design obsolete and replaced|Electrical |Wiring short|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO NOTE ATCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000081371|17/09/2012|priority 3 |Q3|Unknown|Unknown|Checkvalves doesn't fully enter|ATCO NOTE NOCO NOPT|Bad threads in baseplate (for chk valve)|Machining Related |OBS-Thread Error|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Tooling
ZF|7104670|06/07/2018|priority 3 |Q3|Unknown|Unknown|CIDV 1 failed during Mobilization|ATCO NOPT OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100056261|23/08/2010|priority 3 |Q3|MURPHY|WEST AFRICA|Incomplete databook|NOCO NOTE ATCO NOPT|Engineering Sign offs required|Documentation |Procedure / Process Error|Stage Gate Review|Quality Documentation|FMC Engineering related |Continuous Improvement
ZF|7100320|29/04/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Couplers leakage|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Equipment Malfunction
ZF|100056443|01/09/2009|priority 1 |Q3|EDISON/EDF|NORTH SEA|Contaminated oil in SCM  TFHPU  SCMTS|NOCO ATCO NOPT NOTE|Operator used wrong fluid|Test Related |OBS-Cleanliness|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|100036936|29/09/2010|priority 3 |Q3|Unknown|Unknown|Documentation Norne Sat|NOTE NOCO ATCO|Wrong P/N linked to Procedure|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZE|P6000080678|07/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM) Xena - SCM HFT Procedure|NOPT NOCO NOTE ATCO|HFT Procedure Not Customized for Scope|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOPT NOTE ATCO NOCO|Dial caliper coupler measurements|Machining Related |OBS-Angle error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000067533|07/01/2011|priority 2 |Q3|Unknown|Unknown|missing flushing lines  in the procedure|NOCO NOPT ATCO NOTE|Missing steps in procedure.Human error|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000126219|15/08/2017|priority 3 |Q3|Unknown|Unknown|Megging of EC 2|ATCO NOCO NOTE NOPT|Moisture on components.|Electrical |Functional|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|Electrical |Other- Specify in comments
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|ATCO DLFL NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Engineering related |ECN Change
ZF|P7000039672|03/10/2014|priority 1 |Q3|Unknown|Unknown|protection ring ovalizada|NOTE NOPT ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Damage during transport
ZF|100005667|11/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|Åsg F&D 10 Break up SCM w/Override tool|NOPT NOTE NOCO|Procedure needs updating|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|P7000039672|12/01/2017|priority 1 |Q3|Unknown|Unknown|Falha de leitura no PT 03 da Sem A|NOCO NOTE NOPT ATCO|Unknown|TEST |Function|SS - Controls -SCM  hyd/mech components|Hydraulic Pressure Intensifier|Vendor related |Equipment Malfunction
ZF|3794920|26/05/2016|priority 3 |Q3|Unknown|Unknown|Error on alternative program (EEPROM)|ATCO NOCO NOPT NOTE|EEPRPOM Failure.|Obsolescence Issue:&|End Of life (EOL) (Obsolete)|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Unknown|Unknown
ZE|P6000084242|02/05/2012|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Fault in procedure TST60075261|NOTE NOCO NOPT ATCO|TST proc. fault in flushing LP\HP lines|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000104116|28/10/2014|priority 4 |Q3|Unknown|Unknown|Holes for lifting bolts not aligned|NOTE NOCO NOPT ATCO|Paint and hole aligment error|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZB|P6000105542|12/08/2014|priority 2 |Q1|Unknown|Unknown|GSO Claim 001 SCM Router cards|NOCO ATCO NOTE|Wrong connector installed on XT|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Fabrication Shop Personnel |Operator error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO NOTE ATCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000098616|22/05/2013|priority 1 |Q3|Unknown|Unknown|Bad twisting of wires|ATCO NOCO NOTE|Bad twisting of wires|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Other causes/damage |Planning error
ZF|100037427|27/10/2011|priority 1 |Q3|TOTAL|Unknown|Parts not according to BOM/DBI|NOCO NOPT ATCO NOTE|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P6000031350|20/03/2014|priority 3 |Q3|Unknown|Unknown|Damaged wire|ATCO NOCO NOPT NOTE|Wires pulled out from penetrator RCA TBA|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|P7000039672|01/02/2018|priority Unknown|Q3|Unknown|Unknown|SCM colapsado durante teste Hiperbárico|NOTE NOPT ATCO NOCO|Unknown|TEST |Damaged During Testing|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Test |Damaged during testing
ZF|P7000020444|29/06/2012|priority 1 |Q3|Unknown|Unknown|SRT com desvios|NOTE ATCO NOCO NOPT||Documento não marcado como HP|Assembly Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000058949|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|ATCO NOTE NOCO|Engineering error  5 WHY in QN:200186565|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|ATCO NOCO NOTE|DWG error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZB|140-141-004|06/12/2012|priority 2 |Q1|PETROBRAS|Unknown|RTA MEQS 2012/0016A|NOCO NOTE ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000104114|21/05/2014|priority 4 |Q3|Unknown|Unknown|Update of baseplate on SRM|ATCO NOTE NOCO NOPT|Wrong position of silicone check valve|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Engineering related |DWG Error
ZF|P6000104112|10/04/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000098616|10/09/2013|priority 3 |Q3|Unknown|Unknown|PT5 is showing high value at zero pressu|ATCO NOCO NOPT NOTE|PT value increaseing  follow up200341036|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Other causes/damage |Cause not found
ZF|P6000098616|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|3787102|26/02/2008|priority 4 |Q1|STATOIL|NORTH SEA|Guarantee claim 146 - Leakage  valves|NOPT ATCO NOCO NOTE|Leakage on solenoid valves|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P7000039672|11/01/2016|priority 1 |Q3|Unknown|Unknown|Tygon Hose com diametro maior|NOCO NOPT ATCO NOTE|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Final Inspection Error
ZF|P7000001621|18/11/2011|priority 1 |Q3|Unknown|Unknown|Fechamento da Outer can Hércules #19|NOPT NOTE NOCO ATCO|decorrente do processo de reparo|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Other causes/damage |Cause not found
ZF|P6000065886|23/05/2017|priority 3 |Q3|Unknown|Unknown|CCB Board in SESI burned and shorted|ATCO NOCO NOPT NOTE|short in the CCB board in SESI|TEST |Damaged During Testing|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Test |Damaged during testing
ZF|P6000103208|19/05/2014|priority 4 |Q3|Unknown|Unknown|EC 1 loose screws|NOPT NOTE NOCO ATCO|Screws not torqued as specified|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000050867|05/01/2011|priority 1 |Q3|Unknown|Unknown|TST was not released in TCE|ATCO NOPT NOTE NOCO|TST was not released in TCE|Documentation |Procedure / Process Error|SS - Controls - Electric Products|Electrical Components|FMC Engineering related |Procedure error
ZF|100031193|21/10/2011|priority 1 |Q3|Unknown|Unknown|Mudança de plaqueta de identificação|NOCO NOTE NOPT ATCO|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZB|100034629|04/10/2018|priority 3 |Q1|Unknown|Unknown|Fiber A&B is possibl. switch in SCM(OSB)|NOPR NOPT OSTS NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000028371|08/12/2010|priority 2 |Q3|SHELL|GOM|No reading from WLD|NOCO NOTE ATCO NOPT|WLD wire damage during assy of outercan|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Operator Error
ZF|P6000069056|15/03/2011|priority 3 |Q3|Unknown|Unknown|SCM – return line compensator|ATCO NOPT NOTE NOCO|Water ingress onto hyd.system(NCR)|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZE|P6000074156|29/07/2016|priority 3 |Q3|Unknown|Unknown|HFT60070348 - Final Prep of ESRS600|ATCO NOCO NOTE|Chapter missing in procedure|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|100050519|18/09/2013|priority 1 |Q3|MOHO BILONDO|Unknown|SCM Damaged During Training|ATCO NOTE NOCO|Lack of training/operator error|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Compensator|FMC Test |Operator Error
ZF|100033987|21/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|F&D09 Mob. is not performed  on SCM|NOPT NOCO NOTE ATCO|No time for a mobilization of  the SCM|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|100055762|01/02/2010|priority 2 |Q3|Unknown|Unknown|Test procedure missing information|NOCO NOTE NOPT ATCO|Old procedure  voided and replaced|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZD|P6000122574|29/03/2018|priority 1 |Q2|Unknown|Unknown|Revision Issue|NOCO NOTE ATCO|NVL ENGINEERING ERROR|Marking |No Marking|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Engineering related |Specification error
ZE|P6000088604|19/12/2016|priority 1 |Q3|Unknown|Unknown|Wheatstone SCM  Communication error|ATCO OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100054943|29/09/2008|priority 1 |Q3|WOODSIDE|Unknown|CVLP failes during hyperbaric test|NOCO NOTE ATCO NOPT|workmanship failure|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Lack of Training
ZB|100017997|04/09/2009|priority 2 |Q1|BP|GOM|Ruptured Bladder|NOTE ATCO NOCO NOPT|Damaged Bladder|Damage |Damage during assembly|Subsea Control Module (SCM) Hydraulic|Compensators|Vendor related |Assembly error
ZD|P6000079433|12/06/2013|priority 1 |Q2|Unknown|Unknown|LP return leaking on SCM|NOCO NOTE ATCO|Smart return on SCM faulty -|Procurement |Vendor did not complete required work|SS - Controls - Hydraulic Products|Relief Valve|Intercompany|FMC Kongsberg
ZF|P6000122574|26/09/2017|priority 3 |Q3|Unknown|Unknown|CHECK VALVE/ DRAWING INCONSISTANT|NOTE NOCO ATCO|Installed wrong by Technician|Assembly |Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100036232|16/12/2014|priority 2 |Q3|Unknown|Unknown|Issue with FMC Norway refurbished SCM|NOTE NOCO ATCO|Lack of GA DWG|Workshop technician failure|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |DWG Error
ZB|100018082|10/04/2014|priority 1 |Q1|Unknown|Unknown|Warranty claim 259-Malfunct.SEM B SUBSEA|NOTE NOCO ATCO|Unknown|Obsolescence Issue:&|Not Available|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZE|100020562|27/05/2013|priority 4 |Q3|Unknown|Unknown|Missing test equipment calibration|NOTE ATCO NOCO|Continuous Improvement|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000024191|23/11/2012|priority 1 |Q3|Unknown|Unknown|Coupler de supply(HC 2) vazando - SCM 10|ATCO NOPT NOCO NOTE|Sem evidência da causa|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Other causes/damage |Cause not found
ZF|P6000132097|04/03/2016|priority 3 |Q3|Unknown|Unknown|Too big leakage during SCM leakage test|NOPT NOCO NOTE ATCO|Too high internal leakage on COVHP|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZB|P6000122574|16/08/2017|priority 3 |Q1|Unknown|Unknown|Suncore Terra Nova SCM #3 Kulite PT fail|ATCO NOTE NOCO|PT failure|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIIE|Electrical |Bad part
ZD|100056261|19/05/2008|priority 3 |Q2|Unknown|Unknown|No DBI for part number|ATCO NOTE NOPT NOCO|No DBI for part number|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE ATCO NOCO|BOM incorrect.M6 A4-80 to M6 inconell718|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P6000058949|05/12/2012|priority 3 |Q3|Unknown|Unknown|To high pressure on the DIACS return|ATCO NOCO NOTE|Return hose not properly connected|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|NOCO ATCO NOPT NOTE|Coupler Interface on m.block (spc error)|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Specification error
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|Unknown|(SS) MRM Software Version update|ATCO NOCO NOTE NOPT|MRM Software Bug Fix|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000028371|23/01/2008|priority 3 |Q3|Unknown|Unknown|Replacement of COV and strainer|NOTE NOPT ATCO NOCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZD|P6000028371|05/01/2015|priority 3 |Q2|Unknown|Unknown|Damage EC ports|ATCO NOCO NOPT NOTE|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|100020562|28/10/2009|priority 2 |Q3|BP|GOM|Return Compenstator Test SCM 24|NOCO NOPT ATCO NOTE|Return Compenstator Test SCM 24|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P6000123495|25/04/2016|priority 4 |Q3|Unknown|Unknown|HP Supply aproximately 19bar|ATCO NOTE NOCO|PT has to be replaced|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Engineering related |Engineering Error
ZF|100067526|19/08/2014|priority 2 |Q3|STATOIL|NORTH SEA|MMR Gullfaks 5 Accumulator contamination|NOTE NOCO ATCO|Accumulator contains wrong fluid|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Accumulator|Vendor related |Specification not followed
ZF|P6000074156|15/07/2013|priority 3 |Q3|Unknown|Unknown|Shell West Boreas XT # 4 - SCM|NOPT NOTE ATCO NOCO|SCM Overpressure|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000039672|04/08/2014|priority 1 |Q3|Unknown|Unknown|Oxidação na SEM bracket|NOCO ATCO NOTE NOPT||1553 - AS Koberg|Assembly Related |OBS-Interface issue|Common/Misc - Seals|Non-Metallic|FMC Materials/Stores related |No Non-Compliance
ZF|P6000101955|09/07/2014|priority 3 |Q3|STATOIL|NORTH SEA|3- Silicone leakage on Primary SCM S/N 3|ATCO NOTE NOCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000076121|04/01/2012|priority 1 |Q3|CNOOC|Unknown|(SS) Frequency and Software issue in SCM|NOTE NOPT NOCO ATCO|Frequency and Software issue in SCM|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P7000001621|09/07/2015|priority Unknown|Q3|Unknown|Unknown|MMR - DHI boards do not communicate|NOCO NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZB|100035118|08/01/2016|priority 3 |Q1|Unknown|Unknown|WEL  Test Failure  L1 Escape|NOCO ATCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100056443|23/02/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|Addition of Grounding Power-can|NOCO ATCO NOPT NOTE|Design improvement for safety precaution|Design |Specification Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|100055762|09/10/2010|priority 4 |Q3|STATOIL|NORTH SEA|SCM inter. accumulat.not charged|ATCO NOPT NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|P6000069820|31/10/2013|priority 4 |Q3|Unknown|Unknown|COPI Platform Comms Startup Shutdown|NOTE NOPT ATCO NOCO|Unable to establish communication|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Variance|Capture Mistake
ZD|7104075|16/01/2014|priority 3 |Q2|Unknown|Unknown|Damage EC connectors on outer can|NOTE NOCO ATCO|Unknown|Damage |Damage Due to Handling|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|100059660|09/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|Problems receiving flow meter values|NOTE NOCO NOPT ATCO|BOM and DWG error.Adapter plate design|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZB|100025661|27/04/2010|priority 2 |Q1|SHELL|GOM|Shell Llano 2 Topsides|ATCO NOCO NOTE|Shell Llano 2 Topsides|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Special electronics.|FMC Test |Tooling
ZF|P7000039672|04/11/2014|priority 1 |Q3|Unknown|Unknown|Troca de montagem eletrônica|NOTE NOPT ATCO NOCO|||Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Assy |Operator Error
ZF|100050519|13/05/2013|priority 2 |Q3|TOTAL|Unknown|Down Hole Gauge Loss of communication|NOCO ATCO NOTE|Follow-up in common ZE QN 200369318|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Other causes/damage |Cause not found
ZD|7103233|16/09/2010|priority 1 |Q2|Unknown|Unknown|Lloyds release note missing (IRN)|NOTE ATCO NOCO|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|100038200|18/07/2011|priority 3 |Q3|SHELL|Unknown|EC Seal Surface Welding Issue|NOCO NOTE ATCO NOPT|EC Seal Surface Welding Issue|Damage |Damage during assembly|SS - Controls -SCM  hyd/mech components|Outer Can|Intercompany|FMC Kongsberg
ZF|P7000039672|25/03/2015|priority 1 |Q3|Unknown|Unknown|Ext. Rod com imperfeição superficial|NOCO ATCO NOTE NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Operator Error
ZE|P6000055605|28/03/2016|priority 2 |Q3|Unknown|Unknown|Update TST10051297|NOCO NOTE ATCO|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZB|100036936|02/11/2014|priority 3 |Q1|Unknown|Unknown|Communic.problem-connecting UDF to Norne|ATCO NOTE NOCO NOPT|Human error|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Operator Error
ZF|P6000043714|02/07/2010|priority 2 |Q3|PETROBRAS|GOM|Control fluid in silicone sample|NOTE NOCO NOPT ATCO|Cause for leakage not found|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZD|100049000|15/06/2010|priority 3 |Q2|BP|Unknown|SCM ASSY|NOPT ATCO NOCO NOTE|SCM ASSY|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Damaged during assembly
ZE|7103553|12/10/2017|priority 2 |Q3|SHELL|Unknown|SEM  Wrong communication frequenzy|NOPR OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P1000018406|30/01/2014|priority 3 |Q3|Unknown|Unknown|Damage: BP/DHFC/MQC Sheared Pin|NOPT ATCO NOTE NOCO|MQC Sheared Pin|Design |Procedure Error|SS - Controls -Hydraulic Distribution|MQC|FMC Assy |Missing Operation
ZF|7102643|08/04/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOPT NOCO NOTE ATCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #17 Wiring|NOCO ATCO NOPT NOTE|BPTH SKOFLO SCM SN #17 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P1000018406|27/04/2010|priority 3 |Q3|Unknown|Unknown|MQC Outboard Assembly|NOPT NOCO NOTE ATCO|Warehouse Improper Storage of  MQC|Damage |Damage Due to Handling|SS - Controls - Hydraulic Products|Multi Quick Connector (MQC)|FMC Materials/Stores related |Improper Handling
ZF|P7000000897|03/11/2011|priority 1 |Q3|SHELL|Unknown|Wrong ECs Marking on base plate.|NOTE ATCO NOPT NOCO|USILIDER - BASE PLATE|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Operator Error
ZF|P6000121268|02/02/2015|priority 3 |Q3|Unknown|Unknown|SCM flow restriction error|ATCO NOCO NOTE NOPT|Missing information in procedure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|DLFL NOCO ATCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOTE NOPT NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100049000|16/05/2013|priority 3 |Q3|Unknown|Unknown|Incorrect coating on outer can|NOTE ATCO NOCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|P6000088604|10/04/2013|priority 3 |Q3|Unknown|Unknown|Short-circuit|NOPT NOCO ATCO NOTE|Illegal operation allowed in debug SW|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000055605|15/02/2011|priority 3 |Q3|SHELL|GOM|Do not get vacuum on SCM|ATCO NOTE NOCO NOPT|Tie wrap found in El.Bracket caused leak|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100005667|08/02/2013|priority 3 |Q1|Unknown|Unknown|Leakage from module during MOB for Y-1H|NOTE NOCO|unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Test |Damaged during testing
ZE|P6000116166|19/12/2014|priority 3 |Q3|Unknown|Unknown|Wiring fault CAN-bus|NOCO NOTE|Wrong SESI used  SESI not available.|Unknown|Unknown|SS - Controls -SCM el/opt components|SCM Wiring|Projects Related|Material error
ZF|P7000000897|21/09/2010|priority 1 |Q3|Unknown|Unknown|Revestimento de item - mecanismo de trav|NOCO ATCO NOTE NOPT|Wrong coating|Coating/Plating |Coating not applied|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZE|P6000064909|27/10/2014|priority 2 |Q3|TOTAL|Unknown|SCM HFT amendments|ATCO NOTE NOCO|Continuous improvment|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|NOTE ATCO NOCO NOPT|Design error on DWG|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZB|100018082|12/02/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 225-Mikkel|NOTE NOCO ATCO|Damage to equipment|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZE|P6000088751|17/04/2018|priority 2 |Q3|Unknown|Unknown|CDM -GWF-2 SCM - PT Sensor Display Error|OSNO OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000055605|07/05/2018|priority 3 |Q3|Unknown|Unknown|SCM  Water in silicon after hyperbaric|NOCO ATCO NOTE NOPT|Silicone hose in hyperbaric chamber.|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Assembly |Improperly Installed
ZF|P7000024191|21/09/2012|priority 2 |Q3|Unknown|Unknown|SRT Global 8 can bus and Serial Line S2|NOTE NOCO ATCO NOPT|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100035013|27/05/2014|priority 2 |Q3|Unknown|Unknown|Procedure needs to be revised|NOCO NOTE|HFT procedure corrected|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZB|100069556|30/09/2015|priority 1 |Q1|SUNCOR|Unknown|SCM LEAKING FLUID|DLFL ATCO NOTI NOCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100064910|31/05/2016|priority 2 |Q1|Unknown|Unknown|Åsg BB071 SCM failed on rig after mob DT|NOTE NOCO ATCO NOPT|Short circuit component on SCM|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|27/01/2016|priority 1 |Q3|Unknown|Unknown|Filtro com sinal de oxidação|ATCO NOTE NOCO NOPT|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Equipment Malfunction
ZF|100052701|19/09/2016|priority 1 |Q3|Unknown|Unknown|Corrosion on SCM|ATCO NOCO NOTE|Left in yard and not returned to Custome|Damage |Damage from corrosion|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000103208|12/05/2014|priority 3 |Q3|Unknown|Unknown|Test Error/Exxon/SCM/Exposed to Short|NOPT ATCO NOCO NOTE|Test Error|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P6000058949|01/12/2017|priority 3 |Q3|Unknown|Unknown|DHI205 test contains misleading info|ATCO NOCO NOTE|Unknown|Documentation Requirement |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Documentation Requirement |Input requirements incorrect / ambiguous
ZF|P6000104112|11/11/2014|priority 3 |Q3|Unknown|Unknown|Have no link up on EC3 etherscoptest.|NOCO ATCO NOTE NOPT|Followup towards supplier: QN200416823|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZB|100017278|27/02/2008|priority 4 |Q1|STATOIL|NORTH SEA|Reconstruction of equipment|ATCO NOCO NOTE NOPT|Lack of  communication lines|Documentation |Missing user documentation (customer)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Planning error
ZF|7105597|30/04/2010|priority 2 |Q3|PETRO SA; MOSSEL BAY|Unknown|Deviation on compensation system|ATCO NOTE NOPT NOCO|Couse is not related to CS|FMC Other Defect |Functional|Manufacturing/Quality - General|Fixtures|Manufacturing Engineering|ME routing
ZE|P7000039672|28/10/2016|priority 3 |Q3|Unknown|Unknown|MMR - Screw/Securing Plate from El. Can|NOTE ATCO NOCO|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Assembly |Damaged during lifting
ZF|P7000039672|20/03/2014|priority 3 |Q3|Unknown|Unknown|Teste de Hélio não aprovado.|NOTE NOPT NOCO ATCO|||Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Assy |No Non-Compliance
ZF|P6000088751|26/09/2012|priority 3 |Q3|Unknown|Unknown|Broken silicone bladder compensator|NOCO NOPT NOTE ATCO|Installation error of compensator.|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Compensator|FMC Assy |Operator Error
ZD|100048038|29/05/2008|priority 3 |Q2|Unknown|Unknown|No DBI referencing this material|ATCO NOCO NOTE NOPT|No DBI Available|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P6000031350|28/11/2013|priority 3 |Q3|Unknown|Unknown|Equipment located outside of warehouse|NOTE NOCO ATCO|Equipment not stored according to proced|FMC Other Defect |Functional|FKS Quality system issues|Product Realization|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000105708|17/03/2014|priority 3 |Q3|Unknown|Unknown|No reading on EC3 pin 9 and 10|NOPT NOCO NOTE ATCO|Workmanship during wiring  TBC in RCA|Test Related |OBS-Function|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Damaged during assembly
ZF|7102643|17/03/2010|priority 2 |Q3|STATOIL|NORTH SEA|F&D Mobilization not performed on SCM|NOTE NOCO NOPT ATCO|Conditionbased maintenance not performed|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Lack of Maintenance
ZF|P7000020444|19/03/2012|priority 1 |Q3|Unknown|Unknown|coupler´s não montam|NOPT NOTE NOCO ATCO|Mabotec|Desvio oriundo de tranporte na fábrica|Solicitação de concessão|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Other causes/damage |Damage during transport
ZF|P7000016420|26/10/2010|priority 2 |Q3|Unknown|Unknown|medida da screw fora da tolerância|NOTE ATCO NOPT NOCO|Montagem Issue|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Material error
ZF|100035013|06/11/2014|priority 3 |Q3|Unknown|Unknown|MEG present in the Hydraulic system|ATCO NOTE NOCO|ROXTHI operation in 2012  ref. 300346456|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Other external causes |Customer Error/responsibility
ZF|P6000105542|03/12/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|100054943|10/06/2015|priority 4 |Q3|Unknown|Unknown|(CDM)WOODSIDE KBSB SCM - HFT ISSUES|NOCO NOTE ATCO NOPT|HFT issues|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000058949|11/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE NOPT NOCO ATCO|Wrong type of screws used on valves|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100049000|12/02/2015|priority 3 |Q3|Unknown|Unknown|DCV leakage outside acceptance criteria|NOCO NOTE ATCO NOPT|Specification to be updated|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100052701|07/05/2013|priority 1 |Q3|STATOIL|NORTH SEA|Tyrihans 2 Leakage|ATCO NOTE NOCO|Screws not torqued on adapter plate.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000104112|18/08/2014|priority 4 |Q3|Unknown|Unknown|Update KS200e SW for Egina|NOCO ATCO NOTE|Com. functionality which was not cons.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000088751|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000063531|27/11/2015|priority 3 |Q3|Unknown|Unknown|Acoustic Leak Detector test in HFT|ATCO NOPT NOCO NOTE|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100017278|12/05/2015|priority 3 |Q3|Unknown|Unknown|Silicone in SEM. Reason unknown|NOTE ATCO NOCO|Silicone found inside SEM during RIT|FMC Other Defect |Physical|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Assy |Damaged during assembly
ZF|P6000104116|17/10/2016|priority 3 |Q3|Unknown|Unknown|POWER TEST FOR SCM ISSUE with Procedure|NOTE ATCO NOCO|Unknown|Documentation Requirement |Procedure / Process Error|Object Types to Eng Matl CLASS|iwcm_assy|Documentation Requirement |Ambiguous / unclear
ZF|P7000016420|05/09/2011|priority 1 |Q3|Unknown|Unknown|Extension Rod P55-10|NOTE ATCO NOCO NOPT|REVESTIMENTO|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Locking Mechanism|QA/QS/QI Related|Goods Receiving Inspection error
ZB|100020278|06/02/2008|priority 2 |Q1|EXXONMOBIL|Unknown|Communications failure Line A on SCM 25|NOCO ATCO NOPT NOTE|Communications failure Line A on SCM 25|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other PCBs|Vendor related |Equipment Malfunction
ZB|P6000105708|14/08/2014|priority 2 |Q1|Unknown|Unknown|Julia Claim 001 SRM Silicone bladders|NOCO NOTE ATCO|Design of bladder volume incorrect|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZE|P6000088604|22/06/2016|priority 3 |Q3|Unknown|Unknown|(CDM) Wheatstone SCM Communication error|NOCO ATCO NOTE|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P7000024900|16/10/2013|priority 1 |Q3|Unknown|Unknown|Outer Can does not mount|ATCO NOPT NOTE NOCO|101545 - KRISTIANSANDS SKRUEFABRIKK|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Final Inspection Error
ZF|P7000024900|10/02/2012|priority 1 |Q3|Unknown|Unknown|CVHP 53 and CVHP 54 are crossed|NOCO ATCO NOPT NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100052701|22/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|SCM com.  problems Tyrihans A4 SEM B|NOTE NOPT NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100018082|13/12/2012|priority 2 |Q3|Unknown|Unknown|Delivery of el-boards from 0300 KOS1|NOTE ATCO NOCO|New prosess will be implemented 01.08.13|FMC Other Defect |Physical|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Materials/Stores related |Improper Handling
ZF|P6000080343|29/11/2011|priority 3 |Q3|Unknown|Unknown|Missing signal on Ch 19  index 35 in ETU|NOTE NOPT ATCO NOCO|Wrong wiring spec|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Projects Related|Documentation error
ZF|P6000068918|03/04/2012|priority 3 |Q3|TOTAL|Unknown|Silicon leakage after hyperbaric test.|NOCO ATCO NOTE NOPT|Bladder hose adapter not tighten|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Compensator|FMC Assy |Operator Error
ZF|P6000069056|05/10/2011|priority 3 |Q3|STATOIL|NORTH SEA|Wiring on  EC 8:3 4 & 7 8 crossed Canbus|NOTE NOCO NOPT|Human failure  wrong wiring (spec is OK)|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000001843|22/05/2018|priority 3 |Q3|PETROBRAS|Unknown|MMR - Strainer Leakage|NOTE ATCO NOCO|Unknown Cause|TEST |Leak|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Other- Specify in comments
ZF|P6000068924|13/02/2012|priority 3 |Q3|TOTAL|Unknown|Errors in the new config|NOTE NOCO ATCO NOPT|Corrected Config for SmartTool required|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P6000058949|30/03/2011|priority 3 |Q3|Unknown|Unknown|Update MF-0000020212|ATCO NOCO NOTE|Update of important notice document|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000058949|05/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE NOCO ATCO NOPT|Incorrect screw quality used in BOM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000101955|06/07/2015|priority 2 |Q3|STATOIL|NORTH SEA|SCMMMR Tyrihans 3 broken  Bracket bolts|ATCO NOTE NOCO|operator applied too high torque|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|7104033|13/02/2015|priority 3 |Q3|Unknown|Unknown|Raw oil and gas inside the SCM|NOCO ATCO NOTE|Caused by leakage in blind plate.|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100018082|18/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|Åsg F&D 20 SCM overdue mobilizing time|NOCO NOPT ATCO NOTE|SCM overdue mobilizing time|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|DCV/COV with Cobalt pilot ball|ATCO NOTE NOPT NOCO|DCV/COV with Cobalt pilot ball|Design |Material Master Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000088614|19/07/2017|priority 3 |Q3|Unknown|Unknown|Traceability miss match  non complience|NOTE ATCO NOCO|SN not consistency on all papers and SCM|Certification |Information incorrect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Assembly |Other- Specify in comments
ZE|100056261|12/03/2010|priority 3 |Q3|Unknown|Unknown|SEM Common Alarm|NOPT NOTE NOCO ATCO|Cancelled - customer caused|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000055605|28/09/2015|priority 3 |Q3|Unknown|Unknown|Too long tubing|NOCO ATCO NOPT NOTE|Tubes not made accoring to drawing|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Fabrication Shop Personnel |Operator error
ZF|P7000039672|08/10/2013|priority 1 |Q3|Unknown|Unknown|ECN  6147855 - PN  P7000039672|NOPT NOCO NOTE ATCO|ECN|Design |DBI Error|SS - Controls -Hydraulic Distribution|Other hydraulic components|FMC Engineering related |ECN Change
ZF|P7000001621|28/03/2012|priority 1 |Q3|Unknown|Unknown|Furação sem rosca|NOCO ATCO NOTE NOPT|faltou realizar uma rosca|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100018531|05/10/2015|priority 1 |Q3|SHELL|Unknown|MMR - Leakage through Lock. Mech.|NOTE NOCO ATCO|Fracture due to Hydrogen embrittlement|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Fabrication Shop Equipment |Gas Issues
ZF|P6000028371|23/08/2013|priority 3 |Q3|Unknown|Unknown|ETU Software 6.2|NOCO NOPT ATCO NOTE|ETU Software Error|Design |Procedure Error|SS - Controls - Topside Products|Other Topside Products|FMC Engineering related |Procedure error
ZF|7100320|16/02/2016|priority 3 |Q3|Unknown|Unknown|MMR - Broken Screw in Manifold Block|NOTE NOPT ATCO NOCO|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Improper handling
ZF|100035013|21/09/2010|priority 2 |Q3|SHELL|Unknown|Upgrade cpu 201 HW and SW|NOTE ATCO NOCO|CPU201 board has been upgraded|Design |Material Master Error|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOTE ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000043714|06/07/2011|priority 3 |Q3|PETROBRAS|GOM|Petrobras Cascade XT-SCM|ATCO NOCO NOPT NOTE|Petrobras Cascade XT-SCM|Test Related |OBS-Function|SS - Controls -Computer system software|200/150 SW|FMC Engineering related |Continuous Improvement
ZF|P6000068924|29/06/2012|priority 3 |Q3|Unknown|Unknown|Water inside module after hyperbaric|ATCO NOCO NOPT NOTE|Water inside module after hyperbaric|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 17|NOCO NOPT ATCO NOTE|Investigate Coupler Rotation-BPAT SCM 17|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZE|100035118|18/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM) Data conversion of SCM sensor|NOCO NOTE NOPT ATCO|Data conversion of SCM sensor|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000079984|21/09/2012|priority 1 |Q3|Unknown|Unknown|Possible failure of dim on m.blocks Dunf|NOPT ATCO NOCO NOTE|Ref QN 200283096|Machining Related |OBS-Length/Depth Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|100056918|28/08/2009|priority 2 |Q3|Unknown|Unknown|(SS) Range setting incorrect for chart|NOTE NOPT NOCO|Range setting incorrect for chart|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P7000024900|14/08/2014|priority 1 |Q3|Unknown|Unknown|Base Plate danificada / Damaged|NOPT ATCO NOTE NOCO|||Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Improper handling
ZF|P6000028371|01/04/2008|priority 2 |Q3|Unknown|Unknown|Shell reqested - process change|NOTE NOPT NOCO ATCO|Shell reqested - process change|Change/Deviation Request |Process substitution request|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100030542|21/08/2014|priority 3 |Q3|Unknown|Unknown|SCM Torqued down on TS w/Protection Caps|NOCO NOTE ATCO|SCM Torqued down on TS w/Protection Caps|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Test |Improper handling
ZB|P6000043714|31/03/2009|priority 2 |Q1|PETROBRAS|GOM|SCM and torque tool interface conflict.|NOPT ATCO NOCO NOTE|see longtext -torque tool  new or modify|Assembly Related |OBS-Interface issue|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |No Non-Compliance
ZF|7104033|19/11/2015|priority 3 |Q3|Unknown|Unknown|Water inside SCM after hyperbarictest|ATCO NOCO NOTE NOPT|Operator forgot to tighten test hose|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100026328|21/09/2010|priority 1 |Q3|Unknown|Unknown|Vazamento de silicone no SCM Viola SN 05|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|P6000091085|04/03/2013|priority 3 |Q3|Unknown|Unknown|SEM B lost connection during EETEST|ATCO NOTE NOCO NOPT|External failure  voltage drop in SPCTU|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000079984|07/02/2013|priority 1 |Q3|Unknown|Unknown|Wrong SEM supply voltage reading at ST|NOTE NOCO ATCO|Lack of calibr. procedure  ref NRB text|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Procedure error
ZF|P6000069056|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|Insufficient wall thickness in m. block|NOPT NOTE NOCO ATCO|Ref. QN 200241870|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
ZF|P6000093498|07/04/2014|priority 4 |Q3|Unknown|Unknown|Missing o-ring on transmitter|NOCO NOPT NOTE ATCO|O-Ring lost in FMC warehouse/workshop|FMC Other Defect |Part Lost|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Test |Missing Parts
ZF|P6000063531|23/01/2014|priority 2 |Q3|Unknown|Unknown|SCM not mobilized acc. to FMC procedure|ATCO NOCO NOPT NOTE|No test equipment available|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missing Parts
ZF|P6000064910|04/08/2011|priority 2 |Q3|TOTAL|Unknown|Leakage on inner barriere system|NOPT NOTE ATCO NOCO|Lakage in inner barrirer|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000105542|10/12/2014|priority Unknown|Q3|Unknown|Unknown|SCM manifold block failure - SN17|NOTE NOCO|Wrong welding pin defined for man. block|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZD|7104075|31/03/2014|priority 3 |Q2|Unknown|Unknown|SEM Xylan Coating|NOCO ATCO NOTE|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|SEM Can|Vendor related |Coating Defect
ZF|100056176|03/11/2009|priority 3 |Q3|STATOIL|NORTH SEA|Åsg F&D09 Mob not performed  on SCM|ATCO NOCO NOPT NOTE|No time for a mobilization of  the SCM|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|100020562|27/08/2009|priority 2 |Q3|BP|GOM|BPTH SCM 24 Nova DHI card issue|NOTE NOPT ATCO NOCO|BPTH SCM 24 Nova DHI card issue|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P7000001621|11/05/2010|priority 1 |Q3|Unknown|Unknown|NUT DANIFICADA|ATCO NOTE NOPT NOCO|Natural Corrosion of item|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000116166|10/04/2015|priority 3 |Q3|Unknown|Unknown|Gas leakage in fitting|NOTE ATCO NOPT NOCO|Incorrect assembly of fittings.|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|FMC Assy |Operator Error
ZF|P7000000897|07/08/2012|priority 1 |Q3|Unknown|Unknown|Leakage detected in LP supply coupler.|NOCO NOTE NOPT ATCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Vendor related |Equipment Malfunction
ZF|P7000000897|26/09/2011|priority 1 |Q3|SHELL|Unknown|Diâmetro incorreto.|ATCO NOTE NOPT NOCO|USILIDER - BASE PLATE|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
ZE|P6000088751|21/12/2012|priority 2 |Q3|Unknown|Unknown|Update KS200e SW to 610.0|ATCO NOTE NOCO|To Update KS200e SW to 610.0|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000068902|26/09/2012|priority 3 |Q3|Unknown|Unknown|LP return flowmeter will not count|NOTE NOCO NOPT ATCO|Machine Malfunction|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Flowmeter|FMC Machine Shop Equipment |Machine Malfunction
ZF|P6000068912|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SEM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000083428|13/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|Failure SEM Baseplate with penetrator|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZF|P6000068918|01/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No failure detected in extended testing|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|7104670|06/12/2008|priority 4 |Q1|STATOIL|NORTH SEA|F&D Hydraulic leak on SCM base|ATCO NOCO NOPT NOTE|Protection Caps still on couplers|FMC Other Defect |Physical|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000000897|15/06/2012|priority 1 |Q3|Unknown|Unknown|Scratch on Outercan surface|NOCO NOTE ATCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Damaged during assembly
ZB|P6000077638|05/02/2015|priority 1 |Q1|Unknown|Unknown|SCM delivered with wrong type restrictor|NOTE NOCO ATCO|Wrong flowrestrictor used in repeat SCM|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000000897|25/11/2011|priority 1 |Q3|Unknown|Unknown|Return Flow meter not working|NOPT NOTE NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Cause not found
ZF|P6000050867|19/07/2010|priority 1 |Q3|PETROBRAS|GOM|DAS loss of communication|NOPT NOTE NOCO ATCO|DAS loss of communication|FMC Other Defect |Functional|SS - Controls - Test and Transportation|Communication Test Unit (CTU)|Intercompany|FMC Kongsberg
ZF|100009059|08/07/2010|priority 2 |Q3|EXXONMOBIL|GOM|Part shipped without QA approval.|NOPT NOTE NOCO ATCO|Part shipped without QA approval.|Procurement |Purchase Order Incorrect|T & RC - Hydraulic/Pneumatic Eq.|Hydraulic/Pneumatic Unit|FMC Assy |Missing Operation
ZD|P6000062990|09/06/2015|priority 3 |Q2|Unknown|Unknown|ATS - Wrong Revision|NOTE NOCO ATCO NOPT|ECN|Documentation |Incorrect Certificates / Records|Vendor Quality system issue|Quality Management System|Vendor related |Specification not followed
ZF|P6000084242|31/10/2013|priority 4 |Q3|Unknown|Unknown|SEM A failure to communicate with SPCTU|NOCO ATCO NOPT NOTE|Communication failed|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000068924|08/05/2013|priority 1 |Q3|Unknown|Unknown|Wrong use of miniseal|NOCO ATCO NOTE|Instructions for use of miniseal|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Wire|FMC Engineering related |Continuous Improvement
ZF|P6000064909|12/04/2012|priority 2 |Q3|Unknown|Unknown|Planning error in bid|NOCO NOPT NOTE ATCO|Planning error in bid|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #7 Wiring|ATCO NOTE NOPT NOCO|BPTH SKOFLO SCM SN #7 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100048038|01/09/2014|priority 3 |Q3|Unknown|Unknown|Leakage on accumulator|NOPT NOCO ATCO NOTE|Internal leakage in accumulator  see ZD|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Products|Accumulator|Vendor related |Equipment Malfunction
ZD|P6000067533|12/10/2011|priority 1 |Q2|KIRINSKOYE SPS|Unknown|Kirinskoye SCM 04|NOCO ATCO NOTE|SCM mounted to SCMTS w/HC protective cap|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000122626|14/10/2015|priority 3 |Q3|Unknown|Unknown|Too high pressure applied to HP supply|NOCO ATCO NOPT NOTE|Failure on test equipment|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100048038|25/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|Wrong P/N for hyd. valve on SCM|NOPT NOCO ATCO NOTE|s/n 43899  assigned to incorrect p/n|Assembly/Test Related |Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P6000080733|09/04/2014|priority 2 |Q3|STATOIL|NORTH SEA|MMRSCM  Fram H Nord  SN 1  No Comm issue|ATCO NOTE NOCO|Wrong marking on wiring from penetrator|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000119335|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000001843|23/10/2015|priority 3 |Q3|PETROBRAS|Unknown|MMR - Wrong Assembly of Top Connectors|NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Connector|FMC Assy |Operator Error
ZF|P7000039672|20/12/2017|priority 1 |Q3|Unknown|Unknown|Falha de leitura PT|ATCO NOCO NOPT NOTE|Unknown|Electrical |Functional|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Equipment Malfunction
ZF|100016711|04/03/2011|priority 3 |Q3|BP|GOM|Vendor soldering non-conformance|NOTE ATCO NOCO|Vendor soldering non-conformance|Raw Material |OBS-Defects in material|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Operator Error
ZF|P6000068924|12/06/2012|priority 1 |Q3|TOTAL|Unknown|Loose HCs in manifold block.|NOCO NOTE ATCO NOPT|Followed up in QN 200296914|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Test |Incorrect set up/testing
ZD|P6000104111|13/08/2014|priority 1 |Q2|Unknown|Unknown|CERTS ISSUE|NOPT NOTE NOCO ATCO|VL Specification not followed|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|100050519|10/10/2012|priority 2 |Q3|TOTAL|Unknown|MOHO 12 DHI card|ATCO NOTE NOCO|Follow-up ref QN 200269268|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Clarification
ZD|P6000088751|15/01/2014|priority 3 |Q2|Unknown|Unknown|GWF SCM#3 SEMA CPU IN SUSPEND MODE|NOTE NOCO ATCO NOPT| SEM-A CPU IN SUSPEND MODE|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100016711|05/08/2011|priority 2 |Q3|BP|GOM|SCM 32 pitting on EC seal surfaces|NOTE NOCO ATCO|SCM 32 pitting on EC seal surfaces|Damage |Damage from corrosion|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000074156|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|7102643|19/03/2010|priority 4 |Q3|STATOIL|NORTH SEA|F&D 16 Not able to install SCM properly|NOCO NOTE NOPT ATCO|Incorrect placement of poppets|Assembly Related |OBS-Interface issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P6000057007|28/10/2010|priority 2 |Q3|Unknown|Unknown|RIT procedure issues|NOCO NOTE ATCO NOPT|RIT procedure issues|Design |Procedure Error|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Engineering related |Procedure error
ZF|100006609|06/05/2011|priority 1 |Q3|Unknown|Unknown|Falha de comunicacao SEM A|NOCO ATCO NOTE|SEM A_Falha na comunicação|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100020562|14/03/2009|priority 3 |Q3|BP|GOM|SCM- BPTH|NOPT NOTE ATCO NOCO|Prcocedural Error|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Design Error
ZF|P7000016420|07/12/2011|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 11|ATCO NOTE NOCO NOPT|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|3787102|07/05/2008|priority 2 |Q3|SNORRE|Unknown|Snorre WCM SN 08 overhaling SO-999480|NOCO ATCO NOTE|Unknown|Machining Related |Unknown|FKS Quality system issues|Quality Management System|FMC Assy |Missing Operation
ZF|100030542|30/10/2015|priority 3 |Q3|Unknown|Unknown|Cust Deviation to shipping procedure|NOCO ATCO NOPT NOTE|Customer Request|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|7102643|06/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|Missing HC24 and HC25|NOCO NOTE ATCO NOPT|Wrong configuration on SCM-SCMMB coupler|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Engineering Error
ZF|P7000016420|25/10/2011|priority 1 |Q3|Unknown|Unknown|Conector Eletrico - Outercan|NOTE NOCO NOPT ATCO|Unknown|Raw Material |OBS-Defects in material|SS - Controls - Electric Products|Electrical Connector|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000141559|03/01/2017|priority 3 |Q3|Unknown|Unknown|Wrong oiltype used during flushing.|NOTE NOCO ATCO|Used wrong hydraulic fluid|TEST |Damaged During Testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Test |Specification not followed
ZF|P6000088604|28/08/2012|priority 3 |Q3|Unknown|Unknown|Drawings|ATCO NOCO NOTE NOPT|Drawing error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000064911|27/05/2011|priority 2 |Q3|TOTAL|Unknown|mangler mini seal til trafo 3000volt|NOTE NOPT NOCO ATCO|Additional parts added to BOM.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|7104020|26/11/2013|priority 3 |Q2|Unknown|Unknown|Outer can stripes|ATCO NOTE NOCO|Coating Defect|Marking |Incorrect Size of Marking|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|P6000084906|18/11/2011|priority 3 |Q3|Unknown|Unknown|Wrong wiring EC8|ATCO NOCO NOPT NOTE|Incorrect wiring by operator.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000065528|05/04/2011|priority 1 |Q3|Unknown|Unknown|Inadequate Insulation of PSDM600|NOTE NOPT NOCO ATCO|Spec. improved  design upgraded|Coating/Plating |Coating not applied|SS - Controls - Electronic Boards|Power units|FMC Engineering related |Specification error
ZF|P6000093498|13/10/2015|priority 3 |Q3|Unknown|Unknown|WOCM -Fail to connect BMU-2B to consumer|NOTE ATCO NOCO|Software causing component failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100041392|25/06/2008|priority 3 |Q3|PETROBRAS|Unknown|Fitting damaged during outercan assembly|NOTE ATCO NOCO NOPT|Unknown|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZE|P6000063531|03/05/2017|priority 2 |Q3|Unknown|Unknown|Power supply error (Vigdis)|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100020278|11/02/2008|priority 2 |Q1|EXXONMOBIL|Unknown|SCM 26 communication problem|ATCO NOPT NOTE NOCO|Unknown|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|100049000|06/06/2011|priority 3 |Q3|BP|GOM|Replace HC 10 and HC 22|NOCO NOPT ATCO NOTE|Replace HC10 & HC22|Damage |Damage during assembly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZF|P6000093498|27/04/2015|priority 3 |Q3|Unknown|Unknown|Leakeage result to high|NOTE NOPT ATCO NOCO|Leakage of DCV|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Specification not followed
ZB|100017278|09/11/2013|priority 3 |Q1|Unknown|Unknown|Accidentally pressured up TRSCSSV|NOTE NOPT NOCO ATCO|Procedure not followed|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZD|P6000074156|16/07/2012|priority 3 |Q2|Unknown|Unknown|HPDCV 54 failure|NOCO NOTE|QN cancelled|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000069820|15/03/2012|priority 1 |Q3|CONOCOPHILLIPS|Unknown|(SS) SCM drop during transfering|NOPT NOTE ATCO NOCO|Improper handling|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Handling
ZF|P7000008275|07/09/2010|priority 1 |Q3|Unknown|Unknown|FALHA DE OPERAÇÃO DAS VÁLVULAS DO SCM|NOCO NOTE ATCO NOPT|Acionamento de DCV inoperante|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZB|100020562|24/07/2008|priority 3 |Q1|BP|GOM|Communications issue on SCM 17|NOTE NOCO NOPT|Communications issue on SCM 17|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor related |Equipment Malfunction
ZF|P6000126219|01/05/2017|priority 3 |Q3|Unknown|Unknown|SCM Dataplate Incorrect MAC Address|NOTE NOPT NOCO ATCO|Name plate has incorrect MAC address|Marking |Marking content error|Object Types to Eng Matl CLASS|scm_mkIIE|Intercompany|FMC Kongsberg
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOCO ATCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100001156|25/09/2015|priority 3 |Q3|Unknown|Unknown|Not able to perform Sand Sensor test.|NOPT ATCO NOCO NOTE|CPI test equipment not available|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Other causes/damage |Cause not found
ZF|P6000042308|11/12/2009|priority 3 |Q3|TULLOW|WEST AFRICA|Jubilee SCM procedure issues|NOTE NOPT NOCO ATCO|Jubilee SCM procedure issues|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Missed operation
ZF|P6000104112|05/05/2014|priority 4 |Q3|Unknown|Unknown|Damage on electrical connectors|ATCO NOCO NOTE NOPT|SCMTS SCMMB EC assembled w/o guidepin|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|Vendor related |Assembly error
ZF|P6000043122|12/10/2009|priority 3 |Q3|Unknown|Unknown|CIB600 board not working properly|NOCO NOTE NOPT ATCO|Error to be confirmed in QN200144382|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Material error
ZF|P7000016420|19/01/2011|priority 2 |Q3|Unknown|Unknown|Revestimento em desacordo com DBI.|NOTE NOPT ATCO NOCO|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Cause not found
ZF|P6000079032|01/06/2012|priority 3 |Q3|STATOIL|NORTH SEA|Communication error PSD|NOCO NOTE ATCO|See folowup QN for conclusion.|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Other causes/damage |Cause not found
ZF|P6000039844|27/11/2013|priority 3 |Q3|Unknown|Unknown|Lp adapterplate need adapter for tube.|NOTE NOPT ATCO NOCO|Assembly not created according to master|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000088626|18/05/2016|priority 2 |Q3|Unknown|Unknown|Torque tool (tt) interface on MCM and HC|NOCO NOPT ATCO NOTE|Wrong tolerances on DWG for MCM & HC|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZE|P6000121393|18/09/2015|priority 3 |Q3|Unknown|Unknown|Too high voltage vrong way|NOCO NOTE ATCO|Operator error  wrong jumper used|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|100049000|16/05/2012|priority 2 |Q3|BP|GOM|SCM 24 Visual inspection / Seal inspect|ATCO NOCO NOTE NOPT|SCM 24 Visual inspection / Seal Inspect|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZB|100035013|03/01/2010|priority 1 |Q1|SHELL|Unknown|Communication with SEM-B has failed|NOTE ATCO NOPT NOCO|Electronic board failure|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|100018082|22/03/2013|priority 3 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOPT ATCO NOCO NOTE|Lack of CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000058949|01/02/2011|priority 2 |Q3|Unknown|Unknown|Def. locking mechanism on CPU Rib.cables|NOTE NOCO ATCO NOPT|Damaged when disconnecting Ribbon Cables|Damage |Damage Due to Handling|SS - Controls - Electric Products|Electrical Harness|FMC Assy |Improper handling
ZF|P6000074156|13/11/2012|priority 1 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100035013|21/11/2014|priority 3 |Q3|Unknown|Unknown|Contamination of MEG in hydraulic system|ATCO NOCO NOPT NOTE|contamination of MEG in hydraulic system|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Cause not found
ZF|P6000042969|13/03/2010|priority 1 |Q3|TOTAL|WEST AFRICA|RIBS application sent to TIF card|NOCO NOTE ATCO NOPT|Incorrect documentation|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P7000000897|14/09/2011|priority 2 |Q3|Unknown|Unknown|Caixa do Manifold Block aberta|NOTE NOCO NOPT ATCO|NÃO HÁ NÃO CONFORMIDADE|FMC Other Defect |Functional|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |No Non-Compliance
ZF|P6000098616|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000121958|04/03/2015|priority 2 |Q3|Unknown|Unknown|Part does not fit|NOPT NOCO NOTE ATCO|Wrong hole patterns in SEM bracket|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|SEM Bracket|FMC Engineering related |DWG Error
ZF|100036232|09/11/2017|priority 2 |Q3|Unknown|Unknown|Shell Pierce engineering not completed|NOPR ATCO|Unknown|Design |DBI Error|FKS Quality system issues|Engineering System|FMC Engineering related |Engineering Error
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOCO NOTE NOPT ATCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZE|P6000122626|05/11/2015|priority 3 |Q3|Unknown|Unknown|Too high pressure applied to HP supply|NOTE ATCO NOCO|Action taken for prevent same in the fut|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Capture Mistake
ZE|100046112|22/06/2016|priority 3 |Q3|Unknown|Unknown|(CDM) Angel  SCM  Update HFT|NOCO ATCO NOTE|HFT procedure has been updated|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Documentation Requirement |Error in document / spec
ZB|100035013|15/04/2010|priority 2 |Q1|SHELL|Unknown|GC#003-SCM#20 Communication failure|NOPT NOTE NOCO ATCO|Wrong cam card|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Manufacturing Engineer Erorr
ZF|P7000001621|27/01/2011|priority 2 |Q3|Unknown|Unknown|DCV's com vazamento|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100067526|12/05/2017|priority 2 |Q3|Unknown|Unknown|CR:Hyperbaric pressure test notperformed|NOCO ATCO NOPT NOTE|Hyperbaric test not included in PO|TEST |Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000039672|26/08/2014|priority 4 |Q3|Unknown|Unknown|Falta de materiais na montagem mecânica|NOCO NOPT NOTE ATCO||131969 - PARKER HANNIFIN INDUSTRIA E|FMC Other Defect |Part Lost|SS - Controls -Instrumentation|Other mechanical components|FMC Assy |Missing Parts
ZF|100018531|11/11/2013|priority 1 |Q3|Unknown|Unknown|QA não Convocada / QA not convened|NOPT NOTE NOCO ATCO|Documentation process fault|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|7101463|16/08/2010|priority 3 |Q3|Unknown|Unknown|Megi SCM Test Procedure issues|ATCO NOCO NOTE NOPT|Megi SCM Test Procedure issues|Design |Procedure Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|P7000024900|15/06/2012|priority 1 |Q3|Unknown|Unknown|Concessão P600007731 -> 708-909-002|NOPT ATCO NOTE NOCO|Concessão para substituição|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000065886|24/04/2012|priority 1 |Q1|ENI|NORTH SEA|SEM B no communication with Well N-2H|NOTE ATCO NOCO|Faulty board|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZE|P6000043714|21/09/2009|priority 2 |Q3|PETROBRAS|GOM|No standard for SCMMB drawing views|NOCO NOPT NOTE ATCO|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Documentation
ZF|P7000024191|16/11/2012|priority 1 |Q3|Unknown|Unknown|SRT - GLOBAL #12 CAN BUS AND SERIAL LINE|NOPT NOCO NOTE ATCO|Lab test box with problem.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100037966|08/10/2008|priority 3 |Q3|BP|Unknown|High pressure on return system|ATCO NOCO NOTE NOPT|new technician|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Lack of Training
ZF|P7000039672|27/06/2013|priority 1 |Q3|Unknown|Unknown|Wrong PN engraved / PT com PN errado|ATCO NOPT NOCO NOTE|SCAN SENSE|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Final Inspection Error
ZD|P6000042308|20/07/2016|priority 3 |Q2|Unknown|Unknown|Incorrect coating spec. rivision|NOTE ATCO NOCO NOPT|Incorrect coating spec. rivision|Documentation |Incorrect Certificates / Records|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Documentation
ZF|100056443|16/12/2010|priority 2 |Q3|Unknown|Unknown|SW confusion during MMR activity|NOPT NOTE NOCO ATCO|Unknown|Documentation |Procedure / Process Error|SS - Controls -Computer system software|Basis 200e SW|FMC Engineering related |Procedure error
ZE|7104033|09/09/2016|priority 3 |Q3|Unknown|Unknown|Too high voltage used on SCM (388 VAC)|ATCO NOTE NOCO|Name plate marked with too high voltage|TEST |Damaged During Testing|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Marking |Incorrect Marking
ZF|P6000101955|19/03/2014|priority 4 |Q3|Unknown|Unknown|crack in the blader|NOTE ATCO NOCO NOPT|Too high pressure during topping of SCM|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000062990|11/08/2015|priority 1 |Q3|Unknown|Unknown|SCM #1 Built to rev D|ATCO NOTE NOPT NOCO|Wrong class used on ECN|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Error
ZF|P6000069056|10/07/2012|priority 3 |Q3|Unknown|Unknown|Short-circuit in wiring|NOPT NOTE NOCO ATCO|Accidental opr err.  wiring now reworked|Test Related |OBS-Component Error|SS - Controls - Electric Products|Electrical Components|FMC Assy |Operator Error
ZF|100015314|19/10/2010|priority 2 |Q3|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|Unknown|Material not delivered to plant|ATCO NOPT NOCO NOTE|Taken into Aberdeen under wrong Project|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|100052388|06/06/2012|priority 1 |Q3|STATOIL|NORTH SEA|Short curcuit wiring to SEM A  no com.|NOPT NOCO NOTE ATCO|Short curcuit wiring to SEM A  no com.|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000029772|27/08/2009|priority 3 |Q3|ENGIE|NORTH SEA|Communication problems|NOTE ATCO NOCO NOPT|Vendor recommended TRITON update|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|Vendor related |Unknown
ZE|P6000103208|10/11/2014|priority 2 |Q3|Unknown|Unknown|Damaged boards due wrong ext connection|ATCO NOPT NOCO NOTE|Defective external wiring applied|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Houston
ZF|100035013|10/08/2010|priority 3 |Q3|Unknown|Unknown|ACM  need SEM reset after ACM powercycle|NOCO NOTE NOPT ATCO|SEM reset after ACM powercycle|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|P7000039672|20/05/2014|priority 4 |Q3|Unknown|Unknown|FALTA DE ORING|NOTE NOPT NOCO ATCO|1021 - Teledyne Oil and Gas|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Missing Parts
ZF|P6000104112|06/02/2015|priority 3 |Q3|Unknown|Unknown|SCM flow restriction outside criterita|NOCO ATCO NOPT NOTE|Missing information in procedure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOCO NOTE NOPT ATCO|Incorrect screw quality used in BOM|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZE|P6000125394|26/08/2015|priority 3 |Q3|Unknown|Unknown|Internal leakage too high from DCV's|NOTE NOCO ATCO|Vendor improved process|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000068924|08/03/2013|priority 2 |Q3|Unknown|Unknown|communication test of the M101|ATCO NOCO NOTE|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|7104670|09/04/2018|priority 2 |Q1|Unknown|Unknown|HEI OH054_ No DHgauge readings from SEMA|NOTI OSTS NOPR|Unknown|Software |Program configuration|Object Types to Eng Matl CLASS|scm_mkIII|Software |Other- Specify in comments
ZF|100035118|03/09/2014|priority 2 |Q3|WOODSIDE|Unknown|Water in silicone sample after hyperbari|NOCO ATCO NOTE|Reason for leakage not found.|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOPT NOTE NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000063531|18/12/2015|priority 2 |Q3|Unknown|Unknown|DHI 205 Test in HFT|ATCO NOPT NOTE NOCO|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P7000000897|18/10/2010|priority 1 |Q3|Unknown|Unknown|RM 151 FAIL|NOTE NOPT ATCO NOCO|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|P6000063531|09/04/2017|priority 1 |Q1|Unknown|Unknown|Vigdis FD027 Sensor reading fault G1 SCM|NOTE NOCO ATCO|Unknown|Software |Functional|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|P7000008275|15/04/2014|priority 1 |Q3|Unknown|Unknown|DIÂMETRO (SUCATA)|ATCO NOCO NOPT NOTE|Unknown|Machining Related |OBS-Inside Diameter Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZB|P6000091085|21/10/2015|priority 2 |Q1|Unknown|Unknown|OWIRS Accidental Disconnect Initiation|NOCO NOTE ATCO|Unknown|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Other Eletronic Boards|Intercompany|FMC Houston
ZE|7103234|05/11/2014|priority 3 |Q3|Unknown|Unknown|NCR 313417 SCM Accumulator no pre-charge|NOCO NOTE ATCO NOPT|Unknown|Test Related |OBS-Missed Operation|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Service Related:|Improper job preparation
ZF|100037427|03/03/2009|priority 3 |Q3|TOTAL|WEST AFRICA|Blinded smart return line|NOTE NOPT ATCO NOCO|1st  occurance  no changes to procedure|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|100056443|22/07/2010|priority 1 |Q3|EDISON/EDF|NORTH SEA|SCM not mobilized according to PSM|NOTE NOPT ATCO NOCO|SCM not mobilized according to PSM|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Customer Error
ZF|P6000104116|09/07/2014|priority 4 |Q3|Unknown|Unknown|Damaged sealing surfaces|NOPT NOTE NOCO ATCO|Damage on sealing surfaces|Machining Related |OBS-Surface Finish Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZB|100052231|31/03/2009|priority 1 |Q1|CHEVRON|GOM|SIO alarm causing a shutdown.|NOTE NOCO ATCO|SIO alarm causing a shutdown.|Test Related |OBS-Function|Software  FKS provided|SEM|FMC Engineering related |Engineering Error
ZF|P7000039672|20/03/2017|priority 1 |Q3|Unknown|Unknown|Top Plate não Monta na Outer Can|NOPT ATCO NOCO NOTE|Unknown|Assembly |Misalignment / Interface Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000105542|30/10/2013|priority 3 |Q3|Unknown|Unknown|Too high internal leakage|NOCO NOPT NOTE ATCO|Too high internal leakage on DCV|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000074156|03/07/2017|priority 2 |Q3|SHELL|Unknown|Short circuit because of test equipment|ATCO NOTE NOCO|mismatch between connector numbering|TEST |Damaged During Testing|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Test |Incorrect set up/testing
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO ATCO NOTE NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|100057723|24/11/2008|priority 2 |Q1|LLOG|Unknown|Failure to pass low pressure testing.|ATCO NOCO NOTE|Unknown|FMC Other Defect |Physical|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Other causes/damage |Damage from Wear and Tear
ZB|100035400|12/02/2008|priority 2 |Q1|HESS|GOM|RAM Warning on SEM B|NOCO NOTE NOPT ATCO|RAM Warning on SEM B|Assembly/Test Related |Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Equipment Malfunction
ZF|P6000138873|14/12/2016|priority 3 |Q3|Unknown|Unknown|Wrong revision on penetrator|NOTE NOCO ATCO NOPT|Old REV of SEM on Stock|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Other causes/damage |No Non-Compliance
ZF|100036232|05/05/2015|priority 2 |Q3|Unknown|Unknown|Applied HP on LP during hyperbaric|NOTE NOPT ATCO NOCO|Operator error  test set-up improved|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|100051992|04/05/2013|priority 2 |Q3|Unknown|Unknown|Enfield - SCM Issue|NOCO ATCO NOTE NOPT|SCM Issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000058949|18/11/2014|priority 3 |Q3|Unknown|Unknown|E-probe simulator not working|NOTE ATCO NOPT NOCO|E-probe simulator not working|Test Related |OBS-Function|SS - Controls - Test and Transportation|Sensor Simulator (SESI)|FMC Test |Damaged during testing
ZF|P6000037215|08/12/2010|priority 3 |Q3|Unknown|Unknown|Gjøa - El. Actuators problem|NOTE NOPT NOCO|FMC Engineering related: Engineering Err|FMC Other Defect |Functional|SS - Controls - Electric Products|Other Electric Products|FMC Engineering related |Engineering Error
ZB|100001156|12/02/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 215|NOTE NOCO|Reported leakage not found in inspection|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|Missing sign offs|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZD|100052701|11/11/2009|priority 3 |Q2|STATOIL|NORTH SEA|Internal leakage in HP function valve|NOPT NOCO ATCO NOTE|Damage on pilot seat sealing surface|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000063632|08/11/2010|priority 2 |Q3|AQUILA PHASE 2|Unknown|Wrong presure test prosedure|ATCO NOCO NOTE NOPT|Wrong test procedure linked to SCM|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZB|100001156|11/02/2010|priority 1 |Q1|STATOIL|NORTH SEA|SCM Internal hydr. leak|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|FKS Quality system issues|Quality Management System|Vendor related |Coating Defect
ZF|P6000105542|06/12/2013|priority 3 |Q3|Unknown|Unknown|Leakage test faild during FAT|NOCO NOTE ATCO NOPT|Too high and unstable leakage from DCVs|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZD|100056261|11/04/2011|priority 3 |Q2|MURPHY|Unknown|NONCONFORMANCE TO FUNCTIONALITY REQ|ATCO NOTE NOPT NOCO|NONCONFORMANCE TO FUNCTIONALITY REQ|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100050519|20/09/2011|priority 2 |Q3|TOTAL|Unknown|Leakage from HP Supply to pilot|ATCO NOCO NOTE NOPT|Leakage from HP Supply to pilot|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P6000080343|11/06/2012|priority 3 |Q3|Unknown|Unknown|poor wiring connection|NOTE ATCO NOCO|Wiring error. Operator error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #14 Wiring|ATCO NOCO NOTE NOPT|BPTH SKOFLO SCM SN #14 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000116166|12/11/2014|priority 3 |Q3|Unknown|Unknown|Tullow Ten 10B Powerline fails (ESS:BI)|NOCO ATCO NOTE|Bad wiring connection (corrected)|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000088626|10/12/2014|priority Unknown|Q3|Unknown|Unknown|Missed BP Pre-production notification|NOTE NOCO ATCO|Requirement in ITP not followed|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000057855|11/02/2010|priority 3 |Q3|ENI|Unknown|Communication failure SEM|NOPT NOTE ATCO NOCO|Error to be confirmed in QN200153740|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZB|100050520|28/01/2010|priority 2 |Q1|Unknown|Unknown|Fault on IRCD|NOTE ATCO NOCO|IRCD's would not release|Design |Specification Error|SS - Compl. & W.Over - XT - General|External Tree Cap|FMC Engineering related |Specification error
ZF|P6000105542|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000132097|06/02/2019|priority 1 |Q3|Unknown|Unknown|DOCUMENTATION ISSUE|NOCO ATCO NOTE|Unknown|Marking |Marking content error|Object Types to Eng Matl CLASS|scm_mkIII|FMC Engineering related |DBI error
ZF|P6000116166|12/04/2016|priority 3 |Q3|Unknown|Unknown|Blank labels were installed on Elec. Cap|NOCO OSTS NOPT DLFL|Customer requested change|FMC Other Defect |Physical|SS - Controls - Electric Products|Electrical Harness|FMC Other causes/damage |Planning error
ZF|100034440|19/08/2011|priority 3 |Q3|Unknown|Unknown|Procedure issue with ETU|NOPT ATCO NOTE NOCO|Procedure issue with ETU|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000104111|16/03/2016|priority Unknown|Q3|Unknown|Unknown|Voltage reading out of range|NOCO ATCO NOTE NOPT|Voltage value to be reviewed|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZE|P6000102687|11/06/2015|priority 1 |Q3|Unknown|Unknown|WOCM installed with plastic protection|NOCO NOTE ATCO|Operator error|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000090632|23/06/2015|priority 2 |Q3|CHEVRON|Unknown|Wheatstone WO03 SN2 - Water Ingress|ATCO NOCO NOTE|Operator error  lack of knowledge|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P1000018406|02/11/2011|priority 3 |Q3|BP|GOM|Incorrect bolts|NOPT NOTE NOCO ATCO|Incorrect bolts|Design |DBI Error|SS - Controls -SCMMB|Mountingbase Plate|FMC Engineering related |DBI error
ZF|P7000001843|02/01/2012|priority 1 |Q3|Unknown|Unknown|AMASSAMENTO NA OUTERCAN|NOCO NOTE ATCO NOPT|Equipamento retornou do campo|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|100049000|20/12/2008|priority 2 |Q3|Unknown|Unknown|Material substitution|ATCO NOTE NOCO NOPT|Unknown|Change/Deviation Request |Part substitution request|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Other causes/damage |No Non-Compliance
ZB|P6000062454|07/04/2011|priority 1 |Q1|DAEWOO|Unknown|(SS): HHI SCM #1 Leaking COVLP|NOPT ATCO NOTE NOCO|Request by FKS|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Control Valve|Intercompany|FMC Kongsberg
ZE|P6000074156|28/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM)Prellude - to blank out the ESRS|NOPT NOTE NOCO ATCO|Prellude - to blank out the ESRS|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000109194|09/04/2014|priority 4 |Q3|Unknown|Unknown|Internal nitrogen leakage on SCM|NOPT NOCO NOTE ATCO|Collar not ajusted correctly|Test Related |OBS-Leakage (gas)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100056443|25/07/2018|priority 2 |Q1|Unknown|Unknown|Manifold Ethernet jumper interupting com|NOCO NOTE ATCO NOPT|manifold eternet jumper interupting coms|Documentation Requirement |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|P7000016420|05/11/2010|priority 1 |Q3|Unknown|Unknown|CHANGE-OVER NÃO CONFORME|NOTE NOPT ATCO NOCO|Rotator|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Final Inspection Error
ZB|100020278|29/10/2009|priority 2 |Q1|EXXONMOBIL|Unknown|06-MEGI-037 PT1 won't read while on HMI|NOCO NOTE ATCO|Cause not Found- W Ind to investigate|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZD|100049000|04/11/2010|priority 3 |Q2|Unknown|Unknown|Missing Required Docs per DBI-ATS Submit|NOCO NOTE NOPT ATCO|Missing Requied Docs per DBI|Documentation |Missing Certificates / Records|Vendor Quality system issue|Quality Management System|Vendor related |Specification not followed
ZF|P6000100953|03/06/2013|priority 3 |Q3|Unknown|Unknown| marking conflict on drawings|NOPT ATCO NOTE NOCO|Marking conflict on drawings|Documentation |Procedure / Process Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZF|100001156|26/02/2015|priority 1 |Q3|Unknown|Unknown|Reduction in mobilization scope|NOTE NOPT ATCO NOCO|Too short notice by customer|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|R303 and R305 PWV shutdown|NOCO NOPT NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|7104033|21/01/2013|priority 3 |Q3|Unknown|Unknown|Lack of documentation|ATCO NOCO NOTE NOPT|Unkown|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|10/11/2015|priority 1 |Q3|Unknown|Unknown|Não é possivel obter boot do MRM82A|ATCO NOTE NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Other Eletronic Boards|Intercompany|FMC Kongsberg
ZD|100017997|10/12/2012|priority 3 |Q2|Unknown|Unknown|No Communication to Conmpass Sensor|NOCO ATCO NOTE|No Communication to Conmpass Sensor|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZB|P6000058949|07/04/2016|priority 2 |Q1|Unknown|Unknown|GF - SCM - Hydraulic Leakage|NOTE NOCO NOPT ATCO|Customer Error/responsibility|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|Other external causes |Customer Error/responsibility
ZF|100049000|21/04/2008|priority 3 |Q3|BP|GOM|PRD-0000020064 not performed|NOPT ATCO NOCO NOTE|missed procedure step|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000121268|20/01/2015|priority 3 |Q3|Unknown|Unknown|Missmatch S/N label/Part|ATCO NOTE NOPT NOCO|Part labeled with wrong S/N in stock|Marking |Marking content error|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Materials/Stores related |Operator Error
ZF|P7000016420|28/09/2011|priority 1 |Q3|Unknown|Unknown|Base Plate não conforme|NOCO ATCO NOTE NOPT|USILIDER - BASE PLATE|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|DCV/COV with Cobalt pilot ball|NOTE NOPT ATCO NOCO|DCV/COV with Cobalt pilot ball|Design |Material Master Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZB|100017278|01/09/2008|priority 2 |Q1|STATOIL|NORTH SEA|HP Line in SCM leaking!|NOTE ATCO NOPT NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|FMC Other causes/damage |Unknown
ZD|P6000083428|14/10/2013|priority 1 |Q2|Unknown|Unknown|Part/Cert Issue|NOTE ATCO NOCO|Unknown|Documentation |Incorrect Certificates / Records|SS - Controls - Test and Transportation|SCM Lifting Tool|Intercompany|FMC Kongsberg
ZB|P7000002082|02/05/2017|priority 2 |Q1|PETROBRAS|Unknown|PRA-1 - Fechamento do módulo de P-55|ATCO NOTI NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|100035014|09/10/2008|priority 3 |Q1|STATOIL|Unknown|SEM-A has I/O-card problems|ATCO NOCO NOTE NOPT|I/O card possibly defect|Damage |Unknown|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes/damage |Cause not found
ZB|100048038|06/01/2010|priority 2 |Q1|CHEVRON|WEST AFRICA|Communication Failure with SEM B|ATCO NOTE NOCO|Communication Failure with SEM B|FMC Other Defect |Functional|Subsea Control Module (SCM) Electrical|Other SCM Electrical|Vendor related |Equipment Malfunction
ZF|P7000016420|30/06/2011|priority 1 |Q3|Unknown|Unknown|Protection Ring não monta|NOPT NOTE NOCO ATCO|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|P6000028371|20/01/2009|priority 3 |Q3|SHELL|GOM|Water in SCM after Hyperbaric Test|NOPT NOTE ATCO NOCO|worn test equipment|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Tooling
ZF|7104075|07/05/2012|priority 3 |Q3|Unknown|Unknown|Internal PT Acc Criteria in HFT Prd.|NOTE ATCO NOPT NOCO|Internal PT Acc Criteria in HFT Prd.|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000121268|02/09/2015|priority 3 |Q3|Unknown|Unknown|Wrong position assembled on PTs|NOPT NOTE ATCO NOCO|Position and wiring error|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000016420|05/06/2012|priority 1 |Q3|Unknown|Unknown|CPU com desvios|NOTE NOCO NOPT ATCO|ECN Class 1||Change/Deviation Request |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Intercompany|FMC Kongsberg
ZE|100020562|12/08/2009|priority 1 |Q3|BP|GOM|CAR 1 RCA Actions_2 from RPT10033107|NOTE ATCO NOCO NOPT|Implement RCA RPT10033107 Recommendation|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Causes for Improvement|Documentation
ZB|100050519|15/10/2009|priority 2 |Q1|Unknown|Unknown|Silicon Leak and Burst Bladder in SCM|NOTE NOCO ATCO|Silican leak and burst bladder|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Manufacturing Engineer Erorr
ZF|P6000121393|18/08/2015|priority 3 |Q3|Unknown|Unknown|Hydraulic fluid inside the SCM|ATCO NOPT NOTE NOCO|External leakage on COV.|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZB|100050519|04/09/2014|priority 2 |Q1|Unknown|Unknown|SCM was delivered with damaged outercan.|NOCO NOTE ATCO|Unknown|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZD|P6000028371|05/01/2015|priority Unknown|Q2|Unknown|Unknown|Bead blast name plate|NOPT ATCO NOCO NOTE|Unknown|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Operator Error
ZF|P7000039672|08/05/2014|priority 1 |Q3|Unknown|Unknown|Ausência dos Printouts|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZE|P6000088604|20/06/2017|priority 1 |Q3|Unknown|Unknown|Wheatstone  SCM  Clash issue|ATCO NOTE NOCO|Dimension (max & min height) varies|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Assembly |Other- Specify in comments
ZB|7102969|15/02/2010|priority 3 |Q1|MOBIL EG|Unknown|Filter Board Burn Damage|ATCO NOCO NOPT NOTE|Filter Board Burn Damage|Damage |Damage during testing|Customer Compliant|Noncompliance to Customer Requirement|FMC Test |Damaged during testing
ZF|P6000098616|27/06/2013|priority 2 |Q3|Unknown|Unknown|HS CAN bus grounding error on CPU card|NOPT ATCO NOCO NOTE|ISO GND missed in wiring specification|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P1000018406|14/03/2014|priority 2 |Q3|Unknown|Unknown|Tubing Touching Other Surfaces|NOPT NOCO ATCO NOTE|Tubing Touching Other Surfaces|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100037967|10/04/2008|priority 2 |Q3|BP|Unknown|FPSO NCR 029 - SCM P09 SEM Addresses|NOCO NOPT NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Unknown
ZF|P6000069056|01/02/2012|priority 1 |Q3|STATOIL|NORTH SEA|Earth fault on P6000062266 LNCS602|NOCO NOTE NOPT ATCO|Improved earth strap assembly|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000122626|10/08/2015|priority 3 |Q3|Unknown|Unknown|wrong lenght|NOTE NOCO ATCO NOPT|Tubes dimension did not fit for SCM615|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOPT NOTE ATCO NOCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|Vendor related |Material error
ZF|P6000122626|11/09/2015|priority 3 |Q3|Unknown|Unknown|Error in el design|ATCO NOPT NOTE NOCO|Wrong rev. 17 ea updated to rev B|Design |Specification Error|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Design Error
ZF|100058509|27/05/2010|priority 1 |Q3|Unknown|Unknown|LLOG GC448 fast scan issue|ATCO NOCO NOTE NOPT|MCS receives rubbish fastscan data from|FMC Other Defect |Functional|SS - Controls - Topside Products|N/A SW|Intercompany|FMC Kongsberg
ZF|P7000024900|03/06/2013|priority 1 |Q3|Unknown|Unknown|Não Conformidade na Base Plate.|ATCO NOTE NOPT NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Cause not found
ZF|P7000001843|03/01/2012|priority 2 |Q3|Unknown|Unknown|Problemas com o simulador PDG.|NOTE ATCO NOPT NOCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZB|100017997|05/05/2010|priority 1 |Q1|BP|Unknown|BPTH IWOCS 4 earth strap corrosion|ATCO NOCO NOPT NOTE|BPTH IWOCS 4 earth strap corrosion|Damage |Damage from corrosion|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000037365|06/04/2009|priority 3 |Q3|PETROBRAS|GOM|Wrong configuration of manifold block|ATCO NOTE NOPT NOCO|Incorrect requirments in QN 200121418|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Specification error
ZF|P6000102687|22/04/2014|priority 3 |Q3|Unknown|Unknown|Possible gas leakage inside SCM|NOPT ATCO NOCO NOTE|Possible gas leakage in filling valve|Test Related |OBS-Leakage (gas)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000062990|15/01/2016|priority 3 |Q3|Unknown|Unknown|Water contamination found in SCM silicon|NOTE ATCO NOCO NOPT|Hose clamp not tigthen|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZD|P6000055605|14/03/2013|priority 3 |Q2|Unknown|Unknown|PT/TT Spare 7 not functioning on SCM 314|NOCO NOPT NOTE ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Vendor related |Assembly error
ZF|P6000029747|17/09/2010|priority 1 |Q3|ENGIE|NORTH SEA|Operational problems regarding SW|NOTE NOCO ATCO NOPT|In-house PRD updated with SIL SW info|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100051269|09/05/2017|priority 2 |Q1|Unknown|Unknown|Vigdis  Failure internally in SCM|NOPT NOTE ATCO NOCO|Mismatch between Y2 and TFMC SAP|Electrical |Component Failure|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 19|NOCO NOTE ATCO NOPT|Investigate Coupler Rotation-BPAT SCM 19|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZB|P6000063531|29/04/2017|priority 1 |Q1|Unknown|Unknown|Vigdis FD027 Sensor reading fault F1 SCM|OSTS NOPR NOTI|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000068912|02/02/2012|priority 3 |Q3|TOTAL|Unknown|Fiber outside acceptance criteria|ATCO NOPT NOTE NOCO|Fiber damaged during OC assembly|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|P6000101955|11/09/2014|priority 1 |Q1|Unknown|Unknown|Tyrihans Claim 265 SCM 03|NOCO NOTE ATCO|Change over valve leaking|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 26|ATCO NOPT NOTE NOCO|Investigate Coupler Rotation-BPAT SCM 26|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|100035118|15/05/2008|priority 2 |Q3|PETRONAS|Unknown|WOCM Shipped in Horizontal (Side)|ATCO NOTE NOPT NOCO|mis-interpretation|FMC Other Defect |Unknown|FKS Quality system issues|Product Realization|Other external causes |Unknown
ZF|100049000|04/05/2010|priority 3 |Q3|BP|GOM|Leaking Coupler|ATCO NOCO NOPT NOTE|Leaking Coupler|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Couplers|Hydraulic Coupler|FMC Test |Damaged during testing
ZF|P6000103208|12/05/2014|priority 3 |Q3|Unknown|Unknown|Test Error/Exxon/SCM/Exposed to Short|NOCO NOPT NOTE ATCO|Test Error|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|100049000|21/06/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 28|ATCO NOPT NOTE NOCO|Investigate Coupler Rotation -BPAT SCM28|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|100020278|15/05/2013|priority 4 |Q3|Unknown|Unknown|SCM improperly mounted to shipping skid|NOTE NOPT ATCO NOCO|DWG updated ref CM500000315835|Design |Drawing Error|SS - Controls - Test and Transportation|SCM Transport Skid|FMC Engineering related |Continuous Improvement
ZE|P6000105708|19/03/2014|priority 4 |Q3|Unknown|Unknown|No reading on EC3 pin 9 and 10|NOTE ATCO NOPT NOCO|Procedure (unclear) not followed|Test Related |OBS-Function|SS - Controls -SCM el/opt components|SCM Wiring|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000083428|24/10/2013|priority 3 |Q3|Unknown|Unknown|PT shows higher reading during FAT|NOTE NOCO ATCO NOPT|PT value increase during test|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000088626|06/03/2015|priority 2 |Q3|Unknown|Unknown|Mac Address plate wrong|ATCO NOCO NOPT NOTE|Nameplate copied from prev proj|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 05|ATCO NOCO NOPT NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|100067526|20/12/2018|priority 2 |Q1|Unknown|Unknown|Unable to get good pressure test of DHSV|NOTI NOPR OSTS|Test criteria was out of range for the s|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Test |Improper Set/Up
ZF|P7000039672|14/02/2014|priority 1 |Q3|Unknown|Unknown|Trafo sem marcação de alinhamento|NOPT NOTE ATCO NOCO|FMC KONGSBERG SUBSEA AS|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZD|P6000074156|13/03/2012|priority 3 |Q2|Unknown|Unknown|ATS-Missing Documentation|NOTE NOCO NOPT ATCO|DRL-0000020085  DRL-0000020034|Documentation |Missing Certificates / Records|Vendor Quality system issue|Quality Management System|Vendor related |Specification not followed
ZF|P6000074156|06/01/2013|priority 3 |Q3|Unknown|Unknown| Data plate information is incorrect.|ATCO NOCO NOTE|data plate information is incorrect|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|100017278|13/02/2013|priority 3 |Q3|Unknown|Unknown|Wrong path for alt.program SEM in doc.|NOCO NOTE ATCO|Wrong path for alt.program SEM in doc.|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000039844|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000068902|15/08/2011|priority 3 |Q3|TOTAL|Unknown|DHI values are unstable|NOTE NOCO ATCO NOPT|Simulator properties not adequate|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Test |Incorrect set up/testing
ZF|P6000028371|05/06/2008|priority 2 |Q3|Unknown|Unknown|Unlock Line Needs to be Moved|NOPT NOTE ATCO NOCO|Lock/Unlock Line Not in Correct Position|Procurement |Vendor did not complete required work|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Assembly error
ZF|P6000055605|27/12/2010|priority 2 |Q3|SHELL|GOM|CPU600 improving startup on long umbilic|NOTE NOCO ATCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZE|P7000039672|28/11/2016|priority 3 |Q3|PETROBRAS|Unknown|FNCR-2365-Leitura Flow Meter Retorno|NOTE NOCO NOPT ATCO|Setup de teste|Unknown|Unknown|Subsea Control Module (SCM) Electrical|Hydraulic flow meters|Test |Improper Set/Up
ZF|100052701|09/07/2013|priority 3 |Q3|Unknown|Unknown|SCM Tyrihans wrong SW versin delivered|NOTE NOPT ATCO NOCO|Procedures were missing information|Documentation |Incorrect user documentation (customer)|SS - Controls -Computer system software|Network config|FMC Engineering related |Engineering Error
ZE|100048038|20/10/2016|priority 2 |Q3|Unknown|Unknown|Repeating SCM compensator issues|ATCO NOTE NOPT NOCO|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Variance|Enhance Process
ZF|P7000016420|22/09/2011|priority 1 |Q3|Unknown|Unknown|sujeira no Manifold Block|NOCO NOPT ATCO NOTE|Bosch - manifold block|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|100056176|12/12/2013|priority 3 |Q3|Unknown|Unknown|V-CON Flowmeter test not performed|ATCO NOCO NOPT NOTE|Lack of CPI test Equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000104114|24/05/2017|priority 3 |Q3|Unknown|Unknown|Leakage on SRM with SN 10|ATCO NOCO NOTE NOPT|Leakage on SRM with SN 10|TEST |Leak|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Machine Shop Equipment |Machine Malfunction
ZF|P6000103208|14/11/2013|priority 4 |Q3|Unknown|Unknown|Piece of metal inside coupler|NOCO NOTE NOPT ATCO|Particle contamination found during test|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000069820|10/01/2012|priority 1 |Q3|CONOCOPHILLIPS|Unknown|(SS) MRM Software Version update|NOTE ATCO NOCO|MRM Software Version update|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000088604|25/02/2013|priority 3 |Q3|Unknown|Unknown|short circuits EC8:1 til EC9:1 and|NOTE NOPT NOCO ATCO|Wiring error by operator.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000100953|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|Unknown|(SS) MRM Software Version update|NOTE ATCO NOCO NOPT|MRM Software Bug Fix|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000147469|29/09/2017|priority 2 |Q3|Unknown|Unknown|Loose bolt found during Ph.C inspection|NOCO ATCO NOTE|Operator forgot to torque bolts|Assembly |UnderTorqued|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000039672|05/09/2018|priority 1 |Q3|Unknown|Unknown|ECN  7090703    PN  P7000017838|NOTE NOPT NOCO ATCO|Error-concept/calculation|Design |DBI Error|Object Types to Eng Matl CLASS|kits|FMC Engineering related |ECN Change
ZF|7105128|27/10/2015|priority Unknown|Q3|Unknown|Unknown|No spare bolts f/the top lid of the SCM|NOTE NOPT ATCO NOCO|Unknown|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Other mechanical components|QA/QS/QI Related|Documentation error
ZF|P6000104114|02/02/2018|priority 3 |Q3|TOTAL|Unknown|Broken connector pins|NOCO ATCO NOTE|Unknown|Damage |Damage during testing|Object Types to Eng Matl CLASS|srm_assy|Vendor related |Specification not followed
ZB|100020562|15/06/2009|priority 2 |Q1|BP|GOM|No readings for sensor sim on EC4(9:12)|NOPT ATCO NOTE NOCO|No readings for sensor sim on EC4(9:12)|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |No Non-Compliance
ZF|P6000067533|08/01/2013|priority 1 |Q3|Unknown|Unknown|SCM Modules stored outside with no PSM|NOCO NOTE ATCO|Improper Storage|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000088604|26/03/2015|priority 4 |Q3|Unknown|Unknown|(CDM)WST SCM #16-MRM Version discrepancy|ATCO NOTE NOCO|MRM Version discrepancy|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P6000088751|07/07/2014|priority 3 |Q3|Unknown|Unknown|GWF SCM#3 SEM A CPU IN SUSPEND MODE|NOCO ATCO NOTE NOPT| SEM - A CPU IN SUSPEND MODE.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100055600|18/04/2008|priority 3 |Q3|TALOS|GOM|damaged check valve on the HP return|NOPT ATCO NOCO NOTE|damaged check valve on test hose|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZB|100056443|02/02/2015|priority 3 |Q1|Unknown|Unknown|GC 274 ppp link on RIBT/RIBS (Vega)|NOCO ATCO NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000055605|10/04/2014|priority 4 |Q3|Unknown|Unknown|Break bolt flange|NOPT NOTE ATCO NOCO|Screw fracture inside adapter plate hole|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100020278|11/12/2009|priority 3 |Q3|EXXONMOBIL|Unknown|Megi Sea RIT procedure issues|NOPT NOTE ATCO NOCO|Megi Sea RIT procedure issues|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Procedure error
ZF|3794920|22/10/2015|priority 3 |Q3|Unknown|Unknown|Missing GA DWG and spare part info.|ATCO NOCO NOTE|Old parts not acc to today standard|Obsolescence Issue:&|Not Available|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Cause not found
ZE|P7000039672|10/08/2018|priority 2 |Q3|Unknown|Unknown|SCM - Leitura dos sensores externos|OSTS OSNO|Problema de leitura|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Electrical |Other- Specify in comments
ZF|P7000024191|15/08/2014|priority 1 |Q3|Unknown|Unknown|Communication Failure SEM B|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Intercompany|FMC Kongsberg
ZE|100017997|23/08/2010|priority 3 |Q3|Unknown|Unknown|SCM EC port corrosion|NOPT ATCO NOCO NOTE|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|3811810|24/02/2015|priority 2 |Q3|Unknown|Unknown|Incomplete BOM for PN 3811810|NOTE ATCO NOCO|Not transferred from Procim/Update SAP|Obsolescence Issue:&|Not Available|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100026328|16/11/2015|priority 3 |Q3|Unknown|Unknown|Loosen cabels inside the SEM|NOCO NOPT NOTE ATCO|Loose cables are fixed  supplier informe|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Manufacturing Engineer Erorr
ZB|P6000105542|12/08/2014|priority 2 |Q1|Unknown|Unknown|OSD2 Claim 001 SCM Router cards|NOTE NOCO ATCO|Wrong connector installed on XT|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Fabrication Shop Personnel |Operator error
ZF|P6000037215|13/04/2011|priority 2 |Q3|Unknown|Unknown|Alt prog not downloading correctly|NOPT NOCO NOTE|SW bug|Test Related |OBS-Function|SS - Controls - Electric Products|Other Electric Products|Vendor related |Programmer Error
ZF|P6000069056|08/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100017997|15/08/2012|priority 3 |Q3|Unknown|Unknown|BOM is incorrect|ATCO NOPT NOTE NOCO|Specification not followed|Documentation |Procedure / Process Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P7000001843|04/09/2015|priority 2 |Q3|PETROBRAS|Unknown|MMR - SCM does not reach vacuum|NOCO NOTE ATCO|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Assy |Damaged during assembly
ZF|P6000123495|18/02/2016|priority 3 |Q3|Unknown|Unknown|High internal leakage - control valves|NOCO ATCO NOPT NOTE|Too high leakage  all DCVs replaced.|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZB|100025661|12/06/2009|priority 2 |Q1|BP|GOM|F5 SCM 68 RAM Warning|ATCO NOCO NOTE NOPT|F5 SCM 68 RAM Warning|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor related |Equipment Malfunction
ZF|100056918|06/03/2008|priority 2 |Q3|WOODSIDE|Unknown|Replacement of DCV's|NOTE NOCO NOPT ATCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000073613|25/06/2013|priority 3 |Q3|Unknown|Unknown|IWCM send/recieve test error|NOCO NOTE ATCO NOPT|Wiring specification updated|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P6000098616|20/06/2013|priority 2 |Q3|Unknown|Unknown|HS CAN bus grounding error on CPU card|ATCO NOCO NOTE NOPT|ISO GND missed in wiring specification|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000088604|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE NOPT|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000058949|23/02/2011|priority 3 |Q3|Unknown|Unknown|Wrong wiring on outercan|ATCO NOTE NOCO NOPT|Wiring towards Outercan incorrect|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000031350|15/06/2009|priority 3 |Q3|GJØA|Unknown|Communication problems|NOPT NOTE NOCO ATCO|Error to be confirmed in QN200132018|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Unknown
ZF|100037965|21/01/2009|priority 1 |Q3|BP|Unknown|BPLOF: HC7 (CV-O) failled to operate|NOCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|P6000064909|21/10/2014|priority 2 |Q1|TOTAL|Unknown|Laggan Claim 089 - SCM#4|NOCO ATCO NOTE|Component failure|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Material error
ZF|P6000104115|15/05/2014|priority 3 |Q3|Unknown|Unknown|Error on baseplate on teststand|ATCO NOPT NOCO NOTE|Interface not verified towards SCM|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Engineering related |Engineering Error
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|ATCO NOCO NOTE NOPT|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000050867|06/01/2010|priority 3 |Q3|PETROBRAS|Unknown|DAS unit communication failure|NOTE NOPT ATCO NOCO|DAS unit communication failure|Test Related |OBS-Component Error|SS - Controls - Electric Products|Electrical Components|FMC Test |Missed operation
ZD|P6000104116|02/08/2016|priority 3 |Q2|Unknown|Unknown|DIU LOCK PIN MISALIGNMENT|NOCO ATCO NOTE|Dimensional Issue|Machining Related |OBS-Inside Diameter Error|SS - Compl. & W.Over - XT - General|Tree Frame|FMC Other causes/damage |QN Cancelled
ZF|P6000083428|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOPT ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100005667|19/06/2015|priority 3 |Q3|Unknown|Unknown|FSM Test in FAT not performed|ATCO NOPT NOTE NOCO|Test equipment unstable|Damage |Wear & Tear|SS - Controls -Instrumentation|Other SCM instruments|FMC Test |Missed operation
ZE|100051992|17/06/2015|priority 4 |Q3|Unknown|Unknown|(CDM)Leakage from silicone check valve|ATCO NOTE NOCO|Leakage from silicone check valve|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000043766|14/04/2010|priority 4 |Q3|PETROBRAS|Unknown|Nitrogen pre charge|ATCO NOCO NOTE|Nitrogen pre charge|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZF|P6000138867|11/10/2016|priority 3 |Q3|Unknown|Unknown|Loss of communication powerline|NOCO ATCO NOTE|Issues with SPCTU|TEST |Function|SS - Controls - Electronic Boards|Comm.link (Power line)|FMC Test |Tooling
ZE|P6000051036|03/08/2009|priority 3 |Q3|Unknown|Unknown|QA in Material Control process|ATCO NOCO NOPT NOTE|Process/Procedure Ineffective|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Causes for Improvement|Process/Procedure Ineffective
ZF|P7000016420|23/05/2011|priority 1 |Q3|Unknown|Unknown|Fios de conectores danificados|NOPT NOTE ATCO NOCO|Conector outer can Danificado|FMC Other Defect |Physical|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |Damage during transport
ZF|100049000|20/01/2016|priority 3 |Q3|Unknown|Unknown|BP Atlantis SCM 32 leakage testing:|NOTE NOCO NOPT ATCO|Leakage not identified  accepted as is|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |Cause not found
ZF|100054943|24/10/2011|priority 3 |Q3|Unknown|Unknown|Acceptance criteria not clearly stated|ATCO NOTE NOCO|Acceptance criteria in procedure are ok.|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P7000024900|28/03/2013|priority 1 |Q3|Unknown|Unknown|DCV danificada/manifold block danificado|NOPT ATCO NOCO NOTE|Danificado durante desmontagem|Danificado durante desmontagem||Assembly Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Operator Error
ZF|P6000079433|08/03/2012|priority 3 |Q3|CONOCOPHILLIPS|Unknown|SCM#3 SW download problems|ATCO NOPT NOTE NOCO|SCM#3 SW download problems.|Test Related |OBS-Wrong Test Procedure Used|SS - Controls -Computer system software|Basis 200e SW|FMC Engineering related |Procedure error
ZF|P6000076121|06/09/2011|priority 3 |Q3|CNOOC|Unknown|Outercan do not fit to the SCM|ATCO NOPT NOCO NOTE|FMC DWG not updated|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Engineering related |DWG Error
ZF|P7000024191|26/02/2013|priority 1 |Q3|Unknown|Unknown|Frequencia da SEM B fora do especificado|NOTE ATCO NOCO NOPT|Unknown|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Continuous Improvement
ZF|100020562|28/01/2010|priority 2 |Q3|Unknown|Unknown|BPTH ETU Projspec.dll for SKOFLO Changes|NOCO ATCO NOTE NOPT|BPTH ETU Projspec.dll for SKOFLO Changes|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZF|100066325|06/08/2012|priority 2 |Q3|Unknown|Unknown|Duplicate serial numbers created.|NOCO ATCO NOTE|Duplicat of excisting S/N in SAP|Assembly Related |OBS-Component TraceabilityNot Maintained|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZF|P6000088751|12/12/2012|priority 3 |Q3|Unknown|Unknown|Water inside SCM|NOPT NOTE NOCO ATCO|Leakage on SCM outercan|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZB|P6000067533|08/10/2014|priority 3 |Q1|Unknown|Unknown|Kirinskoye SCM 03 & 05 SUBSEA|NOCO NOTE ATCO|Hydraulic couples on base need change|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|Traceability Info Missing on BPTH SCM22|NOPT NOTE NOCO ATCO|Traceability Info Missing on BPTH SCM22|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P7000000897|10/01/2011|priority 1 |Q3|Unknown|Unknown|Camada de revestimento - Coating layer|NOPT NOCO NOTE ATCO|Unknown|Coating/Plating |Painting Defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Paintshop Related|Paint defect
ZE|P6000132097|05/11/2017|priority 3 |Q3|Unknown|Unknown|Lack of Silicon on SCM|NOPT NOCO ATCO NOTE|Customer choose not to mobilize EQ|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Documentation Requirement |Other- Specify in comments
ZF|P6000105542|08/01/2013|priority 4 |Q3|Unknown|Unknown|Deviation to TR1233  section  7.4.4|NOCO NOPT NOTE ATCO|Unknown|Change/Deviation Request |Conversion approval|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000028371|23/10/2008|priority 1 |Q3|SHELL|GOM|Manifoldblock missing in iBASElist|NOTE NOPT NOCO ATCO|error during transition from hand ibase|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Machine Shop Personnel |Lack of Training
ZF|100029062|07/09/2014|priority 1 |Q3|Unknown|Unknown|THI not identified|NOCO ATCO NOTE|Document is already linked in SAP|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000001621|23/08/2011|priority 1 |Q3|Unknown|Unknown|USINAGEM INCOMPLETA|NOCO ATCO NOPT NOTE|erro na usinagem FMC|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Operator Error
ZF|P6000126219|10/01/2018|priority 3 |Q3|Unknown|Unknown|Appo SCM incorrect SW version on DHI203|NOPT ATCO NOTE NOCO|TFMC Technician error|Software |Other- Specify in comments|Object Types to Eng Matl CLASS|scm_mkIIE|Software |Other- Specify in comments
ZF|P7000039672|30/09/2014|priority 1 |Q3|Unknown|Unknown|Adapter plate HP danificada|NOCO ATCO NOPT NOTE|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Damaged during assembly
ZF|P7000000897|01/02/2012|priority 1 |Q3|Unknown|Unknown|Ausencia de END no item|NOCO NOPT ATCO NOTE|DOG without NDE|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100035013|07/07/2009|priority 2 |Q3|SHELL|Unknown|Leakage on SCM|NOTE ATCO NOCO NOPT|Leakage|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Unknown
ZF|P7000008275|01/11/2012|priority 1 |Q3|Unknown|Unknown|Seguimentos da eletrônica TUM (tambaú#4)|NOCO NOPT ATCO NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|Intercompany|FMC Kongsberg
ZF|7101401|23/02/2017|priority 3 |Q3|PETROBRAS|Unknown|MMR - Damaged Stabs from Outer Can|NOTE ATCO NOPT NOCO|Error when placing Outer Can on pallet|Assembly |Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Paintshop Related|Operator error
ZF|P6000064910|26/03/2015|priority 3 |Q3|Unknown|Unknown|Product improvment|NOTE NOPT ATCO NOCO|Incorrect part in BOM/DBI|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZE|P6000122626|09/05/2016|priority 3 |Q3|Unknown|Unknown|Leakage test failed during FAT|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Test |Component Malfunction
ZF|P7000000897|10/11/2011|priority 1 |Q3|Unknown|Unknown|Used diferent ESPI Simulator|ATCO NOCO NOPT NOTE|Unknown|Test Related |OBS-Function|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|Other external causes |Customer Error/responsibility
ZF|P6000079984|20/09/2012|priority 1 |Q3|Unknown|Unknown|Strainer not isolated.|NOTE NOCO NOPT ATCO|GND strap in contact w/isolated strainer|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Assy |Operator Error
ZF|P7000016420|25/04/2011|priority 1 |Q3|Unknown|Unknown|Corr monitor|NOCO NOPT NOTE ATCO|Simulador CM não funciona|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Other external causes |Customer Error/responsibility
ZF|P7000016420|21/10/2010|priority 1 |Q3|Unknown|Unknown|Nut com interferência no canal do Dog.|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100068622|13/11/2012|priority 2 |Q3|Unknown|Unknown|CPU 151 RAM not upgraded|NOPT ATCO NOCO NOTE|No final inspection performed|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZF|100018082|17/08/2012|priority 2 |Q3|STATOIL|NORTH SEA|SCM03 Mikkel  damaged o-ring|NOPT NOCO NOTE ATCO|Loose bolts between M.block & Baseplate|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Baseplate|QA/QS/QI Related|Operator error
ZB|3801623|21/03/2013|priority 2 |Q1|Unknown|Unknown|Wrong instalation of SCM on Heidrun well|NOCO NOPT NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Damaged during installation
ZF|P6000055605|11/04/2011|priority 3 |Q3|Unknown|Unknown|Miscopy in Doc No: TST60053923  MAC addr|NOTE ATCO NOPT NOCO|Human mistake when writing TST60053923|Documentation |Procedure / Process Error|FKS Quality system issues|Quality Management System|FMC Engineering related |Procedure error
ZF|P6000122626|05/04/2016|priority 3 |Q3|Unknown|Unknown|Leakage test failed during FAT|ATCO NOTE NOPT NOCO|Returned to vendor for RCA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Engineering related |Engineering Error
ZF|7104033|18/03/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOPT ATCO NOCO NOTE|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZE|P6000105542|22/12/2014|priority 2 |Q3|Unknown|Unknown|SCM manifold block failure - SN 16|NOTE ATCO NOCO|See attached RCA|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZF|P6000058949|12/08/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong placement and marking of EC's|NOTE ATCO NOCO|DWG not checked or misread|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000108025|16/01/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000105542|27/11/2014|priority 1 |Q3|Unknown|Unknown|RV leaking on top of SCM|NOTE ATCO NOCO|SCM LEAKING RTV|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|100052701|16/04/2009|priority 2 |Q3|Unknown|Unknown|CANbus testing failed|ATCO NOCO NOTE NOPT|Error in external cables|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOCO NOPT NOTE|ECN 7058839 - P7000017839|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000000897|04/06/2010|priority 1 |Q3|Unknown|Unknown|PT-09 fail readings at BC-10 SCM 10.|ATCO NOCO NOPT NOTE|Sensor apresentando leituras flutuantes|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Harness|Vendor related |Equipment Malfunction
ZF|P6000105542|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000074156|17/06/2014|priority 4 |Q3|Unknown|Unknown|(CDM) Found silicone leak out from SCM|NOTE ATCO NOPT NOCO|Silicone leak out from SC|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZD|P6000079984|13/09/2012|priority 3 |Q2|Unknown|Unknown|Marks on baseplate mounted ECs|ATCO NOCO NOTE NOPT|Wrong angle on connector wing on SCMTS|Damage |Damage during testing|SS - Controls -SCM Test Stand|Other mechanical components|FMC Test |Damaged during testing
ZF|100055762|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|ATCO NOTE NOCO NOPT|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000037365|29/04/2009|priority 3 |Q3|PETROBRAS|GOM|Communication problems in hyperbaric|NOTE NOPT NOCO ATCO|USB to RS232 conv between Laptop&ETU-PC|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Incorrect set up/testing
ZF|P6000121958|16/04/2015|priority 3 |Q3|Unknown|Unknown|Insufficient capabilitites for SCM DCV's|NOPT NOTE ATCO NOCO|DCV was qualified for the project y.2000|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Other causes/damage |No Non-Compliance
ZF|P6000064911|12/09/2017|priority 1 |Q3|Unknown|Unknown|Cust. Con. - Shipping with open S3's|NOPT NOCO NOTE ATCO|Unknown|Project|Project Requested Unfinished shipment|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Planning error
ZE|P6000091085|12/10/2015|priority 1 |Q3|Unknown|Unknown|(N) - OWIRS Deadman sequence|NOPT NOCO ATCO NOTE|Unknown|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Documentation
ZF|P7000016420|25/01/2011|priority 2 |Q3|Unknown|Unknown|Peça danificada|ATCO NOTE NOPT NOCO|Unknown|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000069056|11/11/2011|priority 3 |Q3|Unknown|Unknown|Missing HC61 on hyberbaric camber 3|ATCO NOCO NOTE|Hyp. chamber missing return line HC61|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000079433|09/11/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Possible chips inside the HP-Config Plug|NOCO ATCO NOTE NOPT|Plugs not cleaned by supplier.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZF|P6000104115|04/06/2014|priority 4 |Q3|Unknown|Unknown|Attenuiation in fiberpenetrator|NOTE NOCO ATCO NOPT|Improper fiber splice bracket/box design|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|Other el/opt components|FMC Engineering related |Engineering Error
ZF|P6000064909|01/06/2011|priority 3 |Q3|TOTAL|Unknown|Wiring error in SEM|ATCO NOCO NOTE NOPT|Delayed procedure & spec. update|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Harness|FMC Engineering related |Specification error
ZF|100034629|16/10/2014|priority 1 |Q3|OVERALL PROJECT ROLL-UP OSEB.VESTFLANKEN|Unknown|Oseberg 23 silicone in SEM A|NOCO ATCO NOTE|Seacon optical penetrator issue|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Design Error
ZF|P6000065886|16/12/2010|priority 2 |Q3|Unknown|Unknown|Varous issues BOM and DWG|NOTE ATCO NOCO|Various BOM and DWG incorrect|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Engineering related |DWG Error
ZF|7101172|24/03/2015|priority 2 |Q3|Unknown|Unknown|Crude oil and gas inside the SCM|ATCO NOTE NOCO|Cause for leakage not found yet|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000068918|05/07/2011|priority 3 |Q3|Unknown|Unknown|Wiring fault at PT1 A and B|NOCO NOTE NOPT|Human opr failure at SCM wiring|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100033987|12/11/2008|priority 1 |Q1|STATOIL|NORTH SEA|WARRANTY CLAIM 170 Same as QN 200091091|ATCO NOCO NOPT NOTE|Unknown|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Materials/Stores related |Operator Error
ZF|P6000116166|02/06/2016|priority 4 |Q3|TULLOW|WEST AFRICA|LP DCVs Leak Test Failure|NOCO DLFL|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100020562|09/05/2012|priority 4 |Q3|BP|GOM|Incorrect workscope|ATCO NOPT NOTE NOCO|Incorrect workscope|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Damage from Wear and Tear
ZB|P6000105542|30/10/2015|priority 1 |Q1|Unknown|Unknown|Gullfaks GSO 287 Pressure gauge SUBSEA|NOTI OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000055605|20/09/2013|priority 3 |Q3|Unknown|Unknown|Child QN for SCM # 320 SPFM comms issues|NOCO ATCO NOPT NOTE|SPFM Comms Issues|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Lack of Training
ZD|100025661|01/02/2012|priority 3 |Q2|MARUBENI|GOM|PT 22 SHOWING WRONG VALUES|NOTE NOCO ATCO NOPT|PT22 Showing Wrong Values|Test Related |OBS-Function|SS - Controls - Topside Products|Subsea Control Unit (SCU)|FMC Test |Incorrect set up/testing
ZF|P6000083428|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000037215|05/05/2011|priority 3 |Q3|GJØA|Unknown|Photos Background needed in the workshop|NOPT ATCO NOTE NOCO|Bad photo area|Unknown|Unknown|SS - Controls - Electric Products|Other Electric Products|QA/QS/QI Related|Final Inspection error
ZF|P6000076121|28/11/2011|priority 2 |Q3|CNOOC|Unknown|(SS) Wrong check valve cap for SCM.|NOCO NOPT NOTE ATCO| Wrong check valve cap for SCM|Design |Specification Error|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Wrong Part Delivered
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOPT ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZE|100029062|09/03/2009|priority 3 |Q3|TOTAL|Unknown|BOM needs update|NOCO ATCO NOTE NOPT|Update of voided PN with new PN|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Causes for Improvement|Documentation
ZF|P7000024191|02/08/2012|priority 1 |Q3|Unknown|Unknown|SEM A CAN BUS interface 3  out of order.|NOCO ATCO NOTE NOPT|||Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SCM (all types of Control Modules)|FMC Test |FMC Kongsberg
ZF|P6000077638|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO NOTE ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000008275|16/11/2012|priority 1 |Q3|Unknown|Unknown|Protection ring Ovalizada|NOCO ATCO NOPT NOTE|Peça ovalizada|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Design Error
ZF|P6000132097|30/03/2017|priority 4 |Q3|Unknown|Unknown|HP2 PT showing incorrect value in EFAT|NOCO NOTE ATCO|SCM return to MMR for service.|TEST |Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|FMC Other causes/damage |Cause not found
ZF|P7000000897|16/01/2012|priority 1 |Q3|Unknown|Unknown|El. Connector with backshell broken|ATCO NOPT NOTE NOCO|Equipamento retornou do campo|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |Damage from Wear and Tear
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 06|NOTE NOCO NOPT ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100025661|16/11/2011|priority 2 |Q3|Unknown|Unknown|Wiring mistake on COV HP|NOPT NOCO ATCO NOTE|Wiring error. Procedure needed update.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Engineering related |Procedure error
ZF|P7000002082|05/07/2012|priority 1 |Q3|Unknown|Unknown|Sensores analógicos inoperantes|NOCO NOPT ATCO NOTE|SCM MMR|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|Other external causes |Customer Error/responsibility
ZF|100001156|30/07/2015|priority 2 |Q3|Unknown|Unknown|HFT omit from mobilisation of SCM|ATCO NOCO NOTE NOPT|HFT omit from mobilisation of SCM|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|100067526|24/09/2012|priority 1 |Q3|STATOIL|NORTH SEA|Filter line LP2 has been scratched up|NOTE ATCO NOPT NOCO|Filter line LP2 in m.block  scratched up|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Cause not found
ZF|P6000080343|09/11/2011|priority 3 |Q3|TULLOW|WEST AFRICA|Possible chips in HP-Config Plug in SCM.|NOTE NOCO NOPT ATCO|Plugs not cleaned by supplier.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Fittings|Vendor related |Specification not followed
ZF|P6000116166|01/06/2015|priority 3 |Q3|Unknown|Unknown|Screw do not fit on EC adapter.|ATCO NOPT NOCO NOTE|Not investigated  scrapped|Machining Related |OBS-Ring Groove Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P7000024900|05/06/2013|priority 1 |Q3|Unknown|Unknown|PLUG FOR FILTER Danificado|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000104116|07/05/2015|priority 3 |Q3|Unknown|Unknown|M6x20 screw is to short|NOTE ATCO NOPT NOCO|One of the screws with incorrect length|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Materials/Stores related |Improper Packaging & Storage
ZF|3794920|12/05/2010|priority 3 |Q3|STATOIL|NORTH SEA|No information on internal leakage|ATCO NOCO NOTE|Missing information from Company|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZE|100035118|10/11/2016|priority 2 |Q3|WOODSIDE|Unknown|High return pressure on HP|NOTE ATCO NOCO|Continuously improvement of user doc's|TEST |Damaged During Testing|SS - Controls -SCM  hyd/mech components|Control Valve|Causes for Improvement|Documentation
ZF|7103382|16/12/2011|priority 2 |Q3|Unknown|Unknown|Hp filter blocked by unindentifyed greas|ATCO NOCO NOTE|SCM contaminated  crude oil?|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|7104670|06/02/2015|priority 3 |Q3|Unknown|Unknown|Concession_FSM Test in HFT not performed|NOTE NOCO ATCO NOPT|Test equipment not available|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZE|P6000088614|23/09/2015|priority 2 |Q3|Unknown|Unknown|HFT evaluation|NOPT NOTE NOCO ATCO|procedure confirmed ok by eng.kbg|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZE|P6000069056|26/10/2012|priority 1 |Q3|STATOIL|NORTH SEA|High pressure on return line|ATCO NOTE NOCO NOPT|Incorrect assembly by operator|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000055605|08/09/2011|priority 3 |Q3|SHELL|GOM|Fått feil deler fra lager|NOPT NOCO ATCO NOTE|Incorrect picking from stock by operator|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZF|100035013|03/02/2009|priority 3 |Q3|SHELL|Unknown|Brayco - transaqua mixed in hyperbaric|NOCO NOTE NOPT ATCO|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P7000024191|11/07/2012|priority 1 |Q3|Unknown|Unknown|Aterramento Não Conforme|ATCO NOPT NOCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000031350|22/10/2009|priority 1 |Q3|GJØA|Unknown|IWIS kommunikasjon problem!|NOTE NOCO NOPT|Wrong software revision.|Documentation |Incorrect Certificates / Records|SS - Controls -Instrumentation|Other SCM instruments|FMC Test |Incorrect set up/testing
ZF|P7000016420|04/07/2011|priority 1 |Q3|PETROBRAS|Unknown|No replies on BooTP Call Table.|ATCO NOTE NOCO NOPT|cause not  found|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Test |Incorrect set up/testing
ZF|P6000108469|28/01/2014|priority 4 |Q3|Unknown|Unknown|Solatron SPFM simulator has odd behavior|ATCO NOCO NOTE NOPT| Continuous Improvement|Test Related |OBS-Function|SS - Controls -Instrumentation|Singlephase Flow Meter|FMC Engineering related |Continuous Improvement
ZF|P7000016420|17/05/2011|priority 1 |Q3|Unknown|Unknown|Conector J4 da placa TIF SEM B|NOCO ATCO NOPT NOTE|Dano Parafuso TIF|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Assy |Damaged during assembly
ZF|100031223|08/09/2010|priority 3 |Q3|Unknown|Unknown|Document not linked to material|NOTE NOCO NOPT ATCO|Document not linked to part|Documentation |Procedure / Process Error|SS - Controls -Computer system software|150/615 SW|FMC Engineering related |ECN Error
ZF|P6000100953|03/12/2013|priority 3 |Q3|Unknown|Unknown|Measured 0Volt on EC2 pin 9 and 10|NOCO ATCO NOTE NOPT|Step in procedure missing  wiring error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000104116|12/11/2014|priority 3 |Q3|Unknown|Unknown|Scratch on o-ring surface  DIU13|NOCO NOPT NOTE ATCO|Damage due to packaging|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|SEM Can|Vendor related |Packaging/Handling
ZF|P7000039672|16/07/2013|priority 1 |Q3|Unknown|Unknown|Vazamento no Manifold block|NOCO NOPT NOTE ATCO|123643 - BOSCH REXROTH LTDA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZF|P6000063632|10/02/2011|priority 2 |Q3|Unknown|Unknown|gas leak test not acording to LWI|NOCO NOTE ATCO|Gas testing pressure reduced - HSE issue|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|7103233|20/10/2011|priority 2 |Q3|OVERALL PROJECT ROLL-UP|Unknown|Spring pin on locking mech broken.|ATCO NOTE NOCO|Share pin broken during handling.|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Cause not found
ZF|100052388|06/09/2012|priority 1 |Q3|Unknown|Unknown|Mobilization not according to recom.|ATCO NOTE NOPT NOCO|No choke bridge avlb. for FM test|Test Related |OBS-Test Omitted|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Tooling
ZF|P6000058949|11/02/2013|priority 4 |Q3|Unknown|Unknown|SCM not mobilized acc to PSM|NOCO NOTE NOPT ATCO|Customer Error/responsibility|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000039672|08/03/2016|priority 1 |Q3|Unknown|Unknown|Oxidação nos Dog's|NOCO ATCO NOTE NOPT|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Coating Defect
ZF|100018531|05/12/2016|priority 3 |Q3|SHELL|Unknown|MMR - EC4 Assembly without O-ring|ATCO|Technician did not followed assy proced|Assembly |Missing Components|SS - Controls -SCM el/opt components|El. Connector|Assembly |Procedures not Followed
ZB|P6000101955|07/10/2014|priority 1 |Q1|Unknown|Unknown|Tyrihans claim SPS250-001 SCM 01|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|100017997|05/03/2010|priority 1 |Q1|Unknown|Unknown|BPTH IWOCS Outer Can Repair|NOPT NOTE ATCO NOCO|Roughness out of tol. on ED int. seal|Raw Material |OBS-Hardness out of tolerance|WOCS Control Module (WOCM) Mech. w/MB|Outer can|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000069056|22/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|SCM - communication with SEM A router|NOPT ATCO NOCO NOTE|Follow-up in QN 200276026|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P1000018406|06/04/2009|priority 4 |Q3|Unknown|Unknown|Over-torque Of Outer Can|NOCO NOTE NOPT ATCO|Over-torque Of Outer Can|Damage |Damage during assembly|SS - Controls - Sensors|SCM Flowmeter|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000043714|05/07/2010|priority 2 |Q3|PETROBRAS|GOM|Change hydraulic coupler|NOCO NOPT ATCO NOTE|Sharp edge on Male coupler   test equip.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZF|P6000090632|21/06/2013|priority 3 |Q3|Unknown|Unknown|Signature curves not stable|NOTE ATCO NOPT NOCO|Wrong flow restrictors listed in BOM|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000121393|14/09/2015|priority 3 |Q3|Unknown|Unknown|Suspecting 960 bar at supply lines.|NOCO ATCO NOTE NOPT|Return pressure not monitored during hb|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P6000029772|21/06/2013|priority 2 |Q3|Unknown|Unknown|Non functional SRM|ATCO NOCO NOTE|Specification error|Test Related |OBS-Missed Operation|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Specification error
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|Unknown|Wrong Bill Of Material and wrong parts|NOTE NOCO NOPT ATCO|Coupler Interface on m.block (spc error)|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Engineering related |Specification error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOCO ATCO NOPT NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100056261|05/03/2009|priority 3 |Q3|MURPHY|WEST AFRICA|SCM- MURPHY AZURITE-LP SUPPLY FLOW METER|ATCO NOPT NOTE NOCO|LP SUPPLY FLOW METER|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|P6000042969|25/11/2010|priority 2 |Q3|Unknown|Unknown|Feil plukk av hydralic  plug hex hea|NOCO NOTE ATCO NOPT|Wrong amount picked in warehouse|FMC Other Defect |Part Lost|SS - Controls -SCMMB|Other hydraulic components|Intercompany|FMC Kongsberg
ZF|P6000039844|29/09/2009|priority 1 |Q3|SHELL|Unknown|Nitrogen leakage|NOCO NOPT NOTE ATCO|Tube was not tightened sufficiently duri|Test Related |OBS-Leakage (gas)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000042970|03/11/2009|priority 3 |Q3|TOTAL|WEST AFRICA|Unstable PT readings|NOCO NOPT NOTE ATCO|Wrong configuration of  Sensor sim.|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Test |Incorrect set up/testing
ZF|P7000001621|02/08/2010|priority 1 |Q3|Unknown|Unknown|Top Cover Hercules SN 03|ATCO NOTE NOPT NOCO|Furação em desacordo|Welding related |Structural Dimensional Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Design Error
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|Class 1 ECN 6083510|ATCO NOTE NOCO NOPT|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000024191|18/12/2012|priority 1 |Q3|Unknown|Unknown|Perda de comunicação Global 13 SN-13 B|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Function|SS - Controls - Electronic Boards|Power units|FMC Other causes/damage |Cause not found
ZF|P6000121393|31/01/2017|priority 3 |Q3|Unknown|Unknown|Missing Hyperbaric Test|NOTE NOCO NOPT ATCO|TST60110167 lost when creating MRB|FMC Other Defect |Part Lost|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Engineering related |Engineering Error
ZB|100067526|13/09/2017|priority 2 |Q1|Unknown|Unknown|SCM Fault reading value (Gullfaks)|NOCO NOTE ATCO|Improper job preparation|Assembly |Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Service Related:|Improper job preparation
ZF|100034440|30/11/2010|priority 2 |Q3|NYTT KONTROLLSYSTEM|Unknown|Class 1 ECN 6083510|NOCO ATCO NOTE NOPT|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|06/02/2017|priority 1 |Q3|Unknown|Unknown|SCM - FALHA NA LEITURA DO FLOWMETER|NOTE NOCO NOPT ATCO|Unknown|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Equipment Malfunction
ZB|100036936|13/11/2012|priority 2 |Q1|Unknown|Unknown|Ingen kommunikasjon med SCM pga feil spe|NOPT ATCO NOTE NOCO|FMC does not review well program|FMC Other Defect |Functional|Customer Compliant|Unsatisfactory Customer Satisfaction|Other external causes |Customer Error/responsibility
ZF|100020562|06/10/2009|priority 2 |Q3|BP|GOM|Water in module after hyperbaric test.|NOTE NOCO NOPT ATCO|Operator error  see QNR/Disposition|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P6000069056|30/08/2011|priority 2 |Q3|Unknown|Unknown|SCM – ROV visibility of HP return port|NOPT ATCO NOTE NOCO|ROV visibility in HP return port SCM|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000149536|24/05/2018|priority 1 |Q3|Unknown|Unknown|Int.Dev. - No MOB Carried Out on SCM|NOCO ATCO NOTE|Unknown|Change/Deviation Request |Process substitution request|Object Types to Eng Matl CLASS|scm_assy|FMC Other causes/damage |Planning error
ZD|P7000000897|19/06/2012|priority 1 |Q2|SHELL|Unknown|SEM B communication failure|NOPT ATCO NOCO NOTE|defect during function test|Test Related |OBS-Function|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|P6000069820|06/01/2012|priority 2 |Q3|CONOCOPHILLIPS|Unknown|(SS) MRM Software Version update|NOPT NOTE NOCO ATCO|MRM Software Bug Fix|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|P6000063531|27/04/2017|priority 1 |Q1|Unknown|Unknown|Worn silicone compensator bladder|NOCO ATCO NOTE|Unknown|Damage |Wear & Tear|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|P6000107981|30/10/2013|priority 3 |Q3|Unknown|Unknown|Black Outer Can marking Lines Fading|NOPT NOCO ATCO NOTE|Paint lines faded after hyperbaric|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|P7000039672|04/01/2016|priority 1 |Q3|Unknown|Unknown|ANOMALIA NA COLORAÇÃO DAS ADAPTERS PLATE|NOPT NOTE NOCO ATCO||||Welding related |Material Defect|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Material error
ZF|P6000083428|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|ATCO NOCO NOTE|SCM outercan drawing error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|2006 Shell Std SCM Restrictor Change|NOCO NOPT NOTE ATCO|2006 Shell Std SCM Restrictor Change|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000064909|08/06/2012|priority 4 |Q3|TOTAL|NORTH SEA|We did not get communicaton with the SCM|ATCO NOCO NOTE|Network not in default mode|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZB|100020278|29/10/2009|priority 2 |Q1|EXXONMOBIL|Unknown|09-MEGI-035 SS-W3 AWV PT failed/shorted|ATCO NOCO NOTE|09-MEGI-035 SS-W3 AWV PT failed/shorted|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZB|P7000039672|15/11/2013|priority 3 |Q1|Unknown|Unknown|Presalt Claim 001 SEM #12|NOTE ATCO NOCO|Defectiive comp. not trapped in test|Test Related |OBS-Function|SS - Controls - Electronic Boards|Main boards  CPU & I/O|Vendor related |Second tier supplier issue
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM PXT 04|NOPT NOTE NOCO ATCO|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000104111|20/09/2017|priority 3 |Q3|Unknown|Unknown|Child QN on defective SCM-P17|NOPT NOTE NOCO ATCO|Unknown|Damage |Damage during testing|Object Types to Eng Matl CLASS|scm_mkIII|Test |Other- Specify in comments
ZF|P7000008275|15/02/2012|priority 1 |Q3|Unknown|Unknown|Oxidação na Outercan|NOTE NOPT ATCO NOCO||||Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Damage from Wear and Tear
ZD|P6000080343|15/02/2012|priority 3 |Q2|Unknown|Unknown|ATS-Missing Documentation|ATCO NOCO NOTE NOPT|Missing required documentation|Documentation |Missing Certificates / Records|Vendor Quality system issue|Quality Management System|Vendor related |Specification not followed
ZF|7104033|18/02/2014|priority 3 |Q3|STATOIL|NORTH SEA|Operated DCVs with too high pressure|NOCO NOTE ATCO|Operator did not follow procedure.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZD|100056261|25/06/2008|priority 3 |Q2|Unknown|Unknown|no DBI referenced|ATCO NOPT NOTE NOCO|No DBI for part number|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZE|P6000074156|28/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM)Prellude-to blank out the ESRS|NOTE NOPT ATCO NOCO|Prellude-to blank out the ESRS|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|7104670|10/04/2014|priority 4 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOCO NOPT NOTE ATCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|3812476|28/02/2018|priority Unknown|Q3|Unknown|Unknown|Process not followed during PONC work|NOTE ATCO NOCO|QA not informed|Assembly |Other- Specify in comments|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Assembly |Other- Specify in comments
ZF|P6000093498|13/10/2015|priority 3 |Q3|Unknown|Unknown|WOCM -Fail to connect BMU-1A to consumer|ATCO NOCO NOTE|Software causing component failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE ATCO NOPT NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|NOTE NOCO NOPT ATCO|BOM incorrect.M6 A4-80 to M6 inconell718|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZF|P6000084906|24/03/2015|priority 3 |Q3|Unknown|Unknown|Unknown|NOPT ATCO NOTE NOCO|Picked wrong PT in warehouse|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|P6000104112|10/03/2015|priority 2 |Q3|Unknown|Unknown|Name plate has wrong max VAC|NOCO ATCO NOTE|Engineering error  marking on name plate|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000042968|01/09/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Damage to surface coating|ATCO NOCO NOPT NOTE|Storage handling of SCMs at Workshop|Coating/Plating |Painting Defect|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Improper handling
ZB|100067526|19/01/2016|priority 2 |Q1|Unknown|Unknown|SCM - leakage|NOCO NOPT ATCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOCO NOPT ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000068902|20/08/2013|priority 3 |Q3|Unknown|Unknown|PT 23 failed during EE test|ATCO NOCO NOTE NOPT|Unstable readings from PT.|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000102554|23/01/2014|priority 4 |Q3|Unknown|Unknown|Error in ELD60095678 TX/RX signal swappe|NOTE ATCO NOPT NOCO|Wiring spec. error in ELD60095678|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZB|P6000042969|31/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|Punch List SCM IXT 17|NOPT ATCO NOCO NOTE|Software improvement/correction|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100049392|05/03/2014|priority 3 |Q3|Unknown|Unknown|Missing GA DWG for SCM SYGNA|NOTE NOCO NOPT ATCO|Missing GA DWG for SCM SYGNA|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOTE NOCO NOPT ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|7101172|04/10/2012|priority 3 |Q3|Unknown|Unknown|Machining of sealing areas|NOCO NOTE ATCO ORAS|Corrosion on sealing area for EC on OC|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Materials/Stores related |Damage Due to Corrosion
ZF|P7000001843|10/01/2012|priority 2 |Q3|Unknown|Unknown|Problemas com o simulador PDG|ATCO NOTE NOCO NOPT|Unknown|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|P6000093501|19/11/2012|priority 3 |Q3|Unknown|Unknown|PT smart retur is not in the config|ATCO NOCO NOTE NOPT|No errors in the config|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Test |Incorrect set up/testing
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #8 Wiring|ATCO NOCO NOPT NOTE|BPTH SKOFLO SCM SN #8 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P7000008275|06/07/2012|priority 1 |Q3|Unknown|Unknown|Alteração nos valores de DEMEG.|NOTE NOPT NOCO ATCO|Simulador danificado|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000039672|06/09/2013|priority 1 |Q3|Unknown|Unknown|Outer Can does not mount|ATCO NOCO NOTE NOPT|101545 - KRISTIANSANDS SKRUEFABRIKK &|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Final Inspection Error
ZF|P6000042968|17/08/2009|priority 3 |Q3|TOTAL|WEST AFRICA|penetrator protection ring not in place|NOCO NOPT NOTE|Error to be confirmed in QN200136757|Assembly Related |Unknown|SS - Controls - Electronic Boards|Other Eletronic Boards|Vendor related |Unknown
ZF|100025661|23/06/2010|priority 2 |Q3|SHELL|GOM|Missing sign offs & Variance in book|NOTE NOCO ATCO NOPT|Intercompany process differences|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Houston
ZB|100048038|26/05/2010|priority 3 |Q1|CHEVRON|Unknown|Agbami SCM SN 6 LP flowmeter not working|ATCO NOTE NOCO|Agbami SCM SN 6 LP flowmeter not working|Raw Material |OBS-Defects in material|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Assy |Damaged during assembly
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #3 Wiring|NOCO NOPT NOTE ATCO|BPTH SKOFLO SCM SN #3 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000147469|28/11/2017|priority 1 |Q3|Unknown|Unknown|QUALITY ISSUE|NOTE ATCO NOCO|Unknown|Coating/Plating |Painting Defect|Object Types to Eng Matl CLASS|scm_assy|Vendor related |Coating Defect
ZF|P6000083428|04/10/2013|priority 3 |Q3|Unknown|Unknown|CPU 24v drop|ATCO NOTE NOPT NOCO|Bad wire connection > now corredted|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZF|100035013|08/07/2014|priority 2 |Q3|Unknown|Unknown|Silicone inside both SEM A and B|ATCO NOCO NOTE NOPT|Optical penetrator leaking|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P7000020444|25/06/2012|priority 1 |Q3|Unknown|Unknown|Rosca dos Conectores Ruim|NOPT ATCO NOCO NOTE||ODI|Assembly Related |OBS-Interface issue|SS - Controls -SCM el/opt components|Baseplate|Vendor related |Packaging/Handling
ZF|P6000080343|20/12/2011|priority 3 |Q3|Unknown|Unknown|Wrong El cans was mounted|NOPT ATCO NOTE NOCO|Picking error at warehouse|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -SCM  hyd/mech components|SEM Can|FMC Materials/Stores related |Operator Error
ZF|P7000024191|04/02/2013|priority 1 |Q3|Unknown|Unknown|Valores do DPT da SEM B fora do critério|NOCO ATCO NOPT NOTE|Erro no critério do Procedimento|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P7000039672|26/06/2014|priority 1 |Q3|Unknown|Unknown|Falta do Parafuso|ATCO NOTE NOPT NOCO|Unknown|FMC Other Defect |Part Lost|Common/Misc - Fasteners - Metric|Bolt|FMC Other causes/damage |Damage during transport
ZB|100035013|11/11/2009|priority 1 |Q1|SHELL|Unknown|SUBSEA-Ormen Lange  Claim 026 SEMB |ATCO NOCO NOPT NOTE|Power supply is damaged on SEM B|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |Cause not found
ZB|100052701|22/03/2010|priority 2 |Q1|STATOIL|NORTH SEA|Guarantee claim TYR SCM Well A4|ATCO NOTE NOCO|Solder debris on CPU and other cards|FMC Other Defect |Functional|Customer Compliant|Noncompliance to Customer Requirement|Vendor related |Material error
ZB|7104670|06/05/2008|priority 4 |Q1|Unknown|Unknown|Guarantee claim 127 - Failed SCM|NOTE NOCO ATCO|Unknown reason for failure|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100017997|30/11/2011|priority 3 |Q3|Unknown|Unknown|Procedure issue( Hft 10029374) HC-1616|NOCO ATCO NOTE|Procedure issue( Hft 10029374)|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000068918|13/10/2011|priority 2 |Q3|Unknown|Unknown|Delivery from Bandak Notodden AS.|NOCO NOTE ATCO|Doc not released and missing final insp.|Documentation |Missing Certificates / Records|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Planning error
ZF|100035014|19/04/2018|priority 3 |Q3|Unknown|Unknown|Company decided to not upgrade el.boards|OSNO NOPT|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZE|P6000093498|30/11/2015|priority 4 |Q3|Unknown|Unknown|LLP WOCM Communication Failure|NOCO ATCO NOTE|Error on SUPS SW  repair in SN300525765|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000104116|24/03/2014|priority 3 |Q3|Unknown|Unknown|Part not according to drawing|NOTE NOPT NOCO ATCO|See CRB for info  DRM60111600|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000083428|23/07/2012|priority 3 |Q3|Unknown|Unknown|GA drawing DU600060362/B needs update|NOPT ATCO NOCO NOTE|GA drawing DU600060362/B needs update|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|Other external causes |Customer Error/responsibility
ZB|100020562|25/11/2008|priority 2 |Q1|BP|GOM|Gas discharge from SCM|NOTE ATCO NOCO NOPT|Gas discharge from SCM|Test Related |OBS-Leakage (gas)|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Cause not found
ZF|100052701|26/08/2009|priority 3 |Q3|STATOIL|NORTH SEA|Internal leakage in HP function valve|NOPT NOTE ATCO NOCO|Internal leakage in HP function valve s|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZE|100066325|13/12/2012|priority 3 |Q3|Unknown|Unknown|Duplicate serial numbers created.|NOTE NOCO ATCO NOPT|Guidelines to be checked|Assembly Related |OBS-Component TraceabilityNot Maintained|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P6000116166|20/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|NOCO ATCO NOTE NOPT|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZB|100056176|29/10/2009|priority 3 |Q1|STATOIL|NORTH SEA|DHI119 ÅsgB R-1H  comm probl w/ETU|NOPT NOTE NOCO ATCO|Related to implementation of new equipm.|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Unknown
ZF|3787101|21/09/2009|priority 3 |Q3|Unknown|Unknown|External leakage control valve|NOPT NOCO NOTE ATCO|Holes for namepl drilled into hydr. line|Test Related |OBS-Leakage (Fluid)|SS - Controls - SS Control Module (SCM)|Hydraulic Valves|Vendor related |Unknown
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 5 RCA Actions_2 from RPT10033107|NOTE ATCO NOCO NOPT|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of Resources
ZD|100052231|20/07/2010|priority 3 |Q2|Unknown|Unknown|NO DBI/ACCEPTANCE CRITERIA|NOCO ATCO NOPT NOTE|NO DBI/ACCEPTANCE CRITERIA|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Intercompany|FMC Kongsberg
ZE|100037965|23/02/2015|priority 3 |Q3|Unknown|Unknown|inconsistent valve signature|NOCO NOTE ATCO|PRD updated  ref CM 500000338425.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZB|P7000001843|15/03/2012|priority 1 |Q1|PETROBRAS|Unknown|Interrompida instalação do SCM NS 02 MXL|NOTE NOCO NOPT ATCO|Unknown|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000109984|07/05/2014|priority 3 |Q3|Unknown|Unknown|oc not fit in outer can|NOTE NOPT NOCO ATCO|Shallow O.C. interface followup200381445|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000058949|14/02/2011|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|NOCO NOPT NOTE ATCO|SCM outercan drawing error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P7000001621|05/12/2011|priority 2 |Q3|Unknown|Unknown|Fixação não adequada.|NOPT ATCO NOCO NOTE|decorrente do processo de reparo|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|SKOFLO SCM SN #2 Wiring|NOCO NOPT NOTE ATCO|SKOFLO SCM SN #2  Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #11 Wiring|NOCO ATCO NOTE NOPT|BPTH SKOFLO SCM SN #11 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|100006609|17/05/2013|priority 1 |Q3|Unknown|Unknown|furação da hose house|NOCO ATCO NOTE NOPT|SCM MMR|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000031350|18/12/2013|priority 2 |Q3|Unknown|Unknown|Traceability issue|ATCO NOCO NOTE|Pick list error  correct in SAP traceabi|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Operator Error
ZF|P6000064910|30/05/2011|priority 2 |Q3|TOTAL|NORTH SEA|Power line error  GND error  => HSE risk|NOTE NOCO ATCO NOPT|Wrong assembly of transformer|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000050867|28/10/2009|priority 3 |Q3|PETROBRAS|GOM|Cascade DAS battery failure|NOTE NOPT ATCO NOCO|Cascade DAS battery failure|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Components|Vendor related |Equipment Malfunction
ZB|P6000029772|10/09/2012|priority 2 |Q1|Unknown|Unknown|Gjøa Claim 056 SRM 10|NOTE ATCO NOCO|Fibreoptical penetrator incorrectly ass.|Damage |Damage during assembly|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Assembly error
ZF|P7000008275|24/01/2012|priority 1 |Q3|Unknown|Unknown|LP Change over valve internal leakage.|NOTE NOPT ATCO NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000104112|05/11/2014|priority 3 |Q3|Unknown|Unknown|PT53 is not working proparly.|NOPT NOTE NOCO ATCO|Wrong values from PT  follow-up200411903|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Equipment Malfunction
ZF|P6000079984|27/06/2012|priority 3 |Q3|Unknown|Unknown|Marks on baseplate mounted ECs|ATCO NOPT NOTE NOCO|Wrong angle on connector wing on SCMTS|Damage |Damage during testing|SS - Controls -SCM Test Stand|Other mechanical components|Vendor related |Specification not followed
ZF|P6000090632|10/05/2013|priority 2 |Q3|Unknown|Unknown|Manifold block isnt marked  correct|NOTE NOPT ATCO NOCO|System drawings not checked by E&S|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|100068622|04/08/2014|priority 2 |Q3|Unknown|Unknown|Missing BOM & DWG for PN 100068622|NOCO ATCO NOTE|Product structure is missing BOM & DWG|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000125394|01/07/2015|priority 3 |Q3|Unknown|Unknown|Internal leakage too high from DCV's|NOTE NOCO ATCO NOPT|Too high leakage from DCV's|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZB|P6000029747|28/01/2014|priority 2 |Q1|Unknown|Unknown|Oljelekkasje på SCM #7 levert fra FMC|ATCO NOCO NOTE|Oil leakage from SCM in storaged|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000024191|08/04/2013|priority 1 |Q3|Unknown|Unknown|Não foi realizado o set out do PT|NOTE NOCO NOPT ATCO|PT não teve o set out realizado|Documentation |Procedure / Process Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|QA/QS/QI Related|Documentation error
ZF|P6000076121|12/08/2011|priority 2 |Q3|Unknown|Unknown|Found parts after flushing the module|NOTE NOPT ATCO NOCO|Contaminated m.block  chips found.|Machining Related |OBS-Burr/Chips|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZD|P6000028371|10/06/2008|priority 1 |Q2|SHELL|GOM|MPFM are not working properly on SEM B|NOTE ATCO NOPT NOCO|Error outside SCM  SW in test equipment|Test Related |OBS-Function|SS - Controls - Sensors|Flowmeter|Vendor related |Unknown
ZF|100054943|06/03/2008|priority 2 |Q3|WOODSIDE|Unknown|Replacement of DCV's|NOPT NOCO NOTE ATCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000107991|29/08/2014|priority 3 |Q3|Unknown|Unknown|No communication with gauge sim|NOCO ATCO NOTE NOPT|Operation mishap.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000039844|13/08/2009|priority 1 |Q3|SHELL|Unknown|Rust appeared at SCM top plate area|NOCO ATCO NOPT NOTE|Missing and wrong type Tectyl applyied|Coating/Plating |Coating defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|100035013|24/04/2009|priority 4 |Q1|SHELL|Unknown|GC#01 (ATS) SCM#13  Comm. failure during|NOCO NOTE NOPT ATCO|Card damaged and replaced|Damage |Wear & Tear|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Test |Damaged during testing
ZF|P7000016420|14/07/2010|priority 2 |Q3|Unknown|Unknown|Danos superficiais no revestimento|NOPT ATCO NOCO NOTE|Arranhões na peça|Coating/Plating |Coating defect|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Cause not found
ZF|P7000020444|17/05/2011|priority 1 |Q3|Unknown|Unknown|itens com revestimento diferente|NOPT NOTE NOCO ATCO|Revestimento|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Paintshop Related|Paint defect
ZF|P6000100953|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|TDV spurious reading|NOTE NOPT NOCO ATCO|TDV spurious reading|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P6000122626|04/05/2017|priority 2 |Q3|Unknown|Unknown|ZERO reading on DHI 2 on SEM B|ATCO NOCO NOTE|ZERO reading on DHI 2 on SEM B|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIIE|Electrical |Machine malfunction
ZF|P6000098616|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE ATCO NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000001621|25/02/2010|priority 1 |Q3|Unknown|Unknown|Defeito no anel roscado|NOCO NOPT ATCO NOTE|Por ca danificada|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Assy |Damaged during assembly
ZF|P6000068912|06/07/2011|priority 3 |Q3|Unknown|Unknown|SEM not mounted in correct position|ATCO NOCO NOTE NOPT|SEM not orientated acc to dwg|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|FMC Assy |Operator Error
ZF|100020278|20/07/2010|priority 1 |Q3|EXXONMOBIL|Unknown|Coupler replacement|NOPT ATCO NOTE NOCO|Coupler replacement|Test Related |OBS-Leakage (Fluid)|SS - Controls - Hydraulic Couplers|Hydraulic Coupler|Intercompany|FMC Kongsberg
ZE|P6000074156|28/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM) SEM Not able to communicate|NOCO NOTE ATCO NOPT|SEM Not able to communicate|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZB|P7000000897|23/11/2017|priority 3 |Q1|SHELL|Unknown|BC-10 - SCM SN 15 - CIT4 UVM|NOTI NOPR ATCO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000001621|17/05/2011|priority 1 |Q3|Unknown|Unknown|Fechamento da Outer  Can Hércules SN13|NOCO NOPT NOTE ATCO|decorrente do processo de reparo|Assembly Related |OBS-Interface issue|SS - Controls -Instrumentation|SCM Chemical Injection Valve|FMC Other causes/damage |Cause not found
ZF|100048038|09/09/2008|priority 1 |Q3|CHEVRON|WEST AFRICA|SCM incompatable|NOCO ATCO NOPT NOTE|SCM Pressure Readings Incompatable|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Equipment Malfunction
ZF|100020278|01/09/2009|priority 3 |Q3|EXXONMOBIL|Unknown|Megi Sea SCM 30 - status buffer values|ATCO NOTE NOPT NOCO|Procedure Needs to be updated|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Design Error
ZE|P6000107991|09/06/2017|priority 3 |Q3|Unknown|Unknown|F:IWCM backed out from funnel|NOTE ATCO NOCO|Root cause not identified|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Assembly |Other- Specify in comments
ZB|100067526|12/04/2016|priority 2 |Q1|Unknown|Unknown|Quality deviations OH 048 Gullfaks|ATCO NOCO NOTE NOPT|Customer Error/responsibility|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000039672|05/04/2016|priority 1 |Q3|Unknown|Unknown|Parafuso DCV Cisalhado no Manifold Block|NOPT NOCO ATCO NOTE|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Assy |Damaged during assembly
ZB|100035013|06/12/2013|priority 1 |Q1|Unknown|Unknown|Ormen Lange Claim SCM 21|NOTE ATCO NOCO|Seacon optical connector issue|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|P6000050867|28/10/2009|priority 3 |Q3|PETROBRAS|Unknown|Cascade DAS battery failure|ATCO NOCO NOTE NOPT|Cascade DAS battery failure|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Components|Vendor related |Equipment Malfunction
ZF|100050519|11/11/2013|priority 4 |Q3|Unknown|Unknown|SCM RELIEVING AT 5 PSI|NOCO ATCO NOTE|Huge amount of thread sealing glue|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZF|P6000063531|23/01/2014|priority 2 |Q3|Unknown|Unknown|SCM not mobilized acc. to FMC procedure|ATCO NOCO NOPT NOTE|No test equipment available|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missing Parts
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE NOCO ATCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|P6000080678|06/12/2016|priority 2 |Q1|Unknown|Unknown|Persephone SCM #5 Kulite PT failure.|NOPT ATCO NOCO NOTE|PT/TT failure|Electrical |Component Failure|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Assembly error
ZF|P6000093498|03/06/2015|priority 3 |Q3|Unknown|Unknown|SMU system error|NOTE NOCO ATCO NOPT|Follow-up in ZE QN 200416121|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Other causes/damage |Cause not found
ZF|P6000042969|01/10/2013|priority 3 |Q3|Unknown|Unknown|LP Return Flowmeter not working properly|ATCO NOPT NOTE NOCO|Flowmeter not counting minimum flow|Test Related |OBS-Missed Operation|SS - Controls -Instrumentation|SCM Flowmeter|Vendor related |Equipment Malfunction
ZE|P6000121268|20/10/2015|priority 3 |Q3|Unknown|Unknown|Leakage test outside criteria on FAT|NOTE ATCO NOCO NOPT|Not possible to detect leakage at suppli|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|QA/QS/QI Related|Operator error
ZB|3812476|14/07/2007|priority 4 |Q1|STATOIL|NORTH SEA|F&D Skid not match the base plate on SCM|NOCO NOTE NOPT ATCO|Correct skid not used|Assembly Related |OBS-Assembled Incorrectly|Customer Compliant|Noncompliance to Customer Requirement|FMC Other causes/damage |Planning error
ZF|P6000122574|19/08/2015|priority 3 |Q3|Unknown|Unknown|too long screw|NOPT ATCO NOCO NOTE|Part & BOM updated  ref ECN 6187549|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZE|P6000088751|21/12/2012|priority 2 |Q3|Unknown|Unknown|Update KS200e SW to 610.0|NOTE NOCO ATCO|To Update KS200e SW to 610.0|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P7000039672|22/05/2014|priority 3 |Q3|Unknown|Unknown|Gland does not fit on the Manifold Block|NOPT NOCO NOTE ATCO|1756 -UVDAL MASKINFABRIKK A/S|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Tooling
ZF|P7000024900|21/03/2012|priority 1 |Q3|Unknown|Unknown|Reverse flow of filter element|ATCO NOCO NOTE NOPT|arrived damaged|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000090632|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOPT NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000055605|13/11/2015|priority 3 |Q3|Unknown|Unknown|Unstable reading on PT 3|NOPT ATCO NOCO NOTE|Unstable PT  followed up in 200471731|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000068912|21/08/2012|priority 1 |Q3|Unknown|Unknown|SEM A  sensor fault|NOTE NOCO NOPT ATCO|Follow up QN 200308426|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|100035118|08/10/2013|priority 2 |Q3|Unknown|Unknown|broken bolt on EC8|NOTE ATCO NOCO|Reason for damage bolt not found|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Cause not found
ZE|P6000067527|28/06/2018|priority 3 |Q3|Unknown|Unknown|Rosneft Lan Do  SCM  communication error|ATCO OSNO|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|29/07/2015|priority 2 |Q3|Unknown|Unknown|falha comunicação mrms fora do criterio|NOPT NOTE ATCO NOCO|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|P6000068912|18/09/2013|priority 3 |Q3|Unknown|Unknown|Low voltage on SemB out 1|NOPT NOTE NOCO ATCO|Wiring issue  improp. wire fixing in ESS|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Improper handling
ZF|P6000104116|26/02/2015|priority 3 |Q3|Unknown|Unknown|DIU SN 28 failed under hyperbaric|NOPT NOTE NOCO|Failure in test equipment (jumper)|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100038200|09/02/2012|priority 3 |Q3|Unknown|Unknown|Anadarko SCM TST Procedure|NOTE NOCO ATCO|Anadarko SCM TST Procedure|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|P6000055213|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong type of screws used on valves|ATCO NOCO NOTE NOPT|Wrong type of screws used on valves|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000126219|06/02/2017|priority 3 |Q3|Unknown|Unknown|Water/oil contamination after hyperbaric|ATCO NOTE NOPT NOCO|Base plate not clean when assemble SCM|TEST |Leak|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Lack of Awareness
ZF|7104670|09/04/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOTE ATCO NOPT NOCO|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|100035013|15/11/2012|priority 2 |Q3|SHELL|Unknown|Damaged fiber penetrator Sem A|NOPT NOCO NOTE ATCO|Case follows in QN200335518|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|Vendor related |Clarification
ZF|P7000000229|26/04/2011|priority 1 |Q3|Unknown|Unknown|Top plate screws damaged .|NOPT NOCO ATCO NOTE|parafuso emperrado|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |Specification error
ZF|100015314|17/12/2014|priority 3 |Q3|Unknown|Unknown|HFT not linked to PN 100015314 in SAP.|NOCO NOTE ATCO|HFT not linked to P/N.|Documentation |Missing user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100038200|01/09/2010|priority 2 |Q3|"BHP BILLITON PETROLEUM AMERICAS| INHOUSTON STOCKING SCM MK II (15K)"|Unknown|HFT-0000021872 issues for GK_V SCM 63|NOPT NOCO NOTE ATCO|HFT-0000021872 issues for GK_V SCM 63|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|Unknown|Gluing of DHI212 board|ATCO NOCO NOTE|WD design improvement.|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000024191|12/09/2012|priority 1 |Q3|Unknown|Unknown|check danificada durante o teste|ATCO NOCO NOPT NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Other causes/damage |Damage from Wear and Tear
ZB|100052701|17/06/2010|priority 3 |Q1|STATOIL|NORTH SEA|Tyrihans Claim 015 MIV |ATCO NOTE NOCO|Unknown|FMC Other Defect |Functional|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Clarification
ZF|P7000024191|29/01/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #14 Can Bus & Serial Line|NOCO ATCO NOPT NOTE|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZE|P6000090632|30/04/2015|priority 2 |Q3|Unknown|Unknown|(SS)WOCM side B is faulty|NOPT NOCO ATCO NOTE|Unknown|Unknown|Unknown|SS - Controls - WOCS|Installation Workover Control System (IW|Variance|Capture Mistake
ZF|P6000029772|23/02/2009|priority 3 |Q3|Unknown|Unknown|No communicate with DWDM|NOTE NOPT ATCO NOCO|Most likely damaged contacts|Test Related |OBS-Function|SS - Controls - Electric Products|Electrical Components|FMC Test |Improper handling
ZF|P6000064911|06/06/2011|priority 3 |Q3|Unknown|Unknown|Wrong PN in bom|NOPT ATCO NOCO NOTE|Lack of inter-project communication|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|Non functioning PT|NOPT NOTE ATCO NOCO|Non functioning PT|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P7000039672|15/02/2017|priority 1 |Q3|Unknown|Unknown|SCM - Falha de comunicação DHI / DCVs|ATCO NOPT NOTE NOCO|||TEST |Function|Object Types to Eng Matl CLASS|scm_mkIIE|Intercompany|FMC Kongsberg
ZE|7104075|23/04/2014|priority 1 |Q3|Unknown|Unknown|Catastrophic FailureSCM Locking Mech-RED|NOCO NOPT NOTE ATCO|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|7104033|29/08/2013|priority 3 |Q3|Unknown|Unknown|W&T repair of sealing surfaces|ATCO NOTE NOCO NOPT|Unknown|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000104116|26/11/2014|priority 3 |Q3|Unknown|Unknown|Unit B side comunication failure|NOCO ATCO NOPT NOTE|Incorrect jumper in hyperbaric chamber|Damage |Damage during testing|SS - Controls - Electric Products|Electrical Components|FMC Test |Incorrect set up/testing
ZF|P6000110991|01/03/2017|priority 2 |Q3|Unknown|Unknown|Centrica Vale SCM fault dueto config DHI|ATCO NOCO NOPT NOTE|Procedure misinterpreted|Software |Program configuration|Object Types to Eng Matl CLASS|scm_mkIIE|FMC Engineering related |Procedure error
ZF|P7000016420|02/08/2011|priority 1 |Q3|Unknown|Unknown|Interior de Manifold Block com cavacos|NOPT NOTE ATCO NOCO|Bosch - manifold block c/ cavacos|Test Related |OBS-Cleanliness|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZE|100001156|23/02/2015|priority 2 |Q3|STATOIL|NORTH SEA|High Voltage applied to SCM|NOCO NOTE ATCO|Human error  no change of procedure|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000068902|17/04/2013|priority 2 |Q3|Unknown|Unknown|Smart ret. fitting missing o-ring|NOCO NOTE ATCO|O-ring not re-installed on smart return|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZF|P6000088614|10/08/2016|priority 3 |Q3|Unknown|Unknown|Top plate outside acceptance criteria|NOCO ATCO NOPT NOTE|Top plate outside accept criteria. DWG|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZF|P6000102554|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000043122|31/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Hydraulic filter fitted up side down|NOPT NOCO NOTE|Operator error  training is given|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000000229|30/10/2012|priority 1 |Q3|Unknown|Unknown|Teste Funcional - Frade #08|NOTE NOCO ATCO NOPT|MMR SCM|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Maintenance
ZF|P7000024900|27/08/2012|priority 1 |Q3|Unknown|Unknown|Nao conformidade Adapter Plate (LP)|NOPT NOTE ATCO NOCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P1000018406|30/01/2012|priority 3 |Q3|BP|Unknown|Weld Procedure not BP Approved|NOCO NOTE NOPT ATCO|Weld Procedure not BP Approved|Design |Procedure Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100052701|11/10/2012|priority 2 |Q3|STATOIL|NORTH SEA|Tyrihans 10 Pressure Test Leakage|NOTE NOPT NOCO ATCO|Leakage tests w/SCM procedure errors|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100036936|11/03/2005|priority 1 |Q3|Unknown|Unknown|To frequently  no response on SIO CARD|NOCO NOPT NOTE ATCO|HW/SW timing conflict at power-up|Assembly/Test Related |Do Not Use|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |DWG Error
ZB|100056918|11/07/2016|priority 3 |Q1|Unknown|Unknown|WEL Incorrect SCM installed|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Improper handling
ZF|P6000063531|09/11/2010|priority 2 |Q3|Unknown|Unknown|Error on folder on N:/ Server.|NOPT ATCO NOCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls -Computer system software|Network config|FMC Engineering related |Procedure error
ZF|P6000076121|08/09/2011|priority 3 |Q3|Unknown|Unknown|Bracket in outercan conflict|NOTE NOCO ATCO NOPT|Bracket conflict inside outercan|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZE|P6000088751|18/05/2018|priority 2 |Q3|Unknown|Unknown|Improvement for SN 300644919|NOPR OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZB|P6000105708|16/02/2016|priority 2 |Q1|Unknown|Unknown|Julia SRM #4 Defecte Bladder|NOTE ATCO NOCO|Contamination i bladder|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Assembly error
ZF|P6000102687|10/04/2014|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZD|7104075|23/07/2013|priority 3 |Q2|Unknown|Unknown|Face and Piston surface out of specs.|NOCO NOTE NOPT ATCO|EC seal surface finish out of tolerance|Machining Related |OBS-Surface Finish Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000103208|06/11/2013|priority 3 |Q3|Unknown|Unknown|Wrong position of SEM penetrator|ATCO NOTE NOCO NOPT|SEM rotated wrong during assembly|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100046387|21/04/2008|priority 3 |Q1|STATOIL|NORTH SEA|Guarantee claim 154 - Failure on jumper|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |Unknown|SS - Umbilical & Flowline - Well Jumper|Termination Head|FMC Engineering related |Engineering Error
ZF|100035118|10/02/2009|priority 3 |Q3|WOODSIDE|Unknown|Problems during DHI test|NOTE NOPT NOCO ATCO|No functional failure  only houskeeping|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Unknown
ZE|100064910|12/08/2015|priority 3 |Q3|Unknown|Unknown|Better design to get easy closing  SCM|ATCO NOTE NOCO|Proposals in MOM attached|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Obsolescence Issue:&|General
ZF|P6000068924|09/02/2016|priority 1 |Q3|Unknown|Unknown|Clov SRM # 16 Possible Optical p failure|ATCO NOTE NOPT NOCO|Leaking optical penetrator|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|P7000039672|17/02/2016|priority 1 |Q3|Unknown|Unknown|check valve abrindo fora do criterio|NOTE ATCO NOCO NOPT|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZF|P7000024900|30/09/2013|priority 1 |Q3|Unknown|Unknown|Variação na leitura do WLD|NOTE NOCO NOPT ATCO|||Assembly Related |OBS-Component Error|SS - Controls -SCM el/opt components|Other el/opt components|FMC Assy |Cause not found
ZE|P6000062990|09/03/2016|priority 3 |Q3|Unknown|Unknown|HFT Documentation Defects|NOTE ATCO NOCO NOPT|HFT Documentation  Defects|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000105542|14/12/2015|priority 3 |Q3|Unknown|Unknown|Unable to perform test according to HFT|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Missed Operation|SS - Controls -Instrumentation|Other SCM instruments|FMC Other causes/damage |Cause not found
ZF|100056176|09/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|B&B03 SCM not mobilized acc. to PSM|NOCO NOTE ATCO NOPT|Consession|Test Related |OBS-Test Omitted|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZF|P6000068902|07/03/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOPT NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000055605|19/02/2014|priority 3 |Q3|Unknown|Unknown|TOP PLATE|NOCO NOPT ATCO NOTE|Wrong angle on guide rail|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P6000068902|05/02/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOPT NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZD|P6000068912|30/07/2013|priority 2 |Q2|Unknown|Unknown|Missing Valve Cap P/N:100014108 from SCM|NOPT NOTE NOCO ATCO|Missing protection cap|Marking |No Marking|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|Intercompany|FMC Kongsberg
ZF|P7000000897|14/09/2011|priority 2 |Q3|Unknown|Unknown|Falhas no acabamento|NOPT NOTE NOCO ATCO|FMC BRASIL|Damage |Damage Due to Handling|SS - Compl. & W.Over - XT - General|Tree Assembly|FMC Assy |Damaged during assembly
ZF|P6000068912|04/05/2011|priority 3 |Q3|Unknown|Unknown|O rings for optical couplers missing|NOCO ATCO NOTE NOPT|Proj.mistake?O-rings not included in BOM|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|FMC Engineering related |Engineering Error
ZF|P7000039672|07/05/2014|priority 1 |Q3|Unknown|Unknown|Incorrect reading of pressure transducer|NOCO ATCO NOTE NOPT|2932 - Scan  Sense AS|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZD|100048038|07/10/2008|priority 1 |Q2|CHEVRON|WEST AFRICA|Agbami SCM #32 Damaged During Shipping|ATCO NOCO NOPT NOTE|Agbami SCM #32 Damaged During Shipping|Damage |Damage during transport|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage during transport
ZF|100015538|27/02/2013|priority 3 |Q3|Unknown|Unknown|Missing DBI on various PN|NOCO ATCO NOTE|Old parts not transferred to TCE.|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|100020278|22/04/2008|priority 2 |Q1|EXXONMOBIL|Unknown|PMV failed to operate via SCM|NOTE NOCO|PMV failed to operate via SCM|Test Related |OBS-Function|Subsea Control Module (SCM) Hydraulic|Hydraulic control valves|FMC Other causes/damage |Cause not found
ZE|P6000080678|11/12/2014|priority 3 |Q3|Unknown|Unknown|(CDM) SCM  Voltage issues|ATCO NOCO NOTE|Voltage issue|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|NOCO NOPT ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZD|P6000080678|10/12/2015|priority 4 |Q2|Unknown|Unknown|(CDM) SCM API Bucket Missing|NOPT NOTE NOCO ATCO|Missing component of SCM|Procurement |Incomplete Kit Of Parts|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Missing Parts
ZF|100037229|24/04/2009|priority 3 |Q3|Unknown|Unknown|Extra test FAT test section 7.4.9|NOCO NOPT NOTE|SCM tested without Gauge|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Unknown
ZF|P6000090632|20/04/2015|priority 2 |Q3|Unknown|Unknown|Silicone Leakage at bladder hose|NOTE NOCO ATCO|Silicone Leakage at bladder hose|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000039672|10/04/2014|priority 1 |Q3|Unknown|Unknown|ALLIGNMENT MARK OUT OF PLACE|NOPT ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT ATCO NOTE NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZB|100035119|25/09/2012|priority 2 |Q1|Unknown|Unknown|Warranty Claim SCM S/N 110|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000001843|07/03/2014|priority 1 |Q3|PETROBRAS|Unknown|MMR - TUM not communicating|NOCO NOTE ATCO|Overvoltage by incorrect set up|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other SEM (Non Standard)|FMC Test |Incorrect set up/testing
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|NOPT NOTE NOCO ATCO|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |QN Cancelled
ZF|7101401|23/06/2016|priority 3 |Q3|PETROBRAS|Unknown|MMR - Outer Can did not reach Vacuum|NOCO ATCO NOTE NOPT|SCM felt down on seabed|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Service Related:|Damaged during installation
ZF|P6000029747|18/11/2011|priority 3 |Q3|ENGIE|NORTH SEA|Repair SCM Internally detected failure|NOCO ATCO NOTE|PT fault|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000108025|05/02/2014|priority 3 |Q3|Unknown|Unknown|Too high leakage during leakagetest|ATCO NOTE NOCO NOPT|DCV leakage outside acceptance criteria|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000088604|18/03/2015|priority 2 |Q3|Unknown|Unknown|(CDM) check valves Leaking|NOPT NOTE ATCO NOCO|Check valves Leaking|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100035013|17/08/2010|priority 3 |Q3|SHELL|Unknown|Downloaded wrong SW to SCM|NOTE NOPT NOCO ATCO|Unknown|Assembly Related |OBS-Wrong Part Assembled|SS - Controls -Computer system software|Basis 200e SW|QA/QS/QI Related|Operator error
ZF|100056176|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOTE NOCO ATCO NOPT|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P7000039672|12/11/2014|priority 1 |Q3|Unknown|Unknown|Flowmeters sem leitura pela SEM A|ATCO NOCO NOTE NOPT|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Assy |Operator Error
ZF|P6000104115|08/08/2014|priority 3 |Q3|Unknown|Unknown|High current readings from PSDM.|NOCO ATCO NOTE|Extra grounding added  not as specified|Test Related |OBS-Function|SS - Controls -SCM el/opt components|Trafo Unit|FMC Engineering related |Engineering Error
ZF|P6000068924|16/11/2011|priority 1 |Q3|TOTAL|Unknown|Wrong use of miniseal|NOCO NOTE ATCO NOPT|Wiring list incorrect. followup200315427|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - Electric Products|Electrical Wire|FMC Engineering related |Engineering Error
ZF|100030542|21/08/2014|priority 3 |Q3|Unknown|Unknown|W&T - Corrosion on EC seal Surface|NOCO NOTE ATCO NOPT|Wear and tear.|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZB|7104670|22/07/2018|priority 2 |Q1|Unknown|Unknown|CIDV1 fault detected during SCM mob|NOTI NOPR OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000039672|29/02/2016|priority 1 |Q3|Unknown|Unknown|Term Shell Danificado - Conector ODI|NOCO ATCO NOPT NOTE|||Assembly Related |OBS-Physical Damage|SS - Controls -SCM el/opt components|El. Connector|Vendor related |Final Inspection Error
ZF|P6000069056|07/12/2011|priority 2 |Q3|STATOIL|NORTH SEA|SCM  earth fault in el. conn. EC1|ATCO NOPT NOTE NOCO|Ground wire too close to pin on board|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Assy |Damaged during assembly
ZF|100037966|04/04/2008|priority 2 |Q3|BP|Unknown|FPS NCR26 - Comnction Loss on SCM SEMA/B|ATCO NOCO NOTE NOPT|Still to be determined|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes |Do Not Use
ZF|P6000064909|08/08/2011|priority 2 |Q3|Unknown|Unknown|Wiring falure on COVHP|ATCO NOPT NOCO NOTE|Marking on soleonide A and B swithed|Marking |Marking content error|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Assy |Operator Error
ZF|100068622|01/12/2015|priority 2 |Q3|Unknown|Unknown|Multiphase Simulator testing InHouse/FAT|NOCO ATCO NOTE NOPT|Lack of functional CPI test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZE|P6000068924|07/01/2013|priority 3 |Q3|TOTAL|Unknown|Loose HCs in SRM manifold block.|NOPT NOTE ATCO NOCO|Couplers most likely not torqued|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|QA/QS/QI Related|Operator error
ZF|100048038|23/03/2018|priority 2 |Q3|Unknown|Unknown|SCM  Equipment structure in SAP missing.|OSTS NOPR|Parts not inculded in the eqp. structure|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIII|Documentation Requirement |Other- Specify in comments
ZF|100052701|05/10/2011|priority 2 |Q3|STATOIL|NORTH SEA|HP valves damaged do to high return pres|NOTE NOCO NOPT ATCO|Return hose blinded  SCMTS|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100016901|22/06/2010|priority 2 |Q3|Unknown|Unknown|Variance Form in SO book|ATCO NOPT NOTE NOCO|ACCEPTED|Documentation |Missing Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000039672|11/11/2013|priority 1 |Q3|Unknown|Unknown|FALTA DE MATERIAL DO CON. EL. DA O. CAN|NOPT ATCO NOTE NOCO|Teledyne Oil & Gas|FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |Cause not found
ZF|P6000073613|13/06/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|BPTH SKOFLO SCM SN #21 Wiring|NOPT ATCO NOTE NOCO|BPTH SKOFLO SCM SN #21 Wiring|Change/Deviation Request |Conversion approval|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Other external causes |Customer Error/responsibility
ZD|100050519|04/04/2013|priority 1 |Q2|Unknown|Unknown|Certs issue|NOCO ATCO NOTE|Unknown|Documentation |Missing Certificates / Records|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|Intercompany|FMC Kongsberg
ZD|P6000068902|26/03/2014|priority 2 |Q2|Unknown|Unknown|Wrong Tag marking|NOCO ATCO NOTE NOPT|Unknown|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage during transport
ZF|P6000079032|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|Insufficient wall thickness in m. block|NOPT NOTE NOCO ATCO|Ref. QN 200241870|Design |Drawing Error|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Engineering related |Engineering Error
ZF|100048038|14/01/2009|priority 3 |Q3|Unknown|Unknown|screw too large diameter for hole|NOTE NOCO ATCO NOPT|max at d1 is 8mm for M6 screw|Machining Related |OBS-Inside Diameter Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|100056443|08/03/2017|priority 3 |Q3|Unknown|Unknown|CR Unable to perform test accord to HFT|NOCO ATCO NOPT NOTE|Lack of test equipment|TEST |Missed Operation|SS - Controls -Instrumentation|Other SCM instruments|FMC Other causes/damage |Cause not found
ZF|7102969|25/09/2013|priority 3 |Q3|Unknown|Unknown|Incorrect coating application|ATCO NOTE NOCO|Unknown|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Paintshop Related|Paint defect
ZF|3805796|19/10/2010|priority 2 |Q3|CONOCOPHILLIPS|Unknown|Material not delivered to plant|NOPT ATCO NOCO NOTE|Taken into Aberdeen under wrong Project|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZB|100048038|27/02/2008|priority 1 |Q1|CHEVRON|WEST AFRICA|ICV3 PT sensor is reading erratic values|NOTE NOCO ATCO NOPT|ICV3 PT sensor is reading erratic values|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Pressure transducers|Vendor related |Equipment Malfunction
ZF|P6000104113|02/03/2015|priority 3 |Q3|Unknown|Unknown|Leak of hydraulic fluid from MCM|NOCO ATCO NOPT NOTE|PT not torqued correctly|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Test |Operator Error
ZF|P6000058949|10/06/2010|priority 2 |Q3|STATOIL|NORTH SEA|Missing information about looping.|ATCO NOCO NOTE NOPT|Incorrect flushing procedure|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|P6000108542|24/09/2014|priority 2 |Q3|Unknown|Unknown|SCM #2 fails on CIMV|ATCO NOTE NOCO|SCM #2 fails on CIMV|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Chemical Injection Valve|FMC Other causes/damage |Cause not found
ZE|P6000122626|07/02/2019|priority Unknown|Q3|Unknown|Unknown|SCM  Update to Agbami HFT 615 Procedure|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P7000000897|25/04/2014|priority 1 |Q3|Unknown|Unknown|Pre charge hose out of range|NOPT NOTE NOCO ATCO|Pre charge N² hose out of specification|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000144559|22/08/2017|priority 2 |Q3|Unknown|Unknown|Outer can drain port not correct.|NOCO ATCO NOTE|Drain ports are 10 CM to high.|Machining |Position Error|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000104116|08/05/2014|priority 2 |Q3|Unknown|Unknown|Unfunctional Configfile|ATCO NOTE NOPT NOCO|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|Unknown|Gluing of DHI212 board|ATCO NOTE NOCO|WD design improvement.|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000100953|11/12/2013|priority 4 |Q3|Unknown|Unknown|Too much leakage during leakage test FAT|NOTE NOPT NOCO|Fault finding in QN 200360907|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZE|P6000055605|30/08/2012|priority 3 |Q3|Unknown|Unknown|SEM B absolute pressure 1200 mBar|NOCO ATCO NOTE|Operator not trained correctly|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Lack of training
ZF|P7000008275|24/01/2012|priority 1 |Q3|Unknown|Unknown|Issue on PT 12 and PT 17.|ATCO NOPT NOCO NOTE|Tambau Project|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|Intercompany|FMC Kongsberg
ZF|P6000090632|06/07/2015|priority 2 |Q3|CHEVRON|Unknown|WOCMMMR Wheatstone PT Variance|NOTE NOCO ATCO|Followed up in QN 200451039|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100048038|14/10/2014|priority 3 |Q3|Unknown|Unknown|ESS is not fully performed|ATCO NOCO NOTE|FMC standard procedure used in testing|Test Related |OBS-Test Omitted|SS - Controls - Electronic Boards|Other SEM (Non Standard)|FMC Test |Operator Error
ZF|100050520|02/06/2014|priority 3 |Q3|Unknown|Unknown|Received SCM not according to THI|NOTE NOCO ATCO|Damage during shipping|FMC Other Defect |Physical|FKS Quality system issues|Noncompliance to Industrial Standard|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P7000020444|20/05/2011|priority 1 |Q3|Unknown|Unknown|furaçao desalinhada|NOTE NOPT ATCO NOCO|Bracket não monta|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|SEM Bracket|Vendor related |Specification not followed
ZE|P6000104116|19/01/2015|priority 3 |Q3|Unknown|Unknown|Unit B side comunication failure|ATCO NOCO NOTE|Insufficient check of test set up|Damage |Damage during testing|SS - Controls - Electric Products|Electrical Components|Causes for Improvement|Process/Procedure Ineffective
ZF|P6000103208|03/10/2013|priority 3 |Q3|Unknown|Unknown|Leakage between adapter and manifold b.|ATCO NOCO NOTE|Wrong torque used procedure not followed|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P7000020444|22/08/2012|priority 1 |Q3|Unknown|Unknown|Flowmeter não conforme|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOTE NOPT ATCO NOCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100020562|22/10/2009|priority 2 |Q3|Unknown|Unknown|BPTH ETU Text File Punchlist Items|NOCO NOPT NOTE ATCO|BPTH ETU Text File Punchlist Items|Design |Specification Error|SS - Controls - Test and Transportation|ETU / Smart Tool HW|FMC Other causes/damage |No Non-Compliance
ZB|7101463|27/08/2008|priority 1 |Q1|Unknown|Unknown|Latching Mechanism will not unlatch|NOCO NOTE NOPT|Unknown|Test Related |OBS-Function|WOCS Control Module (WOCM) Mech. w/MB|Locking mechanisms|Vendor related |Equipment Malfunction
ZF|P6000029772|06/04/2016|priority 2 |Q3|Unknown|Unknown|Clearence issue mounting fiber pen.|NOCO NOTE ATCO|Consequence of changin fiberpenetrator|Assembly Related |OBS-Interface issue|SS - Controls -SCM  SEM el/opt component|Optical Penetrator (Insert)|FMC Engineering related |Engineering Error
ZE|P7000039672|06/02/2018|priority 4 |Q3|Unknown|Unknown|RCA _ SCM colapsado durante teste Hiperb|OSTS NOPR|Unknown|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Outer Can|Assembly |Procedures not Followed
ZF|100037427|12/06/2013|priority 1 |Q3|Unknown|Unknown|DHI 113 functionality Rosa Capital Spare|NOTE ATCO NOCO|Old specification  No update action|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZE|P6000068912|22/11/2013|priority 2 |Q3|Unknown|Unknown|S/N 6 was sent to Dunfermline|NOCO NOTE ATCO|Damaged by faulty PT|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Material error
ZF|P7000016420|05/09/2011|priority 1 |Q3|Unknown|Unknown|Base Plate P55/10|NOTE NOPT ATCO NOCO|USILIDER - BASE PLATE|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
ZF|100052701|01/09/2009|priority 2 |Q3|STATOIL|NORTH SEA|MPFM uanble to connect with SEM A.|NOTE NOPT NOCO|Poor crimp on cableshoe|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|100015314|04/11/2008|priority 2 |Q1|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|Unknown|SCM Ruptured Bladder|NOCO NOPT ATCO NOTE|Storage conditions (temp fluctuation)|Design |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Specification error
ZF|P6000069820|06/01/2012|priority 2 |Q3|CONOCOPHILLIPS|Unknown|(SS) MRM Software Version update|NOPT ATCO NOCO NOTE|MRM Software Bug Fix|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000108025|16/01/2014|priority 3 |Q3|Unknown|Unknown|HP flowmeter not measuring correctly|ATCO NOCO NOTE NOPT|Unstable readings from HP flowmeter|Test Related |OBS-Component Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|100046112|02/05/2013|priority 1 |Q3|Unknown|Unknown|Lost communication from SEM A|NOCO NOTE ATCO NOPT|short in DHI-board shorted 24V supply|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|100048038|08/08/2008|priority 1 |Q3|CHEVRON|WEST AFRICA|Damaged plug from  EC12 Sensor Harness|NOCO NOTE ATCO NOPT|Unknown|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZF|P6000055605|08/04/2014|priority 3 |Q3|Unknown|Unknown|Wrong pressure on PT when operating CVHP|NOPT ATCO NOTE NOCO|Wiring error. dicovered in hyper.b.ZE QN|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000001621|04/11/2013|priority 1 |Q3|PETROBRAS|Unknown|MMR- CVLP 29 LEAKAGE|NOCO ATCO NOPT NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Damaged during testing
ZF|100055762|17/01/2013|priority 3 |Q3|Unknown|Unknown|Wetgas test not performed|ATCO NOPT NOTE NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000119039|21/01/2015|priority 3 |Q3|Unknown|Unknown|Vacuum rør for kort fra lager|ATCO NOTE NOCO|Vacuum pipes cut too short|Assembly Related |OBS-imension (tolerance)|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Machine Shop Personnel |Operator error
ZF|P6000121393|05/08/2015|priority 3 |Q3|Unknown|Unknown|Canbus 5 on SEM B fault on test|ATCO NOPT NOCO NOTE|NO SCM failure  => TS cabling issue|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100049000|06/06/2011|priority 3 |Q3|BP|GOM|Replace HC 10 and HC 22|NOCO ATCO NOTE NOPT|Replace HC10 & HC22|Damage |Damage during assembly|SS - Controls - Hydraulic Products|Coupler|FMC Assy |Damaged during assembly
ZE|P6000103208|19/06/2014|priority 4 |Q3|Unknown|Unknown|Faulty test cable used during SCM FAT|NOPT ATCO NOTE NOCO|Unknown|Unknown|Unknown|FKS Quality system issues|Measuring  Analysis & Improvement|Variance|Enhance Process
ZF|P7000039672|13/03/2014|priority 1 |Q3|Unknown|Unknown|Trafo sem marcação de alinhamento|ATCO NOPT NOTE NOCO|Unknown|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZF|P6000042968|08/01/2014|priority 2 |Q3|Unknown|Unknown|TIF board err after XT install incident|NOTE NOPT NOCO ATCO|Unknown|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZB|P6000104112|23/08/2017|priority 3 |Q1|Unknown|Unknown|Egina WC 0023 -SCM 21 Conn stuck.|NOPR NOTI OSTS|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|P6000039844|05/12/2013|priority 3 |Q3|Unknown|Unknown|Fault on config|NOCO NOTE ATCO NOPT|Unknown|Design |Specification Error|SS - Controls -Computer system software|SEM/TPU config|FMC Engineering related |Engineering Error
ZF|P7000039672|19/09/2017|priority 1 |Q3|Unknown|Unknown|SEM Bracket - Misaligned / Desalinhada|NOPT NOTE NOCO ATCO|Unknown|Assembly |Misalignment / Interface Error|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Assembly error
ZE|P7000039672|03/12/2013|priority 4 |Q3|Unknown|Unknown|Adapter Plate danificada durante desmont|NOTE NOCO ATCO|BOSCH REXROTH LTDA.||Assembly Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Capture Mistake
ZB|P6000068902|11/07/2014|priority 3 |Q1|Unknown|Unknown|Clov Claim 001 - PT on SCM 012|NOCO ATCO NOPT NOTE|PT failure|FMC Other Defect |Functional|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000147859|28/06/2018|priority 3 |Q3|Unknown|Unknown|DHI Issues during Victor Charlie Comms|ATCO NOTE NOPT NOCO|CPI - DHI Card faulty|TEST |Function|Object Types to Eng Matl CLASS|tree_assembly|Intercompany|FMC Kongsberg
ZF|7104033|17/02/2014|priority 4 |Q3|Unknown|Unknown|Misleading info. in test procedures SCM|NOCO ATCO NOTE|Test procedures improved for clarity|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P6000088751|04/11/2016|priority 3 |Q3|Unknown|Unknown|PT 58 failed|ATCO NOTE NOCO NOPT|PT followed up in ZE QN200519225|TEST |Component Error|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Equipment Malfunction
ZF|P7000008275|17/07/2012|priority 1 |Q3|Unknown|Unknown|Valores abaixo do critério de aceitação|NOCO NOPT NOTE ATCO|Simulador Apresentou avaria|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|3810872|19/01/2016|priority 3 |Q3|Unknown|Unknown|Offset on holes for lifting sling|NOPT ATCO NOCO NOTE|Production error when SCM were produced|Machining Related |OBS-Position Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Cause not found
ZE|100051991|26/04/2017|priority 3 |Q3|Unknown|Unknown|Vincent  SCM  Flushing not done|NOCO ATCO NOTE|SCM Flushing not done|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Test |Procedures not Followed
ZE|100020562|20/02/2009|priority 2 |Q3|BP|GOM|CAR1 Implement RCA Actions_1 RPT10033107|NOPT NOCO NOTE ATCO|Implement RCA RPT10033107 Recommendation|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Causes for Improvement|Documentation
ZF|P7000001843|08/04/2014|priority 2 |Q3|PETROBRAS|Unknown|MMR - SEMs A and B Communication Failure|ATCO NOTE NOCO|Unknown|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P7000039672|13/03/2014|priority 1 |Q3|Unknown|Unknown|Trafo sem marcação de alinhamento|NOTE NOPT ATCO NOCO|FMC KONGSBERG SUBSEA AS|Marking |No Marking|SS - Controls -SCM el/opt components|Trafo Unit|Intercompany|FMC Kongsberg
ZE|P6000068924|26/04/2015|priority 2 |Q3|Unknown|Unknown|Proced update SRM HFT - Luanda Workshop|NOTE NOCO|Update is followed up in QN 200439169|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|100037965|14/06/2017|priority 4 |Q3|Unknown|Unknown|CREATED IN ERROR|NOCO NOTE NOPT ATCO|Unknown|Change/Deviation Request |Part substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Planning error
ZF|P6000069056|06/11/2012|priority 2 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P7000016420|14/10/2011|priority 2 |Q3|Unknown|Unknown|SRT  P-55 SN09|NOPT ATCO NOTE NOCO|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Test |Incorrect set up/testing
ZE|P6000088604|07/10/2015|priority 4 |Q3|Unknown|Unknown|(CDM) Wheatstone  SCM  Pressure Fault|NOCO NOTE ATCO|Faulty gas accumulator fitting of SCM|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100046387|13/07/2009|priority 4 |Q1|STATOIL|NORTH SEA|No communication with N-1SEM A|NOTE NOCO ATCO|SCM needs to be upgraded|Test Related |OBS-Function|SS - Controls - Topside Products|Subsea Control Unit (SCU)|FMC Other causes/damage |No Non-Compliance
ZF|3812476|28/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|Identified defect rectifier bridge|NOTE NOCO ATCO NOPT|Used component with wrong rating|Damage |Damage during testing|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Wrong Part Delivered
ZF|100034440|26/02/2009|priority 3 |Q3|NYTT KONTROLLSYSTEM|Unknown|Loose EC connectors|NOPT ATCO NOTE NOCO|Accepted Per LLOG Representative|Assembly Related |OBS-Interface issue|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |No Non-Compliance
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|Dial caliper coupler measurements|ATCO NOCO NOPT NOTE|Dial caliper coupler measurements|Machining Related |OBS-Position Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000088626|12/04/2018|priority 1 |Q3|Unknown|Unknown|SCM Installation of SCM on SCMMB PMA WS2|NOTE ATCO NOCO|Dust prot. on SCCMB when SCM was mounted|TEST |Damaged During Testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000069056|18/08/2011|priority 2 |Q3|Unknown|Unknown|Dual PT feiler|NOCO NOTE NOPT|Operator forgot to connect wire 129|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000063531|01/02/2013|priority 2 |Q3|Unknown|Unknown|Mob incomplete - lack of test equipment|NOPT NOTE NOCO ATCO|SESI sold to 3rd party|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000121393|12/03/2015|priority 3 |Q3|Unknown|Unknown|o-rings on plug|NOPT NOCO ATCO NOTE|Improve storage control on o-ring|Machining Related |OBS-Miscellaneous|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
ZB|100035014|04/03/2010|priority 2 |Q1|STATOIL|Unknown|GC#34  Serious I/O-problems on TemplateA|NOCO ATCO NOTE|Unknown|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Other Eletronic Boards|Projects Related|Material error
ZE|P6000091085|11/08/2016|priority 3 |Q3|Unknown|Unknown|(N) - Child CAR -OWIRS- Deadman sequence|NOPT NOCO ATCO NOTE|Unknown|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Documentation
ZF|P6000080343|07/12/2012|priority 2 |Q3|TULLOW|Unknown|Lock mech screws broke during test|ATCO NOTE NOCO|Bolts missing in SCM locking mechanism.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|100020562|21/01/2010|priority 3 |Q3|BP|GOM|BPTH SCM 26 LP supply PT issues|NOCO NOPT ATCO NOTE|BPTH SCM 26 LP supply PT issues|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZF|P7000001843|02/08/2011|priority 1 |Q3|Unknown|Unknown|Flow meter retorno LP e retorno HP|NOCO NOPT ATCO NOTE|Flow technology|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|P6000068912|21/10/2013|priority 2 |Q3|Unknown|Unknown|loose screws on outercan|NOCO NOPT NOTE ATCO|Five un-torque screws found by QA|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100036936|26/11/2010|priority 4 |Q1|STATOIL|NORTH SEA|Error on PCIM-B|NOPT ATCO NOCO NOTE|Damage during testing on PCIM|FMC Other Defect |Functional|SS - Controls -SCM Test Stand|Electrical Jumper|FMC Test |Damaged during testing
ZF|P6000058949|29/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|ATCO NOTE NOCO NOPT|Engineering error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P6000076121|04/01/2012|priority 1 |Q3|LIU HUA 4-1|Unknown|(SS) Frequency and Software issue in SCM|NOTE ATCO NOPT NOCO|Frequency and Software issue in SCM|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZB|100049000|29/08/2008|priority 1 |Q1|BP|GOM|DHFC SCM 06 SEM A RAM Warning|ATCO NOTE NOPT NOCO|Defective RAM chip|Damage |Unknown|Subsea Control Module (SCM) Electrical|Processor PCBs|Vendor related |Material error
ZF|P7000001843|20/04/2011|priority 1 |Q3|Unknown|Unknown|revestimento|NOCO NOTE NOPT ATCO|Revestimento danificado|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Locking Mechanism|FMC Other causes/damage |Damage from Wear and Tear
ZB|P6000065528|03/03/2014|priority 2 |Q1|Unknown|Unknown|LT NCR 23: Gas Accumulator in WOCM|NOCO NOTE ATCO|Unknown|Assembly Related |OBS-imension (tolerance)|FKS Quality system issues|Engineering System|FMC Other causes/damage |No Non-Compliance
ZB|P6000065886|12/02/2013|priority 3 |Q1|Unknown|Unknown|Alve Claim 222 SCM failed SEM B|ATCO NOPT NOTE NOCO|Electronic card failure|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZE|100056443|06/04/2017|priority 2 |Q3|EDISON/EDF|NORTH SEA|SEM Uncontrolled DCV oper.(Ribbon cable)|OSTS NOPR|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown|Unknown
ZF|100036936|27/01/2014|priority 4 |Q3|Unknown|Unknown|Missing information in DWG for SCM|NOTE ATCO NOCO|Missing items for EC's in DWG|Marking |Marking Location Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Engineering related |DWG Error
ZF|7103233|21/10/2010|priority 2 |Q3|SUNCOR|Unknown|SCM returned to FMCK on MMT|NOTE NOPT NOCO ATCO|Goods Receiving Inspection error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZE|P6000074156|06/01/2012|priority 3 |Q3|Unknown|Unknown|new way to attach earthing rail|NOPT ATCO NOTE NOCO|New parts in project BOM.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P6000138867|24/10/2016|priority 4 |Q3|Unknown|Unknown|PT issue during hyperbaric|NOPT NOTE NOCO ATCO|PT issue during hyperbaric|TEST |Function|Object Types to Eng Matl CLASS|scm_mkIIE|Vendor related |Equipment Malfunction
ZF|P7000000897|08/08/2012|priority 2 |Q3|Unknown|Unknown|screw stuck in base plate.|ATCO NOCO NOTE NOPT|SCM MMR|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Baseplate|Other external causes |Customer Error/responsibility
ZF|100049392|04/03/2013|priority 2 |Q3|Unknown|Unknown|SCM not washed after retrieved (F&D09)|NOCO ATCO NOTE|SCM not washed after retrieved (F&D09)|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Goods Receiving Inspection error
ZF|P7000024191|04/01/2013|priority 1 |Q3|Unknown|Unknown|PT com resíduo metálico.|NOTE ATCO NOPT NOCO|2932 - SCAN SENSE AS - PO 47456833-8|Assembly Related |OBS-Interface issue|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Final Inspection Error
ZF|P6000064909|14/04/2013|priority 3 |Q3|Unknown|Unknown|SCM - Document Updates|ATCO NOCO NOTE|HFT procedure updated with referance.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100036232|25/01/2018|priority 2 |Q3|Unknown|Unknown|Incorrect purch of products and serices|NOTE ATCO NOCO|Traceability List - no ref. to  SEM615|Change/Deviation Request |Process substitution request|FKS Quality system issues|Product Realization|Documentation Requirement |Input requirements missing
ZF|P6000074156|14/01/2013|priority 3 |Q3|Unknown|Unknown|Chipping of coating on outercan.|ATCO NOTE NOCO|Chipping of coating on outercan.|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |No Non-Compliance
ZF|100017278|27/07/2009|priority 3 |Q3|Unknown|Unknown|Test problems|ATCO NOTE NOPT NOCO|No failure in marking|Marking |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZD|P6000088751|22/02/2013|priority 1 |Q2|Unknown|Unknown|(SS) WEL GWF SCM missing internal O-ring|NOTE ATCO NOCO|SCM missing internal O-ring|FMC Other Defect |Part Lost|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Missing Parts
ZF|P6000029772|17/10/2012|priority 3 |Q3|ENGIE|NORTH SEA|Stuck strainer for silicone compensator|ATCO NOPT NOTE NOCO|Marginal materials specified|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000102687|04/04/2014|priority 3 |Q3|Unknown|Unknown|Re assemble FO on ESRS with clips|NOCO NOTE NOPT ATCO|Design improved  ref ECN6158709|Design |Drawing Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Continuous Improvement
ZB|P1000004979|10/07/2009|priority 3 |Q1|BP|GOM|Coffee cups used as protection caps|NOCO ATCO NOTE|shipping procedures not followed.|FMC Other Defect |Physical|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Materials/Stores related |Improper Packaging & Storage
ZE|P6000074156|22/07/2013|priority 1 |Q3|Unknown|Unknown|SCM LP  & HP Overpressure S #401- ORANGE|NOCO ATCO NOTE NOPT|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZB|100064910|11/05/2016|priority 1 |Q1|Unknown|Unknown|Åsgard GC 179117 SCM electronic failure|NOCO NOTE ATCO NOPT|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZB|7104670|30/03/2010|priority 1 |Q1|STATOIL|NORTH SEA|Warranty claim 108 - SCM & FCM failure|ATCO NOPT NOTE NOCO|Removed cover on couplings prior to inst|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Operator error
ZF|P7000008275|23/11/2012|priority 1 |Q3|Unknown|Unknown|Fio do Conector Eletrico Danificado|NOPT NOCO ATCO NOTE|1021-Teledyne Oil & Gas - SN1009662-544|Assembly Related |OBS-Interface issue|SS - Controls - Electric Products|Electrical Connector|Vendor related |Final Inspection Error
ZF|P6000065886|01/11/2011|priority 3 |Q3|STATOIL|NORTH SEA|Transposition error on cable lables|ATCO NOCO NOTE NOPT|Wrong wiring of transformer|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Engineering related |Lack of Training
ZF|100049000|21/06/2011|priority 1 |Q3|BP|GOM|Investigate Coupler Rotation-BPAT SCM 29|NOPT NOTE ATCO NOCO|Investigate Coupler Rotation-BPAT SCM 29|Machining Related |OBS-False Cut|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Programmer Error
ZF|P6000105708|21/08/2014|priority 2 |Q3|EXXONMOBIL|GOM|SRMDT  Julia SN 05  Redesign/ Reconfig|NOCO NOTE NOPT ATCO|Insufficient silicone comp  ref. RCA|Design |Specification Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|100048038|26/05/2010|priority 3 |Q1|CHEVRON|Unknown|SCM 5 Compensator Bladder|ATCO NOCO NOTE|Eratic HPU pressure|Damage |Damage during testing|Control System Topside Hydraulic Eq.|Hydraulic Power Unit (HPU)|Vendor related |Equipment Malfunction
ZE|P6000031350|27/03/2014|priority 3 |Q3|Unknown|Unknown|Damaged wire|NOCO ATCO NOPT NOTE|Wires stretched  incorrect lifting opera|Assembly Related |OBS-Physical Damage|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P7000039672|14/03/2016|priority 1 |Q3|Unknown|Unknown|Oxidação nos Dogs|ATCO NOCO NOTE NOPT|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Locking Mechanism|Vendor related |Coating Defect
ZF|P6000093498|18/06/2015|priority Unknown|Q3|Unknown|Unknown|LLP WOCM Communication Failure|NOTE ATCO NOCO|SW issue  Followed up in QN200473687|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000088751|31/05/2016|priority 3 |Q3|Unknown|Unknown|Wiring Error.|ATCO NOCO NOTE NOPT|RCA to be performed in ZE QN 200501401|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000077638|12/12/2015|priority 1 |Q3|Unknown|Unknown|Unknown|NOTE NOCO ATCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|QA/QS/QI Related|Final Inspection error
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|Unknown|(SS)SCM - Product Improvement|ATCO NOTE NOCO NOPT|Unknown|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOPT NOTE NOCO ATCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P6000104111|09/03/2016|priority 3 |Q3|Unknown|Unknown|Another PN for test equipment to be used|NOCO NOTE ATCO|Another PN for test equipment to be used|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|100026328|12/09/2012|priority 1 |Q3|Unknown|Unknown|Avaria em leitura de PT's|ATCO NOCO NOPT NOTE|MMR SCM_ Manutenção corretiva|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Other Eletronic Boards|Other external causes |Customer Error/responsibility
ZF|P7000039672|16/01/2018|priority 3 |Q3|PETROBRAS|Unknown|MMR - Locking Mechanism Failure|ATCO NOCO NOPT NOTE|Technician did not follow procedure|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|SEM Bracket|Assembly |Procedures not Followed
ZF|P6000055605|22/08/2012|priority 3 |Q3|Unknown|Unknown|SEM B absolute pressure 1200 mBar|NOPT NOTE NOCO ATCO|SEM pressure not completely drained|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000113559|05/05/2014|priority 3 |Q3|Unknown|Unknown|ECs in top oriented 180degrees wrong|NOCO NOTE ATCO NOPT|Designer error  followup ZE200379221|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZD|P6000084242|08/02/2012|priority 1 |Q2|Unknown|Unknown|(SS)INCORRECT PARTNUMBER|NOCO ATCO NOTE NOPT|INCORRECT PARTNUMBER|FMC Other Defect |Physical|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Intercompany|FMC Kongsberg
ZF|P6000037215|26/11/2009|priority 3 |Q3|Unknown|Unknown|Gjøa manifolds|NOCO ATCO NOTE|Engineering failure.|Design |Drawing Error|SS - Controls - Electric Products|Transformer  Modules|FMC Engineering related |Specification error
ZF|100035013|17/08/2010|priority 3 |Q3|Unknown|Unknown|Fiber fault on D3 SEM A  Ormen Lange|NOTE NOCO|Fiber fault on D3 SEM A  Ormen Lange|Test Related |OBS-Component Error|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Other causes/damage |Cause not found
ZF|100037965|16/05/2014|priority 2 |Q3|Unknown|Unknown|Damage to SCM can and locking mechanism|ATCO NOTE NOCO|1000Nm may be too high to unlock the SCM|Damage |Wear & Tear|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000079984|16/12/2013|priority 3 |Q3|Unknown|Unknown|Assy/Exxon/SCM/Missing Alignment Pin|NOTE NOPT NOCO ATCO|Missing Alignment Pin|Assembly Related |OBS-Interface issue|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Missing Parts
ZF|P6000064909|07/06/2011|priority 3 |Q3|TOTAL|NORTH SEA|Wiring error and cut on hose from EC5|NOCO NOTE ATCO|Wires were switched. Human error.|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Test |Operator Error
ZF|P6000068924|11/04/2012|priority 3 |Q3|TOTAL|Unknown|Current reading in ST outside acc. crit.|ATCO NOCO NOTE NOPT|Reference current not same as measured|FMC Other Defect |Functional|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Engineering related |Procedure error
ZB|P6000101955|02/12/2016|priority 3 |Q1|Unknown|Unknown|SCM  SEM B failure|NOPT NOTE NOCO|See QN 200405310|Design |Procedure Error|Object Types to Eng Matl CLASS|scm_mkIII|FMC Engineering related |DBI error
ZB|P6000064909|21/06/2013|priority 1 |Q1|TOTAL|NORTH SEA|Laggan Claim 27 - SCM 05|ATCO NOTE NOCO|No fault found on SCM|FMC Other Defect |Functional|FKS Quality system issues|Product Realization|FMC Other causes/damage |Cause not found
ZF|P6000055605|28/02/2014|priority 3 |Q3|Unknown|Unknown|Leakage test failed|NOPT NOTE ATCO NOCO|Too high and unstable leakage from DCV|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|100020278|30/06/2014|priority 2 |Q3|Unknown|Unknown|ETU SW Configuration Error on SCM|NOCO NOTE NOPT ATCO|Due to no feedback/response from Houston|Design |Specification Error|SS - Controls -Computer system software|ETU SW|FMC Other causes/damage |QN Cancelled
ZF|100017278|05/04/2013|priority 2 |Q3|Unknown|Unknown|Nickel Coating of sealing area|ATCO NOTE NOCO|Damaged during maintenance|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Assy |Improper handling
ZD|7102969|08/12/2014|priority 3 |Q2|Unknown|Unknown|Outer can painted surfaces.|NOCO ATCO NOPT NOTE|Unknown|Coating/Plating |Incorrect Colour/Coating|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|P6000104111|18/08/2014|priority 4 |Q3|Unknown|Unknown|Update KS200e SW for Egina|NOTE ATCO NOCO|Com. functionality which was not cons.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000068912|07/06/2013|priority 3 |Q3|Unknown|Unknown|Loose bolts on outercan SCM.|ATCO NOTE NOCO|Operator distracted during an operation|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZB|100056261|28/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|SEM Common Alarm|NOTE NOCO ATCO|SEM Common Alarm|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|Other SCM Electrical|FMC Other causes/damage |Cause not found
ZF|P6000088751|09/01/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|100049000|23/06/2010|priority 2 |Q3|BP|GOM|Missing sign offs|NOCO NOTE ATCO NOPT|Missing signature.|Documentation |Incorrect Certificates / Records|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZF|P6000102687|14/03/2014|priority 3 |Q3|Unknown|Unknown|Fiber Penetrator broken|NOPT NOTE ATCO NOCO|Occasional opr failure|Damage |Damage during assembly|SS - Controls -SCM  SEM el/opt component|El/Opt Penetrator (Insert)|FMC Assy |Damaged during assembly
ZF|P6000105710|13/02/2014|priority 3 |Q3|Unknown|Unknown|Conector satt 180 grader feil|ATCO NOCO NOTE NOPT|Wrong position on EC (rotation)|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZF|P6000116166|08/03/2016|priority 3 |Q3|Unknown|Unknown|Too high internal leakage|NOTE NOPT ATCO NOCO|Leakage in CV - requesting CAR|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Engineering related |Engineering Error
ZF|P6000039844|07/10/2009|priority 3 |Q3|Unknown|Unknown|Gumusust SCM for marking inconsistencies|NOTE NOCO ATCO NOPT|Marking inconsistence on GA drawing|Design |Drawing Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |DWG Error
ZF|P7000039672|09/08/2013|priority 1 |Q3|Unknown|Unknown|Check Valve out of Acceptance Criteria|NOPT NOTE NOCO ATCO|1242 - HTS maskinteknikk as|Test Related |OBS-Component Error|SS - Controls -SCM  hyd/mech components|Check Valve|Vendor related |Equipment Malfunction
ZB|100048038|05/01/2010|priority 3 |Q1|CHEVRON|Unknown|Comm Board For Analog Input Burnt|NOTE NOCO ATCO|Comm Board For Analog Input Burnt|Test Related |OBS-Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Test |Damaged during testing
ZF|P7000000897|29/08/2012|priority 1 |Q3|Unknown|Unknown|Hyperbaric Test BC-10 SCM 29.|NOPT NOCO ATCO NOTE|QN aberta para registrar desvio de leitu|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000039672|09/06/2014|priority 1 |Q3|Unknown|Unknown|Missing screws in ODI Connector|NOTE ATCO NOCO NOPT|1021 - Teledyne Oil and Gas||FMC Other Defect |Part Lost|SS - Controls -SCM el/opt components|El. Connector|FMC Engineering related |Missing Parts
ZE|P6000105710|25/02/2014|priority 4 |Q3|Unknown|Unknown|Missing log files|NOTE ATCO NOCO|Workshop check list will be created|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Variance|Enhance Process
ZF|P6000069056|30/10/2017|priority 3 |Q3|Unknown|Unknown|Silicone leakage on EC7 - Concession Req|ATCO NOCO NOPT NOTE|Unknown. No visible damage.|Electrical |Other- Specify in comments|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZF|P7000039672|26/01/2015|priority Unknown|Q3|Unknown|Unknown|Incorrect reading of pressure transducer|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P6000074156|20/02/2012|priority 3 |Q3|SHELL|GOM|Blow out in hyperbaric 3  West Boreas|NOTE NOCO ATCO NOPT|Blow out in hyperbaric 3|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000098616|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE NOCO ATCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000058949|21/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|Wrong length on screws to the elcan.|NOPT NOCO NOTE ATCO|Incorrect screw lenght used in BOM|Design |DBI Error|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Engineering related |Engineering Error
ZF|100031223|04/02/2013|priority 3 |Q3|STATOIL|NORTH SEA|SCM  corrosion betw.can and connector|NOPT NOTE NOCO ATCO|Unknown|Damage |Damage from corrosion|SS - Controls -SCM  hyd/mech components|Outer Can|Projects Related|Material error
ZB|100020278|22/04/2008|priority 2 |Q1|Unknown|Unknown|Host SCSSV's failed to close ESD Level 2|NOCO NOTE|Unknown|Test Related |OBS-Function|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |Cause not found
ZB|100020562|20/08/2009|priority 3 |Q1|BP|GOM|Plug on LP Vent to Sea|NOTE NOCO ATCO|Plug on LP Vent to Sea|Assembly Related |OBS-Assembled Incorrectly|Subsea Control Module (SCM) Hydraulic|Other SCM Hydraulic|FMC Other causes/damage |No Non-Compliance
ZD|P6000079433|05/09/2013|priority 1 |Q2|Unknown|Unknown|Part/Cert Issue|NOCO ATCO NOTE|VL FINAL INSPECTION ERROR|VL CLARIFICATION REQUIRED|NVL HANDLING DAMAGE|NVL CAUSE NOT KNOWN|Damage |Damage Due to Handling|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000088614|19/09/2016|priority 3 |Q3|Unknown|Unknown|Water in silicone sample|NOCO ATCO NOTE NOPT|Leaking connection in hyperbaric tank|Damage |Damage during testing|Object Types to Eng Matl CLASS|scm_mkIII|FMC Test |Damaged during testing
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|NOPT NOCO NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZE|P6000080678|07/10/2014|priority 4 |Q3|Unknown|Unknown|(CDM) Xena - SCM Adapters not supplied|NOCO ATCO NOTE NOPT|Missing Adapters|Unknown|Unknown|SS - Controls -SCM  hyd/mech components|Other mechanical components|Causes for Improvement|Process/Procedure Not Being Followed
ZF|P7000024900|08/05/2012|priority 1 |Q3|SHELL|Unknown|Manifold Block Arranhado|ATCO NOTE NOCO NOPT|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Packaging/Handling
ZD|100055600|10/06/2008|priority 3 |Q2|TALOS|GOM|No DBI Available|NOCO NOTE NOPT ATCO|No DBI Available|Documentation |Missing Certificates / Records|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Specification not followed
ZF|P6000043714|04/05/2011|priority 2 |Q3|Unknown|Unknown|Noncomformance to HFT acceptance|ATCO NOTE NOCO NOPT|Nonconformance to HFT acceptance|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|Baseplate w. Penetrator (w/ or w/o PCON)|FMC Test |Incorrect set up/testing
ZF|P6000105542|15/10/2013|priority 3 |Q3|Unknown|Unknown|Low pressure in accumulator after FAT|NOCO NOPT NOTE ATCO|No gas leakage can be re-produced|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Accumulator|FMC Other causes/damage |Cause not found
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOTE ATCO NOCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000105710|13/02/2014|priority 3 |Q3|Unknown|Unknown|Connector satt 180 grader feil|NOCO ATCO NOTE NOPT|Wrong position on EC (rotation)|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Operator Error
ZE|P6000123495|01/10/2016|priority 4 |Q3|Unknown|Unknown|LP supply PT1A reading high - Kulite|ATCO NOTE NOCO|LP supply PT1A reading high - Kulite|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Component Malfunction
ZF|P7000016420|14/09/2011|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 07|ATCO NOCO NOPT NOTE|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - Test and Transportation|Other SCM Test & Transport equipment|FMC Test |Incorrect set up/testing
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 3 RCA Actions_2 from RPT10033107|NOCO ATCO NOTE|Wrong part number installed|Unknown|Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Causes for Improvement|Process/Procedure Not Being Followed
ZB|100035013|05/10/2015|priority 4 |Q1|Unknown|Unknown|Warranty Claim69-D3SCM#21 Malfunctioning|NOTE NOCO ATCO|D3 SCM#21 Malfunctioning fiber|FMC Other Defect |Functional|Customer Compliant|Noncompliance to Customer Requirement|Other external causes |Customer Error/responsibility
ZF|P7000016420|30/06/2011|priority 1 |Q3|Unknown|Unknown|Protection Ring não monta|NOCO ATCO NOPT NOTE|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Design Error
ZF|100048038|23/04/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|Wrong type of DHI 117 used in AGB S/N 32|NOCO NOTE NOPT|No failure  Misunderstanding|Assembly Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|FMC Other causes/damage |No Non-Compliance
ZB|100018082|22/11/2013|priority 1 |Q1|Unknown|Unknown|Warranty claim 246 - SCM on Mikkel B-3H|ATCO NOTE NOCO|Unknown|Assembly Related |OBS-imension (tolerance)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Material error
ZF|P6000083428|20/08/2013|priority 3 |Q3|Unknown|Unknown|PT 04 Over acceptance criteria|NOTE NOCO NOPT ATCO|PT 04 outside of the acceptance criteria|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|100037427|01/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|Error in FAT procedure and GA DWG|NOCO NOTE ATCO|DWG error|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZF|P7000039672|30/05/2014|priority 1 |Q3|Unknown|Unknown|Pt's Invertidos|NOCO NOTE ATCO NOPT|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM el/opt components|SCM Wiring|FMC Assy |Operator Error
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|Class 1 ECN 6083510|NOPT NOCO NOTE ATCO|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P7000039672|15/10/2015|priority 1 |Q3|Unknown|Unknown|Leitura incorreta do PT 22|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Other Eletronic Boards|Intercompany|FMC Kongsberg
ZF|P7000024900|01/11/2012|priority 1 |Q3|Unknown|Unknown|VAZAMENTO DE PRÉ-CARGA|NOCO NOPT ATCO NOTE|Unknown|Test Related |OBS-Leakage (gas)|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000067533|08/01/2013|priority 1 |Q3|Unknown|Unknown|SCM Modules stored outside with no PSM|ATCO NOCO NOTE|Improper storage|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P6000055213|06/08/2014|priority 3 |Q3|Unknown|Unknown|concession on SCM MK II  615  PROD/WIXT|NOTE ATCO NOCO NOPT|test equipment is unstable|FMC Other Defect |Functional|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Test |Incorrect set up/testing
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|CAR 4 RCA Actions_2 from RPT10033107|NOPT ATCO NOCO NOTE|Unknown|Unknown|Unknown|FKS Quality system issues|Product Realization|Causes for Improvement|Lack of Resources
ZF|P7000016420|05/10/2011|priority 1 |Q3|Unknown|Unknown|PT-61|NOTE NOCO ATCO NOPT|Kulite semiconductor|Test Related |OBS-Function|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZF|P7000001621|21/11/2011|priority 1 |Q3|Unknown|Unknown|CVLP #19 com grande vazamento|ATCO NOPT NOCO NOTE|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZE|P6000091085|11/08/2016|priority 3 |Q3|Unknown|Unknown|Child CAR - OWIRS - Deadman sequence|NOTE NOCO ATCO NOPT|Unknown|Unknown|Unknown|SS - Controls -Computer system software|Basis 200e SW|Causes for Improvement|Documentation
ZF|100001156|31/01/2014|priority 4 |Q3|STATOIL|NORTH SEA|Wrong Max Voltage in documentation.|NOCO ATCO NOTE|Wrong voltage on GA drawing|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000016420|09/11/2011|priority 3 |Q3|Unknown|Unknown|Exception code recieved when testing DHI|NOTE NOCO ATCO NOPT|Config file error|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Engineering related |Procedure error
ZB|100048038|14/12/2009|priority 3 |Q1|AGBAMI|Unknown|AGB20 32E1 SSGI cards 1 & 2 SEM A fault|NOCO NOTE ATCO|AGB20 32E1 SSGI cards 1 & 2 SEM A fault|Test Related |OBS-Function|Subsea Control Module (SCM) Electrical|DHI PCBs|FMC Test |Damaged during testing
ZF|P6000065886|14/09/2011|priority 3 |Q3|Unknown|Unknown|Revision change. Flowmeter adapter plate|NOCO NOPT ATCO NOTE|dwg updated see ECN 6102516|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZB|100017997|05/05/2010|priority 1 |Q1|BP|Unknown|BPTH IWOCS 4 excess fluid|NOPT ATCO NOTE NOCO|BPTH IWOCS 4 excess fluid|Test Related |OBS-Component Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000105542|10/12/2014|priority 2 |Q3|Unknown|Unknown|SCM manifold block failure - SN15|NOTE NOPT NOCO|Wrong welding pin defined for man. block|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Intercompany|FMC Dunfermline
ZF|P6000081371|17/08/2012|priority 3 |Q3|Unknown|Unknown|Outer Can coating error - run marks|NOCO ATCO NOTE|Coating on OC has marks from Hyperbaric|Coating/Plating |Coating defect|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Other causes/damage |Cause not found
ZF|P6000104116|27/04/2016|priority 3 |Q3|Unknown|Unknown|Child QN on DIU  (P6000104116)|NOTE NOCO ATCO|Unknown|Damage |Damage during assembly|SS - Controls -SCMMB|Other electric components|FMC Assy |Damaged during assembly
ZF|P7000016420|26/10/2011|priority 1 |Q3|Unknown|Unknown|Sem Bracket x Manifold Block|NOTE NOPT ATCO NOCO|Bosch - manifold block|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Specification not followed
ZF|7103382|25/02/2015|priority 3 |Q3|Unknown|Unknown|Incomplete BOM for PN 7103382|ATCO NOTE NOCO|Unknown|Obsolescence Issue:&|Not Available|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZE|P6000113559|15/05/2014|priority 3 |Q3|Unknown|Unknown|ECs in top oriented 180degrees wrong|NOTE NOCO ATCO|Wrong EC orientation on drawings.|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Projects Related|Documentation error
ZF|7101172|14/07/2011|priority 3 |Q3|STATOIL|NORTH SEA|Tronick coupler broken|NOTE NOPT NOCO ATCO|Wear and Tear|Damage |Wear & Tear|SS - Controls -SCM el/opt components|El. Connector|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000069056|12/10/2012|priority 1 |Q3|STATOIL|NORTH SEA|High pressure on return line|NOTE NOCO NOPT ATCO|RCA will be followed up in ZE 200288773|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000065886|22/10/2012|priority 2 |Q3|Unknown|Unknown|Testing not according to HFT procedure|NOPT ATCO NOCO NOTE|Testing not according to HFT procedure|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|P6000138873|19/11/2017|priority 2 |Q3|Unknown|Unknown|SCM - El.connenector clash.|NOTE NOCO ATCO|mounting base EC orinted 90 degrees wron|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|7101401|24/11/2014|priority 2 |Q3|PETROBRAS|Unknown|MMR - Outer Can Colapsed|NOTE NOCO NOPT ATCO|Unknown|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Outer Can|FMC Service Related:|Damaged during installation
ZF|P7000039672|27/05/2015|priority 1 |Q3|Unknown|Unknown|Danos em área de vedação  Manifold Block|NOCO NOTE ATCO NOPT|Unknown|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|FMC Other causes/damage |Cause not found
ZF|P7000039672|19/12/2016|priority 1 |Q3|Unknown|Unknown|PT com Mau funcionamento.|NOPT ATCO NOTE NOCO|Unknown|TEST |Function|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Operator Error
ZF|100056443|14/04/2010|priority 1 |Q3|STATOIL|NORTH SEA|SCM B Communication failure to WOCS.|ATCO NOCO NOPT NOTE|Ref ServiceNotification 300305855|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|QA/QS/QI Related|Final Inspection error
ZE|P6000088604|20/10/2015|priority 4 |Q3|Unknown|Unknown|(CDM) Accumulator Leakage CVX XT SCM #02|NOCO NOTE ATCO|Unknown|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZF|P6000063531|10/03/2015|priority 3 |Q3|Unknown|Unknown|Powered sem with too high voltage|ATCO NOCO NOTE NOPT|Wrong test procedure used|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|P7000024191|26/02/2013|priority 1 |Q3|Unknown|Unknown|Frequência da SEM B fora do especificado|NOCO ATCO NOPT NOTE|Unknown|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Engineering related |Continuous Improvement
ZF|7102643|30/10/2008|priority 3 |Q3|STATOIL|NORTH SEA|Scm not locked in skid.|ATCO NOCO NOTE NOPT|SCM not properly secured acc. tp procedu|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Test |Missed operation
ZF|P6000103208|25/10/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|ATCO NOTE NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZF|P6000065886|14/12/2010|priority 2 |Q3|ENI|NORTH SEA|Parts missing in BOM.|ATCO NOPT NOCO NOTE|Missing qty of parts BOM.|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DBI error
ZF|100049000|22/03/2011|priority 2 |Q3|BP|Unknown|Hydraulic Coupler/Port on SCM|NOTE NOPT ATCO NOCO|Hydraulic Coupler/Port on SCM|Raw Material |OBS-Defects in material|SS - Controls - Hydraulic Products|Coupler|FMC Other causes/damage |No Non-Compliance
ZD|100049000|20/09/2010|priority 3 |Q2|Unknown|Unknown|No DBI|NOCO ATCO NOTE NOPT|No DBI|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000000897|21/11/2011|priority 1 |Q3|Unknown|Unknown|check valves|NOPT NOCO ATCO NOTE|erro na execução do teste|Test Related |OBS-Function|SS - Controls -SCM  hyd/mech components|Check Valve|FMC Test |Operator Error
ZD|P6000122574|21/08/2018|priority 1 |Q2|Unknown|Unknown|FLM Kit not holding pressure|NOCO NOPT ATCO NOTE|Unknown|TEST |Leak|Object Types to Eng Matl CLASS|scm_mkIIE|Assembly |Trash / Burr / Contamination
ZF|P6000055605|24/01/2012|priority 4 |Q3|Unknown|Unknown|incorrect  values|NOCO NOTE ATCO|Incorrect Values|Design |Procedure Error|Common/Misc - General|Software|FMC Engineering related |ECN Change
ZF|P6000121268|12/01/2015|priority 1 |Q3|Unknown|Unknown|Range of Pressure Transmitter (PT)|NOTE NOCO NOPT ATCO|Range of Pressure Transmitter (PT)|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZB|100049000|07/04/2010|priority 2 |Q1|BP|GOM|DSCM16 Seized Locking Mechanism|NOTE NOPT ATCO NOCO|DSCM16 Seized Locking Mechanism|Damage |Wear & Tear|Subsea Control Module (SCM) Mech w/MB|Locking mechanisms|FMC Other causes/damage |Damage from Wear and Tear
ZF|P6000079984|20/08/2012|priority 3 |Q3|Unknown|Unknown|Canbus error|NOPT ATCO NOTE NOCO|Too high capacitance in ext.wiring|Test Related |OBS-Wrong Test Procedure Used|SS - Controls - Electric Products|Electrical Components|FMC Test |Incorrect set up/testing
ZF|140-141-004|28/10/2010|priority 1 |Q3|Unknown|Unknown|Conector de Base danificado|NOPT NOTE ATCO NOCO|Danos no Conector El. ODI 4pin|Damage |Damage during transport|SS - Controls -SCM el/opt components|El. Connector|FMC Materials/Stores related |Damaged During Transport
ZD|P6000100953|31/10/2013|priority 3 |Q2|Unknown|Unknown|crates damaged in trainsit|NOCO ATCO NOTE NOPT|crate damage during in transit|Damage |Damage during transport|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZE|P6000104115|02/09/2014|priority 4 |Q3|Unknown|Unknown|Water inside the SRM|NOCO NOTE ATCO|Assembly error|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Operator error
ZD|P6000090632|11/06/2015|priority Unknown|Q2|Unknown|Unknown|(SS) EDP WOCM no bootp call on PSDA Card|NOTE ATCO NOCO NOPT|Software related issue|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Second tier supplier issue
ZB|100051269|20/12/2017|priority 2 |Q1|Unknown|Unknown|No extra cost for witness 3rd part|NOPT ATCO NOTE NOCO|Contractual|Project|Project Requested Unfinished shipment|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Documentation Requirement |Other- Specify in comments
ZF|P6000042970|24/09/2009|priority 2 |Q3|TOTAL|WEST AFRICA|Error in ESS config file|NOTE NOCO NOPT ATCO|Unknown|Design |Unknown|SS - Controls - Topside Products|N/A SW|FMC Engineering related |Unknown
ZF|P6000055605|13/11/2014|priority 3 |Q3|Unknown|Unknown|Lost communication after switching|ATCO NOPT NOTE NOCO|Procedure failure  OMM60059036|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P7000024191|14/03/2013|priority 1 |Q3|Unknown|Unknown|Man. Global #19 Can Bus & Serial Line|ATCO NOPT NOTE NOCO|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100020278|14/07/2011|priority 3 |Q3|Unknown|Unknown|HFT-0000020573 needs to be updated|NOCO ATCO NOPT NOTE|Software update|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZD|P6000145982|26/06/2018|priority 1 |Q2|Unknown|Unknown|Damage issue|NOTE ATCO NOCO|VL DAMAGED DURING TRANSPORT|Damage |Damage during transport|Object Types to Eng Matl CLASS|scm_mkIIE|Coating |Damage
ZF|P7000039672|26/06/2014|priority 1 |Q3|Unknown|Unknown|protection ring ovalizada|NOPT NOTE NOCO ATCO|Unknown|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Other mechanical components|FMC Other causes/damage |Cause not found
ZF|P6000073687|13/06/2012|priority 3 |Q3|FRADE B.V.FRADE PH II|Unknown|HC2 and HC6 coupler damaged|NOCO NOPT ATCO NOTE|Damaged female couplers due to SCM TS|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Assy |Damaged during assembly
ZF|P6000121393|04/06/2015|priority 4 |Q3|Unknown|Unknown|Holstein 1 SCM Dekit|NOTE NOCO ATCO|250J40 Missed RIT of SCM|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZB|P6000101955|22/12/2015|priority 2 |Q1|Unknown|Unknown|Tyrihans SCM 05 Warranty 173957|NOTE NOCO ATCO|Unknown|FMC Other Defect |Functional|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Other causes/damage |Cause not found
ZF|P7000016420|17/01/2012|priority 1 |Q3|Unknown|Unknown|SRT SCM P-55 SN 13|NOPT ATCO NOCO NOTE|lab test box com fio solto|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P6000055198|05/03/2013|priority 2 |Q3|Unknown|Unknown|White layer on outercan|NOTE NOCO ATCO NOPT|White layer on outercan.|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Coating Defect
ZF|P6000104116|28/10/2014|priority 3 |Q3|Unknown|Unknown|O-ring surface too rough|NOCO NOTE NOPT ATCO|Sealing surface sandblasted follow-up QN|Machining Related |OBS-Surface Finish Error|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P7000024191|03/10/2012|priority 1 |Q3|Unknown|Unknown|SRT Global 10 can bus and Serial Line S2|ATCO NOPT NOTE NOCO|Lab test box with problem.|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|P7000016420|28/04/2012|priority 1 |Q3|Unknown|Unknown|Furo da Base Plate não conforme|NOPT NOTE NOCO ATCO|Revestimento na rosca|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|Vendor related |Specification not followed
ZF|P6000064911|03/10/2018|priority 2 |Q3|Unknown|Unknown|Cust. Dev. - Issues with SRM 4|ATCO NOCO NOPT NOTE|Unknown|Change/Deviation Request |Process substitution request|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Planning error
ZB|100020278|18/11/2009|priority 2 |Q1|EXXONMOBIL|Unknown|Comm's fault w/SCM 16|NOTE ATCO NOCO|Comm's fault w/SCM 16|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZF|P6000105542|26/02/2015|priority 2 |Q3|STATOIL|NORTH SEA|Hydraulic fluid in silicone oil sample|NOPT NOCO NOTE ATCO|Flatness on man. block not acc. to spec|Welding related |Miscellaneous|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P6000123495|29/09/2016|priority 1 |Q3|Unknown|Unknown|LP supply PT1A reading high - Kulite|NOCO ATCO NOTE|Follow up in ZE QN:200513101|TEST |Component Error|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Component Malfunction
ZF|P6000093498|16/06/2014|priority 1 |Q3|Unknown|Unknown|Communication problem on HS CAN BUS|NOTE NOCO ATCO NOPT|Internal HS Can-bus was not terminated|Test Related |OBS-Function|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Engineering Error
ZF|P7000039672|24/10/2014|priority 1 |Q3|Unknown|Unknown|ECN 7058839 - P7000017839|ATCO NOPT NOTE NOCO|ECN 7058839 - P7000017839|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100049000|10/06/2011|priority 3 |Q3|BP|GOM|Coupler verification for free rotation|NOPT NOTE NOCO ATCO|Coupler verification for free rotation|Assembly Related |OBS-Interface issue|SS - Controls - Hydraulic Products|Coupler|FMC Other causes/damage |No Non-Compliance
ZF|P6000042968|22/03/2010|priority 1 |Q3|TOTAL|WEST AFRICA|SCM software failure|NOPT NOTE ATCO NOCO|Downloaded software was not correct|Documentation |Procedure / Process Error|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Damaged during testing
ZF|P6000125392|24/11/2016|priority 3 |Q3|Unknown|Unknown|El can not according to specification|NOTE ATCO NOPT NOCO|Surface threatment not acc. to DBI.|Machining |Surface Finish Error|SS - Controls -SCM  hyd/mech components|SEM Can|Vendor related |Specification not followed
ZF|100035013|01/11/2012|priority 1 |Q3|Unknown|Unknown|Screws not torqued according to spec.|ATCO NOCO NOTE|Unknown|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Operator Error
ZF|100033987|09/04/2017|priority 3 |Q3|Unknown|Unknown|CR: CIDV not to be overhauled acc. to PO|NOCO NOPT ATCO NOTE|CIDV not to be overhauled.|Damage |Wear & Tear|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Test |Wear and Tear
ZE|P6000080343|03/04/2013|priority 3 |Q3|Unknown|Unknown|Investigation of metal found in flowmete|NOTE NOCO ATCO|Cause for metal chip not found.|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Manufacturing Engineering|ME programming
ZF|100058509|31/05/2010|priority 1 |Q3|Unknown|Unknown|LLOG GC448 fast scan issue|NOCO NOPT NOTE ATCO|Unknown|Design |Specification Error|SS - Controls - Topside Products|N/A SW|FMC Engineering related |Specification error
ZF|P6000129784|06/04/2017|priority 1 |Q3|LLOG|Unknown|High voltage on ethernet lines|NOCO NOPT NOTE ATCO|Applied 540VAC to ethernet wires|TEST |Damaged During Testing|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|FMC Test |Incorrect set up/testing
ZF|P6000065886|27/12/2010|priority 2 |Q3|ENI|NORTH SEA|CPU600 improving startup on long umbilic|NOCO NOTE ATCO|Recommended Improvement (QN200189637)|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Continuous Improvement
ZF|P6000090632|19/06/2013|priority 2 |Q3|Unknown|Unknown|Limited to 12 can nodes on PSD|NOTE NOPT NOCO ATCO|Limitation in Firmware on TRITON module|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZB|7102643|28/07/2012|priority 3 |Q1|Unknown|Unknown|Avbrutt SCM ops. etter feil anbefal. FMC|ATCO NOCO NOTE|Wrong info. from onshore support|FMC Other Defect |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000058949|03/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|Unstable DHI 119 on SEM A|NOPT ATCO NOCO NOTE|Wrong ID on DHI sensor-sim in use|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Clarification
ZF|P6000042308|01/12/2009|priority 3 |Q3|TULLOW|WEST AFRICA|Return system pressurized to 345 bar|NOTE ATCO NOPT NOCO|Manual Isolation valve on ATS was Closed|Test Related |Unknown|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Test |Operator Error
ZF|P7000008275|23/06/2014|priority 1 |Q3|PETROBRAS|Unknown|MMR - HW Leakage through Strainer|NOCO ATCO NOTE|Unknown|Damage |Damage during testing|SS - Controls -SCM  hyd/mech components|Compensator|FMC Test |Operator Error
ZD|P6000057855|17/02/2010|priority 3 |Q2|Unknown|Unknown|Communication failure SEM|ATCO NOPT NOCO NOTE|improper anchorage of intrconnect wires|Test Related |OBS-Function|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Engineering related |Continuous Improvement
ZF|P7000039672|18/06/2014|priority 1 |Q3|Unknown|Unknown|PT-13 com leitura incorreta|NOCO NOPT NOTE ATCO|SCAN-SENSE AS|Test Related |OBS-Component Error|SS - Controls -Instrumentation|SCM Pressure Transmitter|Vendor related |Equipment Malfunction
ZE|P6000105708|20/08/2014|priority 3 |Q3|Unknown|Unknown|RECALL ( Warranty) SRM's|ATCO NOCO NOPT NOTE|RECALL (WARRANTY ) SRM'S|Unknown|Unknown|SS - Controls - Topside Products|Topside Electronic Module (TEM)|Intercompany|FMC Kongsberg
ZF|P7000024900|19/09/2013|priority 1 |Q3|Unknown|Unknown|Strainer cisalhado|ATCO NOPT NOCO NOTE|2241 - RUSH MASKINERINGSENTER A/S|Assembly Related |OBS-Physical Damage|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Material error
ZB|100001156|21/07/2012|priority 3 |Q1|Unknown|Unknown|Leak in SCM|NOPT NOTE ATCO NOCO|Damage from Wear and Tear|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Damage from Wear and Tear
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|ATCO NOCO NOPT NOTE|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000098616|23/04/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOTE ATCO NOCO|No SCM failure detected in extend. test|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |No Non-Compliance
ZB|P6000043122|08/09/2010|priority 2 |Q1|TOTAL|Unknown|Coating is damaged|NOPT NOTE NOCO ATCO|Coating damaged|Coating/Plating |Painting Defect|SS - Controls -SCM el/opt components|El. Connector|FMC Test |Damaged during testing
ZB|100033987|24/01/2008|priority 1 |Q1|STATOIL|NORTH SEA|WARRANTY CLAIM 156 SEM RAM failure|NOCO NOPT NOTE ATCO|FMC guarantee acceptance|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Engineering related |Engineering Error
ZF|100037427|03/06/2013|priority 2 |Q3|Unknown|Unknown|wiring stressed during outercan assembly|NOPT NOTE NOCO ATCO|Damaged wire due accidental opr. errror|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Damaged during assembly
ZD|P6000042308|16/06/2016|priority 3 |Q2|Unknown|Unknown|Not coated per drawing specifications|NOPT ATCO NOCO NOTE|Not coated per drawing specifications|Coating/Plating |Painting Defect|SS - Controls -SCM  hyd/mech components|Outer Can|Vendor related |Specification not followed
ZF|100059660|14/02/2014|priority 2 |Q3|Unknown|Unknown|SCM not mobilized acc. to FMC procedure|NOTE ATCO NOCO NOPT|Re-evaluation of SOW due to need date|Test Related |OBS-Test Omitted|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P7000000897|13/10/2010|priority 1 |Q3|Unknown|Unknown|Flushing do compensador|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Cleanliness|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000079984|22/06/2012|priority 3 |Q3|EXXONMOBIL|NORTH ATLANTIC|marks on basplate mounted ECs|NOCO NOPT ATCO NOTE|Damaged due to incorrect EC pos on SCMTS|Damage |Damage during testing|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P7000024191|10/12/2012|priority 1 |Q3|Unknown|Unknown|Base plate danificada|NOCO ATCO NOPT NOTE|Sem evidência da causa|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Cause not found
ZF|P6000079433|12/07/2018|priority 3 |Q3|Unknown|Unknown|Missing CPI DHI simulator|NOCO NOPT NOTE ATCO|CPI test equipment missing|TEST |Missed Operation|Object Types to Eng Matl CLASS|scm_mkIIE|Test |Other- Specify in comments
ZF|100017278|18/03/2013|priority 3 |Q3|Unknown|Unknown|Testing not according to customer PO|NOTE NOPT ATCO NOCO|Lack of test equipment|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Tooling
ZF|100056443|11/01/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|Communication problems|NOPT NOTE NOCO ATCO|No failure in SCM  see attachment|Test Related |OBS-Function|SS - Controls - SS Control Module (SCM)|Subsea Control Module Mounting Base (SCM|FMC Other causes/damage |QN Cancelled
ZF|P6000068924|12/06/2012|priority 2 |Q3|TOTAL|Unknown|Loose HC`s in baseplate.|ATCO NOTE NOCO NOPT|RCA to be followed up in ZE 200296914.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|100056261|14/08/2009|priority 2 |Q3|Unknown|Unknown|Damaged Supply Flowmeter O-ring|ATCO NOPT NOTE NOCO|Damaged Supply Flowmeter O-ring|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |Unknown
ZE|P6000104116|15/10/2014|priority 3 |Q3|Unknown|Unknown|Damaged sealing surface|NOCO ATCO NOPT NOTE|No routines for cleaning clamping|Machining Related |OBS-Surface Finish Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Process/Procedure Ineffective
ZF|P7000000229|27/11/2012|priority 2 |Q3|Unknown|Unknown|Teste Funcional SCM Frade #09|NOTE NOCO NOPT ATCO|MMR SCM|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Vendor related |Maintenance
ZB|100051269|09/01/2017|priority 2 |Q1|Unknown|Unknown|Communication failure between SCM og ALD|ATCO NOTE NOCO NOPT|Statoil didnt wish t cont troubleshootin|Electrical |Functional|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|SCM outercan drawing error|NOTE ATCO NOCO NOPT|DWG error|Design |Drawing Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |DWG Error
ZE|100035118|07/06/2012|priority 2 |Q3|Unknown|Unknown|(SS)WEL Enfield SCM|ATCO NOTE NOCO|Torqued was too tight|Unknown|Unknown|SS - Controls - Hydraulic Products|Other Hydraulic Products|QA/QS/QI Related|Final Inspection error
ZF|100020562|24/09/2014|priority 3 |Q3|Unknown|Unknown|High LP DCV Leakage Rate|NOPT ATCO NOTE NOCO|Unknown|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Other external causes |Customer Error/responsibility
ZF|P7000039672|03/03/2017|priority 1 |Q3|Unknown|Unknown|ECN 6209019  PN P6000075566|ATCO DLFL NOCO|Error-documentation|Design |DBI Error|Object Types to Eng Matl CLASS|funnel_fabrication|FMC Other causes/damage |QN Cancelled
ZF|P6000063531|06/11/2014|priority 3 |Q3|STATOIL|NORTH SEA|Vigdis VEPIII rebuild Leakage|NOPT ATCO NOCO NOTE|DCV failed leakage test after overhaul|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Control Valve|Vendor related |Equipment Malfunction
ZF|7104670|22/10/2014|priority 3 |Q3|Unknown|Unknown|FSM Test in FAT not performed|NOCO ATCO NOPT NOTE|CPI test equipment not available|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Missed operation
ZB|100049000|28/04/2010|priority 3 |Q1|BP|GOM|DC121A DSCM 02 DH Gauges Readings Freeze|ATCO NOTE NOCO|Gauges Readings Freeze|Raw Material |OBS-Defects in material|Subsea Control Module (SCM) Electrical|DHI PCBs|FMC Other causes/damage |Damage from Wear and Tear
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOTE ATCO NOCO NOPT|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZB|100056443|13/05/2013|priority 3 |Q1|Unknown|Unknown|DT Communication problems with SCM/EHXT|NOPT NOTE ATCO NOCO|Time consuming operation.|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Other external causes |Customer Error/responsibility
ZF|P6000123495|07/10/2015|priority 3 |Q3|Unknown|Unknown|Problem with microcontroler 4 on SEM B|NOTE NOPT ATCO NOCO|Board to be investigated in new ZE QN|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Engineering related |Engineering Error
ZE|P6000104116|02/06/2014|priority 4 |Q3|Unknown|Unknown|Add guide pins to ensure correct assembl|NOPT NOCO ATCO NOTE|Continously improvement|Unknown|Unknown|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Causes for Improvement|Documentation
ZF|P7000001843|25/04/2014|priority 3 |Q3|PETROBRAS|Unknown|MMR - Problems with APSD2 card - Mex.#11|ATCO NOCO NOTE NOPT|Unknown|Damage |Damage during testing|SS - Controls - Electronic Boards|Other Eletronic Boards|FMC Test |Damaged during testing
ZF|P6000031350|03/12/2008|priority 1 |Q3|STATOIL|NORTH SEA|Wrong- hex-head instead of cap-screw|NOTE NOPT ATCO NOCO|No error - screw change with ECN 6044068|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZF|P6000103208|09/10/2013|priority 3 |Q3|Unknown|Unknown|Lost communicaton for a while in Burn in|NOCO NOTE|External Cause  no SCM failure|FMC Other Defect |Functional|SS - Controls - Electronic Boards|Main boards  CPU & I/O|FMC Other causes/damage |No Non-Compliance
ZF|P7000016420|27/09/2011|priority 1 |Q3|Unknown|Unknown|Parafusos sem lote marcado|NOCO ATCO NOTE NOPT|Parafusos sem lote marcado|Assembly Related |OBS-Assembly Not Serialized|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|QA/QS/QI Related|Documentation error
ZF|P6000132097|27/09/2018|priority 2 |Q3|Unknown|Unknown|Defect found in shipping inspection|NOPT ATCO NOTE NOCO|Unknown|Marking |Marking content error|Object Types to Eng Matl CLASS|scm_mkIII|FMC Other causes/damage |Cause not found
ZB|100017997|01/03/2010|priority 2 |Q1|BP|GOM|Roughness out of tol. on EC int. seal|NOTE NOPT ATCO NOCO|Roughness out of tol. on EC int. seal|Raw Material |OBS-Hardness out of tolerance|WOCS Control Module (WOCM) Mech. w/MB|Outer can|FMC Other causes/damage |Damage from Wear and Tear
ZE|P7000039672|17/02/2017|priority 4 |Q3|Unknown|Unknown|Outer can coating damage|NOPT ATCO NOCO NOTE|Poor surface preparation for coating|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Coating |Incorrect surface preparation
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO NOTE ATCO NOPT|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000126219|29/09/2017|priority 2 |Q3|Unknown|Unknown|Missing test of new PT found during FI|NOTE NOCO ATCO NOPT|misunderstanding between two technicians|TEST |Function|SS - Controls -SCM  hyd/mech components|Other hydraulic components|FMC Fabrication Shop Personnel |Operator error
ZF|100056443|28/09/2010|priority 3 |Q3|Unknown|Unknown|Documentation error VEGA|NOCO ATCO NOTE|Correction of old procedures|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000073613|28/06/2013|priority 3 |Q3|Unknown|Unknown|Spare 4-20mA sensors not in wiring list|ATCO NOTE NOPT NOCO|Wiring list was not updated|Assembly Related |OBS-Assembled Incorrectly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Specification error
ZB|P6000029747|10/09/2012|priority 2 |Q1|Unknown|Unknown|Gjøa Claim 057 SCM 015|NOTI ATCO NOPR|SEM failure - out of warranty|FMC Other Defect |Functional|SS - Controls -SCM  SEM el/opt component|Other SCM SEM el/opt components|Other external causes |Customer Error/responsibility
ZF|P7000024900|24/10/2014|priority 1 |Q3|Unknown|Unknown|LEITURA INCORRETA DHI113|NOPT NOCO ATCO NOTE|Unknown|Test Related |OBS-Component Error|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Intercompany|FMC Kongsberg
ZF|P6000079984|03/07/2012|priority 3 |Q3|Unknown|Unknown|Marks on baseplate mounted ECs|NOCO NOTE ATCO NOPT|Wrong angle on connector wing on SCMTS|Damage |Damage during testing|SS - Controls -SCM Test Stand|Other mechanical components|FMC Test |Damaged during testing
ZF|P7000001621|26/05/2010|priority 1 |Q3|Unknown|Unknown|Inspeção de Recebimento|NOPT NOTE ATCO NOCO|DEsmontagem sem RIRC|Documentation |Incorrect user documentation (customer)|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Lack of Training
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|Replacement of DCV's|NOPT NOTE ATCO NOCO|DCV/COV with Cobalt pilot ball|Raw Material |OBS-Incorrect Material|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|Vendor related |Material error
ZF|P7000039672|29/08/2014|priority 1 |Q3|Unknown|Unknown|Arranhão na área de vedação|ATCO NOPT NOCO NOTE|1242 - HTS maskinteknikk as|Damage |Damage during transport|SS - Controls -SCM  hyd/mech components|Other hydraulic components|Vendor related |Damage during transport
ZF|P6000108542|09/03/2016|priority 3 |Q3|Unknown|Unknown|283912979Z Failed Leakage Test|NOCO ATCO NOPT NOTE|Failed Leakage Test|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZF|P7000016420|14/07/2011|priority 1 |Q3|Unknown|Unknown|Failure on TPT AR read.|NOTE NOPT ATCO NOCO|MIKROKRETS|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Equipment Malfunction
ZF|P6000042968|26/08/2013|priority 3 |Q3|Unknown|Unknown|Additional endurance test|NOCO ATCO NOTE|EET performed.|Change/Deviation Request |Process substitution request|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement
ZF|P7000000897|24/05/2012|priority 1 |Q3|Unknown|Unknown|Change over com desvios|NOPT ATCO NOTE NOCO|||Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Control Valve|FMC Materials/Stores related |Improper Packaging & Storage
ZF|P7000024191|23/10/2012|priority 2 |Q3|Unknown|Unknown|Coupler de supply fora da revisão atual|ATCO NOTE NOPT NOCO|ECN não implementada|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Other causes/damage |Cause not found
ZF|P6000068770|09/08/2015|priority 2 |Q3|Unknown|Unknown|Non conforming master data  PSM|NOTE ATCO NOCO|Unknown|Documentation |Incorrect user documentation (customer)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000088626|31/07/2015|priority 3 |Q3|Unknown|Unknown|EngineeringErr:Missing earth conductors.|NOTE NOCO NOPT ATCO|Missed to include earth wiring in LST|Design |Specification Error|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |Engineering Error
ZF|P6000074156|17/09/2013|priority 1 |Q3|Unknown|Unknown|(SS) DHI card update issue|NOCO ATCO NOPT NOTE|DHI card update issue|Test Related |OBS-Function|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Equipment Malfunction
ZF|P6000031350|20/03/2014|priority 3 |Q3|Unknown|Unknown|IWIS DHI-board set to wrong baudrate|NOPT NOTE NOCO|Missing MOC at change of baud rate|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|FMC Engineering related |Engineering Error
ZF|100052388|07/03/2013|priority 2 |Q3|Unknown|Unknown|BOM and ICP update on old system scm's|ATCO NOTE NOCO|New part required for each mobilization|Design |DBI Error|SS - Controls -SCM  hyd/mech components|Hydraulic coupler|FMC Engineering related |Continuous Improvement
ZF|P6000107991|22/04/2014|priority 3 |Q3|Unknown|Unknown|no status codes in  Line status|NOPT ATCO NOCO NOTE|Follow-up in QN 200376395|Test Related |OBS-Function|SS - Controls - Electronic Boards|Down Hole Interface (DHI)|Vendor related |Clarification
ZB|7101172|02/11/2009|priority 4 |Q1|STATOIL|NORTH SEA|SCM 19 GFA  J-3H  AI-card SEMB malfunc.|NOTE NOPT NOCO|Power supply failure  DC/DC converter|FMC Other Defect |Functional|SS - Controls - SS Control Module (SCM)|Subsea Electronic Module (SEM)|Vendor related |Material error
ZF|P6000121268|15/10/2014|priority 3 |Q3|Unknown|Unknown|Missing Baseplate|NOCO NOTE NOPT ATCO|Base plate not avaliable on stock|FMC Other Defect |Physical|SS - Controls -SCM  hyd/mech components|Baseplate|FMC Other causes/damage |Planning error
ZF|100020562|02/08/2010|priority 3 |Q3|BP|GOM|Mark all necessary ports on BPTH SCMs|NOTE NOCO NOPT|Mark all necessary ports on BPTH SCMs|Marking |No Marking|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Assy |Lack of Maintenance
ZE|P6000091085|22/08/2016|priority 4 |Q3|Unknown|Unknown|Child CAR - OWIRS Deadman sequence|ATCO NOTE NOCO NOPT|Unknown|Unknown|Unknown|Object Types to Eng Matl CLASS|scm_mkIIE|Variance|Enhance Process
ZB|100027228|01/12/2011|priority 1 |Q1|STATOIL|NORTH SEA|Critical error with E-3H QDV|NOCO ORAS NOPT ATCO NOTE|Unknown|Documentation |Procedure / Process Error|SS - Controls -SCM  SEM el/opt component|SEM mech. Components|FMC Engineering related |Procedure error
ZF|P6000083395|25/04/2012|priority 3 |Q3|TOTAL|Unknown|Test of WLD missing in inhouse procedure|NOPT NOCO ATCO NOTE|Test of WLD missing in In-house / FAT|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Procedure error
ZF|P6000028371|27/01/2009|priority 3 |Q3|SHELL|GOM|short circuit wires on outercan|ATCO NOTE NOCO NOPT|PN fabricated before the MOC approval|Damage |Damage during assembly|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Other causes/damage |QN Cancelled
ZF|P6000080733|01/04/2014|priority 4 |Q3|STATOIL|NORTH SEA|Leakage on Silicone Compensator Bladder|NOTE NOCO ATCO|Leakage in bladder  blister|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Engineering Error
ZF|P6000110380|03/03/2014|priority 2 |Q3|Unknown|Unknown|ESRS610 Failure Alarm during Syst Test|NOPT NOTE NOCO ATCO|No need to open the SCM  continue tests|Test Related |OBS-Function|SS - Controls - Electronic Boards|Eth.net items|FMC Other causes/damage |Cause not found
ZF|P6000042969|24/02/2015|priority 3 |Q3|Unknown|Unknown|Groove/slot dim out of tolerance|NOPT NOTE NOCO ATCO|One part found out of tolerance.|Machining Related |OBS-GD&T (Geometric dimension&tolerance)|SS - Controls -SCM  hyd/mech components|Other mechanical components|Vendor related |Specification not followed
ZF|P7000039672|19/09/2013|priority 1 |Q3|Unknown|Unknown|Vazamento no Manifold block PS#15|ATCO NOTE NOCO NOPT|123643 - BOSCH REXROTH  LTDA|Test Related |OBS-Leakage (Fluid)|SS - Controls -SCM  hyd/mech components|Hydraulic Manifold / Adapter Plate|Vendor related |Final Inspection Error
ZF|P6000065886|03/01/2011|priority 2 |Q3|Unknown|Unknown|Forslag til endring på fremtidige ordre|NOPT NOTE ATCO NOCO|Continuous Improvement|Assembly Related |OBS-Interface issue|SS - Controls -SCM  hyd/mech components|Hydraulic Tubing|FMC Engineering related |Continuous Improvement
ZF|P6000043766|26/05/2009|priority 3 |Q3|PETROBRAS|GOM|Wrong PN and SEM address on nameplate|NOTE ATCO NOCO NOPT|FMC Assy: Operator Error|Assembly Related |OBS-Wrong Part Assembled|SS - Controls - SS Control Module (SCM)|Subsea Control Module (SCM)|FMC Assy |Operator Error
ZB|100017997|20/04/2009|priority 3 |Q1|BP|GOM|WSCM Saltwater Ingress|ATCO NOPT NOCO NOTE|WSCM Saltwater Ingress below EC connecto|FMC Other Defect |Physical|WOCS Control Module (WOCM) Hydraulic|Other WOCM Hydraulic|FMC Engineering related |Engineering Error
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|Class 1 ECN 6083510|NOPT NOCO ATCO NOTE|Class 1 ECN 6083510|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|Unknown|SCM bladder found with defect|ATCO NOTE NOCO|Vendor related: Specification not follow|Test Related |OBS-Leakage (Fluid)|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P7000039672|25/07/2014|priority 1 |Q3|Unknown|Unknown|ECN 6164886 - P7000039672|NOCO NOPT NOTE ATCO|Unknown|Design |DBI Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |ECN Change
ZF|P6000066700|22/08/2011|priority 1 |Q3|HOUSTON STOCKING V2|Unknown|SCM MK II E  150  HOUSTON STOCK V2|NOTE ATCO NOCO NOPT|Wrong config  in ext realer terminat box|Damage |Damage during assembly|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Damaged during testing
ZD|P6000123882|14/01/2015|priority 3 |Q2|Unknown|Unknown|Assy/Hess/SCM/Misprint Nameplate|NOCO ATCO NOTE|Misprint Nameplate|Marking |Marking content error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|Vendor related |Specification not followed
ZF|P7000024191|21/05/2012|priority 1 |Q3|Unknown|Unknown|SRT SCM GLOBAL SN 01|ATCO NOTE NOCO NOPT|Lab test box with problem.|Test Related |OBS-Missed Operation|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Test |Incorrect set up/testing
ZF|100049000|09/03/2011|priority 2 |Q3|BP|GOM|Hydraulic Coupler/Port on SCM|NOTE ATCO NOPT NOCO|Hydraulic Coupler/Port on SCM|Assembly Related |OBS-Interface issue|SS - Controls - Hydraulic Products|Hydraulic Manifold Kit|FMC Other causes/damage |No Non-Compliance
ZF|P6000104114|06/11/2014|priority 3 |Q3|Unknown|Unknown|Mising wires in wiring kit|NOCO ATCO NOPT NOTE|ECN process missed to update stock|Assembly Related |OBS-Assembled Incorrectly|SS - Controls -SCM  SEM el/opt component|SEM cable & wiring|FMC Engineering related |ECN Change
ZF|P6000058949|06/06/2013|priority 3 |Q3|STATOIL|NORTH SEA|Gullfaks drawing|ATCO NOCO NOTE|Information in drawing improved.|Documentation |Procedure / Process Error|SS - Controls - SCM (Subsea Control Modu|SCM (all types of Control Modules)|FMC Engineering related |Continuous Improvement