notification_type|material|defect_date|priority|notification_origin|customer_name|region|notification_status|damage_group_desc|damage_desc|object_part_group_desc_1|object_part_desc_1|cause_group_desc|cause_desc|notification_desc|root_cause
ZF|P6000066700|15/09/2011|priority 1 |Q3|HOUSTON STOCKING V2|unknown info region|NOCO ATCO NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|Missing HC in SCM OKONO|Human error  process not maintained
Q3|7105128|10/10/2003|priority 2 |Q3|TOTAL|unknown info region|NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|GIR-125 SCM S/N 19P no comm SEM B|unknown info root_cause
Q1|7102643|13/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTI|hydraulic|accumulators|defect locations offshore field|transocean searcher|initial direct product problem|damages|SCM 14 ÅsgA R1-H LP Leak in bottom Acc.|Due to overpressurizing on WOCS LP-syste
ZB|P6000039844|11/10/2018|priority 4 |Q1|unknown info customer_name|unknown info region|NOTI OSTS NOPR|project|project requested unfinished shipment|object types to eng matl class|scm|vendor|second tier supplier issue|SCM #6 due for delivery|unknown info root_cause
Q3|7101463|25/06/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|electrical|printed circuit board|defect locations onshore|workshop other|initial direct product problem|function|DHI-failure|unknown info root_cause
Q1|7101172|26/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTI NOPT|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM 20 GFA D-1H PT Func AWV malfunction|unknown info root_cause
ZF|P7000016420|05/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|locking mechanism|qa qs qi|goods receiving inspection error|Bucha -Revestimento não Conforme- P55/09|REVESTIMENTO
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOCO NOPT|electrical|sem powersupply|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 48 ÅsgB J-3H SEM A shortcircuit|unknown info root_cause
ZF|P6000037215|07/06/2011|priority 3 |Q3|ENGIE|NORTH SEA|NOCO ATCO NOPT NOTE|documentation|procedure process error|electric products|other electric products|engineering|procedure error|Short circuit of low amp board to earth|Change in procedure
ZE|P6000084906|12/09/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|other hydraulic components|qa qs qi|operator error|Plastic cover found inside new SCM|SCM not thoroughly checked before closed
ZF|100030542|17/08/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|marking|marking content error|scm|scm|other causes|no noncompliance|Drawing errors found at Final Inspection|Product revision
Q3|100016110|01/05/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Damaged shipping container upon reciept|unknown info root_cause
ZF|100035118|10/02/2005|priority unknown info priority|Q3|ENFIELD|unknown info region|NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM prod # 5  failure of SEM A|unknown info root_cause
ZF|7103233|13/12/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly test|miscellaneous|scm electrical|other scm electrical|other causes|miscellaneous|CSA factory audit of SCMs  4 findings|No manual to comply with CSA
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM S/N 7 I-1H GFA AI card malfunct.SEMB|AI-card on SEM B
Q3|7104670|24/02/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|All SCMs to have hyd. flow restrictors|Instructions from system engineering
Q2|7105128|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO NOTE|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|material|SCM P 01|unknown info root_cause
ZF|P6000110991|20/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extended test
ZF|P6000068912|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100015538|27/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|P6000064909|19/01/2012|priority 2 |Q3|TOTAL|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|Temp sens indicates to high temp (SCM)|Follow-up in SN 300307969
ZF|P6000050867|26/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|function|computer system software|electrical solution sw|engineering|engineering error|FAT stopped due to software problems|FMC Engineering : Engineering Err
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|unknown info region|NOPT NOTE NOCO ATCO|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 27|Damage in warehouse handling
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|assembly test|do not use|fks quality system issues|resource management|assy|missing operation|Not performed HFT do to lack of time|PSM not followed  short mob time
ZF|100048038|16/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOCO NOPT|marking|no marking|common misc fasteners imperial|screw|engineering|engineering error|batch missing|New requirements
ZF|7103234|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|function|scm|sem|other causes damage|qn cancelled|Communication missing|See SN 300160640
ZF|P6000104116|13/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|documentation|procedure process error|scm sem el opt component|other scm sem el opt components|other causes damage|no noncompliance|Mangler risteprofil til DIU|No procedure fault Lack of OPRexperience
ZF|P6000101955|18/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|electronic boards|main boards cpu & i o|other causes damage|qn cancelled|Low voltage during EEtest|Minor impedance-increase  Faston contact
ZF|100037967|20/01/2009|priority 1 |Q3|BP|unknown info region|NOCO NOTE|test|function|scm|scm|test|missed operation|B18 MCM N1 - lost comunication to SEM A|unknown info root_cause
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 04|Software improvement/correction
ZF|P6000104111|10/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage during assembly|scm hyd mech components|baseplate|assy|operator error|Damage base plate|Damaged during dissassembly
Q3|3812476|04/07/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI|electrical|pressure transducer|defect locations offshore field|norne fpso|initial direct product problem|function|SCM Press. transm. faults well C4-H|Refer to QN200008584
ZF|100031193|27/01/2004|priority 2 |Q3|PETROBRAS|unknown info region|NOTE NOCO ATCO NOPT|assembly test|function|scm hydraulic|other scm hydraulic|engineering|design specification drawing error|THE DRAINHOLE IS TOO BIG|Drain hole too large
ZF|100056443|29/11/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|electrical|component failure|scm|scm|other external causes|customer error responsibility|SCM B side DHI Card in-operational|unknown info root_cause
Q3|7102643|27/04/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|electrical|pressure transducer|defect locations offshore field|åsgard a|initial direct product problem|function|Function PT for AWV not working (R-1-H)|Refer to QN 200003653
ZF|100020562|27/10/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM marking labels are peeling off|unknown info root_cause
Q3|7105128|04/08/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM P 01|unknown info root_cause
ZF|P6000088604|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100048038|30/11/2010|priority 2 |Q3|CHEVRON|WEST AFRICA|NOCO NOTE ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P7000024191|28/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm|scm|engineering|continuous improvement|DPT B values|unknown info root_cause
ZF|P6000116166|01/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|physical damage|scm hyd mech components|outer can|assy|damaged during assembly|Bladder in outercan bursded|Silicon bladder changed
ZF|P6000079984|07/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|electronic boards|main boards cpu & i o|engineering|procedure error|Wrong SEM supply voltage reading at ST|Lack of calibr. procedure  ref NRB text
ZF|P6000088614|25/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|machining|hole size error|scm sem el opt component|sem mech. components|vendor|specification not followed|Wedge disc holes are too small|Holes on part not acc. to DWG
ZF|P6000073687|25/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|drawing error|scm|scm|engineering|dwg error|Missing info on GA dwg.|Missing info on GA dwg.ZE QN:200269754
ZF|100048038|10/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|ATCO NOPT NOTE NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|materials stores|improper packaging & storage|SILICONE CONTAMINATION|SILICON CONTAMINATION
ZB|100020562|07/06/2006|priority 2 |Q1|BP|GOM|NOTE NOCO NOPT ATCO|damage|wear & tear|sensors|scm pressure transmitter (pt)|vendor|component error|PT reading for SCSSV B below acceptable|Sensors failed in Control Module
ZF|100017278|18/03/2004|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|design|do not use|scm electrical|dhi pcbs|manufacturing|do not use|DHI-109 problemer|Lack of updated test procedure
Q3|7102643|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|hydraulic|accumulators|defect locations onshore|workshop other|problem causes defect causes|service|Leak from SCM accumulator offshore|Test error (accumulator over pressured)
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTI NOPT NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Marlim SCM 06-ALFA to 06-GAMA|Wrong material
ZF|100064910|25/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|dbi error|scm|scm|engineering|dbi error|Wrong bolts in BOM for SEM el-can.|Incorrect part in BOM/DBI
ZF|P7000024900|15/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|physical|scm|scm|other causes damage|planning error|SOLICITAÇÃO DE CONCESSÃO|unknown info root_cause
ZF|100037966|27/06/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|SCM P9  HFT  PRD voltage clarification|Typo in procedure.
ZF|P7000039672|08/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|imension (tolerance)|common misc fasteners metric|hydraulic manifold adapter plate|intercompany|final inspection error|Vazamento no Manifold Block|FMC Dunfermline124086 PARNOX IND E COM DE ARTIGOS IND L
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Bytting av PT'er.|unknown info root_cause
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE|test|unknown info damage_desc|scm|scm|other causes damage|cause not found|08-MEGI-016: RAM Warning Error|Error Message
ZE|7100320|12/06/2015|priority 3 |Q3|PETROBRAS|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|Queda de SCM Hercules durante instalação|unknown info root_cause
ZB|100054943|10/10/2011|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOTE NOCO|other defect|functional|fks quality system issues|quality management system|other causes damage|planning error|Client notified in short notice|Lack of communication and process
ZF|P6000068924|31/01/2012|priority 3 |Q3|TOTAL|unknown info region|NOTE ATCO NOCO NOPT|test|function|scm|scm|vendor|material error|Current reading outside accept crit.|Corrected by SW-calibration
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOPT NOCO NOTE|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #9 Wiring|BPTH SKOFLO SCM SN #9 Wiring
ZF|P6000105542|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000088626|14/05/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|causes for improvement|documentation|SCM  HCM HFT on BP SD 2 PMA's WF1 & 2|Update of procedure.
ZF|P6000088751|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q1|7102969|unknown info defect_date|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|leakage|LP Control Valve line 11  leaking subsea|Back wall of CV not secured
Q3|100017305|01/11/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|electrical|printed circuit board|defect locations onshore|inhouse fat|initial direct product problem|function|FlowMeter inputs(Counter Interfaces)def.|unknown info root_cause
Q3|7102643|21/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Feil på SCM|unknown info root_cause
Q1|100018531|11/09/2002|priority 3 |Q1|SHELL|unknown info region|NOCO NOTI NOPT ATCO|electrical|sem powersupply|defect locations offshore field|sahara (biju)|initial direct product problem|function|SCM 2 Bijup.& Salema PTCD card malfunct.|unknown info root_cause
ZF|P6000042969|02/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|hydraulic products|coupler|assy|damaged during assembly|Change hydraulic coupler|Sharp edge on Male coupler   test equip.
ZF|100035013|15/10/2010|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO ATCO|other defect|functional|scm|scm|other causes damage|cause not found|O.L. D3 SEM A fiber fault|Transfered to QN 200084493
ZF|P7000008275|24/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|function|instrumentation|scm pressure transmitter|vendor|equipment malfunction|Issue on PT 16.|unknown info root_cause
ZF|P6000084242|15/08/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOTE NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|Rebuild to Copi South Belut from Bawal|Requested rebuilt for new project
ZF|P6000064911|30/11/2011|priority 1 |Q3|TOTAL|NORTH SEA|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|couplers loose on two modules|Couplers were not torqued.
ZF|P7000016420|13/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm|scm|qa qs qi|goods receiving inspection error|Revestimento do Pino Guia|unknown info root_cause
Q3|7102643|30/12/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|product defects for dept.|scm|defect locations onshore|workshop|problem causes defect causes|production personnel|Possible miscoupled wires for LD & LVDT|See long text
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|NOPT NOTE NOCO ATCO|assembly test|function|scm|scm|vendor|vendor design error|HFT ACCEPTANCE CRITERIA NOT MET|HFT DOC. & TEST UNIT DISCREPANCY
ZF|P6000050867|28/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|scm|scm|engineering|ecn change|Upgrade with new software|Product update
ZD|100049000|20/07/2007|priority 1 |Q2|BP|unknown info region|NOPT ATCO NOCO NOTE|marking|marking content error|scm|scm|vendor|assembly error|Incorrect Nameplate SEM Markings|Incorrect SEM address on SCM nameplate
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|unknown info region|NOTE NOPT NOCO ATCO|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 29|Damage in warehouse handling
ZF|100048038|21/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|ATCO NOTE NOPT NOCO|change deviation request|part substitution request|scm|scm|other external causes|customer error responsibility|Change of restrictors|FMC Houston - restrictor size change
ZF|P7000008275|27/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|leakage (fluid)|scm hyd mech components|compensator|assy|operator error|Vazamento de silicone pelo strainer|unknown info root_cause
ZD|P6000084242|08/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PARTNUMBER|INCORRECT PARTNUMBER
ZF|P7000001621|24/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|cleanliness|hydraulic products|compensator|vendor|specification not followed|Compensador fora da classe de limpeza.|Classe limpeza acima do especificado
ZF|P6000108984|14/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|specification error|computer system software|sem tpu config|engineering|engineering error|Wrong in configuaration file BAYU UNDAN|unknown info root_cause
ZF|P6000145982|20/04/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|electronic boards|dhi|software|other specify in comments|SEM  DHI issue during EFAT test|Board loose data on power loss.
ZF|100056443|03/04/2017|priority 3 |Q3|EDISON/EDF|NORTH SEA|NOTE NOCO|damage|damage from corrosion|scm sem el opt component|sem cable & wiring|other causes damage|cause not found|Uncontrolled DCV operations|Followed up on ZE Qn 200533520
ZF|100036936|20/03/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|assembly test|assembled incorrectly|scm|scm|other causes|logist.handling packing shipping error|Missing filters seawater compensator SCM|No external inspection before transport
ZF|P6000039844|06/05/2009|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO NOPT|test|function|scm|scm mounting base (scm|vendor|unknown info cause_desc|Communication problems in hyperbaric|Error to be confirmed in QN200124450
Q3|7100320|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM SN 08|Wrong materials
ZF|P6000064909|14/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|documentation|procedure process error|electronic boards|power units|engineering|specification error|Spec error: Wrong temp sensor position|Human failure  misunderstanding
Q2|7105130|28/11/2000|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|electrical|sem powersupply|defect locations onshore|inhouse fat|initial direct product problem|function|SCM M 06|unknown info root_cause
ZF|P6000107981|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7105128|12/12/2001|priority 3 |Q3|TOTAL|unknown info region|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations offshore field|girassol fpso|initial direct product problem|leakage|SCM HP leak SCSSV Girassol S/N 4|unknown info root_cause
ZF|P7000008275|05/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|interface issue|scm hyd mech components|other mechanical components|other causes damage|planning error|Top plate TBU SN 05 danificada|unknown info root_cause
ZF|100048038|31/03/2007|priority 1 |Q3|AGBAMI|unknown info region|ATCO NOCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|component error|Check valve - High leak|scratch on the surfice inside the valve
Q3|7104670|14/04/2000|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|electrical|printed circuit board|defect locations onshore|efat|initial direct product problem|function|Short circuit on Sand Detector|SIO card
ZF|P6000073613|13/05/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|specification error|scm sem el opt component|sem cable & wiring|engineering|specification error|we have get wrong pn and w15L is marked|Fault in BOM  update part nr
ZF|100033987|07/10/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTE NOCO|assembly test|handling damage|scm electrical|wiring|engineering|design specification drawing error|Damage to COV and wiring|Interference outer can / COV & wiring
ZF|P6000042968|20/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|electric products|electrical harness|vendor|clarification|AI Ch. 10 don`t work during testing|Follow-up covered by QN200192345
ZF|100030711|14/03/2014|priority 2 |Q3|STATOIL|unknown info region|NOTE NOCO|test|function|scm|scm|other causes damage|no noncompliance|CPU card revision Level|Current SW will work for new (Rev J) HW
ZF|P7000039672|20/04/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|damage|damage from corrosion|scm hyd mech components|other mechanical components|vendor|final inspection error|Extension Rod oxidada|unknown info root_cause
ZF|P6000121958|13/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|machining|thread error|scm hyd mech components|hydraulic manifold adapter plate|engineering|dwg error|Pt 62 has wrong threads|Drawing error
Q3|7105129|03/10/2003|priority unknown info priority|Q3|TOTAL|unknown info region|NOPT NOCO ATCO NOTE|mechanical|locking mechanism|ext. loc. luanda (angola)|work shop|unknown info cause_group_desc|unknown info cause_desc|SCM 06 SCM 06 Wo/DHI Damaged Ext Rod|Not  yet found  to be stated.
ZF|P6000028371|11/04/2008|priority 3 |Q3|SHELL|GOM|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|engineering|unknown info cause_desc|Batch numbers missing in iBASE list|Change: batch cert. to batch management
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOTE NOCO ATCO NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #20 Wiring|BPTH SKOFLO SCM SN #20 Wiring
ZF|100049000|12/10/2010|priority 3 |Q3|BP|GOM|NOCO NOTE NOPT|test|missed operation|scm|scm|test|operator error|Dropped below 2% pressure drop|Not noticed during pressure test
Q3|3794920|16/01/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|design specification error|DHI-problemer|Power Supply 24V
ZF|P7000024900|24/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
Q1|7102643|unknown info defect_date|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|product defects for dept.|scm|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|Connector EC2 is mounted 90 deg. wrong|Assembly error
ZF|7103233|06/01/2006|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|missing operation|Leaking SCM Production.|Leaked onbord  no leak during test at Ko
Q2|100016711|15/01/2003|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|electrical|sem el.rack|ext. loc. kos houston|work shop|initial direct product problem|function|SEM A 12 VDC converter failed|unknown info root_cause
ZF|P6000043122|07/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|test|function|instrumentation|scm flowmeter|test|damaged during testing|Flow meter not working|Contamination in control system
ZF|P6000074156|03/04/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|electronic boards|dhi|vendor|design error|Dhi 204|All eight DHI204 with erratic FW  traced
ZF|100054943|04/10/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation requirement|missing certificates records|scm|scm|documentation requirement|input requirements missing|Vincent OH09 OH & SEM615 Incomplete MRB|unknown info root_cause
ZF|P7000000897|06/10/2016|priority 1 |Q3|SHELL|unknown info region|NOPT ATCO NOCO NOTE|test|function|scm hyd mech components|control valve|assy|operator error|MMR - Change Over HP with reversed link|unknown info root_cause
ZF|P6000080343|30/09/2013|priority 4 |Q3|TULLOW|WEST AFRICA|ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|MMRSCM Jubilee SN2  Leakage|Leakage likely caused by particles
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZB|100016901|28/04/2010|priority 3 |Q1|SHELL|GOM|ATCO NOTE NOCO|damage|damage from corrosion|scm electrical|other scm electrical|other causes damage|no noncompliance|EC connector sealing faces corroded|EC connector sealing faces corroded
ZF|7102969|07/03/2006|priority 3 |Q3|EXXONMOBIL|unknown info region|ATCO NOPT NOTE NOCO|assembly test|interface of components issue|scm|scm|vendor|fabrication error|INTERFACE ERROR|BLADDER NIPPLE THREAD LENGTH EXCESSIVE
ZF|P6000063531|09/04/2018|priority 3 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|software|program configuration|object types to eng matl class|scm|software|other specify in comments|Cancelled|Unknown
Q3|7104033|19/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|Silicon leak on compensation system SCM|unknown info root_cause
ZF|100049000|18/12/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|change deviation request|part substitution request|electronic boards|other eletronic boards|other causes|no noncompliance|BP instruction for AI150 card upgrade|Customer instruction
ZF|P7000000229|10/02/2015|priority 1 |Q3|CHEVRON|unknown info region|NOCO ATCO NOTE|test|missed operation|scm|scm|test|missed operation|MMR - Process error|Missed Operation
ZF|100030542|23/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|other defect|physical|scm hyd mech components|other hydraulic components|materials stores|improper packaging & storage|Too high temperature causing failures.|Temperature too high in workshop
ZF|P7000001843|04/11/2014|priority 1 |Q3|PETROBRAS|unknown info region|NOTE NOCO ATCO|assembly|interface issue|scm|scm|assy|operator error|MMR - Hyperbaric Setup|unknown info root_cause
ZF|100056261|06/03/2008|priority 2 |Q3|MURPHY|WEST AFRICA|NOPT NOCO ATCO NOTE|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000031350|16/04/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|test omitted|scm|scm|test|missed operation|He leak test not performed iaw process|communication problems in workshop.
ZF|P6000062454|05/12/2011|priority 3 |Q3|DAEWOO|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|test|operator error|Verify test equipment  HPU/SCMTS|Damage during incorrect testing
ZE|P6000103208|17/10/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|electrical|design error|(E) - SCM Communication Issues|unknown info root_cause
ZF|100048038|20/03/2012|priority 3 |Q3|CHEVRON|WEST AFRICA|NOCO NOTE NOPT ATCO|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|no noncompliance|PIV  PT and SEM Temp Anomaly Readings|PIV  PT and SEM Temp Anomaly Readings
ZB|100020278|12/05/2010|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE ATCO|test|component error|scm hydraulic|other scm hydraulic|test|damaged during testing|SCM comm's fault found during CDT|SCM comm's fault found during CDT
ZF|P7000001621|27/07/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|function|scm el opt components|other el opt components|materials stores|improper handling|MMR - Falha de leitura de PTs internos|unknown info root_cause
ZF|P6000091085|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000064909|13/04/2012|priority 4 |Q3|TOTAL|NORTH SEA|NOCO NOPT NOTE|documentation|procedure process error|computer system software|network config|intercompany|kongsberg|We did not get communicaton with the SCM|SCM was sent back to the workshop
ZF|P6000101955|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000104111|08/06/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Egina WC 0020 SCM PT failure MIV1|unknown info root_cause
ZF|7102643|23/02/2004|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic control valves|assembly test|operator error|FAIL WITH VALVE HP|SCM return overpressurised
ZF|100034440|05/04/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly test|missed operationassy test|scm|scm|materials stores|improper handling|Re-test of  Accumulator on MKIV|Acc. not available when perf. press test
ZB|7104670|07/12/2010|priority 4 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTE|change deviation request|raw material substitution request|customer compliant|noncompliance to customer requirement|engineering|specification error|F&D Recall the backup SCM|unknown info root_cause
ZD|P6000028371|15/09/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage due to handling|scm hyd mech components|outer can|vendor|operator error|Damage EC|damage ec
ZF|3794920|19/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|documentation|missing certificates records|scm|scm|materials stores|operator error|Batch numbers missing|unknown info root_cause
ZF|P1000018406|03/02/2009|priority 1 |Q3|BP|GOM|NOTE NOPT NOCO ATCO|test|function|sensors|scm flowmeter|vendor|equipment malfunction|DFCM will not build pressure|DFCM will not build pressure
ZE|100046112|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Angel - SCM Issue|SCM Issue
ZF|P7000001621|14/10/2013|priority 1 |Q3|PETROBRAS|unknown info region|NOCO NOPT ATCO NOTE|test|function|electronic boards|dhi|other causes damage|cause not found|MMR - DHI 1 SEM A NÃO COMUNICA|unknown info root_cause
ZF|P6000063531|22/10/2014|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|Vigdis VEPIII rebuild flowmeter| F.M. not reading minimum flow
Q3|7101172|02/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|product defects for dept.|flow control module|defect locations offshore field|gullfaks a|initial direct product problem|function|CIDV supply pressure drops  well H-1H|unknown info root_cause
ZF|7105129|18/08/2003|priority 3 |Q3|GIRASSOL OPTION|unknown info region|NOTE NOPT NOCO|assembly test|documentation general|scm electrical|other scm electrical|engineering|design specification drawing error|INCORRECT ASSEMBLY|Error in configuration engineering
ZF|100048038|17/12/2006|priority 1 |Q3|CHEVRON|unknown info region|NOCO NOPT NOTE ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|component error|POD LEAKING AT RELIEF VALVES|Vendor-Component Error
Q3|100013155|23/01/2001|priority 3 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|NOCO NOPT NOTI ATCO|hydraulic|hydraulic control valves|defect locations onshore|tank test|root cause engineering|test procedure error|Control valve test results out of limits|No fault found. Procedure to be changed
ZF|100017997|13/09/2006|priority 3 |Q3|BP|unknown info region|NOTE NOPT ATCO NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|missing operation|Leakage   Water in silicone.|interface connection leak
ZF|100038200|05/08/2011|priority 2 |Q3|SHELL|unknown info region|NOCO NOTE NOPT ATCO|damage|damage from corrosion|electric products|electrical connector|assy|damaged during assembly|Perosity in the Welds of EC Seal Surface|Perosity in the Welds of EC Seal Surface
ZF|P6000122574|19/07/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Missing information in Documentation|unknown info root_cause
ZF|100050383|11/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|project|project requested unfinished shipment|scm|scm|projects|customer error|Company decide to not upgrade el.boards|unknown info root_cause
ZF|P7000039672|27/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|wrong part assembled|instrumentation|scm pressure transmitter|vendor|wrong part delivered|Wrong Pressure transducer delivered.|SCANSENSE - PO 47456838
ZF|P6000104111|16/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|function|scm|scm|other causes damage|no noncompliance|Lost communication to CPU in burn in|Failure in test equipment
ZF|P7000039672|08/03/2017|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO DLFL|design|dbi error|object types to eng matl class|clamps_common|other causes damage|qn cancelled|ECN 6209019 - P7000039672 - CDM|CORRECTION OF PART NAME ON DBI. DURING L
ZF|P6000088604|14/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|scm|scm|engineering|dbi error|dokuneent is not correct|Incorrect linking in DBI/DWG
ZF|P6000105542|30/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|missing certificates records|mla raw material|forgings|qa qs qi|goods receiving inspection error|Removal of SCM interchangeability|Removal of SCM interchangeability
ZF|100006609|12/04/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage from corrosion|scm|scm|assy|damaged during assembly|Conexão presa a rosca|Degradação submarina
ZF|100037965|30/11/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|component error|scm electrical|processor pcbs|test|damaged during testing|No communication with Sem A or Sem B|Transformer failure caused short circuit
ZF|P7000039672|08/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|damage|damage during assembly|scm hyd mech components|control valve|assy|damaged during assembly|DCV low pressure inoperante|unknown info root_cause
ZF|P6000107981|10/07/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|outer can|vendor|specification not followed|Check valve on outercan is skewed.|OC check valve interface not askew
ZF|P6000069820|09/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring fault on CVHP22 and CVHP23|Wrong wiring  human error.
ZF|100036936|20/09/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|assembly test|interface of components issue|electronic boards|other eletronic boards|other causes|no noncompliance|Problem with connecting MFM|No error in SCM  Simulator is corrected
Q3|7102643|24/02/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|All SCMs to have hyd. flow restrictors|Instructions from system engineering
ZF|P6000108984|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|13/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|interface issue|instrumentation|scm pressure transmitter|vendor|final inspection error|PT does not fit on Manifold Block|unknown info root_cause
ZF|P6000109194|27/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|LP Return Flowmeter not working properly|Unstable readings  follow-up QN200369178
ZF|P6000121958|25/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|machining|inside diameter error|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Wrong hole size in manifold block|Machined M8 threads  specified M10
ZF|P6000069056|13/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000067533|08/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|materials stores|improper packaging & storage|SCM Modules stored outside with no PSM|Improper Storage
ZB|P6000063531|11/09/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOPR OSTS NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Bad jumper connector or socket|unknown info root_cause
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000104112|19/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|imension (tolerance)|scm hyd mech components|other mechanical components|assy|damaged during assembly|diam out of tollerance|Diam out of tolerance
ZF|P6000077632|04/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|missed operation|electronic boards|dhi|test|operator error|FAT parcially done w/o Proj DLL|Wrong DLL loaded at the begining.
ZD|100038200|18/06/2011|priority 3 |Q2|SHELL|unknown info region|ATCO NOPT NOCO NOTE|damage|damage during assembly|scm hyd mech components|outer can|intercompany|kongsberg|Contamination/Perosity in Welds|Contamination/Perosity in Welds
ZF|P7000000897|23/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|other defect|functional|electronic boards|power units|vendor|equipment malfunction|OTFF board out of work|No 24 voltage on output
Q3|7103233|14/03/2001|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|hydraulic|hydraulic control valves|ext. loc. st.johns (canada)|work shop|root cause engineering|test procedure error|Suspect SCM HP rtn was over pressured|FMC test procedure error has damaged SCM
ZF|100017278|11/03/2008|priority 4 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|design|specification error|electric optical jumpers|electric flying lead|other causes damage|no noncompliance|Jumpers did not reach parking recept|Unknown reason for failure
Q3|7104670|24/09/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM 06 Heidrun Possible SIO-failure|unknown info root_cause
ZF|100051269|10/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|marking|marking content error|scm|scm|engineering|engineering error|Incorrect drawings during SCM Final Insp|incorrect marking on drawings
ZF|100029564|05/09/2016|priority 3 |Q3|PETROBRAS|unknown info region|OSTS NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MMR - Absence of Shackles|unknown info root_cause
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|ECN 7058839 - P7000017839
ZF|P7000039672|17/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|physical damage|scm hyd mech components|baseplate|other causes damage|damage during transport|Arranhão na Base Plate|1756 - UVDAL MASKINFABRIKK A/S
ZF|100037965|22/08/2005|priority 3 |Q3|BP|unknown info region|NOTE ATCO NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|hydraulic products|coupler|vendor|fabrication error|HYDRAULIC COUPLER HC 1 IS LEAK|unknown info root_cause
ZF|P6000029772|27/08/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|design|unknown info damage_desc|scm|scm|vendor|design error|Hose clip on Opt. con. must be changed|See ZF-QN 200137582
Q3|7102969|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|scm rcm|scm|defect locations onshore|inhouse fat|initial direct product problem|documentation|Feil i Hyperbaric-test.TPR-0010405|unknown info root_cause
Q3|7104033|04/07/2002|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|Flowmeter ?|unknown info root_cause
Q2|7104075|12/07/2000|priority 2 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|electrical|printed circuit board|defect locations onshore|fat|initial direct product problem|function|Elektronikk B feilet etter SCM er fylt.|Elkort feilet
ZD|100055600|21/09/2011|priority 3 |Q2|REMINGTON OIL AND GASHOUSTON STOCKING SCM MK II (15K)|unknown info region|NOCO NOPT ATCO NOTE|coating plating|coating defect|scm hyd mech components|outer can|vendor|specification not followed|Outer Can sandblasting|Outer Can Sandblasting
ZF|100046112|19/05/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|No information in test procedures.|Procedure error
ZE|P6000090632|25/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|scm hyd mech components|other hydraulic components|variance|enhance process|Variance in flow restrictors|Improve naming and tolerances
ZF|100037966|22/03/2008|priority 1 |Q3|BP|unknown info region|NOTE NOPT NOCO ATCO|damage|wear & tear|scm|scm|other causes damage|cause not found|FPSO NCR 26 - SCM Failure|unknown info root_cause
ZF|P6000039844|22/08/2018|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|electrical|other specify in comments|object types to eng matl class|scm|test|incorrect set up testing|Missing test equipment / CR request|unknown info root_cause
ZB|100017278|14/09/2008|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|change deviation request|unknown info damage_desc|scm|hydraulic valves|other causes damage|unknown info cause_desc|Leakage in solenoide valve in SCM|unknown info root_cause
ZF|P6000065886|10/02/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|specification error|electric products|electrical harness|engineering|specification error|DHI107 not working Sem B  SCM wiring err|Human failure  checklist not followed
ZB|100030542|15/05/2009|priority 3 |Q1|BAOBAB|unknown info region|ATCO NOTE NOCO NOPT|documentation|procedure process error|scm|sem|other causes damage|unknown info cause_desc|Delay in sending of SCM RAM chip lettte.|Slow process of product defect notice.
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|unknown info region|NOTE NOCO|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips inside the HP-Config Plug|Cleanliness requirement not followed.
ZF|100035013|15/10/2010|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO|test|missed operation|scm|scm|materials stores|operator error|Material not delivered to plant|unknown info root_cause
ZE|P6000145982|21/11/2018|priority 3 |Q3|unknown info customer_name|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM  Damaged MRM/LNCT Card|unknown info root_cause
Q3|7104075|11/05/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTI|hydraulic|hydraulic control valves|defect locations onshore|tank test|initial direct product problem|function|LP supply line subjected to 276 bar|Check valve installed wrong way round
ZF|100035118|18/02/2005|priority 3 |Q3|PETRONAS|unknown info region|NOPT ATCO NOTE NOCO|assembly test|function|scm|sem|vendor|component error|SCM FAILED DURING X-TREE FAT|Power unit failure  24V output.
Q3|7101172|21/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOPT NOCO|hydraulic|hydraulic control valves|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM hydraulic leak  ca 18 l/d  well H-1H|Leaking control valve
ZD|P6000068902|05/10/2011|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|machining|burr chips|electric products|electrical protection cap|vendor|specification not followed|Protector Cover for PT and valves|PT covers full of plastic burrs & chips
Q3|7102643|11/09/2001|priority unknown info priority|Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTI|scm rcm|scm|defect locations offshore field|åsgard a|root cause assembly test|workshopassembly test error|EPROM SW-failure alternativly prog.SEM B|unknown info root_cause
ZF|P6000065528|14/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm|scm|other causes damage|no noncompliance|Ethernet test outside criteria|No SCM deviation  error in TestSt wiring
ZE|7103905|30/03/2007|priority 2 |Q3|FPS-PRODUCT & SYSTEM SALE - ABERDEEN & D|unknown info region|NOTE ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|accepted &|accepted|SCM LP Acc. charging fitting discrepency|Valve changed on Accumulator
ZF|P7000024191|11/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|Furos da Protection Ring fora de centro|Peça ovalizada
ZF|P6000063531|27/12/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000105542|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|NOTE ATCO NOPT NOCO|assembly test|do not use|scm|sem|vendor|component error|SO due to DC/DC Issue on AI150 card|Component Failure/Poor Workmanship
ZF|7103233|24/08/2011|priority 2 |Q3|SUNCOR|unknown info region|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|scm hyd mech components|hydraulic fittings|assy|missing parts|Missing bolts and leaking SCM|unknown info root_cause
ZF|P6000098616|15/10/2013|priority 1 |Q3|SHELL|unknown info region|NOCO ATCO NOPT NOTE|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|MMRSCM Shell SN 422 Outercan Coating|Faded spot painting after hyperbaric
ZB|100036936|18/02/2009|priority 4 |Q1|STATOIL|NORTH SEA|NOTE NOCO ATCO NOPT|test|component error|scm|scm|other causes damage|damage during transport|F&D Problems with communication Sem A|SCM did not work as intended
ZF|P6000037365|04/07/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|leakage (fluid)|scm|hydraulic valves|vendor|specification not followed|Too high leakage on control valve|High leakage during testing
ZF|P6000088751|03/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm|scm|vendor|clarification|Problems with eth. connection on EC3|Follow-up covered by QN 200290318
ZF|100018531|04/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|instrumentation|other scm instruments|other causes damage|damage from wear and tear|Sensor 4-20 mA readings issue|Reading out of acceptance criteria
ZF|7105597|21/10/2010|priority 2 |Q3|PETRO SA  MOSSEL BAY|unknown info region|NOTE NOCO|documentation|procedure process error|scm mech w mb|locking mechanisms|projects|documentation error|Material not delivered to plant|unknown info root_cause
ZB|P6000029772|11/10/2011|priority 1 |Q1|ENGIE|NORTH SEA|ATCO NOTE NOCO NOPT|assembly|assembled incorrectly|scm sem el opt component|optical penetrator (insert)|vendor|assembly error|Gjøa Claim 046 SRM SN 4 & 5|Batch of leaking fibrepenetrators
ZF|P7000000897|04/10/2011|priority 1 |Q3|SHELL|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|packaging handling|Danos na área de vedação.|Uvdal
ZF|P7000008275|25/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|machining|inside diameter error|scm hyd mech components|outer can|machine shop personnel|operator error|Center tubing com erro TBU #01|SCM MMR
ZF|P7000039672|23/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|equipment malfunction|Solda da adapter plate LP danificada|BOSCH REXROTH - 123643 - PO 47586275-6
ZF|100025661|14/07/2006|priority 3 |Q3|SHELL|GOM|NOPT NOTE NOCO ATCO|damage|damage during assembly|scm|scm|vendor|assembly error|DAMAGE TO EC CONNECTORS|DAMAGE TO EC CONNECTORS
Q3|7100320|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM 15|Wrong material
ZF|100037966|21/03/2007|priority 3 |Q3|BP|unknown info region|NOCO NOPT NOTE ATCO|assembly test|function|scm|scm|vendor|equipment malfunction|SCM Pressure sensor show incorrect data|awaiting results of failure investigatio
Q3|7103233|16/02/2001|priority 4 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|ATCO NOPT NOTI NOCO|electrical|pressure transducer|ext. loc. kos houston|work shop|root cause vendor|design error|SCM PTs to be upgraded/tested|Supplier design error
ZF|P6000104111|25/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100049000|25/09/2007|priority 2 |Q1|BP|GOM|ATCO NOTE NOCO NOPT|assembly test|function|control system topside electrical eq.|other control syst. topside el. equip.|vendor audit|unknown info cause_desc|SEM A failed to restart.|SCM need to be sent back to Norway.
ZF|7105128|06/03/2004|priority 2 |Q3|TOTAL|unknown info region|NOCO ATCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic control valves|other causes|miscellaneous|SCM 15P from GIR 102 LP A Leak|Overpressurisation of LP A during WO.
ZB|100066325|09/04/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOCO DLFL|test|function|scm|scm|other causes damage|cause not found|Cancelled|unknown info root_cause
Q3|100018600|06/02/2003|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause assembly test|workshopassembly test error|Fluctation of external sensor readings|Test cable caused crosstalk
ZF|100018820|13/06/2003|priority 3 |Q3|EXXONMOBIL|NORTH SEA|ATCO NOCO NOTE NOPT|service maintenance|unknown info damage_desc|standard components norway|fixing device|vendor|material error|LEAKAGE  IN HP LINE|Brocken bolt in SCM Manifold Block
ZF|P7000001621|07/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|interface issue|scm|scm|purchasing|purchasing error|Parafusos menores que os especificados|unknown info root_cause
Q3|7105597|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|product defects for dept.|scm|defect locations onshore|efat|initial direct product problem|material|Center lock damage.|unknown info root_cause
ZF|100030665|20/03/2013|priority 1 |Q3|SHELL|unknown info region|NOPT NOCO ATCO NOTE|test|function|scm hyd mech components|locking mechanism|other causes damage|cause not found|MMRSCM Pierce 16 SEM Bracket|Torque applied by customer is uncertain
ZF|100037427|06/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm|scm|other causes damage|no noncompliance|DHI 113 functionalty Rosa Capital Spare|IgnoreStatusFlag-Doc.update QN200323348
ZF|P6000105542|12/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100020562|31/01/2007|priority 2 |Q1|BP|GOM|NOCO NOPT NOTE|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|PT reading for SCSSV B below acceptable|PT reading for SCSSV B below acceptable
ZF|P7000039672|30/03/2016|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|Vazamento no Manifold Block|unknown info root_cause
ZD|100016901|20/05/2010|priority 2 |Q2|SHELL|GOM|ATCO NOCO NOPT NOTE|machining|burr chips|scm|scm|vendor|specification not followed|Surface rusted and holes filled|Surface rusted and holes filled
ZD|P6000114972|27/05/2014|priority 3 |Q2|ANADARKO|GOM|ATCO NOTE NOPT NOCO|marking|no marking|scm|scm|other causes damage|qn cancelled|Marking|See Attached email.
ZF|P7000024191|04/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Possível obstrução da linha de retorno|unknown info root_cause
ZF|P6000079433|09/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|test and transportation|sensor simulator (sesi)|test|incorrect set up testing|DHI simulator not working properly|Old SMART-TOOL config file used
ZF|P7000008275|10/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN NUMERO 7047483  _ PN P700013324|ECN
ZF|7103234|04/01/2012|priority 2 |Q3|SUNCOR CPI|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Material not delivered to plant|unknown info root_cause
ZF|P6000043122|25/08/2009|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|design|dbi error|scm|scm|engineering|engineering error|Documentation must be updated|BOM is correct already
ZF|P7000024191|01/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|missed operation|scm|scm|test|incorrect set up testing|Testado em desacordo com o Procedimento|unknown info root_cause
Q3|7104670|07/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|function|SCM failed in operating choke to closed|Control Valve Leaking?
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #10 Wiring|BPTH SKOFLO SCM SN #10 Wiring
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 25|Investigate Coupler Rotation-BPAT SCM 25
ZB|3812476|29/07/2010|priority 3 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|F&D23 Wrong orient. of SCM in skid|SCM not correctly install on the transp
ZF|P7000000897|01/09/2017|priority 3 |Q3|SHELL|unknown info region|NOCO NOTE NOPT ATCO|assembly|over torqued|scm hyd mech components|hydraulic coupler|assembly|over torqued|MMR - Broken Coupler Return line HC 61|Coupler Broke due to Assembly Failure
ZF|100026328|26/04/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|leakage (fluid)|scm hyd mech components|compensator|intercompany|kongsberg|MMR - Leakage through Strainer|unknown info root_cause
ZF|P6000116166|19/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring fault CAN-bus|Wiring error by technician
ZE|P6000091085|13/05/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO DLFL OSTS NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Child CAR - OWIRS Deadman sequence|unknown info root_cause
ZF|P6000093498|05/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|function|scm|scm|engineering|engineering error|Cell voltage out of balance|SW error in previous revision
Q3|7105128|23/11/1999|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|mechanical|locking mechanism|defect locations onshore|montasje|initial direct product problem|leakage|SCM P 03|Locking mech. center rod  O-ring leaking
ZF|3812695|30/04/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly test|material faulty|scm mech w mb|other scm mechanical|engineering|design specification drawing error|CHANGING BOLTS|Change of 12.9 EZ with 12.9 uncoated.
ZF|100020562|31/10/2005|priority 3 |Q3|BP|GOM|NOTE NOCO ATCO NOPT|design|user documentation procedures|scm|scm|vendor|vendor design error|Thunderhorse HFT document errors|Thunderhorse HFT document errors
ZF|100025661|23/04/2003|priority 3 |Q3|SHELL|GOM|ATCO NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|HC51 & HC52 marked opposite of dwg.|unknown info root_cause
ZF|P6000064911|14/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|dbi error|scm|scm|engineering|dbi error|loose couplers on SRM|Incorrect couplers in BOM
ZF|100056176|16/01/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|documentation|missing certificates records|scm|scm|other causes|no noncompliance|missing batch numbers|change to batch management
ZE|100056443|25/01/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|VEGA HFT60041111 3.9.11 DHI card(DHI204)|Improve procedure
ZF|100036232|18/05/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|scm|scm|other external causes|customer error responsibility|Cust Con - Protector Caps|Customer requirement
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|purchasing|unqualified vendor used|SCM Ruptured Bladder (CNR Baobab)|unknown info root_cause
ZF|P6000069056|15/08/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|raw material|defects in material|scm hyd mech components|outer can|vendor|material error|A small crack on the outercan flange.|Crack in Outercan flange
ZF|P6000055213|05/07/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|assembly|assembled incorrectly|hydraulic products|coupler|assy|damaged during assembly|Change hydraulic coupler|Sharp edge on Male coupler   test equip.
ZE|P6000105542|25/01/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|test|wear and tear|Safe Transport declaration - text colour|unknown info root_cause
ZF|P7000039672|29/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|assembled incorrectly|scm sem el opt component|sem mech. components|intercompany|kongsberg|Missing O-Ring from top/bottom WedgeDisk|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000102554|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100001156|18/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|ss compl. & w.over xt r. tools|xmas tree running tool for cxt|other causes|do not use|SCM 15 GFA M-3H AI-card SEMB|No error in AI150 detected
ZB|7104033|08/05/2007|priority 2 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|damage|damage during assembly|scm|scm|other external causes|customer error responsibility|Bursted silicone bladder on SCM for mob|Customer resp. Storage error
Q1|100015538|04/05/2001|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Pressure Transducers & Hydr.Couplers|unknown info root_cause
ZF|P7000016420|30/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Manifold Block P55-09|Bosch - manifold block
ZF|P6000093498|31/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|design|specification error|scm|scm|engineering|engineering error|Error in wiring list|Wiring list error (human mistak)
ZF|P6000068902|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000042968|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|NOTE NOPT ATCO NOCO|assembly|assembled incorrectly|scm|sem|engineering|specification error|SCM to be upgraded acc. to DRM60046044/A|Designe error
ZF|P6000104115|23/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|assembled incorrectly|scm hyd mech components|sem bracket|vendor|clarification|Wrong drilling of center hole of trafo|Follow-up against vendor by QN 200384061
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|repair|Shell control module # 3|See description
ZF|100037130|06/12/2004|priority 1 |Q3|BOURI  FEAD|unknown info region|NOPT ATCO NOTE NOCO|assembly test|handling damage|scm mech w mb|other scm mechanical|assembly test|miscellaneous|Leakage of hydraulic oil in EFAT area|SCM sprayed with Brayco in workshop
ZF|P6000058949|14/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|damage|wear & tear|scm hyd mech components|hydraulic fittings|assy|damaged during assembly|CF leakage on accumulator on SCM|Seal in bottom of accumulator leaking.
Q3|7104075|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|electrical|printed circuit board|defect locations onshore|workshop other|initial direct product problem|material|Kort som ikke er kjørt i burn-in.|Ombyttning unner test
ZF|100034440|25/04/2006|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly test|assembled incorrectly|scm|scm|other causes|qn cancelled|Corroded missing catodic protection|new system replacing present MK4 system
ZD|100049000|02/07/2008|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|documentation|missing certificates records|scm|scm|vendor|specification not followed|No DBI referencing this material|Missing Documentation
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
ZF|100027228|23/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|design|material master error|scm|scm|engineering|dbi error|BOM/DWG need update|unknown info root_cause
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTI NOPT ATCO|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 08 ÅsgA G4-H PT LP Func. malfunction|unknown info root_cause
ZF|P6000098616|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations onshore|fks adm.|initial direct product problem|documentation|Rette opp underlag DWG-212820 rev. B|unknown info root_cause
Q1|7104075|27/12/2000|priority unknown info priority|Q1|SHELL|GOM|ATCO NOTE NOCO NOPT|electrical|pressure transducer|defect locations offshore field|shell alliance gom|root cause vendor|assembly fabrication test error|Faulty Pressure transmitter|Manufacturing defect
Q3|7105597|21/03/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|function|Lost comms. with SCM during bad weather|SCM damaged during workover
Q3|100025735|03/01/2003|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|electrical|sem el.rack|defect locations onshore|workshop other|root cause assembly test|workshopassembly test error|On the ETU no data was read from Annulus|unknown info root_cause
ZF|P6000068924|03/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|damage|damage during testing|scm|scm|test|improper handling|Short circuit when operating EC3|Improper handling of test cables
ZF|P6000122626|24/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|physical damage|scm|scm|other causes damage|shelf life expiry|Bad O-ring|O-ring possible long storage time
ZE|P6000105542|18/09/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|accumulator|causes for improvement|documentation|Pressure procedures need to be update|Improvement of procedures
ZB|100052134|28/11/2007|priority 2 |Q1|PETROBRAS|GOM|NOTE NOCO ATCO|damage|wear & tear|scm hydraulic|other scm hydraulic|other causes|no noncompliance|COVLP Low Pressure Change Over Valve|unknown info root_cause
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
Q3|3787102|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|unknown info notification_desc|unknown info root_cause
ZF|100046112|24/07/2006|priority 2 |Q3|WOODSIDE|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|scm|sem|vendor|component error|ASD does not respond on SEM B.|Error in SIO150 board
ZF|P6000064909|30/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|physical|scm|scm|engineering|continuous improvement|Missing serial nr profile in SAP ?|s/n profile to be implem.  => QN20021167
ZF|7104033|02/10/2006|priority 4 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other external causes|customer error responsibility|Leakage on SCM|Unknown cause
ZF|100020562|25/05/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly test|function|scm|scm|assy|operator error|sensor will not read with new ETU|Operator Mistake
Q1|7101172|22/04/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM 14 H-1H DHPT failure(gauge-prob.)|unknown info root_cause
Q3|7104020|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|product defects for dept.|scm|defect locations onshore|workshop other|problem causes defect causes|production|Share-pin function activated|unknown info root_cause
ZF|100056443|26/11/2009|priority 1 |Q3|STATOIL|NORTH SEA|ATCO ORAS NOTE NOCO NOPT|test|function|scm|scm|test|unknown info cause_desc|Internal communication between PSD A & B|unknown info root_cause
ZF|P6000029772|03/12/2013|priority 2 |Q3|ENGIE|NORTH SEA|NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|other causes damage|damage from wear and tear|Debris in Strainer|Contamination  similar QN 200286860
ZF|P6000067533|27/12/2010|priority 2 |Q3|KIRINSKOYE SPS|unknown info region|NOCO ATCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
Q3|7103553|06/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations onshore|fks adm.|initial direct product problem|leakage|LP hydraulic leak of 600 litres/day|Control valve leaking
ZF|100037966|06/02/2008|priority 3 |Q3|BP|unknown info region|NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|Change: batch cert. to batch management
ZF|P7000039672|22/03/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage during transport|scm hyd mech components|baseplate|assy|operator error|Base Plate Danificada|unknown info root_cause
Q3|100009059|14/02/2001|priority unknown info priority|Q3|EXXONMOBIL|GOM|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|workshop other|root cause other|logisticspacking shipping damage|M&M SCM transport-damage in US|SCM damaged during transportation in US
ZF|P6000108025|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100049000|06/02/2009|priority 3 |Q1|BP|GOM|NOPT NOTE NOCO|damage|unknown info damage_desc|scm|scm|vendor|material error|SEM A failed to restart.|Defective RAM-chip  reduced lifetime
ZB|P7000000897|unknown info defect_date|priority 3 |Q1|SHELL|unknown info region|OSNO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|BC10 - SCM Locking Mechanism Not Working|unknown info root_cause
ZF|P6000100953|25/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|Discolored outercan marking|Faded paint lines on outercan
ZB|7104075|27/03/2008|priority 2 |Q1|SHELL|GOM|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hydraulic|other scm hydraulic|vendor|equipment malfunction|SCM 8 HP-LP Leak  Macaroni A4|SCM 8 HP-LP Leak  Macaroni A4
Q3|3794920|16/03/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|product defects for dept.|scm|defect locations onshore|montasje|initial direct product problem|function|Downhole monitoring P/T after SCM modifi|unknown info root_cause
ZF|100016901|02/02/2004|priority unknown info priority|Q3|BP|GOM|NOTE NOCO NOPT|service maintenance|unknown info damage_desc|scm electrical|pressure transducers|operation maintenance|expected wear and tear|PT failure|Unknown error. It may be a PT error.
ZF|P7000024900|25/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm sem el opt component|sem mech. components|intercompany|kongsberg|SCM BC 10 39 - lack of el can orin|unknown info root_cause
ZF|P7000020444|17/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm hyd mech components|outer can|other causes damage|cause not found|Pino guia não monta - MARLIM SN 03|Sem evidência da causa
ZF|P7000039672|05/11/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|interface issue|scm el opt components|el. connector|assy|damaged during assembly|Base Connector Damaged|unknown info root_cause
ZF|P7000001621|02/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm|scm|test|tooling|Hércules  Lab Test box Max. Voltage|SCM MMR
ZF|100056261|10/01/2008|priority 3 |Q3|MURPHY|WEST AFRICA|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|change batch sertificat to batch managem
ZF|100033987|26/08/2004|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|vendor|unknown info damage_desc|subsea sensors (not in scm)|other subsea sensors|operation maintenance|expected wear and tear|Unstable readings from analog DHI gauge|Simulator instability  long term use.
ZF|100038200|04/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|Anadarko RIT Procedure Update|RIT procedure needs to be revised
ZF|P7000008275|22/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|wrong test procedure used|scm|scm|other external causes|customer error responsibility|Troca de fluido SCM Tambau SN 11|unknown info root_cause
ZF|P6000064911|20/04/2015|priority 2 |Q3|TOTAL|NORTH SEA|NOCO NOTE ATCO|test|function|scm el opt components|opt. connector|vendor|specification not followed|OC in outercan|Outer Can not produced within SPC
ZF|P6000039844|19/10/2010|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO|documentation|procedure process error|scm|scm|projects|documentation error|Material not delivered to plant|unknown info root_cause
Q3|7104075|28/02/2001|priority unknown info priority|Q3|SHELL|GOM|NOCO NOPT ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CVLP-23 will not close|unknown info root_cause
ZF|100035013|12/10/2006|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|do not use|scm|scm|assy|operator error|Workshop error  Documentation|unknown info root_cause
ZF|100035400|27/05/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|unknown info damage_desc|scm|scm|assy|missing operation|SCM 55/llog 1 broken EC connector|Broken plastic boot on EC7
ZF|100027228|18/09/2003|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|service maintenance|offlimit pressure|scm hydraulic|other scm hydraulic|assembly test|operator error|HP return line overpressurised|HP return line overpressurised
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|electrical|pressure transducer|defect locations onshore|montasje|initial direct product problem|material|GFS SCM 07  Bytting av trykktrandsusere.|unknown info root_cause
ZF|P6000083428|06/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100020278|01/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|wrong part assembled|scm|scm|vendor|assembly error|Pin not fit|Change pin to smaller one which fits
ZF|P7000001843|02/02/2017|priority 3 |Q3|PETROBRAS|unknown info region|NOTE NOPT NOCO ATCO|damage|damage during assembly|scm el opt components|el. connector|test|incorrect set up testing|MMR - EC6  EC7 and EC8 Damaged|Absence of Guide Bush on SCMTS
ZB|P6000080678|02/12/2014|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|scm|scm|service :|improper job preparation|SCM inability to read MLCS PTTT|SCM inability to read MLCS PTTT
ZF|P6000069056|20/02/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|damage|damage due to handling|scm hyd mech components|hydraulic tubing|other causes damage|qn cancelled|Damage on pipe to accumulator.|Damage on tubing to accumulator.
ZF|100056443|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|other defect|functional|fks quality system issues|management responsibility|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZB|P6000055605|14/09/2011|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|procedure error|scm|scm|engineering|engineering error|Correct to RAL 1004 in PRD-0000024062|Procedure corrected to RAL 1004
ZF|P7000039672|28/12/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|ANOMALIA NA COLORAÇÃO.|unknown info root_cause
Q3|100009059|13/03/2001|priority 1 |Q3|EXXONMOBIL|GOM|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations onshore|tank test|initial direct product problem|leakage|Observed water in silicone after H.test|unknown info root_cause
ZF|P6000077638|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000024900|07/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|physical damage|scm hyd mech components|control valve|other causes damage|cause not found|DCV without the centralizer of th O'ring|unknown info root_cause
Q1|7100320|05/03/2002|priority 3 |Q1|PETROBRAS|unknown info region|NOPT NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|defect locations offshore field|campos basin|initial direct product problem|damages|PLFD-150 card malfunction|PTC-element on PLFD card damaged
ZF|P6000105542|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|GFS SCM 05  Bytting av PT'er.|unknown info root_cause
ZF|P6000104111|16/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|vendor|equipment malfunction|High flow restriction through HC53|Loose metal part found in HP supp.header
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|unknown info region|NOTE NOPT NOCO ATCO|assembly test|function|scm hydraulic|other scm hydraulic|engineering|procedure error|Too high cracing pressure on check valve|Cracing pressure not verified on SCM
Q3|7105129|05/06/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM I 01|unknown info root_cause
Q1|7102643|02/10/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 10 ÅsgA Y2-H PT Func.MV1 open malf.|unknown info root_cause
ZD|P6000132097|05/08/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|marking|marking content error|object types to eng matl class|scm|vendor|clarification|cert issue(serialisation)|unknown info root_cause
ZF|100036936|03/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|damage from corrosion|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|unknown info root_cause
ZF|100035013|04/03/2009|priority 3 |Q3|SHELL|unknown info region|NOCO NOPT NOTE|other defect|unknown info damage_desc|fks quality system issues|noncompliance to industrial standard|other external causes|unknown info cause_desc|SCM 13 not comunication with SPCTU|See QN no 200120994
ZF|P6000083428|01/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|project|project requested unfinished shipment|scm|scm|intercompany|kongsberg|Leaking Valve on SCM|unknown info root_cause
ZF|P6000100953|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|machining|thread error|scm hyd mech components|outer can|engineering|engineering error|To short threads in outercan|Interface with EC adapter not verified
ZF|7102643|22/03/2010|priority 4 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|other defect|physical|scm|scm|qa qs qi|final inspection error|F&D 16 Socket left on SCM|Socket left on SCM
ZF|P6000064909|11/02/2014|priority 1 |Q3|TOTAL|NORTH SEA|NOCO ATCO NOTE|test|component error|scm|scm|test|damaged during testing|SCM#5 unusual value for PT16|Unstable PT readings  S1 300408311
ZB|100035118|23/05/2016|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|cleanliness|scm|scm|test|damaged during testing|Vincent WOCM DCV Leak Test|Contamination during test
ZB|100049000|22/05/2009|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|change deviation request|part substitution request|scm|scm|vendor|material error|DHFC SCM 05 RAM Warning|Defective RAM chip
ZF|100035014|09/05/2005|priority 1 |Q3|SHELL|unknown info region|NOPT NOTE NOCO ATCO|assembly test|interface of components issue|scm|scm|vendor|fabrication error|SCM not able to install or pull off|Chatter marks might be root cause.
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|marking|marking content error|scm|scm|materials stores|operator error|MIssing batch numbers|unknown info root_cause
ZF|P7000039672|26/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|missed operation|scm|scm|test|operator error|Não Atendimento do Critério Hiperbárico|unknown info root_cause
ZF|P6000108469|27/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|specification error|computer system software|network config|engineering|engineering error|Wrong routing file on N: Drive|unknown info root_cause
ZF|P7000008275|31/03/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|scm|scm|test|missed operation|SCM TBU 03|unknown info root_cause
ZF|100037967|09/11/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|marking|marking content error|scm|scm|engineering|dwg error|MCM Lock/Unlock marking difficult to see|MCM Funnel orientation on Manifold
ZF|7103233|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|unknown info damage_desc|scm|scm|assy|unknown info cause_desc|unknown info notification_desc|unknown info root_cause
Q3|7101172|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI ATCO|scm rcm|scm|defect locations offshore field|deepsea trym|initial direct product problem|function|SCM sand detector sensors no readings|SIO card had not been upgraded at Kitron
ZF|P6000068912|12/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|7103382|07/06/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|SCM  Problem filling nitrogen on SCM.|Procedure updated with Pn for tool.
ZF|P6000104111|10/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|damage during assembly|scm hyd mech components|other mechanical components|assy|operator error|Damage parts|Damaged during dissassembly
ZE|P6000068912|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Markup SCM/SRM HFT/PSM  Luanda Workshop|Documents updated
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
Q3|3794920|24/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations offshore field|statfjord c|initial direct product problem|function|Readings unstable from ext. sensors|DHI card fault
ZB|100048038|27/09/2007|priority 2 |Q1|AGBAMI|unknown info region|NOTE NOCO|assembly test|function|scm electrical|modem pcbs|vendor|component error|No communicate with SEM B (address 530)|Defective Tantal Capacitor C25
ZF|100016711|11/11/2003|priority 3 |Q3|BP|GOM|NOTE NOCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|hydraulic manifolds|engineering|design specification drawing error|Lee Plug has loosened|Engineering failure
ZF|100026567|24/06/2004|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly test|miscellaneous|fks quality system issues|fks quality system issue|engineering|material master dbi error|Use of wrong technical document|Document not linked correctlyOperator did not see version indicator
ZF|100017278|08/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|dbi error|scm hyd mech components|outer can|engineering|dbi error|Wrong PN in BOM for SCM PN 100017278|Wrong parts in stock  due to DBI error
ZF|P6000102687|09/03/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|damage during assembly|scm|scm|assy|improper handling|WOCM installed with plastic protection|Protection caps not removed
ZF|100046387|05/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|missed operation|scm|scm|test|tooling|CITV and MPFM test in FAT|Lack of functional CPI test equipment
ZF|100001156|24/05/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|damage|damage during testing|electronic boards|other eletronic boards|assy|operator error|Too high voltage supplied to SCM|Too high voltage supplied to SCM
ZB|100056261|01/02/2010|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm electrical|other scm electrical|test|damaged during testing|SCM Alarms and loss of Comms to SCMs|SCM Alarms and loss of Comms to SCMs
ZF|100037965|22/03/2008|priority 1 |Q3|BP|unknown info region|ATCO NOTE NOCO NOPT|damage|wear & tear|scm|scm|other causes damage|cause not found|FPSO NCR 27 - Com. Issues on SEM A/B|unknown info root_cause
ZF|P6000063531|07/03/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm|scm|test|incorrect set up testing|Availability of NAXYS/ALD simulator|unknown info root_cause
ZF|100001156|08/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|test omitted|scm|scm|test|incorrect set up testing|Reduction of mobilization scope|unknown info root_cause
ZF|P6000042308|11/06/2009|priority 4 |Q3|TULLOW|WEST AFRICA|ATCO NOCO NOTE|test|function|scm|scm|other causes damage|no noncompliance|Framo MPFM incompatibilities|Framo MPFM incompatibilities
ZF|P6000104112|27/09/2018|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|test omitted|object types to eng matl class|scm|test|tool out of calibration|Concession to deviate from procedure|unknown info root_cause
ZD|P6000055605|11/04/2013|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|other defect|functional|scm sem el opt component|sem cable & wiring|manufacturing engineering|me programming|PROBLEM WITH COMM. - SCM315 SEM B.|Problem With Comm. SEM B.
ZF|P6000101955|06/07/2014|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|other causes damage|qn cancelled|2- Drained sil. fluid in SCM S/N 2 and 3|unknown info root_cause
ZB|P6000088604|29/07/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|specification error|scm|scm|intercompany|singapore|Chevron  SCM  Warranty Claim|unknown info root_cause
ZF|P7000001621|04/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage during assembly|scm|scm|assy|damaged during assembly|PT de LP danificado durante montagem|PT danificado ( reparo hercules)
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM S/N 11 G-2H GFA PT MV2-Open(manif.)|PT
ZF|100048038|31/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|ATCO NOTE NOCO NOPT|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 28|Damage in warehouse handling
ZF|100048038|08/11/2006|priority 3 |Q3|AGBAMI|unknown info region|NOPT NOCO NOTE ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|operator error|Nitrogen leakage internal|fitting not tightened enough
Q3|3812476|12/04/2002|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Forurensning fra XT under HFT|unknown info root_cause
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|electrical|pressure transducer|defect locations onshore|montasje|initial direct product problem|material|Change of pressure transducers|unknown info root_cause
Q3|7100320|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOPT NOTI NOCO ATCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Hercules SCM 18|Aluminium washers in solenoids
ZF|7104075|21/06/2005|priority 3 |Q3|MARUBENI|GOM|NOCO NOPT NOTE ATCO|assembly test|function|scm|scm|vendor|component error|SCM INTERNAL  PT  FAILURE|Internal PT failure
ZF|100052701|03/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|test|function|scm|scm|vendor|unknown info cause_desc|Operation problems during FAT|Error to be confirmed in QN200124450
ZF|P6000079984|10/04/2012|priority 3 |Q3|EXXONMOBIL|NORTH ATLANTIC|NOTE NOPT ATCO NOCO|test|function|electronic boards|other eletronic boards|test|incorrect set up testing|Problems with DHI 205|DHI not configured for specific project
ZF|P7000000897|02/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm|scm|engineering|engineering error|SCM - SEM LEITURA|PN P7000031845  - PO 47353105
ZF|100036936|26/02/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTE|test|function|scm|scm|test|unknown info cause_desc|No final inspection performed on SCM|unknown info root_cause
ZE|100035118|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Enfield - SCM Issue|SCM Issue
ZE|P7000001621|18/04/2018|priority 4 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm_components|assembly|lack of awareness|MMR - Compensator Bladder Leakage|Inspeção visual não identificou rebarba
ZE|P7000039672|30/08/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|instrumentation|scm pressure transmitter|test|component malfunction|Anomalia na leitura do PT55 pela SEM A|Anomalia na leitura do PT55 pela SEM A
ZF|P6000105542|29/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|scm|scm|vendor|equipment malfunction|Flow restriction in SCM HP supply header|Error during manuf. of M.B
ZF|P6000098616|11/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|missed operation|scm|scm|assy|operator error|Silicone drainport loose.|Drain port not torqued  see RCA.
Q3|3812476|08/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations offshore field|norne fpso|initial direct product problem|function|SCM press. transm. faults well C4-H|DC/DC converter in AI-150 card
ZF|100048038|03/05/2006|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|change deviation request|part substitution request|fks quality system issues|quality management system|engineering|dwg error|Change of IWC Compensation|unknown info root_cause
Q3|7101172|20/12/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|electrical|modems communications|defect locations offshore field|deepsea trym|initial direct product problem|function|Communication errors with SCM (Subsea)|PLMS card defective/card replaced
ZF|100050383|15/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|assembly test|function|scm|scm|engineering|engineering error|Diode missing between SEM A and SEM B|Missing diode-coupling in DO-outputs
ZF|P6000088751|19/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|functional|electronic boards|comm.link (power line)|engineering|engineering error|QAM to FSK - Make 150 Startup permanent|unknown info root_cause
ZD|P6000028371|25/02/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|coating plating|incorrect colour coating|scm hyd mech components|outer can|vendor|specification not followed|Coating specifications|unknown info root_cause
ZF|100031223|09/02/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|drawing error|scm|scm|other causes damage|no noncompliance|Missing GA Drawing for SCM PN 100031223|DWG linked to P/N
ZB|P6000063531|19/06/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|missed operation|object types to eng matl class|scm|other causes damage|planning error|DHG Configuration (Emerson|unknown info root_cause
ZF|100030542|26/04/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|wrong part assembled|scm|scm|purchasing|unqualified vendor used|SCM bladder issue|unknown info root_cause
ZB|100052850|19/08/2009|priority 2 |Q1|REPSOL|unknown info region|NOTE NOCO ATCO NOPT|other defect|unknown info damage_desc|customer compliant|noncompliance to customer requirement|other external causes|customer error responsibility|REV Com: Lack of comm. with SEM A in SCM|unknown info root_cause
ZF|P7000024900|04/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|interface issue|scm hyd mech components|other hydraulic components|vendor|final inspection error|DAMAGE ON THE THREAD|115215 - TESS DRAMMEN AS  AVD. KONGSBERG
ZF|P6000105542|21/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|physical damage|scm hyd mech components|check valve|vendor|equipment malfunction|Bad thread check valve|Bad threads on check valve
ZE|100017997|02/09/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|customer compliant|unsatisfactory customer satisfaction|causes for improvement|process procedure ineffective|SCM EC port corrosion|unknown info root_cause
ZF|P6000093498|07/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm|scm|engineering|engineering error|Cant mount the valves isnt space enough|Lack of interface check prior to release
ZF|P6000043122|19/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOPT NOCO NOTE|documentation|procedure process error|scm|scm|projects|documentation error|Material not delivered to plant|unknown info root_cause
ZF|100048038|21/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|ATCO NOCO NOPT NOTE|change deviation request|process substitution request|fks quality system issues|product realization|other external causes|customer error responsibility|Customer request change in Flow Restrico|Customer Requested Change
Q3|7102969|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|documentation|Feil i prosedyre om change over valve.|unknown info root_cause
ZE|P1000018406|08/11/2010|priority 3 |Q3|BP|GOM|OSTS NOCO DLFL NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|qa qs qi|documentation error|Escape: Assembly/ QC- Wrong N/A FAT proc|Traiing
Q3|7105129|10/04/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|mechanical|outer can|defect locations onshore|fat|initial direct product problem|dimension|SCM I 01|Wrong thickness on anodes
ZF|P7000024900|02/12/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|part lost|scm hyd mech components|hydraulic coupler|vendor|missing parts|FALTA DE ORING NO COUPLER|1242 - HTS maskinteknikk as
ZF|100066325|15/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|damage|damage from corrosion|scm hyd mech components|other mechanical components|vendor|packaging handling|SCM interface showing signs of corrosion|SCM interface showing signs of corrosion
ZF|P6000116166|19/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|cleanliness|scm hyd mech components|compensator|vendor|specification not followed|Dirty retur compensator|Outside cleanliness requirement
ZF|100035014|23/10/2012|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|functional|fks quality system issues|quality management system|qa qs qi|final inspection error|Failed to call in customer to witness FA|Customer witness not informed
ZF|P6000068924|14/12/2011|priority 3 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE NOPT|raw material|incorrect material|electronic boards|other eletronic boards|test|damaged during testing|Problem with CWDM|Replaced according to QN200238941
ZD|P6000084242|21/12/2011|priority 1 |Q2|CONOCOPHILLIPS|unknown info region|ATCO NOCO NOPT NOTE|marking|marking content error|scm|scm|intercompany|kongsberg|(SS) Error on SCM Name Plate|Marking error on name plate
ZF|7100320|05/09/2003|priority 3 |Q3|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|service maintenance|unknown info damage_desc|scm electrical|i o pcbs|vendor|component error|SCM 19 Herc. SEMA AI/SEMB DC/DC failure|AD converter with known weakness.
Q3|7101172|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|function|kommunikasjonsfeil på rack.|unknown info root_cause
ZF|100026567|31/10/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly test|marking|scm mech w mb|outer can|engineering|design specification drawing error|Difference on drawings regarding marking|Missing marking on assy dwg
ZF|100037428|20/02/2006|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOTE NOPT NOCO|assembly test|function|scm|scm|other external causes|customer error responsibility|SCM production error - ROSA P3 XT|Damaged during field-testing.
ZF|P6000069820|10/01/2012|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOCO NOTE|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Version update
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|GFA Bundle(Haliburton) IR very low|unknown info root_cause
ZB|100018600|30/04/2004|priority 3 |Q1|PETROBRAS|unknown info region|NOCO NOPT ATCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|outer can|assembly test|assembly test error|Water found in dielectric fluid|Leak in vacuum port plug.
ZF|P6000055605|24/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly|assembled incorrectly|scm hyd mech components|check valve|assy|operator error|filling port check valve missing|Filling port not assembled in mech assy.
ZF|P6000065886|15/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|design|drawing error|scm hyd mech components|accumulator|engineering|dwg error|Akkumulator assy må rettes opp|Design error on DWG
ZB|P6000091085|06/05/2015|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|electronic boards|other eletronic boards|vendor|equipment malfunction|Shell OWIRS Claim 002 SNTBD (PSD)|Component error
ZF|P6000068912|21/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm sem el opt component|other scm sem el opt components|other causes damage|no noncompliance|Additional  testing SEM|No SCM failure detected in extend. test
Q3|3801623|03/01/2001|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|inhouse fat|initial direct product problem|cleanliness|Collet Connector needs refurbishment|unknown info root_cause
ZF|100054943|18/09/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|marking|marking content error|scm|scm|assy|operator error|Incorrect SEM adresses|Missed single address in series
ZB|7102969|05/04/2007|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly test|interface of components issue|subsea sensors (not in scm)|pressure transmitter (pt)|engineering|lack of training|SCM unable to access and send +30VDC|Electronic component interface issue
ZF|100037427|26/12/2006|priority 1 |Q3|TOTAL|WEST AFRICA|NOPT NOTE ATCO NOCO|assembly test|function|scm|sem|other causes|qn cancelled|no communication on SEM B|Activity transferred to SN300117777
ZF|P6000123495|09/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|ss compl. & w.over xt general|tree assembly|vendor|specification not followed|CV to be changed out on SCM|unknown info root_cause
Q3|3812476|06/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|norne fpso|initial direct product problem|function|SCM  DHI card on SEM A not functioning|Not known
ZB|P6000065886|24/04/2012|priority 1 |Q1|ENI|NORTH SEA|ATCO NOTE NOCO|test|function|scm|scm|vendor|equipment malfunction|Problem with communication|Faulty board
ZF|P6000063632|23/12/2010|priority 1 |Q3|AQUILA PHASE 2|unknown info region|NOTE NOCO ATCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZE|P6000104112|18/09/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|marking|marking content error|scm|scm|causes for improvement|documentation|Name plate has wrong max VAC|Engineering error  marking on name plate
ZF|P6000126219|15/11/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|object types to eng matl class|scm|other causes damage|cause not found|PT's increased after storage of SCM|High values on PT
ZF|P6000042969|25/11/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|other defect|part lost|scmmb|other hydraulic components|intercompany|kongsberg|Feil plukk av hydralic  plug hex hea|Picking fault in warehouse
ZF|100018531|07/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|coating plating|coating defect|scm|scm|paintshop|operator error|Mecanismo de travamento|Erro no isolamento da Extension Rod
ZF|P6000079984|22/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. testNo SCM failure detected in extend. test
ZF|P6000069056|30/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm|scm|vendor|material error|Voltage is beyond the criteria|voltage drop due bad Faston cable-conn.
ZF|P6000042969|24/06/2011|priority 1 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|other causes damage|cause not found|LP1 and LP2 is leaking oil|unknown info root_cause
ZF|100048038|18/12/2006|priority 3 |Q3|CHEVRON|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|operator error|Water inside SCM after hyperbaric test|PT hose not tighten enough
Q3|7104670|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM Sn.01|unknown info root_cause
Q3|7102643|28/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|electrical|sem powersupply|defect locations offshore field|åsgard a|initial direct product problem|function|Low IR values on SCM SEMB  well J-3H|PLFS160 card damaged
ZF|100050519|29/11/2007|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly test|do not use|scm|scm|assy|operator error|SCM accumulator|unknown info root_cause
ZC|100020562|06/10/2005|priority 2 |Q2|BP|GOM|NOTE NOCO ATCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other causes|no noncompliance|SCM Bladder burst (QTY5)|"2 root causes  see text in ""follow up"""
ZF|100025661|20/03/2006|priority 3 |Q3|SHELL|GOM|NOPT ATCO NOTE NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|component error|Damaged Bladder|Bladder Failure
ZD|7104075|11/11/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|machining|surface finish error|scm hyd mech components|outer can|vendor|specification not followed|ECs failed roughness inspection|unknown info root_cause
ZF|100037428|30/12/2007|priority 1 |Q3|TOTAL|WEST AFRICA|ATCO NOPT NOCO NOTE|assembly test|function|scm|sem|engineering|engineering error|No communication with DHG|faulty CPU card
ZF|100037428|10/05/2007|priority 2 |Q3|TOTAL|WEST AFRICA|NOPT NOTE NOCO|damage|wear & tear|sensors|scm pressure transmitter (pt)|vendor audit|unknown info cause_desc|Failed PT53 on SCM #9|unknown info root_cause
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|scm|scm|other causes damage|cause not found|08-MEGI-017: RAM Warning Error|Error Message
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE|other defect|unknown info damage_desc|fks quality system issues|quality management system|other causes damage|unknown info cause_desc|Rosa 401 invalid pressure sensor reading|unknown info root_cause
Q3|7100320|03/11/1999|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOPT NOTI ATCO|product defects for dept.|scm|defect locations offshore field|campos basin|initial direct product problem|function|Failure on SCM sn. 4 adress 4B|Failure of AIDO board in SCMFailure of AIDO board in SCMFailure of AIDO board in SCM
ZF|7102969|26/05/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|material master error|scm|scm|engineering|engineering error|Wrong nipple PN on MEGI Phase II SCM BOM|BOM Error
ZF|P6000083428|15/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|material master error|scm hyd mech components|outer can|engineering|specification error|Wrong o-rings|Wrong O-rings in Outercan BOM
ZF|P7000024191|12/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Leakage out of acceptance criteria|1659 - Oceaneering Rotator - SN 72173
ZF|100037428|11/04/2011|priority 1 |Q3|TOTAL|WEST AFRICA|NOPT NOTE NOCO|other defect|functional|electronic boards|dhi|intercompany|kongsberg|Down Hole Gauge testing failure with SCM|DHG cards
Q3|7102643|06/12/1999|priority 3 |Q3|STATOIL|NORTH SEA|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|Åsg SCM 24  AWV PT not working well I2-H|Not known
ZF|100035400|28/11/2007|priority 1 |Q3|WALTER|GOM|NOPT NOCO NOTE ATCO|change deviation request|conversion approval|scm|scm|other causes|no noncompliance|New Pod Software to be downloaded.|New Pod Software to be downloaded.
ZF|P7000000897|19/06/2012|priority 1 |Q3|SHELL|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm el opt components|trafo unit|intercompany|kongsberg|SEM B communication failure|unknown info root_cause
ZF|P6000076121|15/11/2011|priority 3 |Q3|CNOOC|unknown info region|NOTE NOCO ATCO|test|cleanliness|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Chips found inside the HP-Config Plug|Plugs not cleaned by supplier.
ZF|100031193|05/01/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|FAIL WITH CHECK VALVES|unknown info root_cause
ZF|100037229|15/08/2005|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE NOPT|assembly test|function|scm|scm|other causes|no noncompliance|SCM stuck in EHXT|No failure found on parts
ZF|P6000028371|25/02/2008|priority 3 |Q3|SHELL|GOM|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|Change: batch cert. to batch management
Q3|7102643|17/02/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations onshore|workshop|initial direct product problem|documentation|SCMs  7L of silicone oil drained out|Important notice attached to wrong SCM
Q3|7102643|04/01/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM  communication failure SEM B (Y1-H)|Not known
ZF|P7000024900|08/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|damage during transport|Arranhão na adapter plate CVLP|unknown info root_cause
ZD|P6000066700|24/11/2010|priority 1 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|documentation|incorrect certificates records|scm|scm|vendor|operator error|CERT ISSUE/WRONG PART|VL-INCORRECT CERTS
ZF|P6000064909|20/03/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|Change of Hydraulic Fluid in LT prod 10|Hydraulic Fluid change in procedure.
ZF|100068622|28/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|specification error|scm|scm|other causes damage|cause not found|SCM not according to Bills of Material.|Part obsolesce  replaced with new P/N
ZF|P6000068912|28/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|component error|scm|scm|vendor|specification not followed|Silicon pressure will not follow|Grease inside the gauge port (baseplate)
ZF|P6000068902|20/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring error|Human error  process not maintained
ZF|P7000000897|17/10/2011|priority 1 |Q3|SHELL|unknown info region|NOCO NOTE ATCO NOPT|test|function|test and transportation|other scm test & transport equipment|other external causes|customer error responsibility|Downhole failure of DHI 113.|unknown info root_cause
ZF|7103382|10/03/2004|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|other defect|physical|scm|scm|other external causes|unknown info cause_desc|BOURI SCSSV hyd leak /stuck possition|See attached Report
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|scm|scm|other causes damage|cause not found|08-MEGI-016: RAM Warning Error|Error Message
ZF|100056261|22/02/2011|priority 2 |Q3|MURPHY|WEST AFRICA|NOCO ATCO NOTE NOPT|documentation|missing certificates records|scm|scm|engineering|engineering error|Missing Engineer Sign offs|Section not N/A'd
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Bytte av Pressure transmittere.|unknown info root_cause
ZF|100037426|02/05/2005|priority 3 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT|coating|do not use|scm|scm|other causes|no noncompliance|Corrosion on serrated lock washers|unknown info root_cause
ZF|100027228|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|other scm mechanical|engineering|dwg error|Silicon Leakage on SCM  SN 5 6134 SVAN|Root cause unknown.
ZF|100050383|09/05/2007|priority 4 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|assembly test|cleanliness|scm|hydraulic valves|engineering|engineering error|Replace control valves on TORDIS|unknown info root_cause
Q3|7101172|18/09/2000|priority 2 |Q3|STATOIL|NORTH SEA|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|leakage|Leak under SCM when operating SIV (D-3H)|Not known
ZF|P7000024900|30/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|component error|scm hyd mech components|check valve|vendor|equipment malfunction|Check valve out of acceptance criteria|1242 - HTS Maskinteknikk AS
ZE|P6000121268|27/03/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|physical damage|scm el opt components|el. connector|test|damaged during testing|(CDM)SCM EC6 Damage - ENI Jangkrik|Electrical connector damage
ZF|P6000088604|08/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000043766|19/06/2009|priority 2 |Q1|PETROBRAS|unknown info region|NOPT NOCO NOTE ATCO|test|function|scm|scm|vendor|equipment malfunction|Communication to Pig Detector|Communication To Pig Detector
ZE|100051992|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Vincent - SC  Issue|SCM Issue
ZB|100068622|02/03/2017|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|documentation requirement|incorrect user documentation (customer)|scm|scm|other external causes|customer error responsibility|No contact w/gauges SCM PN100068622 SN10|RFQ incomplete
ZF|3787102|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm hyd mech components|control valve|assy|operator error|Lekkasje mellom solenoide og pilot|Screw not tightened / not correct screws
ZF|P6000101955|03/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|specification error|computer system software|network config|engineering|engineering error|Wrong subnet adress on subsea routers|unknown info root_cause
ZF|P6000105542|07/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|interface issue|scm hyd mech components|outer can|vendor|specification not followed|EC adapter don`t fit.|Hole pattern outside of specification
ZF|P6000064909|25/05/2011|priority 3 |Q3|TOTAL|NORTH SEA|NOCO NOPT NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|machine shop personnel|operator error|Wiring error and cut on hose from EC5|Follow up in ZF QN:200209938
ZF|P7000039672|08/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|design|dbi error|hydraulic distribution|other hydraulic components|engineering|ecn change|ECN  6147855 - PN  P7000039672|ECN
ZF|P6000102554|08/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|procurement|incomplete kit of parts|electric optical jumpers|other electric optical products|fabrication shop personnel|improper handling|MISSING BOLTS ON EC ASSY|Bolts lost in FMC wearehouse/workshop
ZF|P6000028371|31/07/2009|priority 1 |Q3|SHELL|GOM|NOTE NOPT ATCO NOCO|marking|marking location error|scm|scm|vendor|operator error|Lock/Unlock indicator line on SCM|unknown info root_cause
Q3|3812476|08/02/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations offshore field|norne fpso|initial direct product problem|function|SCM  DH press/temp. sensor malfunction|Not known  Service Notification?
ZF|P7000000897|06/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm|scm|other causes damage|cause not found|PERDA DE COMUNICAÇÃO COM  A SEM A|Sem evidência da causa
ZF|P7000000897|09/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|hydraulic products|coupler|vendor|equipment malfunction|Coupler vazando|HTS MASKINTEKNIKK AS
ZF|P6000108984|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100035118|14/03/2005|priority 2 |Q3|PETRONAS|unknown info region|NOPT NOTE ATCO NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|hydraulic valves|other external causes|customer error responsibility|Leakage in SCM.|Contaminated hydraulic fluid
Q1|7102643|unknown info defect_date|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|electrical|pressure transducer|defect locations onshore|workshop|initial direct product problem|function|PT for SIV not working  Ågotnes|PT failure  PT replaced
ZF|P6000060453|29/03/2010|priority 3 |Q3|HEIDRUN NORTH|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (gas)|scm|scm|assy|operator error|Nitrogen leakage inside SCM|Nitrogen leakage due to loose fitting
ZF|P6000058949|08/02/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|specification error|scm|scm|engineering|dwg error|Wrong tubing in BOM|Design error  wrong material specified
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|ECN 7058839 - P7000017839
ZB|100048038|17/08/2008|priority 3 |Q1|CHEVRON|unknown info region|NOPT NOTE NOCO|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|SCSSV 1 PT reading improperly|unknown info root_cause
ZF|P6000069056|06/03/2012|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|test|function|scm|scm|other causes damage|cause not found|Recalibration of  cards|Most likely irregularities in test setup
ZF|100001156|08/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ORAS ATCO NOCO|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|100037428|16/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Extertnal 4-20ma sensors not working|FMC opr mistake during SCM wiring
ZF|P6000064911|14/12/2011|priority 3 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO NOPT|raw material|incorrect material|electronic boards|other eletronic boards|test|damaged during testing|Problems with CWDM|Follow-up in QN200238941&200238942
ZF|P6000104114|19/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|Faulty wiring on secondary side of TA1|SCM wiring fault (opr error)
ZB|P6000088751|30/08/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|documentation requirement|other specify in comments|fks quality system issues|quality management system|intercompany|kongsberg|FMC Quality Rep not witnessing SCM FAT|Misaligned H and W presence duration
ZB|P6000088751|10/04/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|physical|object types to eng matl class|scm|documentation requirement|other specify in comments|GWF-2/Transportation Issue|No Procedure in place
ZF|P6000110991|07/11/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|object types to eng matl class|scm|test|missed operation|Unable to perform test according to HFT|CPI SPCTU and config not available.
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZB|P6000043122|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE NOCO|test|function|electronic boards|main boards cpu & i o|other causes damage|qn cancelled|Punch List SCM SSS 03|New SW downloaded  QN cancelled
ZF|100048038|04/01/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|ATCO NOTE NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|operator error|Leak from IWC return|failure to put Loctite on threads
ZF|P6000079032|24/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|assy|operator error|PSD A card  doesn't  boot|Opr.failure caused SCM wiring error
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|NOCO NOTE ATCO NOPT|assembly test|function|scm|scm|vendor|component error|BURNT RESISTOR ON AICF BOARD|BURNED RESISTOR ON AICF BOARD
ZF|P7000016420|05/12/2011|priority 1 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm hyd mech components|locking mechanism|qa qs qi|final inspection error|Revestimento não conforme.|Revestimento
ZB|100020562|20/02/2009|priority 1 |Q1|BP|GOM|NOPT ATCO NOCO NOTE|test|function|scm electrical|other scm electrical|other causes damage|no noncompliance|SEM A not responding|No Non-conformance
ZF|P7000001843|03/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|component error|scm|scm|vendor|equipment malfunction|Funcionamento de sensor - Flow meter|unknown info root_cause
ZB|100017278|29/09/2008|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|other external causes|unknown info cause_desc|Leakage in solenoide valve in SCM|unknown info root_cause
ZF|100050383|19/06/2013|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|test|tooling|Lack of external test equipment|unknown info root_cause
ZF|100049000|26/04/2010|priority 1 |Q3|BP|unknown info region|NOPT NOCO NOTE ATCO|documentation|missing certificates records|scm|scm|projects|documentation error|Incomplete databook|Incomplete databook - missing signatures
Q3|100018600|24/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|The centre rod is slow to operate|unknown info root_cause
ZF|P6000042308|06/11/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|change deviation request|process substitution request|ss compl. & w.over xt general|tree assembly|other causes damage|no noncompliance|Remove SCM & send to CS|unknown info root_cause
ZB|7104075|10/03/2009|priority 1 |Q1|MARUBENI|GOM|NOPT NOTE NOCO ATCO|other defect|functional|scm electrical|power supply|vendor|equipment malfunction|Loss of Communication SEM-A|Loss of Communication SEM-A
Q3|100018600|28/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|ATCO NOCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|B electronic don't switch off MFM power|unknown info root_cause
Q2|7104020|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Change of solenoids|unknown info root_cause
ZF|7101401|01/06/2004|priority 2 |Q3|PETROBRAS|unknown info region|NOPT NOTE ATCO NOCO|assembly test|part incorrect|scm mech w mb|locking mechanisms|engineering|design specification drawing error|Marlim SCM Extencion Rod|Wrong P/N in spare part list
ZF|100018600|30/03/2005|priority 1 |Q3|PETROBRAS|unknown info region|NOPT NOCO ATCO NOTE|assembly test|function|electronic boards|other eletronic boards|engineering|dwg error|East Marimba Manifold. SCM A  SEM B.|Electrical overstress in tantalum cap.
ZF|P6000063632|04/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|machining|position error|scm hyd mech components|baseplate|engineering|dwg error|Et rettur hull for mye i baseplata|DWG error
ZF|3794920|17/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|obsolescence issue:&|not available|scm sem el opt component|other scm sem el opt components|other causes damage|shelf life expiry|PT for Statfjord SCM MKI is obsolete|Not able to purchase PN 3792826
ZF|100036936|08/01/2005|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM NSAT - SW fault|unknown info root_cause
ZE|100020562|03/08/2010|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|qa qs qi|documentation error|Escape: Databook Incorrect|Missing signatures
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte solonoider på ventiler.|unknown info root_cause
Q3|3801623|04/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|product defects for dept.|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|damages|Control module skifting Heidrun  CM 11|unknown info root_cause
ZF|P6000068924|30/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|function|scm|scm|vendor|coating defect|Not able to switch off IXT7 and 8|Coating has penetrated relay in PSDM600
ZF|100001156|08/11/2005|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|TESTING MED FEIL REV. PÅ PROSEDYRE|unknown info root_cause
Q3|7100320|02/12/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|material|Upgrade Hercules SCM 16-GAMA to 16-OMEGA|Wrong materials
ZE|P7000024191|23/11/2016|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|damage|damage due to handling|scm hyd mech components|locking mechanism|assembly|improperly protected|MMR - Pin of Extension Rod Smashed|unknown info root_cause
ZF|P6000079433|22/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOPT NOTE ATCO NOCO|design|dbi error|scm hyd mech components|other mechanical components|engineering|specification error|Wrong Bill Of Material and wrong parts|Coupler Interface on m.block (spc error)
ZB|100041493|04/09/2009|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE|other defect|physical|ss intervention running tool|scm running tool|other causes damage|planning error|F&D SCM for URT sent in wrong position|Procedure not followed
ZF|P6000064910|02/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|drawing error|scm|scm|engineering|dwg error|Feil i tegning for P6000065013 Mech Assy|DWG error
ZB|7103234|05/11/2014|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|scm hyd mech components|accumulator|service :|improper job preparation|NCR 313417 SCM Accumulator no pre-charge|unknown info root_cause
ZF|100049000|21/06/2011|priority 1 |Q3|BP|unknown info region|NOTE ATCO NOCO NOPT|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 27|Investigate Coupler Rotation-BPAT SCM 27
ZB|100048038|09/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|NOCO NOTE|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|SCM #1 PT51 (HP SUPPLY) SEM A FAILURE|SCM #1 PT51 (HP SUPPLY) SEM A FAILURE
ZF|100030542|26/02/2004|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly test|miscellaneous|scm hydraulic|other scm hydraulic|assembly test|operator error|Blind plug for silicon relief installed|"""Important Notice"" not read/understood"
ZB|7101401|unknown info defect_date|priority 3 |Q1|PETROBRAS|unknown info region|NOTI OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|P-35 - Vazamento de HW no Slot A|unknown info root_cause
ZF|100027228|03/08/2005|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|assembly test|do not use|scm|scm|vendor audit|unknown info cause_desc|Change of parts on locking mechanism.|unknown info root_cause
ZF|100037130|06/12/2004|priority 1 |Q3|BOURI  FEAD|unknown info region|NOCO ATCO NOTE NOPT|assembly test|handling damage|scm mech w mb|other scm mechanical|assembly test|miscellaneous|Leakage of hydraulic oil in EFAT area|SCM sprayed with Brayco in workshop
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|material|ureinheter i hydraulikksystem fra kunde|unknown info root_cause
ZF|P6000110991|20/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|dbi error|scm|scm|engineering|engineering error|Update BOM and Drawing|Old SCM rebuild to SEM 615
ZF|100051269|18/10/2013|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|assembly|assembled incorrectly|scm|scm|assy|damaged during assembly|Damage to SEM bracket and outercan tube|outercan tubing damged during lifting
ZF|P6000121268|13/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Leakage test failed|COV leaking outside acceptance criteria
ZF|P7000039672|13/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|physical damage|scm|scm|assy|damaged during assembly|Base Plate danificada|unknown info root_cause
ZF|P7000000897|05/04/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|component error|scm|scm|purchasing|purchasing error|SRT Software|delay in delivering for workshop test
ZF|P7000039672|26/06/2018|priority 4 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTE|machining|thread error|object types to eng matl class|scm|machining|incorrect tool|MMR - Broken Screw on Base Plate|Incorrect Tool
ZF|100036936|01/09/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTE|assembly|assembled incorrectly|scm|scm|test|missed operation|Scm not locked in skid.|unknown info root_cause
ZF|P7000039672|12/02/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|engineering|dbi error|Continuidade eletrica acima do critério.|unknown info root_cause
ZF|P6000039844|30/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|intercompany|kongsberg|Use of HW540 for FAT instead of HW443|Lack of Gumusut SCMTS at FMC Kongsberg
ZF|P6000064911|01/08/2017|priority 2 |Q3|TOTAL|unknown info region|NOPT ATCO NOCO NOTE|assembly|other specify in comments|scm hyd mech components|other mechanical components|engineering|continuous improvement|Strainer contact to ground|Extra isolation of strainer needed
ZF|P6000064911|06/10/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|damage|damage during testing|scm|scm|vendor|second tier supplier issue|Short-circuit in SRM4 SEM 1|Damage due to Leakage in FiberOptic pen.
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|NOCO NOTE ATCO|design|specification error|scm|scm|engineering|continuous improvement|Gluing of DHI212 board|WD design improvement.
ZE|P7000024900|04/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of training|RCA|Falta de treinamento específico
ZF|P6000077638|04/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|documentation|procedure process error|fks quality system issues|quality management system|qa qs qi|documentation error|Order started w/o ITP ready|Unclear roles/responsibility processes
ZF|P6000104116|20/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|coating plating|painting not applied|scm|scm|vendor|specification not followed|Multiple distance housings missing paint|Paint not applied acc. to dwg.
ZF|P6000068902|11/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|change deviation request|part substitution request|scm|scm|vendor|missing parts|check valve cap to be replaced|Part substitution
ZF|P7000024191|05/09/2012|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm|scm|test|incorrect set up testing|LA TEST BOX - QN|Lab test box with problem.
ZF|P6000039844|20/03/2009|priority 3 |Q3|SHELL|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|vendor|unknown info cause_desc|CPU init. fails at Poweron  OK & Reset|Error to be confirmed in QN200124450
ZF|3787102|08/12/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|other defect|physical|scm|scm|other external causes|customer error responsibility|Snorre FD 15 Welding on deck w/ WCM|Precipitate mobilization due to weather
Q1|7103233|27/02/2003|priority 3 |Q1|SUNCOR NGXT|unknown info region|ATCO NOCO NOPT NOTI|scm rcm|scm|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|SCM flowmeter reading failure on SEM B|unknown info root_cause
ZF|P6000105542|20/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|procedure error|computer system software|sem tpu config|engineering|engineering error|Config problem with CITV's|unknown info root_cause
ZB|100035013|02/06/2015|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|part substitution request|scm sem el opt component|optical penetrator (insert)|vendor|operator error|Ormen Lange Claim SCM 22|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOPT NOTI|mechanical|mechanical components|defect locations offshore field|campos basin|initial direct product problem|material|Oppgrader Marlim 01-ALFA til 01-GAMA|unknown info root_cause
ZF|3812476|04/07/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly test|interface of components issue|ss intervention running tool|scm running tool|other causes damage|planning error|Clash between the SCM and URT|Mismatch between DWG and cable tray
ZF|100049000|30/11/2010|priority 2 |Q3|BP|unknown info region|NOTE ATCO NOPT NOCO|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZB|100005667|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|other causes damage|cause not found|Warranty claim 226|Bladder leak due to FMC error
ZB|3812476|28/07/2010|priority 3 |Q1|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|other defect|physical|scm|scm|qa qs qi|final inspection error|F&D23 Loose items on top of SCM|Loose item not found during final inspec
ZF|P6000088626|19/10/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|documentation|procedure process error|scm|scm|other causes damage|no noncompliance|Bandak used wrong lift-test procedure.|No error from supplier
ZF|P6000104112|04/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|design|drawing error|scm sem el opt component|sem cable & wiring|engineering|continuous improvement|Re assemble FO on ESRS with clips|Design improved  ref ECN6158709
ZD|P7000039672|28/07/2014|priority 2 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|raw material|incorrect material|fks quality system issues|quality management system|engineering|ecn change|ECN:6164886 - PN:P7000039672 - CDM|ECN:6164886 - PN:P7000039672 - CDM
ZF|100018531|23/04/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|assy|damaged during assembly|Falha de leitura de sensor externo|cutted wire
ZF|100036936|22/04/2005|priority unknown info priority|Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Not performed HFT do to lack of time|unknown info root_cause
Q1|3794920|28/02/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|electrical|sem el.rack|defect locations offshore field|statfjord c|initial direct product problem|function|SCM 57 SFC SEMB malfunction|unknown info root_cause
Q3|7101172|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|mechanical|mechanical components|defect locations offshore field|deepsea trym|initial direct product problem|damages|GFS SCM 05  locking mechanism loosened|Shear pin sheared  suspect over-torque
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTI NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Scratch in seal surf adjacent to o-ring|unknown info root_cause
Q3|7105131|05/01/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|function|SCM M/MFM General|Restrictors should be 1 instead of 2 mm
ZF|100046112|21/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|electronic boards|other eletronic boards|intercompany|singapore|No readings from ex.sensors on SEM B|Follow up in SN300373234
ZF|P6000150910|11/09/2018|priority 3 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Part is not as specification|unknown info root_cause
ZF|P6000068912|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000064909|21/02/2011|priority 2 |Q3|TOTAL|NORTH SEA|ATCO NOTE NOPT NOCO|design|material master error|scm|scm|engineering|engineering error|Wrong size on the o-rings and pins|Wrong size on o-rings  in BOM
ZF|100050383|13/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|conversion approval|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|Company decide to not upgrade el.boards|CAM & IO board not last recommended rev.
ZF|P7000016420|12/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|instrumentation|scm pressure transmitter|other external causes|customer error responsibility|Leitura do PT Não Conforme|Mau funcionamento PT
ZF|100035014|12/08/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm sem el opt component|optical penetrator (insert)|vendor|equipment malfunction|Ormen Lange Leaking Penetrator SEM B|Leakage through optical penetrator
ZE|P6000068912|22/10/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|assembled incorrectly|scm|scm|variance|capture mistake|loose screws on outercan|Operator forgot to torque all bolts.
ZF|P7000024900|07/06/2012|priority 1 |Q3|SHELL|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|engineering|continuous improvement|SEM Internal Pressure at Hyperbaric Test|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOPT NOCO NOTI ATCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Marlim SCM 06|Wrong materials
ZF|P6000037365|16/04/2009|priority 3 |Q3|PETROBRAS|GOM|ATCO NOCO NOTE NOPT|design|drawing error|scm|scm|vendor|design error|HP COV / SCHEMATIC  ISSUE|HP COV / SCHEMATIC  ISSUE
ZD|P6000068770|10/12/2014|priority 2 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage during assembly|scm|scm|engineering|continuous improvement|Damage on ROV Fishtail protection|Damage on ROV Fishtail protection
ZF|P7000039672|19/01/2016|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|machining|burr chips|scm hyd mech components|other hydraulic components|vendor|final inspection error|Plug For Filter With Swarf - PN 7103556|unknown info root_cause
ZF|P7000039672|15/01/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage due to handling|scm hyd mech components|baseplate|other causes damage|damage during transport|ARRANHÕES NA BASE PLATE|unknown info root_cause
ZF|100035013|20/09/2005|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PLUS AND MINUS IS SWITCHED ON DHI|unknown info root_cause
ZF|P7000024191|08/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|interface issue|scm|scm|engineering|continuous improvement|Prob na montagem das capas de PTs|unknown info root_cause
ZD|100016901|02/10/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO|coating plating|coating defect|scm hyd mech components|baseplate|vendor|coating defect|Incorrect coating (B)|unknown info root_cause
ZF|P6000055605|27/12/2010|priority 1 |Q3|SHELL|GOM|ATCO NOPT NOTE NOCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000079433|07/02/2012|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOPT NOCO NOTE|documentation|incorrect certificates records|scm hyd mech components|hydraulic tubing|materials stores|operator error|tubing batch number on zpp list is wrong|Traceability list error  warehouse.
ZB|7104670|24/02/2012|priority 1 |Q1|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|test|function|scm|scm|other external causes|customer error responsibility|GC 204 AMV PT failure (Statoil Heidrun)|Customer Error/responsibility
ZF|100046387|06/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|scm|scm|test|tooling|CITV and MPFM test in FAT|Lack of functional CPI test equipment
ZF|P6000068902|23/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|wiring error outer can|Wiring error.Operator error
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE NOCO NOPT ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 11|Software improvement/correction
ZF|P7000001843|20/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|coating plating|coating defect|scm hyd mech components|locking mechanism|other causes damage|damage from wear and tear|Revestimento|Revestimento danificado
ZF|P7000001621|09/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm|scm|machine shop personnel|operator error|Tube suporte não monta|Usinagem FMC
ZF|P7000016420|24/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage during assembly|scm hyd mech components|hydraulic tubing|other causes damage|damage from wear and tear|Tubo de vácuo|unknown info root_cause
ZF|P7000001621|10/12/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|damage|wear & tear|scm hyd mech components|outer can|materials stores|improper packaging & storage|Vazamento de silicone durante estocagem|Vazamento na bexiga durante estocagem
ZF|P6000148934|30/11/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|other specify in comments|electronic boards|dhi|assembly|other specify in comments|Wrong customer provided DHI card|Wrong customer CPI DHI board installed.
ZF|3805796|19/10/2010|priority 2 |Q3|CONOCOPHILLIPS|unknown info region|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|projects|material error|Material not delivered to plant|Taken into Aberdeen under wrong Project
ZF|P7000000897|31/01/2012|priority 1 |Q3|SHELL|unknown info region|NOPT NOTE ATCO NOCO|assembly|wrong part assembled|scm|scm|assy|operator error|Transformador trocado|unknown info root_cause
ZD|100020278|21/07/2010|priority 1 |Q2|EXXONMOBIL|unknown info region|ATCO NOTE NOCO|damage|damage during assembly|ss compl. & w.over xt general|hydraulic connections fittings|intercompany|kongsberg|INSPECT SCM - DAMAGED COUPLER RISK|Vendor Liability
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE ATCO NOCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 16|Software improvement/correction
ZD|P6000105708|06/11/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|documentation|missing certificates records|scm|scm|vendor|documentation|no approved ats|Vendor : Documentation
ZF|P6000104111|17/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|interface issue|scm sem el opt component|sem mech. components|engineering|dwg error|Hole pattern not fit|Wrong part in SEM assembly BOM
ZF|P6000042308|26/08/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|component error|scm|scm|vendor|unknown info cause_desc|PT18 broken.|See ZF-QN 200139349
ZE|P6000064910|20/06/2014|priority 4 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|MCM mob - Values out of acceptance|HFT procedure corrected
ZF|P6000029747|24/02/2009|priority 3 |Q3|ENGIE|NORTH SEA|ATCO NOTE NOPT NOCO|test|function|scm|scm|engineering|unknown info cause_desc|CPU600 startup problem|Error to be confirmed in QN200124450
ZF|P6000079433|02/01/2012|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOCO NOPT NOTE|assembly|imension (tolerance)|electronic boards|comm.link (power line)|engineering|engineering error|Not able to mount bolt.|BOM not aligned with ASM instruction
ZF|P7000039672|24/11/2016|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO DLFL|damage|damage from corrosion|object types to eng matl class|scm_components|vendor|packaging handling|Contaminação / Contamitation|unknown info root_cause
ZB|100059647|06/03/2010|priority 2 |Q1|LLOG|GOM|NOTE ATCO NOCO|test|component error|scm electrical|i o pcbs|test|damaged during testing|UPT has erratic output|UPT has erratic output
ZF|100030711|02/06/2004|priority 2 |Q3|STATOIL|unknown info region|NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Kommunikasjonssvikt Oseberg J SCM 13|unknown info root_cause
ZF|3787102|16/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly|unknown info damage_desc|scm|scm|other causes damage|unknown info cause_desc|Voided screws P/N 200017922|voided 12.9 screw awaiting replacement
ZF|P6000104116|21/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|machining|position error|scm|scm|vendor|specification not followed|Compensator housing allignment fault|Hole interface error  QN 200414769
ZD|P6000039844|02/09/2009|priority 2 |Q2|unknown info customer_name|unknown info region|NOTE NOCO NOPT|coating plating|painting defect|scm|scm|vendor|packaging handling|(SS) RUSTY ON TOP PLATE AREA|unknown info root_cause
ZE|P6000133916|30/01/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|causes for improvement|documentation|Total request to change oil in SCM|unknown info root_cause
ZF|100052231|15/02/2011|priority 2 |Q3|CHEVRON|GOM|NOTE ATCO NOCO NOPT|change deviation request|process substitution request|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|intercompany|houston|Missing Sign off|Missing Sign Off
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|ECN 7058839 - P7000017839
ZF|P6000088604|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000141559|21/12/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|documentation requirement|other specify in comments|Wrong wiring on SEM.|PO not updated
ZF|100020562|30/11/2009|priority 3 |Q3|BP|GOM|NOTE NOPT NOCO|test|component error|scm|scm|test|unknown info cause_desc|Water in module after hyperbaric.|Strainer  hose and fitting changed
Q3|7104670|12/09/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations offshore field|heidrun tlp|root cause engineering|material fault|SCM DO-board failure|DO150 card malfunction
ZF|P6000088751|13/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000132097|31/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|projects|material error|Too big leakage during SCM leakage test|Design change
ZF|100001156|10/11/2006|priority 4 |Q3|STATOIL|NORTH SEA|NOCO NOTE|assembly test|interface of components issue|scm|scm|vendor audit|unknown info cause_desc|SCM not demobilised after operation|Not demobilised after operation
ZD|100020562|14/03/2009|priority 3 |Q2|BP|GOM|NOCO NOPT ATCO NOTE|documentation|missing certificates records|scm|scm|vendor|specification not followed|MISSING CERTIFICATE OF COMPLIANCE|MISSING C OF C
ZF|100035119|20/08/2004|priority 3 |Q3|PETRONAS|unknown info region|NOPT NOCO ATCO NOTE|assembly test|workmanship general|scm electrical|wiring|assembly test|assembly test error|WRONG ASSEMLING OF EL. RACK|SEM A and SEM B swapped.
ZF|100035013|26/10/2009|priority 4 |Q3|SHELL|unknown info region|NOTE ATCO NOCO|other defect|functional|scm|scm|other causes damage|qn cancelled|Problems with powerline on SCM SEMB|Problems with powerline on SCM SEMB
ZF|P6000105542|10/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN 16|Wrong welding pin defined for man. block
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P6000042968|25/04/2011|priority 1 |Q3|TOTAL|WEST AFRICA|ATCO NOPT NOTE NOCO|damage|damage during transport|scm|scm|other causes damage|damage during transport|PZF-SCM transport damage|unknown info root_cause
ZF|7103233|08/11/2005|priority 1 |Q3|SUNCOR CPI|unknown info region|NOPT NOTE NOCO|assembly test|do not use|scm|scm|engineering|dwg error|12.9 bolts on LP and HP  adapterplates|unknown info root_cause
ZF|100037966|07/02/2006|priority 1 |Q3|BP|unknown info region|NOCO ATCO NOPT NOTE|design|do not use|scm|scm|other causes|no noncompliance|Wrong SEM adresses on control modules|miscommunication within project
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|unknown info root_cause
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte solonoider på ventiler.|unknown info root_cause
ZF|7101937|04/10/2004|priority 2 |Q3|LUFENG|unknown info region|NOTE NOCO ATCO NOPT|vendor|unknown info damage_desc|scm mech w mb|hydraulic manifolds|vendor|material error|Magnetic Lee-plugs in manifoldblock.|Lee-plugs with wrong material
Q1|7103234|19/11/2002|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTI NOPT NOCO|scm rcm|scm|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|SCM TN04I HP Ret.Flowm.unstable readings|unknown info root_cause
Q3|7105597|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|function|FAT TPR-0011497 Sec 9.1.3.m)Acc. critera|Accept criteria not fulfilled.
ZF|100026567|06/02/2004|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|assembly test|miscellaneous|scm hydraulic|other scm hydraulic|engineering|miscellaneous product design errors|SCM 2 Vigdis Ext. rubber pollut.  HPX1/2|unknown info root_cause
ZF|P6000076121|03/11/2011|priority 3 |Q3|CNOOC|unknown info region|NOCO NOTE NOPT ATCO|test|cleanliness|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Chips found inside the HP-Config Plug|Plugs not cleaned by supplier.
ZF|P6000088604|29/06/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|part lost|scm|scm|assy|missing parts|(CDM) Missing API bucket for SCM|Missing API bucket for SCM
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100035013|11/11/2009|priority 4 |Q1|SHELL|unknown info region|ATCO NOTE NOCO|assembly|unknown info damage_desc|scm|sem|other causes damage|cause not found|SUBSEA-Ormen Lange Claim 028 PTs SEMA|To be investigated when SCM is retrieved
ZF|100055762|23/05/2008|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|marking|unknown info damage_desc|scm|scm|assy|unknown info cause_desc|Text height of SCM marking wrong size.|unknown info root_cause
ZF|P7000016420|14/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage due to handling|scm|scm|materials stores|improper handling|PEÇA DANIFICADA|ERRO NO  MANUSEIOERRO NO  MANUSEIO DA PEÇA
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL ATCO NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
Q1|7101172|28/01/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOCO NOPT|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|gullfaks a|initial direct product problem|function|DHPT GFA H-3H unstable in periodes|unknown info root_cause
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM well D-1H PT LP Supp. malfunction|O-ring (PT)
ZF|P6000065886|15/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|design|drawing error|scm hyd mech components|sem bracket|engineering|dwg error|SEM bracket mangler M6 hull for klammer|Design error on DWG
ZB|100020562|25/10/2006|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly test|missed operationassy test|scm electrical|other scm electrical|vendor audit|unknown info cause_desc|SEM A failed on SCM 06 on XT #4|SEM A failed due to high voltage
ZF|7104075|14/09/2005|priority 3 |Q3|SHELL|GOM|NOTE NOPT NOCO ATCO|design|material master error|scm|scm|engineering|engineering error|COV bolts on SCM PN 7104075|BOM list error
Q3|7106268|22/02/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|scm rcm|scm|ext. loc. luanda (angola)|goods receipt|initial direct product problem|function|SCM M 04|unknown info root_cause
ZF|3794920|03/03/2004|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly test|miscellaneous|scm hydraulic|other scm hydraulic|assembly test|assembly test error|Wrong piping to the flushing valve.|Wrong piping on the SCM.
Q2|100016711|20/02/2003|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|electrical|sem powersupply|ext. loc. kos houston|work shop|root cause vendor|material component error|12 volt Power Supply found to be blown|unknown info root_cause
ZF|7102643|21/11/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|one atmosphere canisters|assembly test|assembly test error|SCM 40 ÅSG. L3H SEMA AI/SIO malfunction|Vacuum plug not mounted.
ZF|P6000121393|13/04/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|dbi error|object types to eng matl class|scm|engineering|specification error|RIT: SCM SEM A/B Voltage Out of Range|SCM SEM A/B Voltage Out of Range
ZF|P7000039672|09/12/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|welding|lack of weld|scm hyd mech components|outer can|vendor|specification not followed|Welding is not in accordance with drawin|119863 -Bandak Notodden AS
ZD|100020278|05/09/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|coating plating|incorrect colour coating|scm hyd mech components|baseplate|vendor|operator error|Incorrect coating|unknown info root_cause
Q3|7103233|11/01/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|hydraulic|chemical control valves|ext. loc. st.johns (canada)|goods receipt|initial direct product problem|function|SCM 02P  CIDV 2 does not function|Valve contaminated  ref. QN 200004305
ZF|100037229|10/10/2005|priority 1 |Q3|PETROBRAS|unknown info region|NOCO NOTE NOPT ATCO|assembly test|interface of components issue|scm|scm|vendor|component error|Flange and EC blind plug collide.|Which part is out of tolerance is unknow
Q3|7105130|20/03/2003|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|vendor|root cause assembly test|workshopassembly test error|Pig detector failure on SCM|unknown info root_cause
Q1|7105130|18/01/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM M 02|unknown info root_cause
ZB|P6000080343|03/04/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|other external causes|customer error responsibility|Jubilee Claim SCM 02|"Possible ""dirty"" hydraulic fluid"
ZD|P6000088751|06/03/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|damage|damage during testing|scm|scm|service :|damaged during installation|GWF SCM #3 CPU600 ERRORS|SCM #3 CPU600 ERRORS
ZD|P6000077632|30/04/2015|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|procurement|incomplete kit of parts|scm|scm|intercompany|kongsberg|Missing Lifting Data Plate|Missing Lifting Data Plate
ZB|100051269|10/09/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|test|function|scm|scm|other causes damage|unknown info cause_desc|SEM not working|Internal failure in the SEM A
ZF|P6000068912|29/09/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|design|dbi error|common misc fasteners metric|screw|engineering|dbi error|Missing batch-management on 200017100|Wrong ECN class used.
ZF|7104033|24/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|design|drawing error|scm|scm|engineering|dwg error|Update GA DWG for various project SCM.|Missing information regarding marking
Q3|7104670|02/08/2001|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|test procedure error|USE OF HFT PROCEDURE FOR GFS II FOR HNF|HNF HTF PROCEDURE UNDER REVISION
ZB|100020278|24/10/2006|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly test|function|scm hydraulic|other scm hydraulic|other causes|no noncompliance|SCM Silicone Check Valve did not check|unknown info root_cause
ZF|P6000109194|29/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|LP supply flowmeter not working properly|Not reading below 719ml/min
ZF|100046112|25/08/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOPT NOCO|assembly test|function|scm|scm|engineering|engineering error|PROBLEM WITH UPDATE FROM RS485|Software improvement
ZF|P6000105542|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000093501|12/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|100017305|15/08/2001|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Request to change SCM EC configuration|unknown info root_cause
ZC|7104670|10/08/2004|priority 4 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|vendor|unknown info damage_desc|scm mech w mb|locking mechanisms|vendor|fabrication error|unknown info notification_desc|Wrong paint spec
Q3|7103233|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|product defects for dept.|software|defect locations onshore|inhouse fat|initial direct product problem|function|Feil i config file for flowmeter.|unknown info root_cause
ZF|100016901|02/02/2004|priority 3 |Q3|BP|unknown info region|NOPT NOCO NOTE|service maintenance|unknown info damage_desc|scm electrical|pressure transducers|operation maintenance|expected wear and tear|PT failure|Unknown error. It may be a PT error.
ZF|P7000020444|20/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|imension (tolerance)|scm hyd mech components|sem bracket|vendor|specification not followed|Furação desalinhada|Bracket não monta
Q3|7103233|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|electrical|modems communications|defect locations onshore|efat|initial direct product problem|function|AMV did not close during ESD Level 0|SCM was busy operating chokes
ZF|3794920|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZB|100031223|17/11/2004|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT|assembly test|function|scm electrical|other scm sensors|other external causes|customer error responsibility|SCM 1 GF Diacs DH SEMA instability|Variations within normal specifications
ZF|100030542|20/04/2004|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly test|cleanliness|scm hydraulic|other scm hydraulic|engineering|miscellaneous product design errors|Press. changes can dislodge Rubber Shim|Design error
ZF|100046112|20/12/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly test|interface of components issue|scm|scm|assy|missing operation|Damage on treads on Check Valve w/cap|Threads damaged during testing.
ZF|100035014|30/03/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|machining|position error|scm hyd mech components|outer can|vendor|specification not followed|MCM ROV Bucket out of tolerance|Follow up in ZD QN:200257477
ZD|P6000123495|09/09/2016|priority 2 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|damage|damage during transport|object types to eng matl class|scm|paintshop|paint defect|Transportation Damage & Missing ATS|unknown info root_cause
ZB|100038200|01/02/2008|priority 2 |Q1|BHP BILLITON PETROLEUM AMERICAS  INHOUSTON STOCKING SCM MK II (15K)|unknown info region|ATCO NOTE NOCO|damage|damage during testing|scm electrical|other scm electrical|other causes damage|unknown info cause_desc|EC1 Alignment Key|EC1 Alignment Key
ZF|P6000088604|16/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000029772|24/04/2009|priority 3 |Q3|ENGIE|NORTH SEA|ATCO NOCO NOTE NOPT|damage|unknown info damage_desc|scm|scm|assy|operator error|External handling of SCM|Operator Error
ZF|P7000016420|18/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|missed operation|scm|scm|test|incorrect set up testing|SRT SCM P-55 SN 12|lab test box com fio solto
ZF|7101401|13/06/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO|assembly|interface issue|scm mech w mb|outer can|service :|improper job preparation|MMR - Failure Hose House assembly|unknown info root_cause
ZF|100031223|06/05/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|design|drawing error|scm|scm|engineering|dwg error|Error in drawing.|Update of DWG  see QN200163243
ZF|7103233|20/10/2010|priority 2 |Q3|SUNCOR|unknown info region|ATCO NOCO NOPT NOTE|documentation|procedure process error|scm|scm|qa qs qi|goods receiving inspection error|SCM returned to FMCK on MMT|Goods Receiving Inspection error
ZF|P6000028371|23/10/2008|priority 1 |Q3|SHELL|GOM|NOCO ATCO NOTE|assembly|wrong part assembled|scm|scm|machine shop personnel|lack of training|Manifoldblock missing in iBASElist|error during transition from hand ibase
ZF|P1000018406|13/04/2012|priority 3 |Q3|BP|unknown info region|NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|test|damaged during testing|Hydraulic supply hose rupture|Hydraulic supply hose rupture
Q3|7106268|28/08/2003|priority 1 |Q3|TOTAL|unknown info region|NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Substantial loss of presure on LP A andB|unknown info root_cause
Q3|7104075|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|documentation|Feil i FAT procedure TPR-0011190 rev 4|Feil unner saving av dokumenter
Q3|3794920|21/08/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Ventil som lekker ?|unknown info root_cause
ZF|100016901|18/12/2003|priority 3 |Q3|BP|GOM|NOPT NOTE NOCO|service maintenance|unknown info damage_desc|scm electrical|pressure transducers|operation maintenance|expected wear and tear|PT failure|Unknown error. It may be a PT error.
Q3|7103479|04/02/2002|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations onshore|fat|initial direct product problem|function|FAT results are out of accept criteria|Errors in test procedure
ZB|7104670|23/07/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|other defect|functional|scm|scm|projects|material error|CIDV1 was stuck in close position|unknown info root_cause
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOTI NOCO ATCO|electrical|pressure transducer|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 12 ÅsgA P1-H PT SIV malfunction|unknown info root_cause
ZF|P6000029747|18/11/2008|priority 2 |Q3|ENGIE|NORTH SEA|NOTE NOCO NOPT|test|function|electronic boards|other eletronic boards|test|unknown info cause_desc|DSL communication loss too high|Error outside the SCM (in Topside Eq.)
ZB|P6000064911|10/06/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|electrical|performance|fks quality system issues|product realization|electrical|other specify in comments|Defect Not. 09 - SRMs|cause unknown - no liabiliy for FMC
ZB|100048038|27/04/2009|priority 4 |Q1|AGBAMI|unknown info region|NOTE ATCO NOCO NOPT|test|leakage (fluid)|xmas tree|other xt|test|unknown info cause_desc|Leak out SCM Relief Valve on AGB 20|unknown info root_cause
Q2|7106268|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|material|SCM I 01|unknown info root_cause
Q3|7104670|30/07/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|function|SCM  interface not sending 24v supply.|No fault found at FMCKS
ZF|100048038|18/05/2006|priority 4 |Q3|CHEVRON|WEST AFRICA|ATCO NOCO NOPT NOTE|design|do not use|fks quality system issues|quality management system|assy|missing operation|Incorrect marking on Top plate|unknown info root_cause
Q3|7104670|16/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTI NOCO|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|damages|WOCS  failure in software comm. with SCM|SOFTWARE ADRESSING FAILURE TO SEM-B 520Troubleshooting FMC Kongsberg
ZE|P6000100953|01/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Errors in procedure TST60090648|Procedure corrected  ref. ECN number
ZF|P6000084906|18/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|specification error|computer system software|sw|engineering|engineering error|Not complete SW Rel3|unknown info root_cause
Q1|7102643|20/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOPT NOCO ATCO|electrical|pressure transducer|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 40 ÅsgB Y-3H PT LP supply unstable|unknown info root_cause
ZF|P6000068902|26/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring error|Human error  during assembly
ZF|100058509|19/01/2010|priority 3 |Q3|LLOG|GOM|NOCO NOTE NOPT ATCO|other defect|part lost|scm|scm|intercompany|kongsberg|Missing LP & HP vent to sea caps|Missing LP & HP vent to sea caps
ZF|100020562|08/07/2010|priority 2 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|documentation|missing certificates records|scm|scm|engineering|engineering error|Shipped without QA approval.|Book not signed off on correctly.
ZF|P6000123495|10/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|procurement|incomplete kit of parts|instrumentation|scm pressure transmitter|vendor|specification not followed|Missing support ring & O-ring|Missing support ring & o-ring on PT
ZE|P6000074156|28/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM)Prellude- to blank out the ESRS|Prellude- to blank out the ESRS
ZF|P7000024900|13/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|physical damage|scm hyd mech components|baseplate|materials stores|improper packaging & storage|SCRATH ON BASE PLATE SCM BC-10 (44)|Item not traceable
ZF|P6000105542|26/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|imension (tolerance)|scm hyd mech components|other mechanical components|other causes damage|qn cancelled|Too short screw for the trafo bracket|Screws length is OK for use.
ZF|100052231|03/10/2006|priority 1 |Q3|CHEVRON|GOM|NOTE NOPT NOCO ATCO|assembly test|interface of components issue|scm|scm|engineering|dwg error|AI150 Modification of SoftWare|New release of software on AI150-board
Q3|100017305|04/12/2002|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Lost communication on SEM A|unknown info root_cause
Q3|7104670|06/03/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|TEST SCM PASSER IKKE.|unknown info root_cause
ZF|7102643|01/12/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|vendor|unknown info damage_desc|scm electrical|modem pcbs|vendor audit|unknown info cause_desc|SCM 15 ÅSGA L-4H SEM A Comm. problems|Failed power supplies.
ZF|100018531|04/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|electronic boards|dhi|test|operator error|DHI 108 card damaged.|Wrong wiring
ZE|P6000100953|24/05/2017|priority 2 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Lack of FNCR and SN Creation|unknown info root_cause
ZE|P6000088751|17/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|causes for improvement|lack of training|Wiring Error.|Error might be caused by situation ongoi
ZF|100037428|29/11/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOTE NOPT ATCO NOCO|design|specification error|computer system software|etu sw|engineering|engineering error|Configuaration file is wrong.|unknown info root_cause
ZF|P6000107981|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000068902|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO ATCO NOTE NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 02|Software improvement/correction
ZF|P6000122574|28/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|material error|too small diam inside filter|Filter changed out.
Q3|7105597|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Penetration of sea water in SCM|unknown info root_cause
ZF|P7000039672|03/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|common misc fasteners metric|bolt|assy|operator error|Parafusos da DCV danificados|unknown info root_cause
ZF|P7000001843|22/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm hyd mech components|control valve|other causes damage|damage from wear and tear|Flow meters|Equipamento retornou do campo
Q3|7104670|24/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|function|SCM 08 did not read press/temp.|SIO card upgrade required
ZF|P7000000897|26/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|instrumentation|scm pressure transmitter|vendor|missing parts|PT não conforme.|Missing the metal ring
Q3|3794920|05/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|electrical sensor equipment|electrical penetrators|defect locations offshore field|sleipner loke|initial direct product problem|function|SCM installation  lost sensor readings|ROV pin connector damaged offshore
Q1|7102969|01/10/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOCO NOPT|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|material|Broken bolts|unknown info root_cause
ZE|100020278|02/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|outer can|causes for improvement|documentation|Serrated Washer Verification|Improvement of BOM on repeat review
ZF|P6000076121|09/09/2011|priority 3 |Q3|CNOOC|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|instrumentation|scm flowmeter|assy|operator error|Leakage from O-ring HP flowmeter|O-ring damaged during assembly
ZF|P7000000897|01/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|interface issue|scm hyd mech components|control valve|materials stores|improper packaging & storage|Change over com desvios|unknown info root_cause
ZF|P6000068912|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100030542|23/02/2004|priority 2 |Q3|BAOBAB|unknown info region|ATCO NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Silicone check valve is blinded.|unknown info root_cause
ZF|P6000103208|07/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm|scm|other causes damage|no noncompliance|HP Flowmeter didnt show any value|Particle caused wrong FM reading
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|NOTE NOPT ATCO NOCO|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
Q3|7104670|unknown info defect_date|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|material|Bytte av poppet i koplere. SCM 01|unknown info root_cause
ZE|100036232|15/11/2017|priority 3 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|(LL) WO Shell Pierce OH29 SCM#T11 Pri4|unknown info root_cause
ZB|100050383|05/11/2007|priority 1 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTE|assembly test|interface of components issue|scm|scm|vendor audit|unknown info cause_desc|Tordis 01  HTEM module B|Unstable operational part
ZF|P6000100953|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000064909|21/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring failure|Wiring fault. Human error.
ZF|P6000068912|01/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|unknown info root_cause
ZF|7103233|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|other defect|functional|scm|scm|other causes damage|qn cancelled|unknown info notification_desc|See SN 300162481
ZF|100017278|10/11/2005|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm|scm|other causes damage|unknown info cause_desc|Silicon leakage after refurbishment|Damage caused by assembly
ZF|P6000123495|21/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|function|scm hyd mech components|other hydraulic components|test|operator error|LP Flowmeter and LPr Flowmeter switchet.|Failure not discovered during inhouse
ZF|P6000079984|22/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. testNo SCM failure detected in extend. test
ZB|100001156|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|raw material|defects in material|scm|scm|manufacturing|do not use|Failure on AI card on SEM A  well M-4H|AI card might be of batch with failure
Q1|7101401|22/05/2002|priority 2 |Q1|PETROBRAS|unknown info region|NOPT NOTI NOCO|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|leakage|SCM 4 Marlim HP Leak CVHP Supp. to Ret.|unknown info root_cause
Q3|7101172|03/10/2000|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|deepsea trym|initial direct product problem|leakage|More flow to open SCSSV than normal|Leaking SCSSV (down hole safety valve)
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte solonoider på ventiler|unknown info root_cause
Q3|7104075|24/08/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI|scm rcm|scm|ext. loc. kos houston|goods receipt|root cause other|logisticspacking shipping damage|Shipping Damage to Shell SCM #25|unknown info root_cause
ZF|7104033|17/03/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|test omitted|scm|scm|test|incorrect set up testing|Reduction of mobilization scope|unknown info root_cause
ZF|100020278|16/01/2007|priority 3 |Q3|EXXONMOBIL|unknown info region|NOCO NOTE NOPT ATCO|procurement|vendor did not complete required work|scm|scm|vendor|assembly error|MISSING FILL VALVE PLUG AND SEAL|Missing Fill Valve Plug and Seal
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|unknown info region|NOPT NOTE NOCO|assembly test|function|scm hydraulic|other scm hydraulic|engineering|procedure error|Too high cracing pressure on check valve|Cracing pressure not verified on SCM
ZF|P6000069056|29/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|CVHP 58 & 54 Positions swapped|Assembled on wrong position on M.block
ZF|P6000068902|04/05/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation requirement|part description drawing|object types to eng matl class|scm|documentation requirement|engineering error|CLOV SCM sensor schematic wrong|Error in drawing
ZF|P7000001621|20/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|imension (tolerance)|scm|scm mounting base (scm|other causes damage|cause not found|Desvio de planicidade|unknown info root_cause
ZD|100034440|10/09/2005|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|do not use|scm|scm|vendor|fabrication error|Missing Documentation|Documents errors
Q3|7102969|21/06/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|mechanical|locking mechanism|defect locations onshore|workshop other|initial direct product problem|leakage|Small amount of water in module|Leak from center rod sealing
ZF|7104075|29/09/2005|priority 3 |Q3|MARUBENI|GOM|NOTE ATCO NOCO NOPT|assembly test|do not use|scm|scm|assy|missing operation|missing check valve assembly|Missing check valve assembly
ZB|P6000055605|02/12/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTE|other defect|functional|scm el opt components|other el opt components|vendor|equipment malfunction|Bonga Claim 001 SCM 315|MRM failure
Q3|7100320|24/10/2001|priority 2 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE NOPT|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|function|SCM Hercules malfunc.SEM A/B power inlet|Not yet known
ZF|7105130|31/05/2012|priority 1 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO NOPT|test|missed operation|scm|scm|test|missed operation|To high pressure on valves during hyper|357bar on DCVs during hyperbaric test
ZF|100034440|30/11/2010|priority 2 |Q3|HOUSTON STOCKING MK IV|unknown info region|ATCO NOPT NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P7000016420|19/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|interface issue|scm|scm|qa qs qi|goods receiving inspection error|Revestimento do pino guia não conforme|REVESTIMENTO
ZF|7104075|25/01/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|wear & tear|scm|scm|other external causes|customer error responsibility|Damaged EC Connector|unknown info root_cause
ZB|100049392|05/01/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|leak|scm|scm|other causes damage|cause not found|Leakage on HC supply F2-LP|Cause wiil be determined during repair
ZF|P6000088626|27/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|specification error|scm|scm|engineering|engineering error|CVLP23 is Not operating wrong wiring doc|Specification updated  ref ECN 6176801
ZF|P6000068902|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000105542|06/08/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|wrong part assembled|scm|scm|test|damaged during testing|SCM router cards damaged|Error engineering  followed up 200394337
ZF|100017278|27/02/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm|scm|other external causes|customer error responsibility|SCM exposed with too high pressure|unknown info root_cause
ZE|7102969|25/04/2005|priority 3 |Q3|MOBIL EG|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|(Change to ZF)|unknown info root_cause
ZE|P6000122626|09/07/2018|priority 3 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM  Updates to Agbami 615 Test procedur|unknown info root_cause
ZF|100015314|13/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|Incorrect SESI described in procedures|Error in documentation.
ZB|100038200|27/03/2009|priority 3 |Q1|SHELL|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm electrical|i o pcbs|other causes damage|cause not found|Loss of Communication SEM-B WELL-3|Cause not found at this time
ZE|100035013|27/03/2015|priority 1 |Q3|SHELL|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|compensator|causes for improvement|documentation|SCM silicone oil leakage|Silicone bladder assembly prd updated
ZB|P7000002082|02/05/2017|priority 3 |Q1|PETROBRAS|unknown info region|NOTE ATCO NOCO|other defect|functional|object types to eng matl class|scm|other causes damage|cause not found|Mecanismo de travamento inoperante|Causa não encontrada
ZF|100037965|23/11/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|change deviation request|process substitution request|ss intervention running tool|scm running tool|documentation requirement|other specify in comments|Deviation Request: SCM Retrieval with LU|ICP calls for retrieval w/ MRT+LU and cl
ZF|P7000039672|13/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Trafo sem marcação de alinhamento|FMC KONGSBERG SUBSEA AS
ZF|100018531|21/12/2016|priority 3 |Q3|SHELL|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during assembly|scm hyd mech components|other hydraulic components|assy|damaged during assembly|MMR - Water on Silicone Sample|O-ring damaged during assembly
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 20|Investigate Coupler Rotation-BPAT SCM 20
ZD|P6000055605|20/01/2012|priority 3 |Q2|SHELL|GOM|NOPT NOCO ATCO NOTE|test|function|scm|scm|intercompany|kongsberg|ISSUE WITH SCM CONVERSION|Issue with SCM Conversion
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZE|P6000098616|30/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|clear description of test in ASY60044250|Already proposed in a existing QN
ZF|P6000116360|09/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|other defect|functional|scm|scm|other causes damage|no noncompliance|Deviations from TR1233 ver 5 for SCM|QN based on comlience with TR requir.
Q3|7105130|06/02/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|scm rcm|scm|ext. loc. luanda (angola)|goods receipt|initial direct product problem|operation & maintenance manual (omm)|SCM M General|unknown info root_cause
ZF|P7000039672|23/06/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|wrong part assembled|scm el opt components|el. connector|vendor|material error|Conjunto de conector c/ mangueira trocad|unknown info root_cause
ZF|100055762|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZD|P6000084242|08/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PARTNUMBER|INCORRECT PARTNUMBER
Q3|7105128|09/02/2000|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|mechanical|locking mechanism|defect locations onshore|workshop other|initial direct product problem|function|SCM P 04|unknown info root_cause
ZE|P6000043714|21/09/2009|priority 2 |Q3|PETROBRAS|GOM|NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm mounting base (scm|causes for improvement|process procedure ineffective|Communication between Houston and Norway|unknown info root_cause
ZE|P6000093498|13/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|variance|capture mistake|Water in Silicone sample|See attached RCA.
ZE|7103233|22/10/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|causes for improvement|process procedure not being followed|EC`s in baseplate not grounded.|Operator did not follow DWG/BOM
ZF|100055762|28/01/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|missing batch numbers|change to batch management
ZF|100020562|03/08/2004|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly test|function|software fks provided|sem|other causes|miscellaneous|SCM Software timing error|Software error
ZF|P6000062990|21/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|wrong part assembled|scm|scm|vendor|wrong part delivered|Wrong DHI board|DHI114 delivered instead of DHI117
ZF|P6000042969|15/06/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOPT ATCO NOTE NOCO|test|missed operation|scm|scm|assy|operator error|Error during pressure test.|Human mistake not discovered before FI
ZF|P6000069056|26/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|documentation|procedure process error|electronic boards|comm.link (power line)|other causes damage|no noncompliance|MRMS MAC ADRESSE|Untrained Opr. / unclear procedure
ZF|100048038|05/06/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|NOPT NOTE ATCO NOCO|assembly test|function|electric products|electrical connector|assy|manufacturing engineer erorr|Spare connection to be verified|Bad connection in spare connector
ZF|7103233|23/10/2006|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|damage|wear & tear|scm|scm|vendor audit|unknown info cause_desc|TNO SCM 11P HOST A SEM B malfunction|SEM B electronic card failure
ZF|P7000039672|28/12/2015|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|unknown info notification_desc|unknown info root_cause
ZB|7102969|29/10/2009|priority 1 |Q1|MOBIL EG|unknown info region|NOCO ATCO NOTE|test|function|scm electrical|penetrator|other causes damage|damage from wear and tear|09-MEGI-033 Unable to establish comms|09-MEGI-033 Unable to establish comms
ZF|P6000067533|14/02/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm sem el opt component|other scm sem el opt components|engineering|procedure error|Wrong in the Inhouse testing Procedure|Wrong in the Inhouse testing Procedure
ZF|P6000098616|27/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|documentation|procedure process error|scm|scm|engineering|specification error|HS CAN bus grounding error on CPU card|ISO GND missed in wiring specification
ZF|P6000068924|31/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Inhouse procedure is not corrected|Inhouse procedure wrong.
ZF|P7000001621|18/10/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|imension (tolerance)|scm|scm|vendor|specification not followed|Problemas dimensionais.|causa ainda não definida
ZF|P6000028371|16/09/2008|priority 3 |Q3|SHELL|GOM|NOTE NOPT NOCO|other defect|unknown info damage_desc|scm|scm|test|unknown info cause_desc|Wrong SW on SEM during Inhouse|unknown info root_cause
ZF|P7000039672|28/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|component error|electronic boards|dhi|test|missed operation|Falha no teste DHI Transparent Link|unknown info root_cause
ZF|P7000001621|28/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage due to handling|scm|scm|other causes damage|damage from wear and tear|Outer can amassada|unknown info root_cause
ZF|P7000024191|14/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|scm|scm|test|incorrect set up testing|SEM 600 Test Box não conforme.|unknown info root_cause
ZF|100037966|25/04/2006|priority 3 |Q3|BP|unknown info region|NOCO ATCO NOPT NOTE|machining|inside diameter error|scm|scm|vendor|fabrication error|Problem Assemble blindplug  returnfilter|error with hole F61
ZF|100036936|26/01/2005|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOPT NOCO|assembly test|interface of components issue|scm|scm|engineering|engineering error|Protection Ring does not fit SCM|Slot not updated after change of N2 port
Q3|100017305|04/03/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|First SCMs with standard DigiTron 12-pin|unknown info root_cause
ZF|P6000066700|13/09/2011|priority 1 |Q3|HOUSTON STOCKING V2|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Missing HC in SCM OKONO|Human error  process not maintained
ZF|100037229|16/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|wear & tear|scm|scm|vendor|material error|Brazil / Unauthorized Valve Movement|Defective RAM chip
ZF|P6000068912|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000088604|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000068912|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update SCM PSM - Luanda Workshop|Update is followed up in QN 200439169
ZF|P7000016420|16/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|component error|electronic boards|other eletronic boards|test|improper handling|Conector J4 da placa TIF da eletronica B|unknown info root_cause
ZE|100048038|05/02/2018|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|SCM  Update to documentation|Update of DOC and BOM.
ZF|P6000043714|26/10/2010|priority 3 |Q3|PETROBRAS|GOM|NOTE ATCO NOCO|documentation|missing certificates records|scm|scm|other causes damage|no noncompliance|Missing Engineering Sign offs|No non compliance
ZF|P7000008275|07/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|imension (tolerance)|scm|scm mounting base (scm|assy|manufacturing engineer erorr|Dog com interferência com o canal do nut|Porcas com dimensões erradas
ZF|100036936|29/12/2004|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Marking of hydraulic lines|unknown info root_cause
ZF|100020562|14/02/2006|priority 2 |Q3|BP|GOM|ATCO NOCO NOPT NOTE|assembly test|function|scm|scm|vendor|component error|FAILURE TO OPPERATE TO PRD REQUIREMENTS|CHECK VALVE FAILS TO OPERATE CORRECTLY
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|unknown info region|ATCO NOCO NOTE|change deviation request|conversion approval|scm|scm|intercompany|kongsberg|SCM Change Hydraulic Fluid|SCM to be reflushed
Q3|7102643|20/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations offshore field|viking poseidon|initial direct product problem|leakage|SCM hydraulic leak  line 17  well I-4H|Check valvefitting damaged when handling
Q3|7103905|08/11/2001|priority 3 |Q3|AGIP|unknown info region|NOTI NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|The SCM is leaking silicon|unknown info root_cause
ZF|100046112|11/08/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Problem with RS485 sensors probably SW|unknown info root_cause
ZF|P6000074156|23/01/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|documentation|procedure process error|fks quality system issues|measuring analysis & improvement|engineering|procedure error|DHI 205 acceptance criteria wrong.|Typing error in TST60070027&TST60070028
ZF|P7000039672|19/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|RESÍDUO ENCONTRADO NO PLUG FOR FILTER|unknown info root_cause
Q3|7103233|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|product defects for dept.|software|defect locations onshore|inhouse fat|initial direct product problem|function|Error message from SCM.|unknown info root_cause
ZF|100046387|11/06/2007|priority 1 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|design|r & d error|scm|sem|engineering|engineering error|No communication with SEM A or SEM B.|Update SW
Q1|7101172|05/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM S/N 11 G-2H GFA PT HP Funct. malfunc|Top of PT is off
ZF|P6000055605|23/03/2012|priority 3 |Q3|SHELL|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|vendor|clarification|Unstable comm. with SEM B in FAT|LNCS630 error  follow-up by QN200263019
ZF|P7000024191|23/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|wrong part assembled|scm|scm|other causes damage|cause not found|Coupler de supply fora da revisão atual|ECN não implementada
ZF|100030542|03/12/2007|priority 1 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOTE ATCO NOPT NOCO|documentation|incorrect user documentation (customer)|electronic boards|dhi|engineering|procedure error|Pressure reading was not the correct val|Wron limits in test procedure
ZF|P6000039844|21/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|physical|scm|scm|engineering|engineering error|(SS)SCM - Product Improvement|Marginal design on silicone compensator
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 13|Software improvement/correction
Q3|7102643|31/08/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|electrical|sem el.rack|defect locations offshore field|åsgard a|initial direct product problem|function|No comms with WEPS sensors  well Y2-H|FMCKS: No fault found on SEM B.
Q3|100017305|06/02/2003|priority 3 |Q3|STATOIL|unknown info region|ATCO NOCO NOPT NOTI|mechanical|outer can|defect locations onshore|workshop other|initial direct product problem|leakage|Ruptured compensator bladder|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOPT NOTI|mechanical|mechanical components|defect locations offshore field|campos basin|initial direct product problem|material|Oppgrader Marlim 05-ALFA til 05-GAMA|unknown info root_cause
ZF|100046112|25/08/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOCO NOPT ATCO|assembly test|function|scm|scm|engineering|engineering error|PROBLEM WITH UPDATE FROM RS485|Software improvement  see ECN 6006365
ZF|100048038|11/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|ATCO NOTE NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|materials stores|improper packaging & storage|SCM SILICONE CONTAMINATION|SILICON CONTAMINATION
ZF|100037427|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|scm|scm|test|operator error|Valves operated with too high pressure|DCVs operated with too high pressure.
ZF|100037966|26/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|functional|scm el opt components|other el opt components|other causes damage|damage from wear and tear|P11 SCM -Communications Fault Offshore|Possible Wear and Tear
ZF|P6000126219|25/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|assembled incorrectly|object types to eng matl class|scm|electrical|miswired internally|Wiring issue on LNCS|Wiring issue on LNCS
ZF|100058509|22/02/2010|priority 3 |Q3|LLOG|GOM|NOCO NOTE NOPT ATCO|design|procedure error|scm|scm|intercompany|kongsberg|Choke Quick Move Command Issue|Choke Quick Move Command Issue
ZF|100030665|07/02/2006|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO ATCO NOPT|assembly test|function|scm|scm|other causes|no noncompliance|PRESSURE IS INCREASING ON HP RTN SYSTEM|leakage within acceptance criteria
ZF|P6000103208|03/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm|scm|assy|operator error|Wring fault for sensors on EC9 10 and 11|Wiring not acc. to specification
ZF|P7000000897|20/10/2016|priority 3 |Q3|SHELL|unknown info region|NOPT ATCO NOCO NOTE|assembly|misalignment interface error|scm mech w mb|outer can|documentation requirement|process step missing|MMR - Outer Can Closure Failure|lack of documentation for process
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000039672|08/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|dbi error|hydraulic distribution|other hydraulic components|engineering|ecn change|ECN  6147855 - PN  P7000039672|ECN
ZF|P7000039672|06/05/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|other defect|part lost|scm hyd mech components|hydraulic coupler|vendor|missing parts|COUPLER SEM O-RING|unknown info root_cause
ZF|P6000042969|18/06/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|engineering|engineering error|CV9 to be tested| Procedure error.
Q3|100005667|06/02/2001|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|transocean searcher|initial direct product problem|leakage|HXT bore test leak trough SCM ret.to sea|unknown info root_cause
ZF|P6000104116|01/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|machining|surface finish error|scm|scm|vendor|operator error|Damaged sealing surface|Surface damage during modification work
ZB|P6000088751|15/04/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|documentation|incorrect certificates records|scm|scm|qa qs qi|documentation error|WEL  SCM  Documentation Error|unknown info root_cause
ZF|P6000069056|20/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring on EC4  mislabeled-Outercan test|Opr.failure during wiring & marking
ZD|100049000|22/07/2010|priority 3 |Q2|BP|GOM|NOCO ATCO NOTE|other defect|part lost|scm|scm|intercompany|kongsberg|Missing vent cap on BPAT SCM 23|Missing vent cap on BPAT SCM 23
ZE|P7000024900|05/04/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|process procedure not being followed|RCA|Conectores de topo em posições erradas
Q3|7103233|08/02/2002|priority 2 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|NOCO NOTI ATCO NOPT|mechanical|locking mechanism|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|Locking mech pin broke/SCM refurbishment|Suspect damaged during offshore handling
Q3|100016110|01/05/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM communication Address|unknown info root_cause
ZF|100025661|27/01/2010|priority 3 |Q3|SHELL|GOM|NOPT NOTE NOCO ATCO|test|component error|scm|scm|other causes damage|damage from wear and tear|Shell SCM 81 CPU warranty work|Shell SCM 81 CPU warranty work
ZF|P7000008275|27/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|test|incorrect set up testing|Gráfico do Labview|Falha no Labview
ZF|P6000063531|11/04/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|missed operation|object types to eng matl class|scm|test|other specify in comments|Not able to perform E&M-Probe test.|CPI test equipment not available
ZF|3812476|21/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|damage|damage during testing|scm|scm|test|damaged during testing|Defect rectifier bridge and diode  SEM B|FMC Test: Damaged during testing
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM MAN/SIV 04|Software improvement/correction
ZF|P6000104112|09/12/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|component error|scm hyd mech components|other mechanical components|vendor|specification not followed|water found in silicone sample|Follow-up QN 200476490
ZF|P6000083428|18/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|dwg error|GA dwg error|GA dwg missmatch (nameplate hi WP error)
ZF|7101401|26/09/2013|priority 1 |Q3|PETROBRAS|unknown info region|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|test|tooling|MMR - SEM A not comm. Hyperaric Test|EC connector not mouting correctly
ZF|100020562|09/03/2004|priority 4 |Q3|BP|GOM|ATCO NOPT NOCO NOTE|service maintenance|unknown info damage_desc|scm electrical|other scm electrical|other external causes|customer error responsibility|SCM accidentally dropped with X-mas Tree|Handling error
ZF|P7000016420|20/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm hyd mech components|sem bracket|vendor|packaging handling|Arranhão na Bracket.|unknown info root_cause
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT ATCO NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 05|Software improvement/correction
ZF|P6000063632|20/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|gas leak test not acording to LWI|Procedure error.Engineering
ZF|100020562|05/01/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|test omitted|scm|scm|other causes damage|unknown info cause_desc|All Tests In Procedure Not Completed|All Tests In Procedure Not Completed
ZF|P7000016420|28/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|coating plating|coating defect|scm hyd mech components|locking mechanism|other causes damage|cause not found|Revestimento não conforme|unknown info root_cause
ZF|P6000068924|31/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring feil på EC2|Incorrect wiring by operator
Q3|7102969|30/09/2002|priority unknown info priority|Q3|MOBIL EG|unknown info region|NOTI NOPT NOCO|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|material|Anode problem on SCM|The use of anodes on SCM's (Michael May)
ZF|7104670|04/07/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|service maintenance|unknown info damage_desc|scm electrical|rov el. connectors|assembly test|assembly test error|Electronic failure|1)wrong connection  2)loose bolts
Q3|7105128|05/06/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM P 03|unknown info root_cause
ZF|P6000029772|31/05/2013|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO ORAS NOTE|test|missed operation|test and transportation|other scm test & transport equipment|engineering|specification error|SRM software not up to date|Specification error
ZF|P6000058949|07/12/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|marking|marking content error|scm hyd mech components|outer can|materials stores|operator error|Error on GA  and name plate|Human error.
Q3|7105128|05/06/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM P 02|unknown info root_cause
ZF|100035118|17/08/2004|priority 2 |Q3|WOODSIDE|unknown info region|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc| DIFFERENCE OF COUNTS IS TO HIGH|unknown info root_cause
Q3|100017305|02/10/2002|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|design specification error|Connectors demates before guiding|unknown info root_cause
ZF|P6000088614|02/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|machining|surface finish error|scm hyd mech components|other mechanical components|vendor|specification not followed|Error in in flow on line 5 and 24|Suface finish outside SPC
ZF|100017278|29/09/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|test|component error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Loose lee plug on blind plate.|Not enough friction in lee plug
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|scm rcm|scm|defect locations offshore field|shell alliance gom|initial direct product problem|function|SCM Communication problems offshore|timing problem on modem boards
ZF|P7000001621|11/05/2015|priority 1 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOPT NOCO|machining|angle error|scm mech w mb|scm mounting base|machine shop personnel|operator error|MMR - Base Plate|unknown info root_cause
ZF|100017997|12/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|dbi error|scm|scm|engineering|engineering error|BOM error for SN 05 and  SN 06|BOM not correct for repeat orders on TH.
ZF|P6000074855|07/12/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|electronic boards|comm.link (power line)|test|missed operation|Lacking XML-file for prosject|Missing XML-file
ZF|P6000088751|07/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|cleanliness|scm|scm|test|incorrect set up testing|Contamination of HP lines in SCM|Contamination of HP lines in SCM
ZE|P6000088614|04/10/2017|priority 3 |Q3|ENI|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|documentation requirement|error in document spec|Errors in HFT60078748 for SD2 SCM|Error in HFT procedure
ZF|P6000105542|08/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|missed operation|scm|scm|test|missed operation|Unable to perform test according to HFT|unknown info root_cause
ZF|P6000064909|20/06/2011|priority 3 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE NOPT|test|component error|test and transportation|subsea power & communication test unit (|test|damaged during testing|No output voltage from SPCTU|Damaged during testing
ZE|7100320|03/09/2003|priority 2 |Q3|PETROBRAS|unknown info region|NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|scm mech w mb|one atmosphere canisters|accepted &|do not use|SCM 09 HERC. Sensor mismatch A/B|unknown info root_cause
ZF|100030542|31/03/2006|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|design|do not use|ss intervention running tool|scm running tool|vendor audit|unknown info cause_desc|SCM damaged in transit|Procedure not followed
Q3|7102643|17/10/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM upgrades after removal of outer can|unknown info root_cause
Q3|7100320|02/12/1999|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 13-GAMA til 13-OMEGA|unknown info root_cause
Q1|7105129|17/02/2003|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SITE QUERY: RESISTANCE 470 OHM MISSING|unknown info root_cause
Q3|3812476|04/02/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|electrical|pressure transducer|defect locations offshore field|transocean prospect|initial direct product problem|function|Well D2T2H  SCM SCSSV PT 'over range'|SCM PT defective/SCM recovered
ZF|100035118|06/01/2005|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|unknown info notification_desc|unknown info root_cause
ZF|P6000080733|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
Q1|3801623|unknown info defect_date|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|product defects for dept.|scm|defect locations onshore|workshop|initial direct product problem|material|Compensator and accumulator are loose|Missing screws/poor control at KOS
ZF|100030542|27/09/2005|priority 3 |Q3|CNR|unknown info region|NOPT NOTE NOCO|damage|unknown info damage_desc|sensors|scm pressure transmitter (pt)|vendor audit|unknown info cause_desc|Failure on PT11|SN 300096773 - PT11 failed in SCM 07
ZF|100035400|19/01/2006|priority 3 |Q3|HESS|GOM|NOPT NOTE NOCO ATCO|design|user documentation procedures|scm|scm|vendor audit|unknown info cause_desc|HFT DOC NOT IN ACCORDANCE WITH DAT FILE|HFT DOCUMENT ERROR
ZF|7105128|10/09/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|damage|wear & tear|scm hyd mech components|other mechanical components|qa qs qi|documentation error|Lack of spares - Concession by Client|unknown info root_cause
Q3|7103233|14/03/2001|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTI|hydraulic|hydraulic control valves|ext. loc. st.johns (canada)|work shop|root cause engineering|test procedure error|Suspect SCM HP rtn was over pressured|FMC test procedure error has damaged SCM
Q3|7100320|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Skifte solenoider ventiler sn. 12|unknown info root_cause
ZF|100056261|23/06/2010|priority 2 |Q3|MURPHY|WEST AFRICA|ATCO NOTE NOCO NOPT|documentation|procedure process error|scm|scm|other causes damage|cause not found|Missing sign offs|unknown info root_cause
ZB|100020562|26/01/2007|priority 3 |Q1|BP|GOM|NOCO NOTE NOPT ATCO|assembly test|function|scm electrical|pressure transducers|vendor|component error|Low pressure value observed on the AMV.|Internal PT's failed
ZF|100051991|12/09/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|damage|damage during transport|scm|sem|vendor audit|unknown info cause_desc|Fell from the truck|Handling
ZF|P6000103208|26/03/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Hydraulic leakage LP return flow meter|O-ring not in position during FMassembly
ZB|100020562|11/05/2010|priority 3 |Q1|BP|GOM|NOCO ATCO NOTE|assembly|interface issue|scm mech w mb|locking mechanisms|assy|operator error|Over torqued to the skid|Over torqued to the skid
ZF|100037966|14/03/2005|priority 3 |Q3|BP|unknown info region|NOTE NOPT NOCO ATCO|assembly test|do not use|scm|scm|engineering|engineering error|DHI IS WRONG WIRED|unknown info root_cause
Q1|7102969|27/09/2002|priority 1 |Q1|MOBIL EG|unknown info region|NOCO ATCO NOTE NOPT|electrical|modems communications|defect locations offshore field|pride africa|initial direct product problem|function|SCM Comms failure  Well shut down|Electr. failure within the SEM(S.Tatum)
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL ATCO NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|7104075|29/07/2005|priority 3 |Q3|MARUBENI|GOM|NOTE NOCO ATCO NOPT|damage|damage during transport|scm|scm|assy|missing operation|DAMAGE TO EC7 CONNECTOR|Unknown cause of damage
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Not performed HFT do to lack of time|unknown info root_cause
ZF|P6000064909|30/05/2011|priority 3 |Q3|TOTAL|NORTH SEA|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm|scm|test|operator error|Leakage during hyperbaric|Hose clamp was not tightened
ZB|P6000042970|07/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO ATCO NOTE NOPT|other defect|functional|scm|scm|engineering|continuous improvement|SCM MAN/SIV #2|Software improvement/correction
ZF|100025661|06/10/2005|priority 3 |Q3|SHELL|GOM|NOTE ATCO NOPT NOCO|assembly test|function|scm|scm|vendor|component error|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|Choke close command error
Q1|7104075|unknown info defect_date|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|mechanical|outer can|defect locations onshore|customer goods receipt|initial direct product problem|leakage|Skade i pakningsflade i ytterkande|unknown info root_cause
ZF|100049000|19/07/2011|priority 3 |Q3|BP|unknown info region|ATCO NOTE NOCO NOPT|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100037428|13/09/2005|priority 1 |Q3|TOTAL|WEST AFRICA|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Return compensator retest SCM P03|unknown info root_cause
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PT adapter plate is loose|unknown info root_cause
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Refurbishment - Bytting av PT'er.|unknown info root_cause
Q3|7104670|26/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|Tilbakekalt modul (SIO-kort)|unknown info root_cause
Q3|7104670|24/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|function|SCM 10 did not read press/temp.|SIO card upgrade required
ZB|100050519|16/10/2009|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|damage during transport|scm|scm|other causes damage|damage during transport|Silicon leak on SCM Sn 07|Leaking SCM in box received in Congo
Q3|7104670|14/08/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|scm rcm|scm|defect locations onshore|montasje|root cause engineering|test procedure error|USE OF HFT PROCEDURE FOR GFS II FOR HNF|HNF HTF TEST PROCEDURE UNDER REVISION
Q3|7103233|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|hydraulic|accumulators|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|LP and HP Return Pressure Compensation|Review of requirements
ZF|P6000069056|17/11/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|physical|object types to eng matl class|scm|other causes damage|cause not found|Silicone leakage on EC 7|Silicone leakage on EC 7
ZF|100016901|04/04/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|assy|missing operation|RIT failed|RIT failed
ZB|P6000042969|31/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 16|Software improvement/correction
ZB|100052134|17/12/2007|priority 2 |Q1|PETROBRAS|GOM|ATCO NOPT NOTE NOCO|damage|wear & tear|scm electrical|processor pcbs|vendor audit|unknown info cause_desc|Communication Failure|Random failure on electronics component
ZF|P6000093498|24/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (gas)|scm|scm|test|damaged during testing|Leakage in EC|unknown info root_cause
Q3|100018600|24/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|The centre rod is slow to operate|unknown info root_cause
ZF|100050519|02/04/2013|priority 2 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE|damage|damage from corrosion|scm|scm|engineering|procedure error|Findings on GR Inspection in Congo|MF-0000020212 updated with extra step
ZD|P6000080343|23/08/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|damage|damage during transport|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|vendor|damage during transport|CRATE DAMAGED|CRATE DAMAGED
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|material|Bytting av solenoider på ventiler.|unknown info root_cause
ZD|100025661|29/08/2007|priority 3 |Q2|SHELL|GOM|NOPT NOCO ATCO NOTE|assembly test|function|scm|scm|vendor|test error|SCM Failed HFT|SCM Failed HFT
ZF|100037966|31/08/2005|priority 3 |Q3|BP|unknown info region|NOTE NOCO ATCO NOPT|assembly test|missed operationassy test|scm|scm|assy|operator error|HIGH PRESSURE DISCOVERED ON RTN. LINE|Return hose not properly connected
ZF|100067526|11/01/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|obsolescence issue:&|not available|test and transportation|other scm test & transport equipment|other external causes|customer error responsibility|Not able to perform DHI118 on MOB|Customer don't have available test equip
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000074156|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000068902|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Update SCM HFT|Update is followed up in QN 200439169
ZF|P7000024191|17/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|test omitted|scm|scm|test|incorrect set up testing|SRT Global 7 can bus and Serial Line S2|Lab test box with problem.
ZF|100056443|17/08/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|NOTE NOCO|test|missed operation|wocs|other wocs products|test|missed operation|SCM fault on B-communication.|unknown info root_cause
Q3|7102643|20/03/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations onshore|workshop|initial direct product problem|operation & maintenance manual (omm)|SCM CDIV not closed evaluate OMM|unknown info root_cause
ZF|100037428|24/11/2006|priority 1 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE|damage|damage during testing|scm|scm|other causes|qn cancelled|DH gauge card failure|Activity transferred to SN300117780
ZB|100048038|03/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|NOTE NOCO|test|function|scm electrical|pressure transducers|other causes damage|cause not found|SCM #14 PT16 SEM A & B FAILURE|SCM #14 PT16 SEM A & B FAILURE
ZF|100026567|28/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|TUBE TO HP ACCUMULATOR IS BENT WRONG|unknown info root_cause
ZF|P7000024191|17/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
Q3|7103233|06/03/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|Low temp. qual.test results not approved|Tests out of limits and some not done
Q3|7105131|01/02/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|ext. loc. luanda (angola)|goods receipt|initial direct product problem|documentation|SCM M/MFM General|unknown info root_cause
ZF|100050519|12/06/2006|priority 3 |Q3|MOHO BILONDO|unknown info region|NOTE ATCO NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|engineering|engineering error|Nitrogen in silicon after hyperbaric.|no specification of required thread
ZF|100025661|12/07/2006|priority 3 |Q3|SHELL|GOM|NOPT NOCO ATCO NOTE|assembly test|missed operationassy test|scm|scm|assy|missing operation|HFT STEP CAN NOT BE EXECUTED|Cable Length Simulator Availability
ZF|P6000055605|27/12/2010|priority 2 |Q3|SHELL|GOM|NOCO ATCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|100048038|21/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT ATCO NOCO|assembly test|function|scm|scm|other causes|no noncompliance|Problems with valve operation in tank.|Test Tank had loose fitting
Q3|7104075|28/06/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Refurbishment of Shell SCM 07|unknown info root_cause
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
ZF|P7000039672|12/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|physical damage|scm hyd mech components|sem bracket|assy|operator error|Dano na SEM Bracket|unknown info root_cause
ZF|P6000080733|09/01/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100017997|19/01/2007|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly test|function|scm electrical|hydraulic flow meters|manufacturing|programme error|IWOCS POD did not register any flow|ETU eror with SEM B SCM
ZB|100037965|03/05/2013|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|missed operation|scm|scm|test|operator error|BP SCM w/ wrong sofware version|Sofware version not updated.
ZF|P7000039672|19/01/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|common misc fasteners metric|screw|vendor|final inspection error|Parafuso da válvula danificado|unknown info root_cause
ZF|P6000104115|23/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|scm hyd mech components|sem bracket|vendor|clarification|Wrong drilling of center hole of trafo|Follow-up against vendor by QN 200384061
ZF|P7000001621|29/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|other causes damage|damage from wear and tear|Tampa hose house não casando.|Equipamento retornou do campo
Q3|100018532|18/12/2002|priority 3 |Q3|SHELL|unknown info region|NOTI NOPT ATCO NOCO|scm rcm|scm|defect locations onshore|customer goods receipt|root cause engineering|other product design error|Ruptured compensator bladder|Inner tube not designed for SCM 200
ZF|100048038|12/05/2006|priority 3 |Q3|CHEVRON|WEST AFRICA|NOPT NOCO NOTE ATCO|assembly test|do not use|scm|scm|vendor audit|unknown info cause_desc|Damaged treads on screw and nut|Damaged treads on the screw and nut
Q1|100018531|04/10/2002|priority 2 |Q1|SHELL|unknown info region|NOCO NOTI NOPT|electrical sensor equipment|electrical pin connetors|def. loc. testing (not int. scm)|it (integration test)|root cause vendor|assembly fabrication test error|SCM 3 Bijup.& Salema 12pin Tronic malf.|unknown info root_cause
ZF|3794920|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic couplers|other causes|miscellaneous|Leakage on hydra. coupler on SSP SCM 61|Leakage from poppet
Q1|7105129|13/03/2002|priority 3 |Q1|TOTAL|unknown info region|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations offshore field|pride africa|initial direct product problem|function|SCM 02 Girassol  SEM A malfunction|lost auto update on SCM line A.
ZF|P6000068902|14/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|procurement|incomplete kit of parts|scm|scm|vendor|specification not followed|protection caps missing from SCM|PROTECTION CAPS NOT SUPPLIED
ZD|100037427|26/03/2009|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|missing certificates records|ss compl. & w.over xt general|tree assembly|vendor|operator error|CERT ISSUE|VL - Missing certs
ZF|100048038|22/11/2006|priority 1 |Q3|CHEVRON|WEST AFRICA|NOTE ATCO NOPT NOCO|assembly test|assembled incorrectly|scm|scm|assy|operator error|External leak from COVLP|fittings not tight & displaced o-ring
Q1|7102643|20/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTI|electrical|modems communications|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 48 ÅsgB J-3H no comm. SEM A|unknown info root_cause
ZF|P6000101955|25/02/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|missing certificates records|scm|scm|materials stores|improper handling|transportation notice unreadable|unknown info root_cause
ZB|7104670|14/11/2011|priority 2 |Q1|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|qa qs qi|operator error|Mobilisation maintenance not performed|SCM not mob. acc. to requirements
ZF|100037965|11/03/2009|priority 1 |Q3|BP|unknown info region|NOCO NOTE|other defect|functional|scm|scm|other causes damage|cause not found|Loss communication on SEM B|unknown info root_cause
ZF|P6000069056|05/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|object types to eng matl class|scm|test|other specify in comments|Unable to perform test according to HFT|Lack of necessary test equipment.
Q3|100018082|13/02/2002|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations onshore|fat|initial direct product problem|function|HYDR FLOW RESTRICTION IN QDV CIRCUIT|unknown info root_cause
Q3|3794920|16/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|function|PT values change when wires are moved|unknown info root_cause
ZF|P6000088751|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000043714|15/04/2011|priority 1 |Q3|PETROBRAS|GOM|NOPT ATCO NOTE NOCO|test|function|scm|scm|other external causes|customer error responsibility|Testing to recreate failure per FNCR|Testing to address offshore failure
ZF|P6000125394|09/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|procurement|incomplete kit of parts|instrumentation|scm pressure transmitter|vendor|specification not followed|Missing support ring & O-ring|unknown info root_cause
ZF|100064910|04/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|assembly|interface issue|scm|scm|engineering|continuous improvement|Better design to get easy closing  SCM|Issue will be followed up in QN200456671
ZD|P6000028371|04/08/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE|welding|lack of weld|scm|scm|vendor|operator error|Defect on EC port|unknown info root_cause
Q3|7103233|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|electrical|modems communications|defect locations onshore|efat|initial direct product problem|function|SCM shows 'framing error' during EFAT|unknown info root_cause
Q3|100016110|01/05/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CVLP-5 was slow to open|unknown info root_cause
ZF|100018600|25/03/2011|priority 2 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOPT NOTE|other defect|part lost|scm sem el opt component|other scm sem el opt components|vendor|maintenance|Falha na Placa HCTB SEM B|MMR Activities
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte solonoider på ventiler.|unknown info root_cause
ZF|P6000105542|10/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN19|Wrong welding pin defined for man. block
ZD|P6000088751|22/02/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|damage|damage during testing|scm|scm|service :|damaged during installation|GWF SCM #3 DHI COMMUNICATION INSTABLE|COMMUNICATION INSTABLE
ZF|P6000079433|24/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm hyd mech components|other mechanical components|assy|operator error|Leakage from blind plate|O-ring damaged on blind plate
ZF|P7000024900|16/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|coating defect|scm hyd mech components|outer can|assy|damaged during assembly|Scratch inside of the Outer Can|101545 - KRISTIANSANDS SKRUEFABRIKK101545 - KRISTIANSANDS SKRUEFABRIKK
ZF|100049000|01/06/2010|priority 2 |Q3|BP|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|qa qs qi|documentation error|Shipped w/o QA approval|unknown info root_cause
ZD|P6000068912|30/07/2013|priority 2 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|marking|no marking|scm test stand|hydraulic couplers|intercompany|kongsberg|Missing Valve Cap P/N:100014108 from SCM|Missing Protection Cap
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000024900|15/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|test|incorrect set up testing|no communication with MRMS and CPU|Lab test box with problem.
ZE|P6000068918|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update MCM PSM - Luanda Workshop|Update is followed up in QN 200439169
ZF|P7000024900|04/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm hyd mech components|other hydraulic components|vendor|final inspection error|DAMAGE ON THE THREAD|115215 - TESS DRAMMEN AS  AVD. KONGSBERG
ZF|P7000039672|12/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|physical damage|scm hyd mech components|other hydraulic components|vendor|final inspection error|PLUG FOR FILTER DANIFICADO.|1242 HTS maskinteknikk as
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|100030542|30/03/2006|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|damage|unknown info damage_desc|scm|scm|vendor audit|unknown info cause_desc|FNCR RISED FOR CNR INTERNATIONAL|See QN200038889
ZF|P7000001843|19/04/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|Flow meter c/ leitura incorreta|Flow technology
Q3|7105128|28/03/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM P 02|unknown info root_cause
ZF|7105130|26/11/2006|priority 1 |Q3|TOTAL|unknown info region|ATCO NOCO NOPT NOTE|assembly test|missed operationassy test|scm|scm|other external causes|customer error responsibility|SCM outer can collapsed|used SCM when recommended to replace OC
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000068902|10/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|machining|burr chips|scm el opt components|other el opt components|vendor|specification not followed|Protector Cover for PT and valves|PT covers full of plastic burrs
ZF|P6000102554|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100020562|22/08/2009|priority 2 |Q1|BP|GOM|NOPT NOCO ATCO NOTE|test|function|scm electrical|i o pcbs|vendor|equipment malfunction|SEM A SIO board failure on Channel 0|SEM A SIO board failure on Channel 0
ZF|100052701|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|other defect|functional|fks quality system issues|quality management system|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|P6000105542|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|100017997|30/05/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|quality system issues|kos quality system issue|defect locations onshore (hes)|kongsberg a b|initial direct product problem|material|M8x55 A4-80  bolts used on COV|Module buildt before change of BOM
ZB|100048038|14/02/2009|priority 3 |Q1|AGBAMI|unknown info region|NOCO ATCO NOTE|other defect|functional|scm electrical|pressure transducers|other causes damage|damage from wear and tear|PT sensor for CIV-04 gives bad readings|unknown info root_cause
ZF|P7000000897|02/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|documentation|incorrect certificates records|scm|scm|qa qs qi|documentation error|Item não apresentado no Set Out|unknown info root_cause
ZF|P6000068902|06/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|100017305|01/10/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|electrical|sem powersupply|defect locations onshore (hes)|admin|root cause engineering|design specification error|AUX Clarification for SCM`s|Incompatible requirements in specificati
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|electrical|rcm electronics|defect locations onshore|montasje|initial direct product problem|material|Refurbishment  Bytte av Trykktransdusere|unknown info root_cause
ZF|3812476|14/05/2010|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|procedure process error|scm|scm|engineering|continuous improvement|Duplicate doc describing work process|No failure QN created to STD helium test
Q3|100018820|26/08/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|scm rcm|scm|defect locations onshore|fks adm.|root cause engineering|other product design error|SCM`s ARE BUILT FOR 230V INSTED FOR 450V|Design spec error - corrected
Q1|7104033|04/03/2003|priority 2 |Q1|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|hydraulic|hydraulic coupler|defect locations offshore field|borgland dolphin|root cause engineering|other product design error|SCM 06 Sygna N-2H poss. hyd lock 24/25|unknown info root_cause
ZF|P6000104115|16/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm|scm|assy|damaged during assembly|Water inside the SRM|O-ring on OC1 damaged follow-up200398887
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|NOTE NOPT ATCO NOCO|test|function|scm|scm|other causes damage|no noncompliance|Investigate Coupler Rotation-BPAT SCM 31|Investigate Coupler Rotation-BPAT SCM 31
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE NOCO|design|dbi error|scm hyd mech components|other mechanical components|engineering|dbi error|Wrong Bill Of Material and wrong parts|Wrong flowrestrictor used
ZF|P7000024191|10/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|test omitted|scm|scm|test|incorrect set up testing|Man. Global #18 Can Bus & Serial Line|Lab test box with problem.
ZF|P6000079032|07/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE|machining|slot error|scm hyd mech components|outer can|vendor|specification not followed|Drain holes for outercan not acc to dwg|Outercan not produced acc to DWG
ZF|P6000079433|02/02/2012|priority 2 |Q3|CONOCOPHILLIPS|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|other causes damage|no noncompliance|SCM S/N 01 PT's not working|No failure
ZF|P6000073687|14/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|APT4 not working|Pin 9 and 10 was switched on EC4
Q1|7101401|05/03/2002|priority unknown info priority|Q1|PETROBRAS|unknown info region|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|defect locations offshore field|campos basin|initial direct product problem|cleanliness|Choke control valve malfunction|Contamination in hyd system
Q3|100031193|16/04/2004|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTE NOCO ATCO NOPT|scm rcm|scm|ext. loc. kos houston|goods receipt|root cause qa qs|qa qs inspection error|Wrong SEM adress on marking plate|Plate not mounted on at the time of insp
Q3|7104033|10/05/2000|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|statfjord c|initial direct product problem|function|XT Annulus PTs  readings are fluctuating|Suspect moisture is causing offset
ZF|100052231|11/12/2006|priority 2 |Q3|CHEVRON|GOM|ATCO NOTE NOCO NOPT|assembly test|do not use|scm|sem|vendor|component error|Service order due to AI 150 issue|improvement of DC/DC converter quality
ZF|P6000103208|21/03/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|7103553|11/10/2017|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO|software|program configuration|computer system software|sw|other causes damage|qn cancelled|Correct communication frequenzy  SCM M02|Should have been ZE QN. ZE 200553194
ZF|100018600|16/02/2004|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO NOPT|assembly test|function|scm electrical|modem pcbs|assembly test|miscellaneous|FAIL WITH COMMUNICATION TO SEM A AND B|Bad wiring in test equipment.
ZF|100052701|04/11/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|documentation|missing certificates records|scm|scm|engineering|specification error|Batch no. missing in iBASE|Batch no missing on bolts in iBASE
ZF|100055762|02/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|missed operation|test and transportation|other scm test & transport equipment|test|missing parts|WGM simulator not available for MOB test|CPI WGM simualtor not available
ZF|100067526|28/11/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|drawing error|scm el opt components|el. connector|engineering|dwg error|DU600076575 - incorrect text EC3 and EC4|DWG updated  ECN 6174744
ZF|P6000069056|01/09/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|electronic boards|comm.link (power line)|other causes damage|qn cancelled|MRM topside on SPCTU|Failure outside SCM  (cable in SPCTU)
ZF|100041493|19/12/2006|priority 4 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|raw material|defects in material|scm|scm|other causes damage|unknown info cause_desc|All return pipings were rusted off|Wear and tear
ZF|100056443|16/03/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|test|function|scm sem el opt component|sem cable & wiring|other causes damage|cause not found|No respons from DH gauge at Troll O2 O23|unknown info root_cause
ZF|7104075|02/08/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|scm|scm|vendor|component error|Shell SCM 10 has 2 bad PT's|Shell SCM 10 has 2 bad PT's
ZD|100025661|13/02/2007|priority 2 |Q2|SHELL|GOM|NOCO ATCO NOTE NOPT|assembly test|function|scm|scm|vendor|material error|TRANSMITTER GIVEN BAD READINGS|BAD TRANSMITTER
Q3|7105597|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|product defects for dept.|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|EFAT performed before Inhouse test|unknown info root_cause
ZF|P6000126219|15/08/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|test|incorrect set up testing|Faultfinding - Megging of EC 2 ethernet|unwillingly IR tested wire 7 & 8
ZF|P7000024900|14/11/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|change deviation request|raw material substitution request|scm|scm|other causes damage|cause not found|SOLICITAÇÃO DE CONCESSÃO|unknown info root_cause
ZF|100035013|06/08/2008|priority 3 |Q3|SHELL|unknown info region|NOPT NOTE NOCO ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|missing earth on baseplate plug|unknown info root_cause
Q3|7104033|16/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|electrical|sem el.rack|defect locations onshore|montasje|initial direct product problem|damages|SEM B sitt power supply ødelagt|unknown info root_cause
Q3|7103479|03/10/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|product defects for dept.|scm|defect locations onshore|workshop other|root cause other|customercustomer error|Comms. failure (SCM returned) + upgraded|No Fault Found ref. REP-0012372
ZB|7102969|21/03/2007|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|assembly test|function|scm electrical|pressure transducers|other causes|qn cancelled|HP sensor not corresponding with externa|Closed as info only.
Q3|7102643|20/03/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM PT incorr.feed back reg.valve status|unknown info root_cause
ZF|100027228|02/06/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|service maintenance|unknown info damage_desc|software fks provided|etu|engineering|procedure error|MANGLET SIGN. PÅ FUNKSJONSLINJE|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTI NOCO NOPT|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Marlim SCM 03-ALFA to 03-GAMA|Wrong materials
ZB|7102643|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|other defect|functional|scm|scm|service :|improper job preparation|Warranty claim 221-Åsgard-SCM replacemen|unknown info root_cause
ZF|100020278|05/08/2005|priority 3 |Q3|EXXONMOBIL|unknown info region|NOPT NOTE ATCO NOCO|design|dbi error|scm|scm|engineering|engineering error|The El.Can screws are too short.|unknown info root_cause
Q3|3794920|09/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PT damaged during dis-assembly|unknown info root_cause
ZF|100056443|22/10/2009|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|test|component error|scm|scm|test|operator error|Sensor error|Pressure sensor is within requirment
ZF|P6000042968|09/12/2009|priority 3 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOTE NOPT|test|function|scm|scm|assy|operator error|deviation between tank and scm pressure|Hose Glued not Silicone bladder nippel
ZF|100018082|14/01/2013|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of test equipment
ZD|100048038|11/03/2008|priority 3 |Q2|CHEVRON|WEST AFRICA|ATCO NOTE NOCO NOPT|raw material|unapproved material subst|scm|scm|vendor|material error|Unapproved Material Used|Unapproved Material Used
ZF|7105128|10/11/2003|priority unknown info priority|Q3|TOTAL|unknown info region|NOCO NOTE NOPT ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic control valves|unknown info cause_group_desc|unknown info cause_desc|Refurbish SCM|Pending investigation
Q1|100006609|20/03/2003|priority 3 |Q1|PETROBRAS|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM 03 Ronc. slot 3/4 hyd.coupl. malfunc|unknown info root_cause
Q3|7104670|unknown info defect_date|priority 1 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|electrical|dhi interface|defect locations onshore|workshop|initial direct product problem|function|SCM problems w/ comm. to DH simulator|unknown info root_cause
ZF|P6000088604|12/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No failure detected in extended testing
ZB|100016711|06/01/2010|priority 2 |Q1|BP|GOM|ATCO NOCO NOTE|damage|damage during assembly|fks quality system issues|quality management system|assy|operator error|SCM 32 Silicone Relief Check Valve|Improper calibration
ZB|P6000083428|22/04/2015|priority 4 |Q1|unknown info customer_name|unknown info region|NOTI NOPR OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Knarr Claim 009 PT Manifold SCM SUBSEA|unknown info root_cause
ZF|P6000031350|18/11/2008|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|marking|no marking|scm|scm|assy|missing operation|Bolts not torque-marked|unknown info root_cause
Q3|3801623|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|electrical|sem el.rack|defect locations onshore|workshop other|initial direct product problem|function|"Feil målemotstand R4 / ""Flytte"" anode"|Fleire feilforhold
Q3|7102643|17/10/2000|priority 4 |Q3|STATOIL|NORTH SEA|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM upgrades after removal of outer can|unknown info root_cause
Q3|100020278|30/01/2003|priority 3 |Q3|EXXONMOBIL|unknown info region|NOPT NOCO ATCO NOTI|mechanical|outer can|defect locations onshore|tank test|root cause assembly test|other product design error|EC`s were assembled wrong in outercan.|SCM workshop assembly errorMisleading DWG
Q3|7103233|10/01/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|mechanical|hydraulic manifold block|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|Fresh water flowed through SCM HP return|XT valve opened by error when testing
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000016420|06/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|cleanliness|hydraulic products|compensator|vendor|specification not followed|Return compensator|cleanness - Quality Hidraulic power
ZF|P6000063531|27/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000121268|01/12/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|specification error|scm hyd mech components|check valve|engineering|engineering error|Check valve missing O-ring|O-ring not scope of supply
ZF|100048038|06/09/2006|priority 1 |Q3|CHEVRON|WEST AFRICA|NOPT ATCO NOCO NOTE|design|specification error|scm|scm|vendor|component error|Problem with AI151 cards|Bad workmanship
ZF|P7000024191|25/10/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOPT NOTE ATCO|damage|damage due to handling|scm hyd mech components|locking mechanism|assy|improper handling|MMR - Pin of Extension Rod Smashed|Handle of Lock Mech torqued
ZF|P7000001621|04/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|change deviation request|process substitution request|scm|scm|assy|operator error|QA não convocado|unknown info root_cause
ZF|100037428|16/08/2006|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|assembly test|function|scm|scm|engineering|engineering error|Rosa SCM Nr.7 failure|Weakness in Procedure   HFT-0000021176
ZF|100020278|21/03/2011|priority 3 |Q3|EXXONMOBIL|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|other causes damage|planning error|Re test SCM (RIT)|SCM used to test SS18 and Tree4/7.
Q3|100016901|15/01/2003|priority 3 |Q3|BP|GOM|NOCO ATCO NOPT NOTI|scm rcm|scm|ext. loc. kos houston|work shop|root cause engineering|other product design error|EC's on top of SCM installed wrong|Wrong DWG
ZB|P1000004979|17/01/2008|priority 2 |Q1|BP|unknown info region|NOPT NOCO NOTE|test|function|scm electrical|dhi pcbs|vendor|equipment malfunction|DH gauges fail to initialize|unknown info root_cause
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Not performed HFT do to lack of time|unknown info root_cause
ZE|P6000121958|30/12/2015|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|intercompany|kongsberg|SCM Wiring Does Not Match Field Wiring|SCM Wiring Does Not Match Field Wiring
ZF|100048038|26/06/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOCO ATCO NOPT|design|user documentation procedures|scm|scm|assy|operator error|Damage to EC13 and procedure problems|HFT Document ErrorsInspection of Test Stand Did not detect
ZF|7104075|04/12/2006|priority 3 |Q3|SHELL|GOM|ATCO NOPT NOCO NOTE|assembly test|function|scm|scm|vendor|component error|Out Of Range Index Readings on ETU|Index Readings Out Of Range On ETU
ZF|P6000055605|04/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|procedure error|scm|scm|engineering|engineering error|TST60053523 Software documents|Procedure TST60053523 has been updated
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOTE NOPT ATCO NOCO|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100037427|09/11/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|physical|scm|scm|materials stores|operator error|Wrong S/N on outercan|Wrong S\N in ibase list
ZF|100048038|04/10/2006|priority 2 |Q3|AGBAMI|unknown info region|NOPT NOCO NOTE ATCO|design|do not use|scm|sem|engineering|dwg error|AI 151 card has to be updated|Problem with software AI 151 card
ZF|7104075|23/08/2005|priority 3 |Q3|SHELL|GOM|NOCO NOPT NOTE|assembly test|do not use|scm|hydraulic valves|other causes|do not use|Choke DCV shows different PN than DBI|Poor valve P/N documentation from Housto
ZF|7101401|25/06/2004|priority 2 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|machining|length error|scm mech w mb|locking mechanisms|engineering|design specification drawing error|Marlim SCM Extension Rod|Length changed by mistake
Q3|7105597|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|product defects for dept.|scm|defect locations onshore|workshop|initial direct product problem|function|SCM controlmodule|Leak at stab connector.
ZF|100052231|28/10/2010|priority 2 |Q3|CHEVRON|GOM|NOCO ATCO NOPT NOTE|test|component error|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|other causes damage|damage during transport|Bad SIO board readings on SEM A|Bad SIO board readings on SEM A
ZF|P7000000897|04/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage during assembly|electric products|electrical connector|assy|operator error|EC8 with HW525 inside the hose.|HW525 inside the yellow hose
ZF|P6000042968|02/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly|assembled incorrectly|hydraulic products|coupler|assy|damaged during assembly|Change hydraulic coupler|Sharp edge on Male coupler   test equip.
ZF|P6000121393|02/10/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (fluid)|hydraulic products|coupler|vendor|equipment malfunction|HC1 LEAKING|Hydraulic coupler leakage
ZF|P6000064909|20/03/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|Change of Hydraulic Fluid in Laggan-Torm|Hydraulic Fluid change in procedure.
ZF|P7000000897|24/06/2015|priority 1 |Q3|SHELL|unknown info region|ATCO NOCO NOTE|assembly|physical damage|scm hyd mech components|outer can|assy|damaged during assembly|MMR - Spacer's Thread of Outer Can|unknown info root_cause
ZF|P6000068770|07/07/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|imension (tolerance)|scm hyd mech components|outer can|vendor|specification not followed|Bracket in outercan conflict|Bracket conflict inside outercan
ZF|P6000062990|20/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|leakage (fluid)|scm|scm|vendor|specification not followed|Water in silicone oil|Paint on sealing surface caused leakage
Q3|7104033|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|mechanical|outer can|defect locations onshore|fat|initial direct product problem|documentation|Test av ytterkanne mangler i TPR.|unknown info root_cause
Q3|7104033|10/05/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|electrical|modems communications|defect locations offshore field|statfjord c|initial direct product problem|function|Comms. with wells G3H and G4H not stable|Comms transmission frequency/changed
ZF|100030711|28/02/2006|priority 3 |Q3|STATOIL|unknown info region|NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM failure|unknown info root_cause
ZF|P6000109194|10/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100037966|26/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|SCM P26  HFT  voltage clarification|Typo in procedure.
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|product defects for dept.|scm|defect locations onshore|workshop other|problem causes defect causes|design|SHE DIV|unknown info root_cause
ZF|P6000057855|11/02/2010|priority 3 |Q3|ENI|unknown info region|ATCO NOCO NOPT NOTE|test|function|electronic boards|other eletronic boards|test|damaged during testing|Communication failure SEM|Error to be confirmed in QN200153739
ZF|P6000055605|03/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|drawing error|scm|scm|engineering|dwg error|Wrong information on the drawing|Wrong temperature on GA DWG(nameplate)
ZF|7104075|10/02/2006|priority 3 |Q3|SHELL|GOM|NOTE ATCO NOCO NOPT|design|user documentation procedures|scm|scm|other causes|no noncompliance|FAILURE TO OPPERATE TO PRD REQUIREMENTS|PART ACCEPTED-NO NON-COMPLIANCE
Q1|7102643|12/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|electrical|pressure transducer|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 17 ÅSG.A S-2H PT Func XOV/AMV malfun|unknown info root_cause
ZB|P6000088614|02/12/2015|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|interface issue|scm|scm|assy|operator error|Shah Deniz Test Connector and SCM 05|Used faulty test connector
ZF|P6000083428|09/01/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000147469|21/11/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|coating plating|painting defect|object types to eng matl class|scm_assy|vendor|coating defect|QUALITY ISSUE|unknown info root_cause
ZF|P6000074156|16/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|assy|lack of training|HPDCV 54 failure - SCM 402|HPDCV 54 failure
ZF|P6000039844|22/09/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|instrumentation|other scm instruments|engineering|procedure error|Incorrect prosedure|Procedure Error  SPC was wrong
ZF|100035013|15/02/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|documentation|incorrect user documentation (customer)|fks quality system issues|quality management system|engineering|unknown info cause_desc|Gammel software|Update of procedure
ZF|7103233|15/06/2005|priority unknown info priority|Q3|SUNCOR|unknown info region|NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|other causes|do not use|SIO failure ?|Not known.
Q1|7102643|23/05/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|product defects for dept.|scm (mech) valves|defect locations offshore field|transocean searcher|initial direct product problem|leakage|Åsg 10  internal leak of hydraulic fluid|PT defective ref. QN 200003254
Q3|100018082|11/11/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|Blind plug hit mounting base|Plug must be mountet from inside.
ZB|P6000039844|28/09/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI OSNO OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Shell GK_ Missed PSM for SCM 25|unknown info root_cause
ZF|P6000064909|15/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|component traceabilitynot maintained|scm el opt components|scm wiring|assy|operator error|Wiring falure on COVHP and COVLP|Marked wrong during assembly.
ZF|P6000063531|23/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|hydraulic fittings|assy|missing operation|Leakage in butech fitting|Not tightened after connection to comp
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|electronic boards|other sem (non standard)|projects|material error|CAR2 Implement RCA Actions_1 RPT10033107|unknown info root_cause
ZF|100035013|06/02/2008|priority 3 |Q3|SHELL|unknown info region|NOPT NOCO NOTE|documentation|missing certificates records|scm|scm|other causes|no noncompliance|missing batch numbers|unknown info root_cause
ZF|P6000029747|09/12/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|machining|outside diameter error|scm|scm|other causes damage|qn cancelled|Protection ring still with thick weld|Protection ring can be used as is.
ZD|P6000147859|12/03/2018|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE|marking|no marking|scm|scm|engineering|dbi error|Marking Issue|Rev marking not specified
ZF|P6000100953|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100001156|08/03/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|ss compl. & w.over xt r. tools|xmas tree running tool for cxt|vendor|material error|10 L-4H GFC AI card SEMA malfunct.|Failure in AI Card batch
ZF|P6000064911|02/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|other defect|functional|electronic boards|other eletronic boards|other causes damage|qn cancelled|No communication fiber line 2|No error
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|ATCO NOTE NOCO NOPT|assembly test|function|scm|scm|other causes|no noncompliance|VALUES NOT UPDATING AT SPECIFIED TIME|Setting in Top Side SW incorrect
Q3|7102643|04/10/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|documentation|No procedure for IR testing of PT's|PRD-000020064 released 26.10.00
ZF|P7000024900|30/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|other defect|physical|scm|scm|other causes damage|no noncompliance|CONCESSION REQUEST|unknown info root_cause
ZF|100038200|02/06/2005|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|assy|missing operation|SCM 63 NOVA DH procedure|Failure during RIT test procedures
ZB|100018600|04/05/2004|priority 3 |Q1|PETROBRAS|unknown info region|ATCO NOTE NOCO|assembly test|handling damage|scm mech w mb|other scm mechanical|assembly test|assembly test error|Vacum pipe SCM#2 not according to design|Tube was not proper fixed/replaced.
ZF|P6000068902|01/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Pressure on PT 11 when opening CVLP 7|Operator error  new personnel
ZF|7103233|09/09/2014|priority 2 |Q3|FRAME AGREEMENT TERRA NOVA|unknown info region|NOTE ATCO NOCO NOPT|assembly|assembled incorrectly|scm|scm|vendor|specification not followed|Water inside SCM after hyperbaric test.|Bad cleanliness caused water ingress
ZF|P7000024900|16/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|component traceabilitynot maintained|scm hyd mech components|check valve|other causes damage|cause not found|BC10/39 - Check Valve Tipagem errada.|ECN não implementada
ZF|P7000001621|20/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|vendor|maintenance|COVHP com Vazamento Hérc Ug.15|SCM MMR
ZF|100029149|11/03/2004|priority 4 |Q3|TOTAL|WEST AFRICA|NOPT ATCO NOCO NOTE|assembly test|workmanship general|scm electrical|wiring|assembly test|assembly test error|Problems with DHI during Hyperbaric|Wiring personell used wrong Rev.
ZF|100037965|11/01/2011|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|function|electronic boards|main boards cpu & i o|vendor|clarification|Investigation BP SCM Failures|Ref QNR text
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|hydraulic|hydraulic control valves|defect locations offshore field|shell alliance gom|root cause other|customercustomer error|SCM is venting control fluid offshore|Worn seat in CV due to customer mat.reqm
Q3|7103233|19/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|function|Install hydaulic flow restrictors|unknown info root_cause
Q3|7102643|13/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations onshore|workshop|initial direct product problem|cleanliness|SCM not cleaned prot.and preserv.missing|unknown info root_cause
ZF|P7000039672|18/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm hyd mech components|other hydraulic components|vendor|specification not followed|Interferência Plug f/filter Linha F2- LP|unknown info root_cause
ZF|100037428|08/04/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|damage|wear & tear|scm|scm|other causes damage|damage from wear and tear|Worn out threads|Wear
ZF|P6000083428|10/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|change deviation request|part substitution request|scm hyd mech components|hydraulic coupler|engineering|specification error|HC72 to be replaced with blind coupler|BOM needs update. Wrong PN on HC72
ZF|P6000121268|27/03/2015|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|physical damage|scm el opt components|el. connector|test|damaged during testing|(CDM)SCM EC6 Damage - ENI Jangkrik|Electrical connector damage
ZF|P6000076121|20/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|No communication with MPFM|Wiring fault. Human error
ZF|P7000016420|27/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm hyd mech components|locking mechanism|qa qs qi|goods receiving inspection error|Revestimento da bucha em desacordo|REVESTIMENTO
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|hydraulic|hydraulic control valves|defect locations offshore field|shell alliance gom|root cause vendor|material component error|Choke Valve failure|Wear in pilot stage.
ZB|100001156|02/06/2004|priority 4 |Q1|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|assembly test|miscellaneous|scm hydraulic|hydraulic couplers|other external causes|customer error responsibility|SCM delivered with blind plugs|unknown info root_cause
Q3|100009059|07/02/2001|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|scm rcm|scm|ext. loc. kos houston|work shop|root cause other|logisticspacking shipping damage|SCM damaged by shipping company|unknown info root_cause
Q3|7104670|08/11/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations onshore|fks adm.|root cause engineering|test procedure error|Hook-up & Function Test|unknown info root_cause
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
Q2|7100320|03/11/1999|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|product defects for dept.|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|function|Oppgrader Hercules 09|unknown info root_cause
ZF|P6000069056|28/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring ERROR EC3  EC4 and EC5 O.C.T|Opr. failure during SCM wiring
ZF|100056443|23/02/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|NOPT NOCO ATCO NOTE|design|specification error|scm|sem|engineering|engineering error|Addition of Grounding Power-can|Design improvement for safety precaution
ZD|7104075|18/12/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|damage|damage from corrosion|scm hyd mech components|outer can|vendor|packaging handling|Crrosion on ECs|unknown info root_cause
ZD|P6000028371|14/08/2012|priority 2 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|procedure error|common misc general|software|engineering|procedure error|SEM Software Defect|SEM Software Defect
ZF|100017305|10/10/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|software|component failure|scm|scm|other external causes|customer error responsibility|CR Fram Vest FD012 SCM|Customer take responsibility for deviati
ZF|7105597|19/10/2010|priority 2 |Q3|PETRO SA  MOSSEL BAY|unknown info region|NOTE NOCO|documentation|procedure process error|scm|scm|projects|documentation error|Material not delivered to plant|unknown info root_cause
ZF|P7000001621|02/08/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|machining|angle error|scm|scm|machine shop personnel|operator error|Fechamento da outer can|Usinagem realizado em defasagem
Q3|7100320|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Skifte solenoider Hercules sn-13|unknown info root_cause
ZB|100001156|13/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|raw material|defects in material|scm|scm|materials stores|operator error|SCM 7 GFA Rimfaks J-4H HP Hyd. leak.|Bolt failure on blind plate
Q3|7101172|25/10/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM upgrades after removal of outer can|unknown info root_cause
ZF|100026567|25/06/2003|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|pressure intensifier|vendor|material error|Leak in SCM HPI on production XT|Ref. QN 200015669
Q1|100018082|29/10/2002|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|hydraulic wocs ics equipment|workover control panel (wocs)|defect locations offshore field|transocean searcher|initial direct product problem|function|Mikkel SCM/WOCS SW interface mismatch|unknown info root_cause
Q3|7102643|20/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|leakage|SCM on J3-H  Hyd leakage in HP system|2 bolts on control valve broken
ZF|P6000068924|20/06/2012|priority 3 |Q3|TOTAL|unknown info region|NOTE NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|ground straps found with poor crimp|Poor wire-crimps on ground straps
Q3|100025735|13/02/2003|priority unknown info priority|Q3|OVERALL PROJECT ROLL-UP SKIRNE / BYGGVEWELL NO C-1H|unknown info region|NOTE NOPT NOCO ATCO|mechanical|outer can|defect locations onshore|workshop other|root cause engineering|design specification error|Guidepins on top of Outer Can SCM#1|unknown info root_cause
ZB|100055600|27/10/2008|priority 2 |Q1|TALOS|GOM|NOCO NOPT NOTE|test|leakage (fluid)|scm hydraulic|other scm hydraulic|other causes damage|cause not found|SCM #96 has a hydraulic leak subsea.|SCM #96 has a hydraulic leak subsea
ZF|P7000016420|15/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|Minimum flow failure|Flow technology
Q3|7104033|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|Tests missing after mounting of Outercan|KOS documentation error
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte av solonoider på ventiler.|unknown info root_cause
ZF|100030542|29/01/2008|priority 3 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOPT NOCO NOTE|documentation|missing certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|Change: batch cert. to batch management
Q3|100015314|09/10/2001|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|product not qualified|Hydraulic assy mod: bypass valve/filter|Improvements to meet NH cleanliness spec
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Missing rubber prot.inside comp. chamber|unknown info root_cause
ZE|100035013|10/06/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Flow direction wrong on drawing|unknown info root_cause
ZF|P7000039672|14/01/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|other defect|part lost|scm el opt components|el. connector|vendor|missing parts|Conector pago sem mangueira|unknown info root_cause
Q1|7104033|28/02/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOTI ATCO NOPT NOCO|electrical|sem el.rack|defect locations offshore field|statfjord c|initial direct product problem|function|SCM 2 SF Nordfl. SEMA A/I card malfunct.|unknown info root_cause
ZE|P6000088751|26/02/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|documentation|procedure process error|scm|scm|service :|lack of training|WEL PSM not followed(NA)|unknown info root_cause
ZB|P6000105710|01/09/2016|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|software|other specify in comments|electric products|other electric products|software|other specify in comments|Julia IWCS lack of comms|See above.
ZF|P6000104112|08/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000104116|23/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|O-ring sealing surface fault|O-ring surface not according to DWG
ZF|P6000121268|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZE|7102643|01/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|topside products|n a sw|accepted &|accepted|DHI 109 config file|unknown info root_cause
ZE|P6000147469|05/03/2018|priority 1 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CNOOC Wenchang  EHXT  PT Sensor Issue|unknown info root_cause
ZD|100016711|22/01/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|electric products|electrical connector|vendor|equipment malfunction|EC Loss of Connectivity|unknown info root_cause
ZF|7104075|22/07/2005|priority 3 |Q3|SHELL|GOM|NOTE NOPT NOCO ATCO|assembly test|function|scm|scm|vendor|component error|INTERNAL PT OUT OF RANGE|INTERNAL PT OUT OF RANGE
ZF|100056443|26/10/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|NOCO NOTE|raw material|dimensional|scm|sem|other causes damage|cause not found|Wrong Clock frequency|unknown info root_cause
Q3|7100320|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOCO NOTI|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM 01|Wrong materials
ZF|P6000093501|21/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|specification error|computer system software|etu sw|engineering|engineering error|Smart return PT missing in signatur|unknown info root_cause
ZF|P6000083395|15/03/2012|priority 3 |Q3|TOTAL|unknown info region|NOTE NOPT NOCO ATCO|documentation|procedure process error|scm|scm|other causes damage|qn cancelled|Fault in sensor schematics|Not relevant QN.
ZE|P6000093498|20/10/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|electronic boards|eth.net items|electrical|other specify in comments|LLP WOCM unable to communicate with WCP|Equipment damaged by lightnig
ZF|7102969|13/07/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly test|do not use|scm|scm|vendor|component error|Pressure readings with 0 bar supply|Pressure readings with 0 bar supply
ZF|P6000074156|30/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|other causes damage|cause not found|DHI 204 SEM B error in report log|Incident described  SCM is fully working
Q3|7104020|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|scm rcm|scm|defect locations onshore|tank test|initial direct product problem|documentation|TPR-0011028  Factory Acceptance Test.|unknown info root_cause
Q3|7100320|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOPT NOTI ATCO NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Hercules SCM 08|Wrong material
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|Waiver hyperbaric test on SCMs 2 & 3|Waiver tank test after re-opening
ZF|P7000000897|10/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|assembled incorrectly|scm hyd mech components|hydraulic fittings|assy|operator error|Damaged part during assembly|Montagem incorreta danificando peça
ZB|100049000|19/01/2007|priority 2 |Q1|BP|unknown info region|NOCO NOTE NOPT|assembly test|function|scm electrical|pressure transducers|vendor|test error|Press transducer reading 2000PSI high.|unknown info root_cause
Q3|7104670|15/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations offshore field|heidrun tlp|initial direct product problem|function|XT / SCM / TH|unknown info root_cause
ZB|100035400|08/05/2007|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOTE NOCO|damage|unknown info damage_desc|scm hydraulic|compensators|vendor|equipment malfunction|SCM compensation Bladder leaking|SCM compensation Bladder leaking
ZD|100016901|06/09/2013|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE|coating plating|incorrect colour coating|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|vendor|specification not followed|Incorrect coating (B)|unknown info root_cause
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Shell SCM Loss of Hydraulic fluid|unknown info root_cause
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|ATCO NOCO NOTE|change deviation request|conversion approval|scm|scm|intercompany|kongsberg|SCM Change Hydraulic Fluid|SCM shipped to be reflushed
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|function|GFS SCM 05  Bytting av solenoider|unknown info root_cause
ZF|P6000116360|10/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|machining|length depth error|scm|scm|other causes damage|cause not found|EC3 is loose.|Holes re-threaded  no investigation
ZF|P7000001621|18/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|imension (tolerance)|scm|scm|other causes damage|cause not found|Problemas com rosca interna|unknown info root_cause
ZF|P6000101955|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100016711|04/08/2011|priority 2 |Q3|BP|GOM|NOCO ATCO NOTE|damage|damage from corrosion|electric products|electrical connector|other causes damage|damage from wear and tear|EC conectors pitted/corroded.|EC connectors pitted / corroded
ZF|P7000000897|25/09/2018|priority 3 |Q3|SHELL|unknown info region|NOCO ATCO NOTE|assembly|assembled incorrectly|object types to eng matl class|scm|assy|operator error|MMR - Failure During DCV 23 open SEM B|unknown info root_cause
ZF|100026567|18/05/2004|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|THE SCM IS LEAK|unknown info root_cause
ZE|P6000062454|29/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Sofware version upgrade|Software version upgrade.
ZF|P6000104114|31/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|vendor|clarification|AI reading from PSDM outside criteria|Magnetic SEM canister
ZB|7102643|15/11/2008|priority 4 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|other defect|physical|scm|scm|vendor|operator error|F&D Over torque on SCM|Incorrect op. of the 2700 Nm torque tool
ZF|100058509|23/02/2011|priority 3 |Q3|LLOG|GOM|ATCO NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|other causes damage|no noncompliance|Missing documents & sign offs|missing documents & sign offs
ZF|P6000055605|08/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|LP return flowmeter low flow failure|See ZD QN 200392890
ZF|P7000001621|06/03/2018|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|damage|damage during assembly|object types to eng matl class|scm_components|assy|damaged during assembly|MMR - Compensator Bladder Leakage|unknown info root_cause
ZE|100035119|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Enfield - SCM Issue|SCM Issue
ZF|100020278|25/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|machining|length depth error|scm|scm|vendor|specification not followed|cylindricalpin bunner mot blokk og plate|Guide pin too long
ZF|3812476|16/07/2008|priority 4 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|documentation|missing user documentation (customer)|scm|scm|other causes damage|planning error|Not full information regarding SCM 07|SEM address not ready prior to offshore
ZD|100035118|06/12/2007|priority 1 |Q2|PETRONAS|unknown info region|NOTE ATCO NOCO NOPT|documentation|missing certificates records|scm|scm|other causes damage|planning error|Missing Documentation|Failure to Make Instructions clear.
ZB|7101172|16/03/2006|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOCO NOPT|assembly test|function|scm|scm|other causes|do not use|SCM 10 GFA  I-4H SEMA com.failure|Unknown reason for failure
Q3|100015538|05/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations onshore|fks adm.|root cause engineering|material fault|SCM 9 NORNE upgrade DHI107/LP-Accu.|unknown info root_cause
Q3|7105128|25/05/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|mechanical|scm mounting base|defect locations onshore|efat|initial direct product problem|damages|SCM P 04|Connectors incorrectly installed on SCMB
ZE|P6000126219|21/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|adjust silicon compensator volume|Part updated
ZF|P7000000229|06/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|change deviation request|conversion approval|scm|scm|other causes damage|no noncompliance|Concessão de fluido  SCM #21 FRADE|Concessão para utilização de fluído
ZF|100048038|10/05/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|ATCO NOCO NOTE NOPT|assembly test|function|scm|scm|vendor|assembly error|Leak Detector fails during Hyperbaric|Decision made by Client
Q3|100018600|06/02/2003|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Upgrade of C-can.|unknown info root_cause
ZF|P7000008275|10/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|coating plating|incorrect colour coating|scm|scm|vendor|specification not followed|Teste de vacuo da outer can|Outer can test
ZF|100025661|27/04/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|drawing error|scm|scm|manufacturing|do not use|Difference in marking on drawings|letter size difference
Q3|7104670|08/11/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM upgrades after removal of outer can|unknown info root_cause
Q1|7102643|unknown info defect_date|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|scm rcm|scm|defect locations onshore|goods receipt inspection|initial direct product problem|documentation|Documentation - SCM missing punch list|Uklare retningslinjer
ZB|100020278|03/12/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE|other defect|functional|scm electrical|other pcbs|other causes damage|cause not found|08-MEGI-020: AIB Voltage Reference Error|08-MEGI-020: AIB Voltage Reference Error
ZF|P6000104111|18/01/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|wrong test procedure used|scm|scm|other causes damage|cause not found|SCMs Fliud Issue for PXT|unknown info root_cause
ZF|P7000001621|23/07/2015|priority 2 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|assy|missing parts|MMR - HW Leakage during In-House|unknown info root_cause
ZB|P6000042969|24/09/2010|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 13|Software improvement/correction
ZF|100064910|11/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|engineering error|Wrong bolts in BOM for SEM el-can.|Wrong screw P/N is listed in BOM
ZF|P6000104115|03/07/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|part lost|scm el opt components|el. connector|vendor|missing parts|Missing parts on EC-assy|EC assy not compleate follow-up200386426
ZB|100037428|04/05/2011|priority 4 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|machining|position error|stage gate review|customer support logistics plan|materials stores|improper handling|110402 - GIRRI_TOTAL_SONILS_WOR memo|unknown info root_cause
ZF|100035013|05/06/2008|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO NOPT|documentation|missing certificates records|fks quality system issues|quality management system|materials stores|unknown info cause_desc|Batch numbers missing|Diffrent batcnumber on screws
Q3|7102643|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Acceptance criteria flow in CIDV on SCM|unknown info root_cause
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOPT NOCO|electrical|pressure transducer|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 03 ÅsgB Y-3H PT LP Supply malfunct.|unknown info root_cause
ZF|140-141-004|03/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|test|damaged during testing|Vazamento da Câmara Hiperbárica|Vazamento no Jumper el. Durante Hiperb
Q1|7101172|05/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTI NOPT|electrical|modems communications|defect locations offshore field|deepsea trym|initial direct product problem|function|SCM 12 GFA J-5H Comm. problems SEMA|unknown info root_cause
Q2|7102969|unknown info defect_date|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|mechanical|outer can|defect locations onshore|montasje|initial direct product problem|material|Ytterkanne har maling flakket av.|unknown info root_cause
ZF|P6000116166|25/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|design|specification error|computer system software|scu sw|engineering|engineering error|Unstabile communication Tullow Ten|unknown info root_cause
ZB|P6000080678|12/01/2017|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|documentation requirement|procedure process error|object types to eng matl class|scm|qa qs qi|documentation error|WEL  SCM  Cleanliness procedure|unknown info root_cause
ZF|100018082|21/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|test|function|scm|scm|test|damaged during testing|Burned components in SEM B|FMC Test: Damaged during testing
ZF|P6000050867|23/03/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|component error|scm|scm|vendor|programmer error|SW Error|Programmer Error
Q1|100018532|26/08/2002|priority 3 |Q1|SHELL|unknown info region|NOCO NOPT NOTI|electrical sensor equipment|pressure temperature transmitters|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|function|SCM 1 Bijup.&Salema PT IMV. malfunction|unknown info root_cause
ZB|P6000031350|12/08/2008|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|unknown info damage_desc|customer compliant|noncompliance to customer requirement|other causes damage|unknown info cause_desc|Remaining b-punches at receival  Bergen|unknown info root_cause
ZF|P6000083428|10/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|change deviation request|part substitution request|scm hyd mech components|hydraulic coupler|engineering|continuous improvement|HC72 to be replaced with blind coupler|Replacement of PN in mech&SCM w\o BOM
ZD|P6000042969|13/05/2009|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|function|scm|sem|vendor|unknown info cause_desc|Cards fails to read gauges|New DHI interfaces & behaviour
ZF|P7000024900|18/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm hyd mech components|baseplate|other causes damage|cause not found|Não conformidade na rosca da base plate|Não conformidade na rosca da base plate
ZF|100020562|19/08/2010|priority 1 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|test|leakage (fluid)|scm|scm|test|damaged during testing|Damaged Part.|Cause not Found- RCA  in process
ZB|3812476|22/11/2006|priority 1 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|damage|damage from corrosion|scm|scm|other causes damage|unknown info cause_desc|Damaged exhaust lines on SCM # 12 Norne|Pipes corroded
ZF|7102969|09/05/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|wear & tear|scm|scm|vendor|component error|Broken bolt|Component failure
ZF|100048038|19/02/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT ATCO NOCO|assembly test|missed operationassy test|scm|scm|engineering|engineering error|PROCEDURE REVISION|PROCEDURE ERROR
ZF|P7000001621|01/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|scm|scm|assy|damaged during assembly|Substitução do PT di Hércules #11|Degradação ( PT Antigo)
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZD|100034440|10/09/2005|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|do not use|scm|scm|vendor|fabrication error|Missing Documentation|Documents errors
ZF|P6000069056|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|design|drawing error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Insufficient wall thickness in m. block|Ref. QN 200241870
ZF|P7000001843|14/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|assembled incorrectly|scm|scm|assy|damaged during assembly|Parafuso quebrado|unknown info root_cause
ZF|100034440|30/11/2010|priority 2 |Q3|HOUSTON STOCKING MK IV|unknown info region|ATCO NOCO NOTE NOPT|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P6000068912|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|7100320|13/04/2004|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE NOPT|assembly test|function|scm electrical|i o pcbs|other causes|miscellaneous|SCM Herc. 19 DO-150  card failure|Part is not available for investigation.
ZF|100037966|20/01/2009|priority 1 |Q3|BP|unknown info region|NOCO NOTE|damage|damage during testing|scm|scm|test|operator error|B18 SCM  - SEM A communication problems|unknown info root_cause
ZF|100052231|28/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|part substitution request|scm|scm|engineering|continuous improvement|Changing AI150 cards in both sems|AI-board design upgrade (U9  ADC150)
ZF|P7000000897|11/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Adapter plate apresenta avarias|unknown info root_cause
ZF|P6000065886|11/03/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|interface issue|scm hyd mech components|outer can|engineering|engineering error|assemble the Outer can to the module|Vacume pipe in module positioned wrong
Q3|3794920|13/11/2000|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM was stuck in Transportation Skid|Dirt and rust?
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte av solonoider på ventiler.|unknown info root_cause
ZF|P6000042969|28/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|other defect|part lost|scm hyd mech components|outer can|intercompany|dunfermline|Missing pins|Gone missing during transport
ZE|7104033|05/11/2018|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|marking|marking content error|scm|scm|marking|missing marking|GC 187201 wrong tag/use of procedure|unknown info root_cause
ZF|P7000000897|06/10/2017|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO|coating plating|coating defect|scm hyd mech components|baseplate|paintshop|operator error|MMR - Base Plate With Coating Damage|Failure During Transport
ZB|P6000042969|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE ATCO NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 14|Software improvement/correction
ZF|P7000039672|17/07/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|electrical|component failure|object types to eng matl class|scm|intercompany|kongsberg|SEM A did not communicate|unknown info root_cause
ZF|P6000039844|16/02/2011|priority 1 |Q3|SHELL|unknown info region|NOPT NOCO NOTE|other defect|functional|topside products|n a smart tool|other causes damage|cause not found|(SS)Found old software|unknown info root_cause
Q1|100020278|14/01/2003|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|electrical|sem powersupply|defect locations onshore|montasje|administrative causes|qsystem procedures not adhered to|SCM test equipent not calibrated|Workshop using un-calibrated equipment
ZF|100037427|28/08/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly test|function|scm|scm mounting base (scm|other causes|no noncompliance|Lack of protection Cap SCM MB|No error
ZF|7104075|02/02/2011|priority 2 |Q3|SHELL|GOM|ATCO NOCO NOPT NOTE|documentation|incorrect certificates records|scm|scm|qa qs qi|documentation error|Missing Sign offs|missed sign offs
ZF|P6000121268|12/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|procurement|incomplete kit of parts|instrumentation|scm pressure transmitter|vendor|specification not followed|Missing support ring & O-ring|Investigation in QN 200446598
ZF|P6000150910|11/09/2018|priority 3 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Part is not as specification|unknown info root_cause
ZB|P6000133916|03/08/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPR OSTS NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Moho IRCD Communication with SEM615|unknown info root_cause
ZF|100037965|11/03/2009|priority 1 |Q3|BP|unknown info region|NOTE NOCO|other defect|functional|scm|scm|other causes damage|cause not found|SIO board failure for DHG 109 SEM A|I/O board failed
Q1|7103234|23/04/2002|priority 3 |Q1|SUNCOR CPI|unknown info region|ATCO NOPT NOCO NOTI|electrical|pressure transducer|defect locations offshore field|fpso terra nova|initial direct product problem|function|SCM MIV function line PT malfunctioning|Suspect internal electronic fault in PT
ZF|P6000037365|26/08/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|other defect|physical|scm|scm|test|incorrect set up testing|Wrong Hydraulic Fluid Used During FAT|Wrong Hydraulic Fluid Used During FAT
ZF|100026567|05/05/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Vigdis OH-01 overhaul SCM # 4|Sensor simulator has been modified
ZF|7103233|13/10/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|EC`s in baseplate not grounded.|Ground wires not mounted
ZF|100037967|16/02/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|damage|wear & tear|scm hyd mech components|outer can|service :|damaged during installation|Concession raised to accept SCM M9|wear and tear
Q3|7104033|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|urenheter etter systemtest|unknown info root_cause
ZD|P6000080678|26/07/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|functional|scm|scm|vendor|incorrect set up|Modbus Slave ID Mismatch for WGM|Modbus Slave ID Mismatch for WGM
ZF|P6000028371|27/09/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly test|assembled incorrectly|scm|scm|assy|operator error|SCM wired according to wrong revision|wired with previous rev
ZF|100051269|27/09/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTE|design|drawing error|scm|scm|engineering|engineering error|Assembly  Workshop error|drawing error
ZF|7104075|06/06/2006|priority 3 |Q3|SHELL|GOM|NOPT NOCO NOTE ATCO|assembly test|function|scm|scm|vendor|component error|INTERNAL PT FAIL IR TEST|INTERNAL PT FAIL IR TEST
ZB|7100320|23/05/2003|priority 3 |Q1|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|assembly test|material faulty|scm electrical|other pcbs|vendor|material error|SCM 9 Hercules AIDO failure SEM A/B|unknown info root_cause
ZF|P6000043122|28/09/2009|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO NOPT|assembly|unknown info damage_desc|electronic boards|other eletronic boards|vendor|unknown info cause_desc|Wrong P/N on ESRS card?|Missing or insufficient marking
ZF|P1000018406|30/01/2009|priority 2 |Q3|BP|GOM|NOTE ATCO NOPT NOCO|machining|inside diameter error|hydraulic couplers|hydraulic coupler|other causes damage|no noncompliance|BP Thunder Horse DFCM|No Non-compliance-Use As Is
ZF|P6000060453|05/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|test|component error|topside products|n a sw|test|incorrect set up testing|No response from FSM|Problems with the Com port on the ETU PC
ZF|100033987|04/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage from corrosion|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|unknown info root_cause
ZF|P7000039672|10/12/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|interface issue|scm hyd mech components|sem bracket|materials stores|improper packaging & storage|SEM Bracket oxidada.|unknown info root_cause
ZD|P6000042308|19/09/2009|priority 3 |Q2|TULLOW|WEST AFRICA|NOPT NOCO NOTE ATCO|documentation|unknown info damage_desc|sensors|scm pressure transmitter (pt)|vendor|unknown info cause_desc|COC HAS INCORRECT SERIAL #|C OF C HAS WRONG SERIAL #.
ZF|100055762|15/06/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|marking|marking content error|scm|scm|other causes damage|no noncompliance|B&B Missing SEM adr marking on sign|Old generation marking plates
Q3|7101172|26/04/2000|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|electrical|sem el.rack|defect locations offshore field|gullfaks a|initial direct product problem|function|No temperature reading on SEMB  well K4H|-5V Power Supply on SEMB
ZF|P6000104111|25/01/2019|priority 4 |Q3|TOTAL|unknown info region|OSTS NOPT OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Plan Loadout of P18 SCM without full Mob|unknown info root_cause
Q1|7102643|16/07/2002|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 35 ÅsgA R1-H PT HP Supp. malfunction|unknown info root_cause
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 10|Software improvement/correction
ZF|100027228|04/06/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|FAIL WIYH CPU SOFTWARE|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Utskifting sn 07|unknown info root_cause
ZF|P6000083428|16/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|unknown info root_cause
Q3|7100320|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 04|unknown info root_cause
Q3|7104670|unknown info defect_date|priority 1 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|product defects for dept.|scm (el) electronic card|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|LVDT1 readings are too low when testing|AICF card failure  wrong test equip used
ZF|P7000000897|24/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|component error|scm sem el opt component|sem cable & wiring|intercompany|kongsberg|BC10-36 Fio solto no conector SIOLT1:P1|Operator error in Kongsberg
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|electrical|pressure transducer|defect locations onshore|montasje|initial direct product problem|material|GFS SCM 07  Bytting av trykktrandsusere|unknown info root_cause
Q1|100006609|28/02/2003|priority 3 |Q1|PETROBRAS|unknown info region|NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|campos basin|root cause engineering|other product design error|SCM 2 Roncador Tube conflict inside can|unknown info root_cause
ZF|7104033|16/08/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTE NOCO|assembly test|handling damage|scm electrical|other scm electrical|operation maintenance|handling transportation lifting error|440 v on HXT/SCM dur. skidding on TOA|Wrong handling on deck during SU test
ZF|7105129|13/06/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly test|documentation general|scm electrical|other scm electrical|engineering|design specification drawing error|4 PIN CONNECTOR INSTEAD OF BLANKING PLUG|Error in configuration engineering
Q3|7104670|21/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations offshore field|heidrun tlp|initial direct product problem|function|No comms with FSM via SCM well D-2H|Damaged connector on FCM harness(SCM OK)
Q1|7103234|13/07/2000|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|mechanical|outer can|ext. loc. st.johns (canada)|goods receipt|initial direct product problem|leakage|Compensation bladder extruded and burst|unknown info root_cause
ZF|P6000100953|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|machining|thread error|scm hyd mech components|outer can|other causes damage|no noncompliance|To short threads in outercan|Interface with EC adapter verified OK
ZD|P6000077632|21/09/2015|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOTE NOCO|documentation|procedure process error|scm|scm|intercompany|kongsberg|Defect on delivery|Certification Issue
ZB|100050519|26/02/2015|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|scm|scm|other external causes|customer error responsibility|SCM# failure after reworks|outside warranty period
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|NOCO NOPT NOTE|test|function|scm electrical|other pcbs|vendor|equipment malfunction|SCM 15  SEM A Analog Card & HP PT Angus3|unknown info root_cause
ZF|3801623|28/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|NO VACUUM DURING FILLING OF OUTERCAN|unknown info root_cause
ZF|100005667|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|100034440|03/01/2006|priority 3 |Q3|LLOG|unknown info region|NOCO NOPT ATCO NOTE|assembly test|function|scm|scm|assy|operator error|HIGH RESISTANCE VALUE|Higher Resistance than Specification
Q3|100016901|15/01/2003|priority 3 |Q3|BP|GOM|NOPT NOCO NOTI|scm rcm|scm|ext. loc. kos houston|work shop|root cause assembly test|workshopassembly test error|o-ring on EC2 on top of SCM clipped|unknown info root_cause
ZF|P6000063633|01/07/2011|priority 3 |Q3|ENI|unknown info region|NOPT NOTE ATCO NOCO|test|missed operation|scm|scm|engineering|procedure error|incorrect rev of procedure is used|Follow-up in QN200214316
ZF|P6000098616|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|NOTE NOPT NOCO ATCO|assembly test|function|scm|scm|vendor|vendor design error|HFT ACCEPTANCE CRITERIA NOT MET|HFT DOC. & TEST UNIT DISCREPANCY
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|NOTE ATCO NOCO|change deviation request|conversion approval|scm|scm|intercompany|kongsberg|SCM Change Hydraulic Fluid|SCM shipped to be reflushed
ZF|100050383|19/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|assembly test|function|scm|scm|engineering|engineering error|Diode missing between SEM A and SEM B|Missing diode-coupling in DO-outputs
ZD|P6000065528|04/04/2011|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|machining|outside diameter error|scm|scm|vendor|specification not followed|blindelokket passer ikke til ytterkanna.|Dim on blind plate does not fit OC
ZF|100037965|27/06/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|SCM I05  HFT  PRD voltage clarification|Typo in procedure.
ZF|P7000000897|03/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|Flowmeter HP not reading|It was not possible read minimum flow
ZB|7104075|30/03/2009|priority 2 |Q1|SHELL|GOM|ATCO NOCO NOPT NOTE|test|function|scm el. act.syst|control electronics|test|operator error|Control Failure/Issue|Operator Error
ZF|7104670|14/08/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|assembly test|workmanship general|scm mech w mb|one atmosphere canisters|assembly test|assembly test error|Failure on SIO-card ?|Filling port not closed.
ZF|P6000088604|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q1|7101401|22/05/2002|priority 2 |Q1|PETROBRAS|unknown info region|NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|leakage|SCM 4 Marlim untight screws in block|unknown info root_cause
ZB|100048038|13/12/2006|priority 2 |Q1|CHEVRON|WEST AFRICA|NOPT ATCO NOCO NOTE|assembly test|missed operationassy test|scm|scm|assy|operator error|SCM LP return leaking.|Wrong Pressure used to function SCM
ZF|P6000083428|04/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|other defect|functional|scm el opt components|other el opt components|test|incorrect set up testing| Error on SALD sensor|Faulty test equipment
Q3|7102969|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|mechanical|locking mechanism|defect locations onshore|workshop other|problem causes defect causes|service|Bytte av solonoider og senterlås.|unknown info root_cause
Q3|7101172|06/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM no reply when polling|unknown info root_cause
ZF|P6000100953|05/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|specification error|computer system software|sem tpu config|engineering|engineering error|Wrong Signature curves|unknown info root_cause
ZF|100037966|05/07/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|user documentation procedures|scm|scm|engineering|engineering error|PRD-0000025022 Needs Updating|SCM -XT comm  procedure incorrect
Q1|3812476|11/09/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations offshore field|norne fpso|initial direct product problem|function|SCM 1 Norne B-2H clogged ret. checkvalve|unknown info root_cause
Q3|7103233|15/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|Customer comments to Manufact. Data Book|unknown info root_cause
Q3|7102643|unknown info defect_date|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|electrical|pressure transducer|defect locations offshore field|transocean searcher|initial direct product problem|leakage|Åsg SCM 10  Hyd leak line 17  Well I-4H|Pressure Transducer top blown off
ZF|P7000039672|01/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000037215|05/05/2011|priority 3 |Q3|ENGIE|NORTH SEA|ATCO NOTE NOPT NOCO|other defect|part lost|electric products|other electric products|projects|documentation error|Unit still in KOS2 but is in Kongsberg|Part listed as located in wrong place
ZF|P6000104111|09/03/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|damaged during testing|object types to eng matl class|scm|test|damaged during testing|Child QN on P21-SCM|Operator error
ZF|P6000102554|25/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7101463|14/12/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MEG # 10 SCM Refurbishment.|unknown info root_cause
ZF|P6000073687|26/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|damage|damage during testing|scm hyd mech components|hydraulic coupler|test|damaged during testing|HC6 coupler damaged|HC6 coupler damaged
ZF|100017278|08/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|SCM retrieved not maintain acc. to stand|unknown info root_cause
ZF|P7000016420|19/05/2011|priority 1 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|assy|operator error|Falha PT Interno do SCM.|Wiring error
ZF|100068622|28/07/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|scm el opt components|other el opt components|test|tooling|Not able to perform WGM/MFM test in HFT|No available CPI test equipment.
ZD|100052231|13/02/2014|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|physical|scm hyd mech components|outer can|vendor|operator error|Damage to outer can’s EC ports|unknown info root_cause
ZF|P6000103208|20/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extended test
ZF|P6000108542|27/12/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|change deviation request|process substitution request|object types to eng matl class|scm|other causes damage|cause not found|RIT scope unable to be fully performed.|Waiver for MPFM RIT Test
ZF|P7000016420|27/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|imension (tolerance)|scm hyd mech components|baseplate|vendor|specification not followed|Base plate com problema dimensional|USILIDER - BASE PLATE
ZF|P6000122626|03/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|test|function|scm sem el opt component|other scm sem el opt components|engineering|procedure error|Voltage reading outside acceptance crit.|Creiteria readings not acc to procedure
ZD|3787101|25/09/2009|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|leakage (fluid)|scm|hydraulic valves|vendor|operator error|External leakage control valve|Holes for namepl drilled into hydr. line
ZF|100048038|29/03/2007|priority 2 |Q3|AGBAMI|unknown info region|NOTE NOPT NOCO ATCO|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 24|Damage in warehouse handling
ZF|P7000024900|18/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|physical damage|scm sem el opt component|sem mech. components|intercompany|kongsberg|Oxidation on the El can's screws|PO 47612315-4
ZF|7104075|24/06/2005|priority 3 |Q3|SHELL|GOM|NOTE NOCO ATCO NOPT|coating|coating not applied|scm|scm|vendor|do not use|SCM EXTENSION ROD|Coating not applied per drawing
Q3|100017305|29/11/2002|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|No communication XT - SCM 03 SEM B|unknown info root_cause
ZF|7101463|21/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|documentation|procedure process error|topside products|subsea control unit (scu)|intercompany|houston|Missing Sign offs|Missing Sign Offs
ZF|P7000039672|23/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|cleanliness|scm hyd mech components|other hydraulic components|vendor|specification not followed|MARCAÇÃO DE FILTRO NÃO CONFORME|134871 - Pall do Brasil Ltda
ZF|P6000088604|18/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Can bus 1 PT/TT3-A Never detected|Opr. mistake during wiring of SCM
ZB|7104075|24/10/2006|priority 1 |Q1|SHELL|GOM|NOPT NOCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic control valves|assy|operator error|Manatee A2 SCM09 LP2 Leak at COVLP|Assembly & Test error FMC
ZF|P6000074156|06/03/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|CVLP 11 not corrosponding correct|Operator error  during assembly
ZE|P6000055605|22/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|causes for improvement|process procedure not being followed|Wrong pressure on PT when operating CVHP|Operator didn`t pay sufficient attention
ZF|P7000039672|20/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|part lost|scm hyd mech components|other mechanical components|intercompany|kongsberg|Falta do corpo da calha|117094 FMC KONGSBERG SUBSEA AS
ZF|P6000088751|06/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SEM failure detected in extend. test
ZF|P6000069056|16/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTE NOCO|marking|marking content error|scm|scm|other causes damage|cause not found|SCM need to be retagged|unknown info root_cause
ZB|7101172|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|damage|wear & tear|scm|scm|assy|lack of maintenance|Warranty claim 214-Gullfaks leakage I-3H|Wear and tear to valves during operation
ZF|7101463|26/07/2005|priority 3 |Q3|MOBIL EG|unknown info region|NOCO NOTE NOPT ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|component error|SEM FAIL HELIUM LEAK TEST|SEM FAIL HELIUM LEAK TEST
ZF|100056443|26/10/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|NOTE NOCO|change deviation request|unknown info damage_desc|scm|scm|vendor|unknown info cause_desc|Wrong Clock frequency|Vendor recommended TRITON update
ZF|P6000069056|22/08/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|design|dbi error|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|qn cancelled|Itemliste/bom stemmer ikke med merking|BOM configuration item numbering
ZF|7105130|26/11/2006|priority 1 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO NOPT|damage|unknown info damage_desc|scm|scm|other external causes|customer error responsibility|no communication with SCM|customer's error when powering it up
ZF|7104670|21/10/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|test omitted|scm|scm|other external causes|customer error responsibility|Concession_FSM Test in HFT not performed|Tets equipment to be delivered as CPI
Q2|7101401|23/03/2000|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Missing termination resistors in modem|unknown info root_cause
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|electrical|printed circuit board|defect locations onshore|montasje|initial direct product problem|material|Refurbishment  Bytte av trykktransdusere|unknown info root_cause
ZF|100037428|24/04/2007|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOTE|documentation|incorrect user documentation (customer)|scm|scm|assy|manufacturing engineer erorr|HFT procedure needs update|unknown info root_cause
Q3|100020278|18/11/2002|priority 3 |Q3|EXXONMOBIL|unknown info region|NOTI NOCO NOPT ATCO|hydraulic|hydraulic control valves|defect locations onshore|fat|initial direct product problem|leakage|SCM CVs are leaking after PT Cycle test|Refer to QN200013753 for cause
Q3|7105128|08/01/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|mechanical|outer can|defect locations onshore|fat|initial direct product problem|dimension|SCM P 01|unknown info root_cause
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Marlim SCM 07-ALFA to 07-GAMA|Wrong materials
ZF|P6000028371|02/08/2011|priority 3 |Q3|SHELL|GOM|NOTE ATCO NOCO NOPT|test|leakage (fluid)|scm|scm|test|improper handling|Contaminated Silicone in SCM|Contaminated Silicone in SCM
ZF|P6000042970|19/10/2010|priority 2 |Q3|TOTAL|unknown info region|NOCO NOTE NOPT|documentation|procedure process error|scm|scm|projects|documentation error|Material not delivered to plant|unknown info root_cause
ZF|P6000121268|16/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|7104075|05/04/2005|priority 2 |Q3|SHELL|GOM|NOPT NOTE ATCO NOCO|assembly test|do not use|scm|scm|engineering|engineering error|Clarify SCM Lab document|SCM Lab document not complete
ZF|100016711|12/12/2003|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|other scm mechanical|assembly test|assembly test error|Failed in pressure test|SCM over-pressurised or plug not torqued
ZF|100017305|23/04/2003|priority 2 |Q3|STATOIL|unknown info region|ATCO NOTI NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|hydraulic control valves|assembly test|assembly test error|Possible Silicon polution in Brayco oil|unknown info root_cause
ZF|P6000069056|07/04/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|vendor|design error|"Deviation from ""no dead end"" principle"|unknown info root_cause
ZF|P6000050867|16/07/2010|priority 1 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|other defect|functional|test and transportation|communication test unit (ctu)|intercompany|kongsberg|DAS loss of communication|DAS loss of communication
ZE|100046112|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|POG - SCM Fault|POG - SCM Fault
ZF|P6000055605|10/10/2011|priority 3 |Q3|SHELL|GOM|NOPT NOTE ATCO NOCO|documentation|procedure process error|scm|scm|engineering|continuous improvement|Hyperbaric procedure must be updated|Procedure updated acc. to marups
ZB|100020562|02/12/2009|priority 1 |Q1|BP|GOM|NOTE NOCO ATCO|test|function|scm|scm|test|missed operation|Bad reading on NOVA DHPT|Bad reading on NOVA DHPT
ZF|P6000042969|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT|other defect|unknown info damage_desc|fks quality system issues|quality management system|other causes damage|unknown info cause_desc|Rosa 301 SEM A failure|unknown info root_cause
ZF|100031223|03/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|compensators|assembly test|operator error|THE SCM IS LEAK|Plug not tightened.
ZF|P6000088626|28/11/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly|interface issue|scm hyd mech components|hydraulic tubing|fabrication shop personnel|operator error|P6000121475 Wrong measurment.|Wronly bent  DWG not followed
ZF|100052701|13/04/2010|priority 4 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|documentation|incorrect certificates records|scm|scm|intercompany|kongsberg|F&D SCM drained.marked whit n/a|Missing marking on silicone level
ZF|100050519|21/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|procurement|vendor did not complete required work|scm hyd mech components|other hydraulic components|vendor|equipment malfunction|SCM RELIEVING AT 5 PSI|SCM RELIEVING AT 5 PSI
ZF|100037967|22/01/2008|priority 1 |Q3|BP|unknown info region|NOTE NOCO NOPT|assembly test|function|scm|scm|materials stores|improper packaging & storage|SEM A FAILURE ON MCM S1|unknown info root_cause
ZE|P7000008275|05/04/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|variance|handle tooling issue|RCA - empenamento dos stabs Outer Can|Interferência entre ferramenta e peça
ZE|100046112|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Angel - SCM Issue|SCM Issue
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|NOCO ATCO NOTE NOPT|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|Non functioning PT|Non functioning PT
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 01|Software improvement/correction
ZF|P7000000897|10/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Function  CVHP53 and CVHP54 are crossed|unknown info root_cause
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|NOTE NOCO ATCO|damage|damage during assembly|connectors|electrical optical|other causes damage|qn cancelled|SCM11 connector damaged|unknown info root_cause
ZF|P6000063531|20/04/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|object types to eng matl class|scm|other causes damage|cause not found|ALD test failed during mobilization|Test equipment verified OK
ZF|P7000016420|09/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm el opt components|el. connector|vendor|assembly error|Rosca do conector travada|ODI - Conector eletrico de base
ZB|P6000065886|04/09/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|wear & tear|customer compliant|unsatisfactory customer satisfaction|engineering|continuous improvement|Marulk / Norne Claim 224 Leakage on SCM|ECN 6130063  - design improvement
ZF|P7000024900|08/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|component error|scm hyd mech components|check valve|vendor|equipment malfunction|Check Valve out of Acceptance Criteria|1242 - HTS Maskinteknikk AS
ZF|100037428|17/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOPT NOCO NOTE|test|wrong test procedure used|scm|scm|engineering|procedure error|MPFM outside acceptance criteria|Wrong requirements in procedure
ZB|100020562|17/03/2008|priority 1 |Q1|BP|GOM|NOCO ATCO NOTE NOPT|other defect|functional|scm electrical|pressure transducers|vendor|equipment malfunction|PT on CIT2 is giving false reading|Pressure Transducer Failure
Q3|7103233|unknown info defect_date|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|DSP-0010466 at rev0 (issued for review)|unknown info root_cause
ZF|100017305|28/04/2003|priority unknown info priority|Q3|STATOIL|unknown info region|NOPT NOCO NOTE ATCO|assembly test|workmanship general|scm mech w mb|other scm mechanical|other causes|logist.handling packing shipping error|Feil transport skid brukt ved transport|feil  transp. skid
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000088751|06/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|electronic boards|dhi|engineering|specification error|No communication with  DHI212.2 Sem A|Eng.err.  wrong length on ribbon cables
ZF|P6000055605|01/09/2011|priority 3 |Q3|SHELL|GOM|ATCO NOPT NOCO NOTE|test|function|scm|scm|other causes damage|cause not found|PT18 don`t work|unknown info root_cause
Q3|7102643|20/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations offshore field|viking poseidon|initial direct product problem|dimension|SCM leaks offshore  flushing pipe bent|Check valvefitting damaged when handling
Q3|3812476|11/01/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOTI NOPT NOCO ATCO|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|leakage|SCM leaks via return line to sea (E3-AH)|LP accumulator leak/O-ring replaced
ZF|100055762|22/08/2007|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly test|interface of components issue|scm|scm|vendor|fabrication error|Bad threads on  vacum plug|xylan coating on threads in baseplate
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE ATCO NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 10|Software improvement/correction
ZF|100037229|29/04/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOPT NOTE|test|function|test and transportation|other scm test & transport equipment|test|tooling|MMR - Pressure drop in the hyperbaric|unknown info root_cause
ZF|P7000000897|14/09/2011|priority 2 |Q3|SHELL|unknown info region|NOPT NOTE ATCO NOCO|marking|no marking|ss compl. & w.over xt general|tree assembly|other causes damage|cause not found|Marcação Incorreta|FMC BRAZIL
ZE|P6000088614|07/05/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|causes for improvement|documentation|SCM  Improvement Propossal - HFT60078748|Update of procedure.
ZF|P6000098616|27/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|documentation|procedure process error|scm|scm|engineering|specification error|HS CAN bus grounding error on CPU card|ISO GND missed in wiring specification
ZF|100037965|15/01/2008|priority 1 |Q3|BP|unknown info region|NOCO NOPT NOTE|documentation|incorrect certificates records|scm|scm|other causes|no noncompliance|screw M10 & larger missing batch number| use as is with batch certificates
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly test|interface of components issue|scm|scm|engineering|engineering error|Replacement of strainer|Conflict between strainer and SCMMB
ZF|P7000039672|12/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|common misc fasteners metric|screw|vendor|final inspection error|Parafuso com o comprimento maior|124086 PARNOX IND E COM DE ARTIGOS IND L
ZB|7102969|04/02/2007|priority 4 |Q1|MOBIL EG|unknown info region|NOTE NOCO ATCO|assembly test|function|subsea sensors (not in scm)|pressure transmitter (pt)|engineering|engineering error|Unable to communicate with Quantex DwnHl|unknown info root_cause
ZF|100037427|19/05/2007|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other causes|no noncompliance|leakage from LP1 & HP1 when LP2 press.|No failure
ZF|P7000039672|10/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Vazamento na adapter plate de LP PS#13|123643 - BOSCH REXROTH  LTDA
ZD|100020278|27/05/2011|priority 3 |Q2|EXXONMOBIL|unknown info region|NOPT NOTE ATCO NOCO|marking|no marking|scm|scm|vendor|specification not followed|no revision letter on part|no revision letter on part
Q3|100017305|08/11/2002|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM water in return lines|unknown info root_cause
ZB|100020562|22/09/2008|priority 2 |Q1|BP|GOM|NOCO NOTE NOPT|test|function|scm electrical|dhi pcbs|vendor|equipment malfunction|Nova gauge lost power|Nova gauge lost power
ZF|P6000081371|14/06/2012|priority 3 |Q3|SHALLOW WATER SCM|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|outer can|engineering|specification error|problem assemle the name plate|Problems attaching Nameplate on OC
Q3|7101172|06/03/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM  internal leakage on LP line (F-4H)|Contol Valve leaking
ZF|P6000055605|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|procedure error|scm|scm|engineering|procedure error|FSK to QAM procedure needs revision.|FSK to QAM procedure needs revision.
Q3|7102643|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|product defects for dept.|scm|defect locations offshore field|transocean searcher|problem causes defect causes|service|SCM not contactable by address nr.|SEM address correct  no fault found
ZD|P6000055605|16/02/2015|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|documentation|procedure process error|scm|scm|vendor|design error|Damage/Shell/SCM/Lost Communication|25AF52 SCM Lost of Communication
ZF|P6000145982|25/07/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|damaged during testing|object types to eng matl class|scm|test|damaged during testing|SEM  Damaged MRM/LNCT Card|Needs to change MRM/LNCT Card
Q3|100020562|30/08/2002|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|electrical|sem el.rack|ext. loc. kos houston|work shop|root cause engineering|design specification error|BP IWOCS & TH SCMs  same SEM address|Not picked up during contract review
ZD|P6000042968|20/07/2009|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|missing certificates records|ss compl. & w.over xt general|tree assembly|vendor|operator error|certification|VL - Missing Full Cert Pack
ZF|7104033|07/05/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|ss intervention running tool|scm running tool|other external causes|customer error responsibility|Silicone leak in SCM -Compensator broken|Customer resp./storage error
Q3|7105128|09/01/2002|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO|scm rcm|scm|defect locations offshore field|girassol fpso|initial direct product problem|function|SCM 06 Girassol PT HP Supp. unstabile|unknown info root_cause
ZF|P7000016420|22/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|coating plating|incorrect colour coating|scm|scm|other causes damage|planning error|Revestimentos em desacordo com DBI|unknown info root_cause
ZD|P6000069820|07/07/2011|priority 2 |Q2|CONOCOPHILLIPS|unknown info region|NOTE NOPT ATCO NOCO|coating plating|coating defect|scm|scm|vendor|damage during transport|(SS) Coating  Peel-Off  & Scratches|Coating  Peel-Off  due to Handling
ZB|100050519|20/10/2009|priority 2 |Q1|MOHO BILONDO|unknown info region|NOTE ATCO NOCO|design|specification error|scm|scm|engineering|engineering error|Sensor communication failure|Software error in SCM
ZF|P7000016420|13/10/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|marking|no marking|scm|scm|other external causes|customer error responsibility|Screws whithout Batch marking|Batch number
ZF|100038200|07/10/2010|priority 3 |Q3|SHELL|unknown info region|ATCO NOCO NOPT NOTE|documentation|incorrect certificates records|scm|scm|projects|documentation error|Incomplete databook|missing signoff and n/a section
ZB|P6000133916|28/11/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|coating plating|coating defect|object types to eng matl class|scm|documentation requirement|process step not followed detected|Touch up paint on SCM#12|unknown info root_cause
Q3|100018600|28/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOPT ATCO NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|B electronic don't switch off MFM power|unknown info root_cause
ZF|100051269|23/11/2007|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|damage|damage during testing|scm|scm|other causes damage|unknown info cause_desc|VGS B&B38 Mob. SCM  11 fail during HFT|Operator error
ZF|100048038|12/04/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE ATCO NOPT NOCO|assembly test|function|scm|scm|other external causes|customer error responsibility|LP pressure changes AGB SN 21|New requirements from customer
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOTE NOCO NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #15 Wiring|BPTH SKOFLO SCM SN #15 Wiring
ZF|100031223|06/05/2010|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|drawing error|scm|scm|engineering|dwg error|Error in drawing.|Wrong Screw used for HP  valve / adapter
ZF|P6000105542|10/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN20|Wrong welding pin defined for man. block
ZF|P6000074156|10/02/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hyd mech components|outer can|assy|operator error|Tubing not mounted correct|Parts assembled incorretly in workshop.
ZF|P6000105542|02/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|scm|scm|projects|customer error|Unable to perform test according to HFT|Concession request.
ZF|P7000039672|10/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|physical damage|scm hyd mech components|hydraulic tubing|assy|damaged during assembly|Tubo danificado durante montagem|unknown info root_cause
ZF|100027228|11/04/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI|assembly test|function|software fks provided|sem|engineering|miscellaneous product design errors|"FAIL DURING DHI 109 ""PSM"""|unknown info root_cause
ZF|100030542|04/04/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOCO NOPT NOTE|documentation|incorrect user documentation (customer)|sensors|scm flowmeter|engineering|engineering error|COM test on SCM 24|Wrong accept. criteria in PRD-0000022442
Q3|7104020|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|Silicone oil is not sampled in procedure|Check missing in procedure
ZF|P7000000897|01/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT4 fail.|It was not possible read pressure values
ZF|P7000000897|20/12/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|leakage (gas)|scm|scm|vendor|material error|Vazamento|unknown info root_cause
ZF|7102969|19/05/2006|priority 3 |Q3|EXXONMOBIL|unknown info region|NOPT NOCO NOTE ATCO|assembly test|function|scm|scm|vendor|component error|INTERNAL PT OUT OF RANGE|INTERNAL PT OUT OF RANGE
Q3|7103233|06/03/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|fks el.lab|initial direct product problem|documentation|Testing not done to CSA requirement|TPR-0010791 not updated to requirements
ZB|100018820|25/04/2003|priority 3 |Q1|EXXONMOBIL|NORTH SEA|NOTE NOCO NOPT|assembly test|function|scm electrical|pressure transducers|purchasing|miscellaneous|SCM 1 Sigyn PT Func. MIV unstable|unknown info root_cause
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of resources|CAR 2 RCA Actions_2 from RPT10033107|unknown info root_cause
Q3|7104670|10/05/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations offshore field|heidrun tlp|initial direct product problem|function|SCM communication problems|Not known
ZD|P6000069820|20/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PART NUMBER|INCORRECT PART NUMBER
ZF|P6000069056|29/09/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|design|dbi error|common misc fasteners metric|screw|engineering|dbi error|Missing batch-management on 200017100|Wrong ECN class used.
ZF|100035119|25/11/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|project|project requested unfinished shipment|electronic boards|dhi|other external causes|customer error responsibility|Company request to not installe DHI|unknown info root_cause
Q1|7101172|05/03/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|unknown info damage_group_desc|unknown info damage_desc|defect locations offshore field|deepsea trym|initial direct product problem|leakage|Silicone oil leaking between HXT and SCM|Not yet known  still subsea
Q3|7105128|18/11/1999|priority 1 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|mechanical|outer can|defect locations onshore|tank test|initial direct product problem|leakage|SCM P 04|Compensator was not installed
ZB|P1000004979|17/01/2008|priority 3 |Q1|BP|unknown info region|NOPT NOTE NOCO|test|function|software fks provided|sem|test|missed operation|SEM B sensors reading too low|SEM B sensors reading too low
ZF|7104033|29/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|damaged during testing|scm sem el opt component|other scm sem el opt components|marking|incorrect marking|Too high voltage used on SCM (388 VAC)|Error on name plate.
ZF|P7000039672|18/12/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|leakage (fluid)|scm hyd mech components|outer can|test|damaged during testing|Vazamento nos o-rings dos stabs|unknown info root_cause
ZF|P6000068902|02/12/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|functional|electronic boards|main boards cpu & i o|test|missed operation|No reading from PT 11|W03 replaced as a  precautionary measure
ZF|P6000093498|06/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|component error|electronic boards|other eletronic boards|test|damaged during testing|SUPS failing during load test|Ref ZD QN 200386252
ZF|100037966|20/09/2006|priority 3 |Q3|BP|unknown info region|NOTE ATCO NOCO NOPT|assembly test|function|scm|scm|assy|operator error|SCM being returned for flowmeter problem|wiring error during assy
Q3|100020278|07/03/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|user documentation error|Various SCM drawings need updating|FKS drawing errors
ZF|100037428|08/09/2005|priority 3 |Q3|TOTAL|WEST AFRICA|NOPT ATCO NOTE NOCO|coating|coating defects|scm|scm|other causes|do not use|Bad finish on outercan.Quality issue.|RAL code allows different colour shades
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly test|interface of components issue|scm|scm|engineering|engineering error|Replacement of strainer|Conflict between strainer and SCMMB
ZB|100037965|05/04/2016|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|service :|lack of training|ETU Setup file loading configure setup|unknown info root_cause
ZF|P6000074156|14/03/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|missing certificates records|vendor quality system issue|quality management system|other causes damage|qn cancelled|ATS-Missing Documentation|ATS documentation missing
Q3|7104033|20/01/2000|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|mechanical|outer can|defect locations onshore|workshop|initial direct product problem|marking|Damage may occur due to wrong coupling|Mulighet for feilkobling av Connector`s
Q3|7104670|unknown info defect_date|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|material|Bytte av poppet i Hydr. koplere.|unknown info root_cause
ZF|100015538|29/10/2003|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|service maintenance|unknown info damage_desc|scm mech w mb|other scm mechanical|operation maintenance|maintenance error|Piping (HP & LP) on SCM|URT SCM interface modified
Q3|7102643|22/11/2000|priority 3 |Q3|ÅSGARD|unknown info region|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|HP PT readings fluctuate  Well M-3H|Not known
ZF|100034440|08/08/2008|priority 1 |Q3|HOUSTON STOCKING MK IV|unknown info region|ATCO NOCO NOTE NOPT|damage|damage during transport|scm|scm|other causes damage|damage during transport|Possibly Damaged|Possibly Damaged
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|test|function|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
Q3|7104670|26/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|Tilbakekalt modul (SIO-kort)|unknown info root_cause
ZF|P7000008275|30/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|scm|scm|test|incorrect set up testing|Finalização do teste hiperbárico TBU#1|MMR Rio
Q1|7103233|10/08/2000|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTI NOPT|hydraulic|chemical control valves|ext. loc. st.johns (canada)|goods receipt|initial direct product problem|leakage|SCM CIDV leaking? Retested - no leak|No fault
Q3|7104075|14/11/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|electrical|sem baseplate penetr. & rcm penetrators|ext. loc. kos houston|work shop|initial direct product problem|leakage|silicon fluid found inside of SEM cans|unknown info root_cause
ZB|100020278|22/04/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE NOPT ATCO|test|function|scm hydraulic|other scm hydraulic|other causes damage|cause not found|Well SS-3 # High SCM Return Line Press.|Well SS-3 # High SCM Return Line Press.
ZF|P7000016420|20/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|electronic boards|other eletronic boards|engineering|specification error|Medições SEM A 230v Supply|Tensão fora criterio
ZF|P6000065528|20/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Not possible to connect the outer can|Human error in wiring
ZF|100052231|01/02/2007|priority 1 |Q3|CHEVRON|GOM|NOTE NOCO NOPT ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|component error|An abnormal leakage on SCM|failure caused by unstable check valves
Q3|7100320|17/12/2001|priority 3 |Q3|PETROBRAS|unknown info region|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|function|SCM 8 Hercules AI/AIDO board failure|unknown info root_cause
ZF|100026567|11/09/2003|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly test|marking|scm mech w mb|outer can|engineering|miscellaneous product design errors|Updating of Assy DWG VIGDIS SCM|Feil på tegning
ZF|7104075|29/01/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly test|function|scm|scm|vendor|component error|SEM A not reading values|unknown info root_cause
Q2|7104670|12/09/2000|priority 2 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE|electrical sensor equipment|electrical pin connetors|defect locations onshore|workshop|initial direct product problem|function|Lock rings on tronic connector to wide|unknown info root_cause
Q3|100018600|06/02/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTE NOCO ATCO NOPT|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|No contact w/EC14 when SCM engaged on MB|SIT proc. for SCM install. not followed
ZF|P6000068902|08/12/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|damage|damage during transport|scm|scm|vendor|coating defect|Transport defect on coating|Transport damage on coating
ZF|P7000024191|19/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|test omitted|scm|scm|test|incorrect set up testing|SRT - GLOBAL #16 CAN BUS AND SERIAL LINE|Lab Test Box with problem.
ZB|7101172|14/09/2006|priority 4 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly test|function|scm|scm|vendor audit|unknown info cause_desc|Failure on valve response on system II|AI-card failure on SEM-A
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte av solonoider på ventiler.|unknown info root_cause
Q3|7104075|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|mechanical|outer can|defect locations onshore|customer goods receipt|initial direct product problem|dimension|SHE SCM 02|To be checked in workshop
ZB|100017278|08/01/2010|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|test|unknown info damage_desc|scm|scm|test|operator error|F&D 10 Åsg  To many couplers on SCM|Too many couplers on SCM
ZE|P6000121393|05/10/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|hydraulic products|coupler|variance|capture mistake|HC1 LEAKING|Leakage on coupler
ZF|P6000065886|15/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|design|dbi error|scm hyd mech components|hydraulic fittings|engineering|dbi error|Remove PN: DP-48-1903|BOM error
ZD|P6000125392|04/05/2016|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|incorrect certificates records|scm|scm|vendor|specification not followed|Quality Issue|unknown info root_cause
ZE|P6000074156|12/04/2017|priority 3 |Q3|SHELL|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|test|tooling malfunction|Shell  SCM  Fluid Leaks|unknown info root_cause
ZB|P6000080343|27/09/2012|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|machining|position error|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Warranty Claim SCM MKll Jubilee phase 1A|FMC Dunfirmline produced incorrectly
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTE NOCO|assembly test|do not use|fks quality system issues|resource management|assy|missing operation|Not performed HFT do to lack of time|PSM not followed  short mob time
Q3|7106268|11/02/2002|priority 3 |Q3|TOTAL|unknown info region|NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|pride angola|initial direct product problem|function|MIV PT is malfunctioning during test|PT defective
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|unknown info region|NOTE NOCO NOPT ATCO|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips inside the HP-Config Plug|Parts not cleaned by supplier.
ZE|P6000088626|17/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|drawing error|scm hyd mech components|outer can|certification|requirements not followed|Torque tool (tt) interface on MCM and HC|Top plates not acc to TT API 17D std
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000029772|13/08/2009|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|marking|marking content error|scm|scm|engineering|dwg error|SRM marking error|GA drawing error
ZD|P6000042968|02/02/2010|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|missing certificates records|common misc fittings|other|intercompany|kongsberg|certification|VL - Cert Issue
ZF|100017278|28/08/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly test|do not use|scm|scm|other causes|do not use|Error in config file.|QN provided by mistake
ZF|7103479|29/08/2005|priority 3 |Q3|SHELL|unknown info region|NOTE NOCO ATCO NOPT|damage|damage during transport|scm|scm|other external causes|customer error responsibility|BOLTS TO EL. BRACKET IS BROKEN|Too high torque during untorque from XT
ZF|P6000068918|04/01/2012|priority 3 |Q3|TOTAL|unknown info region|NOCO NOTE ATCO NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wrong twisted pair on EC2|Operator did not follow the procedure
ZF|P6000077638|08/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|damage|damage during testing|scm|scm|engineering|engineering error|Too bad space in SEM|Human mistake in SEM configuring
ZB|P6000043714|08/04/2009|priority 1 |Q1|PETROBRAS|GOM|NOTE ATCO NOPT NOCO|test|function|scm electrical|other scm electrical|vendor|equipment malfunction|Communication Problem with SMPFM|Communication Problem with SMPFM
ZF|P7000024191|11/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|missed operation|scm|scm|test|incorrect set up testing|Testado em desacordo com o Procedimento|unknown info root_cause
ZF|100020562|18/10/2004|priority 2 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|compensators|assembly test|assembly test error|Water ingress in SCM from strainer assy?|Nut not properly torqued.
ZB|P6000055605|04/02/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|documentation|incorrect user documentation (customer)|scm|scm|qa qs qi|documentation error|MRB review comments from Shell|documentation errors in MRB
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|purchasing|unqualified vendor used|SCM bladder ruptured 18h after top-up|Unqualified Vendor used
ZF|100037428|12/04/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|other defect|functional|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|Too low output voltage from DHI boards|unknown info root_cause
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 06|Software improvement/correction
ZF|P6000121393|22/05/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage during testing|scm|scm|test|incorrect set up testing|Too high voltage vrong way|Wrong termination in hyperbaric test
ZB|7104075|17/01/2008|priority 2 |Q1|SHELL|GOM|NOPT NOTE ATCO NOCO|test|function|scm electrical|other scm electrical|vendor|equipment malfunction|EA5-SCM13-LineA|EA5-SCM13-LineA
Q3|7104033|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|documentation|unknown info notification_desc|Document list was not updated.
ZF|100052701|11/09/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly test|function|electronic boards|other eletronic boards|vendor|fabrication error|Bad soldering on CFG 600 boards|Vendor wormanship & FMC design error
ZF|P7000039672|12/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|imension (tolerance)|scm hyd mech components|other mechanical components|vendor|specification not followed|Espessura menor / Logo FMC vermelho|123608 - ARTE COLLOR INDUSTRIA E COMERCI
ZF|P6000058949|05/07/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|assembly|assembled incorrectly|hydraulic products|coupler|assy|damaged during assembly|Change hydraulic coupler|Sharp edge on Male coupler   test equip.
Q2|7102969|19/04/2002|priority 3 |Q2|EXXONMOBIL|unknown info region|NOTE ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MEG SCM 24 Damaged in shipping|unknown info root_cause
ZF|100017997|25/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|drawing error|scm hyd mech components|outer can|engineering|dwg error|GA dwg needs update to be useful for FI|GA dwg needs more info
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 02|Software improvement/correction
ZD|100020278|04/11/2005|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO|design|do not use|scm|scm|other causes|logist.handling packing shipping error|Missing Documentation|Lost documentation
ZB|P6000064909|10/06/2016|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|electrical|performance|fks quality system issues|quality management system|electrical|other specify in comments|Defect Not. 04 - SCM No.10|cause unknown - no liabiliy for FMC
ZF|100033987|02/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|assembly test|dimension (tolerance)|scm mech w mb|outer can|engineering|design specification drawing error|THE OUTER CAN DONT FIT|Design is too tolerance sensitive.
ZB|100020278|23/11/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOPT NOTE NOCO|test|function|scm|scm|vendor|equipment malfunction|08-MEGI-015: AIB Voltage Reference Error|AIB Vol Ref Error
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|NOCO NOPT NOTE|test|function|scm electrical|power supply|vendor|equipment malfunction|SCM 14 24Volt PS Manatee2|SCM 14 24Volt PS Manatee2
ZB|100038200|16/05/2008|priority 3 |Q1|ANADARKO|unknown info region|NOTE NOCO|test|function|scm electrical|special electronics.|vendor|unknown info cause_desc|"RAM Error Warning On ""A ""Side"|RAM Error Warning On A Side
ZF|P6000068770|13/08/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|assembly|assembled incorrectly|scmmb|el. connector|other causes damage|qn cancelled|Incorrect assembly of El. Connector EC 7|Failure is on EC7 on EDP not SCM.
ZF|P7000000897|21/09/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|machining|outside diameter error|scm|scm|vendor|operator error|dimensões não correspondem com DBI.|FORNECEDOR NÃO IDENTIFICADO
Q1|100001156|12/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|gullfaks c|initial direct product problem|function|DHPT GFC M-1H malfunct. (drop out)|unknown info root_cause
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO DLFL ATCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P6000093501|09/01/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100054943|14/02/2008|priority 3 |Q3|WOODSIDE|unknown info region|NOCO NOTE NOPT|documentation|missing certificates records|fks quality system issues|product realization|other causes|logist.handling packing shipping error|Batch numbers missing|unknown info root_cause
Q3|7106268|17/10/2001|priority 3 |Q3|TOTAL|unknown info region|NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|pride angola|root cause assembly test|workshopassembly test error|SCM overpressurized (540 bar)|Testing error
ZF|100018820|27/05/2003|priority 3 |Q3|EXXONMOBIL|NORTH SEA|NOPT NOTE NOCO ATCO|service maintenance|unknown info damage_desc|scm hydraulic|other scm hydraulic|engineering|design specification drawing error|SIGYN SCM1 A-3H HP-internal leak|Wrong bolt used
ZB|100017997|03/05/2010|priority 2 |Q1|BP|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (fluid)|scm hydraulic|other scm hydraulic|other causes damage|cause not found|Hydraulic leakage in SCM Silicone|Hydraulic leakage in SCM Silicone
Q3|7101401|02/12/1999|priority 2 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOTI NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrade Marlim SCM 02-ALFA to 02-OMEGA|Wrong materials
Q3|3794920|28/12/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Subsea control module|unknown info root_cause
ZF|P6000042968|31/03/2009|priority 3 |Q3|TOTAL|WEST AFRICA|NOPT NOCO NOTE|other defect|unknown info damage_desc|scm|sem|other external causes|unknown info cause_desc|SW problems|unknown info root_cause
ZB|P6000080678|26/02/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|documentation|procedure process error|scm|scm|service :|lack of training|WEL SCM  PSM not followed|unknown info root_cause
ZF|100064910|09/12/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|drawing error|scm hyd mech components|hydraulic tubing|engineering|dwg error|Tubing too short (p4-p5)|DWG error  corrected and released.
ZB|100017278|17/12/2007|priority 1 |Q1|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|qa qs qi|operator error|Warranty claim 159 - SCM  hydr leakage|Repair not according to requirements
ZD|P6000068912|29/09/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|part lost|scm|scm|intercompany|kongsberg|Missing item (SCM#17) on DN 82065442|Missing Parts
Q3|7102643|02/02/2000|priority unknown info priority|Q3|STATOIL|NORTH SEA|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations onshore|fat|initial direct product problem|documentation|Åsg SCM 34  FAT results mix of procedure|FAT procedure has not been updated
Q3|100017305|11/11/2002|priority 3 |Q3|STATOIL|unknown info region|NOCO NOTI NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM communication problem  XT sensors|unknown info root_cause
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|repair|Shell control module # 4|See description
ZB|7104075|17/01/2008|priority 2 |Q1|SHELL|GOM|NOTE NOPT NOCO|test|function|scm electrical|wiring|vendor|equipment malfunction|SCSSVs Crossed & Reversed|unknown info root_cause
ZF|P7000024191|20/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|MG07 - Montagem do filtro invertido.|unknown info root_cause
ZF|P6000084242|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q1|7102643|06/12/1999|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|product defects for dept.|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM|Communnication failure
Q3|7103233|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|electrical|sem el.rack|defect locations onshore|workshop other|initial direct product problem|function|El rack 'A' test results out of limits|unknown info root_cause
ZF|P6000107981|24/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|functional|scm|scm|test|tooling|To high current draw for MPFM simulator|unknown info root_cause
Q3|7100320|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 11-GAMA til 11-OMEGA|unknown info root_cause
ZF|P7000016420|17/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|other defect|physical|scm|scm|vendor|material error|Adapter plate de retorno danificada.|unknown info root_cause
ZF|P7000001843|15/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|Revestimento não conforme|Pintura
ZB|7104670|22/04/2008|priority 1 |Q1|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|assy|customer error responsibility|D5 SCM does not work|MFM does not workNot retrived gauarantee case
ZF|P7000001621|15/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|other defect|functional|scm|scm|vendor|maintenance|PT's Fora do range Hérc.Ug 15|Reparo de SCM
ZF|100037427|12/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|specification error|computer system software|etu sw|test|incorrect set up testing|Fail in config|Used wrong ETU version during test
ZF|P6000064909|29/09/2011|priority 2 |Q3|TOTAL|NORTH SEA|NOTE NOCO|design|dbi error|common misc fasteners metric|screw|engineering|dbi error|Missing batch-management on 200017100|Wrong ECN class used.
ZF|P6000074156|22/08/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm|scm|test|operator error|(SS) Prelude - SCM Canbus Channel 6 Comm|SCM Canbus Channel 6 Comm
ZF|P6000091085|19/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|design|drawing error|scm hyd mech components|outer can|engineering|dwg error|Wrong drawing.Gas prechage port|Gas port not used on this project
ZF|P6000108542|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extended test
Q3|7101172|24/02/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|All SCMs to have hyd. flow restrictors|Instructions from system engineering
ZB|100001156|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|raw material|defects in material|scm|scm|manufacturing|do not use|Failure on AI card on SEMA  well L-3H|AI card might be of batch with failure
ZF|100036936|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|other defect|functional|fks quality system issues|resource management|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|100020562|07/12/2010|priority 4 |Q3|BP|GOM|NOTE ATCO NOCO NOPT|documentation|procedure process error|scm|scm|intercompany|kongsberg|Concession request on error in document|Error in QAP document
ZB|P6000039844|16/04/2018|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during transport|object types to eng matl class|scm|other causes damage|damage during transport|Shell GK SCM#26 incoming issue|Part received with damaged body in NJ
Q3|7103233|04/04/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI|mechanical|outer can|defect locations onshore|workshop other|initial direct product problem|coating|SCM Outer Cans require paint touch up|Minor handling damage
Q1|7103234|19/06/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM flowmeter bolt broke when removing|unknown info root_cause
ZF|100020562|26/02/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm|scm|engineering|procedure error|BPTH SmartTool V174 EFAT Punchlist Items|BPTH SmartTool V174 EFAT Punchlist Items
ZF|100017305|02/03/2010|priority 3 |Q3|STATOIL|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|service :|improper job preparation|HFT/mob of SCM should be updated|unknown info root_cause
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOTE NOPT NOCO ATCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #12 Wiring|BPTH SKOFLO SCM SN #12 Wiring
ZE|P6000074156|12/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm test stand|pressure regulator|causes for improvement|lack of training|Over Pressurization of SCM's Orange|unknown info root_cause
ZF|100017278|06/04/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|project|project requested unfinished shipment|scm|scm|other external causes|customer error responsibility|Company requested not perform overhaul|unknown info root_cause
ZF|P7000016420|28/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|machining|inside diameter error|scm hyd mech components|baseplate|vendor|specification not followed|Diâmetro não conforme.|unknown info root_cause
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|cleanliness|Dirt found between CVs and solenoids|unknown info root_cause
ZF|100049392|19/09/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO|test|function|scm|sem|other external causes|customer error responsibility|Installation of DIACS-SCM on SYGNA N-1.|Unknown reason for failure
ZB|P6000064909|10/06/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|electrical|performance|fks quality system issues|quality management system|electrical|other specify in comments|Defect Not. 06 - SCM 6 LAGGAN L1Z|cause unknown - no liabiliy for FMC
ZF|7104033|08/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|procedure process error|scm|scm|engineering|continuous improvement|HFT missing towards P/N in SAP|Delivery project not connected the doc.
Q2|7103233|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|hydraulic|hydraulic control valves|defect locations onshore|fat|initial direct product problem|function|The LP valves do not open at min pressur|Testing method at 90 bar.
ZB|100020278|11/02/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO ATCO NOPT NOTE|assembly test|function|scm|scm|vendor|equipment malfunction|SCM 25 communication problem|unknown info root_cause
ZF|P7000024191|25/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT DLFL NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|FALHA NA SEM B|unknown info root_cause
ZF|P6000100953|30/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Failed lekagetest|Too high and unstable leakage from DCVs
ZF|P6000088604|25/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|specification error|computer system software|sem tpu config|engineering|engineering error|HP signature is wrong|unknown info root_cause
ZF|P6000121268|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|7104033|27/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|missing certificates records|scm|scm|qa qs qi|documentation error|Original Production doc. missing|Missing old documentation for MMR work
ZF|100020562|22/10/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|specification error|topside products|n a sw|other causes damage|no noncompliance|BPTH XT SEM Software Punchlist Items|BPTH XT SEM Software Punchlist Items
ZB|7104033|04/10/2016|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|marking|marking content error|scm|scm|test|operator error|GC 187201 wrong tag/use of procedure|Procedures not followed
ZF|100020562|09/03/2010|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|damage|damage from corrosion|scm|scm|other causes damage|damage from wear and tear|EC surface corrosion BPTH Prod XT SCM 1|EC surface corrosion BPTH Prod XT SCM 1
ZF|P6000088604|07/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|marking|marking content error|instrumentation|scm pressure transmitter|assy|operator error|Possible duplicate s/n on Pt`s|SN recorded incorectly at warehouse
ZF|P6000104112|08/07/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|physical damage|scm el opt components|el. connector|assy|damaged during assembly|Locked/cut threads on EC|Threads on EC damaged during assembly
ZF|7103234|11/11/2005|priority 3 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|NOCO ATCO NOPT NOTE|assembly test|missed operationassy test|scm|hydraulic valves|assy|lack of training|Control Valve reset is too high|Testing method
Q3|7102969|01/10/2002|priority 3 |Q3|EXXONMOBIL|unknown info region|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations onshore|goods receipt inspection|initial direct product problem|function|SEM failure|unknown info root_cause
ZF|P7000016420|25/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm sem el opt component|other scm sem el opt components|projects|documentation error|Desvios durante SRT|unknown info root_cause
ZF|P7000008275|24/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|coating plating|coating defect|scm|scm|other causes damage|cause not found|Oxidação na área de montagem do coupler|Ponto de oxidação no manifold block
ZF|100020278|01/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|assembly|wrong part assembled|scm|scm|vendor|assembly error|Pin not fit|Change pin to smaller one which fits
ZF|P7000000897|22/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|scm|scm|test|incorrect set up testing|Mangueiras fora da data de validade|Validade da mangueira
ZF|P7000000897|24/09/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|coating plating|coating not applied|scm|scm|other causes damage|planning error|Revestimento fora da especificação.|unknown info root_cause
ZB|P6000028371|25/02/2010|priority 2 |Q1|SHELL|GOM|NOTE NOCO NOPT ATCO|test|function|scm electrical|processor pcbs|intercompany|kongsberg|Incorrect Main & Alt Program on SCM 201|Incorrect Main & Alt Program on SCM 201
ZF|P6000028371|27/05/2008|priority 3 |Q3|SHELL|GOM|NOPT NOCO NOTE ATCO|other defect|unknown info damage_desc|scm|scm|other causes damage|unknown info cause_desc|change in rev for hydraulic assembly|unknown info root_cause
ZF|P6000039844|28/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|PT/TT 3 SEM A not responding to changes|Wrong marking caused wrong wiring
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 07|Software improvement/correction
ZF|P7000008275|10/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|coating plating|incorrect colour coating|scm|scm|vendor|specification not followed|Teste de vácuo da outer can|Revestimento
ZF|P7000016420|15/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|coating plating|coating defect|scm hyd mech components|baseplate|vendor|coating defect|BASE PLATE COM PONTOS DE OXIDAÇÃO|VENDOR - PONTOS DE OXIDAÇÃO
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTI|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
ZF|7103234|31/08/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly test|miscellaneous|scm hydraulic|other scm hydraulic|engineering|procedure error|Complaint of errors in test procedures|unknown info root_cause
Q3|100005667|13/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|Tests missing in procedure PRD-0010217|unknown info root_cause
ZF|100026567|12/05/2003|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Wrong top  plate|unknown info root_cause
ZF|100052701|18/09/2007|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly test|dimension (tolerance)|scm|scm|engineering|engineering error|Isolation plug for 12 pin digitr. Conn.|Hole is too small for twisted wiring
Q3|7101172|19/03/2001|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|scm rcm|scm|defect locations onshore|workshop|root cause vendor|material component error|CHECK COMMUNICATION WITH SAND-DETECTOR|SIO CARD: UPDATING MAY HAVE BEEN MISSING
Q3|7103233|19/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|function|Install hydaulic flow restrictors|unknown info root_cause
ZF|P6000068902|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000104112|22/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm sem el opt component|other scm sem el opt components|vendor|material error|Fiber outside of acceptance criteria|Common follow-up in QN 200384383
ZF|P6000138867|20/09/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|wrong test procedure used|object types to eng matl class|scm|engineering|engineering error|Test requirement in TR1233|GAP towards Contract req. identified
ZF|P6000042969|26/08/2010|priority 1 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|test|missed operation|scm|scm|test|incorrect set up testing|Error during pressure test.|Operator error  Vendor are informed
ZF|P6000147859|13/11/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|undertorqued|hydraulic products|other hydraulic products|assy|operator error|Leakage from C1 R 2 port- Man. block|Plug itself was only hand tighten
ZF|P7000000897|14/09/2011|priority 3 |Q3|SHELL|unknown info region|NOPT NOTE NOCO ATCO|marking|marking not readable|ss compl. & w.over xt general|tree assembly|other causes damage|no noncompliance|Marcação ilegível|NÃO HÁ NÃO CONFORMIDADE
ZF|100067526|28/11/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|other causes damage|no noncompliance|Missing HFT for SCM PN 100067526|HFT OMM-0011272 is linked in SAP
ZF|100025661|08/08/2005|priority 3 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|vendor|component error|INTERNAL PT OUT OF RANGE|INTERNAL PT OUT OF RANGE
ZF|P6000108984|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|7102643|11/09/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly test|documentation general|scm hydraulic|other scm hydraulic|engineering|material master dbi error|Not conformity between drawing and BOM|Unknown
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|electrical|rcm electronics|defect locations onshore|montasje|initial direct product problem|material|GFS SCM 08  Bytting av trykktrandsusere|unknown info root_cause
ZF|7102969|25/03/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|drawing error|scm|scm|engineering|engineering error|Updates of Drawings for MEGI SCM|O-ring was missing on DWG and BOM
ZF|100020562|19/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|marking|marking content error|scm|scm|intercompany|kongsberg|Wrong MWP on SCM Nameplate|Incorrect marking on nameplate
ZB|100036936|31/05/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|physical|scm|scm|other causes damage|damage from wear and tear|Urd  SCM  silicon lekkasje|leakage ion the hose connecti
ZF|100037967|22/01/2008|priority 1 |Q3|BP|unknown info region|NOTE NOCO NOPT|assembly test|function|scm|scm|assy|unknown info cause_desc|SEM A FAILURE ON MCM S3|unknown info root_cause
ZF|100036232|17/11/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|physical damage|scm el opt components|other el opt components|assy|missing operation|Cust Dev Crack on Cap|unknown info root_cause
ZF|100031223|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|P7000000897|26/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|component traceabilitynot maintained|fks quality system issues|measuring analysis & improvement|materials stores|lack of training|Item sem Set Out|Item sem set out
ZF|P6000043122|16/10/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|unknown info damage_desc|topside products|n a sw|engineering|unknown info cause_desc|ESS config file must be updated|unknown info root_cause
ZF|P7000024191|11/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|scm|scm|qa qs qi|operator error|TESTE HIPERBÁRICO|unknown info root_cause
ZF|7102969|26/05/2005|priority 3 |Q3|EXXONMOBIL|unknown info region|ATCO NOTE NOPT NOCO|damage|damage during testing|scm|scm|other causes|do not use|SCM OVER PRESSURE|LP hyd. over pressured during testing
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000105542|09/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|conversion approval|scm|scm|fabrication shop personnel|operator error|NCR-Deviation from “no dead end” princip|unknown info root_cause
ZF|100030542|18/03/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOTE NOPT NOCO|documentation|incorrect user documentation (customer)|sensors|scm flowmeter|engineering|engineering error|COM test on SCM 23|Wrong accept. criteria in PRD-0000022442
ZF|100054943|25/01/2008|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOPT NOCO|documentation|missing certificates records|scm|scm|other causes|no noncompliance|missing batch numbers|change to batch management
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|assembly test|do not use|fks quality system issues|resource management|assy|missing operation|Not performed HFT do to lack of time|PSM not followed  short mob time
ZF|100025661|19/02/2004|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly test|cleanliness|scm hydraulic|accumulators|vendor|assembly error|ACCUMULATOR IS NOT FLUSHED|Contamination
ZF|100048038|24/01/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|NOCO NOPT NOTE ATCO|damage|damage during assembly|scm|scm|vendor audit|unknown info cause_desc|Scratches on the base plate.|damaged during movement in workshop
ZF|P6000069820|22/03/2011|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOTE NOCO NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Cleaning Sequence Table is wrong|Cleaning Sequence Table is wrong
ZF|P7000020444|26/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|raw material|defects in material|scm sem el opt component|optical penetrator (insert)|vendor|equipment malfunction|Fiber penetrator damaged|Arrived Damaged from ODI
ZF|P6000058949|07/09/2010|priority 1 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|test|leakage (fluid)|scm|scm|engineering|engineering error|leaking on test|Incorrect screw quality used in BOM
ZF|P6000079433|12/10/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE NOCO NOPT ATCO|documentation|incorrect certificates records|scm|scm|engineering|procedure error|Flushing procedure is wrong|Sequence in flushing procedure wrong
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #6 Wiring|BPTH SKOFLO SCM SN #6 Wiring
ZF|P6000100953|10/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm|scm|test|incorrect set up testing|Measured 0Volt on EC1 pin 9 and 10|Operator error (wrong connection on EC)
ZF|P7000001843|26/06/2018|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|machining|thread error|object types to eng matl class|scm|machining|incorrect tool|MMR - Broken Screw on Base Plate|Incorrect Tool
ZF|100025661|04/10/2005|priority 3 |Q3|SHELL|GOM|NOCO ATCO NOTE NOPT|design|user documentation procedures|scm|scm|vendor|vendor design error|HFT DOCUMENT DISCREPENCY|HFT DOCUMENT DISCREPANCY
ZF|100049000|13/04/2012|priority 2 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|test|wrong test procedure used|scm|scm|test|incorrect set up testing|SCM 23  Visual inspection / Seal inspect|SCM 23 Wrong pressure test performed
ZF|P7000020444|29/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|Flowmeter Não Conforme|Flow technology
ZF|P6000065886|27/12/2010|priority 2 |Q3|ENI|NORTH SEA|NOTE ATCO NOCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000088614|27/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|drawing error|scm|scm|engineering|dwg error|The DU are not the same|Drawings updated to reflect each other
ZF|P6000079032|05/06/2012|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO|test|function|scm|scm|other causes damage|cause not found|PSD B card selftest fails on DO#5 Core 1|Follow-up in QN200279946
ZF|100037967|15/03/2006|priority 1 |Q3|BP|unknown info region|NOCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other causes|qn cancelled|Some drops of water in silicon sample|cancelled QN
ZB|7101172|11/10/2005|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|raw material|defects in material|scm|scm|manufacturing|do not use|AI card at SEM B at SCM is not working|AI card might be of batch with failure
ZF|P7000016420|02/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|cleanliness|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Interior de Manifold Block com cavacos|Bosch - manifold block c/ cavacos
ZF|100035400|16/01/2006|priority 3 |Q3|LLOG|unknown info region|ATCO NOTE NOPT NOCO|design|user documentation procedures|scm|scm|vendor audit|unknown info cause_desc|FAILURE TO OPPERATE TO HFT REQUIREMENTS|HFT DOCUMENT ERROR
Q3|7101172|17/03/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|electrical|printed circuit board|defect locations offshore field|gullfaks a|initial direct product problem|function|GFS SCM 06  Down hole pressure gauge.|Smedvig supplied DHG at fault
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte av solonoider på ventiler.|unknown info root_cause
Q3|7100320|06/07/2000|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOPT NOTI NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM 19|Wrong materials
ZF|P6000077632|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000016420|30/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|interface issue|scm hyd mech components|locking mechanism|vendor|damage during transport|Extension Rod / P55-09|UVDAL
ZF|100020562|14/10/2010|priority 1 |Q3|BP|GOM|NOCO NOTE|documentation|missing certificates records|scm|scm|projects|documentation error|BPTH SCM 28-need to determine SW|Documentation wasn't correct.
ZF|P7000001621|15/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|imension (tolerance)|scm|scm|engineering|specification error|Comprimento de rosca insuficiente.|unknown info root_cause
ZC|100046112|05/07/2012|priority 2 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|scm|scm|engineering|continuous improvement|Angel SESI not comply with testing docs|Error in procedures is updated.
ZF|P6000068924|27/01/2012|priority 3 |Q3|TOTAL|unknown info region|NOPT NOCO NOTE ATCO|test|function|scm|scm|vendor|material error|Current reading is outside accept crit.|Corrected by SW-calibration
ZF|100029062|11/04/2011|priority 1 |Q3|TOTAL|unknown info region|NOTE NOCO|other defect|functional|electronic boards|dhi|vendor|equipment malfunction|Down Hole Gauge testing failure with SCM|unknown info root_cause
ZB|P6000105542|21/01/2016|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|function|scm|scm|other external causes|customer error responsibility|Gullfaks GSO claim 297 SEM Bnocom SUBSEA|Accepted to close SCM subsea
ZF|P7000039672|09/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|other defect|part lost|scm el opt components|el. connector|vendor|missing parts|Missing screws in ODI Connector|1021 - Teledyne Oil and Gas
ZF|100030542|18/02/2008|priority 2 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOPT NOTE NOCO ATCO|documentation|incorrect user documentation (customer)|sensors|scm flowmeter|engineering|engineering error|COM test on SCM 22|Wrong accept. criteria in PRD-0000022442
ZF|100020562|24/04/2010|priority 2 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|cause not found|SCM not functioning properly|SCM  not functioning properly
ZB|P6000042968|02/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO NOTE ATCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 09|Software improvement/correction
ZF|P6000060453|10/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|design|specification error|scm|sem|engineering|specification error|Software  - function removed|Error in Communication Data Allocation
ZF|100052701|11/05/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|other defect|part lost|scm|scm|machine shop personnel|lack of training|Tyr F&D 12 LAck of nitrogen in SCM|unknown info root_cause
ZF|100035118|08/08/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|design|user documentation procedures|scm|scm|other causes|do not use|SCM|Documentation not distributed.
Q3|7101172|29/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|mechanical|mechanical components|defect locations offshore field|deepsea trym|initial direct product problem|damages|Check valve damaged when installed on XT|Assembly error after testing in Bergen
Q3|100017305|13/11/2002|priority 3 |Q3|STATOIL|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|design specification error|Sølvbelagte skruer (silver platted screw|Wrong screw used for SCM
Q1|100018820|28/01/2003|priority 3 |Q1|EXXONMOBIL|NORTH SEA|NOCO NOPT ATCO NOTE|scm rcm|scm|defect locations offshore field|sleipner loke|initial direct product problem|function|SIGYN A-1H SCM#3 status buffer trigged|QN is transferred to SN 300025059
ZF|3794920|10/08/2006|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|procedure error|scm|scm|engineering|engineering error|Errors in SCM FAT procedure|unknown info root_cause
ZF|100034440|12/10/2005|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|material master error|scm|scm|engineering|engineering error|Documents/drawings must be updated|unknown info root_cause
Q3|7105128|09/02/2000|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|mechanical|locking mechanism|defect locations onshore|fks xmas tree fcm workshop|initial direct product problem|function|SCM P 04|Chromate coating. Now changed to Xylan
ZF|100029564|26/08/2004|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other external causes|customer error responsibility|The records from tank test was lost|Computer failure at CBV
ZD|P6000067533|12/07/2011|priority 2 |Q2|KIRINSKOYE SPS|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|engineering error|Error in ELD60060320 for Kirinskoy.|Forgot to evaluate wiringdiagram changes
ZF|P6000068770|23/09/2011|priority 2 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO|design|dbi error|scm hyd mech components|outer can|engineering|dbi error|Outer-can mech BOM in SAP is incorrect.|Engineering error. LST and PN corrected
ZF|P6000042969|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|NOPT NOTE NOCO ATCO|assembly|assembled incorrectly|scm|sem|engineering|specification error|SCM to be upgraded acc. to DRM60046044/A|Designe error
Q3|7101172|30/08/2000|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTI|hydraulic|hydraulic control valves|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM LP hyd leak on well H-2H  (1.2L/hr)|Control valve leaking
Q3|7104670|02/02/2001|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|electrical sensor equipment|electrical pin connetors|defect locations onshore|workshop|initial direct product problem|damages|SCM 9 pin Tronic coupl.forced into 12pin|unknown info root_cause
ZF|100017278|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZB|100051269|10/09/2008|priority 4 |Q1|STATOIL|NORTH SEA|ATCO ORAS NOPT NOTE NOCO|other defect|functional|scm|scm|vendor|equipment malfunction| SEM A not working.|Replace SCM
ZF|P6000103208|10/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7104670|12/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations onshore|workshop|initial direct product problem|function|SCM communication probl. v/sem B|unknown info root_cause
ZF|7102969|01/03/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly test|function|scm|scm|vendor|component error|bad internal PT|Defective Internal PT
ZB|100030542|11/10/2005|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly test|do not use|scm|scm|assy|operator error|SCM Flushing with wrong fluid|Procedure not followed.
ZF|100059660|05/11/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|drawing error|scm|scm|engineering|dwg error|Drawing document wrong|SEM brackets drawing wrong engineered
ZD|P6000064909|07/03/2012|priority 1 |Q2|TOTAL|NORTH SEA|NOCO ATCO NOTE|change deviation request|conversion approval|scm|scm|intercompany|kongsberg|SCM Change Hydraulic Fluid|SCM shipped to be reflushed
ZF|P6000110991|22/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|drawing error|scm|scm|engineering|dwg error|Missing earthstraps on EC's baseplate|Missing earth connection towards ECs
ZF|P7000039672|02/04/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|assy|operator error|Rosca de adapter plate danificada|unknown info root_cause
ZF|100048038|16/02/2006|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly test|interface of components issue|scm|scm|assy|missing operation|PIPE IS IN TOUCH WITH THE EL. BRACKET.|pipe route is too close to SEM bracket
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOPT NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Missing rubber prot.inside comp. chamber|unknown info root_cause
ZF|P7000001843|23/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|test omitted|scm|sem|assy|operator error|Teste não realizado|unknown info root_cause
ZF|P6000100953|10/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|computer system software|sem tpu config|engineering|procedure error|Wrong in new Config|unknown info root_cause
ZF|3794920|16/06/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|hydraulic valves|vendor audit|unknown info cause_desc|Internal leakage test outside criteria|leakage accepted at 0.21ml
ZF|100036936|22/11/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|assembly test|missed operationassy test|scm|scm|other external causes|customer error responsibility|HFT not performed|Due to lack of time
Q3|7105597|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|documentation|Wrong basic data|unknown info root_cause
ZF|P6000028371|18/10/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|coating|coating defects|sensors|scm pressure transmitter (pt)|vendor|fabrication error|airpockets in glue|Material err.  No impact on function
ZD|100020562|01/03/2007|priority 1 |Q2|BP|GOM|NOCO ATCO NOPT NOTE|assembly test|function|scm|scm|vendor|component error|SCM INTERNAL PT'S FAILED|Insufficient cleaning during man.
ZF|P6000088614|26/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000042968|26/02/2009|priority 1 |Q3|TOTAL|WEST AFRICA|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|scm|sem|engineering|specification error|SCM to be upgraded acc. to DRM60046044/A|Designe error
ZF|P6000058949|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|DWG error
ZF|P7000039672|13/11/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|vendor|equipment malfunction|Restrição na Linha do SCM|unknown info root_cause
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7103234|15/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|function|Install hydaulic flow restrictors|unknown info root_cause
ZF|P6000069056|23/01/2012|priority 3 |Q3|HYME PROJECT|unknown info region|ATCO NOCO NOPT NOTE|design|drawing error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Insufficient wall thickness in m. block|Ref. QN 200241870
ZF|P6000093498|11/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|electronic boards|other eletronic boards|vendor|equipment malfunction|"SMU card entering ""System Error"""|Board failure  followed up in ZF QN
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
Q1|7105129|15/08/2002|priority 2 |Q1|TOTAL|unknown info region|NOPT NOCO NOTI|mechanical|el.can bracket|ext. loc. luanda (angola)|work shop|initial direct product problem|leakage|SCM 02 GIR SEM A malf(silicon in el-can)|Silicon in el.can
Q3|7100320|17/02/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Skifte solenoider ventiler sn. 16|unknown info root_cause
ZF|P6000116166|27/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|electric products|electrical connector|assy|damaged during assembly|Screw got stuck|Screw got stuck during assembly
Q3|3794920|19/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|quality system issues|kos quality system issue|defect locations onshore|workshop other|initial direct product problem|documentation|SSP SCMs 28  42  44: various punches|unknown info root_cause
ZF|P6000064910|27/12/2010|priority 2 |Q3|TOTAL|NORTH SEA|NOPT NOCO ATCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Wrong type of screws used on valves
ZF|7101401|03/06/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOTE NOCO|damage|damage due to handling|scm hyd mech components|hydraulic manifold adapter plate|service :|damaged during installation|MMR - Couplers external leakage|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000069820|04/07/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE NOCO|test|missed operation|scm|scm|other causes damage|qn cancelled|incorrect rev of procedure is used|Ref QN: 200213490.
ZF|P6000063531|01/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|component traceabilitynot maintained|scm hyd mech components|control valve|intercompany|kongsberg|Wrong S/n on one valve in the i basa|Ibase list wrong acc to physical s\n
ZF|100049392|13/07/2006|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly test|interface of components issue|scm|scm|other external causes|customer error responsibility|3162F&34 - no SCM to XT base plate fit|Wear and tear
ZF|100035118|15/10/2004|priority 2 |Q3|WOODSIDE|unknown info region|ATCO NOCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|outer can|assembly test|operator error|WATER IN THE SILICON SAMPLE|Test equipment damaged during test.
ZF|100037967|06/03/2006|priority 1 |Q3|BP|unknown info region|NOTE NOCO ATCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|assy|operator error|Water detected in SCM after Hyperbaric|Drain plug not tightened
Q3|100016901|24/07/2002|priority unknown info priority|Q3|BP|GOM|NOPT NOTI NOCO ATCO|hydraulic|hydraulic control valves|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause assembly test|workshopassembly test error|Leakage between CV and Man. Block|Leakage
Q3|7103233|01/12/2000|priority 4 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|ATCO NOCO NOPT NOTI|electrical|pressure transducer|defect locations onshore|workshop other|root cause vendor|design error|SCM returned for upgrading of PTs|unknown info root_cause
ZF|100046112|17/11/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|design|do not use|fks quality system issues|product realization|other causes|no noncompliance|Implementation and test of Fast Scan|QN established to manage tasks
ZE|P6000069820|25/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm sem el opt component|other scm sem el opt components|variance|capture mistake|COPI Platform Comms Startup Shutdown|Unable to establish communication
ZF|P6000063531|15/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm el opt components|scm wiring|machine shop personnel|operator error|Incorrectly connected 0V wire EC 3 plug|Human error. Wires connected wrong
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE NOPT NOCO ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 09|Software improvement/correction
ZF|P7000039672|06/04/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|damage|damage during testing|object types to eng matl class|scm|other causes damage|cause not found|Conexão grimpada|unknown info root_cause
ZE|P6000103208|17/10/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|electrical|design error|(E) - SCM power supply and smoke issues|unknown info root_cause
ZF|P7000039672|20/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|functional|electronic boards|other eletronic boards|engineering|continuous improvement|Atualização do modem MRM das Eletrônicas|unknown info root_cause
ZB|100020562|30/07/2008|priority 3 |Q1|BP|GOM|NOPT NOTE NOCO|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|Erratic pressure readings.|Erratic pressure readings.
ZF|P6000042969|13/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly|interface issue|scm|scm|assy|operator error|red hydraulic dust caps left on XT|Red protector Caps lef on SCMMB
Q3|7100320|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 03|unknown info root_cause
ZF|100017278|04/12/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|damage|wear & tear|scm|scm|other causes damage|unknown info cause_desc|Error on L-4H  - SCM - SEM B|Falt on SEM B
ZF|P7000008275|01/06/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|scm|scm|test|damaged during testing|Assinatura de válvulas SCM 06 TBU|defeito durante o teste
ZF|P6000103208|09/07/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000138867|18/05/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|marking|marking content error|scm hyd mech components|other mechanical components|marking|incorrect marking|SCM  Wrong on MAC adress plate|Wron MAC address on name plate.
ZF|P6000028371|06/05/2008|priority 1 |Q3|SHELL|GOM|NOCO NOPT NOTE|test|function|sensors|flowmeter|vendor|programmer error|MPFM are not working properly on SEM B|Mismatch dual Core PC and MPFM program
ZB|100001156|07/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTE|test|leakage (fluid)|scm|scm|other causes damage|unknown info cause_desc|Guarantee claim 107 - Comm.failure SEM B|Too high leakage rate at COV
ZF|P7000016420|13/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|electronic boards|comm.link (power line)|engineering|specification error|Problema de comunicação com a placa TIF|Software
Q3|3812476|08/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTI|scm rcm|scm|defect locations offshore field|norne fpso|initial direct product problem|function|SCM  PMV doesn't open with SEM A|Not known
Q3|7101172|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|Feil og mangler i prosedyre Gfs/Åsg.|unknown info root_cause
ZF|100052701|15/04/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|marking|marking content error|scm|scm|materials stores|operator error|batch numbers missing|unknown info root_cause
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|scm rcm|scm|defect locations offshore field|shell alliance gom|root cause vendor|assembly fabrication test error|Shell SCM Communication problem|Vendor changed colors on wires
ZE|P6000042968|11/03/2010|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|topside products|n a sw|causes for improvement|documentation|DHI error message received in ST report|Documentation
ZF|P6000042968|19/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|project|project requested unfinished shipment|scm|scm|engineering|procedure error|Material not delivered to plant|FMC Engineering : Process error
ZB|100001156|20/09/2005|priority 4 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|assembly test|function|sensors|scm pressure transmitter (pt)|machine shop|tooling|Failure on pressure indicator in new SCM|A sensor is not functioning acc.
ZF|P6000104113|19/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|engineering|engineering error|Update KS200e SW for Egina|Com. functionality which was not cons.
Q1|3801623|02/10/2000|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|mechanical|outer can|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause assembly test|workshopassembly test error|SCM anodes mounted wrong|Assembly error
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Not performed HFT do to lack of time|unknown info root_cause
ZD|100036936|01/08/2005|priority 3 |Q2|STATOIL|NORTH SEA|NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|WASHERS FOR ISOLATION PLUGS ARE LOOSE|unknown info root_cause
ZB|P6000064911|10/06/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|electrical|performance|fks quality system issues|quality management system|electrical|other specify in comments|Defect Not. 08 - SRM A Tormore|cause unknown - no liabiliy for FMC
ZF|P6000064909|24/05/2011|priority 2 |Q3|TOTAL|unknown info region|NOTE ATCO NOCO|design|drawing error|scm|scm|engineering|dwg error|position on orientation pins EC`s outerc|DWG error(Pos of orientation pins on EC)
ZF|P6000069820|04/07/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOCO NOTE|test|missed operation|scm|scm|other causes damage|qn cancelled|incorrect rev of procedure is used|Ref QN: 200213490.
ZF|P7000001621|10/03/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|physical|scm|scm|other external causes|customer error responsibility|Agua no Conector de Base|SCM Removal from hydrated slot
ZE|100035118|11/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|intercompany|kongsberg|WEL  Test Failure  L1 Escape|unknown info root_cause
ZF|P6000063531|29/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|missed operation|scm|scm|test|tooling|Acoustic Leak Detector test in HFT|Lack of functional CPI test equipment
ZF|P6000098616|12/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|missed operation|scm|scm|assy|operator error|Silicone drainport loose.|Drain port not torqued  see RCA.
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO DLFL|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000024900|14/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|missed operation|scm|scm|other external causes|customer error responsibility|BC-10 SN 22 phase 2.|Shell need the SCM without some tests.
ZD|100020562|26/11/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|coating plating|incorrect colour coating|scm hyd mech components|outer can|paintshop|operator error|Outer can stripes|unknown info root_cause
ZF|P6000100953|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 14|Software improvement/correction
ZB|100049000|22/05/2009|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|damage|unknown info damage_desc|scm|scm|vendor|material error|DHFC SCM 04 RAM Warning|Defective RAM chip
Q3|7102643|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|hydraulic|hydraulic control valves|defect locations onshore|montasje|initial direct product problem|function|HC17/18 valves changed place.|unknown info root_cause
Q3|3794920|unknown info defect_date|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|electrical sensor equipment|electrical pin connetors|defect locations offshore field|sleipner loke|initial direct product problem|function|Elect. fault occured when landing SCM|Pin conn. damaged (possibly offshore)
ZF|P7000001621|02/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|physical damage|scm hyd mech components|baseplate|service :|damaged during installation|Base Plate - Morsas|Impacto lateral no pino guia.
ZF|100020278|01/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|wrong part assembled|scm|scm|vendor|assembly error|Pin not fit|Change pin to smaller one which fits
ZF|100035118|19/03/2007|priority 3 |Q3|WOODSIDE|unknown info region|NOCO ATCO NOTE NOPT|damage|wear & tear|scm|scm|vendor audit|unknown info cause_desc|Locking mechanism needs refurbishment|Line missing in prosedure
ZF|P6000058949|17/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|scm|scm|other causes damage|qn cancelled|PT results fluctuate running on SEM A|Short circuit in LP FM.  ref QN200200560
ZF|P6000104112|18/01/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|wrong test procedure used|scm|scm|other causes damage|cause not found|SCMs Fliud Issue for WI XTs|unknown info root_cause
ZF|P7000001621|27/08/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|coating plating|painting defect|ss compl. & w.over xt general|horizontal penetrators|paintshop|operator error|camada de pintura fora do especificado|Camada de revestimento acima
ZF|P6000074156|06/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|05/09/2018|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|dbi error|object types to eng matl class|kits|engineering|ecn change|ECN  7090703    PN  P7000017838|Error-concept/calculation
ZF|P6000068924|21/12/2012|priority 2 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE|test|function|scm sem el opt component|other scm sem el opt components|assy|operator error|MMRSRM Clov 7 Fiber Connection|Bad welding on fiber in SCM outher can
ZB|100020562|26/08/2009|priority 3 |Q1|BP|GOM|NOTE ATCO NOPT NOCO|test|function|scm electrical|pressure transducers|other causes damage|damage from wear and tear|No Pressure reading on PT2|No Pressure reading on PT2
ZF|P6000116166|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|100015314|09/08/2010|priority 3 |Q3|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|unknown info region|NOPT NOTE ATCO NOCO|test|cleanliness|scm|scm|other causes damage|damage from wear and tear|Contamination found in SCM silicone oil|Burst bladder due to long time storage
ZF|P6000068902|04/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|design|dbi error|scm el opt components|trafo unit|other causes damage|qn cancelled|no traceability on trafo parts|All parts recorded correctly.
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|NOPT NOCO ATCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
Q3|3812476|27/12/1999|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations offshore field|transocean prospect|initial direct product problem|leakage|Internal hydraulic leak in SCM|Hyd leak in SCM CVs/cause not known
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|scm|scm|other causes damage|cause not found|08-MEGI-018: RAM Warning Error|Error Message
ZB|7104670|16/03/2006|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other external causes|customer error responsibility|Leak in SCM on HXT|The module have not been refurb.
ZF|100037428|15/06/2012|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOTE|other defect|part lost|hydraulic products|relief valve|materials stores|improper packaging & storage| Check valve found missing (SCM)|unknown info root_cause
ZB|P7000002082|12/06/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOPR NOTI OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|FNCR 2604 - SCM SN-03 Plangas - AI Board|unknown info root_cause
ZF|P7000000897|06/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|assy|damaged during assembly|coupler vazando.|unknown info root_cause
ZF|100052701|06/03/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|batch on nuts and bolt missing|change to batch management
ZF|100050519|04/10/2006|priority 3 |Q3|TOTAL|unknown info region|NOCO ATCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other causes|no noncompliance|Leakage  Hydraulic|leak measurements compromised by CHKV
Q3|7100320|17/12/2001|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|leakage|SCM 19 Hercules CVLP/AI board failure|unknown info root_cause
ZE|P6000074156|02/07/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm|scm|causes for improvement|process procedure ineffective|Found silicone leaking out from SCM|Silicone leaking
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|Discoloured outercan black lines|Paint lines faded after hyperbaric
ZF|100006609|19/04/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|scm hyd mech components|sem can|purchasing|purchasing error|Furações fora de centro.|unknown info root_cause
Q3|100020562|11/10/2002|priority 2 |Q3|BP|GOM|ATCO NOPT NOTI NOCO|scm rcm|scm|ext. loc. kos houston|work shop|root cause engineering|delivered parts not acc. to bom spec.|Faults on SCM delivered to Houston|FKS design errors
Q3|7102643|09/11/1999|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|AWV PT no indication on both SEMs (R1-H)|Internal short circuit on PLFS160  SEMA
Q3|7104670|21/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|hydraulic|chemical control valves|defect locations offshore field|heidrun tlp|initial direct product problem|function|Suspect CIDV is clogged  well D-2H|Contaminated  refer to QN200007024
ZF|100058509|10/11/2009|priority 2 |Q3|LLOG|unknown info region|ATCO NOPT NOCO NOTE|coating plating|incorrect colour coating|scm|scm|vendor|specification not followed|Bad paint jobb outercan|Bad Paint job and dirty Outercan
ZF|P7000016420|30/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|scm hyd mech components|locking mechanism|vendor|damage during transport|Extension Rod / P55-09|UVDAL
ZF|P6000067533|04/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|PT doesn't show values|Incorrect wiring of PT
ZF|P7000039672|01/10/2018|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|dbi error|object types to eng matl class|clamps_common|engineering|ecn change|ECN 7090703 -  P7000039672 - PRE SAL|CHANGE OF ITEMS 6 AND 10 FROM DBI.
Q3|7101401|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|mechanical|hydraulic manifold block|defect locations onshore|workshop other|initial direct product problem|material|Replace Marlim SCM lee Plugs|Wrong material
ZF|P6000121268|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|P6000079032|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTE|design|drawing error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Insufficient wall thickness in m. block|Ref. QN 200241870
ZF|P7000001843|21/11/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|welding|structural nde defect|scm|scm|other causes damage|cause not found| -R.N.:|unknown info root_cause
Q1|7103233|22/04/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Accumulator N2 fitting different type|unknown info root_cause
ZF|100037427|12/07/2018|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|missed operation|scm|scm|other external causes|customer error responsibility|CTR 513 Mob Rejected by COMPANY|procedure not followed at client request
ZF|100048038|31/03/2007|priority 2 |Q3|CHEVRON|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 26|Damage in warehouse handling
ZF|P6000055605|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000024191|02/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|engineering|procedure error|Vazão não atendida nno Flushing|Erro no procedimento
ZD|100048038|21/03/2007|priority 3 |Q2|CHEVRON|WEST AFRICA|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|assy|missing operation|SEM INTERNAL PRESSURE SENSOR|Defective connector against PTR150 board
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTI|hydraulic|hydraulic control valves|defect locations offshore field|shell alliance gom|initial direct product problem|leakage|'Choke open' control valve malfunction|control valve seat wear
Q3|7103479|06/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|hydraulic|hydraulic control valves|defect locations onshore|fks adm.|initial direct product problem|leakage|LP hydraulic leak of 600 litres/day|Control valve leaking
ZF|P6000069056|29/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|marking|marking content error|scm|scm|assy|operator error|Mismatch between GA and TDI|Name plate not marked acc to GA
ZB|7104670|24/04/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|test|operator error|GC 262 hydraulic fault (Statoil Heidrun)|Operator Error
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|process procedure ineffective|CAR 7 RCA Actions_2 from RPT10033107|unknown info root_cause
ZD|P6000147469|19/12/2017|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO|certification|not available|object types to eng matl class|scm_assy|documentation requirement|missing|Certs issue|unknown info root_cause
ZF|P6000060453|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|other defect|functional|fks quality system issues|quality management system|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|P6000080733|05/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|missed operation|instrumentation|other scm instruments|test|missed operation|Unable to perform test according HFT|DHI not configurated toward simulator
ZF|100056176|31/10/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|project|project requested unfinished shipment|customer compliant|noncompliance to customer requirement|assy|operator error|SCM recived in workshop un washed.|unknown info root_cause
ZF|P7000008275|09/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm|scm|other causes damage|damage from wear and tear|Teste hiperbárico|Não estabilização de pressão
Q3|7104033|07/12/1999|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|hydraulic|accumulators|defect locations offshore field|statfjord c|root cause engineering|design specification error|Hyd press. drop during valve operations|Need hyd flow restrictors
ZF|100017278|14/12/2005|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM  57 ÅSG DHI109 switch wiring to conn|unknown info root_cause
ZF|P6000055198|22/02/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|specification error|scm|sem|engineering|engineering error|Power-control DHI 118 is not working|unknown info root_cause
ZF|P7000039672|29/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|wrong part assembled|scm el opt components|el. connector|vendor|wrong part delivered|Incorrect diameter of o-ring|PO 47627521-6 - Teledyne Oil & Gas
ZF|100038200|27/02/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|user documentation procedures|scm|scm|vendor|fabrication error|HFT 0000021252 is completely incorrect|HFT Doc. Not Correct
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
ZF|100037428|06/06/2007|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|assembly test|assembled incorrectly|ss compl. & w.over xt general|tree assembly|assy|operator error|Rosa XT P9 with missing parts|unknown info root_cause
ZF|100059660|07/07/2010|priority 4 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|design|specification error|scm sem el opt component|other scm sem el opt components|engineering|specification error|B&B07 DHPG malf. during flowing of well|DHPG malfunction
ZB|100031223|28/10/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|functional|scm|scm|other causes damage|cause not found|GC 268-SCM Comm. probl.|unknown info root_cause
ZE|100017278|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|electronic boards|other eletronic boards|causes for improvement|process procedure not being followed|Misguiding information in PRD-0000024365|Procedure updated
ZF|100035118|30/09/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOCO ATCO NOTE NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|engineering|dwg error|Silicone Compensator burst.|Marginal design.
ZF|100030542|01/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|wear & tear|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|Wear and tear.
ZB|100067526|02/02/2016|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|engineering|specification error|GC 175371 Leakage SCM (Statoil Gullfaks)|Missing references in specification
ZF|100029564|20/06/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|assembly test|documentation general|scm electrical|other scm electrical|engineering|design specification drawing error|FAIL WITH BOM|Design fault
Q3|7102643|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|electrical|modems communications|defect locations offshore field|åsgard a|initial direct product problem|function|Communication problems with SEM A|Comms established/no fault found
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
ZF|P7000024191|16/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|interface issue|scm hyd mech components|check valve|other causes damage|cause not found|Check Valve não conforme.|Sem evidência da causa
ZF|P6000069056|02/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|leakage (fluid)|scm|scm|test|operator error|Missing HC61 on hyberbaric camber 3|Forgot to close valve on test panel
ZE|P7000000897|19/10/2016|priority 1 |Q3|SHELL|unknown info region|ATCO NOTE NOCO|test|function|scm hyd mech components|control valve|assembly|improperly installed|MMR - Change Over HP with reversed link|Wire labels installed incorrectly.
Q3|3812476|05/04/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|lifting|SCM 18 damaged due to lifting method|Correct lifting method was not used
ZF|P7000039672|23/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|component error|scm sem el opt component|other scm sem el opt components|intercompany|kongsberg|Short-Circuit wires 261-262|unknown info root_cause
ZF|P7000016420|13/04/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|function|scm|scm|test|incorrect set up testing|Teste Long term não conforme.|set up com defeito.
ZE|P6000103208|19/09/2016|priority 3 |Q3|EXXONMOBIL|GOM|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|test|incorrect setup|SCMDT  Julia #05  SEM short circuit|Damaged during test. See RPT60139427
ZF|7100320|24/11/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MMR - Mech. Interference of Grooved Pin|unknown info root_cause
ZF|P6000069056|29/09/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring on PT 61A  Signal Crossed|Wrong wiring against PT61  switched pair
ZF|100018531|19/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|marking|marking content error|scm|scm|engineering|dwg error|Divergências Desenhos|unknown info root_cause
ZF|100020562|02/08/2010|priority 3 |Q3|BP|GOM|NOTE NOCO NOPT|marking|no marking|scm|scm|other causes damage|cause not found|Mark all necessary ports on BPTH SCMs|unknown info root_cause
ZF|7105597|06/07/2010|priority 3 |Q3|PETRO SA  MOSSEL BAY|unknown info region|NOCO NOTE NOPT|test|cleanliness|scm|scm|test|damaged during testing|Crude oil in the return system|To be followed up with reason  SO1091305
Q1|7102643|13/10/2000|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|scm rcm|scm|defect locations offshore field|scarabeo|initial direct product problem|function|Water from HXT umb. jumper MQC plate L16|No fault found
Q3|7101172|23/11/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM upgrades after removal of outer can|unknown info root_cause
ZF|P6000029772|07/09/2009|priority 3 |Q3|ENGIE|NORTH SEA|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Fiber is twisted|Wrong assembling of optic fiber
Q3|100018082|08/07/2002|priority unknown info priority|Q3|STATOIL|NORTH SEA|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|efat|root cause vendor|material component error|PT 32 AND 16 DEVIATE 15 BAR FROM ACTUAL|unknown info root_cause
ZF|P6000093498|04/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|cleanliness|scm|scm|assy|damaged during assembly|Water in Silicone sample|SCM filled with contaminated silicone
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOCO NOPT NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PT adapter plate is loose|unknown info root_cause
Q3|7102643|25/02/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|mechanical|hydraulic manifold block|defect locations onshore|workshop other|initial direct product problem|documentation|Åsg SCM 36  press. tested for only 14min|Test print out shows 14 mins duration
ZF|P7000024900|07/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|cleanliness|scm|scm|other causes damage|cause not found|Fluido durante a coleta de silicone|unknown info root_cause
ZF|100056443|14/03/2011|priority 1 |Q3|EDISON/EDF|NORTH SEA|NOTE NOCO|test|cleanliness|scm|scm|test|incorrect set up testing|Pollution to Braico on EHXT and SCM.|Incorrect set up/testing
ZF|P6000077632|01/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|documentation|missing user documentation (customer)|scm|scm|engineering|continuous improvement|No Xt-SCM test procedure for 615 SCMs|unknown info root_cause
ZB|P6000088604|12/08/2015|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|physical damage|customer compliant|noncompliance to customer requirement|test|tooling|XT#06 SCM ACCUMULATOR LEAKAGE|ACCUMULATOR N2 LEAK DURING TEST AT SS
ZF|P6000116166|27/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|interface issue|electric products|electrical connector|vendor|assembly error|Screw got stuck|Screw got stuck in threads
ZF|100067526|17/01/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|dimension (tolerance)|scm hyd mech components|accumulator|vendor|assembly error|External accumulator not within acceptan|Gap between oil port and bottom plug
ZF|P6000062454|08/09/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|documentation|procedure process error|computer system software|sem tpu config|engineering|continuous improvement|Config not released  Test files missing|unknown info root_cause
ZF|P6000088604|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000079433|01/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|test|function|scm hyd mech components|check valve|test|damaged during testing|LP return on SCM|Contamination inside check valve
ZF|P6000121268|17/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|specification not followed|Leakage test outside criteria on FAT|DCV leakage
ZF|7104033|05/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|design|drawing error|scm|scm|other causes damage|cause not found|Incomplete GA DWG for SCM PN 7104033|Incomplete GA DWG for Sygna SCM
ZF|P6000064909|24/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|material master error|scm|scm|engineering|engineering error|Incorrect O-ring matnr:200005619|Incorrect O-ring partnr in BOM
ZF|100036936|15/10/2008|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|documentation|procedure process error|scm|scm|engineering|unknown info cause_desc|wireing list mess|unknown info root_cause
ZF|P6000100953|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7102643|21/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|Fault message from SCM SEMA  well Y-4H|SCM reset OK  no fault found
ZF|P6000055605|18/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|documentation|missing certificates records|scm|scm|materials stores|operator error|Part issued without traceability.|Equipment not asigned when picked
ZF|P7000000897|09/09/2011|priority 1 |Q3|SHELL|unknown info region|NOCO NOTE NOPT ATCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|packaging handling|Danos na área de vedação.|UVDAL
ZF|100018082|24/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|test|test omitted|scm|scm|test|incorrect set up testing|not able to perform com test w.sand prob|missing test equipment
ZF|7103233|15/06/2005|priority unknown info priority|Q3|SUNCOR|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|unknown info cause_group_desc|unknown info cause_desc|SIO failure ?|Not yet known (SCM still working subsea)
ZF|100049000|06/12/2005|priority 3 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|hydraulic valves|other causes|do not use|UNSTABLE LEAKAGE ON OPEN AND CLOSE POS.|Inappropriate test equipment.
ZF|P6000055605|16/08/2011|priority 3 |Q3|SHELL|GOM|NOCO NOPT ATCO NOTE|damage|damage during testing|scm|scm|test|damaged during testing|391V on AI input  AI 36 spare 9 is death|Opr. failure  damage by wrong test setup
ZF|P7000000897|07/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|wear & tear|scm|scm|other causes damage|cause not found|Center tube damaged SCM SN:10|Center tube colapsed
ZE|P6000108542|02/02/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|HFT60074760/E has mistake|unknown info root_cause
ZF|100033987|15/11/2006|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|damage|damage during testing|scm|scm|assy|operator error|El. rack applyed to high voltage|Too high op. voltage applied  opr. error
ZF|P7000001621|21/07/2015|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|assembly|physical damage|scm el opt components|other el opt components|assy|damaged during assembly|MMR - PT Broken|unknown info root_cause
ZF|100037965|22/03/2008|priority 1 |Q3|BP|unknown info region|NOCO ATCO NOPT NOTE|damage|wear & tear|scm|scm|other causes damage|cause not found|FPSO NCR 25 - SCM Failure|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000105542|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q1|7105128|12/03/2002|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|girassol fpso|initial direct product problem|function|SCM's  Girassol  DH-gauges malfunction|unknown info root_cause
ZF|P6000057855|24/11/2010|priority 2 |Q3|ENI|unknown info region|NOPT ATCO NOCO NOTE|documentation|procedure process error|computer system software|basis e sw|engineering|procedure error|Software release document is missing|unknown info root_cause
ZF|P7000001621|27/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm hyd mech components|outer can|purchasing|purchasing error|Furações fora de centro|Desalinhamento nas furações
ZF|100031223|02/07/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Missing document links in SAP.|unknown info root_cause
ZF|100054943|09/01/2008|priority 2 |Q3|WOODSIDE|unknown info region|ATCO NOCO NOTE NOPT|documentation|incorrect certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|approved with batch certification
Q3|3794920|27/06/2000|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|hydraulic|hydraulic control valves|defect locations onshore|workshop|initial direct product problem|leakage|Fluid leaking out of flush port (bleed)|SCM tested  no fault found
ZF|100037966|13/04/2008|priority 2 |Q3|BP|unknown info region|NOCO NOTE ORAS ATCO|other defect|functional|scm|scm|other causes damage|cause not found|SCM changeover valve leaking subsea|unknown info root_cause
ZF|P6000058949|18/11/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|marking|marking location error|scm hyd mech components|outer can|engineering|engineering error|Placement of the nameplate in Outer Can|Incorrect positioning of nameplates
ZB|7103234|06/11/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|Warranty Claim for SCM 02I|unknown info root_cause
ZF|P7000024900|06/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|test omitted|scm|scm|engineering|procedure error|MRM test in QAM mode.|unknown info root_cause
ZF|P6000102554|10/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000001621|25/03/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|wrong part assembled|scm|scm|assy|missing operation|Falta de parafuso de fixação no anodo|Itens faltantes
ZF|P6000108542|07/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|instrumentation|scm flowmeter|vendor|equipment malfunction|LP supply flowmeter leakage|External leakage from flowmeter
ZB|100001156|24/08/2007|priority 4 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTE|other defect|functional|scm|sem|other external causes|unknown info cause_desc|SCM6  GFC M-1H  SEMB Comm. failure|Error in DHI board
ZF|P6000105542|09/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTE|assembly|wrong part assembled|scm|scm|engineering|engineering error|NCR to Statoil - SCM manifold block|unknown info root_cause
ZB|P6000055605|02/12/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE NOPT|other defect|functional|scm el opt components|other el opt components|fabrication shop personnel|improper handling|Bonga Claim 002 SCM 320|Incorrect voltage destroyed SEMs
ZF|P6000031350|24/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|electric products|distribution module|other causes damage|planning error|Equipment stored outside|unknown info root_cause
ZF|7104670|25/08/2006|priority 4 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|assembly test|function|sensors|scm pressure transmitter (pt)|assy|missing operation|CIDV supply PT outside accept. criteria.|unknown info root_cause
Q3|7102643|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|product defects for dept.|other|defect locations offshore field|transocean searcher|initial direct product problem|documentation|Computer was not configured for this SCM|No configuration control against Bergen
ZF|P7000039672|24/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|final inspection error|Gland does not fit on Manifold Block|1756 UVDAL MASKINFABRIKK A/S
ZF|P6000067533|08/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|materials stores|improper packaging & storage|SCM Modules stored outside with no PSM|Improper storage
ZB|P6000042969|23/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOCO NOTE|test|test omitted|scm|scm|intercompany|kongsberg|SCM to be tested in a Tree|Shipping delay of SCM
ZF|P6000088604|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000122574|19/08/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|interface issue|scm hyd mech components|other mechanical components|engineering|continuous improvement|PT & valve cover|BOM and drawing with new covers
ZF|P7000024191|04/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|test omitted|scm|scm|test|incorrect set up testing|Man. Global #20 - Can Bus & Serial Line|Lab test box with problem.
ZF|P1000018406|24/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|damage|damage during testing|wocs|installation workover control system (iw|other causes damage|qn cancelled|DHFC will not hold pressure|QN Cancelled
ZF|100015538|18/12/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|test|unknown info damage_desc|scm|scm|test|unknown info cause_desc|HFT on SCM has not been done|HFT not performed
ZF|100006609|17/05/2013|priority 1 |Q3|PETROBRAS|unknown info region|ATCO NOPT NOCO NOTE|assembly|interface issue|scm hyd mech components|outer can|vendor|maintenance|Hose House can't be assembled|SCM MMR
ZF|P6000109194|23/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|specification error|computer system software|sw|engineering|engineering error|4-20mA simulators not working.|unknown info root_cause
ZF|7102969|02/05/2005|priority 3 |Q3|MOBIL EG|unknown info region|NOCO NOTE NOPT ATCO|damage|damage during assembly|scm|scm|other causes|do not use|Parts galling.|Parts galling in assembly
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE NOCO ATCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 08|Software improvement/correction
ZD|100049000|12/02/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|machining|hole size error|scm hyd mech components|outer can|vendor|operator error|Misalignment of the EC bolt holes|unknown info root_cause
ZF|100049392|11/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|test|damaged during testing|Failed tank test/Silicone oil inside SEM|Human error from operator and QA insp.
Q3|3794920|25/06/2002|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|mechanical|mechanical components|defect locations onshore|montasje|root cause other|logisticspacking shipping damage|Repair  ref. SN 30001253|unknown info root_cause
ZF|P7000000229|08/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|hydraulic coupler|vendor|final inspection error|High interference on the coupler thread|1024 - NATIONAL COUPLING CO.  INC.
ZB|P6000055605|14/05/2014|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|functional|scm el opt components|other el opt components|vendor|material error|Shell Perdidio Claim SCM 309|Faulty Line coupler
ZF|P6000074156|09/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|continuous improvement|Serrated lock washer get squeezed|Serrated washers removed from guide pin
ZF|100049000|30/11/2010|priority 2 |Q3|BP|unknown info region|NOTE ATCO NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P6000104116|09/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|machining|surface finish error|scm|scm|vendor|specification not followed|damaged sealing surfaces|Damage on sealing surfaces
Q3|7102643|15/02/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|electrical|pressure transducer|defect locations offshore field|transocean searcher|initial direct product problem|function|PT for PMV not working  well Y3-H|Refer to QN 200006649
ZF|P7000039672|01/09/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|component error|scm sem el opt component|sem cable & wiring|assy|operator error|DHI doesn't communicate|unknown info root_cause
ZF|100036936|08/01/2005|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM NSAT - SW fault for CITV|unknown info root_cause
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|NOPT NOCO NOTE ATCO|assembly test|do not use|scm|sem|vendor|component error|SO due to DC/DC Issue on AI 150 card|Component Failure/Poor Workmanship
ZF|P6000039844|30/03/2009|priority 3 |Q3|SHELL|unknown info region|NOCO NOPT NOTE|test|unknown info damage_desc|scm|scm|engineering|procedure error|24V OUT1 is too low on Sem A|Procedure failure  to narrow  limits
ZF|P6000149536|26/01/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|marking|marking content error|object types to eng matl class|scm_assy|vendor|specification not followed|Talley plate contains wrong data|unknown info root_cause
ZB|100056261|29/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|NOCO NOPT NOTE ATCO|test|function|scm electrical|other scm electrical|assy|damaged during assembly|SEM Common Alarm|SEM Common Alarm
Q3|7100320|31/05/1999|priority 3 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM 14|Wrong materials
Q3|7103233|19/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|function|Install hydaulic flow restrictors|unknown info root_cause
Q3|7101172|05/09/2001|priority unknown info priority|Q3|STATOIL|NORTH SEA|NOPT NOCO NOTI ATCO|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|gullfaks a|initial direct product problem|function|Temp-sensor failure G-3H  GFA|Not yet know  SCM subsea
ZD|100029062|07/10/2010|priority 1 |Q2|TOTAL|unknown info region|ATCO NOCO NOTE|procurement|vendor did not complete required work|scm|scm|intercompany|kongsberg|SCM Issue|Vendor Liability
ZF|P6000074855|13/02/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|specification error|computer system software|sem tpu config|engineering|engineering error|Girry 1 do not appear in ST config|unknown info root_cause
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|hydraulic|hydraulic control valves|defect locations onshore|montasje|initial direct product problem|material|GFS SCM 08  Bytting av solenoider|unknown info root_cause
Q1|7101172|22/04/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM 03 GFA/K-2H SIO scanning failure|unknown info root_cause
Q3|7102643|01/11/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM upgrades after removal of outer can|unknown info root_cause
ZF|100033987|20/08/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|assembly test|documentation general|scm mech w mb|outer can|engineering|design specification drawing error|FAIL WITH OUTER CAN|unknown info root_cause
ZF|100048038|09/10/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|NOCO NOPT NOTE ATCO|assembly test|cleanliness|scm|scm|vendor|test error|Cleanliness  General|Failure to clean inside of the outer can
ZF|100052701|03/04/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|test omitted|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|No communication w. MPFM|Not able to upload correct SW
ZB|7101401|23/05/2003|priority 3 |Q1|PETROBRAS|unknown info region|NOTE NOCO NOPT|service maintenance|unknown info damage_desc|scm electrical|other scm electrical|assembly test|assembly test error|SCM 2 Marlim El-can A malfunction|unknown info root_cause
ZF|3812476|08/04/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|documentation|missing certificates records|scm|scm|projects|documentation error|Missing documentation from receiving|unknown info root_cause
Q3|100001156|29/03/2001|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTI|scm rcm|scm|defect locations onshore|goods receipt inspection|root cause other|logisticspacking shipping damage|TRANSPORTSKADE PÅ SCM OG SKID|Uforsvarlig truckkjøring
ZB|P6000043122|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM SSS 01|Software improvement/correction
ZF|P6000107991|22/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|electronic boards|dhi|vendor|clarification|Gauge Timeouts|Follow-up in QN 200376395
ZE|P6000076121|24/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|component error|test and transportation|sensor simulator (sesi)|projects|documentation error|CITV  no connection with module/ST|Documentation error
ZF|P6000069056|22/06/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|design|specification error|scm|scm|engineering|continuous improvement|El schematic wrong description for TCSA|Comments in El Schematic now corrected
ZF|100017278|28/05/2004|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|vendor|unknown info damage_desc|scm mech w mb|other scm mechanical|vendor|material error|SILICON OIL IN THE BLADDER COMPENSATOR|Hydrogen embrittlement. (Broken bolts.)
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Bytting transusere.|unknown info root_cause
ZF|P6000119335|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|machining|thread error|scm hyd mech components|outer can|engineering|engineering error|To short threads in outercan|Interface with EC adapter not verified
ZD|P6000084242|08/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PARTNUMBER|INCORRECT PARTNUMBER
ZF|P6000126219|28/09/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|leak|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Silicone contamination after hyperbaric|Test connection not according to SPC
ZE|P6000088751|06/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|scmmb|other mechanical components|qa qs qi|documentation error|Update FAT GWF-2 scm|TST60081959 rev.H updated and released
ZF|P7000020444|12/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|component error|test and transportation|test & flushing plate|vendor|tooling|Hyperbaric chamber test failed|unknown info root_cause
ZE|P6000105708|06/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Forbedringer på Julia SRM|Drawing  BOM and procedure update
ZF|100020562|26/05/2004|priority 3 |Q3|BP|GOM|NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Sand Detector Simulator is not working|unknown info root_cause
ZF|7104033|07/05/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|ss intervention running tool|scm running tool|vendor audit|unknown info cause_desc|Possible leak on return compensator|Operator misunderstood function.
ZF|P7000016420|02/06/2011|priority 1 |Q3|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|Falha no flowmeter de retorno LP.|Flow Meter Inoperante
ZF|P6000105708|11/10/2015|priority 2 |Q3|EXXONMOBIL|unknown info region|NOCO NOTE|documentation|procedure process error|scm|scm|service :|damaged during installation|SRM bladder Ruptured|SRM stored outside topped up
ZF|7103233|04/01/2012|priority 2 |Q3|SUNCOR CPI|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Material not delivered to plant|unknown info root_cause
ZE|100031223|19/04/2005|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO|damage|damage during assembly|scm|scm|variance|unknown info cause_desc|Damaged tronic el-connector.|Assembly / handling error.
ZF|P6000055605|20/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|other defect|functional|scm hyd mech components|other hydraulic components|other causes damage|cause not found|Child QN Valves not stroking On XT #8 .|Valves not stroking
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|NOPT ATCO NOTE NOCO|test|test omitted|scm|scm|qa qs qi|documentation error|Missing sign offs|missed sign off
ZF|P7000000897|11/06/2012|priority 1 |Q3|SHELL|unknown info region|NOCO NOTE ATCO NOPT|damage|damage from corrosion|scm hyd mech components|outer can|other external causes|customer error responsibility|Difficulty to remove screws.|SCM MMR
Q3|100006360|04/04/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTI|mechanical|hydraulic manifold block|defect locations onshore|workshop other|initial direct product problem|dimension|SCM 03  wrong type of flow restrictor|unknown info root_cause
ZF|100035013|23/01/2006|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO NOPT ATCO|assembly test|assembled incorrectly|scm|scm|assy|operator error|Problem operating MDV on XT|"Incorrect ""blind plate"" assembled"
ZD|P6000039844|16/02/2009|priority 1 |Q2|SHELL|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|assy|unknown info cause_desc|(SS) DEFECT IN SEM B DURING TESTING|Damaged electrical component   op.ampl
ZF|100049392|02/07/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of test equipment
ZB|100031223|19/04/2005|priority 2 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO|damage|damage during assembly|scm|scm|assy|missing operation|Damaged tronic el-connector.|Assembly / handling error.
ZF|P6000068912|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100058509|03/08/2011|priority 2 |Q3|LLOG|GOM|ATCO NOTE NOCO|design|specification error|computer system software|etu sw|engineering|engineering error|Error in ETU Trending|unknown info root_cause
ZE|P6000091085|13/05/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|documentation|OWIRS Deadman sequence|QN Cancelled
ZF|P7000039672|03/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|assembled incorrectly|scm hyd mech components|hydraulic manifold adapter plate|assy|operator error|ERRO NA APLICAÇÃO DE TORQUE|unknown info root_cause
Q1|7102643|05/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|damages|SCM 03 ÅsgA G-3H HP ret. valve Blocked|unknown info root_cause
ZB|100038200|11/09/2006|priority 1 |Q1|SHELL|unknown info region|NOPT NOCO NOTE|documentation|incorrect user documentation (customer)|scm mech w mb|locking mechanisms|manufacturing|tooling error|Unable to lock SCM to tree.|wrong documentation
ZF|7103233|19/05/2007|priority 3 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|NOTE NOPT NOCO|other defect|unknown info damage_desc|scm|scm|other causes damage|qn cancelled|Poor sound in SCM|see SN 300162766
ZB|100035118|08/01/2016|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|intercompany|kongsberg|WEL  Test Failure  L1 Escape|unknown info root_cause
ZF|P6000068902|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|21/12/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|SEM COMUNICAÇÃO DHI A|unknown info root_cause
ZF|7101401|31/03/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOCO NOTE|machining|position error|scm hyd mech components|outer can|machine shop personnel|operator error|MMR - Outer Can Base Screw Holes|unknown info root_cause
ZF|P7000000897|31/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly|assembled incorrectly|scm|scm|assy|damaged during assembly|lock mechanism blocked|unknown info root_cause
ZF|100025661|29/03/2006|priority unknown info priority|Q3|PETROBRAS|GOM|NOCO NOPT NOTE ATCO|change deviation request|part substitution request|scm|scm|assy|missing operation|Deviation from BOM  Cottonwood - SCM 1|SCM deviation of LP and HP valves
ZF|P6000028371|26/05/2008|priority 3 |Q3|SHELL|GOM|NOPT NOTE NOCO|documentation|missing certificates records|scm|scm|engineering|unknown info cause_desc|Batch numbers missing in iBASE list|Change: batch cert. to batch management
ZF|100055600|01/06/2010|priority 2 |Q3|REMINGTON OIL AND GASHOUSTON STOCKING SCM MK II (15K)|unknown info region|NOTE NOCO NOPT|test|missed operation|scm|sem|qa qs qi|final inspection error|SCM ASSY|lack of process understanding.
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE|other defect|unknown info damage_desc|fks quality system issues|quality management system|other causes damage|unknown info cause_desc|Rosa 401 invalid pressure sensor reading|unknown info root_cause
ZF|P7000001843|16/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|damage|damage during testing|scm hyd mech components|outer can|test|damaged during testing|Mexilhão #08 - Avaria após Hiperbárico|MMR SCM
ZF|P6000102554|18/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|drawing error|scm sem el opt component|sem cable & wiring|engineering|engineering error|EC7 pin 11 and 12 wired wrong|Eng. error in wiring list LST60095676
ZF|100037966|23/01/2008|priority 2 |Q3|BP|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|scm|scm|assy|unknown info cause_desc|Incorrect results on SEM B card|unknown info root_cause
Q3|100006609|12/03/2001|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTI NOCO NOPT|hydraulic|accumulators|defect locations offshore field|campos basin|initial direct product problem|leakage|Leak of silicone oil from comp. bladder|Too much silicone - filling PRD changed
ZF|P7000024900|28/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|coating plating|coating defect|scm hyd mech components|outer can|other causes damage|damage during transport|Scratch inside of the Outer Can|101545 - KRISTIANSANDS SKRUEFABRIKK
ZF|P6000093501|31/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|machining|thread error|scm hyd mech components|outer can|vendor|specification not followed|outcan is not coret thread|Bad threads for EC slot on outercan
ZF|P6000125394|25/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|drawing error|scm|scm|engineering|dbi error|Check valve not in drawing.|Check valve missing in part BOM
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|unknown info root_cause
ZB|P6000063531|03/05/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|electrical|component failure|object types to eng matl class|scm|test|damaged during testing|Vigdis OH19 Power supply error|High Voltage during testing
ZF|P7000039672|03/11/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|marking|no marking|scm hyd mech components|other hydraulic components|materials stores|improper packaging & storage|Relief valve sem marcação|134871 - Pall do Brasil Ltda
ZF|P7000000897|09/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|component error|scm|scm|purchasing|purchasing error|SEM Review|delay in delivering for workshop test
ZF|P6000104111|10/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|design|specification error|computer system software|sem tpu config|engineering|engineering error|Smarttool config|unknown info root_cause
ZF|P7000008275|11/06/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|other defect|physical|scm|scm|other causes damage|cause not found|Falha na leitura do PDG da SEM A|Falha de comunicação
ZF|7101463|08/09/2010|priority 3 |Q3|EXXONMOBIL|unknown info region|ATCO NOTE NOCO NOPT|documentation|incorrect certificates records|scm|scm|assy|operator error|Missing Sign-offs|unknown info root_cause
ZF|P6000055605|25/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SEM failure detected in extend. test
Q3|7104670|06/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|product defects for dept.|test equipment|defect locations onshore|fat|initial direct product problem|function|HNF SCM 05|unknown info root_cause
ZF|P7000016420|19/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|damage|damage during assembly|scm hyd mech components|hydraulic tubing|other causes damage|damage from wear and tear|Tubo de Vácuo|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZE|P6000084242|10/10/2013|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|SEM A failure to communicate with SPCTU|Communication failed
ZF|P6000058949|02/09/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|electronic boards|comm.link (power line)|vendor|clarification|Communication Problem SEM A|Follow-up covered by QN200182969
ZF|P6000042968|03/04/2010|priority 1 |Q3|TOTAL|WEST AFRICA|NOTE NOPT ATCO NOCO|test|component error|scm|scm|vendor|equipment malfunction|Flow meter not responding during HFT|Flowmeter returned to vendor
ZE|P6000088604|11/08/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|other defect|part lost|scm|scm|assy|missing parts|(CDM) Missing API bucket for SCM|Missing API bucket for SCM
ZF|P6000029772|10/09/2009|priority 1 |Q3|ENGIE|NORTH SEA|NOPT NOCO NOTE ATCO|damage|damage during assembly|scm|scm|other causes damage|unknown info cause_desc|OC2 and OC3 fiber dirty|Damaged connector
ZF|100026567|08/01/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly test|assembled incorrectly|scm|sem|assy|operator error|CITV not working properly|Human error when modifying wiring
Q3|7100320|02/12/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|material|Upgrade Hercules SCM 12-GAMA to 12-OMEGA|Wrong materials
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
ZF|100048038|12/09/2007|priority 2 |Q3|AGBAMI|unknown info region|NOTE NOPT NOCO ATCO|design|dbi error|scm|scm|other causes|no noncompliance|Exposed Electrical Connector|NO NON-COMPLIANCE
ZF|P7000001843|14/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|damage|damage during testing|scm|scm|other external causes|customer error responsibility|Outer Can|Amasso na Outer
ZF|P6000104111|28/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|No power to DIU from SEM B|Wire not connected to earth bar
Q3|7104670|20/03/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|workshop|initial direct product problem|function|SCM  flowmeters HP+LP read too high|unknown info root_cause
ZB|7104075|25/10/2006|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|assembly test|interface of components issue|xmas tree|production master valve (pmv)|vendor|component error|PMV malfunction.|Pressure sensor malfunction.
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|scm rcm|scm|defect locations offshore field|shell alliance gom|root cause vendor|assembly fabrication test error|Shell SCM Communication problem|Vendor changed colors on wires
Q3|7102643|09/10/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|electrical|pressure transducer|defect locations offshore field|åsgard a|initial direct product problem|function|LP supply PT stuck at 316 bar  well N-4H|unknown info root_cause
ZF|7102969|21/10/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|design|user documentation procedures|scm|scm|vendor|vendor design error|Procedure incorrect for RIT of Megi SCM|TST DOCUMENT DISCREPANCY
ZF|100025661|01/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|design|dbi error|scm|scm|engineering|dbi error|Docs/Shell/SCM/PN and Docs Don't Match|unknown info root_cause
Q1|7104422|unknown info defect_date|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|product defects for dept.|scm|defect locations onshore|workshop|problem causes defect causes|maintenance|SCM HFT test procedures are missing|KOSKBG have not sent procedures
Q1|7103234|22/05/2002|priority 3 |Q1|SUNCOR CPI|unknown info region|NOPT NOCO NOTI|electrical|pressure transducer|defect locations offshore field|fpso terra nova|initial direct product problem|function|SCM PT DHSL function has +25bar offset|PT malfunction/cause not yet known
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|hydraulic|hydraulic control valves|defect locations onshore|montasje|initial direct product problem|material|Replacement of solenoids (upgrade)|Internal aluminium washers were fitted
ZF|100058509|03/08/2011|priority 2 |Q3|LLOG|GOM|NOTE NOCO|test|function|topside products|other topside products|other causes damage|qn cancelled|Trending errors in LLOG ETU|Cancelled duplicate as SN 300280430
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000024191|02/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|physical damage|scm hyd mech components|other mechanical components|vendor|specification not followed|Spacer não monta / Spacer does not fit|104327 - FAITH MFG. CO. INC.
ZF|100037965|12/04/2010|priority 3 |Q3|BP|unknown info region|NOPT NOCO NOTE|other defect|functional|scm|sem|engineering|engineering error|Software error.|DH card  configuration update
ZF|P7000039672|25/10/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOPT NOCO NOTE ATCO|damage|damage due to handling|scm hyd mech components|other mechanical components|assy|improper handling|MMR - Screw/Securing Plate from El. Can|Improper handling of tool
ZE|7104670|24/05/2016|priority 2 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|computer system software|etu sw|causes for improvement|process procedure ineffective|Lack of config file during maintenance|unknown info root_cause
ZF|P6000068912|29/06/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|design|drawing error|scm hyd mech components|outer can|assy|operator error|GAS PRECHARGE PORT REMOVE FROM DRAWING|ECN change  during assembly
Q3|7101172|02/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|gullfaks a|initial direct product problem|function|PT/TT upstream choke. H-1H|unknown info root_cause
Q3|7101172|02/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|hydraulic|hydraulic control valves|defect locations offshore field|gullfaks a|root cause other|customercustomer error|GFS SCM 14  LP supply leak on Well H-1H|Wrong fluid (Castrol GF30) used
ZF|100017997|18/08/2006|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly test|do not use|scm|scm|assy|missing operation|SCM In-House FAT  wrong fluid used|failure to follow project procedure
ZF|P6000074156|08/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|vendor|specification not followed|PT 18 show no value when using SEM B|Label on wires incorrect from supplier.
ZF|100030542|30/03/2006|priority 2 |Q3|BAOBAB|unknown info region|NOCO NOPT ATCO NOTE|damage|unknown info damage_desc|scm|scm|unknown info cause_group_desc|unknown info cause_desc|FNCR RAISED FOR CNR Baobab SCM|Cause not yet known  see SN300088479
ZD|100020562|12/08/2010|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|marking|marking content error|scm|scm|vendor|material error|Tool Mark|Tool Mark
ZE|P6000068902|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update SCM PSM - Luanda Workshop|Update is followed up in QN 200439169
ZF|100067526|01/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|engineering error|Gullfaks 7 DBA Drwaing|Bom and drawing error.
ZF|7104670|27/02/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|damage|damage during testing|scm electrical|i o pcbs|other causes|do not use|SCM 10 Heidrun SIO SEM A malfunction|expected unauthorized voltage at input
ZF|7101401|05/11/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|welding|miscellaneous|scm dummy scmmb test & fl|outercan|fabrication shop personnel|operator error|Ângulo do Bisel|angulo do bisel
ZF|P6000079032|29/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|instrumentation|other scm instruments|other causes damage|cause not found|CR Unable to perform test accord to HFT|CR issued to customer  lack of test eq.
ZB|P6000042968|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 15|Software improvement/correction
ZE|P6000105542|07/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Error on drawing|Dwg is correct  QN cancelled
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|100037966|20/10/2006|priority 1 |Q3|BP|unknown info region|NOTE ATCO NOPT NOCO|assembly test|function|scm|sem|engineering|engineering error|Malfunctioning  receiving test.|Test procedure correction
ZF|100037966|06/04/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|marking|marking content error|scm|scm|engineering|dwg error|Top of SCM  marking is too big|Drawing error
Q1|7102969|03/03/2003|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE NOPT|scm rcm|scm|ext. loc. kos houston|work shop|initial direct product problem|function|Failure on SEM A|unknown info root_cause
Q3|7100320|unknown info defect_date|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 05-BETA til 05-OMEGA|unknown info root_cause
ZF|P7000039672|22/12/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|assembled incorrectly|scm el opt components|el. connector|vendor|final inspection error|Tygn Hose com diametro maior|unknown info root_cause
ZB|P6000039844|13/08/2009|priority 1 |Q1|SHELL|unknown info region|NOPT NOCO NOTE|coating plating|coating defect|scm|scm|assy|operator error|Rust appeared at SCM top plate area|Follow up in QN 200136409
ZF|100037427|15/03/2005|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|design|drawing error|scm|scm|engineering|engineering error|Wrong readings detected during EFAT|unknown info root_cause
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL ATCO NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000024191|10/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
ZF|P7000001621|13/08/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|ss compl. & w.over xt general|horizontal penetrators|engineering|engineering error|Fechamento da outer can Hercules 03|Interferencia mecanica nos filtro
ZB|P7000000897|08/05/2015|priority 4 |Q1|SHELL|unknown info region|NOTE ATCO NOCO|damage|damage from corrosion|scm hyd mech components|locking mechanism|other external causes|customer error responsibility|BC-10 - Fail to Unlock SCM #12|Lack of preservation procedures
ZB|100033987|15/11/2004|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|procedure error|scm|scm|engineering|engineering error|ÅsgBB84 VO-01 Prep SCM assy|unknown info root_cause
ZF|P6000042969|25/11/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|other defect|part lost|scmmb|other hydraulic components|intercompany|kongsberg|Feil plukk av hydralic  plug hex hea|Picking fault in warehouse
ZF|P7000024191|04/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|Protection ring Ovalizada|Peça ovalizada
ZF|P6000063531|10/01/2019|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM  SEM's damaged by P6000067816 at EC4|unknown info root_cause
Q1|7102643|16/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTI ATCO NOPT|electrical sensor equipment|pressure temperature transmitters|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 13 ÅsgA L-1H PT Func. line 11 malfun|unknown info root_cause
ZF|P7000016420|14/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|electric products|electrical connector|materials stores|improper packaging & storage|fio do conector está mordido|unknown info root_cause
ZF|P6000064911|31/05/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|object types to eng matl class|scm_running_tool|other causes damage|planning error|Cust. Dev. - S3 Work Omitted|unknown info root_cause
Q3|7103234|19/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|hydraulic|hydraulic coupler|defect locations onshore|montasje|initial direct product problem|function|Install hydaulic flow restrictors|unknown info root_cause
ZF|100038200|24/07/2006|priority 3 |Q3|LLOG|GOM|NOCO ATCO NOTE NOPT|design|procedure error|scm|scm|vendor|test error|CANNOT PERFORM HFT SECTION|no  CITV Simulator identified
Q3|7104075|10/10/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|electrical|dhi interface|defect locations onshore|workshop other|initial direct product problem|function|SCM requires DHI-108 card modification|unknown info root_cause
Q1|100017278|21/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTI|hydraulic|accumulators|defect locations onshore|workshop|root cause vendor|design error|SCM 56 ÅSG LP Acc. leak. in top|unknown info root_cause
ZF|P6000042969|27/04/2011|priority 2 |Q3|TOTAL|WEST AFRICA|NOTE NOPT NOCO|coating plating|incorrect colour coating|scm hyd mech components|outer can|other causes damage|qn cancelled|Wrong coulor on the outer can|Qn cancelled.Use as is
Q3|100018600|18/03/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTI NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|B electronic seems to fail|unknown info root_cause
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|unknown info root_cause
Q2|7101172|05/03/2001|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM DHPT  data transmission stopped|Down Hole gauge - Roxar's problem
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZD|100020278|28/09/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|coating plating|incorrect colour coating|scm hyd mech components|outer can|vendor|coating defect|Outer Can Coating|unknown info root_cause
ZF|100049000|18/07/2011|priority 2 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|machining|position error|scm|scm|other causes damage|no noncompliance|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100017305|08/04/2003|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Olje går ikke mellom filter|unknown info root_cause
ZF|100030542|14/02/2006|priority 3 |Q3|CNR|unknown info region|NOTE ATCO NOPT NOCO|damage|damage during transport|scm|scm|other external causes|customer error responsibility|FNCR D01083 Raised on Baobab|Handling at airport
ZF|100056176|11/06/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE|documentation|missing certificates records|scm|scm|other causes damage|no noncompliance|Batch numbers missing|QC change to batch management
ZF|100034629|21/10/2005|priority 3 |Q3|STATOIL|unknown info region|NOPT NOCO NOTE ATCO|marking|marking content error|scm|scm|vendor|component error|CHANNEL 1 AND 5 IS WRONG MARKED|Incorrect marking of connector.
ZF|100030711|01/04/2004|priority 2 |Q3|STATOIL|unknown info region|NOTE ATCO NOCO NOPT|assembly test|workmanship general|scm mech w mb|outer can|assembly test|operator error|Switched outercan between SCM13 & SCM14|unknown info root_cause
ZF|P7000020444|18/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm el opt components|opt. connector|other causes damage|cause not found|Penetrador näo monta.|impossibilidade de realizar dimensional
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|NOCO NOPT NOTE ATCO|assembly test|do not use|scm|sem|vendor|component error|SO due to DC/DC Issue on AI150 card|Component Failure/Poor Workmanship
Q1|7105129|28/02/2003|priority 3 |Q1|TOTAL|unknown info region|NOPT ATCO NOTI NOCO|electrical|sem el.rack|ext. loc. luanda (angola)|work shop|initial direct product problem|function|SCM 2I GIR communication problems SEM B|unknown info root_cause
ZF|P7000039672|25/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Vazamento na adapter plate de LP PS#17|123643 - BOSCH REXROTH  LTDA
ZF|P6000068924|16/11/2011|priority 1 |Q3|TOTAL|unknown info region|NOCO NOTE NOPT|design|procedure error|scm el opt components|scm wiring|engineering|procedure error|Wrong use of miniseal|Error in PRD. follow up in QN200232669
ZB|100048038|03/12/2008|priority 2 |Q1|CHEVRON|WEST AFRICA|NOCO NOTE|test|function|scm electrical|processor pcbs|other causes damage|cause not found|SCM #20 SEM A FAILURE (No Comms)|SCM #20 SEM A FAILURE (No Comms)
ZF|P6000079032|27/04/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|test|function|electronic boards|main boards cpu & i o|vendor|clarification|Communication error PSD|Investigation & Follow-up in QN200265826
Q3|3812476|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTI NOPT ATCO|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|function|SCM to be repaired|unknown info root_cause
Q3|7102643|24/08/2001|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI ATCO|mechanical|locking mechanism|defect locations onshore (hes)|kongsberg a b|initial direct product problem|coating|Locking mechanism lacks xylan|unknown info root_cause
ZF|100048038|12/04/2007|priority 2 |Q3|AGBAMI|unknown info region|NOCO NOTE NOPT ATCO|assembly test|function|scm|scm|other external causes|customer error responsibility|LP pressure changes AGB SN 25|New requirements from customer
ZF|7103233|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|other defect|functional|scm|scm|other external causes|unknown info cause_desc|Low flow|unknown info root_cause
ZB|P6000098616|17/10/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|scm sem el opt component|other scm sem el opt components|engineering|engineering error|Stones Claim  SCM #421|Earthing of CPU card missing
ZF|7102643|06/07/2011|priority 1 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|test|function|scm|scm|engineering|engineering error|Fluenta sanddetector not working|unknown info root_cause
ZB|100052701|11/11/2010|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT|damage|damage due to handling|customer compliant|noncompliance to customer requirement|other causes damage|planning error|B&B Damaged SCM receptacle|Incorrect jumper installed.
ZF|3812476|04/07/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly test|interface of components issue|scm|scm|other causes damage|planning error|Had to modify SCM to secure it in skid|Bad planning during mob
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000105708|19/02/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|OC wiring fault|Wiring error during outercan closing
ZF|P6000039844|22/08/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|electrical|other specify in comments|object types to eng matl class|scm|test|incorrect set up testing|Missing test equipment / CR request|unknown info root_cause
ZF|P6000104116|21/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|machining|surface finish error|scm hyd mech components|other mechanical components|vendor|specification not followed|Sealing surface not within accept crit|Seling surface outside of accep. crit.
ZE|100018531|16/01/2017|priority 3 |Q3|SHELL|unknown info region|NOTE ATCO NOCO|assembly|missing components|scm el opt components|el. connector|causes for improvement|process procedure not being followed|MMR - EC4 Assembly without O-ring|unknown info root_cause
ZD|7101463|29/01/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage due to handling|scm hyd mech components|outer can|vendor|operator error|Damage to the ROV bucket bore area|unknown info root_cause
ZF|P6000093498|04/03/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|imension (tolerance)|instrumentation|scm flowmeter|engineering|engineering error|FM  verification of assembly|FM  verification of assembly
ZF|100054943|12/03/2008|priority 2 |Q3|WOODSIDE|unknown info region|NOPT NOTE NOCO|assembly test|missed operationassy test|scm|scm|other causes damage|unknown info cause_desc|(SS) SCM NOT FULLY UNLOCKED|CONTROLS TECHNICIAN ERROR
Q3|7104670|03/02/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|product defects for dept.|scm|defect locations onshore|workshop|initial direct product problem|marking|Fargemerkning av topp og side på S/N 04|unknown info root_cause
Q1|7104075|27/12/2000|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|hydraulic|hydraulic control valves|defect locations offshore field|shell alliance gom|root cause engineering|other product design error|COntrol Valve failure|See FNCR
ZF|100038200|20/02/2006|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|scm|scm|vendor|component error|SCM POWER INSUFFICIENT TO POWER SKOFLO|High inrush current need in SKOFLOsensor
ZF|3794920|29/01/2004|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Mob SCM SSP 37 Statfj F&D 18           *|unknown info root_cause
ZF|P6000042968|13/05/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|function|electronic boards|dhi|vendor|unknown info cause_desc|Cards fails to read gauges|Error to be confirmed in QN200128479
ZF|P6000090632|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SEM failure detected in extend. test
Q1|7104075|05/11/2001|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|customer goods receipt|initial direct product problem|damages|Silicone oil leaking from SCM  offshore|SCM compensator bladder damaged
ZF|P7000008275|28/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm hyd mech components|outer can|other causes damage|damage from wear and tear|Revestimento / Roscas danificadas|Peça no estoque por muito tempoFalta de revestimento
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOTE NOPT NOCO ATCO|machining|angle error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZB|100031223|16/06/2004|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM adress on SCM not identified|unknown info root_cause
ZF|100049000|22/03/2006|priority 2 |Q3|BP|GOM|NOTE NOPT NOCO ATCO|change deviation request|part substitution request|scm|scm|other causes|qa qs qi error|Incorrect part number|Receiving Insp. Error
Q3|7106268|25/10/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations onshore|fks xmas tree fcm workshop|initial direct product problem|function|SCM I/DHI 04|unknown info root_cause
ZF|100050383|30/03/2007|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|assembly test|interface of components issue|scm|sem|other causes|no noncompliance|Problems with SEM outercan assembly|Marginal design
ZF|P6000042968|13/05/2009|priority 1 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT|test|function|electronic boards|dhi|vendor|unknown info cause_desc|Cards fails to read gauges|Error to be confirmed in QN200128479
ZF|100049000|19/07/2011|priority 3 |Q3|BP|unknown info region|NOTE NOPT ATCO NOCO|machining|position error|scm|scm|other causes damage|no noncompliance|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100046112|21/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|electronic boards|main boards cpu & i o|vendor|clarification|Possible CPU and AI failure|Cause not yet found  cards to be invest.
ZF|100036936|22/11/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTE NOCO|assembly test|missed operationassy test|scm|scm|other external causes|customer error responsibility|HFT not performed|Due to lack of time
ZF|7104670|26/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Misguiding information in TPR-0011175|Misguiding information in TPR-0011175
ZE|P6000069820|28/08/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|(CDM)SCM has lost its redundancy|Bad Sensor Values
ZF|7102969|26/05/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|damage|damage during testing|scm|scm|other causes|do not use|SCM UNFIT FOR USE AS SPARE/REPLACEMENT|LP hyd. over pressured during testing
ZF|100037966|16/12/2005|priority 3 |Q3|BP|unknown info region|ATCO NOTE NOPT NOCO|assembly test|cleanliness|scm|scm|assy|missing operation|SCM hydaulic cleanliness out of spec.|SCM contaminated by external equipment
ZF|100016901|05/01/2004|priority 3 |Q3|BP|GOM|NOPT NOTE NOCO|service maintenance|unknown info damage_desc|scm electrical|pressure transducers|operation maintenance|expected wear and tear|PT failure|Unknown error. It may be a PT error.
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO DLFL|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZB|P6000043122|03/08/2013|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOCO ATCO NOTE|other defect|functional|scm|scm|vendor|equipment malfunction|SCM Fault on Pazflor!|Optical penetrator leak to be confirmed
ZF|P6000055213|21/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm|scm|other causes damage|cause not found|Oil in silicon.|Oil found is from outercan installation
ZB|100001156|06/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOTE NOPT NOCO|test|function|scm|scm|other external causes|customer error responsibility|Guarantee claim 130 - SCSSV fu. transmit|Unknown reason for failure
ZF|P7000024191|01/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|interface issue|scm|scm|assy|operator error|Interferência do trafo na calha|unknown info root_cause
ZF|P6000068924|21/08/2011|priority 3 |Q3|TOTAL|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|block not attached to baseplate|Bolts not installed in SRM baseplate.
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|electrical|pressure transducer|defect locations onshore|workshop other|initial direct product problem|material|Change out of poor quality PTs|unknown info root_cause
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCVs and strainer|DCV/COV with Cobalt pilot ball
ZF|100035400|20/01/2006|priority 3 |Q3|HESS|GOM|ATCO NOTE NOPT NOCO|design|user documentation procedures|scm|scm|vendor|assembly error|SIO CHANEL 5 IS DISPLAYING TIME OUT|SIO CHANEL 5 IS DISPLAYING TIME OUT
ZF|7103233|28/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|design|drawing error|scm|scm|engineering|dwg error|DWG-0208689-001 needs update|Drawing incorrect  see QN200166338
ZF|P6000042968|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|19/01/2018|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|function|object types to eng matl class|scm|assy|operator error|Ausência de leitura no sensor externo|unknown info root_cause
ZF|P7000001621|02/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|interface issue|scm|scm|other causes damage|cause not found|Furação fora de centro na Outer Can|decorrente do processo de reparo
ZF|P6000088626|12/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|change deviation request|raw material substitution request|scm hyd mech components|other mechanical components|assy|missing parts|missing inconel screws|Inconel 718 screws missing in stock
ZF|100025661|08/08/2005|priority 2 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|assembly test|function|scm|scm|vendor|component error|INTERNAL PT OUT OF RANGE|INTERNAL PT OUT OF RANGE
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|assembly test|cleanliness|scm|scm|materials stores|improper packaging & storage|SCM was full of calcium and rust|Not sufficient cleaned and preserved
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
Q2|7102969|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|hydraulic|hydraulic control valves|defect locations onshore|workshop other|initial direct product problem|material|Bytting solenoider på ventiler.|unknown info root_cause
ZF|P6000064911|02/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|design|specification error|computer system software|sem tpu config|engineering|engineering error|Config|unknown info root_cause
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000024191|28/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|leakage (fluid)|scm|scm|other causes damage|cause not found|PORCENTUAL DE ACEITAÇÃO FORA DO DESEJADO|PROBLEMA NO EQUIPAMENTO DE TESTE
ZF|P7000008275|20/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|outer can|assy|damaged during assembly|Arranhão na outercan|unknown info root_cause
ZF|P6000068902|09/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|PT/TT wiring error|PT\TT wiring error. Operator error.
ZF|P7000002082|19/02/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|damage|damage during assembly|scm|scm|assy|damaged during assembly|Vazamento de Silicone|Silicon Leakage
ZF|100049000|10/12/2009|priority 3 |Q3|BP|unknown info region|NOCO NOTE NOPT ATCO|damage|damage due to handling|scm|scm|test|incorrect set up testing|Damaged shear pin|SCM installed on incorrect SCMMB bush
ZF|P7000001843|25/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|coating plating|coating defect|scm|scm|other causes damage|damage from wear and tear|Oxidação Extension Rod Mexilhão RRP 05|unknown info root_cause
ZB|100031223|22/04/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|other external causes|customer error responsibility|Warranty claim 261-GullfaksC-Com.probSCM|unknown info root_cause
ZF|P6000042968|26/02/2010|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|design|specification error|topside products|n a sw|engineering|engineering error|DHI error message received in ST report|unknown info root_cause
ZF|100034440|04/11/2005|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|do not use|scm|scm|assy|operator error|LOOSE SCREWS|paint prevent sufficient holding tension
ZB|100020562|11/05/2010|priority 3 |Q1|BP|GOM|ATCO NOCO NOTE|damage|damage during assembly|scm mech w mb|locking mechanisms|assy|operator error|Over torqued to the skid|Over torqued to the skid
ZF|100046387|25/07/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|missed operation|scm|scm|test|missing parts|CITV test during DEMOB|Lack of available CPI test equipment
ZF|P7000039672|07/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|damage due to handling|scm sem el opt component|other scm sem el opt components|test|improper handling|Revestimento danificado|unknown info root_cause
ZE|P6000074156|03/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|change seq. of procedure|(CDM)SCM #410 Hydroulic PT sensor failed|Hydroulic PT sensor failed
ZE|100056918|02/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|SCM Leak Test Fail|Cannot Hold Pressure
ZF|7105128|18/02/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly test|miscellaneous|scm hydraulic|hydraulic control valves|other causes|miscellaneous|CV PMV leaked on 1st operation from LPA|Unrepeatable leak in LP control valve.
Q3|100006609|12/02/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|No communication with SEM A|unknown info root_cause
Q3|7101172|17/10/2001|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM Leak from SCSSV-solenoid to return|SCSSV HPCV leaking
ZB|7102969|03/01/2007|priority 2 |Q1|MOBIL EG|unknown info region|NOCO NOTE ATCO|assembly test|function|scm el. act.syst|control electronics|other causes|do not use|Unable to establish communications|To be inspected upon retrieval.
ZF|P6000083428|24/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|missed operation|scm hyd mech components|control valve|test|operator error|Change over valve failues to function|operator error during test set-up
ZE|P6000123495|06/04/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|causes for improvement|process procedure not being followed|High internal leakage - control valves|High internal leakage - control valves
ZB|P6000042969|23/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT ATCO NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 03|Software improvement/correction
ZF|100025735|21/02/2014|priority 3 |Q3|OVERALL PROJECT ROLL-UP SKIRNE / BYGGVEWELL NO E-1H - BLOCK 25/5-3|unknown info region|NOTE ATCO NOCO|test|cleanliness|scm|scm|test|operator error|Brayco SCM flushed with Transaqua HT2|Flushed Brayco SCM with waterbased fluid
ZB|P6000101955|04/07/2014|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|other defect|physical|scm|scm|test|missed operation|SCM 2&3 TYR Silicon filling / mob issues|unknown info root_cause
ZF|100037965|16/05/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|damage|wear & tear|scm|scm|engineering|procedure error|SCM locking mechanism damage during ops|torque in procedure potentially too high
ZF|P6000079433|13/02/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|function|scm|scm|assy|operator error|CVLP4 and CVHP24 Not working as expected|Opr.error when wiring SCM  Spec OK
ZF|7101401|24/10/2014|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|engineering|continuous improvement|MMR - CVLP19 External Leakage|unknown info root_cause
ZF|P6000050867|26/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|computer system software|electrical solution sw|engineering|engineering error|FAT stopped due to software problems|FMC Engineering : Engineering Err
Q3|7105128|05/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|mechanical|outer can|def. loc. testing (not int. scm)|swt (shallow water test)|initial direct product problem|marking|SCM P 01|unknown info root_cause
Q3|100017997|12/06/2002|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|product not qualified|SCM  various punches at final inspection|New hydraulic couplers not yet qualified
Q1|7102643|16/07/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 24 ÅsgA I2-H PT XOV malfunction|unknown info root_cause
ZE|100048038|03/04/2017|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|causes for improvement|documentation|(Alert) - #138 TQ -O- SCM|unknown info root_cause
ZB|P6000063531|25/07/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|object types to eng matl class|scm|other external causes|customer error responsibility|Vigdis ALD function failed mobilisation|TFMC does not accept liability
ZF|P7000039672|30/03/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|Vazamento no Manifold Block|unknown info root_cause
ZB|100067526|28/10/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm|scm|other causes damage|no noncompliance|GC 266 SCM Comm. probl.|component failure inside/external errors
ZF|P7000016420|13/12/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|scm|scm|other causes damage|cause not found|Filtro do compensador|unknown info root_cause
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|other defect|functional|fks quality system issues|resource management|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
Q1|7105129|31/01/2003|priority 3 |Q1|TOTAL|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|ext. loc. luanda (angola)|work shop|initial direct product problem|function|SCM 07I GIR communication problems SEM A|unknown info root_cause
Q1|7102643|unknown info defect_date|priority 1 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|product defects for dept.|scm|defect locations onshore|workshop|root cause qa qs|qa qs inspection error|SCM 14  el. conn. lock ring missing|Missed on final inspection
ZF|100020562|03/08/2009|priority 2 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|other defect|functional|scm|scm|vendor|material error|Voltage reference error|Defective DC/DC converter (Datel)
ZF|P6000042968|03/03/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|other defect|functional|topside products|n a sw|engineering|engineering error|New config due to software upgrade.|unknown info root_cause
ZF|100066325|11/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|ss compl. & w.over xt general|electrical connectors|engineering|specification error|El connector fault SSP OH003 (Statfjord)|unknown info root_cause
ZF|P7000000897|17/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|marking|marking content error|scm hyd mech components|outer can|vendor|specification not followed|Lock/UnLock out of the specification|101545 - KRISTIANSANDS SKRUEFABRIKK &
ZF|P6000064909|05/10/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring fault on EC5|Human failure  wrong wiring (spec is OK)
ZF|P6000029772|25/03/2009|priority 1 |Q3|ENGIE|NORTH SEA|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|other causes damage|no noncompliance|Batch missing on outercan bolts|change to batch management
ZF|P6000101955|12/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|drawing error|scm|scm|engineering|dbi error|Wrong nameplates used on SCM`s|Wrong nameplates in dwg
ZD|P6000105542|01/12/2014|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm|scm|vendor|material error|RV leaking on top of SCM|SCM LEAKING RTV
ZF|P7000008275|02/08/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage during transport|ss compl. & w.over xt general|horizontal penetrators|other causes damage|damage during transport|Reprovação do manifold block|unknown info root_cause
ZF|P6000028371|23/01/2008|priority 3 |Q3|SHELL|GOM|NOPT NOTE ATCO NOCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of COV and strainer|DCV/COV with Cobalt pilot ball
ZF|P6000100953|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100031193|25/08/2005|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|design|do not use|scm|scm|vendor audit|unknown info cause_desc|SCM DPR 2500 SN#02|Marginal design
ZF|P6000069056|14/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|assembly|assembled incorrectly|electric products|electrical harness|assy|operator error|Wiring ERROR PowerCan|Opr.fmistake  mixing wiries between SEMs
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #4 Wiring|BPTH SKOFLO SCM SN #4 Wiring
ZF|100036936|05/11/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|test|leakage (fluid)|scm|hydraulic valves|test|operator error|Leakage in HP lines|unknown info root_cause
ZB|100056261|21/12/2009|priority 2 |Q1|MURPHY|WEST AFRICA|NOTE NOCO ATCO|test|function|scm electrical|other scm electrical|other causes damage|damage from wear and tear|SEM Common Alarm|SEM Common Alarm
ZE|P6000064910|25/09/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SGP- MCM Sup Sensor Failure -TEP-SPS-047|unknown info root_cause
ZB|P6000042969|24/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 12|Software improvement/correction
Q3|100016901|09/01/2003|priority 3 |Q3|BP|GOM|NOPT ATCO NOTI NOCO|scm rcm|scm|ext. loc. kos houston|goods receipt|root cause assembly test|workshopassembly test error|Silicone leakage|Zip tie found between outer can & basepl
ZE|P6000120925|26/02/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|SCM MK III -P6000120925|Digital signatures added to MRB
ZF|100020278|01/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|wrong part assembled|scm|scm|vendor|assembly error|Pin not fit|Change pin to smaller one which fits
ZF|100018531|30/09/2014|priority 2 |Q3|SHELL|unknown info region|NOCO NOTE ATCO|marking|marking content error|scm|scm|materials stores|improper packaging & storage|MMR - nonconforming nameplate|unknown info root_cause
Q3|7102643|15/11/1999|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|mechanical|mechanical components|defect locations onshore|workshop|initial direct product problem|function|SCMs  return line bleed nipple loctited|unknown info root_cause
ZF|100020562|18/02/2010|priority 1 |Q3|BP|GOM|NOTE ATCO NOCO NOPT|test|function|scm|scm|intercompany|kongsberg|BPTH SCM 26 Internal PT AI Offset|BPTH SCM 26 Internal PT AI Offset
ZF|P6000058949|19/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|interface issue|scm hyd mech components|check valve|assy|missing parts|Checkvalve on CHKV33-HP is not assembled|Checkvalve on CHKV33-HP is not assembled
ZF|100005667|08/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|change deviation request|process substitution request|scm|scm|other external causes|customer error responsibility|SCM not maintained acc to FMC standards|unknown info root_cause
ZF|100052134|28/06/2006|priority 1 |Q3|PETROBRAS|GOM|NOPT NOCO NOTE|coating|painting defect|scm|scm|vendor|fabrication error|Wrong colour according to spec. SCM 83|Painted incorrect color
ZF|P7000039672|05/09/2018|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|design|dbi error|object types to eng matl class|kits|engineering|ecn change|ECN  7090703    PN  P7000017838|Error-concept/calculation
ZF|3787102|15/03/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|design|procedure error|scm|scm|engineering|continuous improvement|Snorre WCM documentation needs update|unknown info root_cause
ZF|P7000016420|25/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|Desvio no SRT|unknown info root_cause
ZF|P7000039672|01/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|100048038|08/06/2007|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly test|function|scm|scm|vendor|test error|WRONG READINGS ON VERIFICATION TEST|WRONG READINGS DURING TESTING
ZF|P6000065528|04/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|machining|outside diameter error|scm|scm|vendor|specification not followed|blindelokket passer ikke til ytterkanna.|Follow up in ZD QN: 200200917
Q3|7103233|10/04/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOCO NOPT|mechanical|mechanical components|ext. loc. st.johns (canada)|goods receipt|initial direct product problem|function|Crack press. on LP check valve too low|Check valve cracking pressure too low
Q3|7101401|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOTI NOPT ATCO NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upågrade Marlim SCM 04-ALFA to 04-GAMA|Wrong materials
ZF|100025661|05/06/2006|priority 3 |Q3|HOUSTON STOCKING SCM MK II (15K)|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|scm|scm|vendor|test error|RIT Downhole Gauge Test|Test Document Error
Q3|100017305|08/11/2002|priority unknown info priority|Q3|STATOIL|unknown info region|NOCO ATCO NOPT NOTI|scm rcm|scm|defect locations onshore|workshop other|root cause assembly test|workshopassembly test error|Water penetration in SCM at Stackup test|unknown info root_cause
ZF|P6000110380|20/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|dbi error|scm|scm|engineering|engineering error|Trafo assembly|Error in DBI  julia SRM
ZF|7102969|09/05/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|wear & tear|scm|scm|vendor|component error|Broken bolt|Component failure
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|raw material|incorrect material|scm|scm|vendor|material error|Replacement of COV and strainer|DCV/COV with Cobalt pilot ball
ZF|7104075|17/05/2005|priority 2 |Q3|MARUBENI|GOM|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|assy|missing operation|SCM14 failed pt's|RIT failure during refurb of SCM
ZF|P6000122574|09/09/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|assy|operator error|lekkasje under trykktest|Screws assembled in wrong position.
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|project|project requested unfinished shipment|fks quality system issues|quality management system|materials stores|improper handling|Material not delivered to plant|unknown info root_cause
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|marking|marking content error|scm|scm|materials stores|operator error|MIssing batch numbers SCM 02|unknown info root_cause
ZF|100054943|24/10/2007|priority 2 |Q3|WOODSIDE|unknown info region|NOPT NOTE NOCO|assembly test|missed operationassy test|sensors|pressure & temperature transmitter (pt t|assy|operator error|(SS) XT SENSOR TEST NOT PERFORMED|operator error
ZF|P6000098616|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000107981|04/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|physical|scm hyd mech components|other mechanical components|vendor|specification not followed|SCM Nameplate Incorrect|SCM Nameplate Incorrect
ZE|P6000068770|13/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|handle tooling issue|WOCM & SCMs power consumption reading|FMC opr. requested Improvement
ZF|7102969|26/04/2005|priority 3 |Q3|MOBIL EG|unknown info region|ATCO NOTE NOPT NOCO|assembly test|function|scm|scm|engineering|engineering error|solinoid valve function|solinoid valve function
ZF|P6000116166|14/04/2016|priority 3 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|other defect|physical|electric products|electrical harness|other causes damage|planning error|Blank labels were installed on Elec. Cap|Customer requested change
ZF|100020562|22/03/2005|priority 1 |Q3|BP|GOM|ATCO NOTE NOPT NOCO|design|do not use|scm|scm|assy|missing operation|SCM Software Needs to be updated|Design specifications change
ZF|100025661|20/04/2006|priority 2 |Q3|PETROBRAS|GOM|NOCO ATCO NOTE NOPT|assembly test|function|scm|scm|assy|missing operation|CITV not working properly|wiring error
Q1|7103382|11/03/2002|priority 2 |Q1|MELLITAH OIL & GAS  BOURI|unknown info region|NOTI ATCO NOCO NOPT|scm rcm|scm|defect locations offshore field|bouri dp|initial direct product problem|function|SCM 02 Bouri B3-21  AI card malfunction|unknown info root_cause
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|NOCO NOPT NOTE ATCO|assembly test|assembled incorrectly|scm|scm|vendor|assembly error|COMPONENT NOT UP TO CURRENT VERSION|COMPONENT NOT UP TO CURRENT VERSION
Q3|7103233|24/01/2000|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|hydraulic|accumulators|defect locations onshore|workshop other|initial direct product problem|documentation|SCM nitrogen filling equip/PRD required|No KOS procedure for nitrogen filling
ZF|100037428|03/11/2006|priority 1 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly test|function|scm|scm|assy|missing operation|SCM DH gauge error|failure caused by short circuit
Q3|7104670|09/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOTI ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SIO-kort brent ?|unknown info root_cause
ZF|100025661|12/05/2004|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly test|documentation general|scm mech w mb|other scm mechanical|engineering|design specification drawing error| VACUUM TUBE ASSY|Erroneous drawing.
ZF|100068622|12/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|scm el opt components|other el opt components|test|tooling|Not able to perform WGM/MFM test in HFT|No available CPI test equipment.
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|NOTE ATCO NOCO NOPT|assembly test|function|scm|scm|vendor|vendor design error|RS 485 SIMULATOR FUNCTION REQUIREMENT|HFT DOC. & TEST UNIT DISCREPANCY
ZB|100048038|26/05/2010|priority 2 |Q1|CHEVRON|WEST AFRICA|NOCO ATCO NOTE|damage|wear & tear|scm electrical|pressure transducers|other causes damage|damage from wear and tear|PT for PMV failure on AGB 3|PT for PMV failure on AGB 3
ZF|P7000039672|27/02/2018|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|dimension (tolerance)|object types to eng matl class|scm|vendor|specification not followed|Diâmetro da Rosca não conforme|unknown info root_cause
ZF|P6000102687|18/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|engineering|engineering error|Update KS200e SW for Egina|Com. functionality which was not cons.
ZF|P6000088614|27/07/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|machining|thread error|scm hyd mech components|hydraulic manifold adapter plate|vendor|tooling|Threads too tight|Bad edge in beginning of thread
ZF|P6000055605|15/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|marking|marking content error|scm el opt components|scm wiring|other causes damage|cause not found|Wrong wiring PT\TT 3|Wiring error. Cause not found
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOTE NOPT NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #19 Wiring|BPTH SKOFLO SCM SN #19 Wiring
ZB|P6000043122|02/09/2010|priority 2 |Q1|TOTAL|unknown info region|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM SSS 04|Software improvement/correction
ZF|P7000039672|07/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|documentation|missing certificates records|scm|scm|qa qs qi|operator error|Perda da folha do Traceability|unknown info root_cause
ZF|P7000024900|14/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|physical|scm test stand|other mechanical components|other causes damage|planning error|SOLICITAÇÃO DE CONCESSÃO|concessão
ZF|P6000062990|24/06/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|engineering error|Unclear requirements in ECN|Wrong ECN class selected at rev release
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZE|P6000104111|05/11/2018|priority 4 |Q3|TOTAL|WEST AFRICA|OSTS NOTE NOPT NOPR|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|test|other specify in comments|MIV 1 Transmitter P10 Failure (SCM 19)|No failuare found
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|defect types mechanical parts productn|damages|defect locations onshore|workshop other|problem causes defect causes|design|Bytte av solonoider .|unknown info root_cause
ZF|P7000000897|15/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
ZF|P7000024191|02/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|scm|scm|qa qs qi|operator error|SRT não aceito pela inspeção cliente|Documento não marcado como HP
ZF|100052701|25/01/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|marking|no marking|scm|scm|manufacturing|do not use|Top of SCM is not marked  Tøn18|unknown info root_cause
ZF|3794920|19/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|other defect|physical|fks quality system issues|product realization|machine shop personnel|operator error|unknown info notification_desc|proper claning during mobilisation
ZB|P1000004979|29/10/2008|priority 3 |Q1|BP|GOM|NOCO NOTE|damage|damage during transport|scm mech w mb|locking mechanisms|other causes damage|damage during transport|SCM Extension rod Shear pin Failure|SCM Extension rod Shear pin Failure
ZF|P7000001621|26/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm|scm|other causes damage|damage from wear and tear|Furação desalinhada da Hose house|Equipamento retornou do campo
ZF|P7000001621|29/07/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm|scm|machine shop personnel|operator error|Hose House Hercules SN 03|Furação nao casa
ZF|100025661|22/03/2006|priority 2 |Q3|SHELL|GOM|ATCO NOPT NOCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|other causes|no noncompliance|Water in silicon sample after tank test|leak in test equipment - worn seal ring
ZF|P6000076121|19/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|component error|test and transportation|sensor simulator (sesi)|vendor|equipment malfunction|CITV  no connection with module/ST| Equipment Malfunction
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|13/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|component error|instrumentation|scm pressure transmitter|other causes damage|cause not found|PT reading a wrong pressure|3732 Kulite Semiconductor Products  Inc.
ZB|P6000037215|09/11/2010|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|other defect|functional|customer compliant|noncompliance to customer requirement|engineering|engineering error|Warranty Claim # 016- Electrical actuat|Software error
ZF|P7000039672|09/01/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|object types to eng matl class|scm|intercompany|kongsberg|Falha na Comunicação SEM A|unknown info root_cause
ZF|100035118|30/09/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOCO ATCO NOPT NOTE|assembly test|function|scm|scm|engineering|engineering error|Problems with closing commands of SCM|SW timing conflict when 2 SCMs on 1 line
ZF|100052701|14/08/2007|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOPT NOCO|assembly test|dimension (tolerance)|sensors|scm pressure transmitter (pt)|other causes|no noncompliance|Airpocket in epoxy on PT|No non compliance
ZE|P6000147859|24/04/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOPR OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM  Marking Issue|unknown info root_cause
ZF|100046387|06/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|missed operation|scm|scm|test|tooling|CITV and MPFM test in FAT|Lack of functional CPI test equipment
ZF|100031193|11/06/2012|priority 1 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|control valve|other external causes|customer error responsibility|COV LP com vazamento para retorno|Equipamento Reparo
ZF|7104670|26/02/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|project|project requested unfinished shipment|scm|scm|other external causes|customer error responsibility|Company requested NOT perform upgrade|unknown info root_cause
ZF|100050519|27/03/2006|priority 1 |Q3|TOTAL|unknown info region|NOCO NOPT NOTE ATCO|assembly test|function|scm|scm|engineering|engineering error|No proper comm.  with the DHI card|Wiringerror caused cross-talk in comm.
ZF|P6000102554|19/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|specification error|computer system software|sem tpu config|engineering|specification error|Smarttool configuration changes|unknown info root_cause
ZE|100067526|01/09/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|PN 100067526 Drawings and BOM issues|PN 100067526 Drawings and BOM issues
ZF|P6000100953|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100037427|04/07/2011|priority 3 |Q3|TOTAL|WEST AFRICA|NOTE NOCO|test|missed operation|scm|scm|other causes damage|qn cancelled|incorrect rev of procedure is used|Ref QN: 200213490.
ZF|100001156|24/09/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm mech w mb|other scm mechanical|engineering|dwg error|Silicon Leakage on SCM GFS PH2 SN 18|Root cause unknown.
ZF|100017997|18/06/2010|priority 1 |Q3|BP|unknown info region|NOPT ATCO NOTE NOCO|damage|damage from corrosion|scm|scm|materials stores|damage due to corrosion|BPTH IWOCS 4 SCM EC conn. seal surfaces|Probable causes exist  nothing definate.
ZF|P6000068924|25/10/2011|priority 1 |Q3|TOTAL|unknown info region|NOTE ATCO NOCO|documentation|procedure process error|electric products|electrical wire|engineering|procedure error|Wrong use of miniseal|Procedures need update with miniseal use
ZF|100037967|27/06/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|SCM 9  HFT  PRD voltage clarification|Typo in procedure.
ZF|P6000067533|15/08/2011|priority 2 |Q3|KIRINSKOYE SPS|unknown info region|NOTE NOCO NOPT|documentation|incorrect certificates records|scm|scm|other causes damage|qn cancelled|wrong language on GA dwg in sap.|ENG GA DWG is linked in DBI/SAP and TCE
ZF|7104670|14/01/2004|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|service maintenance|unknown info damage_desc|scm electrical|i o pcbs|other causes|miscellaneous|SIO-cards burnt|Specification completed.
ZF|100017997|17/10/2003|priority 2 |Q3|BP|GOM|ATCO NOTE NOPT NOCO|assembly test|function|scm electrical|power supply|engineering|design specification drawing error|Inaccurate readings on SCM PT`s at ETU|Un realistic test
Q1|7105129|31/01/2003|priority 3 |Q1|TOTAL|unknown info region|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations offshore field|pride angola|initial direct product problem|function|SCM 08I Communication checksum error|unknown info root_cause
ZF|P7000008275|04/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|interface issue|scm hyd mech components|hydraulic tubing|test|damaged during testing|Stabs da Outercan empenados|unknown info root_cause
ZF|P7000039672|20/05/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|Leakage out of acceptance criteria PS#62|unknown info root_cause
ZF|P6000069056|28/09/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|marking|marking content error|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|assy|operator error|Cable marking on EC 7 11 & 12 switched| Wrong SCM wiring due to wrong marking
ZF|P6000093498|04/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm hyd mech components|outer can|vendor|specification not followed|Guide pin is not fitting|No freehole for one of the guide pins
ZF|P6000039844|01/10/2010|priority 2 |Q3|SHELL|unknown info region|NOTE NOPT ATCO NOCO|design|specification error|computer system software|basis sw|engineering|engineering error|Wrong dates on Prosedure for SW|unknown info root_cause
ZF|100056918|23/06/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|specification error|computer system software|sw|engineering|engineering error|unknown info notification_desc|unknown info root_cause
ZB|P6000088751|23/09/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|documentation requirement|procedure process error|object types to eng matl class|scm|projects|documentation error|WEL  SCM  L2 escape|unknown info root_cause
Q3|100013155|20/11/2000|priority 4 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|ATCO NOTI NOPT NOCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM test results  customer comments|Minor errors in testing documentation
ZB|100052701|01/12/2010|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|physical|customer compliant|noncompliance to customer requirement|engineering|specification error|Tyrihans Claim 024 COV|COV has too low rating
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|100056261|11/03/2010|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|HFT60033185 Errors|Engineering error
Q1|3801623|04/11/1999|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|hydraulic|hydraulic control valves|unknown info object_part_group_desc_|unknown info object_part_desc_|initial direct product problem|leakage|AWV Control Valve Hyd leak  well C-4H|unknown info root_cause
ZF|7104075|07/06/2006|priority 3 |Q3|SHELL|GOM|NOCO NOPT NOTE ATCO|assembly test|function|scm|scm|vendor|component error|INTERNAL PT FAIL IR TEST|INTERNAL PT FAIL IR TEST
Q3|7104033|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|mechanical|mechanical components|defect locations onshore|inhouse fat|initial direct product problem|material|Manglet O-ring på adpterplate.|unknown info root_cause
ZF|100052134|23/05/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly test|function|scm|scm|other causes|no noncompliance|actual reading not what procedure wants|Accept Assembly For Use
Q1|7101172|08/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|Refurbishment of SCM|Refurbishment
ZF|P7000039672|16/02/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|leak|object types to eng matl class|scm|test|incorrect set up testing|SCM - Vazamento Adapter Plate LP|unknown info root_cause
ZE|P6000028371|08/06/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm electrical|processor pcbs|causes for improvement|lack of training|Z Impact for software|unknown info root_cause
ZF|100056261|27/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Revise Test Procedure|HFT  Procedure HFT 60033185/D
ZD|7102969|20/09/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|coating plating|coating defect|scm hyd mech components|baseplate|vendor|coating defect|Incorrect coating|unknown info root_cause
ZF|100049000|15/07/2011|priority 3 |Q3|BP|GOM|NOTE ATCO NOCO NOPT|machining|false cut|scm|scm|vendor|programmer error|Dial caliper coupler measurements|Dial caliper coupler measurements
ZD|100049000|11/02/2006|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|marking|no marking|scm|scm|vendor|fabrication error|MARKING|Revision Letter Not On Part
Q3|7104075|26/04/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|electrical|sem el.rack|ext. loc. kos houston|work shop|initial direct product problem|function|Failure in supply voltage|unknown info root_cause
ZB|100068622|11/06/2014|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|functional|scm|scm|engineering|procedure error|Warranty claim 264-Unable to turn power|unknown info root_cause
ZF|P6000109984|24/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|interface issue|scm|scm|engineering|engineering error|Interface issue for top plate|Wrong top plate specified in BOM
Q1|7101172|unknown info defect_date|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|product defects for dept.|scm|defect locations offshore field|gullfaks a|root cause engineering|design specification error|Pressure drop when PMV or PWV operated|Design - restrictors to be introduced
ZF|100052134|14/07/2006|priority 3 |Q3|PETROBRAS|GOM|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|vendor|test error|WRONG SEM B DHI ADDRESS INDICATED ON SCM|Wrong SEM B Address
ZF|7100320|22/04/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO|assembly|physical damage|scm|scm|test|damaged during testing|MMR - Broken fitting Outer Can|unknown info root_cause
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO NOTE NOPT ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 01|Software improvement/correction
ZB|100056176|15/12/2009|priority 1 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|other defect|functional|customer compliant|noncompliance to customer requirement|projects|free issue delivery|Warranty Claim 182 Loss of comm DHI 119|Customer Provided Item
ZF|P7000008275|27/08/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|electronic boards|other eletronic boards|other causes damage|cause not found|Problem With APSD1 - P6000020498|unknown info root_cause
ZF|P7000039672|28/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|physical damage|scm hyd mech components|other mechanical components|vendor|final inspection error|Parafuso cisalhado|124086 PARNOX IND E COM DE ARTIGOS IND L
ZF|P7000024900|10/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm el opt components|trafo unit|intercompany|kongsberg|Transformer no conformably|unknown info root_cause
ZF|P6000116166|03/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm|scm|assy|operator error|Drops of water in the silicon sample|SCM not cleaned before silicone filling
ZF|100030542|19/09/2005|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly test|do not use|scm|scm|assy|operator error|SCM Procedures Have Not Been Followed|Procedures not followed
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|hydraulic|hydraulic control valves|defect locations onshore|montasje|initial direct product problem|material|Refurbishment  Bytting av solenoider|unknown info root_cause
Q3|7102643|05/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM  int/ext sensors failed SEM A  N-4H|Not yet known
Q3|100005667|02/02/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|mechanical|outer can|defect locations onshore|workshop other|initial direct product problem|documentation|Åsg SCM 32  12 pin con. marking missing|KOS dwg does not give enough infomation
ZE|P6000122626|09/07/2018|priority 3 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM  Updates to Agbami 615 Test procedur|unknown info root_cause
ZB|100016711|06/01/2010|priority 2 |Q1|BP|GOM|NOTE NOPT NOCO ATCO|raw material|defects in material|scm mech w mb|locking mechanisms|other causes damage|damage from wear and tear|Lock Dog Separated From Locking Mech|Lock Dog Separated From Locking Mech
ZF|P6000105542|06/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm sem el opt component|sem cable & wiring|test|damaged during testing|Voltage dropped in SEM ESS vibration tst|Bad connection at CFG Faston contact J63
ZF|P6000105542|27/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|object types to eng matl class|scm|test|missed operation|Unable to perform test according to HFT|unknown info root_cause
ZF|3787102|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|100055762|19/05/2008|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|marking|unknown info damage_desc|scm|scm|engineering|engineering error|SCM material/documentation discrepancies|unknown info root_cause
ZF|P6000088604|26/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm hyd mech components|check valve|test|operator error|Bench vise marks on LP & HP Check valves|Wrong use of bench wise
ZF|100055762|23/04/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|other causes damage|no noncompliance|Batch numbers missing|QC change to batch management
Q3|7104670|15/09/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|scm rcm|scm|defect locations offshore field|heidrun tlp|initial direct product problem|function|XT / SCM / TH lines blocked without expl|unknown info root_cause
ZF|100017278|13/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|coating plating|coating defect|scm|scm|other external causes|customer error responsibility|Urgent repair of SCM|Customer approved deviation
ZF|7101463|21/03/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|design|procedure error|scm|scm|engineering|procedure error|procedure not correct per testing|procedure not correct per testing
Q3|7101172|19/06/2001|priority 4 |Q3|STATOIL|NORTH SEA|ATCO NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|HT PT under reads 79 bar on A & B|Not known
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|100048038|25/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|drawing error|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|Agbami tubing issues|See DRM60116544
ZB|P6000043122|06/01/2010|priority 3 |Q1|TOTAL|WEST AFRICA|NOCO NOTE NOPT|test|missed operation|scm|scm|test|missed operation|Punch List SCM SSS 03|Missed operation/procedure not approved
ZB|100017997|01/03/2010|priority 2 |Q1|BP|GOM|NOTE NOPT NOCO ATCO|raw material|hardness out of tolerance|scm mech w mb|outer can|other causes damage|damage from wear and tear|Roughness out of tol. on EC face seal|Roughness out of tol. on EC face seal
ZF|P6000121393|18/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|damage|damage during assembly|scm hyd mech components|check valve|vendor|specification not followed|Over torqued Check Valve|Damaged at supplier  sent to FMC
ZB|100020278|26/11/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE|test|component error|scm|scm|vendor|equipment malfunction|08-MEGI-012: AIB Voltage Reference Error|SEM B-Voltage Ref Error
ZF|P6000122574|04/12/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|missed operation|object types to eng matl class|scm|test|operator error|SCM received with accumulator @ 120bar|Accumulators not bleed off
ZB|100001156|06/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE|test|function|scm|scm|other external causes|customer error responsibility|Guarantee claim 131 - Failure on sensors|Unknown reason for failure
ZB|P6000105542|22/01/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|other defect|functional|scm|scm|other causes damage|cause not found|Gullfaks GSO claim 294 SCM RandPT SUBSEA|Equipment installed  need investigation
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000042969|13/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|red hydraulic dust caps left on XT|Red protector Caps lef on SCMMB
ZE|P6000055605|08/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|improve records in MRBs for Shell|records not placed in prod reports
ZF|P6000088614|11/11/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE ATCO NOCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM MAN/SIV 03|Software improvement/correction
ZF|100035118|23/09/2016|priority 2 |Q3|WOODSIDE|unknown info region|ATCO NOCO NOTE|test|damaged during testing|scm hyd mech components|control valve|test|incorrect set up testing|High return pressure on HP|Return line not connected.
ZF|P7000008275|01/10/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|other external causes|customer error responsibility|Lack of o'ring groove on segments|unknown info root_cause
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTI NOPT NOCO|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|function|Bytte solonoider på ventiler.|unknown info root_cause
Q3|100018082|08/07/2002|priority unknown info priority|Q3|STATOIL|NORTH SEA|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|efat|root cause vendor|material component error|HYDRAULIC RETUR PT27 SHOWS 50BAR BY 0BAR|unknown info root_cause
Q3|7104075|05/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|electrical|pressure transducer|defect locations onshore|workshop other|problem causes defect causes|repair|SHE SCM 01  change PTs  mod. of DHI-108|unknown info root_cause
ZF|100049000|31/08/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|interface issue|scm el opt components|el. connector|other causes damage|qn cancelled|unknown info notification_desc|QN made 2 times see QN 200176570
ZF|100048038|12/04/2007|priority 2 |Q3|AGBAMI|unknown info region|ATCO NOCO NOTE NOPT|assembly test|function|scm|scm|other external causes|customer error responsibility|LP pressure changes AGB SN 24|New requirements from customer
ZB|P6000039844|20/09/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Shell GK_ SCM#24_ Routine maintenance|unknown info root_cause
ZE|P6000101955|06/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|capture mistake|SCM nameplate SN digits not match body|Wrong S/N marking on outecan  corrected
ZF|100034629|09/02/2005|priority 3 |Q3|STATOIL|unknown info region|NOCO ATCO NOPT NOTE|assembly test|do not use|scm|scm|assy|operator error|High pressure against SCM P/N 100034629|SCM LP supply overpressurised.
ZB|P6000077632|11/12/2015|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|electrical|other specify in comments|scm sem el opt component|other scm sem el opt components|electrical|other specify in comments|Block 18 BP SCM #401 SEMA no comm|SEM not communicating
ZF|100017997|29/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring fault CVLP 18|Wiring inside SCM wrong.Wiring switched.
ZF|P7000024191|04/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|physical damage|scm hyd mech components|outer can|materials stores|damaged during transport|Parafuso não monta na Outer Can..|unknown info root_cause
ZB|100036936|20/10/2014|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|other defect|functional|electronic boards|power units|test|operator error|Lack of communication between Norne-DSB|Human error
ZF|P6000103208|05/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|HP supply flowmeter is counting wrong|Flowmeter not counting at minimum flow
ZF|100049000|11/04/2006|priority 3 |Q3|BP|unknown info region|NOPT NOTE NOCO ATCO|design|user documentation procedures|scm|scm|engineering|engineering error|HFT DISCREPENCY|HFT Instructions Issues
ZF|P7000016420|13/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly|assembled incorrectly|hydraulic products|other hydraulic products|assy|operator error|Conector e back shell danificado.|Danificado na montagem
ZB|100056261|29/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|NOTE ATCO NOCO|test|function|scm electrical|other scm electrical|test|damaged during testing|SEM Common Alarm|SEM Common Alarm
ZF|P6000031350|18/11/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|procedure process error|scm|scm|other causes damage|qn cancelled|MPR60036199 does not exist|linked to DBI but not released-use EPLAN
ZB|100025661|31/07/2008|priority 3 |Q1|SHELL|GOM|NOPT NOTE NOCO ATCO|test|function|scm electrical|i o pcbs|vendor|equipment malfunction|LLANO2 SCM 49 Line B AI card faulted|LLANO2 SCM 49 Line B AI card faulted
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZD|P6000074156|13/03/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|documentation|missing certificates records|vendor quality system issue|quality management system|vendor|specification not followed|ATS-Missing Documentation|DRL-0000020085  DRL-0000020034
ZF|P7000016420|17/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm hyd mech components|sem bracket|vendor|specification not followed|Montagem da eletrônica na bracket|MERCOTUBOS
ZF|100056261|08/01/2008|priority 3 |Q3|MURPHY|WEST AFRICA|NOTE NOPT NOCO|documentation|missing certificates records|scm|scm|other causes|no noncompliance|batch missing|unknown info root_cause
ZF|3801623|18/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZB|P6000074156|17/07/2017|priority 3 |Q1|SHELL|unknown info region|NOTE ATCO NOCO|design|specification error|object types to eng matl class|scm|test|tooling malfunction|Shell  SCM 419  NCR #17|unknown info root_cause
Q3|7105128|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTI|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM General|unknown info root_cause
ZF|100048038|26/03/2007|priority 1 |Q3|CHEVRON|WEST AFRICA|ATCO NOTE NOCO NOPT|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 21|Damage in warehouse handling
ZF|100025661|02/09/2005|priority 3 |Q3|SHELL|GOM|NOPT NOTE NOCO ATCO|assembly test|missed operationassy test|scm|scm|assy|missing operation|NO TEST SPECIFICATION LISTED ON DBI|NO TEST SPECIFICATION LISTED ON DBI
ZF|P6000100953|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|machining|thread error|scm hyd mech components|outer can|engineering|engineering error|Threads in outercan to short|Interface with EC adapter not verified
Q3|7104033|17/01/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|electrical|sem el.rack|defect locations onshore|workshop other|initial direct product problem|documentation|El rack koblingsfeil på module.|unknown info root_cause
ZF|P6000042308|03/07/2009|priority 4 |Q3|TULLOW|WEST AFRICA|NOTE NOCO ATCO|change deviation request|conversion approval|scm|scm|other causes damage|no noncompliance|Alternate hydraulic fluid SCM test|Alternate Hydraulic Fluid SCM Test
ZF|P6000093498|09/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring fault|Wiring error found in screening  no RCA
ZF|P6000064910|20/07/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Power wiring to SEM A and B was crossed|Wiring error by operator
ZF|3812476|18/12/2008|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|test|unknown info damage_desc|scm|scm|test|unknown info cause_desc|HFT on SCM has not been done|HFT not performed
ZF|P6000102554|30/06/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|coating plating|painting defect|scm|scm|vendor|coating defect|Top plate discolored.|Discoloration after hyperbaric  accepted
ZF|P6000063531|27/12/2010|priority 1 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
Q1|7100320|27/02/2002|priority 3 |Q1|PETROBRAS|unknown info region|NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|cleanliness|LP filters coated  white/blue substance|Hyd fluid contaminated?
ZF|100048038|14/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT NOCO|marking|no marking|common misc fasteners imperial|screw|engineering|engineering error|Batch missing|New requirements
ZF|P7000008275|25/08/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Cisalhamento do Filter for Compensator|Overtorque
Q3|100016110|04/04/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|hydraulic|hydraulic control valves|ext. loc. kos houston|work shop|root cause assembly test|workshopassembly test error|Ceramic control valve in wrong position|unknown info root_cause
Q3|100001156|24/02/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|All SCMs to have hyd. flow restrictors|Instructions from system engineering
ZB|100020562|20/01/2010|priority 3 |Q1|BP|GOM|NOCO NOTE NOPT ATCO|test|leakage (fluid)|scm hydraulic|other scm hydraulic|other causes damage|damage from wear and tear|Leaking LP Changeover valve|Leaking LP Changeover valve
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOPT NOCO NOTE|design|dbi error|scm hyd mech components|other mechanical components|engineering|specification error|Wrong Bill Of Material and wrong parts|Coupler Interface on m.block (spc error)
ZF|P6000064909|30/06/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|damage during assembly|scm test stand|other el opt components|vendor|specification not followed|CAT5 Ethernet coupler damaged|CAT5 ethernet coupler damaged
Q3|7103233|26/11/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|electrical sensor equipment|electrical pin connetors|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|SCM modified due to fault in Tub. Hanger|Tub. Hanger DHPTT pins cross connected
ZF|P7000024900|14/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm el opt components|el. connector|qa qs qi|goods receiving inspection error|EC without O`rings and guide pin|unknown info root_cause
ZF|P6000037215|26/10/2010|priority 3 |Q3|ENGIE|NORTH SEA|NOCO ATCO NOTE|other defect|functional|electric products|other electric products|engineering|engineering error|Gjøa - El. Act. charging problem|Software bug
ZF|P7000039672|16/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|physical damage|common misc fasteners metric|bolt|assy|manufacturing engineer erorr|Cabeça do parafuso roletada durante mont|unknown info root_cause
ZF|P7000039672|06/04/2016|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|O'ring desconforme|Desvio não pertinente
ZF|P7000000897|17/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|coating plating|incorrect colour coating|scm hyd mech components|locking mechanism|qa qs qi|goods receiving inspection error|Revestimento|unknown info root_cause
ZF|100052231|21/12/2006|priority 2 |Q3|CHEVRON|GOM|ATCO NOCO NOPT NOTE|assembly test|do not use|scm|sem|vendor|component error|SO due to DC/DC Issue on AI150 card|Component Failure/Poor Workmanship
ZD|100020562|01/09/2010|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|design|material master error|scm|scm|vendor|material error|Sealing Surface error|Sealing Surface error
Q3|100018600|06/02/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause engineering|other product design error|Rewiring of EC15 on all SCM's|unknown info root_cause
ZF|100035013|19/01/2009|priority 2 |Q3|SHELL|unknown info region|ORAS NOTE ATCO NOCO|test|function|scm|scm|test|operator error|Cannot operate MDV on XT|Lack of training - failed to refit plate
ZF|P6000079032|22/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|assembled incorrectly|electric products|electrical harness|engineering|engineering error|Fixes|Std wire length too short-Need extension
ZF|100068622|09/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|coating plating|coating defect|scm hyd mech components|outer can|other causes damage|damage from wear and tear|Coating on outer can|wear and tear
Q3|3812476|05/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations onshore|fks adm.|root cause engineering|material fault|SCM10 NORNE upgr.DHI107/LP-Accu/PMV-sol.|unknown info root_cause
ZF|100052701|08/02/2008|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE|marking|marking content error|scm|scm|materials stores|operator error|MIssing batch numbers SCM 01|unknown info root_cause
ZD|100049000|13/12/2006|priority 1 |Q2|BP|unknown info region|NOCO NOPT ATCO NOTE|assembly test|function|scm|scm|vendor|component error|INTERNAL PT FAILED ON SCM|P/T FAILURE
ZF|100018531|09/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm hyd mech components|control valve|other causes damage|damage from wear and tear|leakage teste failure| Equipment in use for four years
ZF|P6000080343|12/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|assy|operator error|Leakage from CVLP24 and CVHP55|too much loctite on bolts caused leakage
ZF|100030542|16/01/2008|priority 3 |Q3|BAOBAB ADD. XT P11/P12|unknown info region|NOPT NOTE NOCO|documentation|incorrect certificates records|scm|scm|other causes|no noncompliance|Batch numbers missing in iBASE list|Change: batch cert. to batch management
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|product defects for dept.|scm|defect locations onshore|workshop other|initial direct product problem|material|Bytting solenoider på ventiler.|unknown info root_cause
ZF|100017278|26/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|design|drawing error|scm hyd mech components|compensator|other causes damage|qn cancelled|Wrong item ref. in DWG-020442-004|No DWG error found.
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|defect types mechanical parts productn|function|defect locations onshore|workshop other|problem causes defect causes|production control|Bytte av solonoider på ventiler.|unknown info root_cause
Q3|3787102|05/04/2002|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations onshore (hes)|kongsberg a b|initial direct product problem|leakage|Silicone in Return line on SCM.|unknown info root_cause
ZF|P6000069056|07/03/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE|machining|slot error|scm hyd mech components|outer can|vendor|specification not followed|Drain holes for outercan not acc to dwg|Outercan not produced acc to DWG
ZF|P7000000229|24/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|coating plating|painting defect|ss compl. & w.over xt general|electrical connection systems|paintshop|operator error|Revestimento|Espessura acima do especificado
ZE|P6000039844|28/06/2011|priority 2 |Q3|SHELL|unknown info region|NOTE ATCO NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|(SS) Improvement to SCM RIT Procedure|No section to record the software versio
Q1|7101172|03/06/2002|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|SCM GFA 09 Wellhead temp. SEM B malfunct|unknown info root_cause
ZF|100035118|10/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|damage|damage during transport|scm|scm|other external causes|customer error responsibility|Incorrect Transport and Handling of SCMs|Shipment packed and coordinated by Compa
ZF|P6000063633|07/07/2011|priority 3 |Q3|ENI|unknown info region|ATCO NOCO NOTE|test|missed operation|scm|scm|assy|operator error|incorrect rev of procedure is used|Incorrect rev of filling procedure used.
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|NOPT NOTE ATCO NOCO|assembly test|interface of components issue|scm|scm|vendor|vendor design error|Conflict between strainer and SCMMB|Conflict between strainer and SCMMB
ZF|100036232|24/04/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|component traceability not maintained|scm hyd mech components|control valve|documentation requirement|process step not followed detected|Missing SEM equipment in structure list|SEM equipment not put in structure list
ZF|P6000088604|16/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|interface issue|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000042969|25/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 15|Software improvement/correction
ZF|P6000103208|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7103234|16/02/2001|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTI|electrical|pressure transducer|ext. loc. kos houston|work shop|root cause vendor|design error|SCM PTs to be upgraded/tested|Supplier design error
ZF|100056443|01/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|test|function|electronic boards|dhi|vendor|operator error|Troll SCM#4 SEM A DHI204 Current Reading|WD calibration data accidentally deleted
Q3|100001156|05/11/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations offshore field|deepsea trym|initial direct product problem|function|SCM SEM A  no comms with DHPG. SEM B ok|Not yet known  SCM still subsea
ZF|100035400|16/08/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|FAIL DISCOVERED DURING TESTING OF CITV|unknown info root_cause
ZF|P6000055605|08/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|component error|hydraulic products|other hydraulic products|vendor|specification not followed|Increase in pressure on PT 18|Followed up in QN 200421055
ZB|100048038|14/02/2009|priority 3 |Q1|CHEVRON|WEST AFRICA|ATCO NOCO NOTE|test|function|control system topside hydraulic eq.|hydraulic power unit (hpu)|other causes damage|damage from wear and tear|circulations pump failure due to degrade|circulations pump failure due to degrade
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 07|Software improvement/correction
ZF|P6000108984|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm hyd mech components|outer can|other causes damage|no noncompliance|Threads on outercan to short|Interface with EC adapter verified OK
ZF|100037967|25/01/2006|priority 1 |Q3|BP|unknown info region|NOTE ATCO NOCO NOPT|assembly test|assembled incorrectly|scm|scm mounting base (scm|materials stores|improper handling|Wrong baseplate assembled on SCM|failure of routine by new personnel
ZB|100001156|18/05/2005|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|ss compl. & w.over xt r. tools|xmas tree running tool for cxt|materials stores|operator error|2 L-4H GFC AI card SEMA malfunct.|Failure in AI Card
Q3|3812476|06/02/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTI|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|function|SCM to be upgraded|unknown info root_cause
Q3|7102643|20/03/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations offshore field|åsgard a|initial direct product problem|function|SCM PT incorrect reading of valve status|Not yet known
ZB|100048038|13/12/2007|priority 2 |Q1|CHEVRON|WEST AFRICA|NOCO NOTE|assembly test|function|scm electrical|other scm electrical|vendor|component error|NO COMMUNICATION WITH A SIDE ADDRESS|unknown info root_cause
ZF|100046112|14/10/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOCO NOPT ATCO|assembly test|assembled incorrectly|scm|scm|assy|operator error|WRONG WIRING OF EC|Incorrect wiring.
ZF|100056176|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|project|project requested unfinished shipment|fks quality system issues|resource management|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|P6000042308|07/05/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|unknown info damage_desc|scm|scm|other causes damage|no noncompliance|Oversized holes for config. plugs|Non-Compliance handled in Qn 200117134
ZE|P7000016420|15/10/2018|priority 2 |Q3|PETROBRAS|unknown info region|OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|p7000016422 2018-04-09 pdg do ro-168 não|unknown info root_cause
ZF|3794920|04/07/2007|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|assy|unknown info cause_desc|SENSOR PT ANN NO READINGS ON ETU|SCM was repaired
ZF|7104075|25/10/2005|priority 3 |Q3|MARUBENI|GOM|ATCO NOCO NOPT NOTE|assembly test|function|scm|scm|vendor|component error|FAILURE TO MEET ACCEPTANCE CRITERIA|Component failure
ZF|100020562|22/07/2009|priority 3 |Q3|BP|GOM|NOCO NOTE ATCO NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|SKOFLO SCM SN #1  Wiring|SKOFLO SCM SN #1 Wiring
ZF|P6000076121|03/10/2011|priority 3 |Q3|CNOOC|unknown info region|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|other causes damage|cause not found|PT outside accept criteria|Cause not found  QN200236529&QN200239524
ZF|P6000083428|10/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|change deviation request|part substitution request|scm hyd mech components|hydraulic coupler|engineering|continuous improvement|HC72 to be replaced with blind coupler|BOM needs update. Wrong PN on HC72
ZF|P6000055605|22/06/2011|priority 3 |Q3|SHELL|GOM|NOPT ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring mistake on EC 7|Human Error
ZF|100020562|25/06/2004|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PT/TT  Simulator is not working|unknown info root_cause
ZE|100035119|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Enfield - SCM Issue|Enfield - SCM Issue
ZF|P6000069056|06/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No failure detected in extended testing
ZF|100018082|11/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|qa qs qi|documentation error|Wrong ref. in FAT for Mikkel SCM|Wrong ref. in FAT for Mikkel SCM
ZF|P7000000897|12/11/2015|priority 3 |Q3|SHELL|unknown info region|NOTE NOPT ATCO NOCO|coating plating|coating defect|scm hyd mech components|outer can|other external causes|customer error responsibility|MMR - Coating Refurbishment|unknown info root_cause
ZE|100035119|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Enfield - SCM Issue|SCM Issue
ZF|P6000103208|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q1|7102643|28/08/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI ATCO NOPT NOCO|hydraulic|hydraulic control valves|defect locations offshore field|transocean searcher|initial direct product problem|leakage|SCM 35  Well R-1H Hyd. leak HP circuit|unknown info root_cause
ZB|7102969|21/03/2007|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|damage|damage from corrosion|scm electrical|rov el. connectors|other causes|logist.handling packing shipping error|Electrical Flying lead stuck on SCM Elec|Follow procedures and process
Q3|7101172|21/09/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|hydraulic|hydraulic control valves|defect locations offshore field|gullfaks a|initial direct product problem|leakage|SCM hydraulic leak  21-95 l/d  well F-4H|See QN 200008814
ZF|100037427|30/09/2005|priority 1 |Q3|TOTAL|WEST AFRICA|NOTE NOPT ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Return compensator retest SCM I02|unknown info root_cause
ZF|100034629|15/09/2004|priority 3 |Q3|STATOIL|unknown info region|ATCO NOPT NOTE NOCO|assembly test|dimension (tolerance)|scm mech w mb|one atmosphere canisters|engineering|design specification drawing error|EL. CAN IS STUCK|unknown info root_cause
Q3|7104033|24/02/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|All SCMs to have hyd. flow restrictors|Instructions from system engineering
ZE|100056918|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|ENFIELD- SCM Fault|SCM Issue
ZF|7102643|02/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|damage|wear & tear|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|Wear and tear.
ZF|P6000093501|07/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000132097|13/12/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|conversion approval|object types to eng matl class|press_temp_transmitter|other causes damage|cause not found|SIIS level 2 flying master|unknown info root_cause
ZF|100031223|04/08/2006|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|assembly test|leakage (hydraulic air nitrogen etc.)|scm|hydraulic valves|assy|missing operation|Leakage in hydraulic coupler.|unknown info root_cause
ZD|P6000088751|14/02/2016|priority 4 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|procurement|part not protected as per dbi|scm|scm|assy|missing parts|GWF/Missing protection cap|unknown info root_cause
Q3|7101172|08/11/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|function|SCM upgrades after removal of outer can|unknown info root_cause
ZD|100020278|06/05/2010|priority 3 |Q2|EXXONMOBIL|unknown info region|ATCO NOPT NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|Megi 35|Procedure Concerns
ZF|7104075|12/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|procedure error|scm|scm|other causes damage|no noncompliance|SCM filter change document conflict|SCM filter change document conflict
ZF|100046112|15/11/2011|priority 1 |Q3|WOODSIDE|unknown info region|NOPT NOCO NOTE ATCO|damage|damage during testing|electronic boards|dhi|vendor|operator error|(SS) MMR- DHI109 board found burnt|DHI 109 board found burnt capacitor
ZB|P6000064909|02/04/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|specification error|customer compliant|unsatisfactory customer satisfaction|engineering|specification error|LT NCR 25: SCM Software|unknown info root_cause
Q3|7101172|10/04/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTI ATCO NOCO|scm rcm|scm|defect locations offshore field|gullfaks a|initial direct product problem|function|Possible defect 4-20mA interface SEM A|AD Converters too old rev. on AI150 card
ZF|P6000104111|13/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|design|specification error|computer system software|sem tpu config|engineering|specification error|SEM taking too long to get communication|unknown info root_cause
ZF|P6000042969|22/10/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|engineering|dbi error|HC 51 is leaking oil|Design error  will be repaired in ZD QN
ZF|P6000105542|13/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|function|electronic boards|comm.link (power line)|other causes damage|cause not found|MRMS on Line A not working|SCM to be returned to KBG for repair
ZF|P7000024900|17/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Connectors inverted|unknown info root_cause
ZF|100029062|09/03/2011|priority 1 |Q3|TOTAL|unknown info region|NOCO NOPT ATCO NOTE|test|function|scm sem el opt component|other scm sem el opt components|vendor|programmer error|Hydraulic test on SCM Prod 07 failed|Sensor reading failled
ZC|100036936|22/04/2005|priority 2 |Q2|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|assembly test|do not use|fks quality system issues|resource management|assy|missing operation|Not performed HFT do to lack of time|PSM not followed  short mob time
ZB|7101172|18/03/2009|priority 4 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO|damage|wear & tear|scm|hydraulic valves|other causes damage|damage from wear and tear|SCM 25  GFA D-1H  LP int.leak PWV &SCSSV|Leakge in SOV
ZF|100037130|17/12/2004|priority 1 |Q3|BOURI  FEAD|unknown info region|NOPT NOTE NOCO|assembly test|function|scm hydraulic|other scm hydraulic|engineering|procedure error|Too high cracing pressure on check valve|Cracing pressure not verified on SCM
ZF|100050519|03/07/2006|priority 3 |Q3|MOHO BILONDO|unknown info region|ATCO NOPT NOTE NOCO|assembly test|assembled incorrectly|scm|scm|assy|lack of training|DHI values on wrong index on ETU|failure to follow procedures
ZD|100034440|10/09/2005|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|do not use|scm|scm|vendor|fabrication error|Missing Documentation|Documents errors
ZF|100026328|22/05/2003|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOPT NOTE|assembly test|material faulty|scm electrical|wiring|engineering|design specification drawing error|FAIL WITH EL. CARD|Missing wiring connection.
ZF|7102969|07/03/2006|priority 3 |Q3|EXXONMOBIL|unknown info region|NOTE NOPT ATCO NOCO|assembly test|function|scm|scm|vendor|component error|FAILURE TO OPPERATE TO PRD REQUIREMENTS|SILICONE CHECK VALVE FAILURE
ZD|P6000039844|06/11/2009|priority 1 |Q2|SHELL|unknown info region|NOTE NOCO NOPT|marking|marking content error|scm|scm|vendor|specification not followed|(SS) Wrong Marking on SCM|unknown info root_cause
ZB|100036936|19/02/2009|priority 4 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|test|component error|scm|scm|other causes damage|damage during transport|F&D Not possible to communicate SEM A-B|SCM did not work as intended
ZF|100020562|31/10/2005|priority 2 |Q3|BP|GOM|NOTE NOCO NOPT ATCO|damage|damage during testing|scm|scm|other causes|logist.handling packing shipping error|DAMAGE TO EC7 ELE CONNECTOR|EC7 CONNECTOR DAMAGED
ZE|P6000069056|04/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|computer system software|sem tpu config|causes for improvement|documentation|Wrong config shown in Software document|Error in document LST60062051  rev A
ZD|P1000004979|10/08/2005|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly test|function|scm|scm|vendor|vendor design error| SCM Software|Software design parameters
Q1|7103233|13/03/2003|priority 3 |Q1|SUNCOR NGXT|unknown info region|NOPT NOTI NOCO|hydraulic|flowmeter|ext. loc. st.johns (canada)|work shop|initial direct product problem|function|SCM 08P TNO SEMB LP Ret. malfunction|unknown info root_cause
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOCO NOTE|design|specification error|scm|scm|engineering|continuous improvement|Gluing of DHI212 board|WD design improvement.
ZF|P6000058949|14/09/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|function|scm|scm|test|operator error|Feil luping  fra Hp til Lp|Not correct marking on test equipment
ZF|P6000088614|14/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|interface issue|scm sem el opt component|sem mech. components|vendor|specification not followed|To small holes in the wedge disk|Hole size error  follow-up QN200377517
ZF|P6000104116|27/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|Not completed threads  DIU16|Unfinished threads
ZB|100026328|11/05/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|physical damage|scm|scm|other external causes|customer error responsibility|Viola Claim 001 SCM #07|Suspect failure at CBV.
ZF|P6000083428|13/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000063531|27/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZE|P6000076121|05/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|LH4-1 E1 SCM voltage high|E1 SCM voltage high
Q3|7104075|19/09/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTI|hydraulic|hydraulic coupler|defect locations onshore|workshop other|root cause engineering|design specification error|EXCHANGE HYD COUPLERS PRIOR TO HYP.TEST|unknown info root_cause
ZF|P7000039672|04/02/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|missed operation|scm|scm|test|missing parts|Ausência dos printout - Ctrl valve reset|unknown info root_cause
ZF|P6000093498|29/07/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|scm|scm|engineering|engineering error|Missfitting el-can for SUPS|Housing SEM620 selected not SUPS housing
ZF|P6000088626|19/07/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|marking|marking content error|scm|scm|marking|incorrect marking|Traceability miss match  non complience|CER-0000020742 has wrong SN
ZF|100006609|06/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|physical|scm hyd mech components|outer can|assy|missing operation|PARAFUSO NÃO TORQUEADO CORRETAMENTE|unknown info root_cause
ZF|P7000001621|29/05/2018|priority 4 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTE|damage|damage during assembly|object types to eng matl class|scm_components|assy|damaged during assembly|MMR - Compensator Bladder Leakage|unknown info root_cause
ZB|7106268|05/07/2004|priority 2 |Q1|TOTAL|unknown info region|ATCO NOPT NOCO NOTE|assembly test|function|scm el. act.syst|control electronics|vendor audit|unknown info cause_desc|SCM 02 I/WDHI SEM A no comunication|Jumper not properly connected..
Q3|7102643|17/10/2000|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM upgrades after removal of outer can|unknown info root_cause
ZF|100020278|20/01/2011|priority 2 |Q3|EXXONMOBIL|unknown info region|NOTE ATCO NOCO NOPT|documentation|procedure process error|electric products|electrical components|intercompany|houston|Missing Sign offs|Missing Sign Offs
ZF|100030542|09/10/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly test|assembled incorrectly|scm|scm|assy|operator error|SCM Plug is wrongly installed|Part can be used as installed.
Q3|7100320|12/12/2001|priority 3 |Q3|PETROBRAS|unknown info region|NOTI NOCO NOPT|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|function|SCM 15 Hercules Extension rod defect|unknown info root_cause
ZF|P6000051036|01/06/2010|priority 2 |Q3|BP|unknown info region|NOTE NOCO|documentation|incorrect certificates records|scm|scm|qa qs qi|documentation error|Manifold block redirected to Germ SCM 02|redirection of m.block due to logistics
ZF|P6000065886|15/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|design|dbi error|scm|scm|engineering|dbi error|Compensator assy fault|BOM error
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|machining|angle error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100049000|05/03/2009|priority 3 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|marking|marking content error|scm|scm|vendor|assembly error|Address Error on Nameplate|SEM Address Error on Nameplate
ZF|100046112|23/11/2005|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOCO NOPT ATCO|assembly test|interface of components issue|scm|scm|other causes|do not use|Wrong interface-debris cap and test hose|Interface problem test equipment / SCM
Q3|3794920|03/02/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|electrical|modems communications|defect locations offshore field|viking poseidon|initial direct product problem|function|No contact with SCM sensors  offshore|No fault found at KOS KBG  SCM re-sent
ZF|P7000024900|15/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|other defect|physical|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|cause not found|Scratches on Adapter Plate for cvlp|Scratches on Adapter Plate for cvlp
ZF|100035013|17/12/2008|priority 2 |Q3|SHELL|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|assy|operator error|cannot seal outer can to SCM|metal debris left in the o-ring groove
ZB|P6000080733|14/05/2014|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|functional|scm|scm|projects|material error|Fram H Nord Claim SCM 02|Break in connection
ZF|P6000125392|13/05/2017|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation requirement|incorrect user documentation (customer)|object types to eng matl class|scm|documentation requirement|procedure error|HFT for ROSA SCM is wrong|Error in HFT  Inhouse and FAT.HP supply pressure to high
ZD|P6000068912|30/07/2013|priority 2 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|marking|no marking|scm test stand|hydraulic couplers|intercompany|kongsberg|Missing Valve Cap P/N:100014108 from SCM|Missing Protection Cap
ZF|P6000104111|20/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100020562|19/10/2010|priority 2 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|documentation|procedure process error|scm|scm|intercompany|houston|Material not delivered to plant|Material  not delivered to plant
ZF|100035118|02/11/2005|priority 3 |Q3|PETRONAS|unknown info region|NOCO ATCO NOTE NOPT|assembly test|function|ss compl. & w.over workover riser|unknown info object_part_desc_|assy|missing operation|Fluid flow from WOCM return|no failure found
ZF|P6000042968|04/09/2009|priority 1 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO NOPT|assembly|unknown info damage_desc|scm|scm|engineering|ecn change|P/N7104715  hydraulic coupler|PO not updated
ZB|100006609|21/11/2013|priority 3 |Q1|PETROBRAS|unknown info region|ATCO NOCO NOTE|other defect|physical|scm hydraulic|hydraulic couplers|fabrication shop equipment|lack of maintenance|RTA MEQS/2013/0037A|Falha da demanda de manutenção do SCM
Q1|7102643|06/12/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOPT NOCO ATCO|electrical|pressure transducer|defect locations offshore field|åsgard a|initial direct product problem|function|SCM 12 ÅsgA P-1H PT Func. PMV malfunct.|unknown info root_cause
Q1|100018600|06/02/2003|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Petrobras reject all SCM's|unknown info root_cause
ZF|P6000093498|27/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|design|drawing error|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|Tubing too long|Drawing corrected  S/N req. SCM tubes
Q3|7103233|09/12/1999|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTI NOCO|hydraulic|chemical control valves|defect locations onshore|fat|initial direct product problem|documentation|CIDV test results out of accept criteria|Testing method is not correct
ZF|P6000068912|15/04/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|function|scm|scm|other causes damage|cause not found|Loss of communication on stack-up test.|Cause to be stated in SO 1240922
ZF|P7000024900|14/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm|scm|vendor|operator error|Alteração de valores.|unknown info root_cause
ZF|P6000068912|08/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO ORAS|test|missed operation|scm|scm|vendor|equipment malfunction|S/N 6 was sent to Dunfermline|TP and CPUboard error followupQN created
ZF|100020562|14/02/2006|priority 2 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|assembly test|function|scm|scm|other causes|no noncompliance|FAILURE TO OPPERATE TO PRD REQUIREMENTS|CHECK VALVE OPERATES CORRECTLY
Q3|100017305|14/01/2003|priority 3 |Q3|STATOIL|unknown info region|NOCO NOTI NOPT ATCO|scm rcm|scm|defect locations onshore|workshop other|root cause assembly test|workshopassembly test error|SCM is leaking silicone oil.|unknown info root_cause
ZF|P6000100953|26/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|design|specification error|computer system software|sem tpu config|engineering|procedure error|Wrong in new config|unknown info root_cause
ZF|P6000031350|22/04/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|test|leakage (fluid)|scm|scm|other causes damage|no noncompliance|Water in silicon after hyperbaric test|No errors found in test
ZF|100049000|04/04/2006|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|design|user documentation procedures|scm|scm|engineering|engineering error|HFT DISCREPENCY|HFT Instructions Issues
ZF|100036936|06/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|wear & tear|scm el opt components|el. connector|other causes damage|cause not found|W&T - Corrosion on EC (3 EA)|unknown info root_cause
ZE|P6000091085|13/05/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|process procedure ineffective|OWIRS Deadman Sequence - Cancelled|Cancelled
Q3|7105597|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|product defects for dept.|scm|defect locations onshore|fks adm.|initial direct product problem|operation & maintenance manual (omm)|Siliconoil  draining  refilling.|unknown info root_cause
ZF|100037229|08/10/2018|priority 3 |Q3|PETROBRAS|unknown info region|NOPT ATCO NOCO NOTE|assembly|over torqued|scm|scm|assy|operator error|MMR - Broken Screw Bladder Assembly|unknown info root_cause
ZF|P7000039672|29/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|assembled incorrectly|scm sem el opt component|sem mech. components|intercompany|kongsberg|Missing O-Ring from top/bottom WedgeDisk|unknown info root_cause
ZF|P6000116166|03/09/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|machining|length depth error|scm hyd mech components|hydraulic tubing|vendor|specification not followed|Wrong lenght on tube PN P6000038406|Wrong length on tube from bending work
ZF|P6000091085|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000084906|12/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|7103233|unknown info defect_date|priority 1 |Q3|unknown info customer_name|unknown info region|NOTI NOPT ATCO NOCO|electrical|printed circuit board|defect locations onshore|inhouse fat|initial direct product problem|function|SIO card errors during low temp. test|SIO fault in the freeze test.
Q1|7103234|03/01/2003|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|scm rcm|scm|defect locations offshore field|fpso terra nova|initial direct product problem|leakage|TNO SCM 06I HP internal leak|unknown info root_cause
Q3|7103234|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTI NOCO ATCO|product defects for dept.|scm (mech) flow meter|defect locations onshore|fat|initial direct product problem|function|Min. flow test results out of limits|unknown info root_cause
ZF|P6000074156|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000069056|16/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|test omitted|scm|scm|test|missed operation|SCM not mobilized acc. to FMC procedure|Time constraint
ZF|7103233|15/06/2005|priority unknown info priority|Q3|OVERALL PROJECT ROLL-UP|unknown info region|NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|other causes|do not use|SIO failure ?|Not known.
Q3|7101463|25/06/2002|priority 3 |Q3|MOBIL EG|unknown info region|NOTI ATCO NOCO NOPT|electrical|printed circuit board|defect locations onshore|workshop other|initial direct product problem|function|DHI-failure|unknown info root_cause
ZF|P6000068770|05/02/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|documentation|procedure process error|scm|scm|qa qs qi|goods receiving inspection error|Item used without inspection|Equipment used without IMDR
ZF|P6000074156|06/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SEM failure detected in extend. test
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|NOPT ATCO NOTE NOCO|assembly test|function|scm|scm|vendor|vendor design error|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|HFT DOC. & TEST UNIT DISCREPANCY
ZF|100020562|12/05/2005|priority 1 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|assembly test|function|scm|scm|other causes|qn cancelled|SCM 18 4-20 ma readings out of spec.|"RIT failure on SEM ""A"""
ZF|7104670|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|scm|scm|vendor|equipment malfunction|08-MEGI-014: AIB Voltage Reference Error|AIB Vol Ref Error
ZF|P6000037215|04/05/2011|priority 2 |Q3|ENGIE|NORTH SEA|NOCO ATCO NOTE|damage|damage due to handling|electric products|other electric products|vendor|operator error|Actuator leakage|Bad workmanship during installation
Q3|7104075|unknown info defect_date|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|product defects for dept.|test equipment|defect locations onshore|montasje|initial direct product problem|material|Dårlig kontakt i gjennomføringer i tank.|unknown info root_cause
ZF|P6000029747|04/09/2009|priority 1 |Q3|GJØA|unknown info region|ATCO NOPT NOTE NOCO|assembly|unknown info damage_desc|scm|scm|engineering|ecn change|P/N7104715  hydraulic coupler|ECN Class 1 should be Class2
ZF|P6000055198|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
Q3|100025337|28/11/2002|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Return line bent incorrectly|unknown info root_cause
ZF|100017997|19/07/2010|priority 1 |Q3|BP|unknown info region|NOTE ATCO NOPT NOCO|coating plating|coating defect|wocs|installation workover control system (iw|vendor|coating defect|Cor-pro didn't coat can IWOCS 2 correct|Cor-pro didn't coat IWOCS 2 can correctl
ZF|P7000039672|08/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|design|dbi error|hydraulic distribution|other hydraulic components|engineering|ecn change|ECN  6147855 - PN  P7000039672|ECN
ZF|P6000076121|09/11/2011|priority 3 |Q3|CNOOC|unknown info region|ATCO NOCO NOPT NOTE|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips inside the HP-Config Plug|Plugs not cleaned by supplier.
Q3|100018600|21/01/2003|priority unknown info priority|Q3|PETROBRAS|unknown info region|NOTI ATCO NOCO NOPT|electrical|sem powersupply|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Power supply failure|Short cicuated tantalum capacitor
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|NOTE NOCO ATCO|damage|damage during assembly|connectors|electrical optical|other causes damage|qn cancelled|SCM11 connector damaged|unknown info root_cause
ZF|100048038|31/03/2007|priority 2 |Q3|AGBAMI|unknown info region|NOTE NOCO ATCO NOPT|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 25|Damage in warehouse handling
Q3|7100320|02/12/1999|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|product defects for dept.|scm|defect locations onshore|workshop other|unknown info cause_group_desc|unknown info cause_desc|Oppgrader Hercules 10-BETA til 10-OMEGA|unknown info root_cause
ZF|P7000039672|05/09/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|dbi error|object types to eng matl class|kits|engineering|ecn change|ECN  7090703    PN  P7000017838|Error-concept/calculation
ZF|100038200|02/06/2005|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly test|function|scm|scm|assy|missing operation|RS 485 failure to read on ETU SCM63|Failure during RIT test procedures
ZF|P6000088604|01/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000031350|20/04/2009|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|documentation|missing certificates records|electronic boards|dhi|vendor|unknown info cause_desc|Process problems|Travellers not delivered with boards
ZF|100035118|13/07/2005|priority 3 |Q3|PETRONAS|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during assembly|scm|scm|assy|operator error|Unable to control COVHP from SEM A|Incorrect wiring
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 24|Investigate Coupler Rotation-BPAT SCM 24
ZF|100034440|04/10/2005|priority 2 |Q3|HOUSTON STOCKING MK IV|unknown info region|NOTE ATCO NOPT NOCO|assembly test|interface of components issue|scm|scm|vendor|fabrication error|THREADS WERE DAMAGED DURING ASSEMBLY|Incorrect threads on plugs.
Q1|7101401|23/11/1999|priority unknown info priority|Q1|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Request for SCM lower skirt & latch unit|unknown info root_cause
ZE|100025661|24/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|projects|documentation error|Wiring mistake on COV HP|Engineering error.Procedures not updated
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZD|P6000084242|13/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PARTNUMBER|INCORRECT PARTNUMBER
Q2|7102643|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|product defects for dept.|scm (mech) valves|defect locations onshore|workshop other|problem causes defect causes|production|LP Ventiler harhatt HP på pilotsteget.|unknown info root_cause
ZF|7102643|28/01/2004|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE|vendor|unknown info damage_desc|scm electrical|rov el. connectors|vendor|material error|AS FD 86  Lock-ring for Tronic connector|unknown info root_cause
ZE|7102969|25/04/2005|priority 3 |Q3|MOBIL EG|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|(change to ZF)|unknown info root_cause
ZF|100036936|22/04/2005|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Not performed HFT do to lack of time|unknown info root_cause
ZF|P6000088751|09/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000104116|18/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|machining|surface finish error|scm hyd mech components|other mechanical components|vendor|specification not followed|Damage on Sem Housing|Machining error not acc. surface finish
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 18|Investigate Coupler Rotation-BPAT SCM 18
ZB|100048038|05/12/2006|priority 1 |Q1|CHEVRON|WEST AFRICA|NOTE ATCO NOPT NOCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|hydraulic valves|vendor|component error|RPXT SCM #4 leaking fluid|RPXT SCM #4 leaking fluid
ZB|P6000058949|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|functional|scm|scm|projects|material error|Gullfaks Claim 220 SCM (615)|CPU boards failed
ZE|100020562|10/05/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|sensors|scm pressure transmitter (pt)|causes for improvement|process procedure not being followed|Escape: Controls Data Books|See Orange Event - 200129497
ZF|P6000098616|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100035014|19/10/2010|priority 2 |Q3|STATOIL|unknown info region|NOCO NOTE|documentation|incorrect user documentation (customer)|scm|scm|materials stores|operator error|Material not delivered to plant|unknown info root_cause
ZD|100037428|23/05/2009|priority 2 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|missing certificates records|ss compl. & w.over xt general|tree assembly|vendor|operator error|CERT ISSUE|NVL - Missing Certification
ZF|P6000093498|01/08/2016|priority 2 |Q3|RLWI STACK 4|unknown info region|ATCO NOCO NOTE|assembly|assembled incorrectly|wocs|installation workover control system (iw|other causes damage|damage from wear and tear|RLWI SN 01  Baseplate contamination|corrosion particles punchured bladder
ZE|P6000068924|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update SRM PSM - Luanda Workshop|Operator write N/A  doc. not updated
ZF|100049000|09/09/2009|priority 2 |Q3|BP|GOM|ORAS NOTE NOCO|test|cleanliness|scm|scm|test|operator error|BP Atlantis (DHFC) SCM 05|Wrong fluid type
Q3|7100320|20/11/2001|priority 3 |Q3|PETROBRAS|unknown info region|NOTI NOCO NOPT ATCO|scm rcm|scm|defect locations offshore field|campos basin|initial direct product problem|leakage|SCM Hercules LP Leak/SEM A AI150 malfunc|HP control valves  excessive leakage
ZF|P6000073687|30/03/2012|priority 3 |Q3|FRADE BVFRADE PH II|unknown info region|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|vendor|wrong part delivered|wrong insulation sheet ++|Error in BOM at Kitron
ZE|100025661|09/05/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|topside products|subsea control unit (scu)|causes for improvement|process procedure ineffective|PSM20018386 Update|Procedure Improvement - PSM update
ZF|P7000016420|22/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|electric products|electrical connector|assy|operator error|conector de base danififcado|unknown info root_cause
ZB|100066325|04/10/2016|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|specification error|scm|scm|assembly|other specify in comments|Statfjord GC 187795 Connector PT sensors|Rejected no fault found
ZF|P6000093498|27/10/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|assy|operator error|PSD600-1 -CAN BUS Communication Fails|Opr mistake  Incorrect wire clamping
ZF|100025661|21/03/2006|priority 3 |Q3|SHELL|GOM|NOCO NOPT NOTE ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor audit|unknown info cause_desc|LEAK ON INTERNAL  ACCUMULATOR N2 LINE|Int. Accumulator N2 Line leak  handling?
ZF|7103234|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|other defect|functional|scm|scm|other causes damage|qn cancelled|No feedback from sensors|See SN 300162480
ZF|P6000105542|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100025661|05/10/2005|priority 3 |Q3|SHELL|GOM|ATCO NOPT NOTE NOCO|assembly test|function|scm|scm|vendor|vendor design error|FAILURE TO MEET TEST ACCEPTANCE CRITERIA|HFT DOC. & TEST UNIT DISCREPANCY
ZE|P6000042308|13/04/2010|priority 4 |Q3|TULLOW|WEST AFRICA|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|topside products|n a sw|causes for improvement|process procedure not being followed|Escapes: Procedure update W/O ECN|unknown info root_cause
ZF|P6000042969|13/05/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|electronic boards|dhi|vendor|unknown info cause_desc|Cards fails to read gauges|Error to be confirmed in QN200128479
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOPT NOCO NOTE|design|dbi error|scm hyd mech components|other mechanical components|engineering|specification error|Wrong Bill Of Material and wrong parts|Coupler Interface on m.block (spc error)
Q3|7104020|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI ATCO NOPT NOCO|product defects for dept.|scm (el) electric rack|defect locations onshore|inhouse fat|initial direct product problem|documentation|Error in wiring diagram DWG-211635|unknown info root_cause
ZF|100037428|15/03/2005|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOPT ATCO NOTE|design|drawing error|scm|scm|engineering|engineering error|Wrong readings detected during EFAT|unknown info root_cause
ZF|P6000104112|09/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm sem el opt component|other scm sem el opt components|vendor|clarification|Power level verificaition fiber failed|Follow-up through QN 200380489
ZF|P6000105708|21/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|procedure process error|topside products|other topside products|test|missed operation|Sourcing not set up correctly|Sourcing not set up correctly
ZF|P6000103208|17/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|leakage (fluid)|scm|scm|other causes damage|no noncompliance|Possible gas leakage in SCM|Pressure increase due to temperature
ZD|7103233|05/10/2010|priority 1 |Q2|SUNCOR|unknown info region|ATCO NOTE NOPT PAGE NOCO|design|specification error|scm|scm|intercompany|kongsberg|Adaptor Plate & Manifold Bolting Change|Vendor Liability
ZF|P7000000897|09/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm hyd mech components|control valve|other causes damage|damage from wear and tear|Flow meter - HP Supply|Equipamento retornou do campo
ZF|100037965|16/12/2005|priority 3 |Q3|BP|unknown info region|ATCO NOCO NOPT NOTE|assembly test|cleanliness|scm|scm|assy|missing operation|SCM hydaulic cleanliness out of spec.|SCM contaminated by external equipment
ZF|P7000001621|12/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm|scm|other causes damage|damage from wear and tear|Teste de Pressão Manifold Block 03 - LP|Test Stand não suporta pressão indicada
ZF|P7000020444|19/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|test omitted|scm|scm|test|tooling|Etapas do procedimento não realizada|Etherscope não funcional
ZF|P7000039672|14/12/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|dimension (tolerance)|object types to eng matl class|scm|assembly|damaged during assembly|Tube Vacuum small and Test High Pressure|unknown info root_cause
ZF|P7000039672|03/02/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|other defect|part lost|scm el opt components|el. connector|qa qs qi|goods receiving inspection error|Falta de o-rings|unknown info root_cause
ZF|P6000116360|14/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|interface issue|scm|scm|engineering|continuous improvement|SCM clashes with MRT|DWG-0223681-001 needed to be updated
ZF|P6000068912|23/06/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|component error|test and transportation|sensor simulator (sesi)|engineering|dbi error|PT/TT Sensors Calibration and startup|DBI error
ZF|P7000016420|07/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|other defect|physical|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|vendor|specification not followed|MARCAÇÃO DA RASTREABILIDADE|CAUSA VENDOR
ZF|P7000039672|16/10/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|electronic boards|main boards cpu & i o|intercompany|kongsberg|SRT - Pre-Salt #12 - Relay 2|PO 47636681 - 117094 FMC KONGSBERG SUBSE
ZF|P7000039672|11/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|marking|marking content error|scm|scm|paintshop|operator error|Marcação SCM com erros de Escrita.|unknown info root_cause
ZF|P6000101955|17/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000063632|23/12/2010|priority 1 |Q3|AQUILA PHASE 2|unknown info region|ATCO NOCO NOTE NOPT|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|100034440|30/11/2010|priority 2 |Q3|POGO|GOM|ATCO NOPT NOCO NOTE|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P6000057855|07/12/2010|priority 2 |Q3|ENI|unknown info region|NOTE ATCO NOCO NOPT|test|function|electronic boards|eth.net items|test|incorrect set up testing|TIF ping test fails - packet loss > 1%|Lack of test-equipment maintenance
ZB|P6000042968|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 08|Software improvement/correction
ZB|100035400|04/01/2010|priority 2 |Q1|HESS|GOM|NOCO ATCO NOTE|test|function|scm electrical|processor pcbs|vendor|equipment malfunction|RAM Warning on SEM A|RAM Warning on SEM A
ZF|P6000064911|02/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|design|procedure error|scm|scm|engineering|procedure error|Test procedure  and Config|Improved & corrected TST60057930
ZF|7103233|02/06/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|drawing error|scm|scm|engineering|dwg error|GA drawing with wrong EC placement|DWG contained error  old dwg
ZF|P6000122574|03/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|scm hyd mech components|accumulator|vendor|specification not followed|Too big dim (D5 on drawing)|sealing surface diameter out of toleranc
ZB|100055600|24/03/2009|priority 2 |Q1|TALOS|GOM|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hydraulic|hydraulic control valves|vendor|equipment malfunction|SCM 96 DCV #8 Leaking|SCM 96 DCV #8 Leaking
ZF|P6000058949|21/02/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|design|material master error|scm|scm|engineering|ecn change|Serrated washers on bolts|ECN change  part assy after old rev
ZE|100051991|11/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|customer requested|WEL Customer Request Improvement|unknown info root_cause
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|NOPT NOTE NOCO|other defect|unknown info damage_desc|fks quality system issues|quality management system|other causes damage|unknown info cause_desc|Rosa 307 communication problems|unknown info root_cause
Q1|100005667|20/07/2000|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|hydraulic|hydraulic control valves|defect locations offshore field|åsgard a|initial direct product problem|leakage|SCM HP change over valve leak  well X2-H|No fault found at FMCKS
ZF|100049392|01/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|drawing error|scm|scm|engineering|engineering error|DWG for SCM not released in SAP|DWG not released in SAP
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|NOTE ATCO NOCO|damage|damage during assembly|connectors|electrical optical|other causes damage|qn cancelled|SCM11 connector damaged|Duplicate
ZB|P6000079433|28/03/2014|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|functional|scm|scm|other external causes|customer error responsibility|Victor Bravo claim #12 SCM|Fault is CPI DHI card. Rejected warranty
ZF|P7000024191|01/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm hyd mech components|other hydraulic components|intercompany|kongsberg|FILTRO SEM ORING|Filtro sem o-ring
Q3|7104033|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM # 05 El.rack A an B|unknown info root_cause
Q3|7101401|17/10/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|customer goods receipt|initial direct product problem|function|Crosstalk comms. interference (offshore)|Marlim Manifold crosstalk
Q1|7103233|08/01/2003|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|electrical|modems communications|defect locations offshore field|fpso terra nova|initial direct product problem|function|SCM TN0 HPE4 01P comm. failures|unknown info root_cause
ZE|P6000109984|17/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm el opt components|el. opt. connector|causes for improvement|process procedure not being followed|oc not fit in outer can|GWI102  7.3.1 not followed on OC rev B
ZF|P7000039672|15/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|component error|scm|scm|assy|lack of training|SCM colapsado durante teste Hiperbárico|unknown info root_cause
ZF|100035118|26/10/2007|priority 2 |Q3|CHINGUETTI PHASE II|unknown info region|NOPT NOCO NOTE|assembly test|function|scm|scm|manufacturing|programme error|(SS) UNABLE TO POWER UP DOWN HOLE GAUGE|programme error
ZF|P6000104112|21/10/2018|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|test omitted|object types to eng matl class|scm|test|tooling|Concession to deviate from procedure|unknown info root_cause
ZF|P6000121268|13/07/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|damage|damage during testing|scm|scm|test|damaged during testing|In SCM RIT stage O-ring found damage|O-Ring damage
Q3|7104075|26/04/2000|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI ATCO|electrical|printed circuit board|ext. loc. kos houston|work shop|initial direct product problem|function|Over voltage alarm and no PT reading|SIO card was not reset
ZF|100037427|20/06/2005|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|assembly test|cleanliness|scm|scm|vendor audit|unknown info cause_desc|Received SCM with defects|unknown info root_cause
ZF|100048038|04/10/2006|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|do not use|scm|scm|vendor|component error|AI 151 card has to be updated|Bad workmanship
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM MAN/SIV 05|Software improvement/correction
ZF|P7000039672|20/05/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|component error|electronic boards|main boards cpu & i o|intercompany|kongsberg|Bistable Relay#1 SEM 65A & SEM 65B|unknown info root_cause
ZF|P6000138867|04/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|damaged during testing|scm|scm|test|operator error|SCM exposed with 1100 Bar on HP 1|SCM HP supply exposed to 1100bar
ZF|P7000001843|30/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|component error|scm|scm|other causes damage|cause not found|Falha no Flowmeter durante In House Test|unknown info root_cause
ZF|P7000039672|19/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm hyd mech components|outer can|vendor|final inspection error|Outercan não monta|101545 - KRISTIANSANDS SKRUEFABRIKK &
ZE|100069556|04/05/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|process procedure ineffective|SCM 09P Bladder RCA|unknown info root_cause
ZF|P6000076121|19/09/2011|priority 3 |Q3|CNOOC|unknown info region|NOCO NOTE NOPT|marking|marking content error|scm|scm|assy|operator error|Wrong wiring on SCM|Wrong marking by Opr caused wiring error
ZB|3787102|31/10/2006|priority 4 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|change deviation request|part substitution request|scm|scm|materials stores|improper packaging & storage|Cont. Mod. delivered without KX + Hyd Co|Lack of information on procedures
ZF|7101463|03/03/2005|priority 3 |Q3|MOBIL EG|unknown info region|NOPT NOCO ATCO NOTE|design|user documentation procedures|scm|scm|vendor|do not use|part number discrepency on ARF|Documentation of p/n
ZF|P7000001843|19/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|component error|scm|scm|intercompany|kongsberg|Falta de comunicação SEM B|unknown info root_cause
ZF|P6000062454|06/04/2011|priority 2 |Q3|DAEWOO|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (fluid)|scm|scm|test|incorrect set up testing|(SS) SCM LP DCVs Leaking|Testing issues
ZF|P6000073687|13/06/2012|priority 3 |Q3|FRADE B.V.FRADE PH II|unknown info region|NOCO ATCO NOPT NOTE|damage|damage during testing|scm hyd mech components|hydraulic coupler|assy|damaged during assembly|HC 2 and HC6 coupler damaged|Damaged female couplers due to SCM TS
ZF|100005667|13/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|P6000104116|24/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|Cannot assemble lifting handle|Part not according to specification
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of resources|CAR 6 RCA Actions_2 from RPT10033107|unknown info root_cause
ZF|100018600|01/10/2003|priority 2 |Q3|PETROBRAS|unknown info region|NOPT NOTE NOCO ATCO|assembly test|documentation general|scm hydraulic|other scm hydraulic|engineering|design specification drawing error|SCM not according to dwg|Error in drawings and BOM
Q3|7104670|18/10/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|scm rcm|scm|defect locations offshore field|heidrun tlp|initial direct product problem|function|Comms errors  FSM tied into SCM  (D-1H)|unknown info root_cause
ZF|P6000108984|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|interface issue|scm hyd mech components|outer can|other causes damage|no noncompliance|To short threads in outercan|Interface with EC adapter verified OK
ZB|100049000|22/05/2009|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|damage|unknown info damage_desc|scm|scm|vendor|material error|DHFC SCM 06 RAM Warning|Defective RAM chip
ZB|100066325|07/10/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm|scm|test|incorrect set up testing|Statfjord Claim Defect in SCM 610|MRM600 factory default conf.not changed
ZF|P6000055605|28/03/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT OSNO OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM not communicating with MPFM|unknown info root_cause
ZF|P7000020444|24/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|DCV Não Conforme|unknown info root_cause
ZB|100050519|26/02/2015|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|functional|scm|scm|other external causes|customer error responsibility|SCM# failure after reworks|outside warranty period
Q3|100005667|17/10/2000|priority 4 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTI NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM upgrades after removal of outer can|unknown info root_cause
ZF|100025661|12/07/2006|priority 3 |Q3|SHELL|GOM|NOPT NOCO NOTE ATCO|assembly test|function|scm|scm|vendor|component error|DHI NOT CONNECTING|DHI NOT CONNECTING
ZF|P7000024191|22/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|other defect|physical|scm hyd mech components|control valve|vendor|missing parts|DCV não conforme.|Oceaneering Rotator - PO 47573794
ZF|P6000100953|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
Q3|100005667|13/04/2000|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|etu software|wocs software|defect locations offshore field|transocean searcher|initial direct product problem|function|Åsg SCM 59  no sensor comms with SEMA|No fault found in KOS workshop
ZD|P6000149536|12/12/2017|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|marking|marking content error|object types to eng matl class|scm_assy|marking|operator|Marking issue|unknown info root_cause
Q3|7102969|20/12/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOTI NOCO ATCO NOPT|hydraulic|hydraulic control valves|defect locations onshore|customer goods receipt|initial direct product problem|leakage|Refurbishment/overhaul of valves|unknown info root_cause
ZF|100017278|10/06/2005|priority 4 |Q3|STATOIL|NORTH SEA|NOCO NOTE|assembly test|function|scm|scm|other causes|do not use|PT20 sensor show 200 bar > actual press.|Wrong offset value in conf. parametres
ZF|P6000055198|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|29/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Marcação do transformador incorreta|unknown info root_cause
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|machining|angle error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100037130|22/11/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leak|scm|scm|qa qs qi|operator error|Water ingress in SCM (hyperbaric tank)|Testprocedure not followed.
ZF|P7000039672|20/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|component error|scm hyd mech components|check valve|vendor|final inspection error|Check Valve out of Acceptable Criteria|1242 - HTS maskinteknikk as
Q3|7106268|19/10/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|scm rcm|scm|ext. loc. luanda (angola)|work shop|initial direct product problem|documentation|HXT - X2 pressurised to 520 bar|unknown info root_cause
ZD|P6000080678|15/01/2016|priority 4 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|procurement|part not protected as per dbi|scm|scm|intercompany|kongsberg|Persephone  SCM  Missing item|unknown info root_cause
ZF|100026567|24/10/2003|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTE|assembly test|function|scm electrical|hydraulic flow meters|assembly test|assembly test error|Failure on SCM#2 (see ref. notification)|Broken wire connection.
ZF|P6000102687|05/11/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|change deviation request|process substitution request|object types to eng matl class|scm|projects|customer error|Concession to deviate from procedure|unknown info root_cause
ZF|100046112|10/02/2006|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOPT ATCO NOCO|assembly test|assembled incorrectly|scm|scm|assy|operator error|HP PT's WERE CROSS CONNECTED|human error in wiring
ZF|P7000024900|02/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm|scm|test|operator error|SRT BC10-34 (Leitura tensão)|unknown info root_cause
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|ATCO NOPT NOCO NOTE|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 23|Investigate Coupler Rotation-BPAT SCM 23
ZF|P6000122626|22/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|assembled incorrectly|scm|scm|engineering|procedure error|EC 3&4 wiring swapped|In-house test procedure updated
ZF|100020278|10/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|procedure error|scm|scm|engineering|engineering error|DBI for Chemplex 750 to be alternative|DBI for Chemplex 750 to be alternative
ZE|P6000028371|22/12/2010|priority 2 |Q3|SHELL|GOM|NOTE ATCO NOCO|damage|damage during assembly|scm hyd mech components|outer can|variance|enhance process|No reading from WLD|Two technicians required  outercan assy.
ZF|P7000024191|30/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|function|instrumentation|scm pressure transmitter|engineering|continuous improvement|PT 1A com desvio de leitura|unknown info root_cause
ZF|P6000068924|01/03/2012|priority 1 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO|design|drawing error|scm hyd mech components|outer can|other causes damage|qn cancelled|Outercan missing holes.|Outercan produced acc to DWG
ZF|P1000018406|02/03/2010|priority 3 |Q3|BP|GOM|NOTE ATCO NOPT NOCO|marking|no marking|scm|scm|engineering|dwg error|No p/n marking ID in drawing|No p/n marking ID in drawing
ZF|100035013|27/02/2006|priority 3 |Q3|SHELL|unknown info region|ATCO NOPT NOTE NOCO|assembly test|do not use|scm|sem|vendor|component error|Failing communication with CAM200|Defective components  U202 & L203
ZF|P6000064911|01/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|engineering|engineering error|Too short screws|Variance of trafo-foot thickness
Q2|7102643|unknown info defect_date|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|electrical|rcm electronics|defect locations onshore|montasje|initial direct product problem|material|Refurbishment  Bytting av Trykktandusere|unknown info root_cause
ZB|100020278|13/04/2011|priority 3 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO ATCO|damage|damage due to handling|scm hyd mech components|control valve|intercompany|houston|Warranty claim Megi Sea # 32|Error in handling
Q2|7101172|unknown info defect_date|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|hydraulic|hydraulic control valves|defect locations onshore|montasje|initial direct product problem|material|GFS SCM 07  Bytting av solenoider|unknown info root_cause
Q3|7102643|19/10/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOTI ATCO NOPT NOCO|scm rcm|scm|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|Silicone oil leak from SCM compensator|Badder hose clamp was not tight
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO DLFL|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000039672|01/12/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|misalignment interface error|scm hyd mech components|outer can|vendor|specification not followed|Top Plate não Monta na Outer Can|unknown info root_cause
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #5 Wiring|BPTH SKOFLO SCM SN #5 Wiring
ZF|100037966|20/01/2009|priority 1 |Q3|BP|unknown info region|NOCO NOTE|test|function|scm|sem|test|missed operation|B18 SCM  - SEM A communication problems|unknown info root_cause
ZF|100006609|15/04/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm hyd mech components|outer can|engineering|engineering error|Problemas com as dimensões da hose house|Erro no projeto.
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTE|electrical|pressure transducer|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 31 ÅsgB Y-4H PT func. AWV malfunct.|unknown info root_cause
Q3|7104033|20/01/2000|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTI|mechanical|outer can|defect locations onshore|workshop|initial direct product problem|marking|12 pin el. connectors to be marked|Possible to connect wrongly with ROV
ZF|7103234|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|test|function|scm|scm|other external causes|unknown info cause_desc|Communication missing|SELF CORRECTED
Q3|7106268|21/02/2000|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI NOPT ATCO|scm rcm|scm|defect locations onshore|fks adm.|initial direct product problem|documentation|DIV.|unknown info root_cause
ZF|P6000028371|14/04/2008|priority 3 |Q3|SHELL|unknown info region|NOCO NOPT ATCO NOTE|damage|damage during assembly|connectors|electrical optical|assy|operator error|EC wire isolation damaged|damaged during wire pull through tube
ZF|P6000068924|29/05/2012|priority 3 |Q3|TOTAL|unknown info region|NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|EC9 mounted wrong way|Human error while mounting EC to TS
ZF|100048038|04/09/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|marking|marking content error|scm|scm|vendor|specification not followed|wrong text marking on top plate|incorrect position of text and text
ZF|P6000064909|21/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|other defect|functional|scm el opt components|el. connector|engineering|specification error|slange sklir av på EC`ne|Tie wrap not tight enough on hose to EC
ZB|7102969|30/07/2007|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly test|interface of components issue|scm electrical|rov el. connectors|other causes|do not use|Electrical Flying lead stuck on SCM Elec|Closed for trending/analysis.
ZD|100015314|12/08/2004|priority 2 |Q2|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|unknown info region|NOCO ATCO NOPT NOTE|marking|marking location error|scm|scm|vendor|specification not followed|INCORRECT LABELLING OF TRONIC CONNECTORS|unknown info root_cause
Q1|7104670|02/10/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|scm rcm|scm|defect locations offshore field|transocean prospect|initial direct product problem|function|SCM 05 Heid. SEM B frameerror(not inst.)|unknown info root_cause
ZF|100034629|13/09/2005|priority 3 |Q3|STATOIL|unknown info region|NOCO ATCO NOPT NOTE|assembly test|assembled incorrectly|scm|scm|assy|missing operation|PRESSURIZING RETUR LINE ON SMC|Difference beetween dwgs and real umb.
ZF|P6000088604|22/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. testNo SCM failure detected in extend. test
ZF|P6000098616|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000068924|25/10/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|assy|operator error|Wiring fault on Trafo 4|Wires switched during assembly
ZF|7104075|06/06/2006|priority 3 |Q3|SHELL|GOM|NOTE ATCO NOCO NOPT|assembly test|function|scm|scm|vendor|component error|INTERNAL PT FAIL IR TEST|INTERNAL PT FAIL IR TEST
ZE|7101937|12/11/2004|priority unknown info priority|Q3|LUFENG|unknown info region|NOCO NOTE NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|other subsea control|miscellaneous subsea control|administration cause|documentation error|Pre-charge kit for SCM not mobilized|unknown info root_cause
ZF|P7000016420|01/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|tooling|Dano em área de vedação de Adapter Plate|Problema na área de vedação
Q3|3812476|08/11/1999|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTI NOPT|hydraulic|hydraulic control valves|defect locations offshore field|transocean prospect|root cause other|customercustomer error|SCM HP hyd leak when testing offshore|Leaking CVs/CVs were contaminated/dirty
ZF|P6000031350|15/05/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Filling and drain-ports switched places|unknown info root_cause
ZF|P7000000897|07/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|other defect|physical|scm|scm|assy|damaged during assembly|Center tube damaged SCM SN:05|Center Tube damaged
ZF|P7000000897|02/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|vendor|operator error|Incorrect instrumentation|Inamon - erro na instrumentação
ZF|100035014|22/08/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|engineering|unknown info cause_desc|IO-card problems Canbus disabled automat|unknown info root_cause
ZF|P7000016420|26/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|coating plating|incorrect colour coating|scm|scm|other causes damage|cause not found|Revestimento do mecanismo de travamento|unknown info root_cause
ZF|P7000002082|02/10/2018|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|object types to eng matl class|scm|assy|operator error|MMR - Damged Screw from Outer Can|Human error
ZF|P6000080678|12/08/2014|priority 4 |Q3|PLUTO EXPANSION|unknown info region|NOCO ATCO NOTE NOPT|test|wrong test procedure used|scm|scm|test|operator error|Xena - SCM HFT Procedure|Wrong PRD used and missing test equipmen
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCVs and strainer|DCV/COV with Cobalt pilot ball
ZB|100068622|23/04/2015|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Issues during SCM testing during DEMOB|unknown info root_cause
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOTE NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of resources|CAR 8 RCA Actions_2 from RPT10033107|unknown info root_cause
ZF|P7000024191|11/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|missed operation|scm|scm|test|incorrect set up testing|Testado em desacordo com o Procedimento|unknown info root_cause
ZF|P6000076121|10/10/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wiring fault PT 2 and PT 13|Wiring fault. Human error
ZF|100037426|01/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE|design|procedure error|scm|scm|engineering|procedure error|Error in FAT procedure and GA DWG|Procedure Error
ZF|P6000083428|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100056918|21/06/2011|priority 3 |Q1|PLUTOPLUTO PRODUCTION 05|unknown info region|NOTI DLFL NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Warranty Claim WELFAFMC110|unknown info root_cause
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|assembly test|cleanliness|scm|scm|other causes damage|unknown info cause_desc|SCM was full of calcium and rust|Cleaning and preservation not performed
ZF|P6000028371|10/07/2008|priority 4 |Q3|SHELL|GOM|NOTE NOCO ATCO NOPT|documentation|unknown info damage_desc|fks quality system issues|noncompliance to industrial standard|other external causes|unknown info cause_desc|Manufacturing documentation to be cont..|unknown info root_cause
ZB|100052701|01/06/2010|priority 2 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOTE|other defect|functional|scm|scm|other external causes|customer error responsibility|WARRANTY CLAIM TYR SCM Well B1|No failure found SCM is healthy
ZF|7105597|06/10/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|Wrong value on calibration test.|standardization of return pressure test
ZF|P6000058949|26/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|Engineering error
ZF|P6000068924|31/08/2011|priority 3 |Q3|TOTAL|unknown info region|NOPT NOTE NOCO ATCO|damage|damage during testing|scm|scm|test|incorrect set up testing|350V på SEM|Incorrect voltage to transformers
ZF|100018600|19/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|DLFL NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MMR - Outer Can Welding|unknown info root_cause
ZD|P6000083428|08/05/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|incorrect certificates records|test and transportation|other scm test & transport equipment|intercompany|kongsberg|CERT ISSUE|unknown info root_cause
ZF|P6000050867|21/10/2010|priority 1 |Q3|PETROBRAS|GOM|NOTE NOCO ATCO NOPT|documentation|procedure process error|electric products|electrical components|engineering|procedure error|Issues with redbook|Work done before Service Order Created
ZF|P7000000897|30/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|computer system software|etu sw|engineering|engineering error|IN HOUSE / ASSINATURA DE VÁLVULAS|unknown info root_cause
Q3|7102643|17/10/2000|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTI|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM upgrades after removal of outer can|unknown info root_cause
ZB|100025661|04/09/2009|priority 2 |Q1|SHELL|GOM|NOTE NOCO ATCO|other defect|physical|scm mech w mb|other scm mechanical|other causes damage|unknown info cause_desc|Leaking Silicon Relief Valve on SCM 54|Leaking Silicon Relief Valve on SCM 54
ZF|100025661|24/09/2003|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly test|miscellaneous|scm hydraulic|hydraulic couplers|engineering|miscellaneous product design errors|Incorrect couplers specifyed  SCM 15 k|Incorrect couper specifyed
Q3|7104670|17/08/2001|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTI ATCO|scm rcm|scm|defect locations onshore|workshop|root cause assembly test|workshopassembly test error|SIO-kort brent ?|unknown info root_cause
Q1|3801623|05/09/2000|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO|mechanical|outer can|defect locations onshore|workshop|initial direct product problem|function|SCM anodes are in wrong position|unknown info root_cause
ZB|100041493|22/11/2006|priority 1 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|damage|damage from corrosion|scm|scm|other causes damage|unknown info cause_desc|Damaged exhaust line on SCM # 16 Norne|Wear and tear
ZE|P6000063531|17/01/2019|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM  SEM's damaged by P6000067816 at EC4|unknown info root_cause
ZF|100051269|24/05/2007|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|assembly test|function|sensors|leak detector|other causes|qn cancelled|ALD sensor not working on SEM A.|Error in SEM A  ref. SN 300123729
ZF|100020562|19/10/2004|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly test|leakage (hydraulic air nitrogen etc.)|scm hydraulic|other scm hydraulic|engineering|engineering error|Transaqua found in SCM silicone oil|Marginal adapter and test plate design.
ZF|P7000008275|08/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|missed operation|scm|sem|other causes damage|qn cancelled|Falha de comunicação|Cancelada por duplicidade
ZF|100048038|27/03/2007|priority 1 |Q3|AGBAMI|unknown info region|ATCO NOCO NOPT NOTE|assembly test|missed operationassy test|scm|scm|materials stores|operator error|Trafo problems on Agbami S/N 23|Damage in warehouse handling
Q1|7102643|25/01/2002|priority 3 |Q1|STATOIL|NORTH SEA|NOTI NOCO ATCO NOPT|hydraulic|hydraulic coupler|defect locations offshore field|viking poseidon|initial direct product problem|damages|SCM installation problems on well M3-H|Damaged male coupler
ZE|100054943|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|change seq. of procedure|Enfield - SCM Issue|SCM Issue
ZF|100020562|20/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|drawing error|scm|scm|engineering|dwg error|GA drawing update|DWG GA not according to as build
ZF|P6000079984|03/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|damage|damage during testing|scm test stand|other mechanical components|test|damaged during testing|Marks on baseplate mounted ECs|Wrong angle on connector wing on SCMTS
ZB|100052701|08/03/2010|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|other defect|functional|customer compliant|noncompliance to customer requirement|assy|missing parts|Tyrihans Claim 5  7 & 52 HCLD|Missing earth strap on HCLD
ZF|P6000088626|12/06/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|missed operation|object types to eng matl class|scm|projects|documentation error|Concession Request - HFT/mob scope|unknown info root_cause
ZF|P6000064911|17/12/2015|priority 1 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE|test|function|scm sem el opt component|optical penetrator (insert)|vendor|equipment malfunction|Laggan Tormore Silicone in SEM|Leakage through optical penetrator
ZD|P6000102554|17/02/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|assembled incorrectly|scm|scm|intercompany|kongsberg|SCM/Anadarko/Heidelberg/Error|SCM/Anadarko/Heidelberg/Error
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|ATCO NOPT NOCO NOTE|documentation|missing certificates records|scm|scm|vendor|specification not followed|Missing MDB Docs for BPTH SCM23|Missing MDB Docs for BPTH SCM23
ZF|100056261|19/11/2007|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly test|interface of components issue|scm|scm|engineering|engineering error|incorrect thread bush for HC72|insufficient interface check
Q1|3812476|08/04/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOTE NOCO NOPT|hydraulic|hydraulic coupler|defect locations offshore field|norne fpso|initial direct product problem|leakage|SCM 2 NORNE D-2H blocked return|unknown info root_cause
ZE|P6000108542|08/11/2017|priority 2 |Q3|TULLOW|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|electrical|specification not followed|SEM failure  MPFM|Damaged by external wiring/connection.
ZF|P6000116166|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|P6000123495|16/10/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|missed operation|scm|scm|other causes damage|no noncompliance|QA phase B check not performed|Phase B inspection was performed
ZF|P6000069056|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|7102969|19/01/2007|priority 3 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE ATCO NOPT|assembly test|function|scm electrical|other scm electrical|engineering|lack of training|Bad Pig Valve position indicator sensor.|unknown info root_cause
ZF|7103233|11/05/2007|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|functional|ss compl. & w.over xt general|pressure & temperature transducers|other causes damage|qn cancelled|Sensor has drifted|this will be logged as a SN
ZF|P6000028371|06/12/2007|priority 3 |Q3|SHELL|GOM|NOCO NOPT ATCO NOTE|assembly test|assembled incorrectly|scm|scm|assy|operator error|Cross wired PT 53 and PT 54|wiring error
ZF|P7000020444|02/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|test omitted|electronic boards|eth.net items|test|tooling|Skiped step procedure|CWDM missing
ZF|P6000029772|23/09/2008|priority 2 |Q3|ENGIE|NORTH SEA|NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|engineering|unknown info cause_desc|Batch number missing|change to batch management on screws
ZF|7101401|26/10/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|welding|material issued damaged|scm hyd mech components|outer can|fabrication shop personnel|improper handling|MMR - Outer Can Vacuum Tubing damaged|unknown info root_cause
ZF|100037130|19/07/2005|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly test|do not use|scm|scm|engineering|dwg error|Upgrade of proc. for mob of  SCM onshore|Final doc did not specify topping of SCM
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|NOCO ATCO NOPT NOTE|assembly test|missed operationassy test|scm|scm|assy|missing operation|NO TEST REQUIREMENT  FOR CRITAL FUNCTION|HFT Missing Testing Requirements
ZF|100020562|02/06/2006|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly test|function|scm|scm|vendor|component error|Faulty OTF board|Faulty OTF board
ZF|P7000039672|23/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|component error|scm sem el opt component|sem cable & wiring|intercompany|kongsberg|Falha na comunicação com a DHI|unknown info root_cause
ZD|100035014|26/09/2007|priority 2 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|incorrect user documentation (customer)|fks quality system issues|quality management system|other causes|qn cancelled|Loss of Comm with the subsea SEMs|Same case as QN200084493
ZB|7101172|17/11/2005|priority 3 |Q1|STATOIL|NORTH SEA|NOCO ATCO NOTE NOPT|raw material|defects in material|scm|scm|materials stores|operator error|Not able to open BSV after vent test|Wrong type of O-ring for that environm.
ZF|100035118|18/05/2005|priority 3 |Q3|PETRONAS|unknown info region|NOPT NOTE NOCO ATCO|assembly test|function|electronic boards|other eletronic boards|vendor|component error| ERROR WITH DHI when grounded|Error in the DHI card.
ZF|P6000122626|03/12/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wrong position on several DCV's|Incorrect assembly by operator
ZF|100029149|10/12/2003|priority unknown info priority|Q3|TOTAL|WEST AFRICA|NOTE NOCO ATCO NOPT|assembly test|workmanship general|scm hydraulic|other scm hydraulic|operation maintenance|operation error|RAGS BETWEEN SCM AND TEST STAND|unknown info root_cause
ZF|P7000039672|04/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm hyd mech components|other hydraulic components|vendor|specification not followed|Interferência no plug do filtro SCM 43|unknown info root_cause
ZF|P6000084242|03/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage during testing|scm hyd mech components|control valve|test|operator error|207 bar on return line|Hydraulic return blocked on SCMTS
ZD|7103234|29/04/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|other defect|functional|scm|scm|service :|improper job preparation|SCM Shipped Pre-Charged (Terra Nova)|unknown info root_cause
ZB|P6000108542|13/04/2016|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|material error|Tullow Jubilee FFD SCM 09 hydr leakage|Leakage hydraulic valves
ZB|P7000001621|21/11/2013|priority 1 |Q1|PETROBRAS|unknown info region|NOPT NOTI OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|RTA MEQS/2013/0055A|unknown info root_cause
ZF|7102643|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|P6000120925|27/07/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|component error|scm|scm|test|operator error|Short circuit on EC1|See follow-up closing  cause not found
ZF|100018082|11/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|ATCO NOCO NOTE|damage|damage during assembly|connectors|electrical optical|other causes damage|qn cancelled|SCM11 connector damaged|unknown info root_cause
Q1|7102643|08/08/2000|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO ATCO|scm rcm|scm|defect locations offshore field|viking poseidon|initial direct product problem|leakage|Minor leaks from SCM before installation|Damage caused by handling
ZF|P7000001621|01/03/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm hyd mech components|other mechanical components|test|incorrect set up testing|AUSÊNCIA DE PINO|unknown info root_cause
ZF|P7000001843|04/09/2017|priority 3 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|assembly|assembled incorrectly|object types to eng matl class|scm|assy|operator error|MMR - SCM does not reach vacuum|unknown info root_cause
ZF|P7000024191|23/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|scm|scm|test|incorrect set up testing|SRT SCM GLOBAL SN 03|Lab test box with problem.
ZF|P7000024900|24/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm hyd mech components|accumulator|vendor|assembly error|Vazamento de nitrogênio no acumulador|Erro instrumentação inamom
ZF|P7000024191|30/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|scm|scm|test|incorrect set up testing|SRT - GLOBAL #11 CAN BUS AND SERIAL LINE|Lab test box with problem.
ZF|100020562|22/05/2012|priority 3 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|coating plating|coating defect|scm|scm|vendor|specification not followed|BP Thunderhorse 5 O-Ring Groove on Base|BP Thunderhorse 5 O-Ring Groove on Base
ZD|100038200|19/09/2011|priority 3 |Q2|SHELL|unknown info region|ATCO NOCO NOPT NOTE|coating plating|coating defect|scm hyd mech components|outer can|vendor|specification not followed|Outer Can sandblasting|Outer Can Sandblasting
ZF|3812476|24/02/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm|scm|other external causes|customer error responsibility|Norne SCM #17  Leaking KX-coupler in lin|unknown info root_cause
ZF|7101044|02/10/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation requirement|other specify in comments|topside products|subsea power & communication unit (spcu)|documentation requirement|process step missing|Customer not notified for FAT/FI|unknown info root_cause
ZF|7104033|02/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of test equipment
ZB|7102969|19/01/2007|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|damage|damage from corrosion|scm mech w mb|other scm mechanical|vendor audit|unknown info cause_desc|ROV bucket rust.|Inadequate protection from corrosion
ZF|100037428|29/01/2008|priority 3 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT|documentation|missing certificates records|scm|scm|other causes|no noncompliance|missing batch numbers|change to batch management
Q1|7103234|19/11/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTI|scm rcm|scm|defect locations offshore field|fpso terra nova|root cause vendor|assembly fabrication test error|SCM TN04I LP Supp. Flowm. O-ring crushed|unknown info root_cause
Q3|7100320|unknown info defect_date|priority 3 |Q3|PETROBRAS|unknown info region|NOPT NOTI ATCO NOCO|hydraulic|hydraulic control valves|defect locations offshore field|campos basin|initial direct product problem|material|Upgrading of Hercules SCM 17|Wrong materials
Q3|7102969|07/12/2001|priority 3 |Q3|EXXONMOBIL|unknown info region|NOPT NOCO ATCO NOTI|scm rcm|scm|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause other|customercustomer error|SCM needs refurbishment|X-tree was accidentaly dropped
ZB|100056443|08/12/2018|priority 3 |Q1|unknown info customer_name|unknown info region|OSNO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|No power from DHI card SEM B|unknown info root_cause
Q1|7103234|21/02/2003|priority 3 |Q1|OVERALL PROJECT ROLL-UP|unknown info region|NOTI NOPT NOCO|scm rcm|scm|def. loc. testing (not int. scm)|sut (stackup test)|initial direct product problem|leakage|SCM  suspect leakage past control valves|Full test done at FKS  no fault found
Q3|7104075|10/10/2000|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTI NOCO NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|documentation|SCM FAT TPR-11190 Rev.02 requires update|Documentation update required
Q3|7103479|28/08/2001|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTI ATCO NOPT|scm rcm|scm|defect locations onshore|workshop other|initial direct product problem|leakage|Hydrocarbons in function lines & AI-card|unknown info root_cause
ZF|P6000055198|22/08/2012|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO ATCO|damage|damage due to handling|scm|scm|intercompany|dunfermline|Failure of SCM Locking Mechanism|Transport Damage
ZF|P6000088751|22/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|specification error|scm|scm|engineering|specification error|Replace damaged ribbon-cables|Ribbon cable issue  ref QN 200303504
ZF|100001156|19/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO|other defect|functional|mp quality system issues|measuring analysis & improvement|other causes damage|planning error|Material not delivered to plant|unknown info root_cause
ZF|7102969|26/04/2005|priority 3 |Q3|MOBIL EG|unknown info region|NOCO NOTE NOPT ATCO|assembly test|leakage (hydraulic air nitrogen etc.)|scm|scm|vendor|assembly error|solinoid valve failure|Solinoid valve leaking hydraulic fluid
ZF|P6000042968|09/10/2009|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|change deviation request|unknown info damage_desc|scm|scm|vendor|incorrect set up|Wrong clock freqency on TIFcards|Vendor requested setting update
ZF|P7000039672|07/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|outer can|vendor|final inspection error|Outer can não monta|101545 - KRISTIANSANDS SKRUEFABRIKK &
ZF|P7000024191|02/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|test omitted|scm|scm|test|incorrect set up testing|Man. Global #15 Can Bus $ Serial Line|Lab test box with problem.
ZF|P6000088614|08/05/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|ESRS 610 not working properly|No fault found  scrap to be safe.
ZB|100048038|07/02/2008|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|function|scm electrical|dhi pcbs|vendor|equipment malfunction|No communication with DH sensors SEM B|No communication with DH sensors SEM B
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #18 Wiring|BPTH SKOFLO SCM SN #18 Wiring
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|P6000098616|15/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (gas)|scm hyd mech components|accumulator|other causes damage|cause not found|Accumulator pressure dropped|Pressure drop on accumulator after hyper
ZB|7101172|04/12/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOTE NOCO NOPT|other defect|functional|scm|sem|other causes damage|qn cancelled|I-4H SEMA communication problems|Updated existing QN 200048719
ZE|P6000080678|28/12/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|intercompany|kongsberg|(CDM) Persehone/SCM MKII/Missing item|Missing component of SCM
ZF|100030542|11/10/2005|priority unknown info priority|Q3|CNR|unknown info region|ATCO NOPT NOTE NOCO|assembly test|do not use|scm|scm|assy|operator error|Flushing with Castrol Transaqua HT|Procedure not followed.
ZB|100006609|07/03/2012|priority 2 |Q1|PETROBRAS|unknown info region|NOCO NOPT ATCO NOTE|design|specification error|scm mech w mb|other scm mechanical|engineering|engineering error|RTA MEQS/2012/0024A|Interferência entre equipamentos
ZF|P6000083428|10/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|change deviation request|part substitution request|scm hyd mech components|hydraulic coupler|engineering|specification error|HC72 to be replaced with blind coupler|BOM needs update. Wrong PN on HC72
ZE|P6000063531|08/02/2016|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|control valve|variance|change seq. of procedure|Vigdis VEPIII rebuild Leakage|Correction fullfilled of supplier
ZF|P6000042308|22/02/2010|priority 3 |Q3|TULLOW|WEST AFRICA|ATCO NOTE NOCO NOPT|test|leakage (fluid)|scm|scm mounting base (scm|intercompany|kongsberg|Silicone Relief Valve Failure|Silicone Relief Valve Failure
ZF|P7000016420|15/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|assy|operator error|Wiring failure|unknown info root_cause
ZF|P6000043714|10/03/2009|priority 2 |Q3|PETROBRAS|GOM|ATCO NOCO NOPT NOTE|test|function|scm|scm|other causes damage|equipment malfunction|Failure of SCM to function at Tree EFAT|Failure of SCM During Tree FATInternal Project Issues Prior To FAT
ZF|P6000068912|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000001621|30/04/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|other defect|physical|scm|scm|other causes damage|damage from wear and tear|Retirada de parafuso de protection ring|Corrosão na rosca
Q1|7103233|11/03/2002|priority 3 |Q1|unknown info customer_name|unknown info region|NOTI NOPT NOCO|scm rcm|scm|defect locations offshore field|fpso terra nova|initial direct product problem|function|SCM 01/03P  SCSSV leak into HP line|unknown info root_cause
ZB|P6000042970|04/01/2010|priority 3 |Q1|TOTAL|WEST AFRICA|NOPT NOCO NOTE|test|missed operation|scm|scm|test|missed operation|Punch List SCM MAN/SIV 04|Missed operation/procedure not approved
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|NOPT NOCO ATCO NOTE|assembly test|function|scm|scm|vendor|component error|DHI FAIL TO CONNECT ON SEM B|DHI NOT CONNECTING
ZB|P6000088604|04/08/2015|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|mpcustomer complaint|noncompliance to customer requirement|test|incorrect set up testing|SMART TOOL  SPCU AND SCM PRODUCT CONFIG|SMART TOOL LOWER VERSION USED
ZF|P6000123496|24/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|test omitted|scm sem el opt component|other scm sem el opt components|test|missed operation|Missing test in HW-procedure|Two tests missing in TST60113250
ZF|P6000063531|23/03/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|test|function|scm|scm|test|damaged during testing|SCM fault on external sensors|Follow-up in QN200207958 & QN200207982
ZF|P6000108469|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extended test
ZF|P6000042968|17/01/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm el opt components|el. connector|engineering|procedure error|Incorrect wiring procedures|Mismatch between wiring procedures
ZF|P6000104111|11/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000000229|16/11/2015|priority 1 |Q3|CHEVRON|unknown info region|NOTE ATCO NOCO|damage|damage from corrosion|scm hyd mech components|locking mechanism|assy|missing operation|MMR - Loss of Material on Extension Rod|Lack of grind request after weldingLack of grind request after welding
Q3|100025735|14/11/2002|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|scm rcm|scm|defect locations onshore|workshop other|root cause engineering|material fault|Replace of bolts|unknown info root_cause
Q3|7103233|08/01/2002|priority 3 |Q3|SUNCOR CPI|unknown info region|NOTI NOPT ATCO NOCO|scm rcm|scm|ext. loc. st.johns (canada)|goods receipt|initial direct product problem|material|SCM 04 LP/HP hydraulic oil leak offshore|Hydrogen embrittlement/corrosion
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|NOTE ATCO NOCO NOPT|assembly test|missed operationassy test|scm|scm|assy|missing operation|HFT STEP CAN NOT BE EXECUTED|Simulator Not Available
ZF|100048038|10/05/2007|priority 3 |Q3|CHEVRON|WEST AFRICA|NOCO ATCO NOTE NOPT|assembly test|assembled incorrectly|scm|scm|assy|operator error|Water inside SCM after hyperbaric test|Workshop error   drain plug loose
ZF|P6000043714|07/06/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|design|specification error|scm|scm|other causes damage|qn cancelled|Missing parameter Roxar Transparent Aux|QN Cancelled
ZF|P7000024191|12/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|scm|scm|test|incorrect set up testing|CAN BUS  SERIAL LINE 2|Lab test box with problem.
ZF|P6000105542|14/08/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|physical damage|scm|scm|test|operator error|Severe damage on EC7 identified|Dropped metallic cap in EC
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|NOPT NOCO NOTE ATCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|Missing MDB Docs for BPTH SCM22|Missing MDB Docs for BPTH SCM22
ZD|7102969|03/12/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|machining|surface finish error|scm hyd mech components|outer can|vendor|specification not followed|Verification of EC repair|unknown info root_cause
ZB|7102643|19/03/2010|priority 3 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT|documentation|procedure process error|scm|scm|other causes damage|planning error|SCM 26  Åsg X-3H hyd lock HC21/22|SCM not modified for Midgard HXT.
ZF|3812476|27/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|damage|damage during testing|scm|scm|test|damaged during testing|Identified defect rectifier bridge|unknown info root_cause
Q3|7104033|28/02/2000|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTI|mechanical|outer can|defect locations onshore|workshop|initial direct product problem|marking|SCM outer can  wrongly marked with S/N|Bergen were not informed on marking
ZF|P7000024900|04/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|damage|damage during assembly|scm hyd mech components|baseplate|assy|damaged during assembly|Scratches on the base plate|unknown info root_cause
ZF|P6000080343|22/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|CV17 signal is switched SEM B|Wiring error. Operator error
ZF|100020278|02/10/2011|priority 2 |Q3|EXXONMOBIL|unknown info region|ATCO NOTE NOCO|documentation|procedure process error|fks quality system issues|quality management system|materials stores|operator error|GR not performed according to process|unknown info root_cause
ZB|P6000043122|01/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE NOCO ATCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM SSS 02|Software improvement/correction
ZF|140-141-004|10/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|damage|wear & tear|electronic boards|other eletronic boards|vendor|maintenance|Placa ARI 150 fora de padrão ROII #8 MMR|MMR Rio
ZF|P7000024900|22/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|process substitution request|scm hyd mech components|other mechanical components|other causes damage|planning error|Concession request|unknown info root_cause
ZF|3812476|13/02/2008|priority 4 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|assembly test|cleanliness|scm|scm|vendor audit|unknown info cause_desc|Cleaning of SCM in workshop during  Mob|Lack of cleaning of SCM in workshop
ZD|P6000042969|01/11/2010|priority 2 |Q2|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|vendor|equipment malfunction|HC 51 is leaking oil|Leaking coupler from vendor
ZF|P7000039672|03/12/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|cause not found|Vazamento no manifold block PS#21|BOSCH REXROTH LTDA.
ZF|100020562|24/02/2010|priority 3 |Q3|BP|GOM|ATCO NOTE NOPT NOCO|test|component error|scm|scm|test|tooling|BPTH SKOFLO Drive to Stem Command|BPTH SKOFLO Drive to Stem Command
ZF|100036232|05/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|dbi error|Correction of BOM and DWG|All docs updated  CM-500000319171
ZF|P7000000897|26/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|functional|scm|scm|intercompany|kongsberg|Test reading fail|unknown info root_cause
ZB|7102643|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|functional|scm|scm|electrical|revision error|GC 227 defect AI card (Statoil Åsgard)|unknown info root_cause
ZF|P6000120925|27/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|documentation|procedure process error|scm|scm|other causes damage|no noncompliance|PDO0 and PDO1 test was missing page 53|Test coverage is correct as is
ZF|3811810|04/12/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|continuous improvement|PN 3810872 not available in SAP|Not transferred from Procim
ZF|100052701|25/02/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|electronic boards|other eletronic boards|vendor|unknown info cause_desc|CPU init. fails at Poweron  OK & Reset|Error to be confirmed in QN200124450
ZE|P7000039672|15/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|component error|scm|scm|variance|capture mistake|RCA CDM - SCM colapsado (Hiperbárico)|unknown info root_cause
ZF|P6000103208|29/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wrong wiring of SCM|Not wired according to wiring list
ZB|100046387|05/05/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|test|function|scm|scm|test|incorrect set up testing|Guarantee claim 157 - Com fail. Sem Sy A|Com fail
ZF|P6000101955|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|13/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Trafo sem marcação de alinhamento|unknown info root_cause
ZF|7103233|21/10/2010|priority 2 |Q3|SUNCOR|unknown info region|NOTE NOCO ATCO NOPT|documentation|procedure process error|scm|scm|qa qs qi|goods receiving inspection error|SCM returned to FMCK on MMT|Goods Receiving Inspection error
ZD|P6000122574|09/10/2017|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|specification error|scm hyd mech components|outer can|vendor|specification not followed|FNCR: SCM RT/ NG SCM CLASH|Anodes protruding out from OD.
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO ATCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000001621|06/06/2014|priority 1 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|assembly|wrong part assembled|scm hyd mech components|other mechanical components|other causes damage|planning error|MMR - screw with wrong lenght|No qty enougth of original PN @Warehouse
ZF|P7000024191|17/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|test omitted|scm|scm|test|incorrect set up testing|SRT - GLOBAL #13 CAN BUS AND SERIAL LINE|Lab test box with problem.
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|ATCO NOCO NOTE NOPT|test|test omitted|scm|scm|qa qs qi|documentation error|Missing sign offs|Missing sign offs
ZF|100005667|20/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of CPI test equipment
ZF|P6000077638|13/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|other defect|part lost|scm hyd mech components|other mechanical components|vendor|missing parts|Missing O-ring P/N: 200006913|O-ring missing  not supplied
ZB|P6000042970|30/09/2010|priority 2 |Q1|TOTAL|unknown info region|NOTE NOCO NOPT|test|function|electronic boards|main boards cpu & i o|other causes damage|qn cancelled|Punch List SCM MAN/SIV 01|New SW downloaded  QN cancelled
ZD|P6000076121|21/11/2011|priority 3 |Q2|CNOOC|unknown info region|ATCO NOCO NOTE NOPT|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|clarification|Possible chips inside the HP-Config Plug|Contaminaton concern.CV sent for check.
ZF|P6000088751|09/09/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leak|scm|scm|test|damaged during testing|Water or hydr. fluid in SCM after hyperb|Fitting / oring caused leak in hyperbari
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO DLFL NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZB|P6000088604|13/08/2015|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|customer compliant|noncompliance to customer requirement|test|incorrect set up testing|XT09 SCM HP RETURN LINE TRANSMITTER NCR|unknown info root_cause
ZF|P6000043714|03/03/2009|priority 2 |Q3|PETROBRAS|GOM|NOTE NOCO NOPT ATCO|test|function|scm|scm|vendor|equipment malfunction|Failure of SCM During Tree FAT|Failure of SCM During Tree FAT
ZF|P7000039672|17/08/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|instrumentation|scm pressure transmitter|vendor|final inspection error|PT does not fit on Manifold Block|unknown info root_cause
ZF|P6000105542|24/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|HC53 has to much internal leakage|Too high internal leakage on DCV
ZF|P6000104111|11/04/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm test stand|other el opt components|test|incorrect set up testing|SRT - Value above requrement|The actual values for Node ID with name
ZF|100052134|12/07/2006|priority 3 |Q3|PETROBRAS|GOM|NOTE ATCO NOPT NOCO|assembly test|missed operationassy test|scm|scm|assy|missing operation|HFT STEP CAN NOT BE EXECUTED|no Cable Length Simulator defined
ZB|100020278|26/11/2008|priority 3 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE|test|unknown info damage_desc|scm electrical|other pcbs|other causes damage|cause not found|08-MEGI-013: RAM Warning Error|Error Message
Q1|100006609|05/02/2003|priority 1 |Q1|PETROBRAS|unknown info region|ATCO NOPT NOTI NOCO|electrical|sem el.rack|unknown info object_part_group_desc_|unknown info object_part_desc_|root cause assembly test|workshopassembly test error|El. can filled with silicone oil|unknown info root_cause
ZF|7102643|22/11/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|assembled incorrectly|scm|scm|assy|missing operation|Poor condition of SCM from KOS2 to KOS1|Incorrect and missing parts on SCM.
ZF|P7000001621|11/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|physical damage|scm hyd mech components|outer can|service :|damaged during installation|MMR - Parafusos e stab de ret. cisalhado|Impacto lateral no pino guia.
ZF|100025661|30/04/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|procedure error|scm sem el opt component|other scm sem el opt components|engineering|procedure error|Corrections to TST10001485 Rev A|Corrections to TST10001485 Rev A
ZF|100020562|20/06/2009|priority 2 |Q3|BP|GOM|ATCO NOCO NOTE|damage|damage during assembly|connectors|electrical optical|other causes damage|unknown info cause_desc|SCM11 connector damaged|unknown info root_cause
ZF|P6000063531|13/04/2015|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|design|procedure error|scm|scm|other causes damage|no noncompliance|Vigdis baseplate check valve issue.|Possible assembly error
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|design|specification error|scm|scm|engineering|specification error|Wrong type of screws used on valves|Wrong type of screw material in BOM
ZB|P6000105542|10/09/2015|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Oseberg Delta 2 Claim 280-023 SCM 20|Leaking DCV
ZF|P6000065886|07/04/2011|priority 3 |Q3|ENI|NORTH SEA|NOTE NOPT ATCO NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring error|Occasional human failure
ZB|100048038|03/12/2008|priority 2 |Q1|AGBAMI|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm electrical|processor pcbs|vendor|equipment malfunction|SCM #13 SEM A CPU151 RAM WARNING|SCM #13 SEM A CPU151 RAM WARNING
ZF|P6000105710|21/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|missed operation|scm|scm|test|operator error|Missing log files|Missing routines/check list in workshop
ZF|100035014|28/05/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|other defect|functional|scm|scm|other external causes|customer error responsibility|Deviation from mobilization scope and pr|Customer request to deviate from procedu
ZF|P7000024191|10/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
Q3|7104075|02/04/2001|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTI|electrical sensor equipment|electrical pin connetors|ext. loc. kos houston|goods receipt|root cause assembly test|workshopassembly test error|SCM EC connector installed incorectly|unknown info root_cause
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|other causes damage|qn cancelled|ANOMALIAS NA ADAPTER PLATE DE RETORNO.|unknown info root_cause
ZF|P6000104114|19/08/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leak|scm|scm|machine shop equipment|machine malfunction|Leakage on SRM with SN 2|Leakage on SRM with SN 2
ZF|7103233|21/08/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|marking|marking content error|scm|scm|assy|operator error|SCM wrong name plate after refurbishment|unknown info root_cause
ZF|P6000104112|11/04/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|SRT - Value above requrement|value above requirement
ZF|P6000064909|03/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|project|project requested unfinished shipment|ss compl. & w.over xt general|tree assembly|other causes damage|planning error|Cust Conc: No MOB carried out|unknown info root_cause
ZB|100035013|11/10/2010|priority 2 |Q1|SHELL|unknown info region|NOCO ATCO NOTE|other defect|functional|scm|scm|vendor|assembly error|Ormen Lange Claim 046 SEM A|Incorrect assembly Fibreoptic penetrator
ZF|P6000108542|24/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|instrumentation|scm chemical injection valve|other causes damage|cause not found|SCM #1 fails on CIMV|SCM #1 fails on CIMV
ZF|100038200|24/06/2008|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|specification error|test and transportation|etu smart tool hw|vendor|design error|DH2 and DH3 gauge values swapped|DH2 and DH3 gauge values swapped
ZE|100020278|02/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|customer requested|Protection Skirt Orientation|Orientation on part not acc to GA DWG
ZD|7104075|03/10/2012|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|raw material|dimensional|scm hyd mech components|outer can|vendor|specification not followed|SCM EC Bolt Holes out of tolerance|SCM EC Bolt Holes out of tolerance
ZD|P6000080343|02/08/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|raw material|defects in material|scm|scm|vendor|equipment malfunction|Hydr fluid out of silicone chk valve|Hydr fluid out of silicone chk valve
ZF|P7000001621|23/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|welding|cladding surface nde defect|ss template & manifold manifold|manifold|weld shop personnel|operator error|PORO|unknown info root_cause
ZF|P6000108984|04/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|dbi error|scm|scm|engineering|engineering error|Error in  BOM-P6000108986|Process not followed by engineering
ZB|100066325|18/05/2015|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during testing|scm|scm|other causes damage|damage from wear and tear|SCM Hydraulic leakage (Statoil SSP MKI)|Pinhole in bladder due to particles
ZF|P6000058949|26/08/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|test|leakage (fluid)|scm|scm|engineering|engineering error|Hydraulic leakage inside the module|Strength for screw too close pre-tension
ZB|P6000105542|02/02/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|scm|scm|other causes damage|cause not found|Gullfaks GSO Claim 293 DefectLVDT SUBSEA|Equipment installed  need investigation
ZB|100055600|06/03/2010|priority 2 |Q1|HELIX ESGHOUSTON STOCKING SCM MK II (15K)|unknown info region|NOTE NOCO ATCO|test|component error|scm electrical|pressure transducers|other causes damage|damage from wear and tear|LP supply PT bad output|LP supply PT bad output
ZF|P6000105542|07/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|welding|structural dimensional error|scm|scm|engineering|engineering error|NCR to Statoil - SCM manifold block|unknown info root_cause
ZF|P6000065528|26/09/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|scm|scm|engineering|procedure error|Burned PT/TT simulator`s|Operator error and procedure error
ZF|100052231|15/11/2010|priority 3 |Q3|CHEVRON|GOM|NOPT ATCO NOTE NOCO|design|procedure error|scm|scm|engineering|procedure error|Issue with HFT60015785|Issue with HFT60015785
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|100001156|20/11/2014|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|damage|damage during testing|scm|scm|test|operator error|High Voltage applied to SCM|Operator used wrong supply voltage
ZE|P6000042968|11/03/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|topside products|n a sw|causes for improvement|documentation|New config due to software upgrade.|Too many objects added to the config.
ZF|P6000108469|20/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extended test
ZF|P7000039672|03/07/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|assy|operator error|DHI sensor doesn't communicate|unknown info root_cause
ZF|P6000104111|07/05/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|marking|marking content error|scm|scm|assy|operator error|Wrong CPU mac adr (SRT)|Wrong CPU mac adr
ZF|100050383|09/05/2007|priority 4 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOPT NOTE|damage|damage during testing|scm|hydraulic valves|engineering|engineering error|Replace control valves on TORDIS|unknown info root_cause
ZF|100029062|28/04/2006|priority 2 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE NOPT|design|procedure error|scm|scm|other causes|logist.handling packing shipping error|SCM PSM ERROR|documentation correction - procedure
ZF|3794920|24/04/2007|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|assembly test|cleanliness|scm|scm|engineering|procedure error|SCM was full of calcium and rust|unknown info root_cause
ZF|100037966|03/01/2006|priority 3 |Q3|BP|unknown info region|ATCO NOCO NOTE NOPT|assembly test|function|electronic boards|other eletronic boards|assy|manufacturing engineer erorr|SCM input voltage outside limits|incorrect wiring to SFS-card  input P2.2
ZF|100048038|21/04/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT ATCO NOCO|design|procedure error|fks quality system issues|management responsibility|assy|missing operation|Pressure re-test of AGB SCM S/N 08.|unknown info root_cause
Q1|7102643|12/03/2003|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|electrical|pressure transducer|defect locations offshore field|åsgard b|initial direct product problem|function|SCM 34 ÅsgB X-1H PT Choke close malfunc.|unknown info root_cause
Q3|7105130|unknown info defect_date|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTI|mechanical|scm|defect locations onshore|montasje|initial direct product problem|cleanliness|SCM M 02|unknown info root_cause
ZF|P6000079433|04/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|obsolescence issue:&|not available|test and transportation|other scm test & transport equipment|other causes damage|cause not found|Unable to perform test according to HFT|Lack of test equipment
ZB|100056261|31/08/2009|priority 2 |Q1|MURPHY|WEST AFRICA|NOCO NOTE ATCO|test|function|scm electrical|other scm electrical|other causes damage|cause not found|SEM Common Alarm|SEM Common Alarm
ZF|P7000001621|13/12/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm hyd mech components|outer can|engineering|engineering error|Fechamento da Outer  Can Hércules SN16|Interferencia na montagem da Outercan
ZF|100058509|03/08/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|function|topside products|other topside products|other causes damage|qn cancelled|Trending Issue with LLOG ETU|Cancelled duplicate as SN 300280430
ZF|100017278|20/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|test|unknown info damage_desc|scm|scm|test|unknown info cause_desc|F&D09 Mob. is not performed  on SCM|No time for a mobilization of  the SCM
ZF|P6000066700|16/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|documentation|procedure process error|scm|scm|assy|missing parts|Missing HC in SCM OKONO|Missing coupler in HC71  SCM Okono
ZB|100020278|01/12/2009|priority 2 |Q1|EXXONMOBIL|unknown info region|ATCO NOCO NOTE|test|function|scm electrical|i o pcbs|test|damaged during testing|SCM - invalid readings|SCM - invalid readings
ZF|P6000029772|31/05/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|incorrect user documentation (customer)|scm|scm|projects|documentation error|SRM not ready for mobilization|unknown info root_cause
ZF|P6000068924|25/10/2011|priority 1 |Q3|TOTAL|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|electric products|electrical wire|engineering|procedure error|Wrong use of miniseal|Procedures need update with miniseal use
ZF|P6000068912|04/07/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm|scm|test|damaged during testing|Unstable reading from PT09 (summary QN)|unknown info root_cause
ZF|P6000074156|10/12/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|project|project requested unfinished shipment|scm|scm|test|improper handling|2810X35ZZ1 SCM not properly stored WCS|Stored Outside for Extended period
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|NOPT NOCO ATCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
ZE|P6000108984|12/02/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|(CDM-SN)SEM B PDHG FAILURE DS-02|SEM B PDHG FAILURE DS-02
ZF|P6000105542|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100048038|08/08/2006|priority 2 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT ATCO NOCO|marking|no marking|common misc general|cable|assy|missing operation|The cable idents is missing|unknown info root_cause
ZF|P6000126219|05/01/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|leak|scm hyd mech components|accumulator|assy|operator error|Internal leakage from nitrogen accumulat|Fitting not tighten with correct torque.
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Followed up in QN 200456167
ZF|100018531|02/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|electronic boards|dhi|engineering|procedure error|DHI 108 not communicating|Documentation incompatibility
ZF|P6000069056|15/12/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring on CVLP10 & CVLP11 crossed|Mixup in wiring
ZF|100052231|22/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|dbi error|scm|scm|engineering|continuous improvement|For lange skruer til  plastikk klammer|Old error in BOM/DWG corrected
ZE|P6000088604|21/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|sem bracket|projects|material error|Get parts for extra earthing rail|Extra parts for earth rail.
ZF|P7000024900|20/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|interface issue|scm hyd mech components|baseplate|materials stores|improper packaging & storage|Base plate com revestimento não conforme|unknown info root_cause
ZD|P6000088604|05/04/2013|priority 1 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|vendor|programmer error|Chevron Wheatstone SCM#1 Wiring issue| SCM#1 Wiring issue
ZF|P7000016420|27/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|Control Valve does not work properly|DCV - control valve ROTATOR
ZF|P7000020444|14/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|test|operator error|Teste hiperbárico ( Marlim 02)|unknown info root_cause
ZF|100017278|05/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage due to handling|scm hyd mech components|outer can|other causes damage|cause not found|Small notch in outercan.|Source of damage not known
ZB|P6000063531|28/04/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|electrical|component failure|object types to eng matl class|scm|electrical|other specify in comments|Vigdis FD028 SCM  failure test ALD|Most likely defect connector in SCM
ZF|P7000016420|06/08/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|MMR - DHI 205|unknown info root_cause
ZF|P6000079984|03/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|damage|damage during testing|scm test stand|other mechanical components|test|damaged during testing|Marks on baseplate mounted ECs|Follow up in ZD QN:200279919
ZF|P7000016420|13/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|function|scm|scm|test|equipment malfunction|SRT SCM P-55 SN 14|lab test box com fio soltoKongsberg - CPU without sofwareVendor issue due to other QNNão realização de teste
ZF|P6000028371|27/10/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|Missing data in flushing procedure.Sekv1|Flushing procedure not specified
ZF|100048038|05/05/2012|priority 3 |Q3|CHEVRON|WEST AFRICA|NOTE NOPT NOCO ATCO|test|function|scm|scm|test|tooling|AGBAMI SCM 42 DH SIMULATORS  ISSUES|AGBAMI SCM 42 DH SIMULATORS  ISSUES
ZF|100035013|19/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|damage during assembly|scm hyd mech components|outer can|other causes damage|damage from wear and tear|Damaged threads in outer can|Damaged thread during MMR.
ZF|100026328|26/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|damage|damage during transport|scm hyd mech components|other mechanical components|other external causes|customer error responsibility|Ovalização da protection ring  Viola 02.|MMR SCM
ZF|P7000039672|18/11/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|component error|instrumentation|scm flowmeter|vendor|equipment malfunction|HP Return Flowmeter não está lendo|2618  Flow Technology Inc.
ZF|100005667|13/11/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|Missing GA DWG on ÅSG SCM PN 100005667|Drawing updated and released
ZF|P6000093498|13/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|scm|scm|engineering|engineering error|Missing connection in wiring list|Wiring connection missed in wiring list
ZF|P6000065528|17/03/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|documentation|procedure process error|scm el opt components|scm wiring|engineering|engineering error|feil i henhold til sjematikk du600054974|Designer error
ZF|100035013|06/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm sem el opt component|other scm sem el opt components|vendor|equipment malfunction|SEM B can filled with Silicone|Leakage on insert optical penetrator
ZF|P6000104112|13/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|instrumentation|scm flowmeter|vendor|equipment malfunction|LP-R Flowmeter does not measure low flow|Incorrect counting at minumum flow
ZD|P6000109194|24/09/2014|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO|marking|no marking|scm|scm|vendor|specification not followed|QUALITY ISSUE.|unknown info root_cause
ZF|P6000104111|14/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|specification error|computer system software|sem tpu config|engineering|engineering error|Wrong  in config|unknown info root_cause
ZF|100056443|06/11/2009|priority 2 |Q3|EDISON/EDF|NORTH SEA|ATCO NOPT NOCO NOTE|test|cleanliness|scm|scm|test|operator error|SCM polluted with water/glycol|Oparator error resulted in contamination
ZF|P7000020444|20/09/2017|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOPT NOCO|test|component error|object types to eng matl class|scm|test|improper set up|MMR - PTs' Readings Out of Tolerance|unknown info root_cause
ZD|P6000104116|07/07/2014|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|vendor|specification not followed|Incorrect Revision|VL SPECIFICATION NOT FOLLOWED
ZB|7104075|17/01/2008|priority 2 |Q1|MARUBENI|GOM|NOPT NOCO NOTE|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|SCM 2  Function Line PTs  Angus 4|SCM 2 Function Line PTs Angus4
ZF|100031223|07/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|missed operation|scm|scm|test|tooling|DHI Interface test in FAT not performed.|Lack of test equipment
ZF|P7000016420|14/07/2010|priority 2 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO NOPT|raw material|defects in material|scm|scm|other causes damage|damage during transport|Danos superficias na área de vedação|unknown info root_cause
ZF|P7000000897|06/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm hyd mech components|baseplate|assy|damaged during assembly|BASE PLATE ARRANHADA NA ÁREA DO O´RING.|unknown info root_cause
ZF|100035013|12/08/2015|priority 2 |Q3|SHELL|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm sem el opt component|optical penetrator (insert)|vendor|equipment malfunction|Ormen Lange Leaking Penetrator SEM B|Leaking optical penetrator
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZB|P6000042968|25/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOCO ATCO NOPT NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 17|Software improvement/correction
ZD|7104020|16/03/2015|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|machining|inside diameter error|scm hyd mech components|outer can|vendor|specification not followed|Machining discrepancies on ROV bore|unknown info root_cause
ZF|P7000000897|28/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|outer can|vendor|packaging handling|Outer Can Scratch|unknown info root_cause
ZD|P6000057855|17/02/2010|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|electronic boards|other eletronic boards|engineering|continuous improvement|Communication failure SEM|improper anchorage of intrconnect wires
ZB|P6000103208|04/08/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|other defect|functional|scm|scm|intercompany|houston subsea|Julia SCM 05 Various|Claim rejected
ZF|100049000|23/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|coating plating|painting not applied|scm hyd mech components|outer can|vendor|coating defect|Paint Does Not Cover Exterior Weld|Paint Does Not Cover Exterior Weld
ZE|100035118|27/07/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm mech w mb|outer can|causes for improvement|process procedure not being followed|(SS)Enfield SCM Bladder|Bladder P/N200007430 defect
ZF|P6000104112|10/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Multiple loose fittings on SCM|Missed operation during assembly
ZE|P6000123882|08/11/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|marking|other specify in comments|Update Top Plate Drawing to include|Installation Eng. want marking on top.
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|design|specification error|scm|scm|engineering|specification error|Wrong type of screws used on valves|Wrong type of screws in BOM
ZE|P6000062990|01/03/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|(E) - SCM SW Verification Process Escape|unknown info root_cause
ZF|P7000016420|28/02/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|coating plating|coating defect|scm hyd mech components|locking mechanism|other causes damage|cause not found|Revestimento não conforme|unknown info root_cause
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|100049000|09/09/2009|priority 2 |Q3|BP|GOM|NOTE ATCO NOPT NOCO|test|cleanliness|scm|scm|test|operator error|BP Atlantis (DHFC) SCM 04|Wrong fluid type
ZD|P6000109194|23/12/2014|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|missing certificates records|test and transportation|scm lifting tool|vendor|documentation|REVISION ISSUE.|VL
ZF|P6000084242|15/08/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOCO ATCO NOPT NOTE|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|Rebuild to Copi South Belut from Bawal|Requested rebuilt for new project
ZF|P7000016420|31/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|instrumentation|scm pressure transmitter|test|incorrect set up testing|Teste Hiperbárico SCM P-55 SN03|Camara Hip.
ZF|P6000064910|01/06/2011|priority 2 |Q3|TOTAL|NORTH SEA|NOTE NOCO ATCO NOPT|test|function|scm|scm|test|incorrect set up testing|ILT/FLET ->MCM test  comunication error|TestCable properties not matching equipm
ZF|P7000039672|24/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|imension (tolerance)|scm hyd mech components|other mechanical components|vendor|final inspection error|Bilnd nao monta no manifold block|unknown info root_cause
ZF|P7000039672|12/01/2018|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|function|object types to eng matl class|tree_assembly|test|incorrect set up testing|Falha na leitura PT2 elet. B|unknown info root_cause
ZB|P6000079984|08/01/2014|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|documentation|procedure process error|scm|scm|engineering|engineering error|UNAPPROVED REVISION OF FAT PROCEDURE USE|UNAPPROVED REVISION OF FAT PROCEDURE USE
ZF|100020562|16/06/2010|priority 1 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|test|function|scm|scm|test|missed operation|pod serial # 17 that came off Tree 3...|Testing of the SCM
ZF|P6000080678|19/08/2014|priority 1 |Q3|PLUTO EXPANSION|unknown info region|NOCO NOTE ATCO|design|dbi error|scm test stand|hydraulic hose|engineering|dbi error|Xena - SCM Adapters not supplied|DBI missing test hoses in BOM
ZF|P6000069056|29/06/2011|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Flushing valve swapped with HC58|Incorrect assembeled flushing valves
ZF|P6000083428|04/09/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|scm hyd mech components|check valve|vendor|equipment malfunction|Failure on return check valve|Check valve slightly out of tolerance
ZF|P7000016420|12/07/2011|priority 1 |Q3|PETROBRAS|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (gas)|scm|scm|vendor|operator error|Vazamento no acumulador.|Erro de instrumentista contratado.
ZF|P6000057007|29/09/2010|priority 3 |Q3|LLOG|GOM|NOTE NOCO NOPT ATCO|test|function|scm sem el opt component|sem mech. components|intercompany|kongsberg|Bad AI board readings for SEM A|Bad AI board readings for SEM A
ZF|P6000077638|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000055213|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Incorrect screw quality used in BOM
ZF|P6000077632|12/12/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (gas)|scm hyd mech components|accumulator|assy|operator error|Gas lekage inside SCM after hyperbaric|Fittings not tighten properly.
ZF|100037966|21/01/2008|priority 2 |Q3|BP|unknown info region|ATCO NOTE NOPT NOCO|assembly test|function|scm|sem|assy|unknown info cause_desc|High pressure sensor|unknown info root_cause
ZF|P6000042969|06/07/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO NOPT|test|function|electronic boards|other eletronic boards|other causes damage|qn cancelled|micro controller error|No HW err. on CPU board  ref QN200175629
ZF|P7000024900|16/01/2012|priority 1 |Q3|SHELL|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm hyd mech components|baseplate|assy|damaged during assembly|BASE PLATE ARRANHADA NA ÁREA DO O´RING.|unknown info root_cause
ZF|100020562|27/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|engineering|continuous improvement|Missing test equipment calibration|Continuous Improvement
ZF|P6000069056|21/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|specification error|computer system software|basis e sw|engineering|engineering error|SEM A Loosing communication|unknown info root_cause
ZF|P6000039844|27/01/2009|priority 3 |Q3|SHELL|unknown info region|ATCO NOCO NOPT NOTE|test|leakage (gas)|scm|scm|assy|operator error|Nitrogen leakage in hyperbaric|fitting not tightened enough to seal
ZF|P7000024191|27/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|test omitted|scm|scm|test|incorrect set up testing|SRT GLOBAL 04 LABTEST BOX|Lab test box with problem.
ZE|P6000126219|03/11/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm hyd mech components|other hydraulic components|test|procedures not followed|SCM  Missing test of new PT during FI|Changed operator during test.
ZE|P6000076121|24/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|SCM Mal function|SCM mal function
ZF|100020562|18/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm hyd mech components|control valve|other external causes|customer error responsibility|High LP DCV Leakage Rate|unknown info root_cause
ZD|P6000093501|14/11/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|VOLTAGE OUT OF CRITERIA|HFT issue
ZF|P6000122626|21/06/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|cleanliness|ss compl. & w.over xt general|tree assembly|other causes damage|cause not found|SCM fluid cleanliness verification|unknown info root_cause
ZB|100050519|04/02/2010|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|assy|manufacturing engineer erorr|Faulty readings on sensors on SCM|Faulty Readings on sensors
ZE|100027228|31/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|Wrong DHI table in HFT-0000020536|Procedure updated
ZF|P1000018406|13/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|procedure error|scm|scm|other causes damage|qn cancelled|Hydraulic fluid in silicone sample|QN will be canceled Duplicate
ZF|P6000147469|13/12/2017|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|damage|damage during assembly|object types to eng matl class|scm_assy|assembly|damaged during assembly|Unable to get communication with EC7 har|unknown info root_cause
ZB|100020278|06/03/2009|priority 2 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|valves general|chokes|other causes damage|cause not found|09-MEGI-019: Unauthorized choke movement|09-MEGI-019: Unauthorized choke movement
ZE|P6000039844|12/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|Lp adapterplate need adapter for tube.|Wrong part used in BOM.
ZB|100067526|29/06/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|other defect|functional|scm|scm|other causes damage|cause not found|GFC well M-4H LP1/LP2 does not operate|Equipment Subsea- Cause not found
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO NOTE ATCO NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #16 Wiring|BPTH SKOFLO SCM SN #16 Wiring
ZF|P7000039672|05/05/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|part lost|electric products|electrical connector|vendor|specification not followed|Falta de parafusos do kit p/ Conector|unknown info root_cause
ZF|P6000069056|04/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|wrong test procedure used|scm hyd mech components|other hydraulic components|test|operator error|Pressure test: High pressure in LP lines|HP pressure in LP lines.Operator error
ZF|P6000069820|16/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wrong testplug on SCM|Wrong test plug mounted for use inhouse
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|vendor|operator error|ANOMALIA NA ROSCA DA ADAPTER PLATE|Acabamento de rosca não ok
ZF|P6000068912|05/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Loose bolts on outercan SCM.|Loose bolts  follow up RCA 200323341
ZF|100035013|26/05/2009|priority 2 |Q3|SHELL|unknown info region|NOTE NOCO ATCO|test|component error|topside products|filter|other external causes|unknown info cause_desc|unknown info notification_desc|unknown info root_cause
ZF|P6000105542|16/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Too high leakage|Too high and unstable leakage from DCVs
ZF|P6000083428|10/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|change deviation request|part substitution request|scm|scm|other external causes|customer error responsibility|HC72 to be replaced with blind coupler|Client request  rebuild SCM  remove HPI
ZF|P7000039672|20/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Válvula com vazamento no Leakage Test|1659 - Oceaneering Rotator AS
ZF|P6000104112|10/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|wrong part assembled|scm|scm|engineering|specification error|Change name plate|New name plates are delivered
ZF|P6000088614|16/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|electronic boards|main boards cpu & i o|vendor|assembly error|PDO 0 shows 17V when powered OFF on SEMB|Penetrator leakage  followup QN200411902
ZF|P6000079984|30/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|topside products|n a sw|intercompany|kongsberg|ASSY/EXXON (HSE)/Software/ESRS FILE|ASSY/EXXON (HSE)/Software/ESRS FILE
ZF|P6000105542|06/08/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage during testing|scm|scm|engineering|engineering error|SCM router cards damaged|Incorrect XT BOM  insufficient assy doc
ZF|P7000024191|05/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|test omitted|scm|scm|test|incorrect set up testing|Man. Global #17 Can Bus & Serial Line|Lab Test Box with problem.
ZF|P7000016420|03/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|missed operation|test and transportation|other scm test & transport equipment|test|incorrect set up testing|SRT SCM P-55 SN 08|lab test box com fio solto
ZF|P6000076121|14/01/2011|priority 2 |Q3|LIU HUA 4-1|unknown info region|NOPT NOCO ATCO NOTE|project|project requested unfinished shipment|scm|scm|projects|material error|Production stop HUSKY LIWAN|Production stop H.Liwan to Liu Hua SCMs
ZF|P6000039844|22/08/2018|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|electrical|other specify in comments|object types to eng matl class|scm|test|incorrect set up testing|Missing test equipment / CR request|unknown info root_cause
ZF|P6000116166|04/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm el opt components|el. connector|vendor|equipment malfunction|Bad connection on EC6 pin 3|Followed up in QN 200430835
ZF|P6000132097|31/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|control valve|other causes damage|no noncompliance|Too big leakage during SCM leakage test|Changed out due to obsolence
ZF|100052231|01/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|dbi error|scm|scm|engineering|engineering error|Change Thread Bush and move Blind plug|Error in BOM and drawing
ZF|P6000065886|09/02/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Faulty procedure|Test&Flushing procedure faulty
ZF|P7000016420|03/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|imension (tolerance)|scm hyd mech components|outer can|vendor|material error|Furo desalinhado|Furo não estava casando
ZB|P6000028371|26/04/2010|priority 3 |Q1|SHELL|GOM|ATCO NOTE NOCO|test|component error|scm electrical|processor pcbs|vendor|equipment malfunction|MPFM Abnormal Readings|MPFM Abnormal Readings
ZF|P6000079433|09/11/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE ATCO NOPT NOCO|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips inside the HP-Config Plug|Plugs not cleaned by supplier.
ZD|7101463|15/06/2010|priority 3 |Q2|EXXONMOBIL|unknown info region|NOPT NOTE ATCO NOCO|damage|damage due to handling|scm|scm|other causes damage|damage from wear and tear|Deep scratch in SCM 7 EC sealing surface|Deep scratch in SCM 7 EC sealing surface
ZE|P6000073687|28/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|drawing error|scm|scm|projects|documentation error|Missing info on GA dwg.|Missing info on GA drawing
ZE|P6000068918|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update MCM HFT - Luanda Workshop|Update is followed up in QN 200439169
ZB|100036936|26/04/2017|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|other causes damage|damage from wear and tear|LP suply flowmeter failure (SCM URD)|lowmeter(FM)failure due to contamination
ZF|P7000039672|12/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Vazamento na adapter plate de LP|123643 - BOSCH REXROTH LTDA
ZF|P6000079984|14/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|interface issue|scm|scm|vendor|specification not followed|no gap between Guide Rails and Outercan|Guide rails slightly out of tol.accepted
ZE|P6000104116|15/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|O-ring sealing surface fault|DWG updated ref ECN 6180458
ZE|P6000079433|02/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|imension (tolerance)|electronic boards|comm.link (power line)|engineering|engineering error|Not able to mount bolt.|BOM not aligned with ASM instruction
ZF|P1000018406|18/04/2011|priority 3 |Q3|BP|GOM|NOTE NOPT NOCO ATCO|coating plating|coating defect|scm|scm|other causes damage|no noncompliance|Unacceptable part|Unacceptable part
ZE|P6000091085|26/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|process procedure ineffective|Discrepancies in SW Release dates & SPC|Manual process failed
ZF|P6000105542|05/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Too high leakage during leakage test|DCV leakage followed up in ZD   ZE QN
ZF|100066465|03/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|electronic boards|other eletronic boards|test|damaged during testing|PT/TT 4 not working properly|Board overstressed  ref RCA task
ZB|100033987|22/11/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm|scm|other causes damage|cause not found|Warranty claim 256|unknown info root_cause
ZB|100036232|16/12/2014|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|projects|material error|Issue with Bergen refurbished SCM|unknown info root_cause
ZF|P7000024191|01/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|test omitted|scm|scm|test|incorrect set up testing|SRT Global 9 can bus and Serial Line S2|Lab test box with problem.
ZF|P6000105542|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000079984|24/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|topside products|other topside products|intercompany|kongsberg|Test Error/Exxon/SCM/DownholeCardIssues|Test Error/Exxon/SCM/DownholeCardIssues
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #13 Wiring|BPTH SKOFLO SCM SN #13 Wiring
ZF|P6000067533|11/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|wrong part assembled|scm hyd mech components|control valve|engineering|dbi error|Wrong screws for mounting covhp|BOM incorrect.M8 screw instead of M10
ZF|P6000028371|30/11/2010|priority 2 |Q3|SHELL|GOM|NOCO NOTE ATCO NOPT|test|function|electronic boards|main boards cpu & i o|assy|damaged during assembly|Lost measurement on PT24.|Accidental operator failure
ZB|100035014|23/06/2010|priority 3 |Q1|STATOIL|unknown info region|NOPT NOPR NOTE OSTS|other defect|functional|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|WN990### - SCM Manifold TT Discrepancy|SCM card defaulted
ZF|100035013|03/01/2010|priority 2 |Q3|SHELL|unknown info region|NOCO NOTE|other defect|functional|scm|sem|projects|material error|Communication failure on SEM|SCM failure  SCM changed
ZF|P7000039672|16/07/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|scm sem el opt component|sem cable & wiring|intercompany|kongsberg|SEM A do SCM com Leitura Divergente|unknown info root_cause
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL ATCO NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P6000105542|13/05/2015|priority 2 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|assy|operator error|Hydraulic leakage manifold block/adapter|Contamination below o-ring  caused leak
ZF|P6000104113|23/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|instrumentation|chemical injection valve|test|missed operation|CANbus CITV fault|Wiring updatet and checked OK
ZF|100048038|10/04/2009|priority 4 |Q3|CHEVRON|WEST AFRICA|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Unable to Hold Pressure|Unable To Hold Pressure
ZF|P6000042308|02/06/2009|priority 3 |Q3|TULLOW|WEST AFRICA|ATCO NOPT NOTE NOCO|documentation|procedure process error|scm|scm|other causes damage|no noncompliance|Witness Notification To Customer Missed|Witness Notification To Customer Missed
ZF|P7000024900|11/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|scm|scm|test|operator error|SRT - BC-10  #37 Communication Failure|Download failure
ZB|P6000063531|09/10/2017|priority 1 |Q1|unknown info customer_name|unknown info region|DLFL NOCO NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Power supply error|unknown info root_cause
ZD|7100320|02/05/2016|priority 3 |Q2|PETROBRAS|unknown info region|DLFL NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|MMR - Couplers leakage|unknown info root_cause
ZF|100035013|22/02/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Incorrect wiring of LP Changeover Valve|Operator Error
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|unknown info region|NOCO NOTE ATCO|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Bug Fix
ZF|P6000116166|28/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT|other defect|physical|common misc fittings|other|other causes damage|cause not found|3 o-ring on hydraulic fitting is damaged|Bad O-rings followed up by Common
ZE|P6000088604|19/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(SS) Verification of comm issue of SCM|Verification of comm issue of SCM
ZF|P7000016420|09/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|scm|scm|test|incorrect set up testing|SRT SCM P-55 SN 10|lab test box com fio solto
ZF|P6000104112|30/08/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|leak|object types to eng matl class|scm|assy|operator error|SCM ISSUED HAVE SILICON|SCM ISSUED HAVE SILICON
ZF|100048038|24/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Too high internal leakage Agbami SCM 44|Too high internal leakage on DCV 3
ZB|P6000064911|29/07/2014|priority 3 |Q1|TOTAL|NORTH SEA|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|vendor|material error|Laggan Claim 070 - SRM failure|Leaking optical penetrator
ZF|P7000039672|22/05/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|electrical|component failure|object types to eng matl class|scm|intercompany|kongsberg|SNR  VARIABLE BELOW EXPECTED VALUE|unknown info root_cause
ZF|100037965|30/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|engineering|dbi error|inconsistent valve signature|Wrong flow restrictor in BOM
ZF|P7000039672|05/09/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|dbi error|object types to eng matl class|kits|engineering|ecn change|ECN  7090703    PN  P7000017838|Error-concept/calculation
ZF|100056443|03/10/2018|priority 3 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|project|project requested unfinished shipment|scm|scm|service :|improper job preparation|LD-Delay on Delivery Kongsberg MS30 SCM|Delay in Production
ZF|100055762|13/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|missed operation|scm|scm|test|tooling|Testing not according to company PO|Lack of test equipment
ZB|7103553|13/10/2017|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|scm|scm|software|other specify in comments|MDS Manifold SCM Comms Failure Support|Specification not clear enough
ZF|P1000018406|24/06/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|valves general|check valves|test|damaged during testing|BP DHFC Failed Check Valve|BP DHFC Failed Check Valve
ZF|P7000020444|19/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|component error|scm sem el opt component|optical penetrator (insert)|test|operator error|value does not meet accepted criteria|Due to a different set up
ZF|P6000104116|28/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|machining|surface finish error|scm hyd mech components|other mechanical components|vendor|specification not followed|O-ring surface too rough|Sealing Surface sandblasted  ZD200410470
ZB|P6000102554|03/02/2014|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|fabrication shop personnel|operator error|Heidelberg - Anadarko Claim SCM 01|Operator error
ZF|100059660|16/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|test|function|scm|scm|engineering|engineering error|Problems receiving flow meter values|Adapter plate for Flowmeter design error
ZD|100025661|12/02/2014|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|other defect|physical|scm hyd mech components|outer can|vendor|operator error|Damage to outer can’s EC ports|unknown info root_cause
ZF|100035013|23/06/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Silicone inside both SEM A and B|Optical penetrator leaking
ZE|P6000088751|21/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Update KS200e SW to 610.0|To Update KS200e SW to 610.0
ZB|3787101|10/03/2017|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|electrical|wiring short|scm|scm|engineering|ecn change|MCM Quality of Internal Wiring|Design obsolete and replaced
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000081371|17/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|machining|thread error|scm hyd mech components|baseplate|vendor|tooling|Checkvalves doesn't fully enter|Bad threads in baseplate (for chk valve)
ZF|7104670|06/07/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CIDV 1 failed during Mobilization|unknown info root_cause
ZF|100056261|23/08/2010|priority 3 |Q3|MURPHY|WEST AFRICA|NOCO NOTE ATCO NOPT|documentation|procedure process error|stage gate review|quality documentation|engineering|continuous improvement|Incomplete databook|Engineering Sign offs required
ZF|7100320|29/04/2016|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|vendor|equipment malfunction|MMR - Couplers leakage|unknown info root_cause
ZF|100056443|01/09/2009|priority 1 |Q3|EDISON/EDF|NORTH SEA|NOCO ATCO NOPT NOTE|test|cleanliness|scm|scm|test|operator error|Contaminated oil in SCM  TFHPU  SCMTS|Operator used wrong fluid
ZF|100036936|29/09/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|engineering|engineering error|Documentation Norne Sat|Wrong P/N linked to Procedure
ZE|P6000080678|07/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM) Xena - SCM HFT Procedure|HFT Procedure Not Customized for Scope
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|machining|angle error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|P6000067533|07/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|missed operation|scm|scm|engineering|procedure error|missing flushing lines  in the procedure|Missing steps in procedure.Human error
ZF|P6000126219|15/08/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|electrical|functional|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|electrical|other specify in comments|Megging of EC 2|Moisture on components.
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO DLFL NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|engineering|ecn change|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000039672|03/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|other mechanical components|other causes damage|damage during transport|protection ring ovalizada|unknown info root_cause
ZF|100005667|11/02/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|Åsg F&D 10 Break up SCM w/Override tool|Procedure needs updating
ZF|P7000039672|12/01/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|scm hyd mech components|hydraulic pressure intensifier|vendor|equipment malfunction|Falha de leitura no PT 03 da Sem A|unknown info root_cause
ZF|3794920|26/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|obsolescence issue:&|end of life (eol) (obsolete)|scm sem el opt component|other scm sem el opt components|unknown|unknown|Error on alternative program (EEPROM)|EEPRPOM Failure.
ZE|P6000084242|02/05/2012|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Fault in procedure TST60075261|TST proc. fault in flushing LP\HP lines
ZF|P6000104116|28/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|Holes for lifting bolts not aligned|Paint and hole aligment error
ZB|P6000105542|12/08/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|damage|damage during assembly|scm|scm|fabrication shop personnel|operator error|GSO Claim 001 SCM Router cards|Wrong connector installed on XT
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000098616|22/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|other causes damage|planning error|Bad twisting of wires|Bad twisting of wires
ZF|100037427|27/10/2011|priority 1 |Q3|TOTAL|unknown info region|NOCO NOPT ATCO NOTE|assembly|imension (tolerance)|scm|scm|engineering|dbi error|Parts not according to BOM/DBI|unknown info root_cause
ZF|P6000031350|20/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|physical damage|scm|scm|assy|damaged during assembly|Damaged wire|Wires pulled out from penetrator RCA TBA
ZF|P7000039672|01/02/2018|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|damaged during testing|object types to eng matl class|scm|test|damaged during testing|SCM colapsado durante teste Hiperbárico|unknown info root_cause
ZF|P7000020444|29/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|missed operation|scm|scm|intercompany|kongsberg|SRT com desvios|Documento não marcado como HP
ZF|P6000058949|03/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|Engineering error  5 WHY in QN:200186565
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|DWG error
ZB|140-141-004|06/12/2012|priority 2 |Q1|PETROBRAS|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|RTA MEQS 2012/0016A|unknown info root_cause
ZF|P6000104114|21/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|design|drawing error|scm hyd mech components|baseplate|engineering|dwg error|Update of baseplate on SRM|Wrong position of silicone check valve
ZF|P6000104112|10/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000098616|10/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|function|instrumentation|scm pressure transmitter|other causes damage|cause not found|PT5 is showing high value at zero pressu|PT value increaseing  follow up200341036
ZF|P6000098616|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|3787102|26/02/2008|priority 4 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|engineering|engineering error|Guarantee claim 146 - Leakage  valves|Leakage on solenoid valves
ZF|P7000039672|11/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|imension (tolerance)|scm el opt components|el. connector|vendor|final inspection error|Tygon Hose com diametro maior|unknown info root_cause
ZF|P7000001621|18/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm hyd mech components|hydraulic tubing|other causes damage|cause not found|Fechamento da Outer can Hércules #19|decorrente do processo de reparo
ZF|P6000065886|23/05/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|damaged during testing|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|test|damaged during testing|CCB Board in SESI burned and shorted|short in the CCB board in SESI
ZF|P6000103208|19/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|EC 1 loose screws|Screws not torqued as specified
ZF|P6000050867|05/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|documentation|procedure process error|electric products|electrical components|engineering|procedure error|TST was not released in TCE|TST was not released in TCE
ZF|100031193|21/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|assembly|wrong part assembled|scm|scm|projects|material error|Mudança de plaqueta de identificação|unknown info root_cause
ZB|100034629|04/10/2018|priority 3 |Q1|unknown info customer_name|unknown info region|NOPR NOPT OSTS NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Fiber A&B is possibl. switch in SCM(OSB)|unknown info root_cause
ZF|P6000028371|08/12/2010|priority 2 |Q3|SHELL|GOM|NOCO NOTE ATCO NOPT|damage|damage during assembly|scm hyd mech components|outer can|assy|operator error|No reading from WLD|WLD wire damage during assy of outercan
ZF|P6000069056|15/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|change deviation request|conversion approval|scm|scm|projects|documentation error|SCM – return line compensator|Water ingress onto hyd.system(NCR)
ZE|P6000074156|29/07/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|HFT60070348 - Final Prep of ESRS600|Chapter missing in procedure
ZF|100050519|18/09/2013|priority 1 |Q3|MOHO BILONDO|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|compensator|test|operator error|SCM Damaged During Training|Lack of training/operator error
ZF|100033987|21/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|test|unknown info damage_desc|scm|scm|test|unknown info cause_desc|F&D09 Mob. is not performed  on SCM|No time for a mobilization of  the SCM
ZF|100055762|01/02/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|Test procedure missing information|Old procedure  voided and replaced
ZD|P6000122574|29/03/2018|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO|marking|no marking|object types to eng matl class|scm|engineering|specification error|Revision Issue|NVL ENGINEERING ERROR
ZE|P6000088604|19/12/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Wheatstone SCM  Communication error|unknown info root_cause
ZF|100054943|29/09/2008|priority 1 |Q3|WOODSIDE|unknown info region|NOCO NOTE ATCO NOPT|other defect|functional|scm|scm|assy|lack of training|CVLP failes during hyperbaric test|workmanship failure
ZB|100017997|04/09/2009|priority 2 |Q1|BP|GOM|NOTE ATCO NOCO NOPT|damage|damage during assembly|scm hydraulic|compensators|vendor|assembly error|Ruptured Bladder|Damaged Bladder
ZD|P6000079433|12/06/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOTE ATCO|procurement|vendor did not complete required work|hydraulic products|relief valve|intercompany|kongsberg|LP return leaking on SCM|Smart return on SCM faulty -
ZF|P6000122574|26/09/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|CHECK VALVE/ DRAWING INCONSISTANT|Installed wrong by Technician
ZF|100036232|16/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|assembled incorrectly|scm|scm|assy|dwg error|Issue with FMC Norway refurbished SCM|Lack of GA DWGWorkshop technician failure
ZB|100018082|10/04/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|obsolescence issue:&|not available|scm|scm|other causes damage|cause not found|Warranty claim 259-Malfunct.SEM B SUBSEA|unknown info root_cause
ZE|100020562|27/05/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|engineering|continuous improvement|Missing test equipment calibration|Continuous Improvement
ZF|P7000024191|23/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|other causes damage|cause not found|Coupler de supply(HC 2) vazando - SCM 10|Sem evidência da causa
ZF|P6000132097|04/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Too big leakage during SCM leakage test|Too high internal leakage on COVHP
ZB|P6000122574|16/08/2017|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|electrical|component failure|object types to eng matl class|scm|electrical|bad part|Suncore Terra Nova SCM #3 Kulite PT fail|PT failure
ZD|100056261|19/05/2008|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|No DBI for part number|No DBI for part number
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO|design|specification error|scm|scm|engineering|specification error|Wrong type of screws used on valves|BOM incorrect.M6 A4-80 to M6 inconell718
ZF|P6000058949|05/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage during testing|scm|scm|test|operator error|To high pressure on the DIACS return|Return hose not properly connected
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOCO ATCO NOPT NOTE|design|dbi error|scm hyd mech components|other mechanical components|engineering|specification error|Wrong Bill Of Material and wrong parts|Coupler Interface on m.block (spc error)
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|unknown info region|ATCO NOCO NOTE NOPT|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Bug Fix
ZF|P6000028371|23/01/2008|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of COV and strainer|DCV/COV with Cobalt pilot ball
ZD|P6000028371|05/01/2015|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|damage|damage from corrosion|scm hyd mech components|outer can|vendor|operator error|Damage EC ports|unknown info root_cause
ZF|100020562|28/10/2009|priority 2 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|test|function|scm|scm|test|missed operation|Return Compenstator Test SCM 24|Return Compenstator Test SCM 24
ZF|P6000123495|25/04/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|component error|instrumentation|scm pressure transmitter|engineering|engineering error|HP Supply aproximately 19bar|PT has to be replaced
ZF|100067526|19/08/2014|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|test|cleanliness|scm hyd mech components|accumulator|vendor|specification not followed|MMR Gullfaks 5 Accumulator contamination|Accumulator contains wrong fluid
ZF|P6000074156|15/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|wrong test procedure used|scm|scm|test|operator error|Shell West Boreas XT # 4 - SCM|SCM Overpressure
ZF|P7000039672|04/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|common misc seals|nonmetallic|materials stores|no noncompliance|Oxidação na SEM bracket|1553 - AS Koberg
ZF|P6000101955|09/07/2014|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|other defect|physical|scm|scm|other causes damage|qn cancelled|3- Silicone leakage on Primary SCM S/N 3|unknown info root_cause
ZF|P6000076121|04/01/2012|priority 1 |Q3|CNOOC|unknown info region|NOTE NOPT NOCO ATCO|other defect|functional|scm|scm|intercompany|kongsberg|(SS) Frequency and Software issue in SCM|Frequency and Software issue in SCM
ZF|P7000001621|09/07/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|MMR - DHI boards do not communicate|unknown info root_cause
ZB|100035118|08/01/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|leakage (fluid)|scm|scm|intercompany|kongsberg|WEL  Test Failure  L1 Escape|unknown info root_cause
ZF|100056443|23/02/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|NOCO ATCO NOPT NOTE|design|specification error|scm|sem|engineering|engineering error|Addition of Grounding Power-can|Design improvement for safety precaution
ZF|100055762|09/10/2010|priority 4 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOCO NOTE|documentation|procedure process error|scm|scm|engineering|dbi error|SCM inter. accumulat.not charged|unknown info root_cause
ZF|P6000069820|31/10/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|scm sem el opt component|other scm sem el opt components|variance|capture mistake|COPI Platform Comms Startup Shutdown|Unable to establish communication
ZD|7104075|16/01/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO|damage|damage due to handling|scm hyd mech components|outer can|vendor|operator error|Damage EC connectors on outer can|unknown info root_cause
ZF|100059660|09/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|function|scm|scm|engineering|engineering error|Problems receiving flow meter values|BOM and DWG error.Adapter plate design
ZB|100025661|27/04/2010|priority 2 |Q1|SHELL|GOM|ATCO NOCO NOTE|test|function|scm electrical|special electronics.|test|tooling|Shell Llano 2 Topsides|Shell Llano 2 Topsides
ZF|P7000039672|04/11/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|wrong part assembled|scm sem el opt component|other scm sem el opt components|assy|operator error|Troca de montagem eletrônica|unknown info root_cause
ZF|100050519|13/05/2013|priority 2 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE|test|function|electronic boards|dhi|other causes damage|cause not found|Down Hole Gauge Loss of communication|Follow-up in common ZE QN 200369318
ZD|7103233|16/09/2010|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|incorrect certificates records|scm|scm|intercompany|kongsberg|Lloyds release note missing (IRN)|unknown info root_cause
ZF|100038200|18/07/2011|priority 3 |Q3|SHELL|unknown info region|NOCO NOTE ATCO NOPT|damage|damage during assembly|scm hyd mech components|outer can|intercompany|kongsberg|EC Seal Surface Welding Issue|EC Seal Surface Welding Issue
ZF|P7000039672|25/03/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|assembled incorrectly|scm hyd mech components|locking mechanism|vendor|operator error|Ext. Rod com imperfeição superficial|unknown info root_cause
ZE|P6000055605|28/03/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Update TST10051297|unknown info root_cause
ZB|100036936|02/11/2014|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|other defect|functional|scm sem el opt component|other scm sem el opt components|test|operator error|Communic.problem-connecting UDF to Norne|Human error
ZF|P6000043714|02/07/2010|priority 2 |Q3|PETROBRAS|GOM|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm|scm|other causes damage|cause not found|Control fluid in silicone sample|Cause for leakage not found
ZD|100049000|15/06/2010|priority 3 |Q2|BP|unknown info region|NOPT ATCO NOCO NOTE|damage|damage during assembly|scm|scm|assy|damaged during assembly|SCM ASSY|SCM ASSY
ZE|7103553|12/10/2017|priority 2 |Q3|SHELL|unknown info region|NOPR OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM  Wrong communication frequenzy|unknown info root_cause
ZF|P1000018406|30/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|procedure error|hydraulic distribution|mqc|assy|missing operation|Damage: BP/DHFC/MQC Sheared Pin|MQC Sheared Pin
ZF|7102643|08/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO ATCO NOPT NOTE|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #17 Wiring|BPTH SKOFLO SCM SN #17 Wiring
ZF|P1000018406|27/04/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|damage|damage due to handling|hydraulic products|multi quick connector (mqc)|materials stores|improper handling|MQC Outboard Assembly|Warehouse Improper Storage of  MQC
ZF|P7000000897|03/11/2011|priority 1 |Q3|SHELL|unknown info region|NOTE ATCO NOPT NOCO|assembly|wrong part assembled|scm hyd mech components|baseplate|vendor|operator error|Wrong ECs Marking on base plate.|USILIDER - BASE PLATE
ZF|P6000121268|02/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm|scm|engineering|procedure error|SCM flow restriction error|Missing information in procedure
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|DLFL NOCO ATCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|100049000|16/05/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|coating plating|incorrect colour coating|scm hyd mech components|outer can|vendor|coating defect|Incorrect coating on outer can|unknown info root_cause
ZF|P6000088604|10/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|function|scm|scm|other causes damage|no noncompliance|Short-circuit|Illegal operation allowed in debug SW
ZF|P6000055605|15/02/2011|priority 3 |Q3|SHELL|GOM|ATCO NOTE NOCO NOPT|test|cleanliness|scm|scm|assy|operator error|Do not get vacuum on SCM|Tie wrap found in El.Bracket caused leak
ZB|100005667|08/02/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|test|leakage (fluid)|scm hyd mech components|outer can|test|damaged during testing|Leakage from module during MOB for Y-1H|unknown
ZE|P6000116166|19/12/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm el opt components|scm wiring|projects|material error|Wiring fault CAN-bus|Wrong SESI used  SESI not available.
ZF|P7000000897|21/09/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|coating plating|coating not applied|scm|scm|other causes damage|planning error|Revestimento de item - mecanismo de trav|Wrong coating
ZE|P6000064909|27/10/2014|priority 2 |Q3|TOTAL|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|SCM HFT amendments|Continuous improvment
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|Design error on DWG
ZB|100018082|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|damage|damage due to handling|scm|scm|other external causes|customer error responsibility|Warranty claim 225-Mikkel|Damage to equipment
ZE|P6000088751|17/04/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSNO OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CDM -GWF-2 SCM - PT Sensor Display Error|unknown info root_cause
ZF|P6000055605|07/05/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|leak|scm|scm|assembly|improperly installed|SCM  Water in silicon after hyperbaric|Silicone hose in hyperbaric chamber.
ZF|P7000024191|21/09/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|test omitted|scm|scm|test|incorrect set up testing|SRT Global 8 can bus and Serial Line S2|Lab test box with problem.
ZF|100035013|27/05/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Procedure needs to be revised|HFT procedure corrected
ZB|100069556|30/09/2015|priority 1 |Q1|SUNCOR|unknown info region|DLFL ATCO NOTI NOCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM LEAKING FLUID|unknown info root_cause
ZB|100064910|31/05/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|functional|scm|scm|other causes damage|cause not found|Åsg BB071 SCM failed on rig after mob DT|Short circuit component on SCM
ZF|P7000039672|27/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|damage|damage from corrosion|scm hyd mech components|other hydraulic components|vendor|equipment malfunction|Filtro com sinal de oxidação|unknown info root_cause
ZF|100052701|19/09/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage from corrosion|scm|scm|other causes damage|damage from wear and tear|Corrosion on SCM|Left in yard and not returned to Custome
ZF|P6000103208|12/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|scm|scm|test|damaged during testing|Test Error/Exxon/SCM/Exposed to Short|Test Error
ZF|P6000058949|01/12/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation requirement|procedure process error|scm|scm|documentation requirement|input requirements incorrect ambiguous|DHI205 test contains misleading info|unknown info root_cause
ZF|P6000104112|11/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm|scm|vendor|clarification|Have no link up on EC3 etherscoptest.|Followup towards supplier: QN200416823
ZB|100017278|27/02/2008|priority 4 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|documentation|missing user documentation (customer)|scm|scm|other causes damage|planning error|Reconstruction of equipment|Lack of  communication lines
ZF|7105597|30/04/2010|priority 2 |Q3|PETRO SA  MOSSEL BAY|unknown info region|ATCO NOTE NOPT NOCO|other defect|functional|manufacturing quality general|fixtures|manufacturing engineering|me routing|Deviation on compensation system|Couse is not  to CS
ZE|P7000039672|28/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|assembly|damaged during lifting|MMR - Screw/Securing Plate from El. Can|unknown info root_cause
ZF|P7000039672|20/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|assembled incorrectly|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|assy|no noncompliance|Teste de Hélio não aprovado.|unknown info root_cause
ZF|P6000088751|26/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hyd mech components|compensator|assy|operator error|Broken silicone bladder compensator|Installation error of compensator.
ZD|100048038|29/05/2008|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|vendor|specification not followed|No DBI referencing this material|No DBI Available
ZF|P6000031350|28/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|functional|fks quality system issues|product realization|materials stores|improper packaging & storage|Equipment located outside of warehouse|Equipment not stored according to proced
ZF|P6000105708|17/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|function|scm el opt components|scm wiring|assy|damaged during assembly|No reading on EC3 pin 9 and 10|Workmanship during wiring  TBC in RCA
ZF|7102643|17/03/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|test omitted|scm|scm|assy|lack of maintenance|F&D Mobilization not performed on SCM|Conditionbased maintenance not performed
ZF|P7000020444|19/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm hyd mech components|hydraulic coupler|other causes damage|damage during transport|coupler´s não montam|MabotecDesvio oriundo de tranporte na fábricaSolicitação de concessão
ZF|P7000016420|26/10/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|machining|inside diameter error|scm hyd mech components|locking mechanism|vendor|material error|medida da screw fora da tolerância|Montagem Issue
ZF|100035013|06/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|cleanliness|scm hyd mech components|other hydraulic components|other external causes|customer error responsibility|MEG present in the Hydraulic system|ROXTHI operation in 2012  ref. 300346456
ZF|P6000105542|03/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|100054943|10/06/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|(CDM)WOODSIDE KBSB SCM - HFT ISSUES|HFT issues
ZF|P6000058949|11/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Wrong type of screws used on valves
ZF|100049000|12/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|leakage (fluid)|scm|scm|other causes damage|cause not found|DCV leakage outside acceptance criteria|Specification to be updated
ZF|100052701|07/05/2013|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Tyrihans 2 Leakage|Screws not torqued on adapter plate.
ZF|P6000104112|18/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|engineering|engineering error|Update KS200e SW for Egina|Com. functionality which was not cons.
ZF|P6000088751|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000063531|27/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|scm|scm|test|tooling|Acoustic Leak Detector test in HFT|Lack of functional CPI test equipment
ZF|100017278|12/05/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|physical|scm sem el opt component|other scm sem el opt components|assy|damaged during assembly|Silicone in SEM. Reason unknown|Silicone found inside SEM during RIT
ZF|P6000104116|17/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation requirement|procedure process error|object types to eng matl class|iwcm_assy|documentation requirement|ambiguous unclear|POWER TEST FOR SCM ISSUE with Procedure|unknown info root_cause
ZF|P7000016420|05/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|assembly|interface issue|scm hyd mech components|locking mechanism|qa qs qi|goods receiving inspection error|Extension Rod P55-10|REVESTIMENTO
ZB|100020278|06/02/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm electrical|other pcbs|vendor|equipment malfunction|Communications failure Line A on SCM 25|Communications failure Line A on SCM 25
ZB|P6000105708|14/08/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|specification error|scm|scm|engineering|engineering error|Julia Claim 001 SRM Silicone bladders|Design of bladder volume incorrect
ZE|P6000088604|22/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|(CDM) Wheatstone SCM Communication error|unknown info root_cause
ZF|P7000024900|16/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm hyd mech components|outer can|vendor|final inspection error|Outer Can does not mount|101545 - KRISTIANSANDS SKRUEFABRIKK
ZF|P7000024900|10/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|CVHP 53 and CVHP 54 are crossed|unknown info root_cause
ZF|100052701|22/03/2010|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|other defect|functional|scm|scm|other causes damage|cause not found|SCM com.  problems Tyrihans A4 SEM B|unknown info root_cause
ZF|100018082|13/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|physical|electronic boards|other eletronic boards|materials stores|improper handling|Delivery of el-boards from 0300 KOS1|New prosess will be implemented 01.08.13
ZF|P6000080343|29/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|functional|electronic boards|main boards cpu & i o|projects|documentation error|Missing signal on Ch 19  index 35 in ETU|Wrong wiring spec
ZF|P6000068918|03/04/2012|priority 3 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (fluid)|scm hyd mech components|compensator|assy|operator error|Silicon leakage after hyperbaric test.|Bladder hose adapter not tighten
ZF|P6000069056|05/10/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Wiring on  EC 8:3 4 & 7 8 crossed Canbus|Human failure  wrong wiring (spec is OK)
ZF|P7000001843|22/05/2018|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO|test|leak|object types to eng matl class|scm|test|other specify in comments|MMR - Strainer Leakage|Unknown Cause
ZF|P6000068924|13/02/2012|priority 3 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO NOPT|design|specification error|computer system software|sem tpu config|engineering|engineering error|Errors in the new config|Corrected Config for SmartTool required
ZF|P6000058949|30/03/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|Update MF-0000020212|Update of important notice document
ZF|P6000058949|05/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO NOPT|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Incorrect screw quality used in BOM
ZF|P6000101955|06/07/2015|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|damage|damage due to handling|scm|scm|assy|operator error|SCMMMR Tyrihans 3 broken  Bracket bolts|operator applied too high torque
ZF|7104033|13/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|other defect|physical|scm|scm|other causes damage|cause not found|Raw oil and gas inside the SCM|Caused by leakage in blind plate.
ZF|100018082|18/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOPT ATCO NOTE|test|test omitted|scm|scm|other causes damage|cause not found|Åsg F&D 20 SCM overdue mobilizing time|SCM overdue mobilizing time
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|ATCO NOTE NOPT NOCO|design|material master error|scm|scm|vendor|material error|DCV/COV with Cobalt pilot ball|DCV/COV with Cobalt pilot ball
ZF|P6000088614|19/07/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|certification|information incorrect|scm|scm|assembly|other specify in comments|Traceability miss match  non complience|SN not consistency on all papers and SCM
ZE|100056261|12/03/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|sem|causes for improvement|process procedure not being followed|SEM Common Alarm|Cancelled - customer caused
ZF|P6000055605|28/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm hyd mech components|other mechanical components|fabrication shop personnel|operator error|Too long tubing|Tubes not made accoring to drawing
ZF|P7000039672|08/10/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|dbi error|hydraulic distribution|other hydraulic components|engineering|ecn change|ECN  6147855 - PN  P7000039672|ECN
ZF|P7000001621|28/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm|scm|other causes damage|cause not found|Furação sem rosca|faltou realizar uma rosca
ZF|100018531|05/10/2015|priority 1 |Q3|SHELL|unknown info region|NOTE NOCO ATCO|assembly|physical damage|scm hyd mech components|other mechanical components|fabrication shop equipment|gas issues|MMR - Leakage through Lock. Mech.|Fracture due to Hydrogen embrittlement
ZF|P6000028371|23/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|procedure error|topside products|other topside products|engineering|procedure error|ETU Software 6.2|ETU Software Error
ZF|7100320|16/02/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|assy|improper handling|MMR - Broken Screw in Manifold Block|unknown info root_cause
ZF|100035013|21/09/2010|priority 2 |Q3|SHELL|unknown info region|NOTE ATCO NOCO|design|material master error|electronic boards|main boards cpu & i o|engineering|continuous improvement|Upgrade cpu 201 HW and SW|CPU201 board has been upgraded
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|P6000043714|06/07/2011|priority 3 |Q3|PETROBRAS|GOM|ATCO NOCO NOPT NOTE|test|function|computer system software|sw|engineering|continuous improvement|Petrobras Cascade XT-SCM|Petrobras Cascade XT-SCM
ZF|P6000068924|29/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|component error|scm|scm|test|damaged during testing|Water inside module after hyperbaric|Water inside module after hyperbaric
ZF|100049000|07/07/2011|priority 1 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 17|Investigate Coupler Rotation-BPAT SCM 17
ZE|100035118|18/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM) Data conversion of SCM sensor|Data conversion of SCM sensor
ZF|P6000079984|21/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|machining|length depth error|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Possible failure of dim on m.blocks Dunf|Ref QN 200283096
ZF|100056918|28/08/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|component error|scm|scm|test|incorrect set up testing|(SS) Range setting incorrect for chart|Range setting incorrect for chart
ZF|P7000024900|14/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|physical damage|scm|scm|assy|improper handling|Base Plate danificada / Damaged|unknown info root_cause
ZF|P6000028371|01/04/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|change deviation request|process substitution request|scm|scm|other external causes|customer error responsibility|Shell reqested - process change|Shell reqested - process change
ZF|100030542|21/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|cleanliness|scm hyd mech components|other hydraulic components|test|improper handling|SCM Torqued down on TS w/Protection Caps|SCM Torqued down on TS w/Protection Caps
ZB|P6000043714|31/03/2009|priority 2 |Q1|PETROBRAS|GOM|NOPT ATCO NOCO NOTE|assembly|interface issue|scm hydraulic|other scm hydraulic|other causes damage|no noncompliance|SCM and torque tool interface conflict.|see longtext -torque tool  new or modify
ZF|7104033|19/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|test|operator error|Water inside SCM after hyperbarictest|Operator forgot to tighten test hose
ZF|100026328|21/09/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|component error|scm|scm|assy|damaged during assembly|Vazamento de silicone no SCM Viola SN 05|unknown info root_cause
ZF|P6000091085|04/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|function|scm|scm|other causes damage|no noncompliance|SEM B lost connection during EETEST|External failure  voltage drop in SPCTU
ZF|P6000079984|07/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|electronic boards|main boards cpu & i o|engineering|procedure error|Wrong SEM supply voltage reading at ST|Lack of calibr. procedure  ref NRB text
ZF|P6000069056|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|design|drawing error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Insufficient wall thickness in m. block|Ref. QN 200241870
ZF|P6000093498|07/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|other defect|part lost|instrumentation|scm pressure transmitter|test|missing parts|Missing o-ring on transmitter|O-Ring lost in FMC warehouse/workshop
ZF|P6000063531|23/01/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|test omitted|scm|scm|test|missing parts|SCM not mobilized acc. to FMC procedure|No test equipment available
ZF|P6000064910|04/08/2011|priority 2 |Q3|TOTAL|unknown info region|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|engineering|continuous improvement|Leakage on inner barriere system|Lakage in inner barrirer
ZF|P6000105542|10/12/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN17|Wrong welding pin defined for man. block
ZD|7104075|31/03/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|coating plating|incorrect colour coating|scm hyd mech components|sem can|vendor|coating defect|SEM Xylan Coating|unknown info root_cause
ZF|100056176|03/11/2009|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|test|unknown info damage_desc|scm|scm|test|unknown info cause_desc|Åsg F&D09 Mob not performed  on SCM|No time for a mobilization of  the SCM
ZF|100020562|27/08/2009|priority 2 |Q3|BP|GOM|NOTE NOPT ATCO NOCO|test|function|scm|scm|vendor|equipment malfunction|BPTH SCM 24 Nova DHI card issue|BPTH SCM 24 Nova DHI card issue
ZF|P7000001621|11/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|damage|damage from corrosion|scm|scm|other external causes|customer error responsibility|NUT DANIFICADA|Natural Corrosion of item
ZF|P6000116166|10/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (gas)|scm hyd mech components|hydraulic fittings|assy|operator error|Gas leakage in fitting|Incorrect assembly of fittings.
ZF|P7000000897|07/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic coupler|vendor|equipment malfunction|Leakage detected in LP supply coupler.|unknown info root_cause
ZF|P7000000897|26/09/2011|priority 1 |Q3|SHELL|unknown info region|ATCO NOTE NOPT NOCO|assembly|imension (tolerance)|scm hyd mech components|baseplate|vendor|specification not followed|Diâmetro incorreto.|USILIDER - BASE PLATE
ZE|P6000088751|21/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Update KS200e SW to 610.0|To Update KS200e SW to 610.0
ZF|P6000068902|26/09/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|instrumentation|scm flowmeter|machine shop equipment|machine malfunction|LP return flowmeter will not count|Machine Malfunction
ZF|P6000068912|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SEM failure detected in extend. test
ZF|P6000083428|13/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|vendor|clarification|Additional endurance test|Failure SEM Baseplate with penetrator
ZF|P6000068918|01/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No failure detected in extended testing
ZB|7104670|06/12/2008|priority 4 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|other defect|physical|scm|scm|other causes damage|damage from wear and tear|F&D Hydraulic leak on SCM base|Protection Caps still on couplers
ZF|P7000000897|15/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly|interface issue|scm hyd mech components|outer can|assy|damaged during assembly|Scratch on Outercan surface|unknown info root_cause
ZB|P6000077638|05/02/2015|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|dbi error|scm|scm|engineering|engineering error|SCM delivered with wrong type restrictor|Wrong flowrestrictor used in repeat SCM
ZF|P7000000897|25/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|cause not found|Return Flow meter not working|unknown info root_cause
ZF|P6000050867|19/07/2010|priority 1 |Q3|PETROBRAS|GOM|NOPT NOTE NOCO ATCO|other defect|functional|test and transportation|communication test unit (ctu)|intercompany|kongsberg|DAS loss of communication|DAS loss of communication
ZF|100009059|08/07/2010|priority 2 |Q3|EXXONMOBIL|GOM|NOPT NOTE NOCO ATCO|procurement|purchase order incorrect|t & rc hydraulic pneumatic eq.|hydraulic pneumatic unit|assy|missing operation|Part shipped without QA approval.|Part shipped without QA approval.
ZD|P6000062990|09/06/2015|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|documentation|incorrect certificates records|vendor quality system issue|quality management system|vendor|specification not followed|ATS - Wrong Revision|ECN
ZF|P6000084242|31/10/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|variance|enhance process|SEM A failure to communicate with SPCTU|Communication failed
ZF|P6000068924|08/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|assembled incorrectly|electric products|electrical wire|engineering|continuous improvement|Wrong use of miniseal|Instructions for use of miniseal
ZF|P6000064909|12/04/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|other defect|functional|scm|scm|other causes damage|planning error|Planning error in bid|Planning error in bid
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOTE NOPT NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #7 Wiring|BPTH SKOFLO SCM SN #7 Wiring
ZF|100048038|01/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|leakage (fluid)|hydraulic products|accumulator|vendor|equipment malfunction|Leakage on accumulator|Internal leakage in accumulator  see ZD
ZD|P6000067533|12/10/2011|priority 1 |Q2|KIRINSKOYE SPS|unknown info region|NOCO ATCO NOTE|damage|damage during testing|scm|scm|test|operator error|Kirinskoye SCM 04|SCM mounted to SCMTS w/HC protective cap
ZF|P6000122626|14/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|damage|damage during testing|scm|scm|test|damaged during testing|Too high pressure applied to HP supply|Failure on test equipment
ZF|100048038|25/01/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|NOPT NOCO ATCO NOTE|assembly test|assembled incorrectly|scm|scm|materials stores|operator error|Wrong P/N for hyd. valve on SCM|s/n 43899  assigned to incorrect p/n
ZF|P6000080733|09/04/2014|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|vendor|specification not followed|MMRSCM  Fram H Nord  SN 1  No Comm issue|Wrong marking on wiring from penetrator
ZF|P6000119335|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000001843|23/10/2015|priority 3 |Q3|PETROBRAS|unknown info region|NOTE NOCO ATCO|assembly|assembled incorrectly|electric products|electrical connector|assy|operator error|MMR - Wrong Assembly of Top Connectors|unknown info root_cause
ZF|P7000039672|20/12/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|electrical|functional|object types to eng matl class|scm|vendor|equipment malfunction|Falha de leitura PT|unknown info root_cause
ZF|100016711|04/03/2011|priority 3 |Q3|BP|GOM|NOTE ATCO NOCO|raw material|defects in material|scm|scm|vendor|operator error|Vendor soldering non-conformance|Vendor soldering non-conformance
ZF|P6000068924|12/06/2012|priority 1 |Q3|TOTAL|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm hyd mech components|hydraulic coupler|test|incorrect set up testing|Loose HCs in manifold block.|Followed up in QN 200296914
ZD|P6000104111|13/08/2014|priority 1 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|CERTS ISSUE|VL Specification not followed
ZF|100050519|10/10/2012|priority 2 |Q3|TOTAL|unknown info region|ATCO NOTE NOCO|test|function|scm|scm|vendor|clarification|MOHO 12 DHI card|Follow-up ref QN 200269268
ZD|P6000088751|15/01/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm|scm|test|operator error|GWF SCM#3 SEMA CPU IN SUSPEND MODE| SEM-A CPU IN SUSPEND MODE
ZF|100016711|05/08/2011|priority 2 |Q3|BP|GOM|NOTE NOCO ATCO|damage|damage from corrosion|scm|scm|other causes damage|damage from wear and tear|SCM 32 pitting on EC seal surfaces|SCM 32 pitting on EC seal surfaces
ZF|P6000074156|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|7102643|19/03/2010|priority 4 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|assembly|interface issue|scm|scm|test|incorrect set up testing|F&D 16 Not able to install SCM properly|Incorrect placement of poppets
ZF|P6000057007|28/10/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|procedure error|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|engineering|procedure error|RIT procedure issues|RIT procedure issues
ZF|100006609|06/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|test|damaged during testing|Falha de comunicacao SEM A|SEM A_Falha na comunicação
ZF|100020562|14/03/2009|priority 3 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|documentation|procedure process error|scm|scm|vendor|design error| BPTH|Prcocedural Error
ZF|P7000016420|07/12/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|test|incorrect set up testing|SRT SCM P-55 SN 11|lab test box com fio solto
ZF|3787102|07/05/2008|priority 2 |Q3|SNORRE|unknown info region|NOCO ATCO NOTE|machining|unknown info damage_desc|fks quality system issues|quality management system|assy|missing operation|Snorre WCM SN 08 overhaling SO-999480|unknown info root_cause
ZF|100030542|30/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|missed operation|scm|scm|test|missed operation|Cust Deviation to shipping procedure|Customer Request
ZF|7102643|06/01/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|assembly|interface issue|scm hyd mech components|hydraulic coupler|engineering|engineering error|Missing HC24 and HC25|Wrong configuration on SCMMB coupler
ZF|P7000016420|25/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|raw material|defects in material|electric products|electrical connector|materials stores|improper packaging & storage|Conector Eletrico - Outercan|unknown info root_cause
ZF|P6000141559|03/01/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|damaged during testing|scm|scm|test|specification not followed|Wrong oiltype used during flushing.|Used wrong hydraulic fluid
ZF|P6000088604|28/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|dwg error|Drawings|Drawing error
ZF|P6000064911|27/05/2011|priority 2 |Q3|TOTAL|unknown info region|NOTE NOPT NOCO ATCO|documentation|procedure process error|scm|scm|engineering|continuous improvement|mangler mini seal til trafo 3000volt|Additional parts added to BOM.
ZD|7104020|26/11/2013|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOTE NOCO|marking|incorrect size of marking|scm hyd mech components|outer can|vendor|coating defect|Outer can stripes|Coating Defect
ZF|P6000084906|18/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Wrong wiring EC8|Incorrect wiring by operator.
ZF|P6000065528|05/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|coating plating|coating not applied|electronic boards|power units|engineering|specification error|Inadequate Insulation of PSDM600|Spec. improved  design upgraded
ZF|P6000093498|13/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|engineering|engineering error|WOCM -Fail to connect BMU-2B to consumer|Software causing component failure
ZF|100041392|25/06/2008|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOCO NOPT|damage|damage during testing|scm|scm|assy|operator error|Fitting damaged during outercan assembly|unknown info root_cause
ZE|P6000063531|03/05/2017|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Power supply error (Vigdis)|unknown info root_cause
ZB|100020278|11/02/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|ATCO NOPT NOTE NOCO|assembly test|function|scm|scm|other causes damage|unknown info cause_desc|SCM 26 communication problem|unknown info root_cause
ZF|100049000|06/06/2011|priority 3 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|damage|damage during assembly|hydraulic products|coupler|assy|damaged during assembly|Replace HC 10 and HC 22|Replace HC10 & HC22
ZF|P6000093498|27/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|specification not followed|Leakeage result to high|Leakage of DCV
ZB|100017278|09/11/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|other defect|functional|scm|scm|qa qs qi|operator error|Accidentally pressured up TRSCSSV|Procedure not followed
ZD|P6000074156|16/07/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE|documentation|procedure process error|scm|scm|other causes damage|qn cancelled|HPDCV 54 failure|QN cancelled
ZF|P6000069820|15/03/2012|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|NOPT NOTE ATCO NOCO|other defect|physical|scm|scm|materials stores|improper handling|(SS) SCM drop during transfering|Improper handling
ZF|P7000008275|07/09/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|vendor|equipment malfunction|FALHA DE OPERAÇÃO DAS VÁLVULAS DO SCM|Acionamento de DCV inoperante
ZB|100020562|24/07/2008|priority 3 |Q1|BP|GOM|NOTE NOCO NOPT|test|function|scm electrical|other scm electrical|vendor|equipment malfunction|Communications issue on SCM 17|Communications issue on SCM 17
ZF|P6000126219|01/05/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|marking|marking content error|object types to eng matl class|scm|intercompany|kongsberg|SCM Dataplate Incorrect MAC Address|Name plate has incorrect MAC address
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|100001156|25/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|missed operation|test and transportation|other scm test & transport equipment|other causes damage|cause not found|Not able to perform Sand Sensor test.|CPI test equipment not available
ZF|P6000042308|11/12/2009|priority 3 |Q3|TULLOW|WEST AFRICA|NOTE NOPT NOCO ATCO|test|function|scm|scm|test|missed operation|Jubilee SCM procedure issues|Jubilee SCM procedure issues
ZF|P6000104112|05/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|interface issue|electric products|electrical connector|vendor|assembly error|Damage on electrical connectors|SCMTS SCMMB EC assembled w/o guidepin
ZF|P6000043122|12/10/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|electronic boards|other eletronic boards|vendor|material error|CIB600 board not working properly|Error to be confirmed in QN200144382
ZF|P7000016420|19/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|coating plating|incorrect colour coating|scm hyd mech components|locking mechanism|other causes damage|cause not found|Revestimento em desacordo com DBI.|unknown info root_cause
ZF|P6000079032|01/06/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO|test|function|electronic boards|main boards cpu & i o|other causes damage|cause not found|Communication error PSD|See folowup QN for conclusion.
ZF|P6000039844|27/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|engineering error|Lp adapterplate need adapter for tube.|Assembly not created according to master
ZF|P6000088626|18/05/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|drawing error|scm hyd mech components|outer can|engineering|dwg error|Torque tool (tt) interface on MCM and HC|Wrong tolerances on DWG for MCM & HC
ZE|P6000121393|18/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|damage during testing|scm|scm|causes for improvement|process procedure not being followed|Too high voltage vrong way|Operator error  wrong jumper used
ZF|100049000|16/05/2012|priority 2 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|test|wrong test procedure used|scm|scm|test|incorrect set up testing|SCM 24 Visual inspection / Seal inspect|SCM 24 Visual inspection / Seal Inspect
ZB|100035013|03/01/2010|priority 1 |Q1|SHELL|unknown info region|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|vendor|equipment malfunction|Communication with SEM-B has failed|Electronic board failure
ZF|100018082|22/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of CPI test equipment
ZF|P6000058949|01/02/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|damage|damage due to handling|electric products|electrical harness|assy|improper handling|Def. locking mechanism on CPU Rib.cables|Damaged when disconnecting Ribbon Cables
ZF|P6000074156|13/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100035013|21/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|cleanliness|scm hyd mech components|other mechanical components|other causes damage|cause not found|Contamination of MEG in hydraulic system|contamination of MEG in hydraulic system
ZF|P6000042969|13/03/2010|priority 1 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO NOPT|documentation|procedure process error|scm|scm|test|incorrect set up testing|RIBS application sent to TIF card|Incorrect documentation
ZF|P7000000897|14/09/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|other defect|functional|ss compl. & w.over xt general|tree assembly|other causes damage|no noncompliance|Caixa do Manifold Block aberta|NÃO HÁ NÃO CONFORMIDADE
ZF|P6000098616|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000121958|04/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|drawing error|scm hyd mech components|sem bracket|engineering|dwg error|Part does not fit|Wrong hole patterns in SEM bracket
ZF|100036232|09/11/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOPR ATCO|design|dbi error|fks quality system issues|engineering system|engineering|engineering error|Shell Pierce engineering not completed|unknown info root_cause
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZE|P6000122626|05/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|damage|damage during testing|scm|scm|variance|capture mistake|Too high pressure applied to HP supply|Action taken for prevent same in the fut
ZE|100046112|22/06/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|documentation requirement|error in document spec|(CDM) Angel  SCM  Update HFT|HFT procedure has been updated
ZB|100035013|15/04/2010|priority 2 |Q1|SHELL|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|assy|manufacturing engineer erorr|GC#003-SCM#20 Communication failure|Wrong cam card
ZF|P7000001621|27/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm|scm|test|damaged during testing|DCV's com vazamento|unknown info root_cause
ZF|100067526|12/05/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|test omitted|scm|scm|other external causes|customer error responsibility|CR:Hyperbaric pressure test notperformed|Hyperbaric test not included in PO
ZF|P7000039672|26/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|other defect|part lost|instrumentation|other mechanical components|assy|missing parts|Falta de materiais na montagem mecânica|131969 - PARKER HANNIFIN INDUSTRIA E
ZF|100018531|11/11/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|scm|scm|assy|operator error|QA não Convocada / QA not convened|Documentation process fault
ZF|7101463|16/08/2010|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|procedure error|scm|scm|engineering|procedure error|Megi SCM Test Procedure issues|Megi SCM Test Procedure issues
ZF|P7000024900|15/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|physical|scm|scm|other causes damage|no noncompliance|Concessão P600007731 -> 708-909-002|Concessão para substituição
ZB|P6000065886|24/04/2012|priority 1 |Q1|ENI|NORTH SEA|NOTE ATCO NOCO|test|function|scm|scm|vendor|equipment malfunction|SEM B no communication with Well N-2H|Faulty board
ZE|P6000043714|21/09/2009|priority 2 |Q3|PETROBRAS|GOM|NOCO NOPT NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|documentation|No standard for SCMMB drawing views|unknown info root_cause
ZF|P7000024191|16/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|missed operation|scm|scm|test|incorrect set up testing|SRT - GLOBAL #12 CAN BUS AND SERIAL LINE|Lab test box with problem.
ZF|100037966|08/10/2008|priority 3 |Q3|BP|unknown info region|ATCO NOCO NOTE NOPT|test|unknown info damage_desc|scm|scm|assy|lack of training|High pressure on return system|new technician
ZF|P7000039672|27/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|wrong part assembled|instrumentation|scm pressure transmitter|vendor|final inspection error|Wrong PN engraved / PT com PN errado|SCAN SENSE
ZD|P6000042308|20/07/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|documentation|incorrect certificates records|scm hyd mech components|locking mechanism|vendor|documentation|Incorrect coating spec. rivision|Incorrect coating spec. rivision
ZF|100056443|16/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|documentation|procedure process error|computer system software|basis e sw|engineering|procedure error|SW confusion during MMR activity|unknown info root_cause
ZE|7104033|09/09/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|damaged during testing|scm sem el opt component|other scm sem el opt components|marking|incorrect marking|Too high voltage used on SCM (388 VAC)|Name plate marked with too high voltage
ZF|P6000101955|19/03/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|leakage (fluid)|scm|scm|test|operator error|crack in the blader|Too high pressure during topping of SCM
ZF|P6000062990|11/08/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|documentation|missing certificates records|scm|scm|engineering|ecn error|SCM #1 Built to rev D|Wrong class used on ECN
ZF|P6000069056|10/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|component error|electric products|electrical components|assy|operator error|Short-circuit in wiring|Accidental opr err.  wiring now reworked
ZF|100015314|19/10/2010|priority 2 |Q3|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|unknown info region|ATCO NOPT NOCO NOTE|other defect|functional|scm|scm|projects|material error|Material not delivered to plant|Taken into Aberdeen under wrong Project
ZF|100052388|06/06/2012|priority 1 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|damage|wear & tear|scm|scm|other causes damage|damage from wear and tear|Short curcuit wiring to SEM A  no com.|Short curcuit wiring to SEM A  no com.
ZF|P6000029772|27/08/2009|priority 3 |Q3|ENGIE|NORTH SEA|NOTE ATCO NOCO NOPT|assembly|unknown info damage_desc|scm|scm mounting base (scm|vendor|unknown info cause_desc|Communication problems|Vendor recommended TRITON update
ZE|P6000103208|10/11/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|intercompany|houston|Damaged boards due wrong ext connection|Defective external wiring applied
ZF|100035013|10/08/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|function|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|ACM  need SEM reset after ACM powercycle|SEM reset after ACM powercycle
ZF|P7000039672|20/05/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|other defect|part lost|scm el opt components|el. connector|vendor|missing parts|FALTA DE ORING|1021 - Teledyne Oil and Gas
ZF|P6000104112|06/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|engineering|procedure error|SCM flow restriction outside criterita|Missing information in procedure
ZF|P6000058949|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Incorrect screw quality used in BOM
ZE|P6000125394|26/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|leakage (fluid)|scm hyd mech components|control valve|causes for improvement|process procedure ineffective|Internal leakage too high from DCV's|Vendor improved process
ZF|P6000068924|08/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|missed operation|scm|scm|assy|operator error|communication test of the M101|unknown info root_cause
ZB|7104670|09/04/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI OSTS NOPR|software|program configuration|object types to eng matl class|scm|software|other specify in comments|HEI OH054_ No DHgauge readings from SEMA|Unknown
ZF|100035118|03/09/2014|priority 2 |Q3|WOODSIDE|unknown info region|NOCO ATCO NOTE|test|leakage (fluid)|scm|scm|other causes damage|cause not found|Water in silicone sample after hyperbari|Reason for leakage not found.
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000063531|18/12/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|scm|scm|test|tooling|DHI 205 Test in HFT|Lack of functional CPI test equipment
ZF|P7000000897|18/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|other defect|functional|scm|scm|intercompany|kongsberg|RM 151 FAIL|unknown info root_cause
ZB|P6000063531|09/04/2017|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|software|functional|object types to eng matl class|scm|other causes damage|cause not found|Vigdis FD027 Sensor reading fault G1 SCM|unknown info root_cause
ZF|P7000008275|15/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|machining|inside diameter error|scm hyd mech components|outer can|other causes damage|cause not found|DIÂMETRO (SUCATA)|unknown info root_cause
ZB|P6000091085|21/10/2015|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|other defect|functional|electronic boards|other eletronic boards|intercompany|houston|OWIRS Accidental Disconnect Initiation|unknown info root_cause
ZE|7103234|05/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|missed operation|scm hyd mech components|accumulator|service :|improper job preparation|NCR 313417 SCM Accumulator no pre-charge|unknown info root_cause
ZF|100037427|03/03/2009|priority 3 |Q3|TOTAL|WEST AFRICA|NOTE NOPT ATCO NOCO|damage|damage during testing|scm|scm|test|operator error|Blinded smart return line|1st  occurance  no changes to procedure
ZF|100056443|22/07/2010|priority 1 |Q3|EDISON/EDF|NORTH SEA|NOTE NOPT ATCO NOCO|change deviation request|conversion approval|scm|scm|projects|customer error|SCM not mobilized according to PSM|SCM not mobilized according to PSM
ZF|P6000104116|09/07/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|machining|surface finish error|scm|scm|vendor|specification not followed|Damaged sealing surfaces|Damage on sealing surfaces
ZB|100052231|31/03/2009|priority 1 |Q1|CHEVRON|GOM|NOTE NOCO ATCO|test|function|software fks provided|sem|engineering|engineering error|SIO alarm causing a shutdown.|SIO alarm causing a shutdown.
ZF|P7000039672|20/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|misalignment interface error|scm hyd mech components|outer can|vendor|specification not followed|Top Plate não Monta na Outer Can|unknown info root_cause
ZF|P6000105542|30/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Too high internal leakage|Too high internal leakage on DCV
ZF|P6000074156|03/07/2017|priority 2 |Q3|SHELL|unknown info region|ATCO NOTE NOCO|test|damaged during testing|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|test|incorrect set up testing|Short circuit because of test equipment|mismatch between connector numbering
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZB|100057723|24/11/2008|priority 2 |Q1|LLOG|unknown info region|ATCO NOCO NOTE|other defect|physical|scm hydraulic|hydraulic control valves|other causes damage|damage from wear and tear|Failure to pass low pressure testing.|unknown info root_cause
ZB|100035400|12/02/2008|priority 2 |Q1|HESS|GOM|NOCO NOTE NOPT ATCO|assembly test|function|scm|sem|vendor|equipment malfunction|RAM Warning on SEM B|RAM Warning on SEM B
ZF|P6000138873|14/12/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|functional|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|other causes damage|no noncompliance|Wrong revision on penetrator|Old REV of SEM on Stock
ZF|100036232|05/05/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|test|operator error|Applied HP on LP during hyperbaric|Operator error  test set-up improved
ZE|100051992|04/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|Enfield - SCM Issue|SCM Issue
ZF|P6000058949|18/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|test and transportation|sensor simulator (sesi)|test|damaged during testing|E-probe simulator not working|E-probe simulator not working
ZF|P6000037215|08/12/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|other defect|functional|electric products|other electric products|engineering|engineering error|Gjøa - El. Actuators problem|FMC Engineering : Engineering Err
ZB|100001156|12/02/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE NOCO|test|leakage (fluid)|scm|scm|other causes damage|no noncompliance|Warranty claim 215|Reported leakage not found in inspection
ZF|100058509|20/07/2010|priority 2 |Q3|LLOG|GOM|ATCO NOCO NOTE NOPT|test|test omitted|scm|scm|qa qs qi|documentation error|Missing sign offs|unknown info root_cause
ZD|100052701|11/11/2009|priority 3 |Q2|STATOIL|NORTH SEA|NOPT NOCO ATCO NOTE|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Internal leakage in HP function valve|Damage on pilot seat sealing surface
ZF|P6000063632|08/11/2010|priority 2 |Q3|AQUILA PHASE 2|unknown info region|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Wrong presure test prosedure|Wrong test procedure linked to SCM
ZB|100001156|11/02/2010|priority 1 |Q1|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|test|leakage (fluid)|fks quality system issues|quality management system|vendor|coating defect|SCM Internal hydr. leak|unknown info root_cause
ZF|P6000105542|06/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Leakage test faild during FAT|Too high and unstable leakage from DCVs
ZD|100056261|11/04/2011|priority 3 |Q2|MURPHY|unknown info region|ATCO NOTE NOPT NOCO|documentation|procedure process error|scm|scm|engineering|procedure error|NONCONFORMANCE TO FUNCTIONALITY REQ|NONCONFORMANCE TO FUNCTIONALITY REQ
ZF|100050519|20/09/2011|priority 2 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|test|damaged during testing|Leakage from HP Supply to pilot|Leakage from HP Supply to pilot
ZF|P6000080343|11/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|poor wiring connection|Wiring error. Operator error
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #14 Wiring|BPTH SKOFLO SCM SN #14 Wiring
ZF|P6000116166|12/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|other causes damage|no noncompliance|Tullow Ten 10B Powerline fails (ESS:BI)|Bad wiring connection (corrected)
ZF|P6000088626|10/12/2014|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|engineering|engineering error|Missed BP Pre-production notification|Requirement in ITP not followed
ZF|P6000057855|11/02/2010|priority 3 |Q3|ENI|unknown info region|NOPT NOTE ATCO NOCO|test|function|electronic boards|other eletronic boards|test|damaged during testing|Communication failure SEM|Error to be confirmed in QN200153740
ZB|100050520|28/01/2010|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|specification error|ss compl. & w.over xt general|external tree cap|engineering|specification error|Fault on IRCD|IRCD's would not release
ZF|P6000105542|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000132097|06/02/2019|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|marking|marking content error|object types to eng matl class|scm|engineering|dbi error|DOCUMENTATION ISSUE|unknown info root_cause
ZF|P6000116166|12/04/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO OSTS NOPT DLFL|other defect|physical|electric products|electrical harness|other causes damage|planning error|Blank labels were installed on Elec. Cap|Customer requested change
ZF|100034440|19/08/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|documentation|procedure process error|scm|scm|intercompany|kongsberg|Procedure issue with ETU|Procedure issue with ETU
ZF|P6000104111|16/03/2016|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Voltage reading out of range|Voltage value to be reviewed
ZE|P6000102687|11/06/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|damage during assembly|scm|scm|causes for improvement|process procedure not being followed|WOCM installed with plastic protection|Operator error
ZF|P6000090632|23/06/2015|priority 2 |Q3|CHEVRON|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|test|operator error|Wheatstone WO03 SN2 - Water Ingress|Operator error  lack of knowledge
ZF|P1000018406|02/11/2011|priority 3 |Q3|BP|GOM|NOPT NOTE NOCO ATCO|design|dbi error|scmmb|mountingbase plate|engineering|dbi error|Incorrect bolts|Incorrect bolts
ZF|P7000001843|02/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|damage|damage during transport|scm|scm|other causes damage|damage from wear and tear|AMASSAMENTO NA OUTERCAN|Equipamento retornou do campo
ZF|100049000|20/12/2008|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|change deviation request|part substitution request|ss compl. & w.over xt general|tree assembly|other causes damage|no noncompliance|Material substitution|unknown info root_cause
ZB|P6000062454|07/04/2011|priority 1 |Q1|DAEWOO|unknown info region|NOPT ATCO NOTE NOCO|other defect|physical|scm hyd mech components|control valve|intercompany|kongsberg|(SS): HHI SCM #1 Leaking COVLP|Request by FKS
ZE|P6000074156|28/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM)Prellude - to blank out the ESRS|Prellude - to blank out the ESRS
ZF|P6000109194|09/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (gas)|scm|scm|assy|operator error|Internal nitrogen leakage on SCM|Collar not ajusted correctly
ZB|100056443|25/07/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|documentation requirement|procedure process error|scm|scm|other causes damage|planning error|Manifold Ethernet jumper interupting com|manifold eternet jumper interupting coms
ZF|P7000016420|05/11/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm|scm|vendor|final inspection error|CHANGE-OVER NÃO CONFORME|Rotator
ZB|100020278|29/10/2009|priority 2 |Q1|EXXONMOBIL|unknown info region|NOCO NOTE ATCO|test|function|scm|scm|other causes damage|cause not found|06-MEGI-037 PT1 won't read while on HMI|Cause not Found- W Ind to investigate
ZD|100049000|04/11/2010|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|documentation|missing certificates records|vendor quality system issue|quality management system|vendor|specification not followed|Missing Required Docs per DBI-ATS Submit|Missing Requied Docs per DBI
ZF|P6000100953|03/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|documentation|procedure process error|scm hyd mech components|outer can|engineering|dwg error| marking conflict on drawings|Marking conflict on drawings
ZF|100001156|26/02/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|test omitted|scm|scm|other external causes|customer error responsibility|Reduction in mobilization scope|Too short notice by customer
ZF|100037428|06/04/2008|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE|other defect|functional|scm|scm|engineering|engineering error|R303 and R305 PWV shutdown|unknown info root_cause
ZF|7104033|21/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|missing certificates records|scm|scm|other causes damage|cause not found|Lack of documentation|Unkown
ZF|P7000039672|10/11/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|component error|electronic boards|other eletronic boards|intercompany|kongsberg|Não é possivel obter boot do MRM82A|unknown info root_cause
ZD|100017997|10/12/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|vendor|equipment malfunction|No Communication to Conmpass Sensor|No Communication to Conmpass Sensor
ZB|P6000058949|07/04/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|other defect|physical|scm hyd mech components|hydraulic tubing|other external causes|customer error responsibility|GF - SCM - Hydraulic Leakage|Customer Error/responsibility
ZF|100049000|21/04/2008|priority 3 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|documentation|procedure process error|scm|scm|assy|operator error|PRD-0000020064 not performed|missed procedure step
ZF|P6000121268|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|marking|marking content error|scm hyd mech components|control valve|materials stores|operator error|Missmatch S/N label/Part|Part labeled with wrong S/N in stock
ZF|P7000016420|28/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|imension (tolerance)|scm hyd mech components|baseplate|vendor|specification not followed|Base Plate não conforme|USILIDER - BASE PLATE
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|NOTE NOPT ATCO NOCO|design|material master error|scm|scm|vendor|material error|DCV/COV with Cobalt pilot ball|DCV/COV with Cobalt pilot ball
ZB|100017278|01/09/2008|priority 2 |Q1|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|test|leakage (fluid)|scm|hydraulic valves|other causes damage|unknown info cause_desc|HP Line in SCM leaking!|unknown info root_cause
ZD|P6000083428|14/10/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|incorrect certificates records|test and transportation|scm lifting tool|intercompany|kongsberg|Part/Cert Issue|unknown info root_cause
ZB|P7000002082|02/05/2017|priority 2 |Q1|PETROBRAS|unknown info region|ATCO NOTI NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|PRA-1 - Fechamento do módulo de P-55|unknown info root_cause
ZB|100035014|09/10/2008|priority 3 |Q1|STATOIL|unknown info region|ATCO NOCO NOTE NOPT|damage|unknown info damage_desc|electronic boards|other eletronic boards|other causes damage|cause not found|SEM-A has I/O-card problems|I/O card possibly defect
ZB|100048038|06/01/2010|priority 2 |Q1|CHEVRON|WEST AFRICA|ATCO NOTE NOCO|other defect|functional|scm electrical|other scm electrical|vendor|equipment malfunction|Communication Failure with SEM B|Communication Failure with SEM B
ZF|P7000016420|30/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|imension (tolerance)|scm|scm|vendor|design error|Protection Ring não monta|unknown info root_cause
ZF|P6000028371|20/01/2009|priority 3 |Q3|SHELL|GOM|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|test|tooling|Water in SCM after Hyperbaric Test|worn test equipment
ZF|7104075|07/05/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|design|procedure error|scm|scm|engineering|procedure error|Internal PT Acc Criteria in HFT Prd.|Internal PT Acc Criteria in HFT Prd.
ZF|P6000121268|02/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wrong position assembled on PTs|Position and wiring error
ZF|P7000016420|05/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|change deviation request|function|electronic boards|other eletronic boards|intercompany|kongsberg|CPU com desvios|ECN Class 1
ZE|100020562|12/08/2009|priority 1 |Q3|BP|GOM|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|sem|causes for improvement|documentation|CAR 1 RCA Actions_2 from RPT10033107|Implement RCA RPT10033107 Recommendation
ZB|100050519|15/10/2009|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|assy|manufacturing engineer erorr|Silicon Leak and Burst Bladder in SCM|Silican leak and burst bladder
ZF|P6000121393|18/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Hydraulic fluid inside the SCM|External leakage on COV.
ZB|100050519|04/09/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|damage|damage during transport|scm|scm|other external causes|customer error responsibility|SCM was delivered with damaged outercan.|unknown info root_cause
ZD|P6000028371|05/01/2015|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|coating plating|coating defect|scm hyd mech components|outer can|vendor|operator error|Bead blast name plate|unknown info root_cause
ZF|P7000039672|08/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|test omitted|scm|scm|test|operator error|Ausência dos Printouts|unknown info root_cause
ZE|P6000088604|20/06/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|assembly|other specify in comments|Wheatstone  SCM  Clash issue|Dimension (max & min height) varies
ZB|7102969|15/02/2010|priority 3 |Q1|MOBIL EG|unknown info region|ATCO NOCO NOPT NOTE|damage|damage during testing|customer compliant|noncompliance to customer requirement|test|damaged during testing|Filter Board Burn Damage|Filter Board Burn Damage
ZF|P6000098616|27/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|specification error|HS CAN bus grounding error on CPU card|ISO GND missed in wiring specification
ZF|P1000018406|14/03/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|interface issue|scm|scm|assy|operator error|Tubing Touching Other Surfaces|Tubing Touching Other Surfaces
ZF|100037967|10/04/2008|priority 2 |Q3|BP|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm|scm|assy|unknown info cause_desc|FPSO NCR 029 - SCM P09 SEM Addresses|unknown info root_cause
ZF|P6000069056|01/02/2012|priority 1 |Q3|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|test|function|scm|scm|engineering|continuous improvement|Earth fault on P6000062266 LNCS602|Improved earth strap assembly
ZF|P6000122626|10/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|wrong lenght|Tubes dimension did not fit for SCM615
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|raw material|incorrect material|scm|scm mounting base (scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000122626|11/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|specification error|electronic boards|other eletronic boards|vendor|design error|Error in el design|Wrong rev. 17 ea updated to rev B
ZF|100058509|27/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|other defect|functional|topside products|n a sw|intercompany|kongsberg|LLOG GC448 fast scan issue|MCS receives rubbish fastscan data from
ZF|P7000024900|03/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|interface issue|scm hyd mech components|baseplate|other causes damage|cause not found|Não Conformidade na Base Plate.|unknown info root_cause
ZF|P7000001843|03/01/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|missed operation|scm|scm|other causes damage|planning error|Problemas com o simulador PDG.|unknown info root_cause
ZB|100017997|05/05/2010|priority 1 |Q1|BP|unknown info region|ATCO NOCO NOPT NOTE|damage|damage from corrosion|scm|scm|other causes damage|damage from wear and tear|BPTH IWOCS 4 earth strap corrosion|BPTH IWOCS 4 earth strap corrosion
ZF|P6000037365|06/04/2009|priority 3 |Q3|PETROBRAS|GOM|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|scm|scm|engineering|specification error|Wrong configuration of manifold block|Incorrect requirments in QN 200121418
ZF|P6000102687|22/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|leakage (gas)|scm|scm|vendor|equipment malfunction|Possible gas leakage inside SCM|Possible gas leakage in filling valve
ZF|P6000062990|15/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|leakage (fluid)|scm|scm|assy|operator error|Water contamination found in SCM silicon|Hose clamp not tigthen
ZD|P6000055605|14/03/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm sem el opt component|sem cable & wiring|vendor|assembly error|PT/TT Spare 7 not functioning on SCM 314|unknown info root_cause
ZF|P6000029747|17/09/2010|priority 1 |Q3|ENGIE|NORTH SEA|NOTE NOCO ATCO NOPT|documentation|procedure process error|scm|scm|engineering|continuous improvement|Operational problems regarding SW|In-house PRD updated with SIL SW info
ZB|100051269|09/05/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|electrical|component failure|scm|scm|other external causes|customer error responsibility|Vigdis  Failure internally in SCM|Mismatch between Y2 and TFMC SAP
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|NOCO NOTE ATCO NOPT|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 19|Investigate Coupler Rotation-BPAT SCM 19
ZB|P6000063531|29/04/2017|priority 1 |Q1|unknown info customer_name|unknown info region|OSTS NOPR NOTI|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Vigdis FD027 Sensor reading fault F1 SCM|unknown info root_cause
ZF|P6000068912|02/02/2012|priority 3 |Q3|TOTAL|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|assy|operator error|Fiber outside acceptance criteria|Fiber damaged during OC assembly
ZB|P6000101955|11/09/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|other defect|functional|scm|scm|vendor|equipment malfunction|Tyrihans Claim 265 SCM 03|Change over valve leaking
ZF|100049000|15/07/2011|priority 1 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 26|Investigate Coupler Rotation-BPAT SCM 26
ZF|100035118|15/05/2008|priority 2 |Q3|PETRONAS|unknown info region|ATCO NOTE NOPT NOCO|other defect|unknown info damage_desc|fks quality system issues|product realization|other external causes|unknown info cause_desc|WOCM Shipped in Horizontal (Side)|mis-interpretation
ZF|100049000|04/05/2010|priority 3 |Q3|BP|GOM|ATCO NOCO NOPT NOTE|test|leakage (fluid)|hydraulic couplers|hydraulic coupler|test|damaged during testing|Leaking Coupler|Leaking Coupler
ZF|P6000103208|12/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm|scm|test|damaged during testing|Test Error/Exxon/SCM/Exposed to Short|Test Error
ZF|100049000|21/06/2011|priority 1 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 28|Investigate Coupler Rotation -BPAT SCM28
ZF|100020278|15/05/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|drawing error|test and transportation|scm transport skid|engineering|continuous improvement|SCM improperly mounted to shipping skid|DWG updated ref CM500000315835
ZE|P6000105708|19/03/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm el opt components|scm wiring|causes for improvement|process procedure not being followed|No reading on EC3 pin 9 and 10|Procedure (unclear) not followed
ZF|P6000083428|24/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT shows higher reading during FAT|PT value increase during test
ZF|P6000088626|06/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|specification error|scm|scm|engineering|engineering error|Mac Address plate wrong|Nameplate copied from prev proj
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 05|Software improvement/correction
ZB|100067526|20/12/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPR OSTS|test|leak|scm|scm|test|improper set up|Unable to get good pressure test of DHSV|Test criteria was out of range for the s
ZF|P7000039672|14/02/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Trafo sem marcação de alinhamento|FMC KONGSBERG SUBSEA AS
ZD|P6000074156|13/03/2012|priority 3 |Q2|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|documentation|missing certificates records|vendor quality system issue|quality management system|vendor|specification not followed|ATS-Missing Documentation|DRL-0000020085  DRL-0000020034
ZF|P6000074156|06/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|marking|marking content error|scm|scm|vendor|specification not followed| Data plate information is incorrect.|data plate information is incorrect
ZF|100017278|13/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|drawing error|scm|scm|engineering|dwg error|Wrong path for alt.program SEM in doc.|Wrong path for alt.program SEM in doc.
ZF|P6000039844|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000068902|15/08/2011|priority 3 |Q3|TOTAL|unknown info region|NOTE NOCO ATCO NOPT|test|function|electronic boards|dhi|test|incorrect set up testing|DHI values are unstable|Simulator properties not adequate
ZF|P6000028371|05/06/2008|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|procurement|vendor did not complete required work|scm|scm|vendor|assembly error|Unlock Line Needs to be Moved|Lock/Unlock Line Not in Correct Position
ZF|P6000055605|27/12/2010|priority 2 |Q3|SHELL|GOM|NOTE NOCO ATCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZE|P7000039672|28/11/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|unknown info damage_group_desc|unknown info damage_desc|scm electrical|hydraulic flow meters|test|improper set up|FNCR-2365-Leitura Flow Meter Retorno|Setup de teste
ZF|100052701|09/07/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|documentation|incorrect user documentation (customer)|computer system software|network config|engineering|engineering error|SCM Tyrihans wrong SW versin delivered|Procedures were missing information
ZE|100048038|20/10/2016|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|variance|enhance process|Repeating SCM compensator issues|unknown info root_cause
ZF|P7000016420|22/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|sujeira no Manifold Block|Bosch - manifold block
ZF|100056176|12/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|scm|scm|test|tooling|V-CON Flowmeter test not performed|Lack of CPI test Equipment
ZF|P6000104114|24/05/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leak|scm|scm|machine shop equipment|machine malfunction|Leakage on SRM with SN 10|Leakage on SRM with SN 10
ZF|P6000103208|14/11/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|cleanliness|scm|scm|other causes damage|cause not found|Piece of metal inside coupler|Particle contamination found during test
ZF|P6000069820|10/01/2012|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|NOTE ATCO NOCO|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Version update
ZF|P6000088604|25/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|short circuits EC8:1 til EC9:1 and|Wiring error by operator.
ZF|P6000100953|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000067527|05/01/2012|priority 2 |Q3|BP|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Bug Fix
ZF|P6000147469|29/09/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|undertorqued|scm|scm|assy|operator error|Loose bolt found during Ph.C inspection|Operator forgot to torque bolts
ZF|P7000039672|05/09/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|design|dbi error|object types to eng matl class|kits|engineering|ecn change|ECN  7090703    PN  P7000017838|Error-concept/calculation
ZF|7105128|27/10/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|damage|wear & tear|scm hyd mech components|other mechanical components|qa qs qi|documentation error|No spare bolts f/the top lid of the SCM|unknown info root_cause
ZF|P6000104114|02/02/2018|priority 3 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE|damage|damage during testing|object types to eng matl class|srm_assy|vendor|specification not followed|Broken connector pins|unknown info root_cause
ZB|100020562|15/06/2009|priority 2 |Q1|BP|GOM|NOPT ATCO NOTE NOCO|test|function|scm electrical|other scm electrical|other causes damage|no noncompliance|No readings for sensor sim on EC4(9:12)|No readings for sensor sim on EC4(9:12)
ZF|P6000067533|08/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|materials stores|improper packaging & storage|SCM Modules stored outside with no PSM|Improper Storage
ZF|P6000088604|26/03/2015|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|wrong test procedure used|scm|scm|engineering|continuous improvement|(CDM)WST SCM #16-MRM Version discrepancy|MRM Version discrepancy
ZE|P6000088751|07/07/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm|scm|test|operator error|GWF SCM#3 SEM A CPU IN SUSPEND MODE| SEM - A CPU IN SUSPEND MODE.
ZF|100055600|18/04/2008|priority 3 |Q3|TALOS|GOM|NOPT ATCO NOCO NOTE|test|unknown info damage_desc|scm|scm|test|incorrect set up testing|damaged check valve on the HP return|damaged check valve on test hose
ZB|100056443|02/02/2015|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|engineering|procedure error|GC 274 ppp link on RIBT/RIBS (Vega)|unknown info root_cause
ZF|P6000055605|10/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|physical damage|scm|scm|assy|operator error|Break bolt flange|Screw fracture inside adapter plate hole
ZF|100020278|11/12/2009|priority 3 |Q3|EXXONMOBIL|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm|scm|engineering|procedure error|Megi Sea RIT procedure issues|Megi Sea RIT procedure issues
ZF|3794920|22/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|obsolescence issue:&|not available|scm hyd mech components|other mechanical components|other causes damage|cause not found|Missing GA DWG and spare part info.|Old parts not acc to today standard
ZE|P7000039672|10/08/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS OSNO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|electrical|other specify in comments|SCM - Leitura dos sensores externos|Problema de leitura
ZF|P7000024191|15/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|component error|scm sem el opt component|other scm sem el opt components|intercompany|kongsberg|Communication Failure SEM B|unknown info root_cause
ZE|100017997|23/08/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|qa qs qi|operator error|SCM EC port corrosion|unknown info root_cause
ZF|3811810|24/02/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|obsolescence issue:&|not available|scm|scm|engineering|continuous improvement|Incomplete BOM for PN 3811810|Not transferred from Procim/Update SAP
ZF|100026328|16/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|assy|manufacturing engineer erorr|Loosen cabels inside the SEM|Loose cables are fixed  supplier informe
ZB|P6000105542|12/08/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|damage|damage during assembly|scm|scm|fabrication shop personnel|operator error|OSD2 Claim 001 SCM Router cards|Wrong connector installed on XT
ZF|P6000037215|13/04/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE|test|function|electric products|other electric products|vendor|programmer error|Alt prog not downloading correctly|SW bug
ZF|P6000069056|08/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100017997|15/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|documentation|procedure process error|scm hyd mech components|outer can|vendor|specification not followed|BOM is incorrect|Specification not followed
ZF|P7000001843|04/09/2015|priority 2 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|assembly|assembled incorrectly|scm hyd mech components|other hydraulic components|assy|damaged during assembly|MMR - SCM does not reach vacuum|unknown info root_cause
ZF|P6000123495|18/02/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|High internal leakage - control valves|Too high leakage  all DCVs replaced.
ZB|100025661|12/06/2009|priority 2 |Q1|BP|GOM|ATCO NOCO NOTE NOPT|test|function|scm electrical|processor pcbs|vendor|equipment malfunction|F5 SCM 68 RAM Warning|F5 SCM 68 RAM Warning
ZF|100056918|06/03/2008|priority 2 |Q3|WOODSIDE|unknown info region|NOTE NOCO NOPT ATCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000073613|25/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|specification error|scm|scm|engineering|specification error|IWCM send/recieve test error|Wiring specification updated
ZF|P6000098616|20/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|continuous improvement|HS CAN bus grounding error on CPU card|ISO GND missed in wiring specification
ZF|P6000088604|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000058949|23/02/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Wrong wiring on outercan|Wiring towards Outercan incorrect
ZF|P6000031350|15/06/2009|priority 3 |Q3|GJØA|unknown info region|NOPT NOTE NOCO ATCO|test|function|electronic boards|dhi|vendor|unknown info cause_desc|Communication problems|Error to be confirmed in QN200132018
ZF|100037965|21/01/2009|priority 1 |Q3|BP|unknown info region|NOCO NOTE|other defect|functional|scm|scm|other causes damage|cause not found|BPLOF: HC7 (CV-O) failled to operate|unknown info root_cause
ZB|P6000064909|21/10/2014|priority 2 |Q1|TOTAL|unknown info region|NOCO ATCO NOTE|other defect|functional|scm sem el opt component|other scm sem el opt components|vendor|material error|Laggan Claim 089 - SCM#4|Component failure
ZF|P6000104115|15/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|design|drawing error|scm hyd mech components|baseplate|engineering|engineering error|Error on baseplate on teststand|Interface not verified towards SCM
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|ATCO NOCO NOTE NOPT|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|P6000050867|06/01/2010|priority 3 |Q3|PETROBRAS|unknown info region|NOTE NOPT ATCO NOCO|test|component error|electric products|electrical components|test|missed operation|DAS unit communication failure|DAS unit communication failure
ZD|P6000104116|02/08/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|machining|inside diameter error|ss compl. & w.over xt general|tree frame|other causes damage|qn cancelled|DIU LOCK PIN MISALIGNMENT|Dimensional Issue
ZF|P6000083428|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100005667|19/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|wear & tear|instrumentation|other scm instruments|test|missed operation|FSM Test in FAT not performed|Test equipment unstable
ZE|100051992|17/06/2015|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|intercompany|kongsberg|(CDM)Leakage from silicone check valve|Leakage from silicone check valve
ZF|P6000043766|14/04/2010|priority 4 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|test|damaged during testing|Nitrogen pre charge|Nitrogen pre charge
ZF|P6000138867|11/10/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|electronic boards|comm.link (power line)|test|tooling|Loss of communication powerline|Issues with SPCTU
ZE|P6000051036|03/08/2009|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|sem|causes for improvement|process procedure ineffective|QA in Material Control process|Process/Procedure Ineffective
ZF|P7000016420|23/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|other defect|physical|scm el opt components|el. connector|other causes damage|damage during transport|Fios de conectores danificados|Conector outer can Danificado
ZF|100049000|20/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm hyd mech components|control valve|other causes damage|cause not found|BP Atlantis SCM 32 leakage testing:|Leakage not identified  accepted as is
ZF|100054943|24/10/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|documentation|incorrect certificates records|scm|scm|other causes damage|qn cancelled|Acceptance criteria not clearly stated|Acceptance criteria in procedure are ok.
ZF|P7000024900|28/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|component error|scm hyd mech components|control valve|test|operator error|DCV danificada/manifold block danificado|Danificado durante desmontagemDanificado durante desmontagem
ZF|P6000079433|08/03/2012|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOPT NOTE NOCO|test|wrong test procedure used|computer system software|basis e sw|engineering|procedure error|SCM#3 SW download problems|SCM#3 SW download problems.
ZF|P6000076121|06/09/2011|priority 3 |Q3|CNOOC|unknown info region|ATCO NOPT NOCO NOTE|design|drawing error|scm hyd mech components|baseplate|engineering|dwg error|Outercan do not fit to the SCM|FMC DWG not updated
ZF|P7000024191|26/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|scm sem el opt component|other scm sem el opt components|engineering|continuous improvement|Frequencia da SEM B fora do especificado|unknown info root_cause
ZF|100020562|28/01/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|raw material|incorrect material|scm|scm|intercompany|kongsberg|BPTH ETU Projspec.dll for SKOFLO Changes|BPTH ETU Projspec.dll for SKOFLO Changes
ZF|100066325|06/08/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|assembly|component traceabilitynot maintained|scm|scm|materials stores|operator error|Duplicate serial numbers created.|Duplicat of excisting S/N in SAP
ZF|P6000088751|12/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Water inside SCM|Leakage on SCM outercan
ZB|P6000067533|08/10/2014|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|specification error|scm|scm|engineering|engineering error|Kirinskoye SCM 03 & 05 SUBSEA|Hydraulic couples on base need change
ZB|100020562|20/03/2009|priority 3 |Q1|BP|GOM|NOPT NOTE NOCO ATCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|Traceability Info Missing on BPTH SCM22|Traceability Info Missing on BPTH SCM22
ZF|P7000000897|10/01/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|coating plating|painting defect|scm|scm|paintshop|paint defect|Camada de revestimento - Coating layer|unknown info root_cause
ZE|P6000132097|05/11/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|documentation requirement|other specify in comments|Lack of Silicon on SCM|Customer choose not to mobilize EQ
ZF|P6000105542|08/01/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|change deviation request|conversion approval|scm|scm|other causes damage|cause not found|Deviation to TR1233  section  7.4.4|unknown info root_cause
ZF|P6000028371|23/10/2008|priority 1 |Q3|SHELL|GOM|NOTE NOPT NOCO ATCO|assembly|wrong part assembled|scm|scm|machine shop personnel|lack of training|Manifoldblock missing in iBASElist|error during transition from hand ibase
ZF|100029062|07/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|other causes damage|no noncompliance|THI not identified|Document is already linked in SAP
ZF|P7000001621|23/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm hyd mech components|baseplate|vendor|operator error|USINAGEM INCOMPLETA|erro na usinagem FMC
ZF|P6000126219|10/01/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|software|other specify in comments|object types to eng matl class|scm|software|other specify in comments|Appo SCM incorrect SW version on DHI203|TFMC Technician error
ZF|P7000039672|30/09/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|assy|damaged during assembly|Adapter plate HP danificada|unknown info root_cause
ZF|P7000000897|01/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|documentation|incorrect certificates records|scm|scm|engineering|continuous improvement|Ausencia de END no item|DOG without NDE
ZF|100035013|07/07/2009|priority 2 |Q3|SHELL|unknown info region|NOTE ATCO NOCO NOPT|assembly|unknown info damage_desc|scm|scm|test|unknown info cause_desc|Leakage on SCM|Leakage
ZF|P7000008275|01/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm sem el opt component|sem mech. components|intercompany|kongsberg|Seguimentos da eletrônica TUM (tambaú#4)|unknown info root_cause
ZF|7101401|23/02/2017|priority 3 |Q3|PETROBRAS|unknown info region|NOTE ATCO NOPT NOCO|assembly|physical damage|scm hyd mech components|hydraulic fittings|paintshop|operator error|MMR - Damaged Stabs from Outer Can|Error when placing Outer Can on pallet
ZF|P6000064910|26/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|dbi error|Product improvment|Incorrect part in BOM/DBI
ZE|P6000122626|09/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|test|component malfunction|Leakage test failed during FAT|unknown info root_cause
ZF|P7000000897|10/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|function|test and transportation|other scm test & transport equipment|other external causes|customer error responsibility|Used diferent ESPI Simulator|unknown info root_cause
ZF|P6000079984|20/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|assembled incorrectly|scm hyd mech components|other mechanical components|assy|operator error|Strainer not isolated.|GND strap in contact w/isolated strainer
ZF|P7000016420|25/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|electronic boards|other eletronic boards|other external causes|customer error responsibility|Corr monitor|Simulador CM não funciona
ZF|P7000016420|21/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|imension (tolerance)|scm|scm|other causes damage|cause not found|Nut com interferência no canal do Dog.|unknown info root_cause
ZF|100068622|13/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|service :|improper job preparation|CPU 151 RAM not upgraded|No final inspection performed
ZF|100018082|17/08/2012|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|assembly|assembled incorrectly|scm hyd mech components|baseplate|qa qs qi|operator error|SCM03 Mikkel  damaged o-ring|Loose bolts between M.block & Baseplate
ZB|3801623|21/03/2013|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT NOTE|assembly|interface issue|scm|scm|service :|damaged during installation|Wrong instalation of SCM on Heidrun well|unknown info root_cause
ZF|P6000055605|11/04/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|documentation|procedure process error|fks quality system issues|quality management system|engineering|procedure error|Miscopy in Doc No: TST60053923  MAC addr|Human mistake when writing TST60053923
ZF|P6000122626|05/04/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|leakage (fluid)|scm hyd mech components|control valve|engineering|engineering error|Leakage test failed during FAT|Returned to vendor for RCA
ZF|7104033|18/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZE|P6000105542|22/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN 16|See attached RCA
ZF|P6000058949|12/08/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Wrong placement and marking of EC's|DWG not checked or misread
ZF|P6000108025|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000105542|27/11/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|vendor|material error|RV leaking on top of SCM|SCM LEAKING RTV
ZF|100052701|16/04/2009|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm|scm|other causes damage|no noncompliance|CANbus testing failed|Error in external cables
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|ECN 7058839 - P7000017839
ZF|P7000000897|04/06/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|function|electric products|electrical harness|vendor|equipment malfunction|PT-09 fail readings at BC-10 SCM 10.|Sensor apresentando leituras flutuantes
ZF|P6000105542|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000074156|17/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|leakage (fluid)|scm|scm|test|damaged during testing|(CDM) Found silicone leak out from SCM|Silicone leak out from SC
ZD|P6000079984|13/09/2012|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage during testing|scm test stand|other mechanical components|test|damaged during testing|Marks on baseplate mounted ECs|Wrong angle on connector wing on SCMTS
ZF|100055762|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000037365|29/04/2009|priority 3 |Q3|PETROBRAS|GOM|NOTE NOPT NOCO ATCO|test|function|scm|scm|test|incorrect set up testing|Communication problems in hyperbaric|USB to RS232 conv between Laptop&ETU-PC
ZF|P6000121958|16/04/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm hyd mech components|control valve|other causes damage|no noncompliance|Insufficient capabilitites for SCM DCV's|DCV was qualified for the project y.2000
ZF|P6000064911|12/09/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|project|project requested unfinished shipment|object types to eng matl class|scm|other causes damage|planning error|Cust. Con. - Shipping with open S3's|unknown info root_cause
ZE|P6000091085|12/10/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|documentation|(N) - OWIRS Deadman sequence|unknown info root_cause
ZF|P7000016420|25/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|damage|damage during transport|scm|scm|other causes damage|damage from wear and tear|Peça danificada|unknown info root_cause
ZF|P6000069056|11/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|test|incorrect set up testing|Missing HC61 on hyberbaric camber 3|Hyp. chamber missing return line HC61
ZF|P6000079433|09/11/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOCO ATCO NOTE NOPT|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips inside the HP-Config Plug|Plugs not cleaned by supplier.
ZF|P6000104115|04/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|interface issue|scm el opt components|other el opt components|engineering|engineering error|Attenuiation in fiberpenetrator|Improper fiber splice bracket/box design
ZF|P6000064909|01/06/2011|priority 3 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|electric products|electrical harness|engineering|specification error|Wiring error in SEM|Delayed procedure & spec. update
ZF|100034629|16/10/2014|priority 1 |Q3|OVERALL PROJECT ROLL-UP OSEB.VESTFLANKEN|unknown info region|NOCO ATCO NOTE|test|leakage (fluid)|scm sem el opt component|optical penetrator (insert)|vendor|design error|Oseberg 23 silicone in SEM A|Seacon optical penetrator issue
ZF|P6000065886|16/12/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|design|drawing error|scm hyd mech components|accumulator|engineering|dwg error|Varous issues BOM and DWG|Various BOM and DWG incorrect
ZF|7101172|24/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|other defect|physical|scm|scm|other causes damage|cause not found|Crude oil and gas inside the SCM|Cause for leakage not found yet
ZF|P6000068918|05/07/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|assy|operator error|Wiring fault at PT1 A and B|Human opr failure at SCM wiring
ZB|100033987|12/11/2008|priority 1 |Q1|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|test|function|scm|scm|materials stores|operator error|WARRANTY CLAIM 170 Same as QN 200091091|unknown info root_cause
ZF|P6000116166|02/06/2016|priority 4 |Q3|TULLOW|WEST AFRICA|NOCO DLFL|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|LP DCVs Leak Test Failure|unknown info root_cause
ZF|100020562|09/05/2012|priority 4 |Q3|BP|GOM|ATCO NOPT NOTE NOCO|damage|damage from corrosion|scm hyd mech components|locking mechanism|other causes damage|damage from wear and tear|Incorrect workscope|Incorrect workscope
ZB|P6000105542|30/10/2015|priority 1 |Q1|unknown info customer_name|unknown info region|NOTI OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Gullfaks GSO 287 Pressure gauge SUBSEA|unknown info root_cause
ZF|P6000055605|20/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|assy|lack of training|Child QN for SCM # 320 SPFM comms issues|SPFM Comms Issues
ZD|100025661|01/02/2012|priority 3 |Q2|MARUBENI|GOM|NOTE NOCO ATCO NOPT|test|function|topside products|subsea control unit (scu)|test|incorrect set up testing|PT 22 SHOWING WRONG VALUES|PT22 Showing Wrong Values
ZF|P6000083428|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZE|P6000037215|05/05/2011|priority 3 |Q3|GJØA|unknown info region|NOPT ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|electric products|other electric products|qa qs qi|final inspection error|Photos Background needed in the workshop|Bad photo area
ZF|P6000076121|28/11/2011|priority 2 |Q3|CNOOC|unknown info region|NOCO NOPT NOTE ATCO|design|specification error|scm hyd mech components|check valve|vendor|wrong part delivered|(SS) Wrong check valve cap for SCM.| Wrong check valve cap for SCM
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZE|100029062|09/03/2009|priority 3 |Q3|TOTAL|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|BOM needs update|Update of voided PN with new PN
ZF|P7000024191|02/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm sem el opt component|scm|test|kongsberg|SEM A CAN BUS interface 3  out of order.|unknown info root_cause
ZF|P6000077638|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000008275|16/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|design error|Protection ring Ovalizada|Peça ovalizada
ZF|P6000132097|30/03/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|instrumentation|scm pressure transmitter|other causes damage|cause not found|HP2 PT showing incorrect value in EFAT|SCM return to MMR for service.
ZF|P7000000897|16/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|assembly|interface issue|scm el opt components|el. connector|other causes damage|damage from wear and tear|El. Connector with backshell broken|Equipamento retornou do campo
ZB|P6000042969|30/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOTE NOCO NOPT ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 06|Software improvement/correction
ZF|100025661|16/11/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|assembled incorrectly|scm el opt components|scm wiring|engineering|procedure error|Wiring mistake on COV HP|Wiring error. Procedure needed update.
ZF|P7000002082|05/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|electronic boards|other eletronic boards|other external causes|customer error responsibility|Sensores analógicos inoperantes|SCM MMR
ZF|100001156|30/07/2015|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|test omitted|scm|scm|other external causes|customer error responsibility|HFT omit from mobilisation of SCM|HFT omit from mobilisation of SCM
ZF|100067526|24/09/2012|priority 1 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOPT NOCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|cause not found|Filter line LP2 has been scratched up|Filter line LP2 in m.block  scratched up
ZF|P6000080343|09/11/2011|priority 3 |Q3|TULLOW|WEST AFRICA|NOTE NOCO NOPT ATCO|machining|burr chips|scm hyd mech components|hydraulic fittings|vendor|specification not followed|Possible chips in HP-Config Plug in SCM.|Plugs not cleaned by supplier.
ZF|P6000116166|01/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|machining|ring groove error|scm hyd mech components|other mechanical components|vendor|specification not followed|Screw do not fit on EC adapter.|Not investigated  scrapped
ZF|P7000024900|05/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|interface issue|scm hyd mech components|other hydraulic components|other causes damage|damage from wear and tear|PLUG FOR FILTER Danificado|unknown info root_cause
ZF|P6000104116|07/05/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|wrong part assembled|scm hyd mech components|other mechanical components|materials stores|improper packaging & storage|M6x20 screw is to short|One of the screws with incorrect length
ZF|3794920|12/05/2010|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|other external causes|customer error responsibility|No information on internal leakage|Missing information from Company
ZE|100035118|10/11/2016|priority 2 |Q3|WOODSIDE|unknown info region|NOTE ATCO NOCO|test|damaged during testing|scm hyd mech components|control valve|causes for improvement|documentation|High return pressure on HP|Continuously improvement of user doc's
ZF|7103382|16/12/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|physical|scm|scm|other external causes|customer error responsibility|Hp filter blocked by unindentifyed greas|SCM contaminated  crude oil?
ZF|7104670|06/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|test omitted|scm|scm|other external causes|customer error responsibility|Concession_FSM Test in HFT not performed|Test equipment not available
ZE|P6000088614|23/09/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|projects|documentation error|HFT evaluation|procedure confirmed ok by eng.kbg
ZE|P6000069056|26/10/2012|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|causes for improvement|process procedure not being followed|High pressure on return line|Incorrect assembly by operator
ZF|P6000055605|08/09/2011|priority 3 |Q3|SHELL|GOM|NOPT NOCO ATCO NOTE|other defect|physical|scm|scm|assy|missing parts|Fått feil deler fra lager|Incorrect picking from stock by operator
ZF|100035013|03/02/2009|priority 3 |Q3|SHELL|unknown info region|NOCO NOTE NOPT ATCO|test|missed operation|scm|scm|test|operator error|Brayco - transaqua mixed in hyperbaric|unknown info root_cause
ZF|P7000024191|11/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|assembled incorrectly|scm|scm|assy|operator error|Aterramento Não Conforme|unknown info root_cause
ZF|P6000031350|22/10/2009|priority 1 |Q3|GJØA|unknown info region|NOTE NOCO NOPT|documentation|incorrect certificates records|instrumentation|other scm instruments|test|incorrect set up testing|IWIS kommunikasjon problem!|Wrong software revision.
ZF|P7000016420|04/07/2011|priority 1 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO NOPT|test|function|electronic boards|main boards cpu & i o|test|incorrect set up testing|No replies on BooTP Call Table.|cause not  found
ZF|P6000108469|28/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|instrumentation|singlephase flow meter|engineering|continuous improvement|Solatron SPFM simulator has odd behavior| Continuous Improvement
ZF|P7000016420|17/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|assembled incorrectly|electronic boards|other eletronic boards|assy|damaged during assembly|Conector J4 da placa TIF SEM B|Dano Parafuso TIF
ZF|100031223|08/09/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|documentation|procedure process error|computer system software|sw|engineering|ecn error|Document not linked to material|Document not linked to part
ZF|P6000100953|03/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|procedure error|Measured 0Volt on EC2 pin 9 and 10|Step in procedure missing  wiring error
ZF|P6000104116|12/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|machining|surface finish error|scm hyd mech components|sem can|vendor|packaging handling|Scratch on o-ring surface  DIU13|Damage due to packaging
ZF|P7000039672|16/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Vazamento no Manifold block|123643 - BOSCH REXROTH LTDA
ZF|P6000063632|10/02/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|gas leak test not acording to LWI|Gas testing pressure reduced - HSE issue
ZF|7103233|20/10/2011|priority 2 |Q3|OVERALL PROJECT ROLL-UP|unknown info region|ATCO NOTE NOCO|test|component error|scm hyd mech components|locking mechanism|other causes damage|cause not found|Spring pin on locking mech broken.|Share pin broken during handling.
ZF|100052388|06/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|test omitted|scm sem el opt component|other scm sem el opt components|test|tooling|Mobilization not according to recom.|No choke bridge avlb. for FM test
ZF|P6000058949|11/02/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|test|test omitted|scm|scm|other external causes|customer error responsibility|SCM not mobilized acc to PSM|Customer Error/responsibility
ZF|P7000039672|08/03/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|damage from corrosion|scm hyd mech components|locking mechanism|vendor|coating defect|Oxidação nos Dog's|unknown info root_cause
ZF|100018531|05/12/2016|priority 3 |Q3|SHELL|unknown info region|ATCO|assembly|missing components|scm el opt components|el. connector|assembly|procedures not followed|MMR - EC4 Assembly without O-ring|Technician did not followed assy proced
ZB|P6000101955|07/10/2014|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|other defect|functional|scm|scm|other causes damage|cause not found|Tyrihans claim SPS250-001 SCM 01|unknown info root_cause
ZB|100017997|05/03/2010|priority 1 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|raw material|hardness out of tolerance|wocs control module (wocm) mech. w mb|outer can|other causes damage|damage from wear and tear|BPTH IWOCS Outer Can Repair|Roughness out of tol. on ED int. seal
ZF|P6000069056|22/05/2012|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|test|function|scm|scm|test|damaged during testing|SCM - communication with SEM A router|Follow-up in QN 200276026
ZF|P1000018406|06/04/2009|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|damage|damage during assembly|sensors|scm flowmeter|other causes damage|damage from wear and tear|Over-torque Of Outer Can|Over-torque Of Outer Can
ZF|P6000043714|05/07/2010|priority 2 |Q3|PETROBRAS|GOM|NOCO NOPT ATCO NOTE|assembly|assembled incorrectly|hydraulic products|coupler|assy|damaged during assembly|Change hydraulic coupler|Sharp edge on Male coupler   test equip.
ZF|P6000090632|21/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|test|function|scm|scm|engineering|engineering error|Signature curves not stable|Wrong flow restrictors listed in BOM
ZF|P6000121393|14/09/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|scm|scm|test|operator error|Suspecting 960 bar at supply lines.|Return pressure not monitored during hb
ZF|P6000029772|21/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|missed operation|electronic boards|main boards cpu & i o|engineering|specification error|Non functional SRM|Specification error
ZF|P6000079433|23/12/2011|priority 3 |Q3|CONOCOPHILLIPS|unknown info region|NOTE NOCO NOPT ATCO|design|dbi error|scm hyd mech components|other mechanical components|engineering|specification error|Wrong Bill Of Material and wrong parts|Coupler Interface on m.block (spc error)
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|100056261|05/03/2009|priority 3 |Q3|MURPHY|WEST AFRICA|ATCO NOPT NOTE NOCO|test|function|scm|scm|vendor|equipment malfunction| MURPHY AZURITE-LP SUPPLY FLOW METER|LP SUPPLY FLOW METER
ZF|P6000042969|25/11/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|part lost|scmmb|other hydraulic components|intercompany|kongsberg|Feil plukk av hydralic  plug hex hea|Wrong amount picked in warehouse
ZF|P6000039844|29/09/2009|priority 1 |Q3|SHELL|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (gas)|scm|scm|assy|operator error|Nitrogen leakage|Tube was not tightened sufficiently duri
ZF|P6000042970|03/11/2009|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE ATCO|test|function|scm|sem|test|incorrect set up testing|Unstable PT readings|Wrong configuration of  Sensor sim.
ZF|P7000001621|02/08/2010|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|welding|structural dimensional error|scm|scm|vendor|design error|Top Cover Hercules SN 03|Furação em desacordo
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|ATCO NOTE NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P7000024191|18/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|electronic boards|power units|other causes damage|cause not found|Perda de comunicação Global 13 SN-13 B|unknown info root_cause
ZF|P6000121393|31/01/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|other defect|part lost|object types to eng matl class|scm|engineering|engineering error|Missing Hyperbaric Test|TST60110167 lost when creating MRB
ZB|100067526|13/09/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|assembled incorrectly|scm|scm|service :|improper job preparation|SCM Fault reading value (Gullfaks)|Improper job preparation
ZF|100034440|30/11/2010|priority 2 |Q3|NYTT KONTROLLSYSTEM|unknown info region|NOCO ATCO NOTE NOPT|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P7000039672|06/02/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|object types to eng matl class|scm|vendor|equipment malfunction|SCM - FALHA NA LEITURA DO FLOWMETER|unknown info root_cause
ZB|100036936|13/11/2012|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|functional|customer compliant|unsatisfactory customer satisfaction|other external causes|customer error responsibility|Ingen kommunikasjon med SCM pga feil spe|FMC does not review well program
ZF|100020562|06/10/2009|priority 2 |Q3|BP|GOM|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm|scm|test|operator error|Water in module after hyperbaric test.|Operator error  see QNR/Disposition
ZF|P6000069056|30/08/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|drawing error|scm|scm|engineering|continuous improvement|SCM – ROV visibility of HP return port|ROV visibility in HP return port SCM
ZF|P6000149536|24/05/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|object types to eng matl class|scm_assy|other causes damage|planning error|Int.Dev. - No MOB Carried Out on SCM|unknown info root_cause
ZD|P7000000897|19/06/2012|priority 1 |Q2|SHELL|unknown info region|NOPT ATCO NOCO NOTE|test|function|scm el opt components|trafo unit|intercompany|kongsberg|SEM B communication failure|defect during function test
ZF|P6000069820|06/01/2012|priority 2 |Q3|CONOCOPHILLIPS|unknown info region|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Bug Fix
ZB|P6000063531|27/04/2017|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|damage|wear & tear|object types to eng matl class|scm|other causes damage|cause not found|Worn silicone compensator bladder|unknown info root_cause
ZF|P6000107981|30/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|Black Outer Can marking Lines Fading|Paint lines faded after hyperbaric
ZF|P7000039672|04/01/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|welding|material defect|scm hyd mech components|hydraulic manifold adapter plate|vendor|material error|ANOMALIA NA COLORAÇÃO DAS ADAPTERS PLATE|unknown info root_cause
ZF|P6000083428|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|SCM outercan drawing error
ZF|P6000028371|18/01/2008|priority 3 |Q3|SHELL|GOM|NOCO NOPT NOTE ATCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|2006 Shell Std SCM Restrictor Change|2006 Shell Std SCM Restrictor Change
ZF|P6000064909|08/06/2012|priority 4 |Q3|TOTAL|NORTH SEA|ATCO NOCO NOTE|test|function|scm|scm|test|incorrect set up testing|We did not get communicaton with the SCM|Network not in default mode
ZB|100020278|29/10/2009|priority 2 |Q1|EXXONMOBIL|unknown info region|ATCO NOCO NOTE|test|function|scm|scm|test|damaged during testing|09-MEGI-035 SS-W3 AWV PT failed/shorted|09-MEGI-035 SS-W3 AWV PT failed/shorted
ZB|P7000039672|15/11/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|electronic boards|main boards cpu & i o|vendor|second tier supplier issue|Presalt Claim 001 SEM #12|Defectiive comp. not trapped in test
ZB|P6000042968|29/09/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT NOTE NOCO ATCO|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM PXT 04|Software improvement/correction
ZF|P6000104111|20/09/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage during testing|object types to eng matl class|scm|test|other specify in comments|Child QN on defective P17|unknown info root_cause
ZF|P7000008275|15/02/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|outer can|other causes damage|damage from wear and tear|Oxidação na Outercan|unknown info root_cause
ZD|P6000080343|15/02/2012|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|documentation|missing certificates records|vendor quality system issue|quality management system|vendor|specification not followed|ATS-Missing Documentation|Missing required documentation
ZF|7104033|18/02/2014|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO|test|missed operation|scm|scm|test|operator error|Operated DCVs with too high pressure|Operator did not follow procedure.
ZD|100056261|25/06/2008|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|no DBI referenced|No DBI for part number
ZE|P6000074156|28/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM)Prellude-to blank out the ESRS|Prellude-to blank out the ESRS
ZF|7104670|10/04/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|missed operation|scm|scm|test|tooling|FSM Test in FAT not performed|Lack of test equipment
ZF|3812476|28/02/2018|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|other specify in comments|scm|scm|assembly|other specify in comments|Process not followed during PONC work|QA not informed
ZF|P6000093498|13/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|function|scm|scm|engineering|engineering error|WOCM -Fail to connect BMU-1A to consumer|Software causing component failure
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000058949|13/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|design|specification error|scm|scm|engineering|specification error|Wrong type of screws used on valves|BOM incorrect.M6 A4-80 to M6 inconell718
ZF|P6000084906|24/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|missed operation|scm|scm|test|missed operation|unknown info notification_desc|Picked wrong PT in warehouse
ZF|P6000104112|10/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|marking|marking content error|scm|scm|engineering|engineering error|Name plate has wrong max VAC|Engineering error  marking on name plate
ZF|P6000042968|01/09/2010|priority 2 |Q3|TOTAL|WEST AFRICA|ATCO NOCO NOPT NOTE|coating plating|painting defect|scm|scm|test|improper handling|Damage to surface coating|Storage handling of SCMs at Workshop
ZB|100067526|19/01/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|leakage (fluid)|scm|scm|other causes damage|cause not found|SCM - leakage|unknown info root_cause
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000068902|20/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT 23 failed during EE test|Unstable readings from PT.
ZF|P6000102554|23/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|design|specification error|scm|scm|engineering|specification error|Error in ELD60095678 TX/RX signal swappe|Wiring spec. error in ELD60095678
ZB|P6000042969|31/08/2010|priority 2 |Q1|TOTAL|WEST AFRICA|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|Punch List SCM IXT 17|Software improvement/correction
ZF|100049392|05/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|design|drawing error|scm|scm|other causes damage|cause not found|Missing GA DWG for SCM SYGNA|Missing GA DWG for SCM SYGNA
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|7101172|04/10/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO ORAS|machining|surface finish error|scm hyd mech components|outer can|materials stores|damage due to corrosion|Machining of sealing areas|Corrosion on sealing area for EC on OC
ZF|P7000001843|10/01/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|other causes damage|planning error|Problemas com o simulador PDG|unknown info root_cause
ZF|P6000093501|19/11/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|design|specification error|computer system software|etu sw|test|incorrect set up testing|PT smart retur is not in the config|No errors in the config
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|ATCO NOCO NOPT NOTE|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #8 Wiring|BPTH SKOFLO SCM SN #8 Wiring
ZF|P7000008275|06/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm|scm|test|incorrect set up testing|Alteração nos valores de DEMEG.|Simulador danificado
ZF|P7000039672|06/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|interface issue|scm hyd mech components|outer can|vendor|final inspection error|Outer Can does not mount|101545 - KRISTIANSANDS SKRUEFABRIKK &
ZF|P6000042968|17/08/2009|priority 3 |Q3|TOTAL|WEST AFRICA|NOCO NOPT NOTE|assembly|unknown info damage_desc|electronic boards|other eletronic boards|vendor|unknown info cause_desc|penetrator protection ring not in place|Error to be confirmed in QN200136757
ZF|100025661|23/06/2010|priority 2 |Q3|SHELL|GOM|NOTE NOCO ATCO NOPT|documentation|incorrect certificates records|scm|scm|intercompany|houston|Missing sign offs & Variance in book|Intercompany process differences
ZB|100048038|26/05/2010|priority 3 |Q1|CHEVRON|unknown info region|ATCO NOTE NOCO|raw material|defects in material|scm hydraulic|other scm hydraulic|assy|damaged during assembly|Agbami SCM SN 6 LP flowmeter not working|Agbami SCM SN 6 LP flowmeter not working
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #3 Wiring|BPTH SKOFLO SCM SN #3 Wiring
ZF|P6000147469|28/11/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|coating plating|painting defect|object types to eng matl class|scm_assy|vendor|coating defect|QUALITY ISSUE|unknown info root_cause
ZF|P6000083428|04/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|scm|scm|assy|damaged during assembly|CPU 24v drop|Bad wire connection > now corredted
ZF|100035013|08/07/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Silicone inside both SEM A and B|Optical penetrator leaking
ZF|P7000020444|25/06/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm el opt components|baseplate|vendor|packaging handling|Rosca dos Conectores Ruim|ODI
ZF|P6000080343|20/12/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|wrong part assembled|scm hyd mech components|sem can|materials stores|operator error|Wrong El cans was mounted|Picking error at warehouse
ZF|P7000024191|04/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|engineering|procedure error|Valores do DPT da SEM B fora do critério|Erro no critério do Procedimento
ZF|P7000039672|26/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|other defect|part lost|common misc fasteners metric|bolt|other causes damage|damage during transport|Falta do Parafuso|unknown info root_cause
ZB|100035013|11/11/2009|priority 1 |Q1|SHELL|unknown info region|ATCO NOCO NOPT NOTE|other defect|functional|scm|sem|other causes damage|cause not found|SUBSEA-Ormen Lange  Claim 026 SEMB |Power supply is damaged on SEM B
ZB|100052701|22/03/2010|priority 2 |Q1|STATOIL|NORTH SEA|ATCO NOTE NOCO|other defect|functional|customer compliant|noncompliance to customer requirement|vendor|material error|Guarantee claim TYR SCM Well A4|Solder debris on CPU and other cards
ZB|7104670|06/05/2008|priority 4 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|function|scm|scm|other external causes|customer error responsibility|Guarantee claim 127 - Failed SCM|Unknown reason for failure
ZF|100017997|30/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|procedure error|scm|scm|engineering|procedure error|Procedure issue( Hft 10029374) HC-1616|Procedure issue( Hft 10029374)
ZF|P6000068918|13/10/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|missing certificates records|scm hyd mech components|outer can|other causes damage|planning error|Delivery from Bandak Notodden AS.|Doc not released and missing final insp.
ZF|100035014|19/04/2018|priority 3 |Q3|unknown info customer_name|unknown info region|OSNO NOPT|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Company decided to not upgrade el.boards|unknown info root_cause
ZE|P6000093498|30/11/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|LLP WOCM Communication Failure|Error on SUPS SW  repair in SN300525765
ZF|P6000104116|24/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm|scm|engineering|dwg error|Part not according to drawing|See CRB for info  DRM60111600
ZF|P6000083428|23/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|design|drawing error|scm hyd mech components|outer can|other external causes|customer error responsibility|GA drawing DU600060362/B needs update|GA drawing DU600060362/B needs update
ZB|100020562|25/11/2008|priority 2 |Q1|BP|GOM|NOTE ATCO NOCO NOPT|test|leakage (gas)|scm hydraulic|other scm hydraulic|other causes damage|cause not found|Gas discharge from SCM|Gas discharge from SCM
ZF|100052701|26/08/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Internal leakage in HP function valve|Internal leakage in HP function valve s
ZE|100066325|13/12/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|component traceabilitynot maintained|scm|scm|qa qs qi|documentation error|Duplicate serial numbers created.|Guidelines to be checked
ZF|P6000116166|20/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZB|100056176|29/10/2009|priority 3 |Q1|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|test|test omitted|scm|scm|other external causes|unknown info cause_desc|DHI119 ÅsgB R-1H  comm probl w/ETU|Related to implementation of new equipm.
ZF|3787101|21/09/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|test|leakage (fluid)|scm|hydraulic valves|vendor|unknown info cause_desc|External leakage control valve|Holes for namepl drilled into hydr. line
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of resources|CAR 5 RCA Actions_2 from RPT10033107|unknown info root_cause
ZD|100052231|20/07/2010|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|functional|scm|scm|intercompany|kongsberg|NO DBI/ACCEPTANCE CRITERIA|NO DBI/ACCEPTANCE CRITERIA
ZE|100037965|23/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|function|scm|scm|causes for improvement|documentation|inconsistent valve signature|PRD updated  ref CM 500000338425.
ZB|P7000001843|15/03/2012|priority 1 |Q1|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|other defect|physical|scm|scm|engineering|engineering error|Interrompida instalação do SCM NS 02 MXL|unknown info root_cause
ZF|P6000109984|07/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm|scm|engineering|engineering error|oc not fit in outer can|Shallow O.C. interface followup200381445
ZF|P6000058949|14/02/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|SCM outercan drawing error
ZF|P7000001621|05/12/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm hyd mech components|outer can|other causes damage|cause not found|Fixação não adequada.|decorrente do processo de reparo
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO NOPT NOTE ATCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|SKOFLO SCM SN #2 Wiring|SKOFLO SCM SN #2  Wiring
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #11 Wiring|BPTH SKOFLO SCM SN #11 Wiring
ZF|100006609|17/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|imension (tolerance)|scm|scm|engineering|dwg error|furação da hose house|SCM MMR
ZF|P6000031350|18/12/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|incorrect certificates records|scm|scm|materials stores|operator error|Traceability issue|Pick list error  correct in SAP traceabi
ZF|P6000064910|30/05/2011|priority 2 |Q3|TOTAL|NORTH SEA|NOTE NOCO ATCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Power line error  GND error  => HSE risk|Wrong assembly of transformer
ZF|P6000050867|28/10/2009|priority 3 |Q3|PETROBRAS|GOM|NOTE NOPT ATCO NOCO|test|function|electric products|electrical components|vendor|equipment malfunction|Cascade DAS battery failure|Cascade DAS battery failure
ZB|P6000029772|10/09/2012|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|damage|damage during assembly|scm sem el opt component|optical penetrator (insert)|vendor|assembly error|Gjøa Claim 056 SRM 10|Fibreoptical penetrator incorrectly ass.
ZF|P7000008275|24/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|LP Change over valve internal leakage.|unknown info root_cause
ZF|P6000104112|05/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|component error|scm hyd mech components|other hydraulic components|vendor|equipment malfunction|PT53 is not working proparly.|Wrong values from PT  follow-up200411903
ZF|P6000079984|27/06/2012|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during testing|scm test stand|other mechanical components|vendor|specification not followed|Marks on baseplate mounted ECs|Wrong angle on connector wing on SCMTS
ZF|P6000090632|10/05/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|specification error|scm|scm|engineering|engineering error|Manifold block isnt marked  correct|System drawings not checked by E&S
ZF|100068622|04/08/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|drawing error|scm|scm|engineering|engineering error|Missing BOM & DWG for PN 100068622|Product structure is missing BOM & DWG
ZF|P6000125394|01/07/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Internal leakage too high from DCV's|Too high leakage from DCV's
ZB|P6000029747|28/01/2014|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|physical|scm|scm|other causes damage|damage from wear and tear|Oljelekkasje på SCM #7 levert fra FMC|Oil leakage from SCM in storaged
ZF|P7000024191|08/04/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|documentation|procedure process error|scm hyd mech components|other mechanical components|qa qs qi|documentation error|Não foi realizado o set out do PT|PT não teve o set out realizado
ZF|P6000076121|12/08/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|machining|burr chips|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Found parts after flushing the module|Contaminated m.block  chips found.
ZD|P6000028371|10/06/2008|priority 1 |Q2|SHELL|GOM|NOTE ATCO NOPT NOCO|test|function|sensors|flowmeter|vendor|unknown info cause_desc|MPFM are not working properly on SEM B|Error outside SCM  SW in test equipment
ZF|100054943|06/03/2008|priority 2 |Q3|WOODSIDE|unknown info region|NOPT NOCO NOTE ATCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000107991|29/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|scm|scm|test|incorrect set up testing|No communication with gauge sim|Operation mishap.
ZF|P6000039844|13/08/2009|priority 1 |Q3|SHELL|unknown info region|NOCO ATCO NOPT NOTE|coating plating|coating defect|scm|scm|assy|operator error|Rust appeared at SCM top plate area|Missing and wrong type Tectyl applyied
ZB|100035013|24/04/2009|priority 4 |Q1|SHELL|unknown info region|NOCO NOTE NOPT ATCO|damage|wear & tear|scm|sem|test|damaged during testing|GC#01 (ATS) SCM#13  Comm. failure during|Card damaged and replaced
ZF|P7000016420|14/07/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|coating plating|coating defect|scm|scm|other causes damage|cause not found|Danos superficiais no revestimento|Arranhões na peça
ZF|P7000020444|17/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|coating plating|coating defect|scm hyd mech components|locking mechanism|paintshop|paint defect|itens com revestimento diferente|Revestimento
ZF|P6000100953|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|NOTE NOPT NOCO ATCO|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|TDV spurious reading|TDV spurious reading
ZF|P6000122626|04/05/2017|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|electrical|component failure|object types to eng matl class|scm|electrical|machine malfunction|ZERO reading on DHI 2 on SEM B|ZERO reading on DHI 2 on SEM B
ZF|P6000098616|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P7000001621|25/02/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|damage|damage during assembly|scm|scm mounting base (scm|assy|damaged during assembly|Defeito no anel roscado|Por ca danificada
ZF|P6000068912|06/07/2011|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm sem el opt component|sem mech. components|assy|operator error|SEM not mounted in correct position|SEM not orientated acc to dwg
ZF|100020278|20/07/2010|priority 1 |Q3|EXXONMOBIL|unknown info region|NOPT ATCO NOTE NOCO|test|leakage (fluid)|hydraulic couplers|hydraulic coupler|intercompany|kongsberg|Coupler replacement|Coupler replacement
ZE|P6000074156|28/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|variance|enhance process|(CDM) SEM Not able to communicate|SEM Not able to communicate
ZB|P7000000897|23/11/2017|priority 3 |Q1|SHELL|unknown info region|NOTI NOPR ATCO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|BC-10 - SCM SN 15 - CIT4 UVM|unknown info root_cause
ZF|P7000001621|17/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|interface issue|instrumentation|scm chemical injection valve|other causes damage|cause not found|Fechamento da Outer  Can Hércules SN13|decorrente do processo de reparo
ZF|100048038|09/09/2008|priority 1 |Q3|CHEVRON|WEST AFRICA|NOCO ATCO NOPT NOTE|test|function|scm|scm|vendor|equipment malfunction|SCM incompatable|SCM Pressure Readings Incompatable
ZF|100020278|01/09/2009|priority 3 |Q3|EXXONMOBIL|unknown info region|ATCO NOTE NOPT NOCO|documentation|procedure process error|scm|scm|vendor|design error|Megi Sea SCM 30 - status buffer values|Procedure Needs to be updated
ZE|P6000107991|09/06/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|assembly|other specify in comments|F:IWCM backed out from funnel|Root cause not identified
ZB|100067526|12/04/2016|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage due to handling|scm|scm|other external causes|customer error responsibility|Quality deviations OH 048 Gullfaks|Customer Error/responsibility
ZF|P7000039672|05/04/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|assy|damaged during assembly|Parafuso DCV Cisalhado no Manifold Block|unknown info root_cause
ZB|100035013|06/12/2013|priority 1 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|functional|scm|scm|vendor|design error|Ormen Lange Claim SCM 21|Seacon optical connector issue
ZF|P6000050867|28/10/2009|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE NOPT|test|function|electric products|electrical components|vendor|equipment malfunction|Cascade DAS battery failure|Cascade DAS battery failure
ZF|100050519|11/11/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|leakage (fluid)|scm hyd mech components|check valve|vendor|equipment malfunction|SCM RELIEVING AT 5 PSI|Huge amount of thread sealing glue
ZF|P6000063531|23/01/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|test omitted|scm|scm|test|missing parts|SCM not mobilized acc. to FMC procedure|No test equipment available
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZB|P6000080678|06/12/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|electrical|component failure|object types to eng matl class|scm|vendor|assembly error|Persephone SCM #5 Kulite PT failure.|PT/TT failure
ZF|P6000093498|03/06/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|electronic boards|other eletronic boards|other causes damage|cause not found|SMU system error|Follow-up in ZE QN 200416121
ZF|P6000042969|01/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|instrumentation|scm flowmeter|vendor|equipment malfunction|LP Return Flowmeter not working properly|Flowmeter not counting minimum flow
ZE|P6000121268|20/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|qa qs qi|operator error|Leakage test outside criteria on FAT|Not possible to detect leakage at suppli
ZB|3812476|14/07/2007|priority 4 |Q1|STATOIL|NORTH SEA|NOCO NOTE NOPT ATCO|assembly|assembled incorrectly|customer compliant|noncompliance to customer requirement|other causes damage|planning error|F&D Skid not match the base plate on SCM|Correct skid not used
ZF|P6000122574|19/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|interface issue|scm|scm|engineering|continuous improvement|too long screw|Part & BOM updated  ref ECN 6187549
ZE|P6000088751|21/12/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Update KS200e SW to 610.0|To Update KS200e SW to 610.0
ZF|P7000039672|22/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|tooling|Gland does not fit on the Manifold Block|1756 -UVDAL MASKINFABRIKK A/S
ZF|P7000024900|21/03/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|interface issue|scm hyd mech components|other hydraulic components|materials stores|improper packaging & storage|Reverse flow of filter element|arrived damaged
ZF|P6000090632|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000055605|13/11/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|component error|instrumentation|scm pressure transmitter|vendor|equipment malfunction|Unstable reading on PT 3|Unstable PT  followed up in 200471731
ZF|P6000068912|21/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|SEM A  sensor fault|Follow up QN 200308426
ZF|100035118|08/10/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|assembly|physical damage|scm hyd mech components|other mechanical components|other causes damage|cause not found|broken bolt on EC8|Reason for damage bolt not found
ZE|P6000067527|28/06/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO OSNO|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Rosneft Lan Do  SCM  communication error|unknown info root_cause
ZF|P7000039672|29/07/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|component error|scm el opt components|scm wiring|assy|operator error|falha comunicação mrms fora do criterio|unknown info root_cause
ZF|P6000068912|18/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm|scm|assy|improper handling|Low voltage on SemB out 1|Wiring issue  improp. wire fixing in ESS
ZF|P6000104116|26/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|component error|scm|scm|test|incorrect set up testing|DIU SN 28 failed under hyperbaric|Failure in test equipment (jumper)
ZF|100038200|09/02/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|documentation|procedure process error|scm|scm|other causes damage|qn cancelled|Anadarko SCM TST Procedure|Anadarko SCM TST Procedure
ZF|P6000055213|08/10/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|design|specification error|scm|scm|engineering|engineering error|Wrong type of screws used on valves|Wrong type of screws used on valves
ZF|P6000126219|06/02/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|leak|object types to eng matl class|scm|test|lack of awareness|Water/oil contamination after hyperbaric|Base plate not clean when assemble SCM
ZF|7104670|09/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|damage|damage from corrosion|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|unknown info root_cause
ZF|100035013|15/11/2012|priority 2 |Q3|SHELL|unknown info region|NOPT NOCO NOTE ATCO|assembly|assembled incorrectly|scm sem el opt component|optical penetrator (insert)|vendor|clarification|Damaged fiber penetrator Sem A|Case follows in QN200335518
ZF|P7000000229|26/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|damage|damage from corrosion|scm hyd mech components|outer can|engineering|specification error|Top plate screws damaged .|parafuso emperrado
ZF|100015314|17/12/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|missing user documentation (customer)|scm|scm|engineering|continuous improvement|HFT not linked to PN 100015314 in SAP.|HFT not linked to P/N.
ZF|100038200|01/09/2010|priority 2 |Q3|BHP BILLITON PETROLEUM AMERICAS  INHOUSTON STOCKING SCM MK II (15K)|unknown info region|NOPT NOCO NOTE ATCO|design|procedure error|scm|scm|engineering|procedure error|HFT-0000021872 issues for GK_V SCM 63|HFT-0000021872 issues for GK_V SCM 63
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOCO NOTE|design|specification error|scm|scm|engineering|continuous improvement|Gluing of DHI212 board|WD design improvement.
ZF|P7000024191|12/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|component error|scm hyd mech components|check valve|other causes damage|damage from wear and tear|check danificada durante o teste|unknown info root_cause
ZB|100052701|17/06/2010|priority 3 |Q1|STATOIL|NORTH SEA|ATCO NOTE NOCO|other defect|functional|scm hyd mech components|check valve|vendor|clarification|Tyrihans Claim 015 MIV |unknown info root_cause
ZF|P7000024191|29/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|test omitted|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|Man. Global #14 Can Bus & Serial Line|Lab test box with problem.
ZE|P6000090632|30/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|wocs|installation workover control system (iw|variance|capture mistake|(SS)WOCM side B is faulty|unknown info root_cause
ZF|P6000029772|23/02/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|electric products|electrical components|test|improper handling|No communicate with DWDM|Most likely damaged contacts
ZF|P6000064911|06/06/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|wrong part assembled|scm|scm|engineering|specification error|Wrong PN in bom|Lack of inter-project communication
ZB|100020562|24/04/2009|priority 2 |Q1|BP|GOM|NOPT NOTE ATCO NOCO|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|Non functioning PT|Non functioning PT
ZF|P7000039672|15/02/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|object types to eng matl class|scm|intercompany|kongsberg|SCM - Falha de comunicação DHI / DCVs|unknown info root_cause
ZE|7104075|23/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|Catastrophic FailureSCM Locking Mech-RED|unknown info root_cause
ZF|7104033|29/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|damage|wear & tear|scm|scm|other causes damage|cause not found|W&T repair of sealing surfaces|unknown info root_cause
ZF|P6000104116|26/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|damage|damage during testing|electric products|electrical components|test|incorrect set up testing|Unit B side comunication failure|Incorrect jumper in hyperbaric chamber
ZF|P6000110991|01/03/2017|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|software|program configuration|object types to eng matl class|scm|engineering|procedure error|Centrica Vale SCM fault dueto config DHI|Procedure misinterpreted
ZF|P7000016420|02/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|cleanliness|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Interior de Manifold Block com cavacos|Bosch - manifold block c/ cavacos
ZE|100001156|23/02/2015|priority 2 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|High Voltage applied to SCM|Human error  no change of procedure
ZF|P6000068902|17/04/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|assembled incorrectly|scm|scm|assy|missing parts|Smart ret. fitting missing o-ring|O-ring not re-installed on smart return
ZF|P6000088614|10/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|design|drawing error|scm hyd mech components|outer can|engineering|dwg error|Top plate outside acceptance criteria|Top plate outside accept criteria. DWG
ZF|P6000102554|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000043122|31/08/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOPT NOCO NOTE|test|function|scm|scm|assy|operator error|Hydraulic filter fitted up side down|Operator error  training is given
ZF|P7000000229|30/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|other defect|functional|scm sem el opt component|other scm sem el opt components|vendor|maintenance|Teste Funcional - Frade #08|MMR SCM
ZF|P7000024900|27/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|materials stores|improper packaging & storage|Nao conformidade Adapter Plate (LP)|unknown info root_cause
ZF|P1000018406|30/01/2012|priority 3 |Q3|BP|unknown info region|NOCO NOTE NOPT ATCO|design|procedure error|scm|scm|engineering|procedure error|Weld Procedure not BP Approved|Weld Procedure not BP Approved
ZF|100052701|11/10/2012|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|Tyrihans 10 Pressure Test Leakage|Leakage tests w/SCM procedure errors
ZF|100036936|11/03/2005|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly test|do not use|scm|sem|engineering|dwg error|To frequently  no response on SIO CARD|HW/SW timing conflict at power-up
ZB|100056918|11/07/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|assembled incorrectly|scm|scm|assy|improper handling|WEL Incorrect SCM installed|unknown info root_cause
ZF|P6000063531|09/11/2010|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|documentation|procedure process error|computer system software|network config|engineering|procedure error|Error on folder on N:/ Server.|unknown info root_cause
ZF|P6000076121|08/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|imension (tolerance)|scm hyd mech components|outer can|vendor|specification not followed|Bracket in outercan conflict|Bracket conflict inside outercan
ZE|P6000088751|18/05/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOPR OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Improvement for SN 300644919|unknown info root_cause
ZB|P6000105708|16/02/2016|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|physical|scm|scm|vendor|assembly error|Julia SRM #4 Defecte Bladder|Contamination i bladder
ZF|P6000102687|10/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZD|7104075|23/07/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|machining|surface finish error|scm|scm|vendor|specification not followed|Face and Piston surface out of specs.|EC seal surface finish out of tolerance
ZF|P6000103208|06/11/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Wrong position of SEM penetrator|SEM rotated wrong during assembly
ZB|100046387|21/04/2008|priority 3 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|assembly|unknown info damage_desc|ss umbilical & flowline well jumper|termination head|engineering|engineering error|Guarantee claim 154 - Failure on jumper|unknown info root_cause
ZF|100035118|10/02/2009|priority 3 |Q3|WOODSIDE|unknown info region|NOTE NOPT NOCO ATCO|test|unknown info damage_desc|scm|sem|vendor|unknown info cause_desc|Problems during DHI test|No functional failure  only houskeeping
ZE|100064910|12/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|interface issue|scm|scm|obsolescence issue:&|general|Better design to get easy closing  SCM|Proposals in MOM attached
ZF|P6000068924|09/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|other defect|functional|scm|scm|vendor|design error|Clov SRM # 16 Possible Optical p failure|Leaking optical penetrator
ZF|P7000039672|17/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|function|scm hyd mech components|check valve|vendor|equipment malfunction|check valve abrindo fora do criterio|unknown info root_cause
ZF|P7000024900|30/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|assembly|component error|scm el opt components|other el opt components|assy|cause not found|Variação na leitura do WLD|unknown info root_cause
ZE|P6000062990|09/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|HFT Documentation Defects|HFT Documentation  Defects
ZF|P6000105542|14/12/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|missed operation|instrumentation|other scm instruments|other causes damage|cause not found|Unable to perform test according to HFT|unknown info root_cause
ZF|100056176|09/10/2009|priority 3 |Q3|STATOIL|NORTH SEA|NOCO NOTE ATCO NOPT|test|test omitted|scm|scm|other external causes|customer error responsibility|B&B03 SCM not mobilized acc. to PSM|Consession
ZF|P6000068902|07/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000055605|19/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|assembly|interface issue|scm hyd mech components|other mechanical components|vendor|specification not followed|TOP PLATE|Wrong angle on guide rail
ZF|P6000068902|05/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZD|P6000068912|30/07/2013|priority 2 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|marking|no marking|scm hyd mech components|hydraulic coupler|intercompany|kongsberg|Missing Valve Cap P/N:100014108 from SCM|Missing protection cap
ZF|P7000000897|14/09/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage due to handling|ss compl. & w.over xt general|tree assembly|assy|damaged during assembly|Falhas no acabamento|FMC BRASIL
ZF|P6000068912|04/05/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|interface issue|scm sem el opt component|optical penetrator (insert)|engineering|engineering error|O rings for optical couplers missing|Proj.mistake?O-rings not included in BOM
ZF|P7000039672|07/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|function|instrumentation|scm pressure transmitter|vendor|equipment malfunction|Incorrect reading of pressure transducer|2932 - Scan  Sense AS
ZD|100048038|07/10/2008|priority 1 |Q2|CHEVRON|WEST AFRICA|ATCO NOCO NOPT NOTE|damage|damage during transport|scm|scm|other causes damage|damage during transport|Agbami SCM #32 Damaged During Shipping|Agbami SCM #32 Damaged During Shipping
ZF|100015538|27/02/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|dbi error|scm|scm|other causes damage|no noncompliance|Missing DBI on various PN|Old parts not transferred to TCE.
ZB|100020278|22/04/2008|priority 2 |Q1|EXXONMOBIL|unknown info region|NOTE NOCO|test|function|scm hydraulic|hydraulic control valves|other causes damage|cause not found|PMV failed to operate via SCM|PMV failed to operate via SCM
ZE|P6000080678|11/12/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure not being followed|(CDM) SCM  Voltage issues|Voltage issue
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|NOCO NOPT ATCO NOTE|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
ZD|P6000080678|10/12/2015|priority 4 |Q2|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|procurement|incomplete kit of parts|scm|scm|vendor|missing parts|(CDM) SCM API Bucket Missing|Missing component of SCM
ZF|100037229|24/04/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE|test|unknown info damage_desc|scm|scm|engineering|unknown info cause_desc|Extra test FAT test section 7.4.9|SCM tested without Gauge
ZF|P6000090632|20/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|other causes damage|damage from wear and tear|Silicone Leakage at bladder hose|Silicone Leakage at bladder hose
ZF|P7000039672|10/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|assembly|assembled incorrectly|scm el opt components|trafo unit|intercompany|kongsberg|ALLIGNMENT MARK OUT OF PLACE|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZB|100035119|25/09/2012|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOTE|other defect|functional|scm|scm|engineering|engineering error|Warranty Claim SCM S/N 110|unknown info root_cause
ZF|P7000001843|07/03/2014|priority 1 |Q3|PETROBRAS|unknown info region|NOCO NOTE ATCO|test|function|electronic boards|other sem (non standard)|test|incorrect set up testing|MMR - TUM not communicating|Overvoltage by incorrect set up
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|NOPT NOTE NOCO ATCO|machining|position error|scm|scm|other causes damage|qn cancelled|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|7101401|23/06/2016|priority 3 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTE NOPT|test|leakage (gas)|scm hyd mech components|outer can|service :|damaged during installation|MMR - Outer Can did not reach Vacuum|SCM felt down on seabed
ZF|P6000029747|18/11/2011|priority 3 |Q3|ENGIE|NORTH SEA|NOCO ATCO NOTE|other defect|functional|scm|scm|vendor|equipment malfunction|Repair SCM Internally detected failure|PT fault
ZF|P6000108025|05/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Too high leakage during leakagetest|DCV leakage outside acceptance criteria
ZF|P6000088604|18/03/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|engineering|continuous improvement|(CDM) check valves Leaking|Check valves Leaking
ZF|100035013|17/08/2010|priority 3 |Q3|SHELL|unknown info region|NOTE NOPT NOCO ATCO|assembly|wrong part assembled|computer system software|basis e sw|qa qs qi|operator error|Downloaded wrong SW to SCM|unknown info root_cause
ZF|100056176|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO NOPT|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P7000039672|12/11/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|component error|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|assy|operator error|Flowmeters sem leitura pela SEM A|unknown info root_cause
ZF|P6000104115|08/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm el opt components|trafo unit|engineering|engineering error|High current readings from PSDM.|Extra grounding added  not as specified
ZF|P6000068924|16/11/2011|priority 1 |Q3|TOTAL|unknown info region|NOCO NOTE ATCO NOPT|assembly|assembled incorrectly|electric products|electrical wire|engineering|engineering error|Wrong use of miniseal|Wiring list incorrect. followup200315427
ZF|100030542|21/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|damage|wear & tear|scm hyd mech components|outer can|other causes damage|cause not found|W&T - Corrosion on EC seal Surface|Wear and tear.
ZB|7104670|22/07/2018|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI NOPR OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|CIDV1 fault detected during SCM mob|unknown info root_cause
ZF|P7000039672|29/02/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|physical damage|scm el opt components|el. connector|vendor|final inspection error|Term Shell Danificado - Conector ODI|unknown info root_cause
ZF|P6000069056|07/12/2011|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|test|function|scm sem el opt component|sem cable & wiring|assy|damaged during assembly|SCM  earth fault in el. conn. EC1|Ground wire too close to pin on board
ZF|100037966|04/04/2008|priority 2 |Q3|BP|unknown info region|ATCO NOCO NOTE NOPT|other defect|functional|scm|scm|other causes|do not use|FPS NCR26 - Comnction Loss on SCM SEMA/B|Still to be determined
ZF|P6000064909|08/08/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|marking|marking content error|scm hyd mech components|control valve|assy|operator error|Wiring falure on COVHP|Marking on soleonide A and B swithed
ZF|100068622|01/12/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|test|missed operation|scm|scm|test|tooling|Multiphase Simulator testing InHouse/FAT|Lack of functional CPI test equipment
ZE|P6000068924|07/01/2013|priority 3 |Q3|TOTAL|unknown info region|NOPT NOTE ATCO NOCO|assembly|assembled incorrectly|scm hyd mech components|hydraulic coupler|qa qs qi|operator error|Loose HCs in SRM manifold block.|Couplers most likely not torqued
ZF|100048038|23/03/2018|priority 2 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|documentation requirement|other specify in comments|SCM  Equipment structure in SAP missing.|Parts not inculded in the eqp. structure
ZF|100052701|05/10/2011|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|leakage (fluid)|scm|scm|assy|operator error|HP valves damaged do to high return pres|Return hose blinded  SCMTS
ZF|100016901|22/06/2010|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|documentation|missing certificates records|scm|scm|test|operator error|Variance Form in SO book|ACCEPTED
ZF|P7000039672|11/11/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|other defect|part lost|scm el opt components|el. connector|other causes damage|cause not found|FALTA DE MATERIAL DO CON. EL. DA O. CAN|Teledyne Oil & Gas
ZF|P6000073613|13/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100020562|28/07/2009|priority 3 |Q3|BP|GOM|NOPT ATCO NOTE NOCO|change deviation request|conversion approval|scm|scm|other external causes|customer error responsibility|BPTH SKOFLO SCM SN #21 Wiring|BPTH SKOFLO SCM SN #21 Wiring
ZD|100050519|04/04/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|missing certificates records|test and transportation|other scm test & transport equipment|intercompany|kongsberg|Certs issue|unknown info root_cause
ZD|P6000068902|26/03/2014|priority 2 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|marking|no marking|scm|scm|other causes damage|damage during transport|Wrong Tag marking|unknown info root_cause
ZF|P6000079032|27/01/2012|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|design|drawing error|scm hyd mech components|hydraulic manifold adapter plate|engineering|engineering error|Insufficient wall thickness in m. block|Ref. QN 200241870
ZF|100048038|14/01/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|machining|inside diameter error|scm|scm|vendor|specification not followed|screw too large diameter for hole|max at d1 is 8mm for M6 screw
ZF|100056443|08/03/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|missed operation|instrumentation|other scm instruments|other causes damage|cause not found|CR Unable to perform test accord to HFT|Lack of test equipment
ZF|7102969|25/09/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|coating plating|painting defect|scm hyd mech components|outer can|paintshop|paint defect|Incorrect coating application|unknown info root_cause
ZF|3805796|19/10/2010|priority 2 |Q3|CONOCOPHILLIPS|unknown info region|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|projects|material error|Material not delivered to plant|Taken into Aberdeen under wrong Project
ZB|100048038|27/02/2008|priority 1 |Q1|CHEVRON|WEST AFRICA|NOTE NOCO ATCO NOPT|test|function|scm electrical|pressure transducers|vendor|equipment malfunction|ICV3 PT sensor is reading erratic values|ICV3 PT sensor is reading erratic values
ZF|P6000104113|02/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|other hydraulic components|test|operator error|Leak of hydraulic fluid from MCM|PT not torqued correctly
ZF|P6000058949|10/06/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|documentation|procedure process error|scm|scm|engineering|engineering error|Missing information about looping.|Incorrect flushing procedure
ZF|P6000108542|24/09/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|test|function|instrumentation|scm chemical injection valve|other causes damage|cause not found|SCM #2 fails on CIMV|SCM #2 fails on CIMV
ZE|P6000122626|07/02/2019|priority unknown info priority|Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SCM  Update to Agbami HFT 615 Procedure|unknown info root_cause
ZF|P7000000897|25/04/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm|scm|test|incorrect set up testing|Pre charge hose out of range|Pre charge N² hose out of specification
ZF|P6000144559|22/08/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|machining|position error|scm hyd mech components|outer can|vendor|specification not followed|Outer can drain port not correct.|Drain ports are 10 CM to high.
ZF|P6000104116|08/05/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|design|specification error|computer system software|sem tpu config|engineering|engineering error|Unfunctional Configfile|unknown info root_cause
ZF|P6000069820|16/05/2011|priority 1 |Q3|CONOCOPHILLIPS|unknown info region|ATCO NOTE NOCO|design|specification error|scm|scm|engineering|continuous improvement|Gluing of DHI212 board|WD design improvement.
ZF|P6000100953|11/12/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|leakage (fluid)|scm|scm|vendor|equipment malfunction|Too much leakage during leakage test FAT|Fault finding in QN 200360907
ZE|P6000055605|30/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|function|scm|scm|causes for improvement|lack of training|SEM B absolute pressure 1200 mBar|Operator not trained correctly
ZF|P7000008275|24/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|scm sem el opt component|sem cable & wiring|intercompany|kongsberg|Issue on PT 12 and PT 17.|Tambau Project
ZF|P6000090632|06/07/2015|priority 2 |Q3|CHEVRON|unknown info region|NOTE NOCO ATCO|test|component error|scm|scm|vendor|equipment malfunction|WOCMMMR Wheatstone PT Variance|Followed up in QN 200451039
ZF|100048038|14/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|test omitted|electronic boards|other sem (non standard)|test|operator error|ESS is not fully performed|FMC standard procedure used in testing
ZF|100050520|02/06/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|physical|fks quality system issues|noncompliance to industrial standard|qa qs qi|goods receiving inspection error|Received SCM not according to THI|Damage during shipping
ZF|P7000020444|20/05/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|imension (tolerance)|scm hyd mech components|sem bracket|vendor|specification not followed|furaçao desalinhada|Bracket não monta
ZE|P6000104116|19/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|damage|damage during testing|electric products|electrical components|causes for improvement|process procedure ineffective|Unit B side comunication failure|Insufficient check of test set up
ZF|P6000103208|03/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|test|leakage (fluid)|scm|scm|assy|operator error|Leakage between adapter and manifold b.|Wrong torque used procedure not followed
ZF|P7000020444|22/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|Flowmeter não conforme|unknown info root_cause
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZF|100020562|22/10/2009|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|specification error|test and transportation|etu smart tool hw|other causes damage|no noncompliance|BPTH ETU Text File Punchlist Items|BPTH ETU Text File Punchlist Items
ZB|7101463|27/08/2008|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|wocs control module (wocm) mech. w mb|locking mechanisms|vendor|equipment malfunction|Latching Mechanism will not unlatch|unknown info root_cause
ZF|P6000029772|06/04/2016|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|interface issue|scm sem el opt component|optical penetrator (insert)|engineering|engineering error|Clearence issue mounting fiber pen.|Consequence of changin fiberpenetrator
ZE|P7000039672|06/02/2018|priority 4 |Q3|unknown info customer_name|unknown info region|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|outer can|assembly|procedures not followed|RCA _ SCM colapsado durante teste Hiperb|unknown info root_cause
ZF|100037427|12/06/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|engineering|specification error|DHI 113 functionality Rosa Capital Spare|Old specification  No update action
ZE|P6000068912|22/11/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|missed operation|scm|scm|projects|material error|S/N 6 was sent to Dunfermline|Damaged by faulty PT
ZF|P7000016420|05/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|baseplate|vendor|specification not followed|Base Plate P55/10|USILIDER - BASE PLATE
ZF|100052701|01/09/2009|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO|test|function|scm|scm|assy|operator error|MPFM uanble to connect with SEM A.|Poor crimp on cableshoe
ZB|100015314|04/11/2008|priority 2 |Q1|TAQA BRATANI LIMITEDOVERALL PROJECT ROLL-UP|unknown info region|NOCO NOPT ATCO NOTE|design|unknown info damage_desc|scm|scm|engineering|specification error|SCM Ruptured Bladder|Storage conditions (temp fluctuation)
ZF|P6000069820|06/01/2012|priority 2 |Q3|CONOCOPHILLIPS|unknown info region|NOPT ATCO NOCO NOTE|other defect|functional|scm|scm|intercompany|kongsberg|(SS) MRM Software Version update|MRM Software Bug Fix
ZF|P6000108025|16/01/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|component error|scm|scm|vendor|equipment malfunction|HP flowmeter not measuring correctly|Unstable readings from HP flowmeter
ZF|100046112|02/05/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|test|function|scm|scm|vendor|material error|Lost communication from SEM A|short in DHI-board shorted 24V supply
ZF|100048038|08/08/2008|priority 1 |Q3|CHEVRON|WEST AFRICA|NOCO NOTE ATCO NOPT|damage|damage during testing|scm|scm|assy|operator error|Damaged plug from  EC12 Sensor Harness|unknown info root_cause
ZF|P6000055605|08/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|function|scm|scm|test|operator error|Wrong pressure on PT when operating CVHP|Wiring error. dicovered in hyper.b.ZE QN
ZF|P7000001621|04/11/2013|priority 1 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm hyd mech components|control valve|test|damaged during testing|MMR- CVLP 29 LEAKAGE|unknown info root_cause
ZF|100055762|17/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|missed operation|scm|scm|test|tooling|Wetgas test not performed|Lack of test equipment
ZF|P6000119039|21/01/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|imension (tolerance)|scm hyd mech components|other hydraulic components|machine shop personnel|operator error|Vacuum rør for kort fra lager|Vacuum pipes cut too short
ZF|P6000121393|05/08/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|scm|scm|other causes damage|no noncompliance|Canbus 5 on SEM B fault on test|NO SCM failure  => TS cabling issue
ZF|100049000|06/06/2011|priority 3 |Q3|BP|GOM|NOCO ATCO NOTE NOPT|damage|damage during assembly|hydraulic products|coupler|assy|damaged during assembly|Replace HC 10 and HC 22|Replace HC10 & HC22
ZE|P6000103208|19/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|measuring analysis & improvement|variance|enhance process|Faulty test cable used during SCM FAT|unknown info root_cause
ZF|P7000039672|13/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Trafo sem marcação de alinhamento|unknown info root_cause
ZF|P6000042968|08/01/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|component error|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|TIF board err after XT install incident|Unknown
ZB|P6000104112|23/08/2017|priority 3 |Q1|unknown info customer_name|unknown info region|NOPR NOTI OSTS|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|Egina WC 0023 -SCM 21 Conn stuck.|unknown info root_cause
ZF|P6000039844|05/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|specification error|computer system software|sem tpu config|engineering|engineering error|Fault on config|unknown info root_cause
ZF|P7000039672|19/09/2017|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|misalignment interface error|object types to eng matl class|scm|vendor|assembly error|SEM Bracket - Misaligned / Desalinhada|unknown info root_cause
ZE|P7000039672|03/12/2013|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|assembly|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|capture mistake|Adapter Plate danificada durante desmont|BOSCH REXROTH LTDA.
ZB|P6000068902|11/07/2014|priority 3 |Q1|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|functional|instrumentation|scm pressure transmitter|vendor|equipment malfunction|Clov Claim 001 - PT on SCM 012|PT failure
ZF|P6000147859|28/06/2018|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|test|function|object types to eng matl class|tree_assembly|intercompany|kongsberg|DHI Issues during Victor Charlie Comms|CPI - DHI Card faulty
ZF|7104033|17/02/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|Misleading info. in test procedures SCM|Test procedures improved for clarity
ZF|P6000088751|04/11/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|component error|object types to eng matl class|scm|vendor|equipment malfunction|PT 58 failed|PT followed up in ZE QN200519225
ZF|P7000008275|17/07/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|function|scm|scm|vendor|equipment malfunction|Valores abaixo do critério de aceitação|Simulador Apresentou avaria
ZF|3810872|19/01/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|machining|position error|scm hyd mech components|other mechanical components|other causes damage|cause not found|Offset on holes for lifting sling|Production error when SCM were produced
ZE|100051991|26/04/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|test|procedures not followed|Vincent  SCM  Flushing not done|SCM Flushing not done
ZE|100020562|20/02/2009|priority 2 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|sem|causes for improvement|documentation|CAR1 Implement RCA Actions_1 RPT10033107|Implement RCA RPT10033107 Recommendation
ZF|P7000001843|08/04/2014|priority 2 |Q3|PETROBRAS|unknown info region|ATCO NOTE NOCO|damage|damage during testing|scm|scm|test|damaged during testing|MMR - SEMs A and B Communication Failure|unknown info root_cause
ZF|P7000039672|13/03/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|marking|no marking|scm el opt components|trafo unit|intercompany|kongsberg|Trafo sem marcação de alinhamento|FMC KONGSBERG SUBSEA AS
ZE|P6000068924|26/04/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Proced update SRM HFT - Luanda Workshop|Update is followed up in QN 200439169
ZF|100037965|14/06/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|change deviation request|part substitution request|scm|scm|other causes damage|planning error|CREATED IN ERROR|unknown info root_cause
ZF|P6000069056|06/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P7000016420|14/10/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|missed operation|test and transportation|other scm test & transport equipment|test|incorrect set up testing|SRT  P-55 SN09|lab test box com fio solto
ZE|P6000088604|07/10/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|intercompany|kongsberg|(CDM) Wheatstone  SCM  Pressure Fault|Faulty gas accumulator fitting of SCM
ZB|100046387|13/07/2009|priority 4 |Q1|STATOIL|NORTH SEA|NOTE NOCO ATCO|test|function|topside products|subsea control unit (scu)|other causes damage|no noncompliance|No communication with N-1SEM A|SCM needs to be upgraded
ZF|3812476|28/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO NOPT|damage|damage during testing|scm|sem|vendor|wrong part delivered|Identified defect rectifier bridge|Used component with wrong rating
ZF|100034440|26/02/2009|priority 3 |Q3|NYTT KONTROLLSYSTEM|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm|scm|other causes damage|no noncompliance|Loose EC connectors|Accepted Per LLOG Representative
ZF|100049000|19/07/2011|priority 3 |Q3|BP|GOM|ATCO NOCO NOPT NOTE|machining|position error|scm|scm|other causes damage|no noncompliance|Dial caliper coupler measurements|Dial caliper coupler measurements
ZF|P6000088626|12/04/2018|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|damaged during testing|scm|scm|assy|operator error|SCM Installation of SCM on SCMMB PMA WS2|Dust prot. on SCCMB when SCM was mounted
ZF|P6000069056|18/08/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT|test|function|scm|scm|assy|operator error|Dual PT feiler|Operator forgot to connect wire 129
ZF|P6000063531|01/02/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|test omitted|scm|scm|other external causes|customer error responsibility|Mob incomplete - lack of test equipment|SESI sold to 3rd party
ZF|P6000121393|12/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|machining|miscellaneous|scm|scm|materials stores|improper packaging & storage|o-rings on plug|Improve storage control on o-ring
ZB|100035014|04/03/2010|priority 2 |Q1|STATOIL|unknown info region|NOCO ATCO NOTE|other defect|functional|electronic boards|other eletronic boards|projects|material error|GC#34  Serious I/O-problems on TemplateA|unknown info root_cause
ZE|P6000091085|11/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|documentation|(N) - Child CAR -OWIRS- Deadman sequence|unknown info root_cause
ZF|P6000080343|07/12/2012|priority 2 |Q3|TULLOW|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Lock mech screws broke during test|Bolts missing in SCM locking mechanism.
ZF|100020562|21/01/2010|priority 3 |Q3|BP|GOM|NOCO NOPT ATCO NOTE|test|component error|scm|scm|other causes damage|unknown info cause_desc|BPTH SCM 26 LP supply PT issues|BPTH SCM 26 LP supply PT issues
ZF|P7000001843|02/08/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|function|scm hyd mech components|control valve|vendor|equipment malfunction|Flow meter retorno LP e retorno HP|Flow technology
ZF|P6000068912|21/10/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|assembly|assembled incorrectly|scm|scm|assy|operator error|loose screws on outercan|Five un-torque screws found by QA
ZB|100036936|26/11/2010|priority 4 |Q1|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|other defect|functional|scm test stand|electrical jumper|test|damaged during testing|Error on PCIM-B|Damage during testing on PCIM
ZF|P6000058949|29/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|ATCO NOTE NOCO NOPT|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|Engineering error
ZF|P6000076121|04/01/2012|priority 1 |Q3|LIU HUA 4-1|unknown info region|NOTE ATCO NOPT NOCO|other defect|functional|scm|scm|intercompany|kongsberg|(SS) Frequency and Software issue in SCM|Frequency and Software issue in SCM
ZB|100049000|29/08/2008|priority 1 |Q1|BP|GOM|ATCO NOTE NOPT NOCO|damage|unknown info damage_desc|scm electrical|processor pcbs|vendor|material error|DHFC SCM 06 SEM A RAM Warning|Defective RAM chip
ZF|P7000001843|20/04/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|coating plating|coating defect|scm hyd mech components|locking mechanism|other causes damage|damage from wear and tear|revestimento|Revestimento danificado
ZB|P6000065528|03/03/2014|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO|assembly|imension (tolerance)|fks quality system issues|engineering system|other causes damage|no noncompliance|LT NCR 23: Gas Accumulator in WOCM|unknown info root_cause
ZB|P6000065886|12/02/2013|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|other causes damage|damage from wear and tear|Alve Claim 222 SCM failed SEM B|Electronic card failure
ZE|100056443|06/04/2017|priority 2 |Q3|EDISON/EDF|NORTH SEA|OSTS NOPR|unknown info damage_group_desc|unknown info damage_desc|unknown info object_part_group_desc_|unknown info object_part_desc_|unknown info cause_group_desc|unknown info cause_desc|SEM Uncontrolled DCV oper.(Ribbon cable)|unknown info root_cause
ZF|100036936|27/01/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|marking|marking location error|scm hyd mech components|outer can|engineering|dwg error|Missing information in DWG for SCM|Missing items for EC's in DWG
ZF|7103233|21/10/2010|priority 2 |Q3|SUNCOR|unknown info region|NOTE NOPT NOCO ATCO|documentation|procedure process error|scm|scm|qa qs qi|goods receiving inspection error|SCM returned to FMCK on MMT|Goods Receiving Inspection error
ZE|P6000074156|06/01/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|new way to attach earthing rail|New parts in project BOM.
ZF|P6000138867|24/10/2016|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|object types to eng matl class|scm|vendor|equipment malfunction|PT issue during hyperbaric|PT issue during hyperbaric
ZF|P7000000897|08/08/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage from corrosion|scm hyd mech components|baseplate|other external causes|customer error responsibility|screw stuck in base plate.|SCM MMR
ZF|100049392|04/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|missed operation|scm|scm|qa qs qi|goods receiving inspection error|SCM not washed after retrieved (F&D09)|SCM not washed after retrieved (F&D09)
ZF|P7000024191|04/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|assembly|interface issue|instrumentation|scm pressure transmitter|vendor|final inspection error|PT com resíduo metálico.|2932 - SCAN SENSE AS - PO 47456833-8
ZF|P6000064909|14/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|SCM - Document Updates|HFT procedure updated with referance.
ZF|100036232|25/01/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|fks quality system issues|product realization|documentation requirement|input requirements missing|Incorrect purch of products and serices|Traceability List - no ref. to  SEM615
ZF|P6000074156|14/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|coating plating|coating defect|scm hyd mech components|outer can|other causes damage|no noncompliance|Chipping of coating on outercan.|Chipping of coating on outercan.
ZF|100017278|27/07/2009|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|marking|unknown info damage_desc|scm|scm|other causes damage|qn cancelled|Test problems|No failure in marking
ZD|P6000088751|22/02/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|other defect|part lost|scm|scm|vendor|missing parts|(SS) WEL GWF SCM missing internal O-ring|SCM missing internal O-ring
ZF|P6000029772|17/10/2012|priority 3 |Q3|ENGIE|NORTH SEA|ATCO NOPT NOTE NOCO|other defect|functional|scm|scm|engineering|engineering error|Stuck strainer for silicone compensator|Marginal materials specified
ZF|P6000102687|04/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|drawing error|scm sem el opt component|sem cable & wiring|engineering|continuous improvement|Re assemble FO on ESRS with clips|Design improved  ref ECN6158709
ZB|P1000004979|10/07/2009|priority 3 |Q1|BP|GOM|NOCO ATCO NOTE|other defect|physical|scm electrical|other scm electrical|materials stores|improper packaging & storage|Coffee cups used as protection caps|shipping procedures not followed.
ZE|P6000074156|22/07/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|process procedure ineffective|SCM LP  & HP Overpressure S #401- ORANGE|unknown info root_cause
ZB|100064910|11/05/2016|priority 1 |Q1|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|other defect|functional|scm|scm|other causes damage|cause not found|Åsgard GC 179117 SCM electronic failure|unknown info root_cause
ZB|7104670|30/03/2010|priority 1 |Q1|STATOIL|NORTH SEA|ATCO NOPT NOTE NOCO|test|function|scm|scm|qa qs qi|operator error|Warranty claim 108 - SCM & FCM failure|Removed cover on couplings prior to inst
ZF|P7000008275|23/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|assembly|interface issue|electric products|electrical connector|vendor|final inspection error|Fio do Conector Eletrico Danificado|1021-Teledyne Oil & Gas - SN1009662-544
ZF|P6000065886|01/11/2011|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|engineering|lack of training|Transposition error on cable lables|Wrong wiring of transformer
ZF|100049000|21/06/2011|priority 1 |Q3|BP|GOM|NOPT NOTE ATCO NOCO|machining|false cut|scm|scm|vendor|programmer error|Investigate Coupler Rotation-BPAT SCM 29|Investigate Coupler Rotation-BPAT SCM 29
ZF|P6000105708|21/08/2014|priority 2 |Q3|EXXONMOBIL|GOM|NOCO NOTE NOPT ATCO|design|specification error|scm|scm|engineering|engineering error|SRMDT  Julia SN 05  Redesign/ Reconfig|Insufficient silicone comp  ref. RCA
ZB|100048038|26/05/2010|priority 3 |Q1|CHEVRON|unknown info region|ATCO NOCO NOTE|damage|damage during testing|control system topside hydraulic eq.|hydraulic power unit (hpu)|vendor|equipment malfunction|SCM 5 Compensator Bladder|Eratic HPU pressure
ZE|P6000031350|27/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|physical damage|scm|scm|causes for improvement|process procedure not being followed|Damaged wire|Wires stretched  incorrect lifting opera
ZF|P7000039672|14/03/2016|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|damage|damage from corrosion|scm hyd mech components|locking mechanism|vendor|coating defect|Oxidação nos Dogs|unknown info root_cause
ZF|P6000093498|18/06/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|engineering|engineering error|LLP WOCM Communication Failure|SW issue  Followed up in QN200473687
ZF|P6000088751|31/05/2016|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|function|scm|scm|engineering|engineering error|Wiring Error.|RCA to be performed in ZE QN 200501401
ZF|P6000077638|12/12/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|assembly|interface issue|electronic boards|dhi|qa qs qi|final inspection error|unknown info notification_desc|unknown info root_cause
ZF|P6000039844|02/02/2011|priority 1 |Q3|SHELL|unknown info region|ATCO NOTE NOCO NOPT|other defect|functional|scm|scm|engineering|continuous improvement|(SS)SCM - Product Improvement|unknown info root_cause
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P6000104111|09/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|procedure error|Another PN for test equipment to be used|Another PN for test equipment to be used
ZF|100026328|12/09/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|other defect|functional|electronic boards|other eletronic boards|other external causes|customer error responsibility|Avaria em leitura de PT's|MMR SCM_ Manutenção corretiva
ZF|P7000039672|16/01/2018|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOPT NOTE|damage|damage during testing|scm hyd mech components|sem bracket|assembly|procedures not followed|MMR - Locking Mechanism Failure|Technician did not follow procedure
ZF|P6000055605|22/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|scm|scm|engineering|procedure error|SEM B absolute pressure 1200 mBar|SEM pressure not completely drained
ZF|P6000113559|05/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|drawing error|scm|scm|engineering|dwg error|ECs in top oriented 180degrees wrong|Designer error  followup ZE200379221
ZD|P6000084242|08/02/2012|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|other defect|physical|scm|scm|intercompany|kongsberg|(SS)INCORRECT PARTNUMBER|INCORRECT PARTNUMBER
ZF|P6000037215|26/11/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|design|drawing error|electric products|transformer modules|engineering|specification error|Gjøa manifolds|Engineering failure.
ZF|100035013|17/08/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO|test|component error|scm sem el opt component|other scm sem el opt components|other causes damage|cause not found|Fiber fault on D3 SEM A  Ormen Lange|Fiber fault on D3 SEM A  Ormen Lange
ZF|100037965|16/05/2014|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|damage|wear & tear|scm|scm|engineering|procedure error|Damage to SCM can and locking mechanism|1000Nm may be too high to unlock the SCM
ZF|P6000079984|16/12/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|assembly|interface issue|scm|scm|assy|missing parts|Assy/Exxon/SCM/Missing Alignment Pin|Missing Alignment Pin
ZF|P6000064909|07/06/2011|priority 3 |Q3|TOTAL|NORTH SEA|NOCO NOTE ATCO|assembly|assembled incorrectly|scm el opt components|scm wiring|test|operator error|Wiring error and cut on hose from EC5|Wires were switched. Human error.
ZF|P6000068924|11/04/2012|priority 3 |Q3|TOTAL|unknown info region|ATCO NOCO NOTE NOPT|other defect|functional|test and transportation|other scm test & transport equipment|engineering|procedure error|Current reading in ST outside acc. crit.|Reference current not same as measured
ZB|P6000101955|02/12/2016|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTE NOCO|design|procedure error|object types to eng matl class|scm|engineering|dbi error|SCM  SEM B failure|See QN 200405310
ZB|P6000064909|21/06/2013|priority 1 |Q1|TOTAL|NORTH SEA|ATCO NOTE NOCO|other defect|functional|fks quality system issues|product realization|other causes damage|cause not found|Laggan Claim 27 - SCM 05|No fault found on SCM
ZF|P6000055605|28/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Leakage test failed|Too high and unstable leakage from DCV
ZF|100020278|30/06/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|design|specification error|computer system software|etu sw|other causes damage|qn cancelled|ETU SW Configuration Error on SCM|Due to no feedback/response from Houston
ZF|100017278|05/04/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|machining|surface finish error|scm hyd mech components|outer can|assy|improper handling|Nickel Coating of sealing area|Damaged during maintenance
ZD|7102969|08/12/2014|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|coating plating|incorrect colour coating|scm hyd mech components|outer can|vendor|specification not followed|Outer can painted surfaces.|unknown info root_cause
ZF|P6000104111|18/08/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|engineering|engineering error|Update KS200e SW for Egina|Com. functionality which was not cons.
ZF|P6000068912|07/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|assembled incorrectly|scm|scm|assy|operator error|Loose bolts on outercan SCM.|Operator distracted during an operation
ZB|100056261|28/10/2009|priority 2 |Q1|MURPHY|WEST AFRICA|NOTE NOCO ATCO|test|function|scm electrical|other scm electrical|other causes damage|cause not found|SEM Common Alarm|SEM Common Alarm
ZF|P6000088751|09/01/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|100049000|23/06/2010|priority 2 |Q3|BP|GOM|NOCO NOTE ATCO NOPT|documentation|incorrect certificates records|scm|scm|test|missed operation|Missing sign offs|Missing signature.
ZF|P6000102687|14/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|damage during assembly|scm sem el opt component|el opt penetrator (insert)|assy|damaged during assembly|Fiber Penetrator broken|Occasional opr failure
ZF|P6000105710|13/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Conector satt 180 grader feil|Wrong position on EC (rotation)
ZF|P6000116166|08/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|leakage (fluid)|scm hyd mech components|control valve|engineering|engineering error|Too high internal leakage|Leakage in CV - requesting CAR
ZF|P6000039844|07/10/2009|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|design|drawing error|scm|scm|engineering|dwg error|Gumusust SCM for marking inconsistencies|Marking inconsistence on GA drawing
ZF|P7000039672|09/08/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|component error|scm hyd mech components|check valve|vendor|equipment malfunction|Check Valve out of Acceptance Criteria|1242 - HTS maskinteknikk as
ZB|100048038|05/01/2010|priority 3 |Q1|CHEVRON|unknown info region|NOTE NOCO ATCO|test|function|scm hydraulic|other scm hydraulic|test|damaged during testing|Comm Board For Analog Input Burnt|Comm Board For Analog Input Burnt
ZF|P7000000897|29/08/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|function|scm|scm|test|incorrect set up testing|Hyperbaric Test BC-10 SCM 29.|QN aberta para registrar desvio de leitu
ZF|P7000039672|09/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|part lost|scm el opt components|el. connector|engineering|missing parts|Missing screws in ODI Connector|1021 - Teledyne Oil and Gas
ZE|P6000105710|25/02/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|test|missed operation|scm|scm|variance|enhance process|Missing log files|Workshop check list will be created
ZF|P6000069056|30/10/2017|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|electrical|other specify in comments|object types to eng matl class|scm|other causes damage|cause not found|Silicone leakage on EC7 - Concession Req|Unknown. No visible damage.
ZF|P7000039672|26/01/2015|priority unknown info priority|Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|component error|instrumentation|scm pressure transmitter|vendor|equipment malfunction|Incorrect reading of pressure transducer|unknown info root_cause
ZF|P6000074156|20/02/2012|priority 3 |Q3|SHELL|GOM|NOTE NOCO ATCO NOPT|damage|damage during testing|scm|scm|test|incorrect set up testing|Blow out in hyperbaric 3  West Boreas|Blow out in hyperbaric 3
ZF|P6000098616|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000058949|21/05/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|design|dbi error|scm|sem|engineering|engineering error|Wrong length on screws to the elcan.|Incorrect screw lenght used in BOM
ZF|100031223|04/02/2013|priority 3 |Q3|STATOIL|NORTH SEA|NOPT NOTE NOCO ATCO|damage|damage from corrosion|scm hyd mech components|outer can|projects|material error|SCM  corrosion betw.can and connector|unknown info root_cause
ZB|100020278|22/04/2008|priority 2 |Q1|unknown info customer_name|unknown info region|NOCO NOTE|test|function|scm hydraulic|other scm hydraulic|other causes damage|cause not found|Host SCSSV's failed to close ESD Level 2|unknown info root_cause
ZB|100020562|20/08/2009|priority 3 |Q1|BP|GOM|NOTE NOCO ATCO|assembly|assembled incorrectly|scm hydraulic|other scm hydraulic|other causes damage|no noncompliance|Plug on LP Vent to Sea|Plug on LP Vent to Sea
ZD|P6000079433|05/09/2013|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|damage|damage due to handling|scm|scm|other causes damage|cause not found|Part/Cert Issue|VL FINAL INSPECTION ERRORVL CLARIFICATION REQUIREDNVL HANDLING DAMAGENVL CAUSE NOT KNOWN
ZF|P6000088614|19/09/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|damage during testing|object types to eng matl class|scm|test|damaged during testing|Water in silicone sample|Leaking connection in hyperbaric tank
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|unknown info root_cause
ZE|P6000080678|07/10/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|unknown info damage_group_desc|unknown info damage_desc|scm hyd mech components|other mechanical components|causes for improvement|process procedure not being followed|(CDM) Xena - SCM Adapters not supplied|Missing Adapters
ZF|P7000024900|08/05/2012|priority 1 |Q3|SHELL|unknown info region|ATCO NOTE NOCO NOPT|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|packaging handling|Manifold Block Arranhado|unknown info root_cause
ZD|100055600|10/06/2008|priority 3 |Q2|TALOS|GOM|NOCO NOTE NOPT ATCO|documentation|missing certificates records|scm|scm|vendor|specification not followed|No DBI Available|No DBI Available
ZF|P6000043714|04/05/2011|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|function|scm sem el opt component|baseplate w. penetrator (w or w o pcon)|test|incorrect set up testing|Noncomformance to HFT acceptance|Nonconformance to HFT acceptance
ZF|P6000105542|15/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|leakage (gas)|scm hyd mech components|accumulator|other causes damage|cause not found|Low pressure in accumulator after FAT|No gas leakage can be re-produced
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000105710|13/02/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|assembled incorrectly|scm|scm|assy|operator error|Connector satt 180 grader feil|Wrong position on EC (rotation)
ZE|P6000123495|01/10/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|test|component malfunction|LP supply PT1A reading high - Kulite|LP supply PT1A reading high - Kulite
ZF|P7000016420|14/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|test|missed operation|test and transportation|other scm test & transport equipment|test|incorrect set up testing|SRT SCM P-55 SN 07|lab test box com fio solto
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|sem|causes for improvement|process procedure not being followed|CAR 3 RCA Actions_2 from RPT10033107|Wrong part number installed
ZB|100035013|05/10/2015|priority 4 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|functional|customer compliant|noncompliance to customer requirement|other external causes|customer error responsibility|Warranty Claim69-D3SCM#21 Malfunctioning|D3 SCM#21 Malfunctioning fiber
ZF|P7000016420|30/06/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|imension (tolerance)|scm|scm|vendor|design error|Protection Ring não monta|unknown info root_cause
ZF|100048038|23/04/2008|priority 2 |Q3|CHEVRON|WEST AFRICA|NOCO NOTE NOPT|assembly|unknown info damage_desc|scm|sem|other causes damage|no noncompliance|Wrong type of DHI 117 used in AGB S/N 32|No failure  Misunderstanding
ZB|100018082|22/11/2013|priority 1 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO|assembly|imension (tolerance)|scm|scm|vendor|material error|Warranty claim 246 - SCM on Mikkel B-3H|unknown info root_cause
ZF|P6000083428|20/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|component error|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT 04 Over acceptance criteria|PT 04 outside of the acceptance criteria
ZF|100037427|01/12/2010|priority 2 |Q3|TOTAL|WEST AFRICA|NOCO NOTE ATCO|documentation|procedure process error|scm|scm|engineering|dwg error|Error in FAT procedure and GA DWG|DWG error
ZF|P7000039672|30/05/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly|assembled incorrectly|scm el opt components|scm wiring|assy|operator error|Pt's Invertidos|unknown info root_cause
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|NOPT NOCO NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|P7000039672|15/10/2015|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|component error|electronic boards|other eletronic boards|intercompany|kongsberg|Leitura incorreta do PT 22|unknown info root_cause
ZF|P7000024900|01/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|leakage (gas)|scm hyd mech components|check valve|other causes damage|damage from wear and tear|VAZAMENTO DE PRÉ-CARGA|unknown info root_cause
ZF|P6000067533|08/01/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|materials stores|improper packaging & storage|SCM Modules stored outside with no PSM|Improper storage
ZF|P6000055213|06/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|other defect|functional|scm hyd mech components|control valve|test|incorrect set up testing|concession on SCM MK II  615  PROD/WIXT|test equipment is unstable
ZE|100020562|14/08/2009|priority 2 |Q3|BP|GOM|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|fks quality system issues|product realization|causes for improvement|lack of resources|CAR 4 RCA Actions_2 from RPT10033107|unknown info root_cause
ZF|P7000016420|05/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT-61|Kulite semiconductor
ZF|P7000001621|21/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|CVLP #19 com grande vazamento|unknown info root_cause
ZE|P6000091085|11/08/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|unknown info damage_group_desc|unknown info damage_desc|computer system software|basis e sw|causes for improvement|documentation|Child CAR - OWIRS - Deadman sequence|unknown info root_cause
ZF|100001156|31/01/2014|priority 4 |Q3|STATOIL|NORTH SEA|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|engineering error|Wrong Max Voltage in documentation.|Wrong voltage on GA drawing
ZF|P7000016420|09/11/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|electronic boards|dhi|engineering|procedure error|Exception code recieved when testing DHI|Config file error
ZB|100048038|14/12/2009|priority 3 |Q1|AGBAMI|unknown info region|NOCO NOTE ATCO|test|function|scm electrical|dhi pcbs|test|damaged during testing|AGB20 32E1 SSGI cards 1 & 2 SEM A fault|AGB20 32E1 SSGI cards 1 & 2 SEM A fault
ZF|P6000065886|14/09/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|design|dbi error|scm|scm|engineering|engineering error|Revision change. Flowmeter adapter plate|dwg updated see ECN 6102516
ZB|100017997|05/05/2010|priority 1 |Q1|BP|unknown info region|NOPT ATCO NOTE NOCO|test|component error|scm|scm|other causes damage|damage from wear and tear|BPTH IWOCS 4 excess fluid|BPTH IWOCS 4 excess fluid
ZF|P6000105542|10/12/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO|test|function|scm hyd mech components|hydraulic manifold adapter plate|intercompany|dunfermline|SCM manifold block failure - SN15|Wrong welding pin defined for man. block
ZF|P6000081371|17/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|coating plating|coating defect|scm hyd mech components|outer can|other causes damage|cause not found|Outer Can coating error - run marks|Coating on OC has marks from Hyperbaric
ZF|P6000104116|27/04/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|damage|damage during assembly|scmmb|other electric components|assy|damaged during assembly|Child QN on DIU  (P6000104116)|unknown info root_cause
ZF|P7000016420|26/10/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|assembly|interface issue|scm hyd mech components|hydraulic manifold adapter plate|vendor|specification not followed|Sem Bracket x Manifold Block|Bosch - manifold block
ZF|7103382|25/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|obsolescence issue:&|not available|scm|scm|engineering|dbi error|Incomplete BOM for PN 7103382|unknown info root_cause
ZE|P6000113559|15/05/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|design|drawing error|scm|scm|projects|documentation error|ECs in top oriented 180degrees wrong|Wrong EC orientation on drawings.
ZF|7101172|14/07/2011|priority 3 |Q3|STATOIL|NORTH SEA|NOTE NOPT NOCO ATCO|damage|wear & tear|scm el opt components|el. connector|other causes damage|damage from wear and tear|Tronick coupler broken|Wear and Tear
ZF|P6000069056|12/10/2012|priority 1 |Q3|STATOIL|NORTH SEA|NOTE NOCO NOPT ATCO|test|missed operation|scm|scm|test|incorrect set up testing|High pressure on return line|RCA will be followed up in ZE 200288773
ZF|P6000065886|22/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|missed operation|scm|scm|test|tooling|Testing not according to HFT procedure|Testing not according to HFT procedure
ZF|P6000138873|19/11/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|damage|damage during assembly|scm|scm|test|damaged during testing|SCM - El.connenector clash.|mounting base EC orinted 90 degrees wron
ZF|7101401|24/11/2014|priority 2 |Q3|PETROBRAS|unknown info region|NOTE NOCO NOPT ATCO|other defect|physical|scm hyd mech components|outer can|service :|damaged during installation|MMR - Outer Can Colapsed|unknown info root_cause
ZF|P7000039672|27/05/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|assembly|physical damage|scm hyd mech components|hydraulic manifold adapter plate|other causes damage|cause not found|Danos em área de vedação  Manifold Block|unknown info root_cause
ZF|P7000039672|19/12/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|function|scm hyd mech components|other hydraulic components|vendor|operator error|PT com Mau funcionamento.|unknown info root_cause
ZF|100056443|14/04/2010|priority 1 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOPT NOTE|test|function|scm|scm|qa qs qi|final inspection error|SCM B Communication failure to WOCS.|Ref ServiceNotification 300305855
ZE|P6000088604|20/10/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|qa qs qi|operator error|(CDM) Accumulator Leakage CVX XT SCM #02|unknown info root_cause
ZF|P6000063531|10/03/2015|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE NOPT|test|missed operation|scm|scm|test|operator error|Powered sem with too high voltage|Wrong test procedure used
ZF|P7000024191|26/02/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|functional|scm sem el opt component|other scm sem el opt components|engineering|continuous improvement|Frequência da SEM B fora do especificado|unknown info root_cause
ZF|7102643|30/10/2008|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE NOPT|other defect|functional|scm|scm mounting base (scm|test|missed operation|Scm not locked in skid.|SCM not properly secured acc. tp procedu
ZF|P6000103208|25/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZF|P6000065886|14/12/2010|priority 2 |Q3|ENI|NORTH SEA|ATCO NOPT NOCO NOTE|design|dbi error|scm|scm|engineering|dbi error|Parts missing in BOM.|Missing qty of parts BOM.
ZF|100049000|22/03/2011|priority 2 |Q3|BP|unknown info region|NOTE NOPT ATCO NOCO|raw material|defects in material|hydraulic products|coupler|other causes damage|no noncompliance|Hydraulic Coupler/Port on SCM|Hydraulic Coupler/Port on SCM
ZD|100049000|20/09/2010|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|design|dbi error|scm|scm|engineering|engineering error|No DBI|No DBI
ZF|P7000000897|21/11/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|function|scm hyd mech components|check valve|test|operator error|check valves|erro na execução do teste
ZD|P6000122574|21/08/2018|priority 1 |Q2|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|test|leak|object types to eng matl class|scm|assembly|trash burr contamination|FLM Kit not holding pressure|unknown info root_cause
ZF|P6000055605|24/01/2012|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|design|procedure error|common misc general|software|engineering|ecn change|incorrect  values|Incorrect Values
ZF|P6000121268|12/01/2015|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|test|function|scm|scm|test|incorrect set up testing|Range of Pressure Transmitter (PT)|Range of Pressure Transmitter (PT)
ZB|100049000|07/04/2010|priority 2 |Q1|BP|GOM|NOTE NOPT ATCO NOCO|damage|wear & tear|scm mech w mb|locking mechanisms|other causes damage|damage from wear and tear|DSCM16 Seized Locking Mechanism|DSCM16 Seized Locking Mechanism
ZF|P6000079984|20/08/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|wrong test procedure used|electric products|electrical components|test|incorrect set up testing|Canbus error|Too high capacitance in ext.wiring
ZF|140-141-004|28/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|damage|damage during transport|scm el opt components|el. connector|materials stores|damaged during transport|Conector de Base danificado|Danos no Conector El. ODI 4pin
ZD|P6000100953|31/10/2013|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|damage|damage during transport|scm|scm|other causes damage|no noncompliance|crates damaged in trainsit|crate damage during in transit
ZE|P6000104115|02/09/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO|test|leakage (fluid)|scm|scm|qa qs qi|operator error|Water inside the SRM|Assembly error
ZD|P6000090632|11/06/2015|priority unknown info priority|Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|function|scm|scm|vendor|second tier supplier issue|(SS) EDP WOCM no bootp call on PSDA Card|Software  issue
ZB|100051269|20/12/2017|priority 2 |Q1|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|project|project requested unfinished shipment|scm|scm|documentation requirement|other specify in comments|No extra cost for witness 3rd part|Contractual
ZF|P6000042970|24/09/2009|priority 2 |Q3|TOTAL|WEST AFRICA|NOTE NOCO NOPT ATCO|design|unknown info damage_desc|topside products|n a sw|engineering|unknown info cause_desc|Error in ESS config file|unknown info root_cause
ZF|P6000055605|13/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|function|scm|scm|engineering|engineering error|Lost communication after switching|Procedure failure  OMM60059036
ZF|P7000024191|14/03/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|test omitted|scm|scm|test|incorrect set up testing|Man. Global #19 Can Bus & Serial Line|Lab test box with problem.
ZF|100020278|14/07/2011|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|other defect|functional|scm|scm|test|incorrect set up testing|HFT-0000020573 needs to be updated|Software update
ZD|P6000145982|26/06/2018|priority 1 |Q2|unknown info customer_name|unknown info region|NOTE ATCO NOCO|damage|damage during transport|object types to eng matl class|scm|coating|damage|Damage issue|VL DAMAGED DURING TRANSPORT
ZF|P7000039672|26/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm hyd mech components|other mechanical components|other causes damage|cause not found|protection ring ovalizada|unknown info root_cause
ZF|P6000073687|13/06/2012|priority 3 |Q3|FRADE B.V.FRADE PH II|unknown info region|NOCO NOPT ATCO NOTE|damage|damage during testing|scm hyd mech components|hydraulic coupler|assy|damaged during assembly|HC2 and HC6 coupler damaged|Damaged female couplers due to SCM TS
ZF|P6000121393|04/06/2015|priority 4 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|test|missed operation|scm|scm|test|missed operation|Holstein 1 SCM Dekit|250J40 Missed RIT of SCM
ZB|P6000101955|22/12/2015|priority 2 |Q1|unknown info customer_name|unknown info region|NOTE NOCO ATCO|other defect|functional|scm hyd mech components|other hydraulic components|other causes damage|cause not found|Tyrihans SCM 05 Warranty 173957|unknown info root_cause
ZF|P7000016420|17/01/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|missed operation|scm|scm|test|incorrect set up testing|SRT SCM P-55 SN 13|lab test box com fio solto
ZF|P6000055198|05/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|coating plating|painting defect|scm hyd mech components|outer can|vendor|coating defect|White layer on outercan|White layer on outercan.
ZF|P6000104116|28/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|machining|surface finish error|scm hyd mech components|other mechanical components|vendor|specification not followed|O-ring surface too rough|Sealing surface sandblasted follow-up QN
ZF|P7000024191|03/10/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|test|test omitted|scm|scm|test|incorrect set up testing|SRT Global 10 can bus and Serial Line S2|Lab test box with problem.
ZF|P7000016420|28/04/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|assembly|interface issue|scm hyd mech components|baseplate|vendor|specification not followed|Furo da Base Plate não conforme|Revestimento na rosca
ZF|P6000064911|03/10/2018|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|change deviation request|process substitution request|object types to eng matl class|scm|other causes damage|planning error|Cust. Dev. - Issues with SRM 4|unknown info root_cause
ZB|100020278|18/11/2009|priority 2 |Q1|EXXONMOBIL|unknown info region|NOTE ATCO NOCO|test|function|scm|scm|test|damaged during testing|Comm's fault w/SCM 16|Comm's fault w/SCM 16
ZF|P6000105542|26/02/2015|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOCO NOTE ATCO|welding|miscellaneous|scm|scm|vendor|specification not followed|Hydraulic fluid in silicone oil sample|Flatness on man. block not acc. to spec
ZF|P6000123495|29/09/2016|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|test|component error|object types to eng matl class|scm|test|component malfunction|LP supply PT1A reading high - Kulite|Follow up in ZE QN:200513101
ZF|P6000093498|16/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm sem el opt component|sem cable & wiring|engineering|engineering error|Communication problem on HS CAN BUS|Internal HS Can-bus was not terminated
ZF|P7000039672|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|design|dbi error|scm|scm|engineering|ecn change|ECN 7058839 - P7000017839|ECN 7058839 - P7000017839
ZF|100049000|10/06/2011|priority 3 |Q3|BP|GOM|NOPT NOTE NOCO ATCO|assembly|interface issue|hydraulic products|coupler|other causes damage|no noncompliance|Coupler verification for free rotation|Coupler verification for free rotation
ZF|P6000042968|22/03/2010|priority 1 |Q3|TOTAL|WEST AFRICA|NOPT NOTE ATCO NOCO|documentation|procedure process error|scm|scm|test|damaged during testing|SCM software failure|Downloaded software was not correct
ZF|P6000125392|24/11/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOPT NOCO|machining|surface finish error|scm hyd mech components|sem can|vendor|specification not followed|El can not according to specification|Surface threatment not acc. to DBI.
ZF|100035013|01/11/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOTE|assembly|assembled incorrectly|scm|scm|test|operator error|Screws not torqued according to spec.|unknown info root_cause
ZF|100033987|09/04/2017|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT ATCO NOTE|damage|wear & tear|scm hyd mech components|other hydraulic components|test|wear and tear|CR: CIDV not to be overhauled acc. to PO|CIDV not to be overhauled.
ZE|P6000080343|03/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO|unknown info damage_group_desc|unknown info damage_desc|scm|scm|manufacturing engineering|me programming|Investigation of metal found in flowmete|Cause for metal chip not found.
ZF|100058509|31/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|specification error|topside products|n a sw|engineering|specification error|LLOG GC448 fast scan issue|unknown info root_cause
ZF|P6000129784|06/04/2017|priority 1 |Q3|LLOG|unknown info region|NOCO NOPT NOTE ATCO|test|damaged during testing|scm sem el opt component|other scm sem el opt components|test|incorrect set up testing|High voltage on ethernet lines|Applied 540VAC to ethernet wires
ZF|P6000065886|27/12/2010|priority 2 |Q3|ENI|NORTH SEA|NOCO NOTE ATCO|other defect|functional|electronic boards|main boards cpu & i o|engineering|continuous improvement|CPU600 improving startup on long umbilic|Recommended Improvement (QN200189637)
ZF|P6000090632|19/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOPT NOCO ATCO|test|function|scm|scm|engineering|continuous improvement|Limited to 12 can nodes on PSD|Limitation in Firmware on TRITON module
ZB|7102643|28/07/2012|priority 3 |Q1|unknown info customer_name|unknown info region|ATCO NOCO NOTE|other defect|functional|scm|scm|engineering|engineering error|Avbrutt SCM ops. etter feil anbefal. FMC|Wrong info. from onshore support
ZF|P6000058949|03/11/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|test|function|electronic boards|dhi|vendor|clarification|Unstable DHI 119 on SEM A|Wrong ID on DHI sensor-sim in use
ZF|P6000042308|01/12/2009|priority 3 |Q3|TULLOW|WEST AFRICA|NOTE ATCO NOPT NOCO|test|unknown info damage_desc|scm|scm|test|operator error|Return system pressurized to 345 bar|Manual Isolation valve on ATS was Closed
ZF|P7000008275|23/06/2014|priority 1 |Q3|PETROBRAS|unknown info region|NOCO ATCO NOTE|damage|damage during testing|scm hyd mech components|compensator|test|operator error|MMR - HW Leakage through Strainer|unknown info root_cause
ZD|P6000057855|17/02/2010|priority 3 |Q2|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|test|function|electronic boards|other eletronic boards|engineering|continuous improvement|Communication failure SEM|improper anchorage of intrconnect wires
ZF|P7000039672|18/06/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|component error|instrumentation|scm pressure transmitter|vendor|equipment malfunction|PT-13 com leitura incorreta|SCAN-SENSE AS
ZE|P6000105708|20/08/2014|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|unknown info damage_group_desc|unknown info damage_desc|topside products|topside electronic module (tem)|intercompany|kongsberg|RECALL ( Warranty) SRM's|RECALL (WARRANTY ) SRM'S
ZF|P7000024900|19/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|assembly|physical damage|scm hyd mech components|other hydraulic components|vendor|material error|Strainer cisalhado|2241 - RUSH MASKINERINGSENTER A/S
ZB|100001156|21/07/2012|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|leakage (fluid)|scm|scm|other causes damage|damage from wear and tear|Leak in SCM|Damage from Wear and Tear
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOCO NOPT NOTE|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000098616|23/04/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|change deviation request|process substitution request|scm|scm|other causes damage|no noncompliance|Additional endurance test|No SCM failure detected in extend. test
ZB|P6000043122|08/09/2010|priority 2 |Q1|TOTAL|unknown info region|NOPT NOTE NOCO ATCO|coating plating|painting defect|scm el opt components|el. connector|test|damaged during testing|Coating is damaged|Coating damaged
ZB|100033987|24/01/2008|priority 1 |Q1|STATOIL|NORTH SEA|NOCO NOPT NOTE ATCO|test|function|scm|scm|engineering|engineering error|WARRANTY CLAIM 156 SEM RAM failure|FMC guarantee acceptance
ZF|100037427|03/06/2013|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|damage|damage during assembly|scm|scm|assy|damaged during assembly|wiring stressed during outercan assembly|Damaged wire due accidental opr. errror
ZD|P6000042308|16/06/2016|priority 3 |Q2|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|coating plating|painting defect|scm hyd mech components|outer can|vendor|specification not followed|Not coated per drawing specifications|Not coated per drawing specifications
ZF|100059660|14/02/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO NOPT|test|test omitted|scm|scm|other external causes|customer error responsibility|SCM not mobilized acc. to FMC procedure|Re-evaluation of SOW due to need date
ZF|P7000000897|13/10/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|cleanliness|scm|scm|other causes damage|cause not found|Flushing do compensador|unknown info root_cause
ZF|P6000079984|22/06/2012|priority 3 |Q3|EXXONMOBIL|NORTH ATLANTIC|NOCO NOPT ATCO NOTE|damage|damage during testing|scm|scm|test|damaged during testing|marks on basplate mounted ECs|Damaged due to incorrect EC pos on SCMTS
ZF|P7000024191|10/12/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|interface issue|scm hyd mech components|baseplate|other causes damage|cause not found|Base plate danificada|Sem evidência da causa
ZF|P6000079433|12/07/2018|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|test|missed operation|object types to eng matl class|scm|test|other specify in comments|Missing CPI DHI simulator|CPI test equipment missing
ZF|100017278|18/03/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|missed operation|scm|scm|test|tooling|Testing not according to customer PO|Lack of test equipment
ZF|100056443|11/01/2010|priority 3 |Q3|EDISON/EDF|NORTH SEA|NOPT NOTE NOCO ATCO|test|function|scm|scm mounting base (scm|other causes damage|qn cancelled|Communication problems|No failure in SCM  see attachment
ZF|P6000068924|12/06/2012|priority 2 |Q3|TOTAL|unknown info region|ATCO NOTE NOCO NOPT|test|function|scm|scm|other causes damage|cause not found|Loose HC`s in baseplate.|RCA to be followed up in ZE 200296914.
ZF|100056261|14/08/2009|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOTE NOCO|damage|damage during assembly|scm|scm|other causes damage|unknown info cause_desc|Damaged Supply Flowmeter O-ring|Damaged Supply Flowmeter O-ring
ZE|P6000104116|15/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|machining|surface finish error|scm|scm|causes for improvement|process procedure ineffective|Damaged sealing surface|No routines for cleaning clamping
ZF|P7000000229|27/11/2012|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|other defect|functional|scm sem el opt component|other scm sem el opt components|vendor|maintenance|Teste Funcional SCM Frade #09|MMR SCM
ZB|100051269|09/01/2017|priority 2 |Q1|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|electrical|functional|scm|scm|other external causes|customer error responsibility|Communication failure between SCM og ALD|Statoil didnt wish t cont troubleshootin
ZF|P6000058949|07/12/2010|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|design|drawing error|scm|scm|engineering|dwg error|SCM outercan drawing error|DWG error
ZE|100035118|07/06/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|unknown info damage_group_desc|unknown info damage_desc|hydraulic products|other hydraulic products|qa qs qi|final inspection error|(SS)WEL Enfield SCM|Torqued was too tight
ZF|100020562|24/09/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|test|leakage (fluid)|scm hyd mech components|control valve|other external causes|customer error responsibility|High LP DCV Leakage Rate|unknown info root_cause
ZF|P7000039672|03/03/2017|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO DLFL NOCO|design|dbi error|object types to eng matl class|funnel_fabrication|other causes damage|qn cancelled|ECN 6209019  PN P6000075566|Error-documentation
ZF|P6000063531|06/11/2014|priority 3 |Q3|STATOIL|NORTH SEA|NOPT ATCO NOCO NOTE|test|leakage (fluid)|scm hyd mech components|control valve|vendor|equipment malfunction|Vigdis VEPIII rebuild Leakage|DCV failed leakage test after overhaul
ZF|7104670|22/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|missed operation|scm|scm|test|missed operation|FSM Test in FAT not performed|CPI test equipment not available
ZB|100049000|28/04/2010|priority 3 |Q1|BP|GOM|ATCO NOTE NOCO|raw material|defects in material|scm electrical|dhi pcbs|other causes damage|damage from wear and tear|DC121A DSCM 02 DH Gauges Readings Freeze|Gauges Readings Freeze
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOTE ATCO NOCO NOPT|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZB|100056443|13/05/2013|priority 3 |Q1|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|test|function|scm|scm|other external causes|customer error responsibility|DT Communication problems with SCM/EHXT|Time consuming operation.
ZF|P6000123495|07/10/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|component error|electronic boards|main boards cpu & i o|engineering|engineering error|Problem with microcontroler 4 on SEM B|Board to be investigated in new ZE QN
ZE|P6000104116|02/06/2014|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|unknown info damage_group_desc|unknown info damage_desc|scm|scm|causes for improvement|documentation|Add guide pins to ensure correct assembl|Continously improvement
ZF|P7000001843|25/04/2014|priority 3 |Q3|PETROBRAS|unknown info region|ATCO NOCO NOTE NOPT|damage|damage during testing|electronic boards|other eletronic boards|test|damaged during testing|MMR - Problems with APSD2 card - Mex.#11|unknown info root_cause
ZF|P6000031350|03/12/2008|priority 1 |Q3|STATOIL|NORTH SEA|NOTE NOPT ATCO NOCO|assembly|assembled incorrectly|scm|scm|other causes damage|qn cancelled|Wrong- hex-head instead of cap-screw|No error - screw change with ECN 6044068
ZF|P6000103208|09/10/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE|other defect|functional|electronic boards|main boards cpu & i o|other causes damage|no noncompliance|Lost communicaton for a while in Burn in|External Cause  no SCM failure
ZF|P7000016420|27/09/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE NOPT|assembly|assembly not serialized|scm|scm|qa qs qi|documentation error|Parafusos sem lote marcado|Parafusos sem lote marcado
ZF|P6000132097|27/09/2018|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|marking|marking content error|object types to eng matl class|scm|other causes damage|cause not found|Defect found in shipping inspection|unknown info root_cause
ZB|100017997|01/03/2010|priority 2 |Q1|BP|GOM|NOTE NOPT ATCO NOCO|raw material|hardness out of tolerance|wocs control module (wocm) mech. w mb|outer can|other causes damage|damage from wear and tear|Roughness out of tol. on EC int. seal|Roughness out of tol. on EC int. seal
ZE|P7000039672|17/02/2017|priority 4 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|coating|incorrect surface preparation|Outer can coating damage|Poor surface preparation for coating
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000126219|29/09/2017|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE NOCO ATCO NOPT|test|function|scm hyd mech components|other hydraulic components|fabrication shop personnel|operator error|Missing test of new PT found during FI|misunderstanding between two technicians
ZF|100056443|28/09/2010|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Documentation error VEGA|Correction of old procedures
ZF|P6000073613|28/06/2013|priority 3 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|assembled incorrectly|scm|scm|engineering|specification error|Spare 4-20mA sensors not in wiring list|Wiring list was not updated
ZB|P6000029747|10/09/2012|priority 2 |Q1|unknown info customer_name|unknown info region|NOTI ATCO NOPR|other defect|functional|scm sem el opt component|other scm sem el opt components|other external causes|customer error responsibility|Gjøa Claim 057 SCM 015|SEM failure - out of warranty
ZF|P7000024900|24/10/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOCO ATCO NOTE|test|component error|electronic boards|dhi|intercompany|kongsberg|LEITURA INCORRETA DHI113|unknown info root_cause
ZF|P6000079984|03/07/2012|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE ATCO NOPT|damage|damage during testing|scm test stand|other mechanical components|test|damaged during testing|Marks on baseplate mounted ECs|Wrong angle on connector wing on SCMTS
ZF|P7000001621|26/05/2010|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|documentation|incorrect user documentation (customer)|scm|scm|assy|lack of training|Inspeção de Recebimento|DEsmontagem sem RIRC
ZF|100052701|06/03/2008|priority 2 |Q3|STATOIL|NORTH SEA|NOPT NOTE ATCO NOCO|raw material|incorrect material|scm|scm|vendor|material error|Replacement of DCV's|DCV/COV with Cobalt pilot ball
ZF|P7000039672|29/08/2014|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOPT NOCO NOTE|damage|damage during transport|scm hyd mech components|other hydraulic components|vendor|damage during transport|Arranhão na área de vedação|1242 - HTS maskinteknikk as
ZF|P6000108542|09/03/2016|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|leakage (fluid)|scm|scm|test|damaged during testing|283912979Z Failed Leakage Test|Failed Leakage Test
ZF|P7000016420|14/07/2011|priority 1 |Q3|unknown info customer_name|unknown info region|NOTE NOPT ATCO NOCO|test|function|electronic boards|dhi|vendor|equipment malfunction|Failure on TPT AR read.|MIKROKRETS
ZF|P6000042968|26/08/2013|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOTE|change deviation request|process substitution request|scm|scm|engineering|continuous improvement|Additional endurance test|EET performed.
ZF|P7000000897|24/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOTE NOCO|assembly|interface issue|scm hyd mech components|control valve|materials stores|improper packaging & storage|Change over com desvios|unknown info root_cause
ZF|P7000024191|23/10/2012|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOPT NOCO|assembly|wrong part assembled|scm|scm|other causes damage|cause not found|Coupler de supply fora da revisão atual|ECN não implementada
ZF|P6000068770|09/08/2015|priority 2 |Q3|unknown info customer_name|unknown info region|NOTE ATCO NOCO|documentation|incorrect user documentation (customer)|scm|scm|engineering|ecn change|Non conforming master data  PSM|unknown info root_cause
ZF|P6000088626|31/07/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOTE NOCO NOPT ATCO|design|specification error|scm sem el opt component|sem cable & wiring|engineering|engineering error|EngineeringErr:Missing earth conductors.|Missed to include earth wiring in LST
ZF|P6000074156|17/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|test|function|scm|scm|vendor|equipment malfunction|(SS) DHI card update issue|DHI card update issue
ZF|P6000031350|20/03/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO|test|function|electronic boards|dhi|engineering|engineering error|IWIS DHI-board set to wrong baudrate|Missing MOC at change of baud rate
ZF|100052388|07/03/2013|priority 2 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO|design|dbi error|scm hyd mech components|hydraulic coupler|engineering|continuous improvement|BOM and ICP update on old system scm's|New part required for each mobilization
ZF|P6000107991|22/04/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT ATCO NOCO NOTE|test|function|electronic boards|dhi|vendor|clarification|no status codes in  Line status|Follow-up in QN 200376395
ZB|7101172|02/11/2009|priority 4 |Q1|STATOIL|NORTH SEA|NOTE NOPT NOCO|other defect|functional|scm|sem|vendor|material error|SCM 19 GFA  J-3H  AI-card SEMB malfunc.|Power supply failure  DC/DC converter
ZF|P6000121268|15/10/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO NOTE NOPT ATCO|other defect|physical|scm hyd mech components|baseplate|other causes damage|planning error|Missing Baseplate|Base plate not avaliable on stock
ZF|100020562|02/08/2010|priority 3 |Q3|BP|GOM|NOTE NOCO NOPT|marking|no marking|scm|scm|assy|lack of maintenance|Mark all necessary ports on BPTH SCMs|Mark all necessary ports on BPTH SCMs
ZE|P6000091085|22/08/2016|priority 4 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|unknown info damage_group_desc|unknown info damage_desc|object types to eng matl class|scm|variance|enhance process|Child CAR - OWIRS Deadman sequence|unknown info root_cause
ZB|100027228|01/12/2011|priority 1 |Q1|STATOIL|NORTH SEA|NOCO ORAS NOPT ATCO NOTE|documentation|procedure process error|scm sem el opt component|sem mech. components|engineering|procedure error|Critical error with E-3H QDV|unknown info root_cause
ZF|P6000083395|25/04/2012|priority 3 |Q3|TOTAL|unknown info region|NOPT NOCO ATCO NOTE|documentation|procedure process error|scm|scm|engineering|procedure error|Test of WLD missing in inhouse procedure|Test of WLD missing in In-house / FAT
ZF|P6000028371|27/01/2009|priority 3 |Q3|SHELL|GOM|ATCO NOTE NOCO NOPT|damage|damage during assembly|scm|scm|other causes damage|qn cancelled|short circuit wires on outercan|PN fabricated before the MOC approval
ZF|P6000080733|01/04/2014|priority 4 |Q3|STATOIL|NORTH SEA|NOTE NOCO ATCO|test|leakage (fluid)|scm|scm|engineering|engineering error|Leakage on Silicone Compensator Bladder|Leakage in bladder  blister
ZF|P6000110380|03/03/2014|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|test|function|electronic boards|eth.net items|other causes damage|cause not found|ESRS610 Failure Alarm during Syst Test|No need to open the SCM  continue tests
ZF|P6000042969|24/02/2015|priority 3 |Q3|unknown info customer_name|unknown info region|NOPT NOTE NOCO ATCO|machining|gd&t (geometric dimension&tolerance)|scm hyd mech components|other mechanical components|vendor|specification not followed|Groove/slot dim out of tolerance|One part found out of tolerance.
ZF|P7000039672|19/09/2013|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|leakage (fluid)|scm hyd mech components|hydraulic manifold adapter plate|vendor|final inspection error|Vazamento no Manifold block PS#15|123643 - BOSCH REXROTH  LTDA
ZF|P6000065886|03/01/2011|priority 2 |Q3|unknown info customer_name|unknown info region|NOPT NOTE ATCO NOCO|assembly|interface issue|scm hyd mech components|hydraulic tubing|engineering|continuous improvement|Forslag til endring på fremtidige ordre|Continuous Improvement
ZF|P6000043766|26/05/2009|priority 3 |Q3|PETROBRAS|GOM|NOTE ATCO NOCO NOPT|assembly|wrong part assembled|scm|scm|assy|operator error|Wrong PN and SEM address on nameplate|FMC Assy: Operator Error
ZB|100017997|20/04/2009|priority 3 |Q1|BP|GOM|ATCO NOPT NOCO NOTE|other defect|physical|wocs control module (wocm) hydraulic|other wocm hydraulic|engineering|engineering error|WSCM Saltwater Ingress|WSCM Saltwater Ingress below EC connecto
ZF|100049000|30/11/2010|priority 2 |Q3|BP|GOM|NOPT NOCO ATCO NOTE|design|dbi error|scm|scm|engineering|ecn change|Class 1 ECN 6083510|Class 1 ECN 6083510
ZF|100030542|20/04/2015|priority 1 |Q3|CNR|unknown info region|ATCO NOTE NOCO|test|leakage (fluid)|scm|scm|vendor|specification not followed|SCM bladder found with defect|Vendor : Specification not follow
ZF|P7000039672|25/07/2014|priority 1 |Q3|unknown info customer_name|unknown info region|NOCO NOPT NOTE ATCO|design|dbi error|scm|scm|engineering|ecn change|ECN 6164886 - P7000039672|unknown info root_cause
ZF|P6000066700|22/08/2011|priority 1 |Q3|HOUSTON STOCKING V2|unknown info region|NOTE ATCO NOCO NOPT|damage|damage during assembly|scm|scm|test|damaged during testing|SCM MK II E  150  HOUSTON STOCK V2|Wrong config  in ext realer terminat box
ZD|P6000123882|14/01/2015|priority 3 |Q2|unknown info customer_name|unknown info region|NOCO ATCO NOTE|marking|marking content error|scm|scm|vendor|specification not followed|Assy/Hess/SCM/Misprint Nameplate|Misprint Nameplate
ZF|P7000024191|21/05/2012|priority 1 |Q3|unknown info customer_name|unknown info region|ATCO NOTE NOCO NOPT|test|missed operation|scm|scm|test|incorrect set up testing|SRT SCM GLOBAL SN 01|Lab test box with problem.
ZF|100049000|09/03/2011|priority 2 |Q3|BP|GOM|NOTE ATCO NOPT NOCO|assembly|interface issue|hydraulic products|hydraulic manifold kit|other causes damage|no noncompliance|Hydraulic Coupler/Port on SCM|Hydraulic Coupler/Port on SCM
ZF|P6000104114|06/11/2014|priority 3 |Q3|unknown info customer_name|unknown info region|NOCO ATCO NOPT NOTE|assembly|assembled incorrectly|scm sem el opt component|sem cable & wiring|engineering|ecn change|Mising wires in wiring kit|ECN process missed to update stock
ZF|P6000058949|06/06/2013|priority 3 |Q3|STATOIL|NORTH SEA|ATCO NOCO NOTE|documentation|procedure process error|scm|scm|engineering|continuous improvement|Gullfaks drawing|Information in drawing improved.